APPROVED BLD ENG PLN BLD RESUB 1-Arch and Site PlanPROJECT NOTES PROJECT DESCRIPTION REPAIR AND REPLACE DECK IN KIND REGULATORY 1. ALL MATERIALS, WORKMANSHIP, DESIGN AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS AND THE FOLLOWING APPLICABLE CODES USED IN THE DESIGN: - 2018 INTERNATIONS RESIDENTIAL CODE (IRC) - 2015 WA STATE ENERGY CODE, RESIDENTIAL PROVISIONS 2015 INTERNATIONAL FIRE CODE (IFC) 2. A SEPARATE PERMIT MAY BE REQUIRED FOR PLUMBING, ELECTRICAL AND/OR MECHANICAL WORK AS APPLICABLE. 3. A COPY OF THE APPROVED PERMIT PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION. ARCHITECTURAL 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE BUILDING AND SITE. IN EVENT OF ANY DISCREPANCY BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS, OR BETWEEN CONTRACT DOCUMENTS THEMSELVES, THE GENERAL CONTRACTOR SHALL NOTIFY THE DESIGNER PRIOR TO PROCEEDING WITH WORK. 2. DIMENSIONS TO FACE OF CONCRETE, FRAMING OR AS NOTED. 3. IN THE EVENT OF FIELD ERRORS OR OMISSIONS, THE GENERAL CONTRACTOR SHALL NOTIFY DESIGNER AND MAKE NO REPAIRS WITHOUT APPROVAL. 4. DO NOT SCALE CONTRACT DOCUMENTS. 5. CONTRACTOR SHALL PROVIDE WORK AND WORKMANSHIP IN A WAY TO MEET ALL APPLICABLE CODES. 6. CONTRACTOR SHALL COORDINATE ALL TECHNICAL TRADES AND SUBCONTRACTORS TO VERIFY MEETING THEIR REQUIREMENTS AS PART OF THEIR CONTRACT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. 8. ALL WASTE AND REFUGE CAUSED IN CONNECTION WITH THE WORK SHALL BE REMOVED FROM THE PREMISES AND DISPOSED OF BY THE CONTRACTOR. THE PREMISES SHALL BE LEFT CLEAR AND CLEAN TO THE SATISFACTION OF THE OWNER. 9. CONTRACTOR SHALL DESIGN AND INSTALL SHORING AS REQUIRED TO PERFORM WORK. ENGINEERING, CONSTRUCTION, AND SAFETY OF THE SHORING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 10. CONTRACTOR TO TEST FOR LEAD IN PAINT AND ASBESTOS IN AREAS BEING WORKED ON AND REMOVE USING APPROPRIATE ABATEMENT METHODS IF NECESSARY. GUARDRAIL PROVIDE A GUARDRAIL WHERE THERE IS A VERTICAL DROP IN FLOOR SURFACE GREATER THAN 30". THE MIN HEIGHT OF THE GUARD SHALL BE 36" ABOVE WALKING SURFACE. OPENINGS IN THE GUARD SHALL NOT ALLOW A SPHERE OF 4" TO PASS THROUGH. SHALL BE ABLE TO WITHSTAND A 200 LB. LOAD IN ANY DIRECTION AT THE TOP OF THE GUARD. BUILDING INFORMATION EXISTING NEW DEMO SINGLE FAMILY STRUCTURE: 1 ST FLOOR 1240.5 BASEMENT 1095.5 DECK 367 280 367 TOTAL - 2,336 IMPERVIOUS SURFACE CALCULATIONS (E) HOUSE: 1320 SOFT (E) BRICK PATIO 215.4 SOFT (E) ASPHALT DRIVEWAY: 2445 SOFT (N) COMPOSITE DECK 367 SOFT (E) STAIRS & WALKWAY 308.25 SOFT TOTAL: 4655.65 SOFT: 42% PROJECT TEAM OWNER:/ APPLICANT TOM FINLAYSON & RACHEL CHAMBERLAIN 8825 SHELL PL., EDMONDS, WA 98026 P: 360.550.1550 tfinlayson@gmail.com STRUCTURAL ENGINEER: BASRI BASRI B2 STRICTURAL ENGINEERS 15306 61 ST. PI. NE KENMORE, WA 98028 p:425.296.2993 basri@b2engineers.com CONTRACTOR: Chris Stokley Outdoor Living Spaces NW PO Box 2776 Woodinville, WA 98072 p: 206-730-4955 chris@livingspacesnw.com LOT INFORMATION PARCEL: 00373600501503 ADDRESS: 8825 SHELL PLACE, EDMONDS, WA 98026 ZONING: 111 SINGLE FAMILY OCCUPANCY: RS-3 (FLAG LOT) LEGAL DESCRIPTION: Section 30 Township 27 Range 04 Quarter NW Subdivision ALDERWOOD MANOR NO 9 BILK 005 D-03 PTN LOT 15 BLK 5 SD PLAT DAF BEG NW COR LOT 8 PLAT OF SHELL PARK DIV NO 2 TH N ALG E LN SD PLAT OFSHELL PARK DIV NO 2 DIST 142.59FT TH E PLW N LN LOT 8 SD PLAT OF SHELL PARK DIV NO 2 DIST 90FT TH SWLY TAP ON N LN SD LOT 8 DIST 60FT E FR TPB DIST 145.70FT M/L TH W ALG N LN SD LOT 8 TO TPB A DIST60FT AKA LOT 1 CITY OF ED SP S-1-79 REC UND AFN 7905180212 TGW TH PTN LOT 9 PLAT OF SHELL PARK DIV NO 2 DAF COM NE COR SD LOT 9 SD PT BEING TPB TH S ALG E LN THOF 69FT TO SE COR THOF TH W ALG S LNTHOF 11.39FT TH N09*22 14E 69.93FT TO TPB PER SNO CO SCC NO 96-2-04875-3 PARCEL AREA: 11,103.65 SQ. FT. SEE GUARDRAIL NOTE IN PROJECT NOTES NEW 2X8 JOIST PER STRL. DECK MATERIALS: DECKING, CAP RAIL & FACIA: TREX COMPOSITE DECKING 4X4 RAIL POSTS & TOP RAIL: KNOT CEDAR 2X HORIZONTAL RAILINGS: CLEAR CEDAR SPACE[ <4" APART NEW DECK STRUCTURE (E) HOUSE PER SRTL. NO CHANGE NEW 6X6 POST PER SRTL. CEDAR OR PRESSURE TREATED WOOD (E) GRAVEL UNDER DECK WEST ELEVATION 3 'SCALE: 1/4" V-0" I� I GRANULAR ROCK WA 4NIT YIYG r L_5_OCr SNITS N SECTION LIST OF DRAWINGS A- ARCHITECTURAL Al COVERSHEET: SITE PLAN, DECK PLAN, ELEVATION, & SECTION S- STRUCTURAL S-0 GENERAL NOTES & SPECIFICATIONS S-1 FRAMING PLAN & DETAILS APPROVED BY PLANNING Oct 21 2021 ------------ RS-8 N Y Zone Corner Flag Setbacks: Required Actual North 7.5 12.2 South 7.5 80 East .---- -- ' 7.5 ,---------- 25.3 -----------, 7.5 --------- 23.3 West ----------- �----------- ' 25 NC Height -- 35' II I I I I _ _ _ - _ _ _ _ - _ _ _ - ill !! id DEMO (E) DECK. it I !I REBUILD IN SAME I LOCATION. SIZE REDUCTION !I - II FROM 367 SF TO 280 SIF !61 ill it I Wood lattice panels for additional privacy here and along the south edge of the deck. Architectural ER/CONTRACTOR RESPONSIBLE FOR LOCATING N SITE UTILITIES. RELOCATION/REVISION TO ANY TILITIES MAY REQUIRE A SEPERATE PERMIT. Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE DECK PLAN crrni P- IIA" _ V_nl. 10' STORM SEWER UTILITY EASEMENT AFN 2070861 NOTE: INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. ALL DISTURBED AREAS TO BE COMPOST AMMENDED PER 2014 SWMMWW BMP T.5.13 NOTE: TYP EROSION HAZARD PER CRITICAL AREA DETERMINATION (CRA20180194) SHELL PLACE APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work DECK Address 8825 SHELL PL Owner FINLAYSON Approved Date 10/14/2021 Building Official !7 W. W v4ALcLic Permit Number BLD2021-1206 I co ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF EDMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. z LU w 0 Cie LU Cie LL_ ca V) w iD a w Cie 90.00' (E) BRICK PATIO 1 Q 8'-0" w I- EXISTING HOUSE o ire M M 1 cl, REWILD DECK �I I NEW FOOTPRINT 280SF. SPACED 1 DECK WITH W7" LANDSCAPE / BELOW 1coc, N: 5� 1 EXIST4fQ ASPHALT 1 � IVEWAY I 5c' 11- ° ° ----- co co co CD ° N° 7'-6" SETBACKS: ALL SIDES 1 10'60.00' N (E) 8"CONCRETE SEWER MAIN SITE PLAN SCALE: 1" = 20' IMPERVIOUS SURFACES: THERE ARE NO NEW IMPERVIOUS SURFACES BEING ADDED IN THIS APPLICATION. Special Inspections required for this project: 1) Soils 2) Construction and Installation of the Pipe Piles I 1 1 I ' 1 1 W Z N Lu 0 LU H Q 0 (E) STAIRS AND WALKWAY U Z (E) 6" PVC SIDE SEWER Q N 0 O (E) 1" CU WATER LINE U w F- N (E) ASPHALT DRIVE EASEMENT U_ w > 0 Cie H Q OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE Z 0 ENGINEERING DIVISION APPROVED AS NOTED 10/27/2021 ***No stormwater management system required at this time. If new and replaced impervious surfaces equals 2000sgft or greater, a stormwater management system will be required per City standards.*** RESUB Oct 11 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z O 0 Cfl N Q 00 � J UJ Z -V� � Lim Z0 ZWo 0 W - QW J to Q W 0- W J W W � LO N Q 00 00 W I- W Q = J U D!f Lu W C) 0 U Al ol