REVIEWED RESUB1 BLD2021-1248+Structural_Analysis_or_Calculations+3.15.2022_2.32.13_PM+2739179Kimley)))Horn Smartlink Group, LLC. Kevin Fraleigh, P.E. 11232 1201h Ave NE, Suite 204 3875 Embassy Pkwy #280 Kirkland, WA 98033 Akron, OH 44333 (406) 749-0046 (216) 505-8256 Date: March 2, 2022 K-H Project #: KHCLE-7686 Comprehensive Structural Analysis Report Carrier Designation: T-Mobile Site ID: SE0451A Sprint Legacy ID: SE52XC156 Client Site Number: THE EXECUTIVE HOMEOWNERS ASSOCIATION T-Mobile Project: SPRINT RETAIN Analysis Criteria: Code Requirements: TIA-222-H, 2018 IBC, 2018 WSBC Ultimate Wind Speed: 98 mph w/ 0" Ice Wind Speed w/ Ice: 30 mph w/ 1" Ice Site Data: 1001 5th Ave S, Edmonds, WA 98020, Snohomish County Latitude 47.46944054' N, Longitude 122.21542540' W T-Mobile Market: SEATTLE WA 40.5 ft Structure Height w/ (6) Mount Pipes 41.5 ft — Mount Centerline Elevation Ms. Kristina Lampert, Kimley-Horn and Associates, Inc. is pleased to submit this "Comprehensive Structural Analysis Report" to determine the structural integrity of the above mentioned building. The purpose of the analysis is to determine acceptability of the structure stress level. Based on our analysis we have determined the mount and shroud anchorage, under the following load case, to be: Existing+Proposed: Shroud Anchorage Mount Anchorage 44.0% Pass 31.0% Pass This analysis utilizes an ultimate 3-second gust wind speed of 98 mph as required by the 2018 Washington State Building Code. Applicable Standard references and design criteria are listed in Page 2 - Analysis Criteria. Structural analysis prepared by: Eric Embick, P.E. Respectfully submitted by: Michael Oglesby, P.E. Lic. #51372, Exp. 05/16/2023 Kimley-Horn and Associates, Inc. COA #954 T-Mobile Site ID: SE01451A Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION KH Job # KHCLE-7686 Page 2 ■ INTRODUCTION At the request of Smartlink Group, Kimley-Horn and Associates, Inc. performed a structural analysis of the existing rooftop structure located in Edmonds, WA. The purpose of the analysis is to determine the adequacy of the building to support the loading configuration outlined in Appendix A (Tower Analysis Summary Form), pursuant to the referenced standards. ■ ANALYSIS CRITERIA The analysis utilizes RISA 3D, v. 17.0.1, an industry -standard finite element analysis program used to create an elastic three-dimensional model considering second -order effects per ANSI/TIA-222 requirements. The program calculates member stresses for various loading cases and selected output from the analysis is included in the appendices. Note: This analysis does not contain a structural analysis of the existing building as insufficient information was provided in the supporting documents. Site specific building information and an analysis will be required in order to perform a full building analysis. All anchorage checks provided are based on assumptions of the building construction material and thickness. Should any information be provided which does not agree with the assumptions made in this calculation, Kimley-Horn shall be contacted for a re -review of the site. TIA-222 Revision: TIA-222-H Risk Category: II Ultimate Wind Speed: 98 mph Exposure Category: C Topographic Factor at Base: 1.00 Topographic Factor at Mount: 1.00 Ice Thickness: 1.0 in Wind Speed with Ice: 30 mph Seismic Structure Class: D Seismic S.: 1.282 Seismic Si: 0.451 SUPPORTING DOCUMENTATION Information on the current building geometry, member sizes, foundation dimensions, soil properties, and antenna loading was obtained from the sources listed below. It is assumed that all information provided to Kimley-Horn & Associates, Inc. is accurate. In the absence of information to the contrary, we assume the structure has been properly erected and maintained per the original design drawings and the capacity has not significantly changed from the "as new" condition. Mount Mapping Not Provided Mount Design Site Pro 1 WMA300, dated 01/10/2012 Perfect Vision PC-PMLSL2-4-B, dated 01/28/2019 Site Photos Kimle -Horn, Project #: KHCLE-7682, dated 03/05/2021 Construction Drawings Clearwire, Rev A, dated 03/19/2006 Previous Structural Analysis Fullerton, dated 04/01/2015 Shroud Design NB Engineering Services, Project#: 100111, dated 03/09/2022 Loading Data T-Mobile RFDS SE01451A Version 1, dated 02/21/2021 T-Mobile Site ID: SE01451A Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION KH Job # KHCLE-7686 Page 3 • RESULTS The tables below show a maximum usage summary for each group of components in the structure. The usage of a component is the ratio of force in the member compared to its calculated capacity. A more detailed report of member usages can be found in the appendix at the end of this report. Usages greater than 100% indicate where the force in the member exceeds its capacity. Usages up to 105% are considered acceptable per industry standard practice. Structure Usages: Structure Controlling Result Component Usage Shroud Anchorage 44.0% Pass Mount Anchorage 31.0% Pass ■ CONCLUSIONS AND RECOMMENDATIONS Per our structural analysis, the structure has been found to pass. The building can support the referenced loading in accordance with the structural strength requirements of ANSI/TIA-222-H and 2018 Washington State Building Code. This analysis does not contain a structural analysis of the existing building as insufficient information was provided in the supporting documents. Site specific building information and an analysis will be required in order to perform a full building analysis. The usages acquired are based largely on assumptions of the existing building. T-Mobile Site ID: SE01451A KH Job # KHCLE-7686 Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION Page 4 ■ ASSUMPTIONS AND LIMITATIONS Note: This analysis does not contain a structural analysis of the existing building as insufficient information was provided in the supporting documents. Site specific building information and an analysis will be required in order to perform a full building analysis. All anchorage checks provided are based on assumptions of the building construction material and thickness. Should any information be provided which does not agree with the assumptions made in this calculation, Kimley-Horn shall be contacted for a re -review of the site. This report is not a condition assessment of the structure and it's foudnation; It is an engineering analysis based upon the theoretical capacity of the structure. Unless told otherwise, we assume the building to be in "like new" condition. It is the responsibility of our client and the buliding owner to verify that the building section modeled and loading considered is accurate. If these assumptions are not accurate, Kimley-Horn & Associates, Inc. should be notified immediately to perform a revised analysis. This analysis assumes all antenna mounts are adequate to support the existing and proposed loads. It is the carrier's responsibility to ensure antenna mount meets the structural requirements of ANSI/TIA-222. Kimley-Horn & Associates, Inc. did not analyze antenna supporting mounts as part of this structural analysis report. All services are performed, results obtained, and recommendation made in accordance with generally accepted engineering principles and practices. Kimley-Horn & Associates, Inc. is not responsible for the conclusions, opinions and recommendations made by others based on the information in this report. Kimley-Horn makes no warranties, expressed or implied in connection with this report and disclaims any liability arising from original design, material, fabrication, and section deficiencies or corrosion of the building. T-Mobile Site ID: SE01451A Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION KH Job # KHCLE-7686 Page 5 APPENDIX A Tower Analysis Summary Form Tower Analysis Summary Form General Info Site Name The Executive Homeowners Assoc. Sprint Legacy ID SE52XC186 T-Mobile Site ID SE01451A Date of Analysis 6/30/21 Company Performing Analysis I Kimley-Horn Tower Info Description Date Tower Type (G, SST, MP) Rooftop Tower Height (top of steel AGL) 41' Tower Manufacturer N/A Tower Model N/A Tower Design N/A Foundation Design N/A Geotech Report N/A Site Photos Kimley-Horn Project #: KHCLE-7682 2/5/2021 Previous Structural Analysis Fullerton 4/1/2015 Previous Modification Drawings N/A Foundation Mapping I N/A Steel Yield Strength (ksi) Pipe 135 Angle 136 Existing / Reserved Loading The information contained in this summary report is not to be used independently from the PE stamped tower analysis. Design Parameters Design Code Used TIA-222-H, 2018 IBC & ASCE 7-16 Location of Tower (County, State) Snohomish, WA Ultimate Wind Speed (mph) 98 Ice Thickness (in) 1 Risk Category (I, II, III, IV) II Exposure Category (B, C, D) C Topographic Category (1 to 5) 1 1 This report uses the Site Pro 1 WMA300 (dated 01/10/2012) and Perfect Vision PC-PMLSL2-4-B (dated 01/28/2019) and must be installed in order for the analysis results to be valid. This analysis does not contain a structural analysis of the existing building as insufficient information was provided in the supporting documents. Site specific building information and an analysis will be required in order to perform a full building analysis. Analysis Results % Maximum Usage) Existing + Proposed Condition Proposed Mount Anchor (%) 1 11.0% Proposed Shroud Anchor (%) I 29.0% Antenna L Mount Transmission Line Antenna Owner Mount Height (ft) Antenna CL (ft) Quantity Type Manufacturer Model Azimuth Quantity Manufacturer Type Quantity Model Size Internal / External Sprint 41.5 41.5 3 Panel Unknown Unknown 20/140/250 Unknown Pipe Mount 3 Hybrid 1-1/4" External Sprint 41.5 41.5 3 Panel Unknown Unknown 20/140/250 on same mounts Sprint 41.5 141.5 13 1 RRH jUnknown Unknown on same mounts Sprint 41.5 141.5 16 1 RRH I Unknown jUnknown on same mounts Note: All Loading shall be removed prior to the installation of the proposed equipment and have not been considered in this analysis. Proposed Loading Antenna M Mount Transmission Line Antenna Owner Mount Height (ft) Antenna CL (ft) Quantity Type Manufacturer Model Azimuth Quantity Manufacturer Type Quantity Model Size Internal / External T-Mobile 41.5 4 L , 3 Panel Nokia AEHC 00/140/250 Site Pro 1 WMA300 3 HCS 2.0 1-5/8" External T-Mobile 41.5 41.5 3 Panel Commscope FFVV-65A-R2-V1 20/140/250 on same mounts T-Mobile 41.5 41.5 3 RRH Nokia AHFIG on same mounts T-Mobile 41.5 41.5 3 RRH Nokia AHLOA on same mounts T-Mobile 141.5 141.5 12 ICOVP 1 Nokia I HCS 2.0 Breakout Pendant I I Ion same mounts Note: The proposed loading shall be installed in addition to the remaining existing/reserved equipment at the same elevation. T-Mobile Site ID: SE01451A Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION KH Job # KHCLE-7686 Page 6 APPENDIX B Risa Output Files Kimley-Horn and Associates, Inc. SK - 1 EJE SE01451A Mar 2, 2022 at 11:04 AM SE01451A.r3d Kimley-Horn and Associates, Inc. SK - 2 EJE SE01451A Mar 2, 2022 at 11:05 AM SE01451A.r3d Section Sets Mount Angle Mount Pipe Pipe -To -Pipe RIGID Kimley-Horn and Associates, Inc. SK - 3 EJE SE01451A Mar 2, 2022 at 11:06 AM SE01451A.r3d Kimley-Horn and Associates, Inc. SK - 4 EJE SE01451A Mar 2, 2022 at 11:07 AM SE01451A.r3d -36.59611 -36.59611 Loads: BLC 1, Dead Kimley-Horn and Associates, Inc. SK - 5 EJE SE01451A Mar 2, 2022 at 11:09 AM SE01451A.r3d X Y Member Code Checks Displayed (Enveloped) Results for LC 1, Summary: 1.01D + 1.OW Kimley-Horn and Associates, Inc. SK - 6 EJE SE01451A Mar 2, 2022 at 11:09 AM SE01451A.r3d Code Check ( Env ) No Cal > 1.0 .90-1.0 .75-.90 .50-.75 0-50 X Y Member Shear Checks Displayed (Enveloped) Results for LC 1, Summary: 1.01D + 1.OW Kimley-Horn and Associates, Inc. SK - 7 EJE SE01451A Mar 2, 2022 at 11:09 AM SE01451A.r3d Shear Check ( Env ) No Cal > 1.0 .90-1.0 .75-.90 .50-.75 0-50 111RISA A NEMETSCHEK COMPANY Company Kimley-Horn and Associates, Inc. Designer EJE Job Number Model Name SEO1451A Mar 2, 2022 11:10 AM Checked By: Hot Rolled Steel Properties I ahal F rksil (,. rksil Ni I Tharm !\l Fri F1 rlansiturk/ftARl Via1r1rksi1 Rv Fi Irksil Pt 1 A992 29000 11154 .3 .65 .49 50 1.1 65 1.1 2 A36 Gr.36 29000 11154 .3 .65 .49 36 1.5 58 1.2 3 A572 Gr.50 29000 11154 .3 .65 .49 50 1.1 65 1.1 4 A500 Gr.B RND 29000 11154 .3 .65 .527 42 1.4 58 1.3 5 A500 Gr.B Rect. 29000 11154 .3 .65 .527 46 1.4 58 1.3 6 A53 Gr.B 1 29000 11154 .3 .65 .49 35 1.6 60 1.2 7 Al085 1 29000 11154 .3 .65 .49 50 1.4 65 1.3 Hot Rolled Steel Section Sets I ahal Ghana Tama rlacinn 1 ist Mntarinl rlasinn A rin91 lux/ rinAl 177 rinAl .1 rinAl 1 Mount Angle L3X3X3 Beam None A36 Gr.36 T ical 1.09 .948 .948 .014 2 Mount Pie P2 STD Column None A53 Gr.B Typical 1.075 .666 .666 1.331 3 Pipe -To -Pipe PL6x3/8 Column None A53 Gr.B Typical 2.25 .026 6.75 .101 Joint Coordinates and Temperatures I ohol Y rinl V rinl 7 rinl T- rm r)nf-h Crnm rlinn 1 N 1 0 -6 0 0 2 N2 0 6 0 0 3 N3 0 -6 40 0 4 N4 0 6 40 0 5 N5 3 0 0 0 6 N6 3 0 40 0 7 N7 0 0 0 0 8 N8 0 0 40 0 9 N9 13 0 -3 0 10 N10 13 0 43 0 11 N11 13 0 37 0 12 N12 13 0 3 0 13 A1T 16 0 37 0 14 A1B 16 0 3 0 15 N15 13 0 19 0 16 RRH 10 0 19 0 17 N 17 3 0 -3 0 18 N18 3 0 43 0 19 N21 13 0 6 0 20 N22 13 0 34 0 21 N21A 3 0 6 0 22 N22A 3 0 34 0 Member Primary Data I hel I Inint I Inint K Inint RntnteMenl Centinn/Chine Time rleeinn 1 ict KAnterinl rlecinn Rnlec 1 M1 N4 N3 180 Mount An le Beam None A36 Gr.36 Typical 2 M2 N2 N1 180 Mount An le Beam None A36 Gr.36 Typical 3 M3 N10 N9 Mount Pie Column None A53 Gr.B Typical 4 M4 N11 A1T RIGID None None RIGID Typical 5 M5 N8 N6 RIGID None None RIGID T ical 6 M6 RRH N15 RIGID None None RIGID Typical 7 M7 N7 N5 RIGID None None RIGID Typical 8 M8 N12 Al B RIGID None None RIGID Typical 9 M9 N18 N17 Mount Pie Column None A53 Gr.B Typical 10 M10 N22 N22A 90 -Pipe-To-Pipe Column None A53 Gr.B Typical RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 1 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 IIRISAoblgner Number : EJE Che11:1cAM ked By: A NEMETSCHEK COMPANY Model Name SE01451A Member Primary Data (Continued) Label I Joint J Joint K Joint Rotate de Section/Shape Type Design List Material Desi n Rules 11 M11 N21 N21A 90 Pi e-To-Pi e Column None A53 Gr.B Typical Basic Load Cases RI (' nacrrinfinn rafannni X (:rauifv V (;ravifv 7 (:ravifv _Ininf Pnin# nicfrihuf Aran(KAa Cnrfnra/PlafaAA/alll 1 Dead DL -1 4 2 Dead of Ice RL 4 6 4 Structure Wind (0) None 12 5 Structure Wind (30) None 12 6 Structure Wind (45) None 12 7 Structure Wind (60) None 12 8 Structure Wind (90) None 12 9 Structure Wind (12... None 12 10 Structure Wind (13... None 12 11 Structure Wind (15... None 12 12 Structure Wind w/.. None 12 13 Structure Wind w/.. None 12 14 Structure Wind w/.. None 12 15 Structure Wind w/.. None 12 16 Structure Wind w/.. None 12 17 Structure Wind w/.. None 12 18 Structure Wind w/.. None 12 19 Structure Wind w/.. None 12 20 Antenna Wind (0) None 8 21 Antenna Wind (30) None 8 22 Antenna Wind (45) None 8 23 Antenna Wind (60) None 8 24 Antenna Wind (90) None 8 25 Antenna Wind (120) None 8 26 Antenna Wind (135) None 8 27 Antenna Wind (150) None 8 28 Antenna Wind w/ I.. None 8 29 Antenna Wind w/ I... None 8 30 Antenna Wind w/ L. None 8 31 Antenna Wind w/ I... None 8 32 Antenna Wind w/ I... None 8 33 Antenna Wind w/ I... None 8 34 Antenna Wind w/ I.. None 8 35 Antenna Wind w/ I... None 8 36 Seismic X ELX 4 6 37 Seismic Y ELY 4 6 Load Combinations rlaerrinfinn Cn P C RI (`Far RI (`Far RI ('Gar RI r Far RI r Far RI r Far RI r`Far RI r`Far RI rFar RI (`Far 1 ■ 1 ��-m�m�---------------- ��-m®m�m�-------------- m + 1.0WO �o�m®momo�w�w�w�w�w�w�w m.2D �o�m®ommm�w�w�w�w�w�w�w RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 2 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 11 RISA JobIgner Number : EJE ChecOAM ked By: A NEMETSCHEK COMPANY Model Name SEO1451A Load Combinations (Continued) Description So..P... S... BLCFac..BLCFac..BLCFac..BLCFac..BLCFac..BLCFac..BLCFac..BLCFac..BLCFac..BLCFac... m101wrfrllz 1 ��-m®m�m�®�------------ 1.QEM • 1 �0-m®iiLY-------------- ®1 1 1 ® 1 • 1 1 ® 1 • 1 ® 1 •D + 1.QEM RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 3 111RISA A NEMETSCHEK COMPANY Company Kimley-Horn and Associates, Inc. Designer EJE Job Number Model Name SEO1451A Mar 2, 2022 11:10 AM Checked By: Joint Loads and Enforced Displacements (BLC 1 : Dead) .Inint I ahal I n M nirartinn Mannifiiriaf/Ih k-ftl (in raril (Ih*sA9/in Ih*sA9*inll 1 Al T L Z -36.596 2 Al B L Z -36.596 3 RRH L Z -83.8 4 RRH L Z -79.4 Joint Loads and Enforced Displacements (BLC 2: Dead of Ice) Inint I ahal I n M nirartinn Mannihiriaf(Ih k-ftl (in rari) (Ih*sA9/in Ih*sA9*in11 1 A1T L Z -124.272 2 Al B L Z -124.272 3 RRH L Z -39.038 4 RRH L Z -44.72 Joint Loads and Enforced Displacements (BLC 20 : Antenna Wind (0)) Joint Label L,D.M L Direction X Ma nitude Ib k-ft in sad Ib*sA2/in Ib *SA 2*in 1 A1T 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 21 : Antenna Wind (30)) Joint Label L.D.M L Direction X Ma nitude Ib k-ft in sad (lb *SA 2/in Ib *SA 2*in 1 A1T 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 22 : Antenna Wind (45)) Irvin+ I �hol 1 rl nA rlirortinn RA—nifi i i.rtih Ir-ffl !in r 41 /Ih*cA9/in Ih*cA9*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 23 : Antenna Wind (60)) Irvin+ I ho1 1 rl KA rlirortinn RA—nifi i.rtIh le-ftl !in r A\ /Ih*cA9/in Ih*cA9*in\1 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L y 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 4 111RISA A NEMETSCHEK COMPANY Company Kimley-Horn and Associates, Inc. Designer EJE Job Number Model Name SEO1451A Mar 2, 2022 11:10 AM Checked By: Joint Loads and Enforced Displacements (BLC 23 : Antenna Wind (60)) (Continued) Joint Loads and Enforced Displacements (BLC 24 : Antenna Wind (90)) _Inint l nhal 1 fl M Nrartinn Mannitiiriaf(Ih Ir-ftl (in raril (lh*cA9/in Ih*cAg*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 25 : Antenna Wind (120)) Inint I nhal 1 rl M Nrantinn Mannitwiaf(Ih i ftl (in raril (lh*cA9/in Ih*cAg*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 26 : Antenna Wind (135)) Inint I nhal 1 rl M nirarrtinn Mannihiriaf/lh i ftl (in raril (lh*sA9/in Ih*cAg*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 27 : Antenna Wind (150)) Inint I ahal I n M niractinn Mannihiriaf(Ih k-ftl (in raril (lh*sA9/in Ih*sA9*in11 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 28 : Antenna Wind w/ Ice (0)) Inint I ahal I n M niractinn Mannihiriaf(Ih k-ftl (in raril (Ih*sA9/in Ih*sA9*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 5 111RISA A NEMETSCHEK COMPANY Company Kimley-Horn and Associates, Inc. Designer EJE Job Number Model Name SEO1451A Mar 2, 2022 11:10 AM Checked By: Joint Loads and Enforced Displacements (BLC 28 : Antenna Wind w/Ice (0)) (Continued) Inint I ohal 1 h AA hirartinn NAnnniti inrllh Ie_f+l !in rnrll !Ih*cM/in Ih*cM*inll 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 29 : Antenna Wind w/ Ice (30)) .Inin# I Thal 1 rl NA rlirariinn RAnnniinrlar/Ih Ie-ftl tin raril /Ih*cA9/in Ih*cA9*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L y 0 Joint Loads and Enforced Displacements (BLC 30 : Antenna Wind w/ Ice (45)) Joint Label L D M Direction X Ma nitude Ib k-ftin sad (lb *SA 2/in Ib *SA 2*in 1 A1T L 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 ir 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 31 : Antenna Wind w/ Ice (60)) Joint Label L.D.M Direction L X Ma nitude Ib k-ftin sad (lb *SA 2/in Ib *SA 2*in 1 A1T 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 32 : Antenna Wind w/Ice (90)) _Inint I nhal I n M nirariinn RAnnnitiiriar/Ih Ir-ftl (in raril /Ih*cA9/in Ih*cA9*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L Y 0 5 RRH L X 0 6 RRH L Y 0 7 RRH L X 0 8 RRH L Y 0 Joint Loads and Enforced Displacements (BLC 33 : Antenna Wind w/Ice (120)) _Inint I nhal I n M nirartinn RAnnnitiiriar/Ih Ir-ftl (in raril /lh*cA9/in Ih*cA9*inll 1 A1T L X 0 2 A1T L Y 0 3 A1B L X 0 4 A1B L y 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 6 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 11 RISA JobIgner Number : EJE ChecOAM ked By: A NEMETSCHEK COMPANY Model Name SEO1451A Joint Loads and Enforced Displacements (BLC 33 : Antenna Wind w/ Ice (120)) (Continued) mint I h.1 1 rl nA r)irontinn KA—if—im tlh le-ftl tin —11 tIh*cA9/in Ih*cA9*inll 5 RRH L X 0 6 RRH L y 0 7 RRH L X 0 8 RRH L y 0 Joint Loads and Enforced Displacements (BLC 34 : Antenna Wind w/Ice (135)) Irvin+ I o1-1 1 h AA ni—tInn RA—nit—Jortlh Ir_f+l tin —IN tIh*cA7/in Ih*cA7*inll 1 A1T L X 0 2 A1T L y 0 3 A1B L X 0 4 A1B L y 0 5 RRH L X 0 6 RRH L y 0 7 RRH L X 0 8 RRH L y 0 Joint Loads and Enforced Displacements (BLC 35 : Antenna Wind w/ Ice (150)) Joint Label L.D.M L Direction X Ma nitude Ib k-ft in sad (lb *SA 2/in Ib *SA 2*in 1 A1T 0 2 A1T L y 0 3 A1B L X 0 4 A1B L y 0 5 RRH L X 0 6 RRH L y 0 7 RRH L X 0 8 RRH L y 0 IL Joint Loads and Enforced Displacements (BLC 36 : Seismic X) Joint Label L.D.M L Direction X Ma nitude Ib k-ft in sad (lb *SA 2/in Ib *SA 2*in 1 Al T 15.639 2 Al B I L I X 11WEF 15.639 3 RRH L X 35.811 4 RRH L X 33.93 Joint Loads and Enforced Displacements (BLC 37 : Seismic Y) Inint I hcl 1 r) nA hirontinn RA—itnricrtlh Ir-ftl tin —11 tIh*cA9/in Ih*cA9*inll 1 Al T L y 15.639 2 Al B L y 15.639 3 RRH L y 35.811 4 RRH L y 33.93 Member Point Loads Member Label Direction Ma nitude Ib k-ft Location in No Data to Print ... Member Distributed Loads (BLC 2: Dead of Ice) AAomhor I �hol rliron+inn Q+o.-+ AAon 4 —lorlh/f+ c-4 c Q+or+ I nno+innrin O/_7 Cn,4 I nno+innrin O/_7 1 M 1 Z -5.967 -5.967 0 0 2 M2 Z -5.967 -5.967 0 0 BEF 3 M3 Z -4.248 -4.248 0 0 4 M9 Z -4.248 -4.248 0 0 5 M 10 Z -6.352 -6.352 0 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 7 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 11 RISA Job1gner Number : EJE ChecOAM ked By: A NEMETSCHEK COMPANY Model Name SEO1451A Member Distributed Loads (BLC 2: Dead of Ice) (Continued) Member Label Direction Start Ma nitude Ib/ft ... End Ma nitude Ib/ft F... Start Location[in,%1 End Location in 6 Mil Z -6.352 -6.352 1 0 0 Member Distributed Loads (BLC 4: Structure Wind (0)) Mamhar I ahal nirartinn Start Mannifurlarlh/ft Fnrl Mannifurlarlh/ft F Start 1 nrntinnrin %1 Fnrl 1 nrnfinnrin 0M 1 M1 X -11.054 -11.054 0 0 2 M1 Y 0 0 0 0 3 M2 X -11.054 -11.054 0 0 4 M2 Y 0 0 0 0 5 M3 X -5.251 -5.251 0 0 6 M3 Y 0 0 0 0 7 M9 X -5.251 -5.251 0 0 8 M9 Y 0 0 0 0 9 M10 X 0 0 0 0 10 M10 Y 0 0 0 0 11 M11 X 0 0 0 0 12 M11 Y 0 0 0 0 Member Distributed Loads (BLC 5: Structure Wind (30)) Member Label Direction X Start Ma nitude Ib/ft ... End Ma nitude Ib/ft F... Start Location in % End Location in 1 M1 -7.18 -7.18 0 0 2 M1 Y 4.145 4.145 0 0 3 M2 X -7.18 -7.18 0 0 4 M2 Y 4.145 4.145 0 0 5 M3 X -4.547 -4.547 0 0 6 M3 Y 2.625 2.625 0 0 7 M9 X -4.547 -4.547 0 0 8 M9 Y 2.625 2.625 0 0 9 M10 X -4.787 -4.787 0 0 10 M10 Y 2.764 2.764 0 0 11 Mil X -4.787 -4.787 0 0 12 Mil Y 2.764 2.764 0 0 Member Distributed Loads (BLC 6: Structure Wind (45)) KA-k- i kni rliron+inn Ctnr+ RAnnni+i finnk/f+ C-4 KA-;+i v+orlhm C Ctnr+ 1-+innnn o%7 CnA I nn f;-r;n o%1 1 M1 X -3.908 -3.908 0 0 2 M1 Y 3.908 3.908 0 0 3 M2 X -3.908 -3.908 0 0 4 M2 Y 3.908 3.908 0 0 5 M3 X -3.713 -3.713 0 0 6 M3 Y 3.713 3.713 0 0 7 M9 X -3.713 -3.713 0 0 8 M9 Y 3.713 3.713 0 0 9 M10 X -7.816 -7.816 0 0 10 M10 Y 7.816 7.816 0 0 11 Mil X -7.816 -7.816 0 0 12 M11 Y 7.816 7.816 0 0 Member Distributed Loads (BLC 7: Structure Wind (60)) RA-hcr i h.1 ni-firm Qfnr+ RAnnni+, irinnF /fh Fnrl RAnnni+, irlorlh/fh r Ctmr+ 1-+innrin 0%1 Fnri I-finnrin 0%1 1 M1 X -1.382 -1.382 0 0 2 M1 Y 2.393 2.393 0 0 3 M2 X -1.382 -1.382 0 0 4 M2 Y 2.393 2.393 0 0 5 M3 X -2.625 -2.625 0 0 6 M3 Y 4.547 4.547 0 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 8 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 11 RISA Job1gner Number : EJE ChecOAM ked By: A NEMETSCHEK COMPANY Model Name SEO1451A Member Distributed Loads (BLC 7: Structure Wind (60)) (Continued) AAamhar I Thal nirartinn Curt AAnnnifi irlaflh/f+ Gnrl Unnnifi irlaflh/ft G Curt 1-tinnnn om Gnfl I-tinnrin om 7 M9 X -2.625 -2.625 0 0 8 M9 Y 4.547 4.547 0 0 9 M10 X -8.291 -8.291 0 0 10 M10 Y 14.36 14.36 0 0 11 Mil X -8.291 -8.291 0 0 12 M i i--= Y 14.36 14.36 0 0 Member Distributed Loads (BLC 8: Structure Wind (90)) KAamhar I nhal nirar+inn C+art Manniti irlaflh/ft Fnrl Manniti irlaflh/ft F C+art I nratinnrin 0/-1 Fnfl 1 nratinnrin 0/-1 1 M1 X 0 0 0 0 2 M1 Y 0 0 0 0 3 M2 X 0 0 0 0 4 M2 Y 0 0 0 0 5 M3 X -le-6 -1 a-6 0 0 6 M3 Y 5.251 5.251 0 0 7 M9 X -le-6 -1 a-6 0 0 8 M9 Y 5.251 5.251 0 0 9 M10 X -5e-6 -5e-6 0 0 10 M10 Y 22.108 22.108 0 0 11 Mil X -5e-6 -5e-6 0 0 12 Mil Y 22.108 22.108 0 0 Member Distributed Loads (BLC 9: Structure Wind (120)) Uamhar I ahal nirartinn Ctnrt Unnniti Irlaflh/ft Fnrl KAannitl lrianh/ff F Ctnrt 1 nratinnfin 0/ 1 Fnrl 1 nratinnrin 0/ 1 1 M 1 X 1.382 1.382 0 0 2 M 1 Y 2.393 2.393 0 0 3 M2 X 1.382 1.382 0 0 4 M2 Y 2.393 2.393 0 0 5 M3 X 2.625 2.625 0 0 6 M3 Y 4.547 4.547 0 0 7 M9 X 2.625 2.625 0 0 8 M9 Y 4.547 4.547 0 0 9 M10 X 8.291 8.291 0 0 10 M10 Y 14.36 14.36 0 0 11 Mil X 8.291 8.291 0 0 12 Mil Y 14.36 14.36 0 0 Member Distributed Loads (BLC 10 : Structure Wind (135)) AAomhor I �hol flironfinn Q+or+ AA-4 1-flh/ff Cnfl RAonnifi-4-nKm c Q+or+ I nno+innrin oil Cnfl I nno+innrin oil 1 M 1 X 3.908 3.908 0 0 2 M 1 Y 3.908 3.908 0 0 3 M2 X 3.908 3.908 0 0 4 M2 Y 3.908 3.908 0 0 5 M3 X 3.713 3.713 0 0 6 M3 Y 3.713 3.713 0 0 7 M9 X 3.713 3.713 0 0 8 M9 Y 3.713 3.713 0 0 9 M10 X 7.816 7.816 0 0 10 M10 Y 7.816 7.816 0 0 11 M11 X 7.816 7.816 0 0 12 M11 Y 7.816 7.816 0 0 Member Distributed Loads (BLC 11 : Structure Wind (150)) Member Label Direction Start Ma nitude Ib/ft ... End Ma nitude Ib/ft IF... Start Locationrin,%l End Location in % 1 M1 X 7.18 7.18 1 0 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 9 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 11 RISA JobIgner Number : EJE Chec0AM ked By: A NEMETSCHEK COMPANY Model Name SE01451A Member Distributed Loads (BLC 11 : Structure Wind (150)) (Continued) Member Label Direction Start Maanitudeflb/ft.... End Maanitudeflb/ft.F... Start Locationrin.%l End Locationrin.%l 2 M1 Y 4.145 4.145 0 0 3 M2 X 7.18 7.18 0 0 4 M2 Y 4.145 4.145 0 0 5 M3 X 4.547 4.547 0 0 6 M3 Y 2.625 2.625 0 0 7 M9 X 4.547 4.547 0 0 8 M9 Y 2.625 2.625 0 0 9 M10 X 4.787 4.787 0 0 10 M10 Y 2.764 2.764 0 0 11 Mil X 4.787 4.787 0 0 12 Mil Y 2.764 2.764 0 0 Member Distributed Loads (BLC 12: Structure Wind w/Ice (0)) Member Label Direction Start Maanitude[lb/ft.... End Maanitude[lb/ft.F... Start Locationrin.%l End Locationrin.%l 1 M1 X -.51 -.51 0 0 2 M1 Y 0 0 0 0 3 M2 X -.51 -.51 0 0 4 M2 Y 0 0 0 0 5 M3 X -.916 -.916 0 0 6 M3 Y 0 0 0 0 7 M9 X -.916 -.916 0 0 8 M9 Y 0 0 0 0 9 M10 X 0 0 0 0 10 M10 Y 0 0 0 0 11 M11 X 0 0 0 0 12 M11 Y 0 0 0 0 Member Distributed Loads (BLC 13 : Structure Wind w/Ice (30)) 1 Member Label M1 Direction Start Ma nitude Ib/ft ... End Ma nitude Ib/ft F... Start Location[in.%l End Location in X -.331 -.331 0 0 2 M1 Y .191 .191 0 0 3 M2 X -.331 -.331 0 0 4 M2 Y .191 .191 0 0 5 M3 X -.793 -.793 0 0 6 M3 Y .458 .458 0 0 7 M9 X -.793 -.793 0 0 8 M9 Y .458 .458 0 0 9 M10 X -.361 -.361 0 0 10 M10 Y .209 .209 0 0 11 Mil X -.361 -.361 0 0 12 Mil Y .209 .209 0 0 Member Distributed Loads (BLC 14 : Structure Wind w/Ice (45)) 1 Member Label M1 Direction X Start Magnitude[lb/ft,...End -.18 Magnitude[Ib/ft,F... -.18 Start Location[in,%] 0 End Location[in 0 2 M1 Y .18 .18 0 0 3 M2 X -.18 -.18 0 0 4 M2 Y .18 .18 0 0 5 M3 X -.648 -.648 0 0 6 M3 Y .648 .648 0 0 7 M9 X -.648 -.648 0 0 8 M9 Y .648 .648 0 0 9 M10 X -.59 -.59 0 0 10 M10 Y .59 .59 0 0 11 Mil X -.59 -.59 0 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 10 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 11 RISA Job1gner Number : EJE ChecOAM ked By: A NEMETSCHEK COMPANY Model Name SEO1451A Member Distributed Loads (BLC 14 : Structure Wind w/ Ice (45)) (Continued) Member Label Direction Start Ma nitude Ib/ft ... End Ma nitude Ib/ft F... Start Location[in,%1 End Location in 12 Mil y .59 .59 1 0 0 Member Distributed Loads (BLC 15 : Structure Wind w/Ice (60)) Mamhar I ahal nirartinn Start Mannifurlarlh/ft Fnrl Mannifurlarlh/ft F Start 1 nrntinnrin %1 Fnrl 1 nrnfinnrin 0M 1 M1 X -.064 -.064 0 0 2 M1 Y .11 .11 0 0 3 M2 X -.064 -.064 0 0 4 M2 Y .11 .11 0 0 5 M3 X -.458 -.458 0 0 6 M3 Y .793 .793 0 0 7 M9 X -.458 -.458 0 0 8 M9 Y .793 .793 0 0 9 M 10 X -.626 -.626 0 0 10 M 10 Y 1.084 1.084 0 0 11 Mil X -.626 -.626 0 0 12 Mil Y 1.084 1.084 0 0 Member Distributed Loads (BLC 16 : Structure Wind w/Ice (90)) Member Label Direction X Start Ma nitude Ib/ft ... End Ma nitude Ib/ft F... Start Location in % End Location in 1 M1 0 0 0 0 2 M1 Y 0 0 0 0 3 M2 X 0 0 0 0 4 M2 Y 0 0 0 0 5 M3 X 0 0 0 0 6 M3 Y .916 .916 0 0 7 M9 X 0 0 0 0 8 M9 Y .916 .916 0 0 9 M10 X 0 0 0 0 10 M 10 Y 1.669 1.669 0 0 11 M11 X 0 0 0 0 12 Mil Y 1.669 1.669 0 0 Member Distributed Loads (BLC 17 : Structure Wind w/ Ice (120)) KA-k- I kni rliron+inn Ctnrt KA-it v+orlh/f+ r=-4 KA-nit vinrlh/f+ G Ct�r+ I nn�finnrin °%7 Cn�J I nn�4innrin °%1 1 M1 X .064 .064 0 0 2 M1 Y .11 .11 0 0 3 M2 X .064 .064 0 0 4 M2 Y .11 .11 0 0 5 M3 X .458 .458 0 0 6 M3 Y .793 .793 0 0 7 M9 X .458 .458 0 0 8 M9 Y .793 .793 0 0 9 M 10 X .626 .626 0 0 10 M 10 Y 1.084 1.084 0 0 11 Mil X .626 .626 0 0 12 Mil Y 1.084 1.084 0 0 Member Distributed Loads (BLC 18: Structure Wind w/ Ice (135)) RA-hcr I h.1 ni-fine Ctor+ RAnnni+, v+orlh/fh Fnrl RAnnni+, irlorlh/fh G Ctmr+ 1-+innrin 0%1 Fnr1 1-finnrin 0%1 1 M1 X .18 .18 0 0 2 M1 Y .18 .18 0 0 3 M2 X .18 .18 0 0 4 M2 Y .18 .18 0 0 5 M3 X .648 .648 0 0 6 M3 Y .648 .648 0 0 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 11 Company Kimley-Horn and Associates, Inc. Mar 2, 2022 11 RISA Job1gner Number : EJE ChecOAM ked By: A NEMETSCHEK COMPANY Model Name SEO1451A Member Distributed Loads (BLC 18 : Structure Wind w/ Ice (135)) (Continued) AAamhar I Thal ni-tinn Ctort AAnnnifi irlarlh/f+ Gnrl Unnnifi irlarlh/ft G Ctort 1-tinnnn om Gnfl I-tinnrin om 7 M9 X .648 .648 0 0 8 M9 Y .648 .648 0 0 9 M 10 X .59 .59 0 0 10 M 10 Y .59 .59 0 0 11 Mil X .59 .59 0 0 12 M 11 Y .59 .59 0 0 Member Distributed Loads (BLC 19 : Structure Wind w/ Ice (150)) KAamhar I nhal nirartinn Ctorf Manni+i irlaflh/ft Fnrl Manni+i irlaflh/ft F C#art I nra+innrin 0/-1 Fnrl 1 nratinnrin 0/-1 1 M 1 X .331 .331 0 0 2 M1 Y .191 .191 0 0 3 M2 X .331 .331 0 0 4 M2 Y .191 .191 0 0 5 M3 X .793 .793 0 0 6 M3 Y .458 .458 0 0 7 M9 X .793 .793 0 0 8 M9 Y .458 .458 0 0 9 M 10 X .361 .361 0 0 10 M 10 Y .209 .209 0 0 11 Mil X .361 .361 0 0 12 Mil Y .209 .209 0 0 Member Distributed Loads (BLC 36 : Seismic X) Uamhar I ahal nirartinn Ctnrt Unnniti irlaflh/ft Fnrl KAanni+i Aanh/ft F Ctnrr 1 nratinnrin 0/ 1 Fnrl 1 nratinnrin 0/ 1 1 M 1 X 1.585 1.585 0 0 2 M2 X 1.585 1.585 0 0 3 M3 X 1.562 1.562 0 0 4 M9 X 1.562 1.562 0 0 5 M 10 X 3.272 3.272 0 0 6 Mil X 3.272 3.272 0 0 Member Distributed Loads (BLC 37 : Seismic Y) 1 Member Label M 1 Direction Start Ma nitude Ib/ft ... End Ma nitude Ib/ft F... Start Location in % End Location in Y 1.585 1.585 0 0 2 M2 Y 1.585 1.585 0 0 3 M3 Y 1.562 1.562 0 0 4 M9 Y 1.562 1 1.562 0 0 5 M 10 Y 3.272 3.272 0 0 6 Mil Y 3.272 3.272 0 0 Member Area Loads Joint A Joint B Joint C Joint D Direction Distribution Ma nitude s No Data to Print ... Envelope Joint Reactions 1nin+ Y rlhl 1 r v rlhl 1 r 7 nhl 1 r RAY rIf-f+l 1 C NAv rlr-f+l 1 r` RA7 rlr-ftl 1 C 1 N3 max 13.485 64 27.895 63 173.253 25 0 66 0 66 0 66 2 min -115.134 24 -27.895 39 41.182 50 0 1 0 1 0 1 3 N4 max 13.485 54 27.895 63 173.253 29 0 66 0 66 0 66 4 min -115.134 30 -27.895 39 41.182 36 0 1 0 1 0 1 5 N2 max 115.351 22 32.916 63 197.331 22 0 66 0 66 0 66 6 min -19.548 46 -32.916 39 44.906 45 0 1 0 1 0 1 RISA-3D Version 17.0.2 [KA... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 12 11RISCompany A Designer Job Number Model Name Kimley-Horn and Associates, Inc. EJE SE01451A Mar 2, 2022 11:10 AM Checked By: Envelope Joint Reactions (Continued) inint Y nhl i (` v rihl i (` 7 nhl i (` RAY r4_ftl i r` KAV nr_ftl i r` nn7 rlr_ftl i r` 7 N 1 max 115.351 32 32.916 63 197.331 32 0 66 0 66 0 66 8 min-19.548 40 -32.916 39 44.906 41 0 1 0 1 0 1 9 Totals: max 121.621 51 121.621 63 728.915 19 10 min-121.621 43 -121.621 39 284.604 1 Envelope RISC 15th(360-16): LRFD Steel Code Checks Mamhar Shnna (.nrla (.hark I nrfinll ('. Shaar I nrrinlrlirl (. nhi*Pnrr, nhi*Pnt r nhi*Mn nhi*KAn (.h Frin 1 M 10 PL6x3/8 .256 10 29 .008 10 z 31 45512.9.. 70875 .554 8.859 1.. H 1-1 b 2 Mil PL6x3/8 .254 10 33 .008 10 z 31 45512.9.. 70875 .554 8.859 1 - H 1-1 b 3 M3 P2 STD .091 36.8...19 .012 36.8... 19 28419.3.. 33847.7.. 1.997 1.997 1 H1-1b 4 M1 L3X3X3 .084 6 30 .016 0 2928334.9.. 35316 1.32 2.905 1.. H2-1 5 M9 P2 STD .062 36.8...29 .035 42.6... 63 28419.3.. 33847.7.. 1.997 1.997 2.. H1-1b 6 M2 L3X3X3 .060 6 22 .018 12 32 28334.9.. 35316 1.32 2.905 1., H2-1 RISA-3D Version 17.0.2[K:\... \... \... \... \... \... \5-SA Rerun\RISA\SE01451A.r3d] Page 13 T-Mobile Site ID: SE01451A Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION KH Job # KHCLE-7686 Page 7 APPENDIX C Shroud Calculations (By Others, For Reference Only) NB+C Engineering Services Raycap Screen Wall Design Prepared for Raycap Concealment — T-Mobile New Site Build SITE INFORMATION Address T-Mobile Site Name Raycap Project Number NB+C Project Number Date NB+C Engineering Services, LLC Prepared by: Anila Rajbhandari Shakya, P.E. Respectfully Submitted by: Philip Voegtle Jr., P.E. Senior Structural Specialist WA PE License #56812 1001 5th Ave S Edmonds, WA 98020 The Executive TM21-00586H-32R2 100111 February 23, 2022, Rev 2 56812 2/23/2022 NB+C ES, LLC Standard Calculation Sheet 1 6095 Marshalee Drive Subject: Date: 3/9/2022 Suite 300 STEALTH® Screen Design The Executive.xmcd Elkridge, MD 21075 JOB NUMBER: 100111 1. Wind Load on Proposed Screenina PerASCE/SE17-16: ASCE/SEI 7-16 Reference Occupancy Category: II Table 1.5-1 Exposure: Exp:= "C" Section 26.7.3 Topographic Factor: Kzt:= 1.0 Section 26.8 Wind Directional Factor: Kd := 0.85 Table 26.6-1 Ground Elevation Factor: Ke := 1.0 Section 26.9 Gust Effect Factor: G := 0.85 iwv Section 26.11.1 Basic Wind Speed (mph): V:= 98 iwv Figure 26.5-1 A-D Building HeightAGL (ft): h := 40.5 Top HeightAGL (ft): z := 43 Velocity Pressure Exposure zg:= 1200 if Exp = "B" = 900 Table 26.11-1 Coefficient: 900 if Exp = "C" 700 if Exp = "D" a:= 7 if Exp = "B" = 9.5 9.5 if Exp = "C" 11.5 if Exp = "D" 2 max(15 z) Table 26.10-1 Kz:= 2.01. = 1.06 zg J Consider Proposed Screening as Parapet for Reactions on Framing: Velocity Pressure (pst): qp := 0.00256• KZ Kzf Kd• Ke V2psf Equation 26.10.2 qp = 22.1•ps Combined Net Pressure Coefficient: GCpn := 1.0 (Leeward) Section 27.3.4 Design Wind Pressure (psf): pp := qp• GCpn Equation 27.3-3 pp = 22.1•ps Combined Net Pressure Coefficient: Gam:= 1.5 (Windward) Section 27.3.4 Design Wind Pressure (psf): q • GC p pn Equation 27.3-3 pp = 33.2.ps NB+C ES, LLC Standard Calculation Sheet 2 6095 Marshalee Drive Subject: Date: 3/9/2022 Suite 300 STEALTH® Screen Design The Executive.xmcd Elkridge, MD 21075 JOB NUMBER: 100111 Radorne on top of building roof Length of the radome Height of the radome Wind Load = 7ft 1:= loft WL : = pp• L• H = 2325.1 • lbf Seismic Demands check on Non Structural Components SDS:= 1.283 a := 2.5 1.0 Wp := 10001bf Rp := 3 Horizontal Force Table 13.5-1/13.6-1 Section 13.1.3 Assumed from RISA Table 13.5-1/13.6-1 13.3.1.1 Fh := min max 0.4ap• SDS• Wp • C1 + 2• z —1 0.3SD5Ip• W 1.6SD9 Ip W R hJ I J J Fh = 1335.8•lbf Vertical Force 13.3.1.2 Fv:= 0.2• SDS• Wp = 256.6lbf Hence := "Wind loading governs" if Fh < WL "Seismic loading governs" if Fh > WL Hence — "Wind loading governs" Panel Fastner Check Total number of bolts at 12" O.0 7 Number of levels n := 2 For #14 SS screw with 3/8" SS FW (Conservative assumption from stealth handbook) Punch Through Capacity between panel screw and fastner head Tc := 1751bf• N• n = 2.450• kip Total Load on the Panel Tp := 0.6pp• L. H = 1.395• kip Hence = "O.K" NB+C ES, LLC Standard Calculation Sheet 3 6095 Marshalee Drive Subject: Date: 3/9/2022 Suite 300 STEALTH® Screen Design The Executive.xmcd Elkridge, MD 21075 JOB NUMBER: 100111 Columnn Reactions from RISAAnalysis Joint X [k] L.0 Y [k] LC Z [k] N65 mac .331 13 .761 0 .400 min -.849 0 z 0 N15 mac .357 8 .711 8 -18 min -.334 1 0 2? hd50 mac 709 0 .695 _ it } min -.219 14 0 -.185 N 6 8 mac .502 3 0 2 .013 min -.411 1,3 8 0 -.168 P'dl]II may 033 1- I 2 .053 min -.374 8 -.-;87 -.042 I159 1 max j .19v j j '1 j2j 0 min 0 2 2°3' 0 -.021 Beam: M53 Shape: L4X4X6 Material: FRP Length: 3.5 ft I Joint: N44 J Joint: N48 Envelope Cade Check: 0.068 (LC 15) Report Based On 97 Sections 01 at 1.; 1 ft .002 at F , ft Dz Dy in -.011 at Oft -.008 at 1.677 ft .119 at 0 ft .025 at Oft A k Vy k -.022 at 0 ft -.118 at 0 It Check for 1/2" FRP Bolts: Fx:= 251bf Fy:= 1191bf Fz : = 91bf Pb.ult 20001bf Vb.ult 26001bf FS:= 3 N: = 2 Ma)amum Tension force (inY-direction) Ma)amum Shearat each (in X and Z direction) 005at0ft Vz k -.009 at 3.5 ft Ma)amum Design Forces from RISA Ultimate Tensile Capacity of FRP Bolts Ultimate Shear capacity of FRP Bolts Factor of Safety Numberof Bolts FS• Pmax FS• Vmax Inter : _ + = 3.4• % N Pb.ult N. Vb.ult Hence = "O.K" Pmax Fx = 25• lbf Vmax := Fx + Fz Vmax = 26.6• lbf x 1 1 Loads: eLc 1, oEno Envelope oMy WO'. NB+C ES SK-2 ARS The Executive Mar 9, 2022 at 4:34 PM 100111 Rendering The Executive - Copy.r3d Y F tlon etc E abg9e� Z�X Wi g � aF F W °Vb e 2 d ` a pF 2 7 PF Enval OMy W'"'. NB+C ES SK - 7 ARS The Executive Mar 9, 2022 at 4:38 PM 100111 Section Sets The Executive - Copy.r3d x 03-f Loads: BLC 3, W INo Z Envelope oMy Bdudos NB+C ES SK - 4 ARS The Executive Mar 9, 2022 at 4:37 PM 100111 Wind Load The Executive -Copy.r3d x I j.1 Loads: eLc z, WIND x Envelope oNy 9 1—. NB+C ES SK - 5 ARS The Executive Mar 9, 2022 at 4:38 PM 100111 Wind Load The Executive -Copy.r3d oz s� z o, 0 ti DIspla d(EvIl d) elope Only Solution NB+C ES SK - 3 ARS The Executive Mar 9, 2022 at 4:37 PM 100111 Member Stress The Executive - Copy.r3d IIIRISA' A NEMETSCHEK COMPAN`' Company Designer Job Number Model Name NB+C ES ARS 100111 The Executive Checked By: PJV Hot Rolled Steel Properties I �hel C rLcil r] rLcil Ali. Therm //4 Cr. C) rlcnoitvrL/ftA'21 v;niwLcil Dv m.rL-il Dt 1 A36 Gr.36 29000 11154 .3 .65 .49 36 1.5 58 1 1.2 2 A572 Gr.50 29000 11154 .3 .65 .49 50 1.1 65 1.1 3 A992 29000 11154 .3 .65 .49 50 1.1 65 1.1 4 A500 Gr.B R... 29000 11154 .3 .65 .527 42 1.4 58 1.3 5 500 Gr.B Rect 29000 11154 .3 .65 .527 46 1.4 58 1.3 6 A53 Gr.B 29000 11154 .3 .65 .49 35 1.6 60 1.2 7 A1085 29000 11154 .3 .65 .49 50 1.4 65 1.3 8 FRP 2800 450 .35 .44 .12 16.67 1.5 30 1.2 Hot Rolled Steel Section Sets I nhal Chnna Tuna r)acinn 1 ict Matarial r)acinn A rin71 i%A/ rindl 177 rindl .I rindl 1 Post L4X4X6 Column S uareTube A36 Gr.36 T ical 2.86 4.32 4.32 .141 2 in L4X4X6 Beam Single Angle FRP Typical 2.86 4.32 4.32 .141 3 outrigger L4X4X6 HBrace Single Angle A36 Gr.36 T ical 2.86 4.32 4.32 .141 4 Vertical brace L4X4X6 VBrace Single Angle FRP Typical 2.86 4.32 4.32 .141 5 Corner Brace L6X6X6 VBrace Sin le An le FRP T ical 4.38 15.4 15.4 .218 6 steel outrigaer HSS4X4X4 I VBrace I ScivareTube IA500 Gr.B Red T ical 1 3.37 7.8 7.8 1 12.8 Hot Rolled Steel Design Parameters I �KoI Qh- 1 annfhrffl 1 hvvrffl I h,,rftl I r n fnnrffl I n n hntrftl I _fnrni. V- rho r`h Gi.nnfinn 1 M 1 Post 6.5 Lbyy Lateral 2 M2 Post 6.5 Lbyy Lateral 3 M3 outrigger 3 Lbyy Lateral 4 M4 outrigger 3 Lbyy Lateral 5 M5 girt 6.5 Se ment Se ment Lbvv Segme... Lateral 6 M6 girt 2.5 Segment Segment Lbyy Segme... Lateral 7 M7 outriciger 3 Se ment Segment ISegme... Lateral 8 M8 outrigger 3 Segment Segment Lbyy Segme... Lateral 9 M9 Post 5.25 Lateral 10 M 10 Vertical bracel 6.25 1 Lateral 11 M 11 Vertical brace 4.75 Lateral 12 M 12 Vertical brace 3.5 Lateral 13 M 13 Post 3.5 Lateral 14 M 14 Post 4.8 Lateral 15 M 15 outriacler 2 Lbyy Lateral 16 M 16 outrigger 2 Lbyy Lateral 17 M17 girt 7 Se ment Se ment Lbvv I Segme... Lateral 18 M18 girt 3.5 Segment Segment Lbyy Segme... Lateral 19 M 19 Post 4.8 Lateral 20 M20 outrigger 2 Lbyy Lateral 21 M21 outriacler 1 2 Lbvv Lateral 22 M22 Post 4.8 Lateral 23 M23 outrigger 2 Lbvv Lateral 24 M24 outri er 2 Lbyy Lateral 25 M25 Vertical brace 6.3 Lateral 26 M26 Vertical brace 6.3 Lateral 27 M27 Vertical bracel 6.3 Lateral 28 M28 Post 5 Lateral 29 M29 outrigger 2 Lbvy Lateral 30 M30 outrigger 2 Lbyy Lateral 31 M31 girt 7 Segment Segment Lbvv Segme... Lateral 32 M32 in 3.5 Segment Segment Lb Segme... Lateral 33 M33 Post 5 Lateral RISA-3D Version 17.0.4 [RA ... \... \... \... \Structural\REV3\Analysis\The Executive - Copy.r3d] Page 1 IIIRISA' A NEMETSCHEK COMPAN`' Company Designer Job Number Model Name NB+C ES AIRS 100111 The Executive Checked By: PJV Hot Rolled Steel Design Parameters (Continued) I zhn— I o thrftl I hvvrftl I h­rf+l I r n tnnrftl I r n hntrftl I _tnr V V­ ('h Fii +inn 34 M34 outrigger 2 Lbyy Lateral 35 M35 outrigger 2 Lbyy Lateral 36 M36 Post 5 Lateral 37 M37 outrigger 2 Lbyy Lateral 38 M38 outriclaer 2 Lbyy Lateral 39 M39 Yertical brace 6.5 Lateral 40 M40 Yertical brace 6.5 Lateral 41 M41 Vertical brace 6.5 Lateral 42 M42 outrigger 3 Se ment Se ment Lbyy Segme... Lateral 43 M43 outrigger 3 Segment Segment Lbyy Segme... Lateral 44 M44 Post 3.5 Lateral 45 M45 Post 4 Lb Lateral 46 M46 outrigger 3 Lb Lateral 47 M47 outrigger 3 Segment Segment Lbyy Segme... Lateral 48 M48 outri er 3.162 Lateral 49 M49 girt 4.272 Lateral 50 M50 girt 4 Lbyy Lateral 51 M51 girt 4 Segment Segment Lbyy Segme... Lateral 52 M52 girt 3.5 Segment Se ment Lbyy Segme... Lateral 53 M53 girt 3.5 Segment Segment Lbyy Segme... Lateral 54 M54 girt 7 Segment Se ment Lbyy Segme... Lateral 55 M55 girt 7 Segment Segment Lbyy Segme... Lateral 56 M59 Post 1.25 Lateral 57 M57 outrigger 2.25 Lb Lateral 58 M58 outrigger 2.25 Lb Lateral 59 M59A outrigger .75 Lbyy Lateral 60 M60 outrigger .75 Lb Lateral Member Area Loads (BLC 2: WIND X) mint A mint R Inint (' Inin+ n nir--inn nic+rihi rtinn r%Annniti irnn,,cfl 1 N1 N3 N62 N66 X B-C .033 2 N 17 N 18 N69 N 16 X B-C .033 3 N38 N39 N72 N37 X B-C .033 Member Area Loads (BLC 3: WIND Z) _Inint A _Inin} R _Inin} ('. _mint n nircrtinn nietrihi rfinn Manniturlcrkcn 1 N39 N47 N74 N72 Z B-C -.033 2 N18 N26 N71 N69 Z B-C -.033 3 N3 N6 N61 N62 Z B-C -.033 Basic Load Cases RI r: ncerrintinn (:aten—, X (:ra iitxN (:r—itv7 Gravity _Inint Pnint nietrihii Arca(NA RiirFnnn 1 DEAD DL -1 2 2 WIND X WLX 3 3 WIND Z WLZ 3 4 BLC 2 Transient Area Loads None 32 5 BLC 3 Transient Area Loads None 37 RISA-3D Version 17.0.4 [RA ... \... \... \... \Structural\REV3\Analysis\The Executive - Copy.r3d] Page 2 IIIRISA' A NEMETSCHEK COMPAN`' Company Designer Job Number Model Name NB+C ES AIRS 100111 The Executive Checked By: PJV Load Combinations F)o ,intinn Q P QP R G. RI r G. RI C Girt RI r G.r4 R P. R G. R G. R Gm R Gn R Gn mIBC 16-13 ��-m�®�m®®®■-■-■-■-■-■- ® IBC 16-13 ��-m�®�m®®®■-■-■-■-■-■- Envelope Joint Reactions _Inint X fkl I r v rkl I r 7 fkl I (: KAY fk-ftl I (: KAv rlr-ftl I r KA7 fk-ftl I rt 1 N 12 max .036 14 .13 6 .014 16 0 17 0 17 0 17 2 min -.05 8 -.049 16 -.033 6 0 1 0 1 0 1 3 N 15 max .357 8 .711 8 .08 15 0 17 0 17 0 17 4 min -.334 14 0 2 -.29 9 0 1 0 1 0 1 5 N28 max .045 16 .016 13 .075 17 0 17 0 17 0 17 6 imin -.046 1 6 0 2 1 -.078 7 0 1 0 1 0 1 7 N29 max .001 15 .016 13 .16 17 0 17 0 17 0 17 8 min -.001 9 0 2 -.161 7 0 1 0 1 0 1 9 N30 max .035 7 .016 13 .074 17 0 17 0 17 0 17 10 min -.035 17 0 2 -.077 7 0 1 0 1 0 1 11 N31 max .074 8 .073 7 .082 1 15 0 17 0 17 0 17 12 min -.071 14 0 2 -.126 9 0 1 0 1 0 1 13 N32 max .002 15 .105 7 .217 15 0 171 0 1 17 0 17 14 min -.002 9 -.023 17 -.272 9 0 1 0 1 0 1 15 N33 max .039 17 .074 7 .07 15 0 17 0 17 0 17 16 min -.04 7 0 2 -.116 9 0 1 0 1 0 1 17 N34 max .103 16 .075 9 .219 7 0 17 0 17 0 17 18 min -.103 6 0 2 -.17 17 0 1 0 1 0 1 19 N35 max .003 15 .116 9 .415 7 0 171 0 1 17 0 17 20 min -.003 9 -.025 15 -.362 17 0 1 0 1 0 1 21 N36 max .046 17 .075 9 .229 7 0 17 0 17 0 17 22 min -.047 7 0 2 -.178 17 0 1 0 1 0 1 23 N49 max .052 16 .017 13 .072 17 0 17 0 17 1 0 17 24 min -.052 6 0 2 -.075 7 0 1 0 1 0 1 25 N50 max 0 15 .017 13 .155 17 0 17 0 17 0 17 26 min 0 9 0 2 1 -.156 7 1 0 1 0 1 0 1 27 N51 max .034 7 .017 13 .072 17 0 17 0 17 0 17 28 min -.034 17 0 2 -.075 7 0 1 0 1 0 1 29 N52 max .074 8 .074 7 .086 15 0 17 0 17 0 17 30 min -.072 14 0 2 -.128 9 0 1 0 1 0 1 31 N53 max .002 15 .108 7 .225 15 0 17 0 17 0 17 32 min -.002 9 -.025 17 -.278 9 0 1 0 1 0 1 33 N54 max .04 17 .076 7 .074 15 0 17 0 17 0 17 34 min -.041 7 0 2 -.117 9 0 1 0 1 0 1 35 N55 max .104 16 .077 9 .218 7 0 17 0 17 1 0 17 RISA-3D Version 17.0.4 [RA ... \... \... \... \Structural\REV3\Analysis\The Executive - Copy.r3d] Page 3 IIIRISA' A NEMETSCHEK COMPAN`' Company Designer Job Number Model Name NB+C ES AIRS 100111 The Executive Checked By: PJV Envelope Joint Reactions (Continued) mint Y rLl i (` V rLl I r 7 rLl I C RAY rlr_frl I f RAv rL_f i i (` RA7 rlr_f l I C 36 min -.105 6 0 2 -.172 17 0 1 0 1 0 1 37 N56 max .003 15 .118 9 .416 7 0 17 0 17 0 17 38 min -.003 9 -.026 15 -.365 17 0 1 0 1 0 1 39 N57 max .046 17 .077 9 .228 7 0 17 0 17 0 17 40 min -.047 7 0 2 -.18 17 0 1 0 1 0 1 41 N58 max .709 8 .695 6 .04 15 0 17 0 17 0 17 42 min -.219 14 0 2 -.185 9 0 1 0 1 0 1 43 N 13 max .04 6 .143 8 .053 8 0 17 0 17 0 17 44 min -.026 16 -.059 14 -.012 14 0 1 0 1 0 1 45 N59 max .195 6 0 2 0 2 0 17 0 17 0 17 46 min 0 2 -.266 8 -.021 9 0 1 0 1 0 1 47 N60 max .033 14 0 2 .053 6 0 17 0 17 0 17 48 min -.374 8 -.387 6 -.042 16 0 1 0 1 0 1 49 N65 max .331 16 .761 8 .408 7 0 17 0 17 0 17 50 min -.849 6 0 2 0 2 0 1 0 1 0 1 51 N68 max .502 6 0 2 .013 14 0 17 0 17 0 17 52 min -.411 16 -.658 8 -.168 8 0 1 0 1 0 1 53 Totals: max 1.007 16 1.616 13 2.128 15 54 min -1.007 6 0 2 -2.128 9 Envelope A/SC 15th(360-16): ASD Steel Code Checks NAcmh 4ZK.- Cnrlc Chcrlr I nrrf+l 1 C Ch 1 1 C ID- Gn+/ KAn.ni/nm KA-1� f`h Gnn 1 M1 L4X4X6 .077 0 7 .030 3... Z 8 36.3..61.6... Z926 6.578 2.005 1-12-1 2 M2 L4X4X6 .084 3.453 g .033 3... Z 8 36.3.. 1.6.. 2.926 6.383 1.595 1-12-1 3 M3 L4X4X6 .056 3 6 .005 3 y 6 55.0..61.6... 2.926 6.578 1.726 1-12-1 4 M4 L4X4X6 .043 3 8 .007 3 Z 8 55.0...61.6.. 2.926 6.578 1.771 1-12-1 5 M5 L4X4X6 .041 2.505 8 .007 2... Z $ 6.17428.5... 1.355 2.06 2.567 1-12-1 6 M6 L4X4X6 .043 2.5 6 1.006 2.5 vi 6 P.092 28.5.. .979 2.06 3.113 1-12-1 7 M7 L4X4X6 .018 0 8 .003 0 y 8 55.0...61.6... 2.926 6.578 1.916 1-12-1 8 M8 L4X4X6 .017 0 8 .003 Q Z 8 55.0.. 1.6.. 2.926 6.578 2.753 1-12-1 9 M9 L4X4X6 .051 3.5 8 .019 4... 6 43.6...61.6... 2.926 6.578 2.411 1-12-1 10 M 10 L4X4X6 .035 4.688 6 .006 3... 6 4.478 28.5.. .979 2.06 2.862 H2-1 11 M 11 L4X4X6 .024 3.513 8 .003 3... 8 6.34 28.5... 1.355 2.104 1.544 H2-1 12 M 12 L4X4X6 .001 3.5 14 .000 Q g .868 28.5.. 1.355 1.984 1 H2-1 13 M 13 L4X4X6 .021 0 8 .002 Q Z 6 52.9...61.6... 2.926 6.578 2.216 1-12-1 14 M 14 L4X4X6 .046 .75 7 .008.75 y 7 46.2...61.6.. 2.926 6.578 2.039 1-12-1 15 M 15 L4X4X6 .024 2 9 .004 Z_y g 58.6...61.6... 2.926 6.578 2.137 1-12-1 16 M 16 L4X4X6 .035 2 7 .004 2 Z 7 58.6...61.6.. 2.926 6.578 2.249 1-12-1 17 M 17 L4X4X6 .057 3.5 7 .011 3.5 Z 7 5.86828.5... 1.355 2.06 11.426 1-12-1 18 M 18 L4X4X6 .061 3.5 15 .012 Q vi 7 5.868 28.5.. .979 2.06 1.521 1-12-1 19 M 19 L4X4X6 .071 .75 7 .015 Q Z 7 46.2...61.6... 2.926 6.578 2.251 1-12-1 20 M20 L4X4X6 .041 2 9 .007 2 Z g 58.6...61.6.. 2.926 6.578 2.281 1-12-1 21 M21 L4X4X6 .059 2 7 .006 2 y 7 58.6...61.6... 2.926 6.578 1.685 1-12-1 22 M22 L4X4X6 .049 .75 7 .0081 Q Z 7 46.2...61.6.. 2.926 6.578 2.009 1-12-1 23 M23 L4X4X6 .024 2 9 .003 2 Z g 58.6...61.6... 2.926 6.578 12.126 1-12-1 24 M24 L4X4X6 .036 2 7 .004 7 58.6...61.6.. 2.926 6.578 2.246 1-12-1 25 M25 L4X4X6 .031 4.856 7 .004 -Ly 4... Z 7 4.407128.5... 1.355 2.06 2.178 1-12-1 26 M26 I L4X4X6 .066 4.856 g .006 4... ZI g 4.40728.5.. 1.355 2.06 3.691 1-12-1 27 M27 L4X4X6 .033 4.856 7 .004 4... 7 4.407 28.5... .979 2.06 2.035 1-12-1 28 M28 L4X4X6 .046 .729 7 .008 Q y 7 45.1.. 1.6.. 2.926 6.578 2.03 1-12-1 29 M29 L4X4X6 .025 2 9 .004 g 58.6..61.6... 2.926 6.578 2.141 1-12-1 30 M30 L4X4X6 .035 2 7 .004 -Ly 2 Z 7 58.6..61.6.. 2.926 6.578 2.249 1-12-1 31 M31 L4X4X6 .059 3.5 7 .012 3.5 Z 7 .868 28.5... 1.355 2.06 1.422 1-12-1 32 M32 L4X4X6 .063 3.5 15 .012 Q yj 7 5.868 28.5.. .979 2.06 11.525 H2-1 33 M33 L4X4X6 .071 .781 7 .015 Q Z 7 45.1..61.6... 2.926 6.578 1 2.238 1-12-1 RISA-31D Version 17.0.4 [RA ... \... \... \... \Structural\REV3\Analysis\The Executive - Copy.r3d] Page 4 Company NB+C ES Designer IIRISA AIRS Job Number 100111 ANEMETSCHEKCOMPAN`Model Name The Executive Envelope RISC 15th(360-16): ASD Steel Code Checks (Continued) Checked By: PJV Memb... Shane Code Check Locrftl LC Sh... L... ... LC Pnc... Pnt/... Mnvv/om ...Mnzz/o... Cb Ean 34 M34 L4X4X6 .042 2 9 .007 2 z 9 58.6...61.6... 2.926 6.578 2.274 H2-1 35 M35 L4X4X6 .061 2 7 .006 2 7 58.6...61.6... 2.926 6.578 1.684 1-12-1 36 M36 L4X4X6 .049 .729 7 .008 0 z 7 45.1.. 1.6.. 2.926 6.578 2.002 H2-1 37 M37 L4X4X6 .024 2 9 .003 2 z 9 58.6..61.6... 2.926 6.578 2.13 1-12-1 38 M38 L4X4X6 .037 2 7 .004 2 y 7 58.6.. 1.6.. 2.926 6.578 2.246 H2-1 39 M39 L4X4X6 .032 5.01 7 .004 5... ZI 7 4.14 28.5... 1.355 2.06 2.24 1-12-1 40 M40 L4X4X6 .068 5.01 9 .006 5... z 9 4.14 28.5.. 1.355 2.06 3.765 H2-1 41 M41 L4X4X6 .035 5.01 7 .004 5... 7 4.14 28.5... .979 2.06 2.109 1-12-1 42 M42 L4X4X6 .032 0 6 .003 0 z 8 55.0.. 1.6.. 2.926 6.578 2.114 H2-1 43 M43 L4X4X6 .034 0 9 .004 0 z 6 55.0..61.6... 2.926 6.578 1.738 1-12-1 44 M44 L4X4X6 .065 0 8 .020 0 z 8 52.9..61.6.. 2.926 6.578 4.743 H2-1 45 M45 L4X4X6 .097 3.5 6 .041 3.5 vi 6 50.4..61.6... 2.926 6.578 1.417 1-12-1 46 M46 L4X4X6 .045 3 6 .011 3 y 6 55.0.. 1.6.. 2.926 6.578 1.618 H2-1 47 M47 L4X4X6 .030 0 6 .003 0 z 6 55.0..61.6... 2.926 6.578 1.341 1-12-1 48 M48 L4X4X6 .014 3.162 6 .005 3... z 6 54.4.. 1.6.. 2.926 6.578 2.331 H2-1 49 M49 L4X4X6 .017 4.094 6 .002 0 z 8 3.459 28.5... .979 1.943 1.17 1-12-1 50 M50 L4X4X6 .059 2 6 .006 2 y 6 .521 28.5.. 1.355 2.06 1.354 H2-1 51 M51 L4X4X6 .077 0 6 .013 0 vi g .52128.5... .979 2.06 2.434 1-12-1 52 M52 L4X4X6 .066 0 15 .013 0 g i.868 28.5.. .979 2.06 2.384 H2-1 53 M53 L4X4X6 .068 0 15 .013 0 y g 5.868 28.5... .979 2.06 2.386 1-12-1 54 M54 L4X4X6 .242 5.031 17 .003 3.5 y -.868 28.5... .979 .082 1.12 H2-1 55 M55 L4X4X6 .243 5.031 17 .003 3.5 y 9 .868 28.5... .979 .082 1.12 1-12-1 56 M59 L4X4X6 .068 1.25 6 .0321... z 6 60.4.. 1.6.. 2.926 6.578 3.245 H2-1 57 M57 L4X4X6 .030 2.25 8 .004 0 y 8 57.8 ... 61.6.. 2.926 6.578 1.848 1-12-1 58 M58 L4X4X6 .037 2.25 6 .006.1.. z 6 57.8.. 1.6.. 2.926 6.578 1.93 H2-1 59 M59A L4X4X6 .055 .75 8 .006 .75 z 8 61.2 ... 61.6.. 2.926 6.578 1.041 1-12-1 60 M60 I L4X4X6 .066 .75 6 .006.75 6 61.2.. 1.6.. 2.926 16.578 11.011 H2-1 RISA-3D Version 17.0.4 [RA ... \... \... \... \Structural\REV3\Analysis\The Executive - Copy.r3d] Page 5 SCE AMERICAN SOCIETY OF CIVIL ENGINEERS Address: 1001 5th Ave S Edmonds, Washington 98020 ASCE 7 Hazards Report Standard: ASCE/SEI 7-16 Elevation: 134.63 ft (NAVD 88) Risk Category: II Latitude: 47.802899 Soil Class: D - Default (see Longitude:-122.377225 Section 11.4.3) C luh Iroumu PoII1.4atlrmn `I.ju-h Hr:lenetlrmt�on Wind Results: Wind Speed: 98 Vmph 10-year MRI 67 Vmph 25-year MRI 74 Vmph 50-year MRI 78 Vmph 100-year MRI 83 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4, and Section 26.5.2 Date Accessed: Mon Jun 21 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane -prone region as defined in ASCE/SEI 7-16 Section 26.2. https://asce7hazardtool.online/ Page 1 of 3 Mon Jun 21 2021 -ASCE® AMERICAN SOCIETY OF CIVIL ENGINEERS Seismic Site Soil Class: D - Default (see Section 11.4.3) Results: Ss : 1.283 So, : N/A S, 0.451 TL 6 Fa 1.2 PGA: 0.545 FV N/A PGA m : 0.654 Sans : 1.539 FPGA 1.2 SM, N/A le 1 SIDS : 1.026 Cv 1.357 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Mon Jun 21 2021 Date Source: USGS Seismic Design Maps https://asce7hazardtool.onIine/ Page 2 of 3 Mon Jun 21 2021 -ASCE® AMERICAN SOCIUY OF CIVIL ENGINEERS Ice Results: Ice Thickness: Concurrent Temperature Gust Speed: Data Source: Date Accessed: 1.00 in. 25 F 30 mph Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Mon Jun 21 2021 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third -party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 3 of 3 Mon Jun 21 2021 T-Mobile Site ID: SE01451A Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION KH Job # KHCLE-7686 Page 8 APPENDIX D Connection Calculations Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 1 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: 3/2/2022 Fastening point: Specifiers comments' Mount Bracket Connection 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 316 1/2 (2) hnom1 Item number: 2210264 KB-TZ2 1/2x3 3/4 SS316 Effective embedment depth: hef,act = 2.000 in., hnom = 2.500 in. � � �� Material: AISI 316 Evaluation Service Report: ESR-4266 Issued I Valid: 7/1/2021 1 12/1/2021 SAFE -ET Proof: Design Method ACI 318-19 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.187 in. Anchor platecBFEM . Ix x ly x t = 15.000 in. x 3.000 in. x 0.187 in.; Profile: Rectangular plates and bars (AISC), ; (L x W x T) = 15.000 in. x 0.188 in. Base material: cracked concrete, 2500, f = 2,500 psi; h = 6.000 in. Installation: automatic cleaned drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar cBFEM - The anchor calculation is based on a component -based Finite Element Method (CBFEM) Geometry [in.] & Loading [lb, in.Ib] Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 0 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 2 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: 3/2/2022 Fastening point: 1.1 Design results Case Description Forces [lb] / Moments [in.lb] Seismic Max. Util. Anchor [%] 1 Combination 1 N = 230; Vx = 66; Vy = 396; Mx = 0; My = 0; Mz = 0; 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 469 206 15 206 2 466 197 51 190 resulting tension force in (x/y)=(0.016/0.000): 934 [lb] resulting compression force in (x/y)=(0.027/0.255): 854 [lb] Anchor forces are calculated based on a component -based Finite Element Method (CBFEM) 3 Tension load Load Nua [lb] Steel Strength" 469 Pullout Strength* N/A Concrete Breakout Failure— 934 highest loaded anchor "anchor group (anchors in tension) no 31 02 c 01 Tension Capacity � N° [lb] Utilization PN = Nua/f N° Status 8,906 6 OK N/A N/A N/A 3,108 31 OK Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: 3/2/2022 Fastening point: 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 � Nsa >> Nua ACI 318-19 Table 17.5.2 Variables 1 1 Ase,N [in.) fwa [psi] 0.10 120,404 Calculations Nsa [lb] 11.875 Results Nsa [lb] steel Nsa [lb] Nua [lb] 11,875 0.750 8,906 469 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Address: Phone I Fax: Design: Concrete - Mar 2, 2022 (1) Fastening point: Page: Specifier: E-Mail: Date: 3.2 Concrete Breakout Failure Ncbg = QNC ) W ec,N Wed,N Wc,N Wcp,N Nb NcO ACI 318-19 Eq. (17.6.2.1b) Ncbg > Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANco = 9 hef ACI 318-19 Eq. (17.6.2.1.4) 1 W ec,N = 2 eN < 1.0 ACI 318-19 Eq. (17.6.2.3.1) 1 +— \ 3 hef / W ed,N = 0.7 + 0.3 (CLM ) < 1.0 1.5hef ACI 318-19 Eq. (17.6.2.4.1b) W cp,N = MAX(c=min 1.5hef) < 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Cac �C�ac 1. Nb = kc �`' a Vfc hef5 ACI 318-19 Eq. (17.6.2.2.1) Variables hef, [in.] ec1,N [in.] ec2,N [in.] ca,min [in.] W c,N 2.000 0.016 0.000 1.000 Cac [In.] kC ), a fc [psi] 6.000 17 1.000 2,500 Calculations ANc [in.2] ANcp [in•21 W ecl,N Wec2,N Wed,N Wcp,N Nb [lb] 72.00 36.00 0.995 1.000 1.000 1.000 2,404 Results Ncba [lb] 0 concrete Ncba [lb] Nua [lb] 4,782 0.650 3,108 934 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 3/2/2022 4 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 5 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: 3/2/2022 Fastening point: 4 Shear load Load Vua [lb] Steel Strength* 206 Steel failure (with lever arm)* N/A Pryout Strength* 206 Concrete edge failure in direction ** N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC-ES ESR-4266 � Vsteel > Vua ACI 318-19 Table 17.5.2 Variables Ase,v [in.2] fa [psi] 0.10 120,404 Calculations Vsa [Ib] 8,348 Results Vsa [Ib] steel Vsa [lb] Vua [Ib] 8,348 0.650 5,426 206 Capacity + Vn [lb] Utilization Ov = Vua/� Vn Status Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5,426 4 OK N/A N/A N/A 1,683 13 OK N/A N/A N/A 5 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: Fastening point: 4.2 Pryout Strength ANc Vcp = kcp [(ANco) W ed,N Wc,N Wcp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) Vcp > Vua ACI 318-19 Table 17.5.2 ANC see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANco = 9 hef ACI 318-19 Eq. (17.6.2.1.4) 1 W ec,N = 1 +2 eN < 1.0 — ACI 318-19 Eq. (17.6.2.3.1) 3 hef / W ed,N = 0.7 + 0.3 (Gamin) < 1.0 1.5hef ACI 318-19 Eq. (17.6.2.4.1 b) W ep N = MAX(Ca=min 1.5hef) < 1.0 ACI 318-19 Eq. (17.6.2.6.1 b) Cac �Caac No = kc a' a Vfc hef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.] ec1,N [in.] eczN [in.] C [in.] a,min 1 2.000 0.000 0.000 W c,N Cac [In.] kc 1.000 6.000 17 Calculations AN, [in .2] 36.00 Results Vcp [ib] 2,404 ,Ncl1 [in •z ] W ecl,N 36.00 1.000 concrete Vcp [Ibl 0.700 1,683 a a fc [psi] 1.000 2,500 W ec2,N Wed,N Wcp,N Nb [lb] 1.000 1.000 1.000 2,404 Vua [ib] %III: 5 Combined tension and shear loads, per ACI 318-19 section 17.8 RN l3V Utilization RN,V [%] Status �y 0.301 0.123 5/3 17 OK NNV = RN + RV <— 1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 3/2/2022 6 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 7 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: 3/2/2022 Fastening point: 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This means load re -distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ • Hilti post -installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. • The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re -distribution to the anchors due to elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment." Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan q C Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 8 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: 3/2/2022 Fastening point: 7 Installation data Profile: Rectangular plates and bars (AISC), ; (L x W x T) = 15.000 in. x 0.188 in. Hole diameter in the fixture: df = 0.562 in. Plate thickness (input): 0.187 in. Drilling method: SafeSet - automatic cleaning Cleaning: Automatically performed while drilling Anchor type and diameter: Kwik Bolt TZ2 - SS 316 1/2 (2) hnom1 Item number: 2210264 KB-TZ2 1/2x3 3/4 SS316 Maximum installation torque: 481 in.lb Hole diameter in the base material: 0.500 in. Hole depth in the base material: 2.750 in. Minimum thickness of the base material: 4.000 in. Hilti KB-TZ2 stud anchor with 2.5 in embedment, 1/2 (2) hnom1, Stainless steel, installation per ESR-4266 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer No accessory required Torque controlled cordless impact tool • Properly sized drill bit for SAFEset - Torque wrench automatic cleaning (TE-CD / TE-YD) Hammer • Vacuum cleaner 7 Gnn 0�0 Y r"�.W O u) O U� O u) O U� 1.500 12.000 1.500 Coordinates Anchor [in.] Anchor x y c-x c+x c-y c,y 1 6.000 -0.000 - 2 -6.000 -0.000 - Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Hilti PROFIS Engineering 3.0.75 www.hilti.com Company: Page: 9 Address: Specifier: Phone I Fax: E-Mail: Design: Concrete - Mar 2, 2022 (1) Date: 3/2/2022 Fastening point: 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3.3.5 KWIK BOLT TZ EXPANSION ANCHOR PRODUCT DESCRIPTION SHROUD CONNECTION KWIK Bolt TZ carbon steel and stainless steel anchors Anchor System Features and Benefit • Used with Hilti Dust Removal System (DRS) for dustless = drilling and installation (compliant with Table 1 of OSHA 1926.1153 regulations for silica dust exposure). • Accurate SafeSetTM installation when using the Hilti SIW- 6AT-A22 impact wrench and the SI-AT-A22 Adaptive Torque 3 Module • Product and length identification marks facilitate quality control after installation. • Through fixture installation and variable thread lengths improve productivity and accommodate various base plate thicknesses. • Type 316 stainless steel wedges provide superior Carbon Steel KB-TZ Stainless Steel KB-TZ I performance in cracked concrete. .y Hilti SIW-6AT-A22 impact wrench and the SI-AT-A22 Adaptive Torque Module • Ridges on expansion wedges provide increased reliability. • Mechanical expansion allows immediate load application. • Raised impact section (dog point) prevents thread damage during installation. • Bolt meets ductility requirements of ACI 318-14 Section 2.3. • ACI 349-01 Nuclear Design Guide is available. Call Hilti Technical Support. Gt FVVI SAFE Uncracked Cracked Grout -filled Seismic Design Hollow Drill Bit concrete concrete concrete Categories A-F with Adaptive masonry Torque Tool (AT) lam 000 000 0 0 0 0 0 0 o 0 0 Profis Anchor Fire sprinkler design software listings Approvals/Listings ICC-ES (International Code Council) ESR-1917 in concrete per ACI 318-14 Ch. 17 /ACI 355.2/ ICC-ES AC193 - 2018 International Building Code / International ESR-3785 in grout -filled CMU per ICC-ES AC01 Residential Code (IBC/IRC) ELC-1917 in concrete perCSAA23.3-14/ACI 355.2 - 2015 National Building Code of Canada (NBC-C) City of Los Angeles 2017 LABC Supplement (within ESR-1917) RR 26057 grout -filled CMU Florida Building Code 2010 FBC with HVHZ FM (Factory Mutual) Pipe hanger components for automatic sprinkler systems 3/8 through 3/4 UL and cUL (Underwriters Laboratory) Pipe hanger equipment for fire protection services for 3/8 through 3/4 A► -=- FM a u� us WMMWWMW=MNc APPROVED LISTED 286 Anchor Fastening Technical Guide Edition 19 13.0 ANCHORING SYSTEMS 1 3.3.5 KWIK BOLT TZ EXPANSION ANCHOR Hilti, Inc. (U.S.) 1-800-879-8000 1 en espanol 1-800-879-5000 1 www.hilti.com I Hilti (Canada) Corporation I www.hilti.com 1 1-800-363-4458 Anchor Fastening Technical Guide, Edition 19 MATERIAL SPECIFICATIONS SHROUD CONNECTION Carbon steel with electroplated zinc Carbon steel KB-TZ anchors have the following minimum bolt fracture loads.' Anchor diameter (in.) Shear (Ib) Tension (lb) 3/8 NA 6,744 1 /2 7,419 11,240 5/8 11,465 17,535 3/4 1 17,535 1 25,853 Carbon steel anchor components plated in accordance with ASTM B633 to a minimum thickness of 5 pm. Nuts conform to the requirements of ASTM A563, Grade A, Hex. Washers meet the requirements of ASTM F844. Expansion sleeves (wedges) are manufactured from type 316 stainless steel Stainless steel Stainless steel KB-TZ anchors are made of type 304 or 316 material and have the following minimum bolt fracture loads.' Anchor diameter (in.) Shear (I b) Tension (lb) _ 3/8 5,058 6,519 8,543 12,364 5/8 13,938 19,109 3/4 1 22,481 1 24,729 All nuts and washers for type 304 anchors are made from type 304 stainless. All nuts and washers for type 316 anchors are made from type 316 stainless. Nuts meet the dimensional reauirements of ASTM F594. Washers meet the dimensional requirements of ANSI B18.22.1, Type A, plain. Expansion sleeve (wedges) are made from type 316 stainless steel. 1 Bolt fracture loads are determined by testing in a universal tensile machine for quality control at the manufacturing facility. These loads are not intended for design purposes. See tables 4 and 16 for the steel design strengths of carbon steel and stainless steel, respectively. INSTALLATION PARAMETERS Figure 1 - Hilti KWIK Bolt TZ specifications r thread fanch Anchor Fastening Technical Guide Edition 19 13.0 ANCHORING SYSTEMS 1 3.3.5 KWIK BOLT TZ EXPANSION ANCHOR 287 Hilti, Inc. (U.S.) 1-800-879-8000 1 en espanol 1-800-879-5000 1 www.hilti.com I Hilti (Canada) Corporation I www.hilti.com 1 1-800-363-4458 SHROUD CONNECTION I Anchor Fastening Technical Guide, Edition 19 Table 15 - Hilti KWIK Bolt TZ stainless steel design strength with concrete / pullout failure in uncracked concrete'AIA5 Nominal Tension - (pNn Shear - On anchor Effective Nominal diameter embed. embed. f'� = 2,500 psi f'� = 3,000 psi f'c = 4,000 psi f. = 6,000 psi f'. = 2,500 psi f'c = 3,000 psi f. = 4,000 psi f. = 6,000 psi in. in. (mm) in. (mm) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) 2 2-5/16 1,710 1,875 2,160 2,650 2,375 2,605 3,005 3,680 3/8 (51) (59) (7.6) (8.3) (9.6) (11.8) (10.6) (11.6) (13.4) (16.4) 2 2-3/8 1,865 2,045 2,360 2,890 2,375 2,605 3,005 3,680 (51) (60) (8.3) (9.1) (10.5) (12.9) (10.6) (11.6) (13.4) (16.4) 1/2 3-1/4 3-5/8 3,745 4,100 4,735 5,800 9,845 10,785 12,450 15,250 (83) (91) (16.7) (18.2) (21.1) (25.8) (43.8) (48.0) (55.4) (67.8) 3-1/8 3-9/16 4,310 4,720 5,450 6,675 9,280 10,165 11,740 14,380 (79) (91) (19.2) (21.0) (24.2) (29.7) (41.3) (45.2) (52.2) (64.0) 5/8 4 4-7/16 6,240 6,835 7,895 9,665 13,440 14,725 17,000 20,820 (102) (113) (27.8) (30.4) (35.1) (43.0) (59.8) (65.5) (75.6) (92.6) 3-3/4 4-5/16 5,665 6,205 7,165 8,775 12,200 13,365 15,430 18,900 (95) (110) (25.2) (27.6) (31.9) (39.0) (54.3) (59.5) (68.6) (84.1) 3/4 4-3/4 5-9/16 7,825 8,575 9,900 12,125 17,390 19,050 22,000 26,945 (121) (142) (34.8) (38.1) (44.0) (53.9) (77.4) (84.7) (97.9) (119.9) Table 16 - Hilti KWIK Bolt TZ stainless steel design strength with concrete / pullout failure in cracked concrete' 2,3,4,5 Nominal Tension - (pNn Shear - On anchor Effective Nominal diameter embed. embed. f'c = 2,500 psi f'. = 3,000 psi f'c = 4,000 psi f. = 6,000 psi f'c = 2,500 psi f'c = 3,000 psi f'c = 4,000 psi f'c = 6,000 psi in. in. (mm) in. (mm) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) Ib (kN) 2 2-5/16 1,520 1,665 1,925 2,355 1,685 1,845 2,130 2,605 3/8 (51) (59) (6.8) (7.4) (8.6) (10.5) (7.5) (8.2) (9.5) (11.6) 2 2-3/8 1,750 1,915 2,210 2,710 2,375 2,605 3,005 3,680 (51) (60) (7.8) (8.5) (9.8) (12.1) (10.6) (11.6) (13.4) (16.4) 1 /2 3-1/4 3-5/8 3,235 3,545 4,095 5,015 6,970 7,640 8,820 10,800 (83) (91) (14.4) (15.8) (18.2) (22.3) (31.0) (34.0) (39.2) (48.0) 3-1/8 3-9/16 3,050 3,345 3,860 4,730 6,575 7,200 8,315 10,185 (79) (91) (13.6) (14.9) (17.2) (21.0) (29.2) (32.0) (37.0) (45.3) 5/8 4 4-7/16 3,795 4,160 4,800 5,880 9,520 10,430 12,040 14,750 (102) (113) (16.9) (18.5) (21.4) (26.2) (42.3) (46.4) (53.6) (65.6) 3-3/4 4-5/16 5,270 5,775 6,670 8,165 12,200 13,365 15,430 18,900 (95) (110) (23.4) (25.7) (29.7) (36.3) Reactions from NB+C Engineering 3/4 4-3/4 5-9/16 5,720 6,265 7,235 8,860 Shroud Design: (121) (142) (25.4) (27.9) (32.2) (39.4) N,, = 400 Ibs < 2,375 Ib OK 1 See section 3.1.8 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive stref V,, = 500 Ibs < 1,750 Ib OK 3 Apply spacing, edge distance, and concrete thickness factors in tables 19 to 26 The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete mult Interaction Check: for sand -lightweight, Aa = 0.68; for all -lightweight, Aa = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncra concrete tabular values in tension by the following reduction factors: Vu/(I)Vn + Pu/(I)Pn 1/2-in diameter by 2-in effective embedment depth - aN,S8m = 0.64 400/1,750 + 500/2,375 = 0.44 < 1.0 OK All other sizes - a,_,e = 0.75 No reduction needed for seismic shear. See Section 3.1.8 for additional informal Anchor Fastening Technical Guide Edition 19 13.0 ANCHORING SYSTEMS 1 3.3.5 KWIK BOLT TZ EXPANSION ANCHOR 295 Hilti, Inc. (U.S.) 1-800-879-8000 1 en espanol 1-800-879-5000 1 www.hilti.com I Hilti (Canada) Corporation I www.hilti.com 1 1-800-363-4458 T-Mobile Site ID: SE01451A Site Name: THE EXECUTIVE HOMEOWNERS ASSOCIATION KH Job # KHCLE-7686 Page 9 APPENDIX E RF Data Sheet/Proposed Scoping Document SE01451A Sprint Retain1draft_2021-02-22 2/22/2021 RAN Template: A8L Template: 56790EZ SR R 56790EZ SR R SE01451A Sprint Retain_1_draft Print Name: Standard PORs: New Build_Sprint Keep Section 1 - Site Information Site ID: SE01451A Site Name: SE01451A Latitude: 47.80273000 Status: Draft Site Class: <undefined> Longitude: -122.37738000 Version: 1 Site Type: <undefined> Address: 1001 5th Ave S Project Type: Sprint Retain Plan Year: City, State: Edmonds, WA Approved: Not Approved Market: SEATTLE WA Region: WEST Approved By: Not Approved Vendor: Nokia Last Modified: 2/21/2021 11:41:38 PM Landlord: Not Specified Last Modified By: Victor.Bayouk@T-Mobile.com w RAN Template: 56790EZ_SIR _R J A#kj AL Template: 56790EZ_SIR _R Sector Count: 3 Antenna Count: 6 4S��&.nj 0 TMA Count: 0 RRU Count: 6 w lab Section 2 - xist g to ges ----- This section is intention ^a-- -- https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/58774968-99f4-4dd6-a7c5-a46142fl l ff0?Iayoutld=2e5l l 2cd-53b 1-4cO5-87... 1 /8 2/22/2021 SE01451A Sprint Retain1draft_2021-02-22 Section 3 - Proposed Template Images 56790EZ_SR_R.jpg Configuration O6USR_R For 5G and LTE Airscale BB dime io to Fiber Port matrices. (Alpha, Beta & A LTE+5G B41 .cFive AnTenn� jiberJumpers Tip �iberJumpers Ground HCS2.0 HCS2.0 Rooftop Rooftop B12 (L700) — 5 MHz B71 (L600) —10 MHz B71 (N600) — 15 MHz FDD - Midband 134/1366 (L2100) — 20 MHz B66 (N2100) — 20 MHz 132 (1-1900) — 20 MHz B25 (L1900) — 20 MHz B25 (N1900) — 20 MHz SRAN — GSM PCS TDD - Band 41 L2.5(2.5GHz)— 60 MHz N41(2.5GHz) — 100MHz +2nd carrier (<=80MHz) SRAM LTE + GSM FSMF 5G Airscale GSM PCS I LTE FDD/TDD Airscalel I https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/58774968-99f4-4dd6-a7c5-a46142f11 ff0?1ayout1d=2e5112cd-53b 1-4c05-87... 2/8 2/22/2021 SE01451A Sprint Retain1draft_2021-02-22 Section 4 - Siteplan Images ----- This section is intentionally blank. ----- https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/58774968-99f4-4dd6-a7c5-a46142f11 ff0?layoutld=2e5112cd-53b 1-4c05-87... 3/8 2/22/2021 SE01451A_Sprint Retain_1_draft_2021-02-22 SE01451A_Sprint Retain_1_draft RAN Template: A&L Template: 56790EZ SR R I 56790EZ SR R n 5 - RAN Equipment Exis Equipment �ti int tionally blank. ----- Print Name: Standard PORs: New Build Sprint Keep Proposed !tW&Iffnen Template: 56790EZ Enclosure 1 2 4 Enclosure Type Tower Top Mount (Nokia) Ancillary Eq ment (Nokia) Generic 600A Site Support Cabinet Generic Battery Cabinet for 600A SSC Baseband ASIB L700 L600 L2100 L1900 ��ASIK N600 N2100 N1900 MFSMFLAWS3L2500 ASIB Baseband Submodule ABIA (x 2 L2100 L1900 LAWS3 ) ABIA ABIL (x 3 ) L700 N2500 L6 00 ABIL N6IL o ABIL (x 2 ) N2100 N1900 ABIC (x 3) L2500 Baseband Subrack AMIA (x 2 ) Junction Box Nokia HCS 2.0 Roof -Top Junction Box (x 2 ) Power subsystem Rectifier Shelf *Select size* Breakers *Select size* Batteries *Select size* Radio AHFIG (x 3) L2100 FE L1900 G1900 LAWS3 N2100 N1900 Transport System CSR IXRe V2 (Gen2) RAN Scope of Work: https:Hrfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheetIPrintout/58774968-99f4-4dd6-a7c5-a46142fl l ff0?Iayoutld=2e5l l 2cd-53b 1-4cO5-87... 4/8 2/22/2021 RAN Template: A8L Template: 56790EZ SR R 56790EZ SR R SE01451A Sprint Retain1draft_2021-02-22 SE01451A Sprint Retain_1_draft n 6 - A&L Equipment ng emplate: Custom IN56790EZ_SIR _R Print Name: Standard PORs: New Build_Sprint Keep Sector 1 (Proposed) view m f : the ' ages show view from behind) Coverage Type A -Outdoor Macro Antenna 1 2 Antenna Model Commscope - FFVV-65C-R3-VI (Octo) AEHC (Active enna -Massive MIMO) Azimuth 20 20 M. Tilt O O Height 43 43 Ports P1 P2 P3 P4 P5 Active Tech. L700 L600 900 L700 L600 N600 9100 L1900 G1900 LAWS3 N2100 N1900 9100 L1900 G1900 LAWS3 N2100 N1900 L2500 N2500 Dark Tech. Restricted Tech. Decomm. Tech. I I E. Tilt Cables I I TMAs Diplexers I Combiners I I Radio I I Sector Equipment I I Unconnected Equipment: Scope of Work: https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/58774968-99f4-4dd6-a7c5-a46142fl l ff0?Iayoutld=2e5l l 2cd-53b 1-4cO5-87... 5/8 2/22/2021 RAN Template: A8L Template: 56790EZ SR R 56790EZ SR R SE01451A Sprint Retain1draft_2021-02-22 SE01451A Sprint Retain_1_draft Print Name: Standard PORs: New Build_Sprint Keep Sector 2 (Proposed) view from front (Note: the images show view from behind) Coverage Type A -Outdoor Macro Antenna 2 Antenna Model Commscope - FFVV-65C-R3-V1 (Octo) AEHC (Active Antenna - Massive MIMO) Azimuth 140 140 M. Tilt O O Height 43 43 Ports P1 P2 P3 P4 P5 Active Tech. L700 L600 900 20 L600 N600 L2 L1900 G1 LAWS3 N2100 N1900 L2100 L1900 G1900 LAWS3 N2100 N1900 L2500 N2500 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt I I Cables I I I I TMAs I I Diplexers I Combiners I I I I Radio I I Sector Equipment I I I I Unconnected Equipment: Scope of Work: https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/58774968-99f4-4dd6-a7c5-a46142f11 ff0?layoutld=2e5112cd-53b 1-4c05-87... 6/8 2/22/2021 RAN Template: A8L Template: 56790EZ SR R 56790EZ SR R SE01451A Sprint Retain1draft_2021-02-22 SE01451A Sprint Retain_1_draft Print Name: Standard PORs: New Build_Sprint Keep Sector 3 (Proposed) view from front (Note: the images show view from behind) Coverage Type A -Outdoor Macro Antenna 2 Antenna Model Commscope - FFVV-65C-R3-V1 (Octo) AEHC (Active Antenna - Massive MIMO) Azimuth 250 250 M. Tilt O O Height 43 43 Ports P1 P2 P3 P4 P5 Active Tech. L700 L600 900 20 L600 N600 L2100 L1900 G1900 LAWS3 N2100 N1900 L2100 L1900 G1900 LAWS3 N2100 N1900 L2500 N2500 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt I I Cables I I I I TMAs I I Diplexers I Combiners I I I I Radio I I Sector Equipment I I I I Unconnected Equipment: Scope of Work: https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/58774968-99f4-4dd6-a7c5-a46142f11 ff0?layoutld=2e5112cd-53b 1-4c05-87... 7/8 2/22/2021 RAN Template: A8L Template: 56790EZ SR R 56790EZ SR R SE01451A Sprint Retain1draft_2021-02-22 SE01451A Sprint Retain_1_draft Section Z Power Systems Equipment nally blank. ----- T Print Name: Standard PORs: New Build_Sprint Keep https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/58774968-99f4-4dd6-a7c5-a46142f11 ff0?layoutld=2e5112cd-53b 1-4c05-87... 8/8