REVIEWED PLN_RESUB 2-Elevations and Details PlanC n E Q rn N N N O N ti O LL EL. 98.0 '--n //00' \ 100, ice/ • 0000 i CULVERT i WATER MAIN LINE TO HOUSE WATER METER AT STREET CORNER WATER MAIN LINE TO HOUSE ""-- EDGE OF ROAD ELECTRICITY GAS TELEPHONE SEWER WATER DIA. LEYL. C. FENCE UTILITY SEMENT TIMBER WALL FENCE OF EAVE STEM WALL 2" HT. ABV. RAMP SURFACE (TYPICAL) EXISITNG FRONT DOOR 5„ 72" �s.. CONCRETE RAMP SURFACE (7.8% MAX. SLOPE) CONCRETE PLANTE CONCRETE RAMP Q STEM WALL \-- EXISTING CONCRETE DRIVEWAY EXISTING NEW CONCRETE NATIVE SOIL GRAVEL PATH STAIRS 4" RISER, 15" TREAD COI FINISH GRADE @ LANDING AND RAK STEM WALL 2" HT. ABV. RAMP SURFACE (TYPICAL) EXISITNG FRONT DOOR CONCRETE RAMP SURFACE (7.8% MAX. SLOPE) NEW LANDING TO MATCH EXISTING ELEVATION @ DOOR THRESHOLD NEW STEPS WITH 4" RISE AND 15" TREAD EXISTING CONCRETE DRIVEWAY NATIVE SOIL STEP DOWN TO GRAVEL PATH (WEST) OD SOUTH ENTRY RAMP ELEVATION CE� EAST ENTRY RAMP ELEVATION NO SCALE NO SCALE CONCRETE STAIRS, 4" RISER / 15" TREAD, REINF. W/ #4 REBAR (TYP.), PIN TO WALL 2" PNTR. 8" CONCRETE WALL X 30" HT., 1" CHFR TOP & END FACE, REINF. W/ (4) #4 REBAR 12" O.C., 2" CLR. FROM EDGE TYP. PAVERS / LANDINGS AND RAMP (4" BELOW TOP OF WALL TYP.) 1" SAND LEVELING LAYER 4" 5/8" - GRAVEL (COMPACTED) RAMP a PLANTER _ RAMP LANDING J 1" PVC WEEP HOLE 1% SLOPE II CONCRETE FOOTING, 24"X10" DEEP, #4 REBAR 8" O.C., 2" CLR. FROM EDGE— TYP. 4" 5/8" - GRAVEL (COMPACTED) SUBGRADE FOOTING / RAMP DETAIL A NO SCALE WALL LIGHT 2" CLR. (TYP) /-- 3" MULCH LAYER 8" CONCRETE WALL X 30" HT., 1" CHFR TOP & END FACE, REINF. W/ (4) #4 REBAR 12" O.C., 2 " CLR. FROM EDGE TYP. FILTER FABRIC 4" DEPTH, 7/8" DRAIN ROCK BTWN. 1" PVC WEEP HOLE 1% SLOPE, 1" ABOVE F.G. CONCRETE FOOTING, 24"X10" DEEP, 4 #4 REBAR 8" O.C., 2" CLR. FROM EDGE • TYP. TOPSOIL . ; flfl CONCRETE TO MATCH EXISTING t SAWCUT TO RECIEVE FOOTING FILL �' EXISTING CONCRETE DRIVEWAY SUBGRADE 4" 5/8" - GRAVEL (COMPACTED) FOOTING / PLANTER WALL DETAIL CONTRACTORS NOTES: -THIS IS NOT A FORMAL SURVEY. PROPERTY INFORMATION CONTAINED HEREIN, CALCULATED FROM OWNERS DOCUMENTS, CITY RECORDS, & ON SITE OBSERVATIONS. -ALL CONSTRUCTION CONTRACTS SHALL BE BETWEEN HOMEOWNER AND CONTRACTOR EXCLUSIVELY. ARCHITECT/PROJECT MANAGER, ACTS AS AGENT FOR OWNER AND IS NOT RESPONSIBLE FOR PAYMENT TO CONTRACTORS. -CONTRACTOR OR OWNER MUST VERIFY ON SITE DIMENSIONS PRIOR TO PURCHASE OF MATERIALS OR CONSTRUCTION, AND INFORM OWNER OR LANDSCAPE ARCHITECT OF DISCREPANCIES. -CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION AND PROTECTION OF ALL UNDERGROUND UTILITIES AND SHALL ACCEPT FULL RESPONSIBILITY DUE TO NEGLIGENCE. -CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR STRUCTURAL INTEGRITY AND DURABILITY OF ALL ARCHITECTURAL AND LANDSCAPE CONSTRUCTION. -ALL CONSTRUCTION SHALL MEET BUILDING CODES AS THEY APPLY. -OWNER SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND PAYING ALL PERMIT FEES. LANDSCAPE ARCHITECT WILL ASSUME OWNER HAS OBTAINED ALL PERMITS UNLESS SPECIFICALLY INSTRUCTED BY OWNERS TO OBTAIN PERMITS ON THEIR BEHALF. -ROUGH GRADING SHALL BE INSPECTED BY LANDSCAPE ARCHITECT PRIOR TO COMPLETION. -ALL SALVAGEABLE MATERIALS AND ITEMS SHALL REMAIN PROPERTY OF OWNER. -ALL CONCRETE FORMWORK SHALL BE INSPECTED BY OWNER OR LANDSCAPE ARCHITECT PRIOR TO POUR. LIGHTING NOTES WER LINE - L indicates 12v. light location. TIMATED - L Use Vista 1503-AL-B-W-MV-PCT--CP-ER-1503-1 for recessed wall lights. Set 2" from top of wall. .PLANTER DCKEDGE Use transformer with astronomical clock on un-switched circuit. UTILITY Material Notes: SEMENT Concrete Planter and Entry Ramp Walls: Footings to be 12"x6" thick concrete with #4 rebar set as needed, min. 2" from face of concrete. Top of footing to be a min. of 4" below finish grade. Footing to be set over 4" of 5/8"- gravel compacted to 900, over a smooth firm sub grade. NO SCALE Planter box Walls to be natural color concrete with smooth form board finish, 8" wide and at height as noted on plan. Set all walls level. All exposed top and corner edges to have a 1" chamfer. Reinforce with #4 steel bar as needed and tie into footing. Provide 1" pvc weep hole for drainage in wall and set 1/2" above finish grade of driveway. Set recessed light fixture housing per manufacturers instructions 2" below top of wall and provide conduit for electrical connection. Use native soil to fill bottom of box to within 1" of weep holes. Cover soil with filter fabric and then cover with 4" drain rock above weep holes. Cover top of drain rock with filter fabric and fill with topsoil to within 6 " of top of planter. Ramp to be 4" natural color concrete over 4" s"- gravel compacted to 900 over smooth compacted base. Surface to be light broom finish swept cross slope. Provide cold tool control joints as noted on plan, cut min. 2" deep into surface of concrete. Curb to be 8" wide with structural steel as needed. Set top of curb 2" above surface of concrete ramp and follow grade of ramp. Exposed corners top and side to have 1" camphor. Finish to match walls. Concrete Stairs Stairs to be concrete natural color with #4 rebar as needed for reinforcement, over 4" of 5/8"- gravel compacted to 900, over a smooth firm sub grade. Dowel stairs into planter concrete wall and driveway. Treads to be 15" with 4" risers, light broom finish, parallel with treads. Seal concrete w/semi-gloss sealer after 28 day, or appropriate curing period. NORTH )I SCALE: 1 "=10'-0" REVISIONS: 1. 9-9-2021 2. 12-11-21 3. 1-28-22 4. 2-4-22 5. zCQ Co Cat-, 0 AW M CQ C?� Z E- O M O A CDCQ 0 to 0 CQ M z x >C LO co U) C\2 r l E­i H 91 LLJ F_ Z Z N CD Z =O � 00 � L0 a a Q Cl) O � J o z Q 0 � Q V � w H O U) Q w J � Z ao06 FM > < LU W� Cl) w w o DATE: 8-9-21 DESIGNED: RSL DRAWN: LEO LU JOB NO: SHEET: Om L1 ■ 2