Loading...
APPROVED PLN BLD ENG BLD2022-0178+Architectural_Plan+2.9.2022_2.05.29_PM+2671648ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department AT&T SITE AT&T SITE NUMBER. -- NAME: AT&T FA CODE: AT&T PACE SITE TYPE: NUMBER: SITE INFORMATION CROWN CASTLE USA INC. SITE NAME: SITE ADDRESS: COUNTY: MAP/PARCEL#: AREA OF CONSTRUCTION: LATITUDE: LONGITUDE: LAT/LONG TYPE: CURRENT ZONING: JURISDICTION: OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: A.D.A. COMPLIANCE: PROPERTY OWNER: TOWER OWNER: CARRIER APPLICANT: LAKE BALLINGER AL • WA6358 SAKE BALLINGER 10013429 MRWOR052984 / MRWOR052702 MONOPOLE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE BUSINESS UNIT #- S ITE ADDRESS: .000�.,=no�o,..,.,,.,� COUNTY: JURISDICTION-. Mar 02 2022 TWR/FAA APPROVED PROJECT: 5G NR 1 SR n77/3BU Expansion 23931 HIGHWAY 99 EDMONDS, WA 98026 SNOHOMISH 004519-002-015-04 EXISTING 47° 46' 54.30" (47.7817) —122° 20' 37.90" (-122.3439) (NAD 83) CG CITY OF EDMONDS U IIB FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION ARI HOLDINGS LLC 23931 HWY 99 EDMONDS,WA 98020 CROWN CASTLE USA Inc 2000 CORPORATE DRIVE CANONSBURG, PA 15317 AT&T TOWER ASSET GROUP 19801 SW 72ND AVENUE TUALATIN, OR 97062 PROJECT TEAM A&E FIRM: P. MARSHALL & ASSOCIATES 1000 HOLCOMB WOODS PKWY STE. 210 ROSWELL, GA 30076 PATRICK W MARSHALL, P.E. 678-280-2325 CROWN CASTLE USA 1505 WESTLAKE AVENUE NORTH, SUITE 800 INC. DISTRICT: SEATTLE, WA 98109 CONTACTS: JASON GIBSON — PROJECT MANAGER (615) 771-4313 CLINTON GRIFFETH — CONSTRUCTION MANAGER ROBERT FOREST — A&E SPECIALIST (917) 924-7092 AT&T CONTACT: TIM DOLLOWITCH 19801 SW 72ND AVENUE TUALATIN, OR 97062 (503) 569-7818 tim.dollowitch@caerusconsulting.net DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET & PROJECT INFORMATION T-2 GENERAL NOTES C-1.1 OVERALL SITE PLAN C-1.2 EXISTING & FINAL EQUIPMENT PLANS C-2 EXISTING & FINAL ELEVATIONS C-3 EXISTING & FINAL ANTENNA PLANS C-4 FINAL ANTENNA & CABLE SCHEDULE C-5 ELECTRICAL WIRING DIAGRAM C-6 EQUIPMENT DETAILS C-7 EQUIPMENT DETAILS C-8 EQUIPMENT DETAILS G-1 GROUNDING SCHEMATIC G-2 GROUNDING DETAILS ATTACHED PLUMBING DIAGRAM PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNA MODIFICATION ON AN EXISTING WIRELESS SITE. TOWER SCOPE OF WORK Both LTE & NR must be on the same CPRI Rate7. 1st LTE CPRI should be SFP7 (NEQ.20022) on both Radio and ABIA sides for AirScale RRH (AHLBA, AHLBBA, AHFIB, AHCA, AHNA) and SFP7 (CEQ.16446 or NEQ.20022) on both Radio and ABIA sides for ALU radios (UHFA, UHIE). The 2nd 5G CPRI should be SFP7 (NEQ.20022/NEQ.53020) on both Radio and ABIL/ABIO sides for Airscale and ALU radios. Add 2nd CPRI connection for all bands/radio that is missing. n77 Band requires (2) CPRI connections (CEQ.24407) on both Radio and ABIO sides. Contractor to maintain RRH to back of antenna clearance and 1314/1329 & n77 antenna separation per latest AT&T guidelines. • REMOVE (6) ANTENNAS • REMOVE (6) TMAs • INSTALL (3) ANTENNAS • INSTALL (1) RAYCAP SQUIDs • INSTALL (1) #6 AWG DC TRUNKS • MODIFY MOUNT • ISTALL SITE PRO 1 6CHMT COLLAR MOUNT FOR RRH MOUNTED 18" BELOW AT&T MOUNT GROUND SCOPE OF WORK • REMOVE ARGUS PDU & BATTERY CABINET • REMOVE POWER EQUIPMENT FROM EXISTING CONVERTER SHELF, REMOVE CONVERTER SHELF; TRANSFER LOADS TO NEW POWER PLANT • RE —CONFIGURE (10) EXISTING +24V BATTERY STRINGS TO (5) —48V BATTERY STRINGS FOR THE NEW PDU • INSTALL EMERSON BATTERY CABINET • INSTALL —48V EMERSON NETSURE 512 DC PLANT W/ (10) RECTIFIERS & (2) CONVERTER MODULES • UTILIZE EXISTING (1) ASIA AND (3) ABIA CARDS ON THE C1 SIDE FOR LTE. REMOVE EXISTING (1) ASIK AND (1) ABIL CARDS ON THE C2 SIDE. ADD (1) ASIL AND (2) ABIO CARDS TO THE C2 SIDE FOR 5G 850/1900/AWS, 5G C n77 ---------------------- ----- Work CELLULAR MODIFICATIONS ---------------------------------------------------------------------- --------------------------------------------------• Address 23931 HIGHWAY 99 - CELLULAR Owner. AT&T --------------- ------------------------ Approved Date 2/22/2022 --------------- --------------- Building Official DowaTrooL W. 1i cofALaAL ----------------------------------------------------------- Permit Number BLD2022-0178 23931 HIGHWAY 99 EDMONDS, WA 98026 SNOHOMISH CITY OF EDMONDS H GT-0 57.0'/64.0' APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2018 IBC MECHANICAL 2018 IMC ENGINEERING DIVISION ELECTRICAL 2020 NEC NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER HF'F'KUVtU W�� 02/09/2022 Protect storm drains from construction detritius. REFERENCE DOCUMENTS: RFDS ID: 4323785 APPLICATION ID: 565149 MOUNT ANALYSIS BY: B + T Group DATED: 06/28/21 CALL WASHINGTON ONE CALL (800)424-5555 CALL 3 WORKING DAYS BEFORE YOU DIG! AT&T QJ4CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 PD� O P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REV DATE DESCRIPTION A 7/16/21 PRELIMS 0 1/27/22 FOR CONSTRUCTION 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB G w"ofr DRAWN: JLB 0� CHECKED: PWM "a�po 901/27/2022 k� +' sG UBI NUMBER: 604-106-184 JOB #: 21 CCA06M-0080 TITLE SHEET & PROJECT INFORMATION u 0 zo: Tml CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CARRIER: AT&T CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. TOWER OWNER: CROWN CASTLE USA INC. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS METHODS TECHNIQUES, Q SEQUENCES,AND PROCEDURES. CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS 3. PRIOR TO THE START OF CONSTRUCTION ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES BUT Q REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ONLY. ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO TO LOCAL JURISDICTIONAL REQUIREMENTS. DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC. VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR STANDARD CED-STD-10253 INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV Q CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS CASTLE USA INC. TOWER SITE" AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND OF INSTALLATION. LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS REGULATIONS. AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. SPECIFICALLY STATED OTHERWISE. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN UNLESS SPECIFICALLY STATED OTHERWISE. ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. INSTALLATION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED CONSTRUCTION SAFETY PROCEDURES. FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE CONCRETE, FOUNDATIONS, AND REINFORCING STEEL: REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. APPLICATION. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90°f AT TIME OF PLACEMENT. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM CONTROL. WATER -TO -CEMENT RATIO (W/C) OF 0.45. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED #4 BARS AND SMALLER 40 ksi LOCATION. #5 BARS AND LARGER 60 ksi 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: BASIS. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT CONCRETE EXPOSED TO EARTH OR WEATHER: BE PLACED IN ANY FILL OR EMBANKMENT. #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1-1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLAB AND WALLS 3/4" BEAMS AND COLUMNS 1-1 /2" 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. GREENFIELD GROUNDING NOTES: 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL- OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). ELECTRICAL INSTALLATION NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1 /2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TIC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75` C (90° C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "AT&T" 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/240V, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/480V, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED** NEG (-) BLACK** * SEE NEC 210.5(C)(1) AND (2) ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION TEMPORARY SURVEY MARKINGS ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS POTABLE WATER RECLAIMED WATER, IRRIGATION, AND SLURRY LINES SEWERS AND DRAIN LINES AT&T QjCROWN %. CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL &ASSOCIATES BU �: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REV I DATE I DESCRIPTION A 1 7/16/21 I PRELIMS 0 1 1/27/22 I FOR CONSTRUCTION 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB G w"o;,4% ovw' _ I DRAWN: JLB wd�� jj�#4�0 s`sj�NAL�G 01 /27/2022 UBI NUMBER: 604-106-184 CHECKED: PWM JOB #: 21 CCA06M-0080 GENERAL NOTES Tm2 W LEGAL DESCRIPTION: FRUITLAND ACRES TO LAKE BALLINGER BLK 002 D-04 — BEG AT INT E LN ST RD 1 AS PREVIOUSLY DEEDED & S LN LOT 15 SD PLAT TH E 200 FT TH NLY AT R/A 100 FT TH WLY & PLT S LN LOTS 15 & 16 TO ST RD 1 AS PREVIOUS— LY DEEDED TH SWLY ALG SD RD TO POBLESS S/HY N S E u 0 f 131 TOWER SETBACK APPROXIMATE LOCATION OF PROPERTY LINE EXISTING SITE LOCATION — SEE SHEET C-1.2 FOR DETAILS SUBJECT PARCEL: 00451900201504 ZONING: GC EXISTING Fill EXISTING BUILDING BUILDING EXISTING - BUILDING / r\/IC`TIAin -rm rr �T\/fl AT&T CROWN wo�, CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 p 0 O P. MARSHALL &ASSOCIATES EXISTING EXISTING % EXISTING BUILDING BUILDING xx BUILDING '- /''�/ �\ Oki WA6358 ±30' TOWER i SETBACK i -"'� APPROXIMATE LOCATION OF PROPERTY LINE 0. l0ril 1 � `din EXISTING BUILDING VmV OVERALL SITE PLAN T 1 1 1 1 1 .1 1 -RS PROPERTY IYP.) SITE PLAN DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM JURISDICTIONAL GIS. CROWN CASTLE USA INC. HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REVI DATE A 1 7/16/21 0 1 1 /27/22 DESCRIPTION PRELIMS FOR CONSTRUCTION 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB G w �" w'°� DRAWN: JLB coC t-- CHECKED: PWM 1.6 55499 k� ssj�NALE�Cs 01 /27/2022 UBI NUMBER: 604-106-184 JOB #: 21 CCA06M-0080 OVERALL SITE PLAN CA A NOTE: EQUIPMENT LAYOUT SHOWN IS BASED ON THE PREVIOUS CONSTRUCTION DRAWINGS DONE BY CROWN CASTLE DATED 4/8/20 AS WELL AS MOST RECENT AUDIT PHOTOS AND MEASUREMENTS. IF EQUIPMENT LAYOUT DIFFERS FROM WHAT IS SHOWN, CONTRACTOR TO CONTACT THE CONSTRUCTION MANAGER. EXISTING AT&T ICE BRIDGE (+/-10'-0") EXISTING CARRIER EQUIPMENT PAD EXISTING MONOPOLE EXISTING AT&T ICE BRIDGE (+/-12'-0") EXISTING AT&T FEEDLINES (18) 7/8" COAX CABLES (4) #8 AWG DC TRUNKS - (2) FIBER TRUNK - (1) RET / EXISTING AT&T ICE BRIDGE (+/-10'-0") EXISTING CARRIER EQUIPMENT PAD EXISTING RAYCAP DC 12 (LTE) EXISTING MONOPOLE EXISTING AT&T ICE BRIDGE (+/-12'-0") EXISTING AT&T FEEDLINES (18) 7/8" COAX CABLES (4) #8 AWG DC TRUNKS - (2) FIBER TRUNK - (1) RET PROPOSED AT&T (1) #6 AWG DC TRUNK(S) EXISTING CABLE TRAY EXISTING MINI-PURCELL FLX16 W/ vvr.ih FSM4 FSM4(AMIA) EXISTING RAYCAP DC12 (LTE) EXISTING AT&T POWER METER PANEL EXISTING GENERATOR INTERFACE ENCLOSURE SUB PANEL 1 EXISTING NOKIA GSM CABINET 1 � 1 EXISTING CABLE TRAY EXISTING MINI-PURCELL FLX16 W/ ivvr.ir FSM4 FSM4(AMIA) ASI T PAI PANEL EXISTING GENERATOR INTERFACE ENCLOSURE EWME/00/0. 1 1 � 1 EXISTING ARGUS TE21 +24V DC POWER PLANT & BATTERIES T J/ i REMOVE POWER EQUIPMENT FROM EXISTING CONVERTER SHELF, REMOVE CONVERTER SHELF; TRANSFER LOADS TO NEW POWER PLANT EXISTING ARGUS TE43 CABINET W/ RAYCAP DC6 (LTE), RAYCAP DC12 (LTE), -48V CONVERTER SHELF, SAID, CCU, & FIBER SLACK TRAY EXISTING ARGUS TE40 BATTERY CABINET TO BE REMOVED \L EXISTING UMTS CABINET EXISTING DIPLEXERS EXISTING AT&T 14'-6" x 16'-0" PAD EXISTING JUNCTION BOXES EXISTING +24v DC POWER PLANT TO BE REMOVED - BATTERIES TO REMAIN EXISTING ARGUS TE43 CABINET W/ RAYCAP DC6 (LTE), RAYCAP DC12 (LTE). CCU. & FIBER SLACK TRAY PROPOSED EMERSON BATTERY CABINET EXISTING UMTS CABINET EXISTING DIPLEXERS W BATTERY NOTE: s RECONFIGURE (10) +24V STRINGS AS (5) -48V STRINGS AT FINAL. EXISTING FSM4 (AMIA) - UTILIZE EXISTING (1) ASIA AND (3) ABIA CARDS ON THE Cl SIDE FOR LTE. REMOVE EXISTING (1) ASIK AND (1) ABIL CARDS ON THE C2 SIDE. ADD (1) ASIL AND (2) ABIO CARDS TO THE C2 SIDE FOR 5G 850/1900/AWS, 5G C n77 EXISTING JUNCTION BOXES EXISTING AT&T 14'-6" x 16'-0" PAD PROPOSED -48V EMERSON NETSURE 512 DC PLANT W/ (10) RECTIFIERS & (2) CONVERTER MODULES INSTALLER NOTE: QjCROWN t4ow CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 [ppm P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REV I DATE DESCRIPTION E A 7/16/21 PRELIMS CROWN CASTLE HAS BEEN INFORMED BY THE CARRIER THAT THE REMOVAL OF THE EXISTING EQUIPMENT AND REPLACEMENT WITH NEW EQUIPMENT WILL NOT INVOLVE ANY MODIFICATION OR UPGRADES TO THE EXISTING AC ELECTRICAL SYSTEM AND THAT THE PROPOSED EQUIPMENT WILL UTILIZE THE SAME BREAKER, WIRE, AND CONDUIT THAT WAS USED FOR THE EQUIPMENT BEING REPLACED. THE CONTRACTOR IS TO NOTIFY THE ENGINEER OF RECORD IF ANY ELECTRICAL MODIFICATIONS TO THE EXISTING AC ELECTRICAL SYSTEM ARE NECESSARY FOR THE REQUESTED WORK TO BE PERFORMED. 0 1/27/22 FOR CONSTRUCTION w7T" - 01 /27/2022 UBI NUMBER: 604-106-184 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 EXISTING &FINAL EQUIPMENT PLANS CA m2 CVICTIKI(` AT9,.T F:-nl IIDKA1 -NIT Tn REMAIN NinTF-c- 1. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DO NOT EXCEED BEACON BASE HEIGHT. MOUNT ANALYSIS NOTES: ,YCAP SQUID 1. THE DESIGN DEPICTED IN THESE DRAWINGS IS VALID WHEN ACCOMPANIED BY A CORRESPONDING PASSING BE REMOVED MOUNT ANALYSIS. I-ENNAS 2. CONSTRUCTION MANAGER / GENERAL CONTRACTOR SHALL )65C ANTENNAS REVIEW THE MOUNT ANALYSIS FOR ANY CONDITIONS PRIOR TMA's TO INSTALLATION. 3. ANY REQUIRED MOUNT MODIFICATION DESIGN OR MOUNT REPLACEMENT SHALL BE APPROVED BY EOR. EXISTING SOUTH ELEVATION NOT TO SCALE J CD J Q Q 0 0 nLo F- 2 C� Of W �J 2 � O F— c� z z z ~ w N F— x z w Q Li-- -1 O z 0- 0 Lo 06 Lo CO Lo 0 e 0 0 0 0 0 0 0 0 0 e 0 0 0 0 EXISTING AT&T EQUIPMENT TO REMAIN - (6) ANTENNAS - (12) RRH - (2) DC6-48-60-18-8F RAYCAP SQUID AT&T EQUIPMENT TO BE INSTALLED — (3) NOKIA AEQK ANTENNAS — (1) DC9-48-60-24-8C—EV RAYCAP SQUID EXISTING AT&T PLATFORM MOUNT TO BE UPGRADED/MODIFIED PER THE MOUNT ANALYSIS • INSTALL (2) STANDOFF MOUNTS (SITEPRO1 #WWM02 — HSS4X4X4 — 2'-0" LONG), ATTACHED TO THE EXISTING PLATFORM FACE HORIZONTAL CHANNEL AND THE REINFORCING FACE HORIZONTAL PIPE WITH NEW ANTENNA MOUNTING PIPE 2" STD X 6'-0" ATTACHED TO THE NEW STANDOFF MOUNTS, NEAR POSITION #3 AT GAMMA SECTOR. • MOVE EXISTING ANTENNA MOUNTING PIPE OF POSITION #3 AT ALPHA SECTOR, 1 '-9 " TOWARDS POSITION #4. PROPOSED SITE PRO 1 6CHMT COLLAR MOUNT FOR RRH MOUNTED 18" BELOW AT&T MOUNT PROPOSED AT&T (1) #6 AWG DC TRUNK(S) EXISTING AT&T FEEDLINES — (18) 7/8" COAX CABLES — (4) #8 AWG DC TRUNKS — (2) FIBER TRUNK — (1) RET EXISTING MONOPOLE FINAL SOUTH ELEVATION NOT TO SCALE AT&T CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REVI DATE A 1 7/16/21 0 1 1 /27/22 DESCRIPTION PRELIMS FOR CONSTRUCTION W7T" - 01 /27/2022 UBI NUMBER: 604-106-184 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 EXISTING & FINAL ELEVATIONS Cm2 NOTE: EQUIPMENT LAYOUT SHOWN IS BASED ON THE PREVIOUS CONSTRUCTION DRAWINGS DONE BY CROWN CASTLE DATED 4/8/20 AS WELL AS MOST RECENT AUDIT PHOTOS AND MEASUREMENTS. IF EQUIPMENT LAYOUT DIFFERS FROM WHAT IS SHOWN, CONTRACTOR TO CONTACT THE CONSTRUCTION MANAGER. EXISTING AT&T ANTENNAS TO BE REMOVED COMMSCOPE SBNHH-lD65C (TOTAL OF 3, 1 PER SECTOR) LTE --- 270° EXISTING AT&T RRH TO REMAIN NOKIA RRH4X25-WCS-4R (TOTAL OF 3, 1 PER SECTOR) U MTS g--- EXISTING AT&T RRH TO REMAIN 270° NOKIA 4T4R B12/14 AHLBA (TOTAL OF 3, 1 PER SECTOR) EXISTING AT&T RRH TO REMAIN NOKIA 4T4R B25/66 AHFIB (TOTAL OF 3, 1 PER SECTOR) 5G 270° EXISTING PLATFORM MOUNT TO REMAIN EXISTING AT&T RRH TO REMAIN NOKIA RRH4X25—WCS-4R (TOTAL OF 3, 1 PER SECTOR) LTE 270° o EXISTING AT&T ANTENNAS TO REMAIN COMMSCOPE NNH4-65C—R6 (TOTAL OF 6, 2 PER SECTOR) — GAMMA POSITION 2, RELOCATE TO POSITION 4 — BETA POSITION 1, RELOCATE TO POSITION 4 EXISTING AT&T RAYCAP DC6-48-60-18-8F TO REMAIN (TOTAL OF 2, 1 PER ALPHA & GAMMA SECTOR) EXISTING AT&T TMAs TO BE REMOVED POWERWAVE LGP21401 (TOTAL OF 6, 2 PER SECTOR) A�' EXISTING AT&T RRH TO REMAIN NOKIA 4T4R B5 AHCA (TOTAL OF 3, 1 PER SECTOR) EXISTING AT&T ANTENNAS TO BE REMOVED KATHREIN 742-265 (TOTAL OF 3, 1 PER SECTOR) lorfildKolm 1. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DO NOT EXCEED BEACON BASE HEIGHT. MOUNT ANALYSIS NOTES: 1. THE DESIGN DEPICTED IN THESE DRAWINGS IS VALID WHEN ACCOMPANIED BY A CORRESPONDING PASSING N MOUNT ANALYSIS. EXISTING ANTENNA PLAN 2. CONSTRUCTION MANAGER / GENERAL CONTRACTOR SHALL 1 "=3'—O" (FULL SIZE) REVIEW THE MOUNT ANALYSIS FOR ANY CONDITIONS PRIOR KL7TO INSTALLATION. 3' 1.5' 0 3' 1 "=6'-0" (l l xl7) 3. ANY REQUIRED MOUNT MODIFICATION DESIGN OR MOUNT REPLACEMENT SHALL BE APPROVED BY EOR. PROPOSED AT&T ANTENNAS NOKIA AEQK (TOTAL OF 3, 1 PER SECTOR) hC� /6\/^� G1 LTE/5G 270° PROPOSED AT&T RAYCAP DC9-48-60-24-8C-EV (TOTAL OF 1, BETA SECTOR) LTE -06----- 270° EXISTING AT&T RRH TO REMAIN NOKIA 4T4R B12/14 AHLBA (TOTAL OF 3, 1 PER SECTOR) EXISTING AT&T RRH TO REMAIN NOKIA 4T4R B25/66 AHFIB (TOTAL OF 3, 1 PER SECTOR) 513 270° 64 U 82 0 A4 o° h�i O G2 A2 \ �r EXISTING AT&T PLATFORM MOUNT TO BE UPGRADED/MODIFIED PER THE MOUNT ANALYSIS • INSTALL (2) STANDOFF MOUNTS (SITEPR01 #WWM02 - HSS4X4X4 - 2'-0" LONG), ATTACHED TO THE EXISTING PLATFORM FACE HORIZONTAL CHANNEL AND THE REINFORCING FACE HORIZONTAL PIPE WITH NEW ANTENNA MOUNTING PIPE 2" STD X 6'-0" ATTACHED TO THE NEW STANDOFF MOUNTS, NEAR POSITION #3 AT GAMMA SECTOR. • MOVE EXISTING ANTENNA MOUNTING PIPE OF POSITION #3 AT ALPHA SECTOR, 1 '-9 " TOWARDS POSITION #4. EXISTING AT&T RAYCAP DC6-48-60-18-8F TO REMAIN (TOTAL OF 2, 1 PER ALPHA & GAMMA SECTOR) lc�/ / e G4 EXISTING AT&T ANTENNAS TO REMAIN COMMSCOPE NNH4-65C—R6 (TOTAL OF 6, 2 PER SECTOR) GAMMA POSITION 2, RELOCATE TO POSITION 4 — BETA POSITION 1, RELOCATE TO POSITION 4 EXISTING AT&T RRH TO REMAIN NOKIA 4T4R B5 AHCA (TOTAL OF 3, 1 PER SECTOR) PROPOSED SITE PRO 1 6CHMT COLLAR MOUNT FOR RRH MOUNTED 18" BELOW AT&T MOUNT AT&T CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REVI DATE A 1 7/16/21 0 1 1 /27/22 DESCRIPTION PRELIMS FOR CONSTRUCTION W7T" - 01 /27/2022 UBI NUMBER: 604-106-184 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 EXISTING &FINAL ANTENNA PLANS Cm3 NOTES: 1. REFER TO FINAL RFDS FOR FINAL RF CONFIGURATION. ALPHA FINAL EQUIPMENT SCHEDULE (VERIFY WITH CURRENT RFDS) ANTENNA RADIO DIPLEXER TMA SURGE PROTECTION CABLES POSITION TECH. STATUS/MANUFACTURER MODEL AZIMUTH RAD CENTER QTY. STATUS/MODEL LOCATION QTY. STATUS LOCATION QTY. STATUS/MODEL QTY. STATUS/MODEL QTY. STATUS/TYPE LENGTH Al LTE/5G (E) COMMSCOPE NNHH-65C-R4 160' 56' 1 (E) 4T4R B5 AHCA TOWER - - - - - - - - - - 1 (E) RRH4X25-WCS-4R TOWER A2 LTE (E) COMMSCOPE NNH4-65C-R6 160° 56' 1 (E) 4T4R B12/14 AHLBA TOWER - - - - - 1 (E) DC6-48-60-18-8F 2 (E) #8 AWG DC 80'-0" 1 (E) 4T4R B25/66 AHFIB TOWER 1 (E) FIBER 80'-0" A3 - - - - - - - - - - - - - - 6 (E) 7/8" COAX 80'-0" 1 (E) RET 80'-0" A4 5G (P) NOKIA AEQK 160' 58.75' - - - - - - - - - - - - - BETA B1 5G (P) NOKIA AEQK 270' 58.75' - - - - - - - - - - - - - B2 LTE (E) COMMSCOPE NNH4-65C-R6 270° 56' 1 (E) 4T4R B12/14 AHLBA TOWER 1 (P) DC9-48-60-24-8C-EV 1 (P) #6 AWG DC 80'-0" 1 (E) 4T4R B25/66 AHFIB TOWER B3 - - - - - - - - - - - - - - 6 (E) 7/8" COAX 80'-0" B4 LTE/5G (E) COMMSCOPE NNHH-65C-R4 270° 56' 1 (E) 4T4R B5 AHCA TOWER - - - - - - - - - - 1 (E) RRH4X25-WCS-4R TOWER GAMMA G1 LTE/5G (E) COMMSCOPE NNHH-65C-R4 30' 56' 1 (E) 4T4R B5 AHCA TOWER - - - - - - - - - - 1 (E) RRH4X25-WCS-4R TOWER G2 5G (P) NOKIA AEQK 30' 58.75' - - - - - - - - 1 (E) DC6-48-60-18-8F 2 (E) #8 AWG DC 80'-0" 1 (E) FIBER 80'-0" G3 - - - - - - - - - - - - - - 6 (E) 7/8" COAX 80'-0" G4 LTE (E) COMMSCOPE NNH4-65C-R6 30° 56' 1 (E) 4T4R B12/14 AHLBA TOWER - - - - - - - - - - 1 (E) 4T4R B25/66 AHFIB TOWER NOTE: (E) — EXISTING (P) — PROPOSED Voltage Drop Calculations Voltage (V) = 48 Amperage (A) = 10.00 1 Temperature (°C) = 75 Power Plant to DC-6 (Jumper) DC-6 to Squid (Trunk) Squid to RRH (Jumper) Final Voltage Total Voltage Sector Wire Size Wire Length (ft) R (S2/kft) Voltage Drop I Wire Size Wire Length (ft) R (S2/kft) Voltage Drop Wire Size Wire Length (ft) R (S2/kft) Voltage Drop M Drop ( ) Alpha 8 15 0.7780 0.2334 6 80 0.4910 0.7856 8 15 0.7780 0.2334 46.75 2.61 Beta 8 15 0.7780 0.2334 6 80 0.4910 0.7856 8 15 0.7780 0.2334 46.75 2.61 Gamma 8 15 0.7780 0.2334 6 80 0.4910 0.7856 8 15 0.7780 0.2334 46.75 2.61 NOTES: 1. CALCULATIONS ARE BASED ON STRANDED, COPPER CONDUCTORS. 2. RESISTANCE VALUES FOR CONDUCTORS ARE BASED ON TABLE 8 OF THE NEC, DIRECT -CURRENT RESISTANCE FOR CONDUCTORS. 3. LENGTH SHOWN IS THE LENGTH ONE-WAY TO DEVICE. FINAL ANTENNA & CABLE SCHEDULE CABLE TOTALS 18 COAX 7/8" 80'-0" 1 DC #6 AWG 80'-0" 4 DC #8 AWG 80'-0" 2 FIBER 3/8" 80'-0" 1 RET 3/8" 80'-0" v u AT&T CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL &ASSOCIATES WA6358 BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REVI DATE A 1 7/16/21 0 1 1 /27/22 DESCRIPTION PRELIMS FOR CONSTRUCTION W7Tv - 01/27/2022 UBI NUMBER: 604-106-184 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 FINAL ANTENNA & CABLE SCHEDULE Cm4 JUMPERS (TYP) (2) FIBER JUMPER PAIR (TYF TO ANTENNAS (PER SECTOR) i I F '011 L — — — — — — — — — — ALARM CABLE I P P (TYP) L-- F-----F-----F--- P P P DC CONDUCTOR BUNDLE (TYP) 48VDC BUS INSIDE EXISTING POWER PLANT SET OF (2) DC CONDUCTOR BUNDLES (TYP) POWER PLANT P -Ti F F � P -- ----- P P ----- — --J F F F FIBER TRUNK DC POWER TRUNKS — P P AT&T QjCROWN %. CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 p 0 O P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REV DATE DESCRIPTION A 7/16/21 PRELIMS 0 1/27/22 FOR CONSTRUCTION 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DC 6 or 12 TOWER MOUNTED RRH SCENARIO - NOT SITE SPECIFIC DC WIRING DIAGRAM (PROVIDED BY OTHERS) SCALE: NOT TO SCALE NOTES: 1. REFER TO CHART FOR CABLE QUANTITIES, SIZES, AND LENGTHS. W7T" - 01 /27/2022 UBI NUMBER: 604-106-184 DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 ELECTRICAL WIRING DIAGRAM Cm5 10.24" PROPOSED RAYCAP DC "SQUID" OVERVOLTAGE PROTECTION UNIT (TYP.) PROPOSED RAYCAP MOUNTING BRACKET (TYP.) PROPOSED RAYCAP BASE PORTS (TYP.) PROPOSED RAYCAP CABLE SUPPORT HARNESS (TYP.; RAYCAP SQUID MOUNT DETAIL NOT TO SCALE NOT USED NOT TO SCALE -8C-EV LBS. +MOUNT 10.2 LBS.) 11 EXISTING MONOPOLE TOWER (TYP.) SECURE RAYCAP MOUNTING BRACKET TO MONOPOLE FACE WITH VALMONT STAINLESS STEEL BANDING STRAP (PART #61769) AND TENSION BUCKLES (PART #131770) OR STRUCTURAL EQUIVALENT (TYP.) NOT USED NOT TO SCALE ANTENNA DETAI L NOT TO SCALE NOT USED NOT TO SCALE ANTENNA MOUNT PIPE ANTENNA DOWNTILT BRACKET (SUPPLIED WITH ANTENNA) MOUNTING BRACKET (SUPPLIED WITH ANTENNA) AT&T CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 p 0 -.0& P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REV DATE DESCRIPTION A 7/16/21 PRELIMS 0 1/27/22 FOR CONSTRUCTION W7T" - 01 /27/2022 UBI NUMBER: 604-106-184 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 EQUIPMENT DETAILS Cm6 MANUFACTURER: Site Pro 1 MANUFACTURER: Nokia MANUFACTURER: Nokia MODEL: Airscale AEQK MAA n77 MODEL: 474293A, 19US806081A20A MODEL: DCP12K HEIGHT: 29.5" (750 mm) MAX FPKA SUPPORTED WEIGHT: 352.7 Ibs (160 kg) WEIGHT: 27.01 Ibs (12.3kg) WIDTH: 17.7 450 mm DEPTH: 9.5" 242 mmAT&T WEIGHT: 99.2 Ibs (45 kg) O ANTENNA SIDE (TYP.) �- CROWN FA Al CASTLE o RRH AZ:7- MIDDLE RRH p p p0 MOUNT LOCATION 1505 WESTLAKE AVENUE NORTH, SUITE 800 0 (SEE NOTE 1) 6j" SEATTLE, WA 98109 FPKA (TYP) ° D 0 = UPC1 w AMFDf I ° (TYP.) r O ANTENNA/RRH 0 RRH MOUNTING PIPE P. MARSHALL & ASSOCIATES MAST PIPE 0 2-3/8" MIN. ANTENNA o ® MOUNT PIPE 04 RRH ANTENNA RF CONNECTIONS � p (TYP) � SIDE ° WA6358 WIDTH o 0 O 0 TOP VIEW p o 0 000 ° PIPE TO PIPE CLAMP BU #: 840470 ADDITIONAL MOUNT NOTES: ACCOMMODATES 1Y4" TOP VIEW LAKE BALLINGER LOCATIONS (TYP) 1. INSTALLING THIRD RRH ON MIDDLE MOUNT TO 4Y2" O PIPE = LOCATION REQUIRES CAST LEGACY SPACERS. 23931 HIGHWAY 99 o SECTION A -A 2. ADDITIONAL RRHs NOT SHOWN IN ISO VIEW EDMONDS, WA 98026 FOR CLARITY. Nokia Airscale AEQK MAA n77 r2NOKIA FPKA — AMFD AirScale 2 FPKx Fixing Adapter Site Pro 1 DCP12K — Pipe To Pipe Clamp 3 - NOT TO SCALE - NOT TO SCALE - NOT TO SCALE REV DATE DESCRIPTION A 7/16/21 PRELIMS MANUFACTURER: SITEPRO MODEL: 6CHMT 0 1/27/22 FOR CONSTRUCTION PROPOSED RRU WITH MOUNTING WEIGHT: 272LBS HARDWARE AT FPKA MOUNT (TYP.) PROPOSED 2-3/8" 0 OD MOUNTING PIPE RECEIVED 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROPOSED 2-3/8"0 OD PROPOSED SITE PR01 DCP12K MOUNTING PIPE PIPE TO PIPE MOUNT (TYP.) DESIGNED: JLB wultpjT DRAWN: JLB CHECKED: PWM 55949 JOB #: EXISTING MOUNT FRAME NAL o�i2�i2o22 21 CCA06M-0080 (TYP.) ,J UBI NUMBER: 604-106-184 EQUIPMENT DETAILS PROPOSED SITE PR01 P/N: BBPM-K1 PIPE MOUNT KIT RRH MOUNTING AT MOUNT FRAME 4 5 Site Pro 1 6CHMT — Collar Mount Cm7 - NOT TO SCALE AT&T No. NEQ.15917 TECHNICAL SPECIFICATIONS DC POWER SYSTEM FEATURES NOMINAL SYSTEM VOLTAGE —48VDC OR +24VDC CONTROL MICROPROCESSOR (ACU+) RATED OUTPUT CAPACITY — MAXIMUM CONFIGURATION SYSTEM 550 AMPS AT —48VDC PLUS REDUNDANCY 400 AMPS AT +24VDC PLUS REDUNDANCY RECTIFIER 2000 WATTS (41.7A) CONVERTER 1200 WATTS (50A), —48VDC TO +24VDC DISTRIBUTION PANEL (TOP) WIRED FOR (16) +24V AND (13) —48V BULLET POSITIONS (BOTTOM) (30) —48V BULLET POSITIONS ENVIRONMENTAL OPERATING TEMPERATURE —407 TO 1157 (-40°C TO 46°C) CONTINUOUS OPERATION HUMIDITY 0% TO 95% RELATIVE HUMIDITY, NON —CONDENSING NEMA ENCLOSURE 3R II:I1:4NAI_1t.`111to] IItI l POWER CHAMBER 2500 WATT DOOR —MOUNTED HEAT EXCHANGER, 2RU AVAILABLE SPACE FOR SURGE PROTECTION BATTERY CHAMBER FAN COOLED, FRESH AIR VENTILATION, HOLDS UP TO (3) BATTERY STRINGS EQUIPMENT GROUND BAR 10 POSITIONS TERMINAL BLOCK 12—POSITION PHOENIX ALARM BLOCK, 32—POSITION PHOENIX ALARM BUNCHING BLOCK SAFETY DC POWER SYSTEM UL 1801 LISTED (US & CANADA), NEBS LEVEL 3 ENCLOSURE GR-487, UL 60950, AND SEISMIC ZONE 4 COMPLIANT WEIGHT OUTDOOR NetSureTM 512 816lbs (W/O BATTERIES) 2400lbs (W/ MARATHON 180 AH BATTERIES) PLINTH TBD CLEARANCES FRONT 36" LEFT AND RIGHT 0" REAR 12" 62.90" 1[�l��/lad►►I 39.0q'° LEFT SIDE VIEW * POWER CABINET TO INCLUDE EMERSON SM—TEMP TEMPERATURE CONCENTRATOR PIN 547490 OR EQUIVALENT AND BE CONNECTED TO BATTERY STRINGS BY TEMPERATURE PROBES (PN 556155 OR PIN 552992) 31.81" FRONT VIEW EMERSON OUTDOOR NETSURE 512 DC POWER SYSTEM SCALE: NOT TO SCALE MANUFACTURER: MODEL: HEIGHT: WIDTH: DEPTH: WEIGHT: EMERSON 72013065 36" 37" 1080 Ibs (w/o BATTERIES OR EQUIPMENT) 3>» COMPONENT ISO VIEW EMERSON F2013065 NOT TO SCALE 17.50" 3.0" 0 (6 TYP) 1.0" 0 (6 TYP) OPTIONAL PLINTH CABINET MOUNTING TEMPLATE SCALE: NOT TO SCALE H EAT EXCHANGER c c c I1 A -7 7 19 rmuru3tu I / z ui/-\IvIETER, SIMPSON STRONG —TIE STRONG —BOLT 2 STAINLESS STEEL WEDGE ANCHOR WITH 3-3/4" NOMINAL EMBEDMENT (ICC ESR-3037). TO BE INSTALLED IN EACH CORNER OF CABINET (4 TOTAL) WITH MINIMUM 6.5" EDGE DISTANCE. BASE BOLT PATTERN COMPARTMENT w/5 BATTERY SHELVES, 10—POSITION GROUND BAR, 8c 12—PAIR PHOENIX BLOCK I�VIVI�I\LIL JL/",U MAX CAPACITY: (6) —48V BATTERY STRINGS (VLRA BATTERIES) THERMOELECTRIC COOLING/HEATING CABINET ANCHOR DETAIL SCALE: NOT TO SCALE —_— LNG —BOLT 2 aL EMBEDMENT (ICC 8INET (4 TOTAL) IIPMEW E FRAME Z_ z. cn w z U_ 2 ii T AT&T CROWN Qj%w CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REVI DATE A 1 7/16/21 0 1 1 /27/22 DESCRIPTION PRELIMS FOR CONSTRUCTION W7T" — 01 /27/2022 UBI NUMBER: 604-106-184 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 EQUIPMENT DETAILS CM8 NEW ANTENNA AND/OR RADIO EQUIPMENT (SEE SHEET C-3 FOR MODEL AND QUANTITY) SECTOR GROUND BAR L__ TOWER GROUND RING NEW ANTENNA AND/OR RADIO EQUIPMENT (SEE SHEET C-3 FOR MODEL AND QUANTITY) SECTOR GROUND BAR TOWER TOP COLLECTOR GROUND BAR MIDPOINT GROUND BAR (AS NEEDED) TOWER EXIT GROUND BAR EXISTING EQUIPMENT AREA NEW ANTENNA AND/OR RADIO EQUIPMENT (SEE SHEET C-3 FOR MODEL AND QUANTITY) SECTOR GROUND BAR J EQUIPMENT GROUND RING _ --I NEW GROUND EQUIPMENT (SEE SHEET C-1.2 FOR MODEL AND QUANTITY) SURGE SUPPRESSION DEVICE J 0- GROUNDING PLAN LEGEND: GROUND WIRE C��(�lWa:��l[�L►Ia�17 • MECHANICAL CONNECTION 00 COPPER GROUND ROD GROUND ROD W/ TEST WELL CELL REFERENCE GROUND BAR: POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT FRAMES. ALL BONDS ARE MADE WITH #2 STRANDED GREEN INSULATED COPPER CONDUCTORS. BOND TO GROUND RING WITH (2) #2 SOLID TINNED COPPER CONDUITS (ATT-TP-76416 7.6.7). HATCH PLATE GROUND BAR: BOND TO THE INTERIOR GROUND RING WITH (2) #2 STRANDED GREEN INSULATED COPPER CONDUCTORS. WHEN A HATCH -PLATE AND A CELL REFERENCE GROUND BAR ARE BOTH PRESENT, THE CELL SITE REFERENCE GROUND BAR MUST BE CONNECTED TO THE HATCH -PLATE AND TO THE INTERIOR GROUND RING USING (2) #2 STRANDED GREEN INSULATED COPPER CONDUCTORS. EXTERIOR CABLE ENTRY PORT GROUND BARS: LOCATED AT THE ENTRANCE TO THE CELL SITE BUILDING. BOND TO GROUND RING WITH A #2 SOLID TINNED COPPER CONDUCTORS WITH AN EXOTHERMIC WELD AND INSPECTION SLEEVE (ATT-TP-76416 7.6.7.2). DURING ALL DC POWER SYSTEM CHANGES INCLUDING DC SYSTEM CHANGE OUTS, RECTIFIER REPLACEMENTS OR ADDITIONS, BREAKER DISTRIBUTION CHANGES, BATTERY ADDITIONS, BATTERY REPLACEMENTS AND INSTALLATIONS OR CHANGES TO DC CONVERTER SYSTEMS IT SHALL BE REQUIRED THAT SERVICES CONTRACTORS VERIFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH MASTER DC SYSTEM RETURN GROUND CONDUCTOR FROM THE DC POWER SYSTEM COMMON RETURN BUS DIRECTLY CONNECTED TO THE CELL SITE REFERENCE GROUND BAR PER TP76300 SECTION H 6 AND TP76416 FIGURE 7-11 REQUIREMENTS. u u AT&T QjCROWN q,,, CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 p 0 O P. MARSHALL &ASSOCIATES BU #: 840470 LAKE BALLINGER 23931 HIGHWAY 99 EDMONDS, WA 98026 REVI DATE A 1 7/16/21 0 1 1 /27/22 DESCRIPTION PRELIMS FOR CONSTRUCTION W7T" - 01 /27/2022 UBI NUMBER: 604-106-184 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED: JLB DRAWN: JLB CHECKED: PWM JOB #: 21 CCA06M-0080 CELL REFERENCE GROUND BAR T T GROUNDING � T SCHEMATIC GROUNDING SCHEMATIC Gml TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR O jo O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O- O, O O O O O O O O O O O O O O O @ 0 0 0 00000000000000000 TWO HOLE LONG BARREL COMPRESSION LUG (TYP) NOTES: 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL. ANTENNA GROUND BAR DETAIL SCALE: NOT TO SCALE #6 MIN. FROM ANTENNA CABLE GROUND KIT 77:�,,, GROUND BAR ON SHELTER. ICE BRIDGE, OR ON ANTENNA TOWER °lo TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING GROUNDWIRE INSTALLATION GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER 010 TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR O J0 0 0 0 0 0 0 0 0 0 0 0 0 0 0,, O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O ,O TWO HOLE LONG BARREL COMPRESSION LUG (TYP) #2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER GROUND RING (2 TYP. FOR BOTTOM GROUND BAR ONLY) NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. TOWER/SHELTER GROUND BAR DETAIL SCALE: NOT TO SCALE WIRE SIZE BURNDY LUG BOLT SIZE #6 GREEN INSULATED YA6C-2TC38 3/8" - 16 NC SS 2 BOLT #2 SOLID TINNED YA3C-2TC38 3/8" - 16 NC SS 2 BOLT #2 STRANDED YA2C-2TC38 3/8" - 16 NC SS 2 BOLT #2/0 STRANDED YA26-2TC38 3/8" - 16 NC SS 2 BOLT #4/0 STRANDED YA28-2N 1/2" - 16 NC SS 2 BOLT BURNDY GROUND LUG W/ LONG BARREL (SEE CHART) NUT (TYP) LOCK WASHER (TYP) HEAT SHRINK (CLEAR) GROUND FR CONDUCTOR GROUND BAR BOLT (SEE CHART) BURNDY TWO HOLE LUG W/ (TYP) LONG BARREL (SEE CHART) BARE WIRE TO BE TREATED WITH NO-OX AT BOTH ENDS NOTE: AT&T QJ4CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 D 0 O P. MARSHALL &ASSOCIATES STRANDED ALL GROUNDING LUGS ARE TO BE (SEE CHART) INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALL HARDWARE BOLTS, 3/8-11x1" TAMPER NUTS, LOCK WASHERS SHALL BE STAINLESS RESISTANT BOLT STEEL. ALL HARDWARE ARE TO BE AS (TYP) FOLLOWS: BOLT, FLAT WASHER, GROUND WA6358 BAR, GROUND LUG, FLAT WASHER AND INSULATORS NUT. SEE NOTE 2. (TYP) T BU #: 840470 ® WALL BRACKET 0 MECHANICAL LUG CONNECTION LAKE BALLINGER (TYP) 0 0 3 Y� ® 0 SCALE: NOT TO SCALE 23931 HIGHWAY 99 ® 0 � EDMONDS, WA 98026 ® UNIVERSAL COPPER 0 GROUND BAR (4" x20") STAINLESS STEEL BOLT LOCK WASHER � (TYP)P/N M 10 (TYP) STAINLESS STEEL REV DATE DESCRIPTION TWO -HOLE FLAT WASHER A 7/16/21 PRELIMS COMPRESSION LUG 2-HOLE CRIMP/ (TYP) COMPRESSION CONNECTOR T I 0 1/27/22 FOR CONSTRUCTION 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. GROUND BAR DETAIL SCALE: NOT TO SCALE �JSCALE: NOT TO SCALE GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL (TYP) BELLVILLE WASHER STAINLESS STEEL NUT (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS DRAGC STAINLESS STEEL BOLT STAINLESS STEEL RECEIVED FLAT WASHER 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT STEEL 2-HOLE CRIMP/ J COMPRESSION STAINLESS STEEL N o WEATHERPROOFING KIT CONNECTOR FLAT WASHER (TYPICALLY) 12" TO 24" (SEE NOTE 3) (TYP) ANTENNA CABLE 120" MAX. COAX JUMPER NOTE: MINIMUM OF S/S NUT STAINLESS STEEL STAINLESS STEEL NUT (TYP) 3 THREADS TO BE (TYP) BELLVILLE WASHER DESIGNED: JLB VISIBLE (TYP) wipj� TO ANTENNA TYP (TYP) SINGLE CONNECTOR AT STEEL OBJECTS ° w DRAWN: JLB S/S SPLIT WASHER CHECKED: PWM CABLE 2 HOLE LONG BARREL TINNED (nP ) STAINLESS STEEL CONNECTOR SOLID COPPER SELF -DRILLING STAINLESS STEEL "d �p J3949" WEATHERPROOFING KIT LUG S/S FLAT METAL SCREW FLAT WASHER '�s G `SjpNAL JOB #: #6 STRANDED COPPER GROUND (SEE NOTE 3) (TYP) WASHER (TYP) (TYP) (TYP) 01/27/2022 21 CCA06M-0080 WIRE UBI NUMBER: 604-106-184 (GROUND TO GROUND BAR) SEE CABLE GROUND KIT 2-HOLE CRIMP/ NOTES 1 & 2 COMPRESSION TIN COATED SOLID CONNECTOR COPPER BUS BAR S/S FLAT NOTES: WASHER DRAGON TOOTH WASHER:_GROUNDING METALLIC OBJECT (TYP) 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO CHERRY INSULATOR GROUND BAR. INSTALLED IF REQUIRED BOLT SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS DETAILS 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE (nP) (TYP) MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION SCALE: NOT TO SCALE LUG DETAIL SCALE: NOT TO SCALE HARDWARE DETAIL FOR EXTERIOR CONNECTIONS SCALE: NOT TO SCALE Gm2 Ant Pos 1 NNHH-65C-R4 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x REF 1 2 3 4 5 6 7 8 AirScale RRH 4T4R B5 160WAHCA (850 ) LTE 5G D C6-48-60-18-8F (Site Squid) Fi be r Tru nk RRH4x25-WCS-4R (WCS) LTE _ 5G DC Demarcation Power Plant Sector A Ant Pos 2 N N H4-65C-R6 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x REF 1 2 3 4 5 6 7 8 9 10 11 12 AirScale Dual RRH 4T4R AirScale Dual RRH 4T4R B12/14320W AHLBA B25/66320W AHFIB (700) (190 0/210 0) LTE 5G LTE 5G D C6-48-60-18-8F (Site Squid) I Hatch Plate Baseband Unit 5G Ant Pos 4 DC9-48-60-24-8C-EV (Site Squid) I RECEIVED 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT •10 VITIA1• i • • . Sector B Ant Pos 1 Ant Pos 2 Ant Pos 4 AEQK NNH4-65C-R6 NNHH-65C-R4 xxxxxxxx xxxxxxxx x x x x x x x x xxxxxxxx x x x x x x x x x x x x xxxxxxxx x x x x x x x x x x x x x x x x x x x x xxxxxxxx x x x x x x x x x x x x x x x x x x x x xxxxxxxx x x x x x x x x xxxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x RET REf RET 17 2 3 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 L L- AirScale Dual RRH 4T4R AirScale Dual RRH 4T4R AirScale RRH 4T4R B5 B12/14320W AHLBA B25/66320W AHFIB 160WAHCA RRH4x25-WCS-4R (700) (190 0/210 0) (850) (WCS ) LTE 5G LTE 5G LTE 5G LTE 5G M DC9-48-60-24-8C-EV DC6-48-60-18-8F DC6-48-60-18-8F (Site Squid) (Site Squid) (Site Squid) RECEIVED 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Hatch Plate DC Demarcation Fi be r Tru nk Fi be r Tru nk Baseband Unit Baseban d Unit Power Plant 5G LTE IWAIj Sector C Ant Pos 1 Ant Pos 2 Ant Pos 4 NNHH-65C-R4 AEQK NNH4-65C-R6 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x RET 1 2 3 4 5 6 7 8 REF 1 2 1 2 3 4 RET 5 6 7 8 9 10 11 12 AirScale RRH 4T4R B5 160WAHCA RRH4x25-WCS-4R (WCS) AirScale Dual RRH 4T4R AirScale Dual RRH 4T4R B12/14320W AHLBA B25/66320W AHFIB (850) LTE 5G LTE 5G (700) LTE (190 0/210 0) 5G LTE 5G 1 DC6-48-60-18-8F DC9-48-60-24-8C-EV DC6-48-60-18-8F (Site Squid) (Site Squid) (Site Squid) RECEIVED 2/10/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Hatch Plate - - DC Demarcation Fi be r Tru nk Fi be r Tru nk Baseband Unit FL Baseband Unit Power Plant LT E 5G