Loading...
REVIEWED BLD BLD2022-0048+Calculations+1.17.2022_9.45.59_AM+2623863ALBERT H. COHEN DESIGN COMPANY, P.S. 330 Dayton Street Suite 6 Edmonds, Washington 98020 425-776-7373 RECEIVED Jan 17 2022 BLD2022-0048 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAVITY LOAD DESIGN ANALYSIS FOR Wright Residence 18911 - 94" Ave West Edmonds, WA 98020 DESIGN LOADS Roof Live 25 PSF (SNOW), Dead 13 PSF, Total 38 PSF Floor Live 40 PSF, Dead 10 PSF, Total 50 PSF Sleeping Areas Live 30 PSF, Dead 10 PSF, Total 40 PSF Deck and Balcony Live 60 PSF, Dead 10 PSF, Total 70 PSF 5496 REGISTERED ARCHITECT ALBERT H. COHEN STATE OF WASHINGTON PREPARED 1 / 16/2022 Albert H Cohen Design Company 330 Dayton St Suite 6 Edmonds WA 98020 425-776-7373 BeamChek v2021 licensed to: Albert H Cohen Reg # 8080-69302 Wright Resiidence Typical Deck Beam Beam A Prepared by: AHC Date: 1/16/22 Selection PT 6x 12 HF #1 Lu = 0.0 Ft Conditions NDS 2018, Wet Use, Incised Min Bearing Area R1= 9.8 in R2= 9.8 in (2.0) DL Defl= 0.05 in Data Attributes Actual Critical Status Ratio Values Adiustments Loads Beam Span 10.5 ft Reaction 1 LL 2205 # Reaction 2 LL 2205 # Beam Wt per ft 15.37 # Reaction 1 TL 2653 # Reaction 2 TL 2653 # Bm Wt Included 161 # Maximum V 2653 # Max Moment 6965 '# Max V (Reduced) 2169 # TL Max Defl L / 240 TL Actual Defl L / 672 LL Max Defl L / 360 LL Actual Defl L / 946 Section (in') Shear (in2) TL Defl (in) LL DO 121.23 63.25 0.19 0.13 99.49 29.05 0.53 0.35 OK OK OK OK 82% 46% 36% 38% Fb (psi) Fv (psi) E(psi x mil) Fc (psi) Reference Values 1050 140 1.3 405 Adjusted Values 840 112 1.2 271 CIF Size Factor 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet+Ci Incised 0.80 0.80 0.95 0.67 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 420 Uniform TL: 490 = A Uniform Load A 0 R1 = 2653 R2 = 2653 SPAN =10.5FT Uniform and partial uniform loads are Ibs per lineal ft.