Loading...
APPPROVED BLD BLD2022-0417+Architectural & SITE _Plan+3.30.2022_3.49.14_PM+2771742TENANT REVISIONS TO EXISTING FIRST FINANCIAL NORTHWEST BANK Approved by Fire 04/07/2022 AFM l</_Fl tterer GENERAL NOTES A. GENERAL REQUIREMENTS 1. WHERE THEY OCCUR IN THIS PROJECT, ADHERENCE WITH THESE NOTES IS REQUIRED. ADDITIONAL NOTES ARE PROVIDED ON EACH CONSTRUCTION SHEET. B. CODES 1. THE INTERNATIONAL BUILDING CODE AND ALL OTHER APPLICABLE CODES HAVING JURISDICTION OVER THIS PROJECT. THE DESIGN AND CONSTRUCTION SHALL ADHERE TO THESE APPLICABLE CODES. IF ANY INSTANCES IN WHICH THE METHODS OR STANDARDS OF INSTALLATION CONFLICT, OR DO NOT MEET OR EXCEED CODE REQUIREMENTS, NOTIFY THE DESIGNER. C. DRAWINGS AND SPECIFICATIONS 1. STRUCTURAL, CIVIL, PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS ARE ALL SUPPLEMENTARY TO THE A -SHEETS. CONTRACTORS SHALL VERIFY NO CONFLICTS EXIST BETWEEN SUPPLEMENTAL DRAWINGS AND THE A -SHEETS. NOTIFY THE DESIGNER IF ANY CONFLICTS ARISE. 2. DOORS, WINDOWS, AND OTHER OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE LOCATED 4" FROM THE ADJACENT WALL. D. DIMENSIONS 1. IF ANY CONDITIONS EXIST THAT ARE INCONSISTENT WITH THE DRAWINGS, NOTIFY THE DESIGNER. 2. DO NOT SCALE DRAWINGS. NOTIFY DESIGNER OF ANY DISCREMPANCIES BETWEEN DIMENSIONS PROVIDED AND FIELD -MEASURED DIMENSIONS. 3. DIMENSIONS ARE TO THE FACE OF FINISHED SURFACE, UNLESS CLEARLY SHOWN OTHERWISE, OR NOTED OTHERWISE. E. COORDINATION 1. EACH CONTRACTOR SHALL VERIFY AND COORDINATE WORK WITH OTHER TRADES. F. EXITS 1. ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE NEED OF A KEY OF ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED. 2. ALL THRESHOLDS SHALL BE A MAXIMUM OF Y2" IN ELEVATION CHANGE. 3. ALL EXIT SIGNS SHALL HAVE LETTERS 6 INCHES HIGH (MINIMUM), AND SHALL ADHERE TO ALL APPLICABLE CODES. G. GENERAL CONSTRUCTION 1. THE CONTRACTOR SHALL EXAMINE EXISTING CONDITIONS AND VERIFY SIZE AND LOCATION OF ALL MECHANICAL AND ELECTRICAL ELEMENTS. CONTRACTOR SHALL VERIFY ALL REQUIRED CLEARANCES AND INSTALL ALL ELEMENTS PER MANUFACTURER'S INSTRUCTIONS, 2. ALL WOOD MATERIALS, INCLUDING FRAMING LUMBER, PLYWOOD AND CONCEALED WOOD, SHALL BE FIRE RETARDANT TREATED. 3. ALL EXTERIOR WALL OPENINGS, AND ACCOMPANYING ELEMENTS, INCLUDING FLASHING, COUNTER FLASHING AND EXPANSION JOINTS, SHALL BE CONSTRUCTED TO BE WEATHERPROOF H. FIRE PROTECTION 1. FIRE EXTINGUISHERS SHALL BE PROVIDED AND INSTALLED. LOCATION, INSTALLATION, AND NUMBER OF EXTINGUISHERS SHALL BE CONFIRMED BY FIRE CODE OFFICIALS. 2. REQUIRED FIRE ALARM DEVICES SHALL BE PROVIDED, AND COORDINATED WITH THE DESIGNER. SHOP DRAWINGS FOR SUCH SYSTEMS SHALL BE PROVIDED BY THE CONTRACTOR. I. GLAZING 1. THIS PROJECT CONTAINS GLAZING THAT IS SUBJECT TO FEDERAL GLAZING STANDARDS, IN ADDITION TO ALL CODE REQUIREMENTS. GLAZING SUBCONTRACTOR SHALL VERIFY CONFORMANCE TO SUCH CODES AND REQUIREMENTS. 2. ALL GLAZING AT DOORS AND RELITES SHALL BE TEMPERED SAFETY GLAZING. J. FINISHES 1. THERE SHALL BE NO UNFINISHED MATERIALS OR EXPOSED PLUMBING, MECHANICAL, OR ELECTRICAL ELEMENTS, UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. 2. OFFSET FRAMING STUDS WHERE REQUIRED IN ORDER TO MAINTAIN FLUSH FINISHED SURFACE. 3. ALL FINISHED MATERIALS MUST COMPLY WITH THE FLAME SPREAD CLASS AS IDENTIFIED IN IBC 2018 TABLE 803.9 K. PLUMBING/ELECTRICAL/MECHANICAL 1. CONTRACTOR SHALL COORDINATE ALL NEW PLUMBING, ELECTRICAL, MECHANICAL, ETC. ELEMENTS WITH EXISTING ELEMENTS AND VERIFY SUCH NEW ELEMENTS ARE INSTALLED PER ALL APPLICABLE CODES AND REGULATIONS. 2. ALL PLUMBING PIPES IN WALLS SHALL HAVE ACOUSTICAL INSULATION. 3. VERIFY THE LOCATION AND INSTALLATION OF ALL PLUMBING, ELECTRICAL, MECHANICAL, ETC. ELEMENTS WITH OTHER TRADES AND OWNER -SUPPLIED ELEMENTS BEFORE INSTALLATION. L. ACCESSIBILITY SIGNAGE 1. ALL SIGNAGE SHALL COMPLY WITH ICC/ANSI 117.1, M. WASHINGTON STATE ENERGY CODE - CHAPTER 5 - EXISTING BUILDINGS 1. SECTION C503 - ALTERATIONS a. C503.1 - GENERAL: ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE CODE FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS CONFORMING WITH THE PROVISIONS OF THIS CODE THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION. b. C503.3 - BUILDING ENVELOPE: NEW BUILDING ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTIONS C402.1 THROUGH C402.5 AS APPLICABLE c. C503.4 - MECHANICAL SYSTEMS:THOSE PARTS OF SYSTEMS WHICH ARE ALTERED OR REPLACED SHALL COMPLY WITH SECTION C403. ADDITIONS OR ALTERATIONS SHALL NOT BE MADE TO AN EXISTING SYSTEM THAT WILL CAUSE THE EXISTING SYSTEM TO BECOME OUT OF COMPLIANCE d. C503.6 - LIGHTING AND MOTORS: ALTERATIONS THAT REPLACE 50% OR MORE OF THE LUMINAIRES IN A SPACE ENCLOSED BY WALLS OR CEILING -HEIGHT PARTITIONS, OR REPLACE 50% OR MORE OF THE TOTAL INSTALLED WATTAGE OF EXTERIOR LUMINAIRES SHALL COMPLY WITH SECTIONS C405.4 AND C405.5. WHERE LESS THAN 50% OF THE FIXTURES IN AN INTERIOR SPACE ENCLOSED BY WALLS OR CEILING -HEIGHT PARTITIONS IS ALTERED, THE INSTALLED LIGHTING WATTAGE SHALL BE MAINTAINED OR REDUCED. 2. SECTION C505 - CHANGE OF OCCUPANCY OR USE a. WHERE THE USE IN A SPACE CHANGES, BASED ON TABLES C405.4.2(l) OR (2), THE INSTALLED LIGHTING WATTAGE SHALL COMPLY WITH SECTION C405.4. VICINITY MAP EDMONDS BRANCH SALISH CROSSING, EDMONDS, WA ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE HIGHLAND DEVELOPMENT PETER C. STRICKER ARCHITECT 5415 SEWARD PARK AVE. S. SEATTLE, WA stricker7@icloud.com NO. DESCRIPTION DATE PROJECT INFORMATION PROJECT TEAM LIST OF DRAWINGS PCS REVIEW 2-28-22 PROJECT SCOPE: INSTALL NEW INTERIOR WALL (NON-STRUCTURAL) & INSTALL SECOND OWNER/REP: FORT WAYNE LIMA ROAD ASSOCIATES LLC/ Al COVER SHEET PERMIT SET 3-24-22 ENTRY DOOR INTO ATM SPACE POPEYES TEXAS PARTNERS LLC / EDMONDS RETAIL LLC A2 DEMOLITION PLAN, FLOOR PLAN & ADDRESS: 184 SUNSET AVENUE 940 EMMET AVE., SUITE 200 WALL ELEVATIONS EDMONDS, WA 98020 BELMONT, CA 94002 A3 DETAILS PARCEL NUMBER: 27032300104500-0188607 TENANT: FIRST FINANCIAL NORTHWEST BANK 201 WELLS AVENUE S. TYPE OF CONSTRUCTION: V-B RENTON, WA 98057 PHONE: 425-255-4400 BUILDING AREA: 21,056 SF FAX: 425-228-7227 TENANT AREA: 2,881 SF CONTRACTOR: HIGHLAND DEVELOPMENT APPi,.OVED 24376 FJORD PLACE AREA OF WORK, THIS PERMIT ±237 SF POULSBO, WA 98370 PHONE: 360-271-5870 w v z STORY: GROUND LEVEL FAX: 360-779-4993 CD LU OCCUPANCY: B - BUSINESS ARCHITECT: PETER STRICKER ANS MUST E CD (NO OCCUPANCY CHANGE PROPOSED) 5415 SEWARD PARK AVENUE SEATTLE, WA 98118 SPRINKLERS: YES, EXISTING PHONE: 206-999-7731 EMAIL: stricker7@icloud.com CODE USED: 2018 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS, ON JO 'T E 2018 WASHINGTON STATE ENERGY CODE � 1 I � 1 City Of Edmonds Building Department Work REMODEL ----------------------------------------------- Address 184 SUSNET AVE S --------------------- ------------------------- ---- Owner FIRST FINANIAL BANK --------- ------------------------- ----------------- Approved Date 04/05/2022 Building Official . Eris. C 4-ter Permit Number BLD2022-0417 W W V J L.L W O cD U z_ Q 2 I- O V Z z T i U) m i iY L U (? 0 Z W J U) U) Q Owco 0 C) U QO Cn W Z Q U) F-MM LLJ 0 Z J Q co z 0 LLJ LL VJ^ CO Z Itim z Cn 00 Lu Lvu LL RECEIVED 0 Apr 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FLOOR PLAN LEGEND DEMOLITION PLAN LEGEND EXISTING STOREFRONT AND DOORS TO REMAIN 0 EXISTING WALL ® NEW WALL, AS NOTED AS -BUILT DIMENSION, PROVIDED FOR (VERIFY) —'� REFERENCE ONLY. VERIFY DIMENSION IN FIELD GENERAL NOTES 1. WALL DIMENSIONS ARE TO FACE OF STUD, TYP., 8. THERE SHALL BE NO UNFINISHED MATERIALS OR U.N.O. EXPOSED PLUMBING, MECHANICAL, OR ELECTRICAL ELEMENTS, UNLESS SPECIFICALLY NOTED 2. ALL DOORS ARE 3'-0" WIDE, TYP., U.N.O. OTHERWISE ON THE PLANS. 3. ROUGH OPENING OF DOOR IS LOCATED 4" FROM 9. OFFSET FRAMING STUDS WHERE REQUIRED IN ADJACENT WALL, TYP., U.N.O. ORDER TO MAINTAIN FLUSH FINISHED SURFACE. 4. ALL EXITS SHALL BE OPERABLE FROM THE INSIDE 10. ALL FINISHED MATERIALS MUST COMPLY WITH WITHOUT THE NEED OF A KEY OF ANY SPECIAL THE FLAME SPREAD CLASS AS IDENTIFIED IN IBC 2018 KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED TABLE 803.9. WITH PANIC HARDWARE WHERE REQUIRED. 11. ALL DOOR HANDLES FOR NEW DOORS, OR DOORS 5. THE CONTRACTOR SHALL EXAMINE EXISTING WHERE NEW HARDWARE IS TO BE INSTALLED SHALL CONDITIONS AND VERIFY SIZE AND LOCATION OF ALL BE LEVER -STYLE. MECHANICAL AND ELECTRICAL ELEMENTS. CONTRACTOR SHALL VERIFY ALL REQUIRED 12. NOT LESS THAN 5% OF THE PERMANENTLY CLEARANCES AND INSTALL ALL ELEMENTS PER INSTALLED WORK SURFACES SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS, IBC 2018 SECTION 1109.11 6. ALL WOOD MATERIALS, INCLUDING FRAMING 13. ALL GLAZING AT DOORS AND RELITES SHALL BE LUMBER, PLYWOOD AND CONCEALED WOOD, SHALL TEMPERED SAFETY GLAZING. BE FIRE RETARDANT TREATED. 7. ALL EXTERIOR WALL OPENINGS, AND ACCOMPANYING ELEMENTS, INCLUDING FLASHING, COUNTER FLASHING AND EXPANSION JOINTS, SHALL BE CONSTRUCTED TO BE WEATHERPROOF I-------------------------------------------------------------------I New Glazing shall comply with the; prescriptive requirements of the I I Washington State Energy Code -------------------------------------------------------------------- FIELD VERIFY ^' EQ. T-0" EQ. DOOR NOTE: COORDINATE FINAL DESIGN WITH PROPERTY OWNER AND TENANT. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS 0 0 tl STOREFRONT ELEVATION 1/4" = 1'-01, 14 A3 ALUMINUM FRAMED GLASS DOOR/WINDOW SYSTEM PER MANUFACTURER 5 A3 EQ. EQ. T-0" EQ. EQ. DOOR 9 7 A3 A3 6 A3 /' SG SG SG SG SG 10 �\ A3 PER PLAN WALL ELEVATION 1/4" = V-0" 0 SG SAFETY GLAZING NOTE: ALL RELITES AND INTERIOR DOORS TO BE SAFETY GLAZING 1010.1.9.4 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 1. Places of detention or restraint. 2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side, provided: 2.1. The locking device is readily distinguishable as locked; 2.2. A readily visible and durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background; and 2.3. The use of the key -operated locking device is revocable by the building official for due cause. 3. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts has no doorknob or surface -mounted hardware. 1013.4 Raised character and braille exit signs. A sign stat- ing EXIT in visual characters, raised characters and braille and complying with [CC A117.1 shall be provided adjacent to each door to an area of refuge, providing direct access to a stairway, an exterior area for assisted rescue, an exit stairway or ramp, an exit passageway and the exit discharge. IT SE BLDG C ELEC. (NO WORK STOR. VAULT I I)rH001 HOTELING NO CHANGES TO EXISTING RESTROOMS STORAGE ROOM, IT CLOSET & VAULT NO CHANGES ❑I HOTELING BREAK I NO CHANGES LL I ROOM NO CHANGES HOTELING HOTELING NO CHANGES NO CHANGES HOTELING NO CHANGES COMMUNITY --- ROOM NO CHANGES \`---------i----' LOBBY NO CHANGES 1 7 HOTELING NO CHANGES ALIGN NEW WALL WITH EXISTING WALL AS SHOWN .----------- -- ------------------ NEW.WINDOWS ANp 3-0 WIDE DOOR `> WAITING: 2 A � A2 ' I N JATM STOREFRONtANG +I BBY 2 DOORS TO REMAIN -, EXISTING ATM TO REMAIN i � q2 NEW STOREFRONT -------------------------------------- AND 3-0 WIDE DOOR AREA OF WORK „ FLOOR PLAN 1 /8" = 1'-01, ELEMENT TO BE REMOVED, AS NOTED GENERAL NOTES 1. PATCH OR REPAIR ALL ADJACENT SURFACES (FLOORS, WALLS, CEILINGS) AS NEEDED TO RECEIVE NEW FINISH. 2. HAZARDOUS MATERIALS ARE NOT EXPECTED TO BE ENCOUNTERED IN THE SCOPE OF WORK. IF SUCH MATERIALS ARE ENCOUNTERED, IMMEDIATELY NOTIFY THE DESIGNER AND TENANT. 3. ENSURE ALL WALLS, GLAZING, FLOORING, ETC. THAT WILL REMAIN HAVE ADEQUATE PROTECTION DURING DEMOLITION. 4. COORDINATE EXTENT OF DEMOLITION WITH NEW CONSTRUCTION. 5. REMOVE ALL EXISTING BASEBOARD, MOLDING, TRIM, ETC. UNLESS NOTED OTHERWISE. VERIFY WITH CLIENT. 6. ADDITIONAL DEMOLITION MAY BE REQUIRED. CONSULT ALL TRADES TO DETERMINE EXTENT OF DEMOLITION THAT IS REQUIRED. IT BLDG C SE ELEC. (NO WORK STOR. VAULT -7=� I I�\ — NO CHANGES TO I J 1 EXISTING �\=-1 QRESTROOMS STORAGE RO M, IT HOTELING CLOSET & VAULT NO CHANGES i i BREAK a- ROOM ��� NO CHANGES HOTELING NO CHANGES HOTELING NO CHANGES LOBBY NO CHANGES HOTELING NO CHANGES HOTELING NO CHANGES COMMUNITY ROOM NO CHANGES HOTELING NO CHANGES REMOVE EXISTING SECURITY GATE ----NY\ WAITING : AAREA LO REMOVE STOREFRONT ; i ---------------------------------- AREA OF WORK „ DEMOLITION PLAN 1 /8" = 1'-01, EXISTING ATM TO REMAIN HIGHLAND DEVELOPMENT PETER C. STRICKER ARCHITECT 5415 SEWARD PARK AVE. S. SEATTLE, WA stricker7@icloud.com NO.I DESCRIPTION DATE V Z_ Q 0 w w _ Cn C� Z_ Cn X W O I- U) Z O NLIJ Z Q LLI PCS REVIEW 2-28-22 PERMIT SET 3-24-22 0� co OZ 00 J � LL Q Z w a� aw Z J O< J oZj OZ W J 0 0- 0 co ZT Q i m iY CD (? Z - LJ< J O Lu U) Q U o<Z Z =[ Cn ---� LLI Q Z Q Z W U_ U VJ 00 L.L � LJL RECEIVED Apr 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A2 SOUND BATTS (AS REQUIRED) 2%2"x12" METAL STUD BLOCKING AS REQUIRED FOR BRACING H I G H LAN D WALL BRACING. MAXIMUM UNBRACED LENGTH OF 8'-0". ATTACH STUD TO TOP OF RUNNER WITH A DEVELOPMENT MINIMUM OF (4) 7x16 STEELER 023 ASTM A-466 MAIN OR CROSS TEE SCREWS AS REQUIRED MAIN OR CROSS BRACE TEE TOP RUNNER, EXPOSED EDGES ACOUSTICAL SEALANT (TYP.) --_ TOP RUNNER, EXPOSED EDGES PETER C. STRICKER NOTE: ENTIRE ACOUSTIC CEILING GWB CEILING TAPED CEILING, PER PLAN ARCHITECT TILE (A.C.T.) CEILING SYSTEM AND SANDED OVER 6" � SHALL BE INSTALLED PER IBC �_ METAL CEILING JOISTS 5415 SEWARD PARK AVE. S. 2018 SECTIONS 808.1 & 1613.1 3�4„ @ 12" O.C., SEE PLANS FOR CEILING HEIGHT SEATTLE, WA stricker7@icloud.com SHIM (AS REQUIRED) METAL HEAD, PER N0. DESCRIPTION DATE MANUFACTURER METAL STUD NOTE: ENTIRE ACOUSTIC CEILING PCS REVIEW 2-28-22 SOUND SEALANT,PER NOTE: ENTIRE ACOUSTIC CEILING TILE (A.C.T.) CEILING SYSTEM SUSPENDED A.C.T. WALL, TYP. MANUFACTURER TILE (A.C.T.) CEILING SYSTEM SHALL BE INSTALLED PER IBC WITH 24"x48" PANELS, SHALL BE INSTALLED PER IBC 2018 2018 SECTIONS 808.1 & 1613.1 SEE PLAN FOR q FULL HEIGHT TEMPERED SECTIONS 808.1 & 1613.1 PERMIT SET 3-24-22 HEIGHT GLAZING, PER MANUFACTURER @WALL-ULILING DETAIL q HEAD DETAIL CEILING -BRACING DETAIL WALL -CEILING DETAIL 3" = 1'-0" " 3" = 1'-0" 3" = 1'-0" 1 3" = 1'-0„ qu FULL HEIGHT TEMPERED GLAZING, PER MANUFACTURER DOOR FRAME WITH APPLIED STOP z SOUND SEALANT, PER SHIM (AS REQUIRED) MANUFACTURER ¢ �' Ld Ll DOOR PER PLAN METAL SILL, PER MANUFACTURER BASEBOARD , rn �¢ tr cn POWER DRIVEN FASTENER 24" %2 � O.C., EMBED 1" NEW FLOOR FINISH, PER FULL HEIGHT TEMPERED a SHIM (AS REQUIRED) CLIENT GLAZING, PER MANUFACTURER ❑ PATCH AND REPAIR AS SILICON RUBBER SEAL a REQUIRED METAL JAMB, PER MANUFACTURER TEMPERED GLASS RELITE, SIZE PER PLANS DETAIL SILL DETAIL RELITE-DOOR JAMB DETAIL WALL -BASE DETAIL (4)JAMB 3" = 1'-01, 1 O 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" v 24"x48" A.C.T. Q W MAIN Q RUNNER METAL STUD WALL, TYP. /�22" 4 #12 GAUGE WIRE SEISMIC >00< LEE METAL STUD WALL, TYP. TYP. BRACE PER ASTM C 635 AND METAL STUD FURRING >00< ASTM C 636 z KINX CEILING, PER PLAN C-CHANNEL, OR SIMILIAR METAL FRAME EXTERIOR WALL _ STRUCTURAL FRAMING (EXISTING) MULLION (EXISTING) DOOR SILENCERS 45 A.C.T. DOOR PER PLAN NOTE: ENTIRE ACOUSTIC CEILING CONTINUOUS BEAD >001 OF SEALANT AT 4'-0" MIN. TILE (A.C.T.) CEILING SYSTEM SHALL BE INSTALLED PER IBC STOREFRONT NOTE: SEISMIC SEPARATION JOINTS NOT REQUIRED 2018 SECTIONS 808.1 & 1613.1 FOR CEILINGS UNDER 2500 SQUARE FEET IN AREA METAL FRAME TO MATCH VVA LLEXISTING AT MU.LLl0N.DETAl.L DOOR HEAD DETAIL CEILING DETAIL (D 7 ` _ WALL U) W LY WALL AT STOREFRONT w (D 15 3" - 1'-01, SEISMIC NOTE: TIE TOGETHER ENDS OF O Z z W Q STRUT TYP. MAIN RUNNERS AND CROSS J MEMBERS TO PREVENT \v SEPARATING. O w u) G.W.B. BOTH SIDES 24"x48" ACOUSTICAL r , U > 0 O CEILING TILE (A.C.T.), TYP. — `C) Q 3%2" METAL STUDS Z = OC AT 24" O.C. w G NOTE: ALL CROSS MEMBERS AND XJ w 7� J U) 0 X MAIN RUNNERS ARE TO BE �/ Z z LLJ < INDEPENDENTLY SUPPORTED A o MAXIMUM OF 8" FROM ENDS. U D SEISMIC BRACE PER ASTM z C 635 AND ASTM C 636 z Cn 00 NOTE: SECURE ENDS OF MAIN w RUNNERS AND CROSS MEMBERS U TO WALL CHANNELS ON TWO RECEIVED SOUND BATTS WALLS ONLY. THE OTHER ENDS w (AS REQUIRED) MUST REMAIN FREE (WITH Apr 01 2022 CLEARANCE) AND MUST BE ITY FO SUPPORTED AT ENDS FROM DEVELOPMENT SERVICES T-- YP . PARTITION WALL STRUCTURE ABOVE. DEPARTMENT 8 3" = 1'-0" NOTE: ENTIRE ACOUSTIC CEILING TILE (A.C.T.) CEILING SYSTEM SHALL BE INSTALLED PER IBC 2018 SECTIONS 808.1 & 1613.1 12'-0" MAX. 6'-0" MAX. CEILING DETAIL A3 w = 14 w-0" 3" ' U)