REVIEWED BLD-RESUB1 BLD2022-0639+Calculations+7.1.2022_3.12.30_PM+2967673BLD2022-0639 RES U 6 Jul 01 2022 BeamChek v2021 licensed to: Daniel C Smith PE Consulting Engineers Reg # 4009-67603 CITY OF EDMONDS DEVELOPMENT SERVICES 9509 232nd St SW Flush Beam Calc DEPARTMENT Date: 6/30/22 ............................................... REVIEWED Selection (2) 2x 10 DF North #2 Lu = 0.0 Ft BY CITY OF EDMONDS Conditions NDS 2018, Wet Use BUILD - Min Bearing Area R1= 3.0 W R2= 3.0 in2 (2.0) DL DO= 0.02 in Data Attributes Actual Critical Status Ratio Values Adiustments Loads Beam Span 7.0 It Reaction 1 LL 1050 # Reaction 2 LL 1050 # Beam Wt per ft 6.74 # Reaction 1 TL 1249 # Reaction 2 TL 1249 # Bm Wt Included 47 # Maximum V 1249 # Max Moment 2185'# Max V (Reduced) 974 # TL Max DO L 1240 TLActual Deft L t >1000 LL Max Deft L 1360 LL Actual Deft L / > 1000 Section (W) Shear (in') TL DO (in) LL DO 42.78 27.75 0.08 0.06 28.04 8.36 0.35 0.23 OK OK OK OK 66% 30% 22% 24% Fb(psi) Fv(psi) E(psi x mil Fc I(psi) Reference Values 850 180 1.6 625 Adjusted Values 935 175 1.4 419 CF Size Factor 1.100 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress NIA Cm Wet Use 1.00 0.97 0.90 0.67 Ci Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 300 Uniform TL: 350 = A F- Uniform Load A 0 Z\ R1 = 1249 R2 = 1249 SPAN =7FT Uniform and partial uniform loads are Ibs per lineal ft. 44613