Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2022-0062+Fire_Sprinkler_Equipment_Specification_Sheets+6.15.2022_3.16.34_PM+2934767
I CONSTRUCTION, INC 7855 South 206t" Street, Kent, WA 98032 • Phone: 253-872-7222 •Fax: 253-872-7277 FIRE SPRINKLER EQUIPMENT SUBMITTAL RANCH 99 TI 22511 HWY 99 EDMONDS, WA 98026 Archer Job # S22-040 TABLE OF CONTENTS Pipe and Fittings • Schedule 10 & Schedule 40 — Bull Moose • Ductile Iron Threaded Fittings — Anvil • Mechanical Tees — Victaulic Hangers and Sway Bracing • Hanger Ring — Erico Model 115 • SBC Stamped Beam Clamp — Erico • Retainer Strap — Erico Model 300C Fire Sprinklers • Pendent, QR — Victaulic Model V2708 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pipe Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot -dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. 1 1.315 1.097 1.41 Ibs/ft 91 1 1 /4 1.660 1.442 1.81 Ibs/ft 61 1 1 /2 1.900 1.682 2.09 Ibs/ft 61 2 2.375 2.157 2.64 Ibs/ft 37 2 1 /2 2.875 2.635 3.53 Ibs/ft 30 3 3.500 3.260 4.34 Ibs/ft 19 4 4.500 4.260 5.62 Ibs/ft 19 Schedule 40 Pipe 1 1.315 1.049 1.68 Ibs/ft 70 1 1 /4 1.660 1.380 2.27 Ibs/ft 51 1 1 /2 1.900 1.610 2.72 Ibs/ft 44 2 2.375 2.067 3.66 Ibs/ft 30 2 1 /2 2.875 2.468 5.80 Ibs/ft 30 3 3.500 3.068 7.58 Ibs/ft 19 4 4.500 4.026 10.80 Ibs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak -tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, A` Chesterfield, MO 63017 contact your salesperson e . L us La® (800) 325-4467 today at (800) 325-4467 or LISTEDII BULL MOOSE TUBE COMPANY FAX: (636) 537-2645 (636) 537-2600 in the USA, www.bullmoosetube.com or from Canada F M A CR H O company e-mail: saleskbullmoosetube.com call (800) 882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3201 90' Elbow FIGURE 3201 900 ELBOW Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11/4 500 1.75 0.90 32 3450 44.45 0.41 1 /2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 1 3450 57.15 1 0.84 — Working Pressure Ratings are for reference only and based on Sch. AO pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 -us <S> STED APPROVED Approval Details and Limitations, vebsite at www.anvlllntlxom or n Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3201R Reducing 90' Elbow 2 1 1x2 FIGURE 3201R - REDUCING I 0 ELBOW Nominal Size Max. Working Pressured Dimensions Approx. Wt. Each 1 x 2 A g In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 x /2 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3/4 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 1 t/4 x I/2 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11/4 x 3/4 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11/4 x 1 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11/2 x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 1 I/2 x 11/4 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1/2 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 1/4 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11/4 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11/2 500 2.02 2.16 1.65 50 x 40 1 3450 1 51.30 1 54.86 1 0.75 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 /UR us <S> ISTED APPROVED /Approval Details and Limitations, website at www.anvilintl.com or in Anvil", Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/131I-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGSNvi FIG. 3202 45' Elbow Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (Tim) PSI (kPa) In. (Tim) Lbs. (kg) 1 500 1.12 0.46 25 3450 28.44 0.21 1l/4 500 1.29 0.73 32 3450 32.76 0.33 ll/2 500 1.43 0.92 40 3450 36.32 0.42 2 500 1.68 1.50 50 1 3450 1 42.67 1 0.68 — Working Pressure Ratings are for reference only and based on Sch. AO pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. LISTED APPROVED stings/Approval Details and Limitations, t our website at www.anvlllntlxom or itact an Anvi10 Sales Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3205 Straight Tee A I I I I I STRAIGHT Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressurek In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 1 A 500 1.75 1.22 32 3450 44.45 0.55 1 /z 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 1 3450 1 57.15 1 1.11 — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 LISTED APPROVED tings/Approval Details and Limitations, our website at www.anvilintlxom or act an Anvil• Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3205R Reducing Tee 2 3 1 1 x 2 x 3 FIGURE IREDUCING Nominal Size Max. Working Dimensions Approx. Wt. Each l x 2 x 3 Pressured A B In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x l/z x 1 500 1.50 1.36 1.50 0.64 25 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 3/4 x 1 500 1.50 1.45 1.50 0.73 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 1 x 1 x l/2 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 x 3/4 500 1.37 1.37 1.45 0.76 250500 3450 34.80 34.80 36.83 0.34 1 x 1 x 1 t/4* 500 1.67 1.67 1.58 0.98 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 1 t/z* 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 1 l'A x 1 x t/z* 500 1.34 1.26 1.53 0.82 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 1 t/4 X 1 X 3/4 500 1.45 1.37 1.62 0.90 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 1l/4 x 1 x 1 500 1.58 1.50 1.67 1.00 32 x 25 x 25 3450 40.13 38.10 42.42 0.45 1l/4 x 1 x 1 l/4 500 1.75 1.67 1.75 1.08 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 1l/4 x 1 x 1l/2 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 1 l/4 x 1 l'A x l/2 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 1 34.04 34.04 38.86 1 0.39 Dimensions: ASME B16.3 LISTED APPROVED Itings/Approval Details and Limitations, our website at www.anvilintlxom or tact an Anvils Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. FIGURE 3205R - REDUCING TEE Nominal Size Max. Working PressureA Dimensions Approx. Wt. Each l x 2 x 3 A 7 B PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 t/4 X 1l/4 X 3/4 32 x 32 x 20 500 3450 1.45 1 36.83 1.45 36.83 1.62 41.15 0.92 0.42 1l/4 x 1l/4 x 1 32 x 32 x 25 500 3450 1.58 40.13 1.58 40.13 1.67 42.42 0.95 0.43 1 l/4 x 1 l'A x 1 t/z* 32 x 32 x 40 500 3450 1.88 47.75 1.88 1 47.75 1.82 46.22 1.45 0.66 Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3205R Reducing Tee T ' 2 B' ' 3 T ' A 1 1 x 2 x 3 FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Dimensions Approx. Wt. Each 1 x 2 x 3 Pressured A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11/4 x 11/4 x 2* 500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 11/2 x 1 x /2 500 1.41 1.34 1.66 0.95 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 1 V2 x 1 x 3/4 500 1.52 1.37 1.75 1.14 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 11/2 x 1 x 1 500 1.65 1.50 1.80 1.17 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 1 /2 x 1 x 11/4 500 1.82 1.67 1.88 1.34 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 11/2 x 1 x 11/2 500 1.94 1.80 1.94 1.45 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 1 '/2 xl b x /2 500 1.41 1.34 1.66 1.05 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 11/2 xl'A x 3/4 500 1.52 1.45 1.75 1.15 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 1 /2 x 1 /4 x 1 500 1.65 1.58 1.80 1.25 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 1/2x1/4x2* 500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 P/2x1/2XV2 500 1.41 1.41 1.16 1.15 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 1 '/2 X 1 �/2 X 3/4 500 1.52 1.52 1.75 1.24 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 1'/2 x 11/2 x 1 500 1.65 1.65 1.80 1.30 40 x 40 x 25 3450 41.91 41.91 45.12 0.59 11/2 x 11/2 x 1 �/4 500 1.82 1.82 1.88 1.48 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Dimensions Approx. Wt. Each 1 x 2 x 3 Pressured A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11/2 x 11/2 x 2* 500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 2 x 1 x 2 500 2.25 2.02 2.25 2.15 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 2 x 1'/4 x 2 500 2.25 2.10 2.25 2.30 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 2 x 11/2 x 1/2 500 1.49 1.41 1.88 1.50 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 2 x 11/2 X 1/4 500 1.60 1.52 1.97 1.62 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 2 x 11/2 x 1 500 1.73 1.65 2.02 1.64 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 2 x 11/2 x 11/4 500 1.90 1.82 2.10 1.80 50 x 40 x 32 3450 48.76 46.23 53.34 0.82 2 x 11/2 x 11/2 500 2.02 1.94 2.16 2.00 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 2 x 11/2 x 2 500 2.25 2.16 2.25 2.35 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 2 x 2 x 1/2 500 1.49 1.49 1.88 1.60 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 2 x 2 x 1/4 500 1.60 1.60 1.97 1.68 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 2 x 2 x 1 500 1.73 1.73 2.02 1.85 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 2 x 2 x 11/4 500 1.90 1.90 2.10 2.04 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 2x2x1/2 500 2.02 2.02 2.16 2.18 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 ♦ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3221R Reducing Coupling Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (Tim) PSI (kPa) In. (Tim) Lbs. (kg) 1 x /2 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3/4 500 1.69 0.53 25 x 20 3450 42.92 0.24 — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 C UL us FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintlxom or contact an Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3221 Coupling I I I I FIGURE 3221 - COUPLING Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (Tim) PSI (kPa) In. (Tim) Lbs. (kg) 1 500 1.67 0.40 25 3450 42.42 0.18 11/4 500 1.93 0.57 32 3450 49.02 0.26 11/2 500 2.15 0.75 40 3450 54.61 0.34 2 500 2.53 1.15 50 1 3450 1 64.26 1 0.52 — Working Pressure Ratings are for reference only and based on Sch. AO pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 C UL us FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvlllntlxom or contact an Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3224 Cap A FIGURE 3224 - CAP Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure. In. (Tim) PSI (kPa) In. (Tim) Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 1l/4 500 1.28 0.43 32 3450 32.51 0.20 ll/2 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 1 3450 1 36.83 1 0.41 — Working Pressure Ratings are for reference only and based on Sch. AO pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 C UL us FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvlllntlxom or contact an Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3283 Bushings F_t �B IA M- Inside Head C � F- I� B I �A M- Outside Head FIGURE 3283 - BUSHINGS Nominal Size Max. Working Pressured Dimensions Style Approx. Wt. Each Male (M) x Female (F) A g ( In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) L6s. (kg) 1 x I/2 500 0.75 0.25 1.42 Outside 0.22 25 x 15 3450 19.05 6.35 36.06 0.10 1 x 3/a 500 0.75 0.25 1.42 Outside 0.17 25 x 20 3450 19.05 6.35 36.06 0.08 11/a x 1 500 0.80 0.28 1.76 Outside 0.28 32 x 25 3450 20.32 7.11 44.70 0.13 11/2 x 1 500 0.83 0.31 2.00 Outside 0.45 40 x 25 3450 21.08 7.874 50.80 0.20 11/2 x 11/a 500 0.83 0.31 2.00 Outside 0.30 40 x 32 3450 21.08 7.874 50.80 0.14 2 x 1 500 0.88 0.41 1.95 Inside 0.67 50 x 25 3450 22.35 10.414 49.53 0.30 2 x 11/a 500 0.88 0.34 2.48 Outside 0.73 50 x 3 1 3450 1 22.35 1 8.636 1 62.99 1 1 0.33 2 x 11/2 500 0.88 0.34 2.48 Outside 0.61 50 x 40 3450 22.35 8.636 62.99 0.28 - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.14 LISTED APPROVED Listings/Approval Details and Limitations, iisit our website at www.anvilintl.com or lontact an Anvil" Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 FireLock° Outlet-T STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating V2, 3/4, and 1715, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300psi/2068kPa and VdS rated up to 16bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS JOB/OWNER System No. Location c EL US <FM>vas LPCB Q. LISTED 491a/27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: • Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat -treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America, Asia Pacific) • Red enamel (Europe) CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G Para ✓C-taUI c 10.52_1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock° Outlet-T STYLE 922 DIMENSIONS t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52_2 ✓ctaulic® REV_G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FirpLock° Outlet-T STYLE 922 PERFORMANCE * Hazen -Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Ic- _tau I —id REV_G 10.52_3 FireLock° Outlet-T STYLE 922 INSTALLATION WARRANTY Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ✓c -au lic 10.52 MArhanjcal-TO Bolted Branch Outlets �� FM u�c VdS LPCB VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical -TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross -type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic -Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic -Ball Valve to create the Style 931 Vic -Tap II Mechanical-T unit. See page 8 for further information. STYLES 920 AND 920N STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized JOB/OWNER System No. Location Gasket: (Specify choice*) • Grade "E" EPDM EPDM (Green color code). Temperature range —30oF to +230oF/-34oC to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat -treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. CONTRACTOR Submitted By ENGINEER Spec Sect Para Date Approved www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M ✓ct_au hc 11.02_1 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Merhnnilrai_TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 11 � ^ � m IBM .- -< , 01 GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1/2750 x 15 mm through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Size Nominal Size Style Max. Work No. Pressure@ 920 D. Dimensions Approx. Weight Each Inches mm 2 x '/2 (a) a or psi +0.13 920N kPa 00 920N 500 1.50 Inches Inches mm mm 2.00 2.53 Inches mm _ Inches mm 1.61 Inches Inches Lbs. Lbs. mm mm kg kg 5.35 2.75 3.1 50 15 3450 I 38.1 51 64 41 136 70 1.5 3/4 (a) a 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1 (a) a 920N 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 41 136 70 1.4 1 Y4 (a) to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 Yz (a) to g20N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2Yz x 1/z (a) §a 920N 500 1.50 2.21 2.74 _ 1.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 46 143 70 1A 3/4 (a) §a 920N 500 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 46 143 70 1A 920N 500 2.06 2.74 _ 1.82 5.64 2.75 2.9 1 (a) §a 1.50 25 3450 38.1 52 70 46 143 70 1.4 1 V4 t (a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1/2 t (a) a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 /z (a) 76.1 x 920N 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 _ 15 2065 38.1 56 70 57 164 81 1.8 3/4 (a) 920N 300 1.50 2.19 2.75 _ 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 57 164 81 1.8 1 (a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 1'/4 (a) a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 920N 500 2.28 3.00 3.31 1.92 6.29 3.25 3.5 1 1/2 (a) a 2.00 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 Yz (a) o x 920N 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 _ 80 15 3450 38.1 64 78 58 156 70 1.6 3/4 (a) o 920N 500 1.50 2.49 3.05 _ 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 58 156 70 1.6 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 1'/4 (a) to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32 (b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 920N 500 2.78 3.50 3.56 2.28 6.15 3.25 4.1 1 1/2 (a) to 2.00 3.8 40 (b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) n 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 /z x 2 920N 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2'/2" BSPT clearly on order. § Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 ✓ctaulid REV_M CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Marhanjcal-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1/2750 x 15 mm through 8 x 47200 x 100mm Sty le Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or psi +0.13 Inches Inches Inches Inches Inches Inche s Lbs. Lbs. mm 920N kPa 00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 2 4 V2 (a) 0 x 920N 500 1 1.50 3.03 3.56 _ 2.69 7.01 2.75 3.7 _ 100 15 3450 38.1 77 90 68 178 70 1.8 3/4 (a) 0 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 920N 500 1.50 2.88 3.56 _ 2.75 3.6 1 (a) 0 2.69 7.01 25 3450 38.1 73 90 68 178 70 1.8 1 Y4 (a) to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32 (b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 /2 (a) to 920N 500 1 2.00 3.28 4. 00 4.00 2.69 7.01 3.25 4.2 3.9 40 (b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 920N 500 2.50 4.00 2.69 7.01 3.88 5.0 4.6 2 (a) to 3.25 4.00 50 3450 63.5 83 102 102 68 178 1 99 2.3 2.1 21/2 (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 _ 4.00 2.69 7.34 4.63 _ 6.4 3450 69.9 73 102 68 186 118 2.9 3 (a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 500 1.75 84 114 3.78 105 68 196 130 3.8 2.9 1 /4 (a)o 108.0 x 920N 3.08 _ 2.63 7.64 3.05 5.0 _ 32 3450 44.5 78 96 67 194 78 2.3 920N 3.28 4.00 _ 2.63 7.64 3.25 5.0 1 Y2 (a)o 500 2.00 40 3450 50.8 83 102 67 194 83 2.3 920N 500 2.50 _ 2.63 7.64 4.00 4.0 2 (a) 3.25 4.00 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7. 44 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 3 (a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 2.00 84 4.03 114 4.75 114 4.75 67 3.16 194 9.70 124 3.69 3.1 7.4 3.0 5 1 1/2(a) t x 920 500 7.6 125 40 3450 50.8 102 1 121 121 80 246 94 3.4 3.4 920 500 2.50 4.75 3.16 8.2 8.0 2 (a) t 4.00 4.75 9.70 4.38 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 920 500 4.75 3.16 9.70 4.63 8.3 7.9 2 /2 (a) t 2.75 3.63 4.75 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm n 920 500 2. 55 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 3450 I 69.9 95 121 80 246 118 I 3.6 3 (a) t 500 3.50 920 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 500 2.50 920N 97 127 118 80 4.50 _ 3.17 246 135 3.8 4.0 2 133.0 x 3.75 8.00 3.88 8.0 _ 50 3450 63.5 95 114 81 203 99 3.6 3.81 9.46 5.31 8.0 _ 3 920 500 3.50 5.00 _ 3.00 80 3450 88.9 1 97 127 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2112" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV M ✓ct-au I -id 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Merhnninal_TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS .- Ju " Irl GROOVED OUTLET ro'; P�Iwl FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1/2750 x 15 mm through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Nominal Size 920 D. Inches or psi +0.13 Inches Inches Inches Inches Inches Inche Lbs. Lbs. mm 920N kPa 00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 3 1 1/2t 139.7 x 920N 500 2.00 3.78 4.50 _ 3.30 8.23 3.25 7.0 _ 40 3450 56.8 96 114 84 209 83 3.2 2 t 920N 500 2.50 3.75 4.50 _ 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 84 209 99 4.1 6 1 /4 (a) x 920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 32 (b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 1 Yz (a) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40 (b) 3450 1 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 920 500 2.75 4.01 3.69 10.51 4.63 8.3 2 Y2 5.13 1 5. 22 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 920 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 76.1 mmn 8.4 3450 69.9 105 132 94 267 118 3.8 3 (a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 920 3.81 5.75 5.38 3.69 10.51 6.25 10.1 4 (a) to 500 4.50 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 1 1/2 (a) 159.0 x 920N 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 _ 40 3450 1 50.8 112 130 92 239 83 3.5 2 (a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 50 3450 I 63.5 111 130 92 239 99 3.6 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.634.0 9.40 5.31 8.1 1 80 3450 88.9 110 140 130 92 1 239 135 3.7 6.4 108.Omm 920 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 - 10.0 3450 114.3 113 137 92 239 155 4.5 920 500 4.50 3.81 _ 4 5.75 _ 3.63 9.40 6.25 18.0 100 1 3450 114.3 96.80 1 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2/2" BSPT clearly on order. § Vds approved for fire protection services ❑ LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 ✓ctaulid REV_M CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Marhanjcal-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS lil �� rlRollo ICI GROOVED OUTLET A.%I P-I " Irl FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x V2750 x 15 mm through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. St, le Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. mm 920N kPa 00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 1 165.1 x 920N 500 1.50 3.88 4.56 _ 3.79 9.34 2.75 8.0 _ 25 3450 38.1 99 116 96 237 70 3.6 920N 4.43 3.79 9.34 3.25 8.4 1 Y4 0 500 1 1.75 5.13 _ 32 3450 44.5 113 130 96 237 83 3.8 1 /2 (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 920N 500 2.50 4.38 5.13 5.13 2 (a) t 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 920 500 2.75 3.63 10.51 4.63 8.6 76.1 mm 4.01 5.13 5.21 Z6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3 (a) t o 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2 (a) t x 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 2 /2 (a) t 920 500 2.75 5.07 6.19 6.19 431 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm a 920 500 2.75 5.25 _ 6.25 4.81 12.42 4.56 _ 11.6 3450 69.9 133 159 122 316 116 5.3 3 (a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4 (a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings (a) British Standard female pipe threaded outlet is available as listed. Specify "BSP7 clearly on order. (b)For 76.1 mm threaded outlet, specify 2/2" BSPT clearly on order. § Vds approved for fire protection services o -PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV M ✓ct-au I -id 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Merhnninal_TO Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Exaggerated for clarity Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-r fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Kv Values Values for flow of water at +60*F/+16°C are shown in the table below. Formulas for Cv/Kv Values: AP — Qz Where: AP = QZ Where: C 22 Q = Flow (GPM) K Q = Flow (m3/h) 4P = Pressure Drop (psi) AP = Pressure Drop (bar) Q = CV x 4P Cv = Flow Coefficient Q = K x JAP K = Flow Coefficient OutletEquivalent Length of 0 Carbon Steel Pipe NOMINAL ACTUAL DIAMETER •• GROOVIEID1111111 WTHREADED GROOVED y2 0.840 11 15 21.3 2 9.4 3/4 1.050 16 20 26.7 4 13.7 1 1.315 21 8 25 33.7 1.8 1 y4 1.660 50 48 32 42.7 5 /z 6 42.9 41.1 1 1/z 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.375 112 104 50 60.3 9 1 10 /z 96 89.1 21/2 2.875 119 150 65 73.0 20 1/2 12102 128.5 76.1 mm 3.000 16* 161 76.1 138.1 3.500 249 237 80 1 88 9 14 15 Yz 213.4 203.1 4 4.500 421 1 401 100 114.3 20 22 360.8 343.6 t Hazen -Williams coefficient of friction is 120. * Pipe with a wall thickness of 0. 1 65in./4.2mm. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X, ICt_au I —id 11.02_6 REV_M CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Marhanjcal-TO Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size -1 Sijze, Pipe Rated Working Pressures Agency — psi/kPa Nominal Size DiameterApproval Actual Outside *Outlet Vds c Sc IFu. ' 21/2 - 6 2.875 - 6.625 All 10, 40 400 400 400 290 232 362 65 - 150 73.0 - 168.3 2.875 - 4.500 All DF 2755 2755 2755 1999 1599 2496 21/2 - 4 300 300 300 290 232 362 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 21/2 - 4 2.875 - 4.500 All SF 300 300 300 290 232 362 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 25 3, 4 10 300 300 250 290 232 362 1550 168 3 2065 2065 300 1724 300 1999 599 2496 6 6.625 3,4 30, 40 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 145 2496 8 8.625 21/2 10,40 400 200 219.1 2755 250 1000 145 8 8.625 3,4 10 300 200 219.1 2065 1724 1000 145 8 8.625 3,4 30, 40 300 300 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic -Tap II hole cutting tool is designed for use with the Style 931 Vic -Tap II Mechanical-T unit, 4 - 8"/100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic -Ball Valve. The Vic -Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic -Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5/125mm, 67150mm and 87200 mm diameter pipe. The Style 931 comes with a 21/2"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. AC_ t _au I —id REV_M 11.02_7 Merhnninal_r Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ✓ct-au lic 11.02_L The 115 Standard Duty Loop Hanger is ideal for suspending stationary, non -insulated pipe lines, including CPVC pipes, in fire sprinkler systems. A knurled insert nut helps simplify vertical adjustments and flared edges on the base (1/2" to 4" sizes) help protect pipes from coming into contact with any sharp edges of the hanger. i, Flared edges help prevent any sharp surfaces from coming into contact with the pipe (1/2" to 4" sizes) i, Retained insert nut helps ensure the loop hanger and insert nut stay together i, Recommended for the suspension of stationary non -insulated pipe lines i, Manufactured to use the minimum rod size permitted by NFPA' for fire sprinkler piping i, Conforms with Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society (MSS) SP-58 (Type 10) Material: Steel Finish: Pregalvanized C UL US FM APPROVED IF Part Number Pipe Size Outer Diameter OD Rocs Size RS A B C Static Load F Certifications 1150050EG 1/2" 0.840" 3/8" 213/16" 11/8" 1" 30011b cULus 1150075EG 3/4" 1.050" 3/8" 3" 1 3/16" 15/16" 300 lb cULus, FM 1150100EG 1" 1.315" 3/8" 3 1/4" 1 3/8" 15/16" 300 11b cULus, FM 1150125EG 1 1/4" 1.660" 3/8" 3 9/16" 1 1/2" 15/16" 300 11b cULus, FM 1150150EG 1 1/2" 1.900" 3/8" 3 13/16" 1 5/8" 15/16" 300 tb cULus, FM 1150200EG 2" 2.375" 3/8" 4 1/4" 1 7/8" 15/16" 300 tb cULus, FM 1150250EG 2 112" 2.875" 3/8" 5 9/16" 2 13/16" 1 9/16" 525 1b cULus, FM 1150300EG 3" 3.500" 3/8" 6 9/16" 3 1/2" 1 15/16" 525 1b cULus, FM 1150350EG 31/2" 4.000" 3/8" 71/16" 33/4" 1 15/16" 58511b cULus, FM 1150400EG 4" 4.500" 3/8" 7 9/16" 4" 1 15/16" 650 lb cULus, FM 1150500EG 5" 5.563" 1/2" 9 13/16" 43/4" 2 1/4" 1,0001b cULus, FM 1150600EG 6" 6.625" 1/2" 11 5/16" 6 5/16" 3 5/16" 1,000 lb cULus, FM 1150800EG 8.. 8.625" 1/2" 12 7/8" 6 7/8" 2 7/8" 1,000 lb cULus, FM PENTAIR FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL, UR, cUL, cUR, cULus and cURus are registered certification marks of ILL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. 0 2016 Pentair All rights reserved Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. ►� PENTAIR f, Allows structural attachment to metal beams, bar joist, channel, or angle iron in top mount position only unless used on a parallel flange f, Lightweight, one-piece stamped body provides superior strength and eliminates deficiencies associated with castings f, Spins onto threaded rod and allows for easy adjustment f, Conforms with Federal Specification WW-H-171 (Type 23), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 19) rA rep �� T Sc TQ —I RS f IF Material: Steel Finish: Pregalvanized C UL US FM APPROVED RFEEEE� Roc' Size Flange Screw Diameter Torque Static Load Part Number RS Thickness A C Sc TQ F FT —do SBC037 3/6" 3/4" Max 0.925" 0.85" 1.58" 3/6" 5 ft to 500 lb Set screw must be tightened and torqued onto the sloped side of the I-beam, channel, or angle iron flange. Recognizing that torque wrenches are generally not used or available on many job sites, the setscrew should be tightened so it contacts the I-beam and then an additional 1/4 to 1/2 turn added. ANSI is a registered trademark of American National Standards Institute. FM is a registered certification mark of FM Approvals LLC, LTD. ILL, UR, cUL, cUR, cULus and cURus are registered certification marks of ILL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. 0 2016 Pentair All rights reserved Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. ►� PENTAIR i, Retainer strap for beam clamps RS W L - -17 Material: Steel Finish: Pregalvanized Part Number Rod Size RS Length L Width W 30OC3706EG 3/8" 6" 15/16" 30OC3708EG 3/8" 8" 15/16" 30OC3710EG 3/8" 10" 15/16" 30OC3712EG 3/8" 12" 15/16" 30OC3714EG 3/8" 14" 15/16" 30OC3716EG 3/8" 16" 15/16" 30OC3718EG 3/8" 18" 15/16" 30005008EG 1/2" 8" 15/16" 30005010EG 1/2" 10" 15/16" 30005012EG 1/2" 12" 15/16" 30005014EG 1/2" 14" 15/16" 30005016EG 1/2" 16" 15/16" 30OC6206EG 5/8" 6" 1 3/16" 30OC6208EG 5/8" 8" 1 3/16" 30OC6210EG 5/8" 10" 1 3/16" 30OC6212EG 5/8" 12" 1 3/16" 30OC6214EG 5/8" 14" 1 3/16" 30OC7506EG 3/4" 6" 1 3/16" 30OC7508EG 3/4" 8" 1 3/16" 30OC7510EG 3/4" 10" 1 3/16" 30OC7514EG 3/4" 14" 1 3/16" PENTAIR Part Number Rod Size IRS Length L Width W 30008706EG 7/8" 6" 2" 30008708EG 7/8" 8" 2" 30008714EG 7/8" 14" 2" Field bend and use jam nut over hanger rod to secure. Add 2" to width of flange to determine minimum length strap required. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. 0 2016 Pentair All rights reserved Pentair, CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. ►� PENTAIR FireLock° V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: C � us FM LPCB Q; ® vds E 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex -shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to 3/411/19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Job/Owner System No. Location Contractor Submitted By Date ✓ct_au lic" 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm K Factor: 5.6 Imp./8.1 S.I.1 Nominal Thread Size: 1/2" NPT/15 mm Max. Working Pressure: • 175 psi/1200 kPa (FM) • 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% Q 500 psi/3450 kPa Min. Operating Pressure: • 7 psi/48 kPa • 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart ' For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Engineer Spec Section Paragraph Approved Date B ✓3 j \ m �I Exaggerated for clarity victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. 1 �c_tau lic' victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51OOO Bulb: Glass with glycerin solution Bulb Nominal Diameter: ❑ Standard: 5.0 mm ❑ Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C651OO Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S3O2OO Installation Wrench: ❑ Open End: V27 ❑ Recessed: V27-2 Sprinkler Finishes: ❑ Plain Brass ❑ Chrome plated ❑ White painted3 ❑ Black painted3 ❑ Custom painted3 ❑ Proprietary Nickel Teflon2 coating3 ❑ VC-2504 155, 200, 286 SR Only: ❑ Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. 3 UL Listed for corrosion resistance. 4 UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 ictaulic' victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V27087 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I s 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C FM 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C NYC/M EA 62-99-E 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/681C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 5 For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 7 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulid victaulic.com I Sprinklers I Fire Lock' I K5.6, V27 I Publication 40.10 Dimensions: 23/8 "/ 60 mm 15/$„/ 41 mm Standard Pendent— V2707, V2708 'y6"/ 17 mm 1'M6'7 43 mrr t3/V/60 mm Max. Hole 2"751 mm Min. Hole 216/,6"/ 75 mm MAXIMUM EXTENSION 17A67 37 mm 15/s'/ 23/8,/ 41 mm 60 mm Standard Upright — V2703, V2704 13A67 Typical Ceiling Tile ,',' ser ,' %' 30mm A'7 -Finished Surface) 301nm MAXIMUM RECESS I '/2" Adjustment Recessed — V2707, V2708 (drawing not to scale) 2/e'760 mm Max. Hole 2"751 mm t Min. Hole y 1 1}/ 15f16'7 24 mm 'Mm6 / , , �� �� 37 mm 18m ', , Typical Ceiling Tile , ,' , ,' \— 16/15v Finished Surface 24 mm MAXIMUM RECESS 215/,s'/ 75 mm MAXIMUM EXTENSION 3/4" Adjustment Recessed — V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 iCtS U1 C® victaulic.com I Sprinklers I Fire Lock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns — Trajectory 3.0m 8' 2.4m •�� �� ��• ♦♦ ♦♦ 6' •`. ♦♦♦ 1.Sm •� `� 4' 1.2m '•`• 2' 0.6m 10, 3.Om 8' 2.4m 6' 1.8m 4' 1.2m 2' 0.6m 0 2' 4' 6' 8' 10' O.bm 1.2m 1.8m 2.4m 3.Om Models V2703, V2704 K5.6 Standard Upright Distribution Patterns — Trajectory 2' 4' 68' 10' 0.6m 1.2m 1.8m 2.4m 3.Om 12' 14' 3.7m 4.3m r— f 12' 14' 16' 3.7m 4.3m 4.9m 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7psi 48 kPa 15 psi 103 kPa 30psi 207 kPa NOTES: A. Data shown is approximate and can vary due to differences in installation. B. These graphs illustrate approximate trajectories, floor -wetting, and wall -wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. C. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 iC_taulic' victaulic.com I Sprinklers I Fire Lock° I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67T (-55°C) to those shown in the table below. Temperature — °F/°C V2707, V2708 Pendent Maximum �Nomi V2707, V2708 Recessed Per Sprinkler Victaulic nal Ambient Glass Temperature Part Temperature Temperature Bulb rV2703,V2704Upright Classification Identification Rating Allowed Color Ordinary A 135°1 100°1 Orange Ordinary C 155°1 100°1 Red Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/930C 150°1 Green High J 286°F/141°C 225' 107°C Blue Extra High 7 K 360°F/182°C 300°F/149°C Purple — M Open — No Bulb 7 Standard response only. 8 150/65 if wax coated. V27-2 Recessed v27 Open End dent ✓ - A WARNING • Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating, or any re -coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: _ 001-610-559-3300. Installation Note Reference should always be made to the 1-40 Victaulic Fire Lock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and is available in PDF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 AC—UN_U1iC