Loading...
BLD2022-1333_Manufacturer_Specifications_and_Installation_Instructions_10.3.2022_10.26.20_AM_3141463w O 2 Z W Q W �D V / Q N x 00 a N N O N t U co IWE ,��ce�rca� �S�iaara! HEATING & AIR CONDITIONING LIQUID LINE SERVICE VALVE, "E" I.E. FEMALE BRAZE D CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTIN( H 4 F GAS LINE SERVICE VALVE, "D" I.D. FEMALE FIG. 2 BRAZED CONNECTION ELECTRICALAND REFRIGERANT WITH 1/4" SAE FLARE COMPONENT CLEARANCES PRESSURETAP FITTING. PER PREVAILING CODES. J SERVICE PANEL-� G F GAS LINE SERVICE VALVE, "D" I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. H G yl I _ LIQUID LINE SERVICE / FIG. 3 VALVE, "E" I.D. FEMALE J BRAZED CONNECTION WITH 1/1 SAE FLARE PRESSURE TAP FITTING. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHER TWO SIDES UNRESTRICTED K ELECTRICAL SERVICE PANEL 251111 22.2 (718) DIA. HOLE LOWVOLTAGE 28.6 (1 -1/8) DIA. K.O. WITH 22.2 (718) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY LIQUID LINE SERVICE VALVE, I.D.FEMALE H BRAZE CONNECTION WITH 1/4" SAE FLARE PRESSURETAP FITTINGS J . IK.O. FOR ALTERNATE ELECTRICAL ROUTING FIG.'I G GAS LINE 1/4TURN BALL SERVICEVALVE, np. I.D. FEMALE BRAZED CONNECTION WITH 1/4 SAE FLARE PRESSURETAP FITTING. A Model Base A B C D E F G H J K 4A6V8X24A 3 1035 829 756 16-5/8 10-3/8 127 76 197 57 813 (40-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-1/4) (32) SOUND POWER LEVEL Model Mode Speed A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Cool Min 54 70.9 50.3 51.8 52.3 50.4 42.0 37.7 39.9 Cool Max 65 76.3 65.2 62.7 64.1 60.5 55.7 49.5 45.0 4A6V8X24A Heat Min 60 69.8 52.9 52.8 57.5 55.2 51.9 47.4 46.5 Heat I Max 1 69 75.9 66.0 64.7 67.3 1 65.6 57.0 52.2 47.7 Note: Rated in accordance with AHRI Standard 270-2008 2 4A6V8X24A-SUB-1A-EN Awe eai S-laffdard. HEATING & AIR CONDITIONING OUTDOOR UNIT (a) (b) 4A6V8X24A1000A POWER CONNS. — V/PH/HZ (e) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 17.0 BR. CIR. PROT. RTG. — MAX. (AMPS) 25 COMPRESSOR SCROLL NO. USED — NO. SPEEDS 1-VARIABLE R.L. AMPS (d)— L.R. AMPS 11.5 — 10.2 FACTORY INSTALLED START COMPONENTS (e) NA INSULATION/SOUND BLANKET YES COMPRESSOR HEAT YES OUTDOOR FAN DIA. (IN.) — NO. USED 23 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— VARIABLE CFM @ 0.0IN. W.G. M 2680 NO. MOTORS — HP 1-1/3 MOTOR SPEED R.P.M. 200 — 1200 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 2.8 OUTDOOR COIL — TYPE SPINE FIN TM ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 19.77 TUBE SIZE (IN.) 3/8 REFRIGERANT R410-A LBS. — R-410A (O.D. UNIT) (9) 7 lb — 6 oz FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 5/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10° DIMENSIONS H X W X D CRATED (IN.) 46 X 30.1 X 33 WEIGHT SHIPPING (LBS.) 225 NET (LBS.) 204 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (_) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. M Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Max. linear length 150 ft.; Max. lift — Suction 50 ft.; Max. lift— Liquid 50 ft. Mechanical Specification Options General This unit is designed to operate at outdoor ambient temperatures from 55' F to 120' F in cooling. From — 10° F to 66' F in heating (heat pumps only). Only AHRI approved indoor matches are approved for use with these models. American Standard Link or AccuLinkTm Heat Pumps This outdoor unit contains the American Standard Link or Accul-inkTm Heat Pumps digital communication with 2 wire connection to outdoor and Plug-n-Play set up. Casing Unit casing is constructed of heavy gauge. G60 galvanized steel and painted with a weather -resistant powder paint on all louvered panels and prepaint on all other panels. Corrosion and weatherproof CMBP-G30 DuraBaseTIM Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high and low pressure switches. A factory supplied, field installed filter is standard. Compressor Inverter driven scroll compressor with 25 to 100% output capacity on heat pumps and 30 to 100% output capacity on air conditioners. Noise enclosure minimizes sound levels and built in compressor protection protects compressor will reduce operating speed and current draw to maintain operation while protecting the compressor. Condenser Coil The Spine FinTM outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has built in freeze protection that will allow cooling operation below 55°F but will reduce capacity or shut down completely to prevent operation under adverse conditions. Comfort Control The 1050/950/850 Control is required and provides Plug-n-Play setup and 3 wire connection. 4A6V8X24A-SUB-1 A-E N ,4tice�ie4W SSfidOrd® HEATING & AIR CONDITIONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. C UL US LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A6V8X24A-SUB-1A-EN 03Mar2o22 Supersedes (New) ©2022 American Standard Heating and Air Conditioning