Loading...
FIR2022-0075+Fire_Alarm_Equipment_Specification_Sheets+8.1.2022_4.48.27_PM+3025982City Of Edmonds Building Department --------------------------- Work - FIRE ALARM Address 405 HOWELL WAY --------------------- ----------- ---- Owner ALBERTOS CHURROS ------------------------------ Approved Date -------------------------------- Building Official: Permit Number` FIR2022-0075 ------------- Alberto's Churros 405 Howell Way Edmonds, WA 98020 ��Srimstone F►re Safety Management LLC Description System Sensor SCRL Visual Strobe, Ceiling Mount System Sensor PC2RL Horn Strobe, Ceiling Mount BATTERY CALCULATIONS FOR ALBERTO'S CHURROS DEVICE 07Y. SUPERVISORY ALARM SGRL, 15cd 1 0 .041 PC2RL, 75cd 1 0 .137 1 August 2022 TOTAL SUPERVISORY 0 0 TOTALS: 0.00 Ah SUPERVISORY: 0.00 Ah x 24 HOURS = 0.00 Ah ALARM: .178 Ah x .0833 (5 MINUTES) _ .015 Ah 20% SAFETY MARGIN (ALARM & SUPERVISORY) _ .003 Ah TOTAL SYSTEM CURRENT: .018 Ah THIS SHOULD NOT SIGNIFICANTLY AFFECT THE BATTERY. RECEIVED Aug 02 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TOTAL ALARM .041 .137 1 /6 Ah 20628 Broadway Avenue Snohomish, WA 98296 Office (425) 956-3434 Fax (425) 956-3723 License #BRIMSFS902BL 4,�� SYSTEM Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING & F M LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 RECEIVED Aug 02 2022 CITY OF EDMONDS MENT SERVICES ARTMENT The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 - 12/01/2017 • Page 3 L-Series Specifications RECEIVED Aug 02 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120DF (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02. 12/01/2017 • Page 2 UL Current Draw Data UL Max. Strobe Current Draw (rnA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR RECEIVED Aug 02 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 8-17.5 Volts 16-33Volts Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non -Temporal High 43 47 54 95 N/A 134 164 Non -Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 0.83" di (173 n 2.47" (62.7 mm) 1.37" (34.8 min) Ceiling -Mount Horn Strobes A0545-00 A0494-01 6.92" r+— (175. Ceiling Surface Mount Back Box 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories RECEIVED Aug 02 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2.5' (64 mm) O A0546-00 TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 1-01 SYSTEM ©t to c System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,6,-02ngthe latestversion ofthisdata sheet. AVDS868-02 • 12/01/2017