Loading...
APPROVED BLD BLD2022-0699+Architectural_Plan+5.27.2022_8.01.37_AM+2897421M :EPEW 10 LEGAL DESCRIPTION THAT PORTION OF THE NORTHEAST QUARTER OF THE NORTHWEST QUARTER OF SECTION 9, TOWNSHIP 24 NORTH, RANGE 5 EAST, W.M., LYING WESTERLYOF NORTHERN PACIFIC RIGHT-OF-WAY; ALSO, THAT PORTION OF GOVERNENT LOT 1 IN SECTION 9, TOWNSHIP 24 NORTH, RANGE 5 EAST, W.M.M LYING EASTERLY OF BOUNDARY OF FACTORIA-WILBURTON COUNT ROAD AND WESTLY OF THE WESTERLY BOUNDARY OF NORTHERN PACIFIC RIGHT-OF-WAY. PER RECORD OF SURVEY DATED DECEMBER 1981 PREPARED BY BENNETT P.S. & E., INC. GENERAL Hidden Meadows Condominiums, is located at 8015 196th St SW, Edmonds, WA 98026. CODE DATA OCCUPANCY CLASSIFICATION R-2 MULTI -FAMILY RESIDENTIAL ZONING DISTRICT R-20 TRANSITION (SINGLE-FAMILY) W/CONDITIONS SCOPE OF REPAIRS The project is to replace the deck rails, sheathing, and soffits for 11 decks. it 1. 2. 3. 4. II. 1. 2. if 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Demolition: Decks: Remove and dispose of the plywood sheathing. Remove and dispose of the existing fascia. Remove and dispose of the existing deck rails. Remove and dispose of the deck soffits. Allow the Engineer to review the exposed deck structure for rot or deficiencies. ,k., A.1..>>,>>>>>>>>>,>>>>>>,>>>.>>,>kkk>k,>>>>>> Decks: Replace the existing 4x6 deck beams with new 4x8 deck beams to stiffen the deck. Install a 2"x6" doubler at each joist to stiffen the deck structure Install a 211x10" doubler outside of of the beam to support new rail system Install Strong -Tie LU-26 joist hangers at all deck joists. Install Strong -Tie L50Z bracket at the north and south rim joist locations. Install new 2"X10" doubler at the north and south ends of the deck structure Install new 2"X10" rim joist with a 2"x10" doubler at the outer edge of the deck with Strong -Tie L50Z brackets. Install new 5/4x12 cedar fascia. Install new 3/4" ACX sheathing. Install new deck flashing. Apply a new deck coating or membranes. Install new Vista Pro rails per manufacturer's instructions. Install the 1/2" Densglass deck soffits with new vents. OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work 11 UNITS- DECK REBUILDS Address 8015,8017,8019196TH ST SW Owner HIDDEN MEADOWS CONDOS --------- -- - - --------------------- ------------------------------------ Approved Date 6/22/2022 Building Official W. W vfk c •--------------------------------------------------- Permit Number all ermits listed to the rl ht ' 4 � e ❑iris;,-. y'nrnr,McDrive ry - Isar• v Lire,sutigcffr'e• a 5eavieW Palk aSeatlie Granafa ComVanyl R1c•77u K::r•'jr Hun Park a rt laRrNVILLE } e - lgAiMS 5W t8p[h Sl SW � LynndelE Park � � � Lys Reoeauor) � p � � �Cos�Ca $usiness CEnter d - — b HDi519fith S1 SW r:"tl WvY , *Emmnn¢s, wA 0002v I Nu tea` - ua �e t j Lynnwood 5�+ — :'.gym sr sw _ y n Lyn nwooaiceceitite v Srnbe caapers sr EC[n?r . a THE SaWL _ QFEDMONDS CiN .'f L}'nnwrojft � Mur.•iUpaf ,•:,Ir Cod•se � .I Llnitc7 3:atc•s 4 �. an;�dl c2,4i: c Edmonds �8 � � A0 ■ 208165%Sw SEAiTLE1.1MIATS YOM SL Elm -Matt, Zsvr B f ALL PERMIT NUMBERS BLD2022-0698 BLD2022-069'9 BLD2022-0700 BLD2022-0701 BLD2022-0702 BLD2022-0729 BLD2022-0730 BLD2022-0731 BLD2022-0732 BLD2022-0733 BLD2022-0735 DEPEW, Inc. 1834 SW 152nd St. Burien, WA 98166 steve@depewinc.com STAMP THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE DOCUMENT THAT IN MY PROFESSIONAL JUDGEMENT ARE APPROPRIATE TO SATISFY THE REQUIREMENTS OF RCW 64.55.005 THROUGH 64.55.090. STEVEN K. DEPEW, PE CO U) 0 Q W Z 75 Z 0 W Q 0 Z 0 0 I U SHEET TITLE 0 z J Q J �a v� W J 0 PRINCIPAL IN CHARGE STEVEN K. DEPEW PROJECT TEAM DEPEW, REVIEWED STEVEN K. DEPEW DRAWN STEVEN K. DEPEW No dimensions should be scaled from drawings and all dimensions and values should be checked and verified against field conditions. If any dimensions are found to be incorrect or invalid, then it is the responsibility of the user to inform the Architect, and to obtain the correct dimensions prior to acting upon anything contained in these drawings. Contractor to verify all dimensions, conditions, etc. pertaining to the Work on site before proceeding with the Work. Copyright 2015 DEPEW, INC. All rights reserved. REVISION DATE PERMIT 03.25.2022 RECEIVED Jun 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NUMBER I SHEET NUMBER EXISTIr EXIS STF 01 EXISTING 2"X10" EXISTING DECK JO NEW STRONG -TIE L90Z FRAMING ANGLES (TYP; NEW 2x10 RIM JOIST (TYP 4 NEW BEAM 'BC' POST CA EXISTING P A SECTION THROUGH DECK 200 / 3/411 = 1 1-011 JCTURE NEVV D/-+ AIL CEDAR FASCIA (TYP) —1/2 " DECK S HER (TYP 2) EXISTING JOIST PER VISTA PRO NG DETAIL c \ GUARDRAIL TO RIM CONNECTION 200 / 31 1 = 1 '-011 NEW EXPOSURE S FOLLOWS: 31 "x 2 2" @ 1 >> I /IVVLLV \I/...............................................U. 131 x 2 2 @ -IVLL L nTNP_R qi ippORTS, FIELD NAILING (FN)..............0.131 "x 2 2" @ JTERIOR RIM JOISTS & STRUTS ....... 0.131 "x 2 2" N EXIST 1 APA—RATED SHEATHING OF e SECTION THROUGH DECK 200 / 3/411 = 1 1-011 Brian West, PE Smith Company Structural Engineers Email: brian.west@ SmithCompany Structural Engineers.com STAMP G. R W �w t 8168 22-0524 3: C/) O75 Q — W Z Z O W p 0 Z 00 2 U SHEET TITLE 0 Z_ W J W H PRINCIPAL IN CHARGE STEVEN K. DEPEW PROJECT TEAM DEPEW, INC. REVIEWED BRIAN WEST DRAWN STEVEN K. DEPEW No dimensions should be scaled from drawings and all dimensions and values should be checked and verified against field conditions. If any dimensions are found to be incorrect or invalid, then it is the responsibility of the user to inform the Architect, and to obtain the correct dimensions prior to acting upon anything contained in these drawings. Contractor to verify all dimensions, conditions, etc. pertaining to the Work on site before proceeding with the Work. Copyright 2015 DEPEW, INC. All rights reserved. REVISION DATE PERMIT 03.25.2022 RECEIVED Jun 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NUMBER I SHEET NUMBER T WALL DEPEW, Inc. ADJACENT 1834 SW 152nd St. / Burien, WA 98166 steve@depewinc.com NEW ACX /ice /ice ii SHEATHING /ice /ice /ice STAMP I J2 A INSTALL 9" HIGH WRB TARGET THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE DOCUMENT THAT IN MY PROFESSIONAL JUDGEMENT ARE APPFLASHING RCWROPRIATE TO SATISFY THE 64.55005 THROUGH 64.55.090REMENTS OF STEVEN K. DEPEW, PE U) STEP 1: DECK COATING AND FLASHING 3: NTS v ) O75 0 W z z0 W0 6„ z o ' = U I I SHEET TITLE / W z DECK CORNER Q 4 FLASHING 0 W 0 m a LLB W 2 LU Q W 0 2 STEP 2: DECK COATING AND FLASHING WP-2. NTS PRINCIPAL IN CHARGE STEVEN K. DEPEW PROJECT TEAM DEPEW, REVIEWED STEVEN K. DEPEW DRAWN STEVEN K. DEPEW WALL ADJACENT No dimensions should be scaled from drawings and all dimensions and values should be checked and verified against TURF �/% /// //� / field conditions. If any dimensions are /ice /ice found to be incorrect or invalid, then it is the responsibilityof the user to inform the /ice /ice Architect, and to obtain the correct �� /ice /ice - NEW ACX -� /ice /ice / dimensions prior to acting upon anything /ice /ice SHEATHING �� � /ice /ice contained in these drawings. Contractor to verify all dimensions, conditions, etc. pertaining to the Work on site before proceeding with the Work. Copyright 2015 DEPEW, INC. All rights reserved. INSTALL 26 GAGE DECK REVISION DATE CORNER FLASHING INSTALL 26 GAGE DRIP PERMIT 03.25.2022 EDGE FLASHING OVER DECK CORNER FLASHING RECEIVED .tun 07 2022 s STEP 3: DECK COATING AND FLASHING OF CITY OF EDMONDS NTS DEVELOPMENT SERVICES DEPARTMENT PROJECT NUMBER SHEET NUMBER WP 201 ---------- - T DEPEW, Inc. 1834 SW 152nd St. Burien, WA 98166 steve@depewinc.com STAMP K �pF2 " e NOTES: 1. THE MAXIMUM GAP BETWEEN ANY OF THE RAILING STRUCTURE TO ITSELF, DECK OR WALL SHALL THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE BE 4". DOCUMENT THAT IN MY PROFESSIONAL JUDGEMENT ARE 2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. APPROPRIATE TO SATISFY THE REQUIREMENTS OF RCW 64.55.005 THROUGH 64.55.090. 3. INSTALL BRACKETS ATTACHING THE TOP OF THE RAIL TO THE WALL ON BOTH STEVEN K. DEPEW, PE SIDES OF THE DECK U) U) O� Q Q — wz_ zp Wp z 0 O RAILING MOUNTING = 1 �J FASTENERS. 3/8" x 4-1/2" STAINLESS STEEL HEX BOLT BLACK OXIDIZED (TYP) SHEET TITLE INSTALL BRACKETS ATTACHING THE LA TOP OF THE RAIL TO THE WALL ON BOTH SIDES OF THE DECK 2X10 RIM JOISTS NEW 5/4"X12" CEDAR FASCIA (TYP) ♦^ V Z E: 0 PEAK RAILING WITH A 4" MAX GAP BETWEEN SPINDLES, RAIL AND DECK AND O Z RAIL AND VERTICAL WALL. O W J a. DECK RAIL 3 RAILING ATTACHMENT � a 201 NTS IVIP-20 NTS 0 PRINCIPAL IN CHARGE STEVEN K. DEPEW PROJECT TEAM DEPEW, REVIEWED STEVEN K. DEPEW DRAWN STEVEN K. DEPEW No dimensions should be scaled from drawings and all dimensions and values should be checked and verified against field conditions. If any dimensions are found to be incorrect or invalid, then it is the responsibility of the user to inform the Architect, and to obtain the correct dimensions prior to acting upon anything contained in these drawings. Contractor to verify all dimensions, conditions, etc. pertaining to the Work on site before proceeding with the Work. Copyright 2015 DEPEW, INC. All rights reserved. REVISION DATE PERMIT 03.25.2022 RECEIVED Jun 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NUMBER SHEET NUMBER ---------- WP - 202 Intertek Testing Services Vista Railing Systems Inc. May 17, 2000 ETL SEMKO Report No. 481-1414 Page 2 of 2 SUMMARY The welds broke at the bottom rail of test samples #1 and #3. The welds broke at the top rail of test sample REPORT OF: Railing Component Testing #2 AT: Coquitlam Laboratory DATE: May 17, 2000 PROJECT: 481-1414 NO: 30/00 INTERTEK TESTING SERVICES NA LTD. REPORTED TO: Vista Railing Systems Inc. PAGE: 1 of 2 Warnock Hersey 23282 River Road i Maple Ridge, B.C. V2W 1136 Attention: Mr Peter Siemens APPENDIX INTRODUCTION Reported by: V Doug Doc erty,AScT Intertek Testing Services NA Ltd./Warnock Hersey, at the request of Vista Railing Systems Senior T [9nologist Inc., has conducted uniform load tests on the aluminum picket infill panels of guardrail Building Sciences assemblies . The tests were conducted on three separate samples in accordance with instructions from Vista Railing Systems Inc. DESCRIPTION Reviewed by: Sheldon Warman, P.Eng. The aluminum picket samples were installed within a complete aluminum guardrail assembly. Manager The pickets measured 5/8" x 5/8" x 0.051" thick and were spaced 4-1/2" apart c/c. Each Physical Testing and Certification picket is welded to both the top and bottom rails on one side each. Every 5th picket is welded on both sides' top and bottom. Please refer to the drawing in the appendix of this report. DD/ah The sample assembly was placed onto a horizontal support assembly and a hydraulic ram (complete with a calibrated 1000 lb. Artech load -cell S/N: 199766) was used to apply the load through a 12" x 12" x 1" thick plywood platten. The load was steadily increased until failure occurred at which point the load was recorded. CA480%reports\alco-30. doc The following table identifies each of the three tests and their results. SAMPLE IDENTIFICATION: 1-001 Irillop.1111 loll III I .... 60 ... . 624 774 691 All services undertaken are subject to the following general policy: Reports are submitted for the exclusive use of client to whom they are addressed. Their significance is subject to the adequacy and representative character of the sample and to the comprehensiveness of the tests, examinations or surveys made. No quotations from reports or use of Intertek Services NA Ltd.'s narte is permitted except as expressly authorized by Intertek Testing Services NA Ltd. in writing Intertek Testing Services NA Ltd. Warnock Hersey 211 Schoolhouse Street, Coquitlam, BC V3K 4X9 Canada �rart:o ® Telephone 604-520-3321 Fax 604-524-9186 Home Page www.worldiab.com Q ra Q� rii T o . t • — • — • — • — • — • — • — • — • — • — • — o n- 1- z IGUARDRAILS SHALL BE DESIGNED TO RESIST A L0� o Y N 9 CONCENTRATED LOAD OF 200 POUNDS IN ANY 0 0 000 `� �oIA I DIRECTION AT THE TOP OF THE GUARDRAIL. _ 00 z z C4 s E .INFILL COMPONENTS SHALL BE DESIGNED TO > o =co, a I RESIST A HORIZONTAL LOAD OF 50 POUNDS min !OVER A ONE SQUARE FOOT AREA. Z 0 X III`■�■�■�■�■�■�■�■�0�0�M \ ZuJ > W Z 00 W ON W \ v f 0Ln la 0� r■�■�■�■�■�■�■�■�■�■�■, o a wI Any welding on site to be completed by a certified U welder or a certified WABO welding shop. �WABO ILL]IL On 0 � J W C/) 3: W Iz ~OW 0W C) 0 Cn LU O,W 00 cn—= cn— U) FF-CLLL F-0 Wa-W WZ Nc�O O U U Q IL W Z 0 F 0 th W J U) a o � J ,a w a Z e "� �m H � x fn nw Z w U O d I —I a w , 0 o00 O aQa n w W .a:------- o o z U p. a wz I I L-- m o 1 M EPEW DEPEW, Inc. 1834 SW 152nd St. Burien, WA 98166 steve@depewinc.com STAMP THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE DOCUMENT THAT IN MY PROFESSIONAL JUDGEMENT ARE APPROPRIATE TO SATISFY THE REQUIREMENTS OF RCW 64.55.005 THROUGH 64.55.090. STEVEN K. DEPEW, PE Ny L00-00 U) w0 00 01� Z w0 2 U SHEET TITLE< G V Z C/) IL 0 O J a. Q W W W �e F_ Q 0 W PRINCIPAL IN CHARGE STEVEN K. DEPEW PROJECT TEAM DEPEW, REVIEWED STEVEN K. DEPEW DRAWN STEVEN K. DEPEW No dimensions should be scaled from drawings and all dimensions and values should be checked and verified against field conditions. If any dimensions are found to be incorrect or invalid, then it is the responsibility of the user to inform the Architect, and to obtain the correct dimensions prior to acting upon anything contained in these drawings. Contractor to verify all dimensions, conditions, etc. pertaining to the Work on site before proceeding with the Work. Copyright 2015 DEPEW, INC. All rights reserved. REVISION DATE A. CORRECTIONS 07.15.2021 RECEIVED Jun 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NUMBER I SHEET NUMBER ---------- I WP - 204A