Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2020-1167+Manufacturer_Specifications_and_Installation_Instructions+12.11.2020_9.30.36_AM
RESUB 111111111MININS "*A Cap & Whisk - - • G ��;�:�� 1 U71 i q nr. 7g,,�►`J�.��_'1'Il►lam Hydroflame Pro Series Sleeves CD Plate (optional) Safety Cap & Locator Whiskers Included (Shown with optional CD Plate) (OSHA Compliant Hole Cover) * Note: Dimension Chart Size Dim "A" Dim "B" Dim "C" Pipe Size HFP-1* 4-1/4" 3-3/4" 8" - 12" '/2" - 1" HFP-2* 4-5/8" 3-7/8" 8" - 12" 1 '/4" - 2" HFP-3* 5-5/8" 5" 8" - 12" 2" - 3" HFP-4* 6-1/2" 6" 8" - 12" 3" -4" HFP-6* 9-1/4" 8-7/8" 8" - 12" 5" - 6" • Height range: 2-1/2" to 12". • Height range: 2-1/2" to 7-3/4" (%B" version). • Both standard & %B" style can be extended by adding sleeving extension. • Sleeves with black Bases & black Locator Whiskers are for use with metallic penetrants. • Sleeve with red Bases & red Locator Whiskers are for use with either metallic or non-metallic (plastic) penetrants. • The use of the Locator Whiskers is optional. Non -Telescoping Version V'-B" 1 k „C„ )ing) The HOLDRITE® Hydroflame Pro Series Sleeving System consists of UL & cUL listed assemblies that provide sleeving & firestop solutions for cast -in -place concrete floors. These sleeve products provide solutions for both metallic & non-metallic pipes, line -sets, cables, conduits, floor drains, tub drains, shower drains and toilet drains. For slabs 2'/2" and thicker and for pipes, conduits & cables'/z" - 6" nominal; 2 & 3 hour UL Fire Ratings and T, L & W- ratings available. 50 Pa ratings available. See UL Fire Resistive Directory (R25101) for further details. Sleeves are easly adapted for use on Corrugated Metal Decking with the use of HoldRite's CD Plates. 16 models include: #HFP-P/M1 (B), #HFP-P/M2 (B), #HFP-P/M3 (B), #HFP-P/M4 (B) and #HFP-P/M6 (B). Product Information: Material: Main Sleeve Body & Safety Cap: Polypropylene Mid -Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Locator Whiskers: Nylon Fire Ring: 24GA CRS Firestop Material: UL Listed Intumescent Composite Patented & Patents Pending • See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. HIS INFORMATION 13 PROPRIETARY TO HOLDRITE AND IS SUBJEC TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. CL us HOLDRITE III DIE III cee �IIJill" PRE BERIES Product Submittal Job Name: um ner: 800-321-0316 OR 760-744-6944 / FAX:760-744-0507 / WWW.HOLDRITE.COM spec_HFP Series, pg1 of 12_RevA PRO[YE ING Hydroflame Pro Series - Tub Box )x ASsy 1-1 /2" Donut (Optional With "NP" Model) RESUB Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 13-3/4" 12 1/2" (Foam Length) 12- 10-1 /4" 10-3/4" (Std. Height) (Can Be Modified) The HOLDRITE® Hydroflame Pro Series "Tub Box" is a UL-Listed firestop device for bathtub drains. Metallic or non-metallic drain piping can be used. Thin wall drain piping requires a rubber tub box donut (included with the #HFP-TW-0200 Kit). Nominal IPS sized drain piping does not provide a rubber donut (not included with the #HFP-NP-0200 Kit). The nominal IPS size donut is optional and can be purchased separately (#HFPTB-1.5 NP). Standard tub box assembled height is 10-3/4". Kit can be cut shorter or sleeve extensions #HFPE2 can be added to make the tub box taller. Product Information: Material: Tub Box Body, Leg Feet, Box Adapter: ABS Rear Legs: PVC Box Insert: Styrofoam Sleeve: See material listed on Spec. Sheet for #HFP-P2 Sleeve. Patented & Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. `S�ff TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN 4 PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. C WL us HOLDRITEA ii H Y 1] 1101-1-A NI 1_T"' 'rl PRO SERIES o-,m�cev�mi llll�l 800-321-0316 OR 760-744-6944 / FAX:760-744-0507 / WWW.HOLDRITE.COM spec_HFP Series, Tub Box, pg5 of 12_RevA I Product Submittal ner: Dec 11 2020 Hydroflame Pro Series - Shower Drain SleeveCITYOFEDMONDS DEVELOPMENT SERVICES DEPARTMENT Shower Drain Sleeve The HOLDRITE® Hydroflame Pro Series "Shower Drain Sleeve" (#HFP-SH2-DRN) is ideal for 2 drain bodies that are recessed into the concrete floor, such as with a shower pan or shower stall. This is a UL Listed Firestop Device that includes a water -tight mid -body seal and built-in firestop materials. The Sleeve is adjustible in height for slabs 5" and thicker and provides a 3-hour F-rating. Optional "CD Plate" can be used when mounting to metal pan deck forms. Upper assembly includes a styrofoam insert pad, to block concrete during pour. Product Information: Material: Main Sleeve Body, Base & Drain Receiver: Polypropylene Mid -Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Firestop Material: LIL Listed Intumescent Composite Insert: Styrofoam Patended & Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest LIL Fire Resistive Directory file (R25101) for details. `S�ff TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. C UL us HOLDRITE' MADE IN 1A Y 1] 1101-1-J� 1�11-T"" o-,mn USAljlPFID SERIES Product Submittal Job Name: ner: 800-321-0316 OR 760-744-6944 / FAX:760-744-0507 / WWW.HOLDRITE.COM spec_HFP Series, Shower Drain Sleeve, pg9 of 12_RevA HYDROFLAME SLEEVES RESUB Inverted Areator Adal Hydroflame Sleeve Firestop (built 2" Pit SHOWER DRAIN 2" SLEEVE (shower pans / stalls) CAST -IN -PLACE FIRESTOP DEVICE ES The HOLDRITE® HYDROFLAMETM Pro Series Shower Drain Sleeve provides a UL listed firestop solution for 2" drain bodies. See UL Fire Resistance Directory for details. (Drain body and pipes by others). TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. HDLDRITEJ 11YO�RO I_AI I_TPRO SER 800-321-0316 OR 760-744-6944 / FAX: 760-744-0507 / WWW.HOLDRITE.COM / 50-005711-000, RevA (Floor & Shower Drain 2" Sleeve) Dec 11 2020 Hydroflame Pro Series - Closet Flange SleeveTYOFEDMONDS DEVELOPMENT SERVICES DEPARTMENT Closet Flange Sleeve ✓BCD Plate (optional) �6 i� The HOLDRITE® Hydroflame Pro Series "Closet Flange Sleeves" are UL Listed Firestop Devices that accept 3" or 4" plastic or no -hub closet flanges and drain pipes. They provide 3-hour "F" & "T" ratings and also "L" & "W" ratings for concrete slabs 2-1/2" and thicker. Sleeves have a mid -body seal and built-in firestop materials. Optional "CD Plate" can be added for use on metal deck forms. Models include #HFP-CF3PL (B), #HFP-CF4PL (B), #HFP-CF3NH (B) and #HFP-CF4NH (B). Product Information: Material: Main Sleeve Body, Base & Safety Cap: Polypropylene. Mid -Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Locator Whiskers: Nylon. Fire Ring: 24GA CRS. Firestop Material: UL Listed Intumescent Composite. Patended & Patents Pending. • See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. `S�ff TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. C UL us HOLDRITE' MADE IN 1AY 1] 1101-1-AM ET"" o-,m�cevvnac UllllA'' PFID SERIES Product Submittal Job Name: ner: 800-321-0316 OR 760-744-6944 / FAX:760-744-0507 / WWW.HOLDRITE.COM spec_HFP Series, Closet Flange Slaves, pg11 of 12_RevA Minimum 6" Concrete Slab OPS-PL40-0300 HYDROFLAME SLEEVES RESUB Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES �3" or 4" Closet Flange (by others) DEPARTMENT 4" Sch. 40 PVC Sleeve Extension d -.. d a Q a d Q d d a d d dd dp Q d d d a a d a d '—Fire Ring Fire Stop Material 3" PVC Waste Pipe (by others) WATER CLOSET SLEEVE CAST -IN -PLACE FIRESTOP DEVICE The HOLDRITE® HYDROFLAMETM sleeve provides a UL listed firestop solution that also serves as a smoke and water seal around the 3" drain pipe. Closet flange not included. See UL system drawings for detail. HIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. N 0 L 0 IIH 1 HYDRO;4, 71��HE SLEEVING SYSTEMS 800-321-0316 OR 760-744-6944 / FAX: 760-744-0507 / WWW.HOLDRITE.COM / 50-005681-000, RevA (OPS-PL40-0300 Closet Flange Sleeve) HYDROFLAME SLEEVES Water Closet / Toilet (by others) Closet Flange (by others) d V ° /d v G a - d< c d n a . 3" or 4" Pipe (by others) RESUB Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Firestop Material (built-in) TOILET FLANGE SLEEVE CAST -IN -PLACE SLEEVE Hydroflame Sleeve Concrete The HOLDRITE® HYDROFLAMET"' Pro Series cast -in -place sleeve provides a UL listed firestop solution for 3" or 4" drain pipe. Closet flange not included. See UL Fire Resistance Directory for details. HIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. HDLDRITE" H D R EI1= I_A I ET" PRO SERIES 800-321-0316 OR 760-744-6944 / FAX: 760-744-0507 / WWW.HOLDRITE.COM / 50-005704-000, RevA (Toilet Flange Sleeve) PRO NYMOEO _ I N G RESUB Dec 11 2020 Hydroflame Pro Series - Floor Drain Sleeve CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT ------------ Floor Drain Sleeve The HOLDRITE® Hydroflame Pro Series "Floor Drain Sleeves" are designed to accept 2", 3", 4" & 6" cast iron floor drains, with neo-lock style rubber gasket outlet. The Sleeve is cut to the desired height and the Sleeve is secured to the form deck by the installer's prefered method. The Sleeve includes a Mid -Body Seal to enhance water -tightness. (Drain NOT included). Models include #HFP-2CI-DRN thur #HFP-6CI-DRN. Product Information: Material: Main Body & Base: Polypropylene. Mid -Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Patented & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. `S�ff TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. C WL us HOLDRITE' rnaoe IN 1AY 13I1(3I-1-JAM E-rm emcee UIIA, PRO SERIES 800-321-0316 OR 760-744-6944 / FAX:760-744-0507 / WWW.HOLDRITE.COM spec_HFP Series, Floor Drain Sleeve, pg8 of 12_RevA Product Submittal Job Name: ner: HYDROFLAME SLEEVES RESUB Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HEMBRITE" HYDRO 44 mr TM SLEEVING SYSTEMS Certificate of Compliance Subject: General Certification of Compliance for Holdrite® HydroFlameTM Sleeving Systems Reference: UL File Number R25101. Holdrite® Certifies that HydroFlameTM Sleeves bearing the UL label have been manufactured and tested to meet the requirements of ANSI / UL 1479 (ASTM E 814), CAN/ULC-5101 "Fire Tests of Through -Penetration Firestops", and are listed under the UL File Number noted above. One or both of the following Markings and Classifications apply: �y� S"P.Alt.Q FIRESTOP DEVICES U FOR USE IN THROUGH -PENETRATION FIRESTOP SYSTEMS SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY 3LHH Quality Manager Vice President C UL us HYDROFLAME SLEEVES RESUB Dec 11 2020 Page Bottom CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT System No. F-A-2221 XHEZ.F-A-2221 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems XHEZ7 - Through -penetration Firestop Systems Certified for Canada See General Information forThrough-penetration Firestop Systems See General Information forThrough-penetration Firestop Systems Certified for Canada System No. F-A-2221 January 31, 2013 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 2 and 3 Hr (See Item 3) F Rating - 2 and 3 Hr (See Item 3) T Rating - 0 and 3 Hr (See Item 3) FT Rating - 0 and 3 Hr (See Item 3) L Rating At Ambient - Less Than 1 CFM/sq ft FH Rating - 2 and 3 Hr (See Item 3) L Rating At 400 F - Less Than 1 CFM/sq ft FTH Rating - 0 and 3 Hr (See Item 3) W Rating — Class 1 (See Item 5) L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft HYDROFLAME SLEEVES RESUB 11-1— 11 OrYrnn 1. Floor Assembly — The fire -rated concrete and fluted steel deck floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete — Min 2-1/2 in. (64 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete topping, as measured over crests of fluted floor units. B. Steel Floor and Form Units* — Composite or noncomposite nom 3 in. (76 mm) deep fluted galv units as specified in the individual Floor -Ceiling design. Diam of opening cut through fluted floor unit to be maximum 1/4 in. (6 mm) larger than outside diameter of bottom extension portion of firestop device base. 2. Firestop Device* — Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) Firestop Device 1/2 to 1 (13 to 25) CD-PL-0200 or CD-OPS-PL-0100 1-1/4 to 2 (32 to 51 CD-PL-0300 or CD-OPS-PL-0200 2-1/2 to 3 (64 to 76) CD-PL-0400 or CD-OPS-PL-0300 3 to 4 76 to 102) CD-PL-0500 or CD-OPS-PL-0400 5 to 6 (127 to 152) CD-PL-0800 or CD-OPS-PL-0600 SECURUS INC, DBA HOLDRITE — Hydro Flame CD-PL, Hydro Flame CD-OPS-PL 3. Through Penetrant — One nonmetallic pipe or conduit to be installed within the firestop device. Pipe or conduit to be installed in accordance with firestop device installation instructions and rigidly supported on both sides of floor assembly. The following types of pipe, conduit or tubing may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. When nom 5 in. or 6 in. (127 or 152 mm) diam PVC pipe is used, F Rating is 2 hr and T Rating is 0 hr. When max 4 in. (102 mm) diam PVC pipe is used, F Rating is 3 hr and T Rating is 3 hr. B. Rigid Nonmetallic Conduit+— Nom 6 in. (152 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code (NFPA No. 70). When nom 5 in. or 6 in. (127 or 152 mm) diam PVC conduit is used, F Rating is 2 hr and T Rating is 0 hr. When max 4 in. (102 mm) diam PVC conduit is used, F Rating is 3 hr and T Rating is 3 hr. C. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 6 in. (152 mm) diam (or smaller) SDR 13.5 (or heavier) or Schedule 40 CPVC pipe for use in closed (process or supply) piping systems. When nom 5 in. or 6 in. (127 or 152 mm) diam CPVC pipe is used, F Rating is 2 hr and T Rating is 0 hr. When max 4 in. (102 mm) diam CPVC pipe is used, F Rating is 3 hr and T Rating is 3 hr. D. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 4 in. (102 mm) diam (or smaller) ScRe'dLilPUsbQR1l,TK A84�Tbr"uUclosed (proces��RpQ ESUB supply) or vented (drain, waste or vent) piping systems. When max 4 in. (Io iiTitl)1 1 2020 diam ABS pipe is used, F Rating is 3 hr and T Rating is 3 hr. CITY OF EDMONDS DEVELOPMENT SERVICES E. Cross -Linked Polyethylene (PEX)Tubing — Nom 2 in. (51 mm) diam (or smaW@R�RTMENT SDR 9 PEX tubing for use in closed (process or supply) piping systems. When max 2 in. (51 mm) diam ABS pipe is used, F Rating is 3 hr and T Rating is 3 hr. 4. Packing Material— (Optional, Not Shown) - Min 2 in. (51 mm) depth of min 4 pcf (64 kg/m3) mineral wool batt insulation tightly -packed into annular space with its top surface flush with the top surface of the floor. When optional sealant (Item 5) is used, top surface of packing material to be recessed min 1/4 in. (6mm) from top surface of floor. 5. Fill, Void or Cavity Material* - Sealant — (Optional, Not Shown) - Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Sealant to lap min 1/2 in. (13 mm) onto top surface of concrete around perimeter of firestop device. W Rating applies only when sealant is used. 3M COMPANY 3M FIRE PROTECTION PRODUCTS — FB-1000 INS, FB-3000 WT or FB-1003 SL *Bearing the UL Classification Mark +Bearing the UL Listing Mark Last Updated on 2013-01-31 Questions? Print this page Terms of Use Page Top © 2014 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2014 UL LLC". 10/10/2014 HY[(JrfAK'tpaCC�/tems RESUB nL1IILIC r+C0TIC10ATInwc n10CrhTA12V VCJF_tDec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT System No. F-B-2042 XHEZ.F-B-2042 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems System No. F-B-2042 June 14, 2011 F Ratings — 2 and 3 Hr (See Item 3) T Ratings — 0 and 3 Hr (See Item 3) W Rating — Class 1 (See Item 5) http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-B-2042&ccnshorttitle=Through-penetration+Firestop+S... 1/3 10/10/2014 r%rr%I I 20 Is /ICES 1. Floor Assembly — Min 6 in. (152 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* — Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. The devices are sized to accommodate the followinq nom pipe sizes: Nom Pipe Diam in. (mm) Firestop Device 1/2 to 1 (13 to 25) OPS-PL-0100 1-1/4 to 2 (32 to 51 OPS-PL-0200 2-1/2 to 3 (64 to 76) OPS-PL-0300 3 to 4 76 to 102) OPS-PL-0400 5 to 6 (127 to 152) OPS-PL-0600 SECURUS INC, DBA HOLDRITE — HydroFlame OPS-PL 3. Through Penetrant — One nonmetallic pipe or conduit to be installed within the firestop device. Pipe or conduit to be installed in accordance with firestop device installation instructions and rigidly supported on both sides of floor assembly. The following types of pipe, conduit or tubing may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. When nom 5 in. or 6 in. (127 or 152 mm) diam PVC pipe is used, F Rating is 2 hr and T Rating is 0 hr. When max 4 in. (102 mm) diam PVC pipe is used, F Rating is 3 hr and T Rating is 3 hr. B. Rigid Nonmetallic Conduit+ — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code (NFPA No. 70). When nom 5 in. or 6 in. (127 or 152 mm) diam PVC conduit is used, F Rating is 2 hr and T Rating is 0 hr. When max 4 in. (102 mm) diam PVC conduit is used, F Rating is 3 hr and T Rating is 3 hr. C. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 6 in. (152 mm) diam (or smaller) SDR 13.5 (or heavier) or Schedule 40 CPVC pipe for use in closed (process or supply) piping http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-B-2042&ccnshorttitle=Through-penetration+Firestop+S... 2/3 10/10/2014 y `, .1,21,2 TTgrq�.l@k�-p ra ' r,��tzp p s R E S U B s stems. W e o i r 6 111T. (1�\7/�br�i r�rl/ i e is used F��,ti 2jOZO hr and T Rating is 0 hr. When max 4 in. (102 mm) diam CPVC pipe is used, F �t�n i g hr and T Rating is 3 hr. CITY OF EDMONDS DEVELOPMENT SERVICES D. ACrylonitrile Butadiene Styrene (ABS) Pipe — Nom 4 In. (102 mm) diam (or smafl&R RTMENT Schedule 40 solid or cellular core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. When max 4 in. (102 mm) diam ABS pipe is used, F Rating is 3 hr and T Rating is 3 hr. E. Cross -Linked Polyethylene (PEX) Tubing — Nom 2 in. (51 mm) diam (or smaller) SDR 9 PEX tubing for use in closed (process or supply) piping systems. When max 2 in. (51 mm) diam ABS pipe is used, F Rating is 3 hr and T Rating is 3 hr. 4. Packing Material — Min 2 in. (51 mm) depth of min 4 pcf (64 kg/m3) mineral wool batt insulation tightly -packed into annular space with its top surface flush with the top surface of the floor. When optional sealant (Item 5) is used, top surface of packing material to be recessed min 1/4 in. (6mm) from top surface of floor. 5. Fill, Void or Cavity Material* - Sealant — (Optional, Not Shown) - Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Sealant to lap min 1/2 in. (13 mm) onto top surface of concrete around perimeter of firestop device. W Rating applies only when sealant is used. 3M COMPANY 3M FIRE PROTECTION PRODUCTS — FB-1000 NS, FB-3000 WT or FB-1003 SL * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. +Bearing the UL Listing Mark Last Updated on 2011-06-14 Questions? Print this page Terms of Use Page Too ©2014ULLLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2014 UL LLC". http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-B-2042&ccnshorttitle=Through-penetration+Firestop+S... 3/3 10/10/2014 H i V 3 TT�rq�.ltp�ra�er}Fir,� F—hems RES U B nL1IILIC r_C0TIC10ATInwc n10CrhTA12V rL��N� JLCC�/CJ Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT System No. F-A-5043 XH EZ. F-A-5043 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems System No. F-A-5043 July 30, 2010 F Rating — 2 Hr T Rating — 1-1/2 Hr http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-A-5043&ccnshorttitle=Through-penetration+Firestop+S... 1/3 10/10/2014 H Y NT TT�rq}�tp�ra�er}Fir,��t tems R E S U B r L/��N� J L C C �/ E.� Dec 11 2020 s 'ICES 1. Floor Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* — Sleeve — Max 8 in. (203 mm) diam cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. SECURUS INC, DBA HOLDRITE — HydroFlame WD Sleeve When HydroFlame WD 0600 Sleeve is used, the nominal 1 by 0.3 in. (25 by 7.6 mm) void created by the stepped base within the sleeve shall be tightly -packed with mineral wool batt insulation (Item 4) during firestop installation if concrete floor assembly is less than 7 in. thick. 3. Through -Penetrant — One metallic pipe or tubing to be centered within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor assembly. The following types of pipe or tubing may be used: A. Steel Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type M (or heavier) copper tubing. 4. Pipe Covering* — Max 1-1/2 in. (38 mm) thick hollow cylindrical heavy density mineral fiber units with an all service jacket. Longitudinal joints sealed with metal fasteners or factory -applied self-sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. A min annular space of 1/2 in. (13 mm) is required within the firestop system. See Pipe and Equipment Covering — Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. 5. Packing Material — Min 3-3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 6. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. When pipe covering (Item 4) thickness is greater than 1 in. (25 mm), the min thickness of sealant applied within the annulus shall be 1/2 in. (13 mm). 3M COMPANY 3M FIRE PROTECTION PRODUCTS — FB-3000 WT http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-A-5043&ccnshorttitle=Through-penetration+Firestop+S... 2/3 XHEZ.F-B-1017 - Through -penetration Firestop Systems RESP�1 of 3 HYDROFLAME SLEEVES Dec 11 2020 CITY OF EDMONDS ONLINE CERTIFICATIONS DIRECTORY DEVELOPMENTSERVICES �o Page Bottom XHEZ.F-B-1017 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through -penetration Firestop Systems See General Information for Through -penetration Firestop Systems System No. F-B-1017 November 20, 2009 F Rating — 3 Hr T Rating — 0 Hr W Rating — Class I (See Item 5) http://database.ul.com/cgi-binIXYVItemplatelLISEXT/I FRAMElshowpage.html?name=XHE... 7/7/2010 XHEZ.F-B-1017 - Through -penetration Firestop Systems HYDROFLAME SLEEVES RE SPIU$2 of 3 Dec 11 2020 CITY OF EDMONDS SERVICES ENT 1. Floor Assembly — Min 6 in. (152 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* — Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. SECURUS INC, DBA HUBBARD ENTERPRISES, DBA HOLDRITE - HYDROFLAME — HydroFlame SS -MT 3. Through Penetrant — One metallic pipe, conduit or tubing to be installed within the Firestop device. Pipe, conduit or tubing to be installed in accordance with firestop device installation instructions and rigidly supported on both sides of floor assembly. The following types of pipe, conduit or tubing may be used: A. Steel Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe — Nom 6 in. (152 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit — Nom 6 in. (152 mm) diam (or smaller) rigid steel conduit or nom 4 in. (102 mm) diam steel electrical metallic tubing. D. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. 4. Packing Material — (Optional. Not Shown) - Min 2 in. (51 mm) depth of min 4 pcf (64 kg/m3) mineral wool batt insulation tightly -packed into annular space between penetrant and device with its top surface flush with the top surface of the floor. When optional sealant (Item 5) is used, top surface of packing material to be recessed min 1/4 in. (6 mm) from top surface of floor. W Rating applies only when packing material and sealant (Item 5) is used. 5. Fill, Void or Cavity Material* - Sealant — (Optional, Not Shown) - Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Sealant to lap min 1/2 in. (13 mm) onto top surface of concrete around perimeter of firestop device. W Rating applies only when packing material (Item 4) and sealant is used. http://database.ul.com/cgi-binIXYVItemplatelLISEXT/I FRAMElshowpage.html?name=XHE... 7/7/2010 XHEZ.F-B-1017 - Through -penetration Firestop Systems RESP�3 of 3 HYDROFLAME SLEEVES Dec 11 2020 3M COMPANY DE EI O MF NDTSOERDVCES DEPARTMENT 3M FIRE PROTECTION PRODUCTS — FB-1000 INS, FB-3000 WT or FB-1003 SL *Bearing the UL Classification Mark Last Uodated on 2009-11-20 Questions? Print this page Notice of Disclaimer Page Too Copyright n 2010 Underwriters Laboratories Inc.(& The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2010 Underwriters Laboratories Inc.@" An Independent ❑rganlzatlon working for a safer world wlth integrity, precision and knowledge. lRl All .rH1P� 160MAPt021 http://database.ul.com/cgi-binIXYVItemplatelLISEXT/I FRAMElshowpage.html?name=XHE... 7/7/2010 10/10/2014 H i V rt TT�rq�.ltp�ra�er}Fir,� F_ttems RES U B nL1IILIC r_C0TIC10ATInwc n10CI±TA12V �I\/I JLCC�/CJ Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT System No. F-A-0026 XH EZ. F-A-0026 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems System No. F-A-0026 July 22, 2010 F Rating — 2 Hr T Rating —2 Hr L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400 F — 2 CFM/sq ft W Rating — Class 1 http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-A-0026&ccnshorttitle=Through-penetration+Firestop+S... 1/3 10/10/2014 HYMUrE TTKglltsra�}Fir, F— stems RESUB 1111 1MU111 1111 llllllllillllllXYlll lllllll�lllllillYll� lllll�lllllllllllll lllllllllllllllllllll � 11�lXlllllllllllltilll llllllll�llllllllllll Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT r 1. Floor Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* — Sleeve — Max 6 in. (152 mm) cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. SECURUS INC, DBA HOLDRITE — HydroFlame WD Sleeve When HydroFlame WD 0600 Sleeve is used, the nominal 1 by 0.3 in. (25 by 7.6 mm) void created by the stepped base within the sleeve shall be tightly -packed with mineral wool batt insulation (Item 4) during firestop installation if concrete floor assembly is less than 7 in. thick. 3. Packing Material — Min 3-3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into firestop device as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 4. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Sealant must lap onto top surface of concrete floor around entire perimeter of firestop device to attain W Rating. 3M COMPANY 3M FIRE PROTECTION PRODUCTS — FB-1000 NS or FB-1003SL * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 2010-07-22 ©2014ULLLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-A-0026&ccnshorttitle=Through-penetration+Firestop+S... 2/3 10/19/2016 HYE)VV1 frTl�rgWrtpe�tLiq_Vy9ms RESUB LJ f[ L/`��N� C J L C Dec 11 2002EE0 CITY OF EDON MDSN U DEVELOPMENT SERVICES DEPARTMENT Page Bottom System No. F-A-1133 XHEZ.F-A-1133 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems XHEZ7 - Through -penetration Firestop Systems Certified for Canada See General Information for Through -penetration Firestop Systems See General Information for Through -penetration Firestop Systems Certified for Canada System No. F-A-1133 September 12, 2016 ANSI/UL1479 (ASTM ll CAN/ULC S115 F Ratings — 2 and 3 Hr (See Item 6) F Ratings — 2 and 3 Hr (See Item 6) T Rating — 0 Hr FT Rating — 0 Hr L Rating At Ambient — Less Than 1 CFM/sq ft FH Rating — 3 Hr L Rating At 400 F — Less Than 1 CFM/sq ft FTH Rating — 0 Hr W Rating — Class 1 (See Item 5) L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400 F — Less Than 1 CFM/sq ft http://database.ul.com/cgi-bi n/XYV/tem pl ate/LISEXT/1 FRAM E/showpage.htm I?nam e=XH EZ. F-A-1133&ccnshorftitie=Through-penetration+Firestop+Systems... 1/4 10/19/2016 HYE)VV I LAM9rip_My9ms RES U B Dec 11 �0 0 � CITY OF EDM DEVELOPMENT SERVICES r DEPARTMENT Configuration A Configuration B System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly — The fire -rated concrete and fluted steel deck floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as http://database.ul.com/cgi-bi n/XYV/tem pl ate/LISEXT/1 FRAM E/showpage.htm I?nam e=XH EZ. F-A-1133&ccnshorftitie=Through-penetration+Fi restop+Systems... 2/4 10/19/2016 H Y E)V0'r'E rTMrtpe9Liq_ Vy9ms R E S U B over top of device base. Dec 11 2002EE0 CITY OF EDON MDSN U DEVELOPMENT SERVICES DEPARTMENT B. Steel Floor and Form Units* - Composite or noncomposite nom 3 in. (76 mm) deep fluted galv units as specified in the individual Floor -Ceiling design. Diam of opening cut through fluted floor unit to be maximum 1/4 in. (6 mm) larger than outside diameter of bottom extension portion of firestop device base. 1A. Floor Assembly - Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight 100-150 pcf (1600-2400 kg/m3) concrete. Measured over the top of the device base. Configuration A 2. Firestop Device* - Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. A HFP devices and optional accessories (not shown) includes sleeve extension, water module, deck adapter, aerator adapter and/or water dam installed in accordance with installation instructions. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. Firestop Devices for Firestop Devices for Fluted Deck (mm) Concrete Slab (Not Shown) 1/2 to 1 (13 to 25) HFP-M1, HFP-M1B, HFP-P1, add HFPCDI HFP-P1B 1-1/4 to 2 (32 to HF-M2, HFP-M2B, HFP-P2, add HFPCD2 51) HFP-P2B 2 to 3 (51 to 76) HFP-M3, HFP-M3B, HFP-P3, add HFPCD3 HFP-P3B 3 to 4 (76 to 102) HFP-M4, HFP-M4B, HFP-P4, add HFPCD4 HFP- P4B 5 to 6 (127 to 152) HFP-M6, HFP-M6B, HFP-P6, add HFPCD6 HFP-P6B SECURUS INC, DBA HOLDRITE - HydroFlame HFP-Mx, HFP-MxB, HFP-Px HFP-PxB Configuration B 2. Firestop Device* - Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. Optional accessory (not shown) aerator adapter installed in accordance with the installation instructions. The devices are sized to accommodate the followinq nom pipe sizes Nom Pipe Diam Firestop Devices for Concrete Firestop Devices for Fluted in. (mm) Slab Deck (Not Shown) 1/2 to 1 (13 to CD-PL-0100, CD-OPS-PL-0100, WD-PL-0100, OPS-PL-0100, OPS- 25) CD-OPS-MT-0100 MT-0100 1-1/4 to 2 (32 to CD-PL-0200, CD-OPS-PL-0200, WD-PL-0200, OPS-PL-0200, OPS- 51) CD-OPS-MT-0200 MT-0200 2 to 3 (51 to 76) CD-PL-0300, CD-OPS-PL-0300, WD-PL-0300, OPS-PL-0300, OPS- CD-OPS-MT-0300 MT-0300 3 to 4 (76 to 102) CD-PL-0400, CD-OPS-PL-0400, WD-PL-0400, OPS-PL-0400, OPS- CD-OPS-MT-0400 MT-0400 5 to 6 (127 to CD-PL-0600, CD-OPS-PL-0600, WD-PL-0600, OPS-PL-0600, OPS- 152) CD-OPS-MT-0600 MT-0600 SECURUS INC, DBA HOLDRITE - HydroFlame CD-OPS-MT, CD-PL, CD-OPS-PL,WD-PL, OPS-PL, OPS-MT 3. Through Penetrant - One metallic pipe, conduit or tubing to be installed within the firestop device. Pipe, conduit or tubing to be installed in accordance with firestop device installation instructions and rigidly supported on both sides of floor assembly. The following types of pipe, conduit or tubing may be used: A. Steel Pipe - Nom 6 in. (152 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 6 in. (152 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) rigid steel conduit or nom 4 in. (102 mm) diam steel electrical metallic tubing. http://database.ul.com/cgi-bi n/XYV/tem pl ate/LISEXT/1 FRAM E/showpage.htm I?nam e=XH EZ. F-A-1133&ccnshorftitie=Through-penetration+Firestop+Systems... 3/4 10/19/2016 H Y �—,)V0'rf rTi�ryy�rtpe�tLiq_ Vy9ms R E S U B �LJJ [ LL/yIVI C J L C Dec 11 2002EE0 CITY OF EDON MDSN U DEVELOPMENT SERVICES DEPARTMENT 4. Packing Material — (Optional. Not Shown) — Min 2 in. (51 mm) depth of min 4 pcf (64 kg/m3) mineral wool batt insulation tightly -packed into annular space between penetrant and device, flush with the top surface of the floor. When optional sealant (Item 5) is used, top surface of packing material to be recessed min 1/4 in. (6 mm) from top surface of floor. 4A. Packing Material — (Optional instead of 4, Not Shown) — Foam backer rod firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 5. Fill, Void or Cavity Material* — Sealant — (Optional, Not Shown) — Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Conf B (Only), Sealant to lap min 1/2 in. (13 mm) onto top surface of concrete around perimeter of firestop device. As an alternate 100% silicone sealant can be used. For Configuration B, The L Rating and W Rating applies only when packing material (Item 4) and sealant (Item 5) is used. 3M COMPANY 3M FIRE PROTECTION PRODUCTS — FB-1000 INS, FB-3000 WT or FB-1003 SL RECTORSEAL — Metacaulk 835+ or Biotherm 100 or 200 6. Pipe Tee Fitting System — (Optional, Not Shown) — For use with Iron Pipe (Item 313) only, One nom 6 in. (152 mm) diam (or smaller) PVC TESTRITE TEE Fitting (matched to penetrant diameter). The PVC TESTRITE TEE Fitting is secured to metallic penetrant (Item 313) with compression type pipe coupling elastomeric gasket with stainless steel jacket and stainless steel band clamps for use in vented (drain, waste or vent) iron pipe systems. Installed (Item 36) penetrant shall extend a minimum of 6 in. (152 mm) above the surface of the floor and minimum 12 in. (302 mm) below the bottom surface of the floor above assembly. When Item 6 is used within 24 in. (610 mm) of the device (Item 2) the F rating is limited to 2 Hours. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 2016-09-12 Questions? Print this page Terms of Use Page Top © 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2016 UL LLC". http://database.ul.com/cgi-bi n/XYV/tem pl ate/LISEXT/1 FRAM E/showpage.htm I?nam e=XH EZ. F-A-1133&ccnshorftitie=Through-penetration+Fi restop+Systems... 4/4 10/10/2014 Hy (JrC TT�rq�.ltp�ra�er}Fir,� F_ttems RES U B nwllur 011 ICIOATlnwc n1011TA12Y �I\/I JLCC�/CJ Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT System No. F-A-1109 XH EZ. F-A-1109 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems System No. F-A-1109 August 19, 2009 F Rating — 3 Hr T Rating — 0 Hr L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400 F — Less Than 1 CFM/sq ft W Rating — Class 1 http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-A-1109&ccnshorttitle=Through-penetration+Firestop+S... 1/3 10/10/2014 IUD ff1%rr% 2020 )MONDS T SERVICES MENT 1. Floor Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete floor. 2. Firestop Device* — Cast -in -place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. SECURUS INC, DBA HOLDRITE — HydroFlame PS-CF 3. Waste Pipe — One nom 3 in. (76 mm) or 4 in. (102 mm) diam cast iron pipe to be installed within the firestop device. Pipe to be installed approximately flush with top surface of floor in accordance with firestop device installation instructions and to be rigidly supported on underside of floor assembly. 4. Toilet Flange — Cast iron toilet flange with nominal 7 in. (178 mm) diam top ring and with nominal 4 in. (102 mm) OD throat sized to fit both 3 in. (76 mm) and 4 in. (102 mm) diam drain piping. Toilet flange secured inside metallic pipe (Item 3) and secured to top surface of floor with closet bolts. 5. Water Closet — Floor mounted vitreous china water closet. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 2009-08-19 Questions? Print this nacre Terms of Use Page Ton ©2014ULLLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2014 UL LLC". http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-A-1109&ccnshorttitle=Through-penetration+Firestop+S... 2/3 XHEZ.F-A-2189 - Through -penetration Firestop Systems RESP�1 of 3 HYDROFLAME SLEEVES Dec 11 2020 CITY OF EDMONDS ONLINE CERTIFICATIONS DIRECTORY DEVELOPMENTSERVICES �o Page Bottom XHEZ.F-A-2189 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through -penetration Firestop Systems See General Information for Through -penetration Firestop Systems System No. F-A-2189 November 20, 2009 F Rating — 3 Hr T Rating — 3 Hr L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400 F — Less Than 1 CFM/sq ft W Rating — Class i http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=XHE... 7/7/2010 XHEZ.F-A-2189 - Through -penetration Firestop Systems HYDROFLAME SLEEVES RE SPIU$2 of 3 Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES nFPARTMFNT 1. Floor Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete floor. 2. Firestop Device* — Cast -in -place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. SECURUS INC, DBA HUBBARD ENTERPRISES, DBA HOLDRITE - HYDROFLAME — HydroFlame PS-CF 3. Nonmetallic Pipe — One nonmetallic pipe to be installed within the firestop device. Pipe to be installed approximately flush with top surface of floor in accordance with Firestop device installation instructions and to be rigidly supported on underside of floor assembly. The following types of pipe may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 3 in. (76 mm) or 4 in. (102 mm) diam Schedule 40 solid or cellular core PVC pipe. B. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 3 in. (76 mm) or 4 in. (102 mm) diam Schedule 40 solid or cellular core ABS pipe. 4. Toilet Flange — PVC or ABS toilet flange with nominal 7 in. (178 mm) diam top ring and with nominal 4 in. (102 mm) OD throat sized to fit both 3 in. (76 mm) and 4 in. (102 mm) diam drain piping. Toilet flange cemented to top of nonmetallic pipe (Item 3) and secured to top surface of floor with closet bolts. 5. Water Closet — Floor mounted vitreous china water closet. *Bearing the UL Classification Mark Last Updated on 2009-11-20 Ouestions? Print this page Notice of Disclaimer Paae Top http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=XHE... 7/7/2010 XHEZ.F-A-1103 - Through -penetration Firestop Systems RESP�1 of 3 HYDROFLAME SLEEVES Dec 11 2020 CITY OF EDMONDS ONLINE CERTIFICATIONS DIRECTORY DEVELOPMENTSERVICES �o Page Bottom XHEZ.F-A-1103 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through -penetration Firestop Systems See General Information for Through -penetration Firestop Systems System No. F-A-1103 November 20, 2009 F Rating — 2 Hr T Rating — 3/4 Hr L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400°F — Less Than 1 CFM/sq ft W Rating — Class i http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=XHE... 7/7/2010 XHEZ.F-A-1103 - Through -penetration Firestop Systems HYDROFLAME SLEEVES RE SPIU$2 of 3 I� Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. Floor Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* - Tub Box — Nom 12-1/2 in. (318 mm) long by 2 in. (51 mm) deep nonmetallic tub box with adjustable legs and intumescent coupling. Cast in place firestop device attached to form and permanently embedded during concrete placement or grouted in concrete assembly in accordance with accompanying installation instructions. Min concrete thickness of 2 in. (51 mm) shall be maintained below tub box. SECURUS INC, DBA HUBBARD ENTERPRISES, DBA HOLDRITE - HYDROFLAME — HydroFlame PS-TB-200 3. Waste/Overflow Fitting — Nom 1-1/2 in. (38 mm) diam brass waste/overflow fitting with chromed brass drain tube inserted through base of tub box. Drain tube of waste/overflow fitting secured in top or bottom of tub box base using drain seal bushing supplied with firestop device. 4. Drain Piping — Nom 1-1/2 in. (38 mm) or 2 in. (51 mm) diam cast iron or copper drain piping with the appropriate fittings/bushings for connection to the waste/overflow fitting. Drain piping rigidly supported away from tub box with suitable hangers. *Bearing the UL Classification Mark Last Updated on 2009-11-20 Ouestions? Print this page Notice of Disclaimer Page Top Copyright n 2010 Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=XHE... 7/7/2010 XHEZ.F-B- 10 18 - Through -penetration Firestop Systems RESP�1 of 3 HYDROFLAME SLEEVES Dec 11 2020 CITY OF EDMONDS ONLINE CERTIFICATIONS DIRECTORY DEVELOPMENTSERVICES �o Page Bottom XHEZ.F-B-1018 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Through -penetration Firestop Systems See General Information for Through -penetration Firestop Systems System No. F-B-1018 November 20, 2009 F Rating — 3 Hr T Rating — 2 Hr L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400OF - Less Than 1 CFM/sq ft W Rating — Class i http://database.ul.com/cgi-binIXYVItemplatelLISEXT/I FRAMElshowpage.html?name=XHE... 7/7/2010 XHEZ.F-B- 10 18 - Through -penetration Firestop Systems HYDROFLAME SLEEVES RE SPIU$2 of 3 Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. Floor Assembly — Min 7 in. (178 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* - Tub Box — Nom 12-1/2 in. (318 mm) long by 2 in. (51 mm) deep nonmetallic tub box with adjustable legs and intumescent coupling. Cast in place firestop device attached to form and permanently embedded during concrete placement or grouted in concrete assembly in accordance with accompanying installation instructions. Min concrete thickness of 4-1/2 in. (51 mm) shall be maintained below tub box. SECURUS INC, DBA HUBBARD ENTERPRISES, DBA HOLDRITE - HYDROFLAME — HydroFlame TBS-TW-0150 3. Waste/Overflow Fitting — Nom 1-1/2 in. (38 mm) diam brass waste/overflow fitting with chromed brass drain tube inserted through base of tub box. Drain tube of waste/overflow fitting secured in top of tub box using drain seal bushing supplied with firestop device. 4. Drain Piping — Nom 1-1/2 in. (38 mm) or 2 in. (51 mm) diam cast iron or copper drain piping with the appropriate fittings/bushings for connection to the waste/overflow fitting. Drain piping rigidly supported away from tub box with suitable hangers. *Bearing the UL Classification Mark Last Updated on 2009-11-20 Ouestions? Print this page Notice of Disclaimer Page Top Copyright n 2010 Underwriters Laboratories Inc.@ The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. http://database.ul.com/cgi-binIXYVItemplatelLISEXT/I FRAMElshowpage.html?name=XHE... 7/7/2010 HYDROFLAME SLEEVES RESUB Dec 11 2020 Page Bottom CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT System No. F-A-2183 XHEZ.F-A-2183 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered Certified. Through -penetration Firestop Systems See General Information forThrough-penetration Firestop Systems System No. F-A-2183 August 19, 2009 F Rating — 2 Hr T Rating — 3/4 Hr L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400OF — Less Than 1 CFM/sq ft W Rating — Class 1 HYDR FLAME SLEEVES RESUB Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. Floor Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* - Tub Box — Nom 12-1/2 in. (318 mm) long by 2 in. (51 mm) deep nonmetallic tub box with adjustable legs and intumescent coupling. Cast in place firestop device attached to form and permanently embedded during concrete placement or grouted in concrete assembly in accordance with accompanying installation instructions. Min concrete thickness of 2 in. (51 mm) shall be maintained below tub box. SECURUS INC, DBA HOLDRITE — Hydro Flame PS-TB-200 3. Waste/Overflow Fitting — Nom 1-1/2 in. (38 mm) diam Schedule 40 polyvinyl chloride (PVC) waste/overflow fitting and drain pipe cemented together and inserted through base of tub box. Drain pipe of waste/overflow fitting secured in top or bottom of tub box base using drain seal bushing supplied with firestop device. 3A. Alternate Waste/Overflow Fitting — (Not Shown) - Nom 1-1/2 in. (38 mm) diam thin -wall PVC waste/overflow fitting and drain tube inserted in and secured to top of tub box base using drain seal bushing supplied with firestop device. 4. Drain Piping — Nom 1-1/2 in. (38 mm) or 2 in. (51 mm) diam Schedule 40 PVC, Schedule 40 ABS, cast iron or copper drain piping with the appropriate fittings/bushings for connection to the waste/overflow fitting. When alternate thin -wall PVC waste/overflow fitting (Item 3A) is used, nom 2 in. (51 mm) diam PVC pipe cemented into bottom of tub box base for connection to P-trap. Drain piping rigidly supported away from tub box with suitable hangers. *Bearing the UL Classification Mark Last Updated on 2009-08-19 Questions? Print this page Terms of Use Page Top ©2014 ULLLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and 10/10/2014 H i (Jr f TTK1tp�ra�er}Fir,� F_ttems RESU B nL1IILIC r_C0TIC10ATInwc n10CrhTA12V JLCC�/CJ Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT System No. F-B-2043 XHEZ.F-B-2043 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems System No. F-B-2043 August 19, 2009 F Rating — 3 Hr T Rating — 2 Hr L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400OF - Less Than 1 CFM/sq ft W Rating — Class 1 http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-B-2043&ccnshorttitle=Through-penetration+Firestop+S... 1/3 10/10/2014 HY �rgl.l�p�ra�er}Fir,��,tpq�stems RESUB 1 �a .F�`*'� '}�1 Imo..• *� n Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. Floor Assembly — Min 7 in. (179 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. 2. Firestop Device* - Tub Box — Nom 12-1/2 in. (318 mm) long by 2 in. (51 mm) deep nonmetallic tub box with adjustable legs and intumescent coupling. Cast in place firestop device attached to form and permanently embedded during concrete placement or grouted in concrete assembly in accordance with accompanying installation instructions. Min concrete thickness of 4-1/2 in. (51 mm) shall be maintained below tub box. SECURUS INC, DBA HOLDRITE — HydroFlame TBS-TW-0150, HydroFlame TBS-NP-0150 3. Waste/Overflow Fitting — Nom 1-1/2 in. (38 mm) diam thin -wall PVC waste/overflow fitting and drain tube inserted in and secured to top of tub box base using drain seal bushing supplied with Firestop device. 3A. Alternate Waste/Overflow Fitting — (Not Shown) - Nom 1-1/2 in. (38 mm) diam Schedule 40 polyvinyl chloride (PVC) waste/overflow fitting and drain pipe cemented together and inserted through base of tub box. 4. Drain Piping — Nom 1-1/2 in. (38 mm) or 2 in. (51 mm) diam Schedule 40 PVC, Schedule 40 ABS, cast iron or copper drain piping with the appropriate fittings/bushings for connection to the waste/overflow fitting. Drain piping rigidly supported away from tub box with suitable hangers. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 2009-08-19 ©2014ULLLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory http://database.u1.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=XHEZ.F-B-2043&ccnshorttitle=Through-penetration+Firestop+S... 2/3 HYDROFLAME SLEEVES RESUB System No. F-A-2190 XH EZ. F-A-2190 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Page Bottom • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems XHEZ7 - Through -penetration Firestop Systems Certified for Canada See General Information for Through -penetration Firestop Systems See General Information for Through -penetration Firestop Systems Certified for Canada System No. F-A-2190 February 01, 2017 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating — 3 Hr F Rating — 3 Hr T Rating — 0 Hr FT Rating — 0 Hr FH Rating — 3 Hr FTH Rating — 0 Hr HYDROFLAME SLEEVES RESUB Dec 11 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Configuration A Configuration B System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. HYDROFLAME SLEEVES RESUB 1. Floor Assembly — Min 5 in. (127 mm) thick lightweight or normal weight (100-150 pcf oa%@0114?0RQ/m3) concrete floor assembly. CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Configuration A 2. Firestop Device* — Shower/Floor Drain — Cast in place firestop device with polished brass or chromed steel shower drain or floor drain strainer attached to form and permanently embedded during concrete placement or grouted in concrete assembly in accordance with accompanying installation instructions. For HFP devices optional accessory (not shown) includes sleeve extension installed in accordance with installation instructions. SECURUS INC, DBA HOLDRITE — HydroFlame, HFP-SH2-DRN 3. Drain Piping — Nom 1-1/2 to 2 in. (38 to 51 mm) diam Schedule 40 PVC or Schedule 40 ABS drain piping cemented, threaded or push type gasket into bottom socket of Shower/Floor Drain fitting. Different drain pipe types (cast iron, ABS, copper, etc.) may also be connected to the shower drain pipe by extending drain pipe min 2 inches (51 mm) below the floor and then using the appropriate fittings/bushings/compression fittings to adapt to these different types of drain pipe. Drain piping rigidly supported at underside of floor with suitable hangers. Configuration B 2. Firestop Device* - Shower/Floor Drain — Cast in place firestop device with polished brass or chromed steel shower drain or floor drain strainer attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. SECURUS INC, DBA HOLDRITE — HydroFlame PS-SD-0200 3. Drain Piping — Nom 2 in. (51 mm) diam Schedule 40 PVC or Schedule 40 ABS drain piping cemented into bottom socket of firestop device. Different drain pipe types (cast iron, ABS, copper, etc.) can be connected to the shower drain base by cementing a short piece of PVC pipe into the bottom of the shower drain base so it extends min 2 in. (51 mm) below the floor and then using the appropriate fittings/bushings to adapt to these types of drain pipe. When the tail piece of the shower drain assembly extends below the slab, cement or compression fittings/bushings can be used to adapt to the different drain pipe types. Drain piping rigidly supported at underside of floor with suitable hangers. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 2017-02-01 Questions? Print this page Terms of Use Page Top ©2017ULLLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2017 UL LLC". 10/19/2016 H Y EM0'Ft AMtpe9 t F_t S 8m s R E S U B J � Dec 11 2MM02EE0 CITY OF EDMONDSN U DEVELOPMENT SERVICES DEPARTMENT Page Bottom System No. F-A-1111 XHEZ.F-A-1111 Through -penetration Firestop Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through -penetration Firestop Systems XHEZ7 - Through -penetration Firestop Systems Certified for Canada See General Information for Through -penetration Firestop Systems See General Information for Through -penetration Firestop Systems Certified for Canada System No. F-A-1111 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 FRating —2Hr FRating —2Hr T Rating — 0 Hr FT Rating — 0 Hr FH Rating — 2 Hr FTH Rating — 0 Hr http://database.ul.com/cgi-bi n/XYV/tem pl ate/LISEXT/1 FRAM E/showpage.htm I?name=XH EZ. F-A-1111 &ccnshorftitle=Through-penetration+Firestop+Systems&... 1/3 10/19/2016 H Y EMb'Ft AID- tpe9 ti F-t 8m s R E S U B Dec 11 Equ CITY OF ED DEVELOPMENT SERVICES DEPARTMENT Configuration A Configuration B http://database.ul.com/cgi-bi n/XYV/tem pl ate/LISEXT/1 FRAM E/showpage.htm I?name=XH EZ. F-A-1111 &ccnshorftitle=Through-penetration+Fi restop+Systems&... 2/3 10/19/2016 H Y EM0'FtAMtpe9 t F_t S 8ms RESUB concrete floor assembly measured above the base of the device. Dec 11 2MM02EE0 CITY OF EDMONDSN U DEVELOPMENT SERVICES DEPARTMENT 1A. Floor Assembly — (Configuration A, Optional, Not Shown) — The fire rated unprotected concrete and steel floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight 100-150 pcf (1600-2400 kg/m3) concrete measured above the base of the device. B. Steel Floor and Form Units* — Composite or non -composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor -Ceiling Design. Configuration A 2. Firestop Device* — Shower/Floor Drain — Cast in place firestop device with cast iron drain body (Item 3) attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. For HFP devices the optional accessories (not shown) includes a sleeve extension, aerator adapter deck adapter, midbody seal and/or water module installed in accordance with installation instructions. Devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) Firestop Devices for Concrete Slab Firestop Devices for Fluted Deck (Not Shown) 1-1/2 to 2 (38 to 51) HFP-2CI-DRN add HFPCD2 2 to 3 (51 to 76) HFP-23CI-DRN add HFPCD3 3 to 4 (76 to 102) HFP-34CI-DRN add HFPCD4 5 to 6 (127 to 152) HFP-6CI-DRN add HFPCD6 SECURUS INC, DBA HOLDRITE — HFP-xCI-DRN 3. Floor Drain — Cast iron drain body secured in or on top of firestop device in accordance with accompanying installation instructions. 4. Drain Piping — Max nominal 6 in. (152 mm) diam cast iron drain piping threaded or push type gasket into cast iron drain body. Drain piping rigidly supported at underside of floor with suitable hangers. Configuration B 2. Firestop Device* — Shower/Floor Drain — Cast in place firestop device with cast iron drain body (Item 3) attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. Devices are sized to accommodate the following nom pipe sizes: SECURUS INC, DBA HOLDRITE — Type HM-CIDK 3. Floor Drain — Cast iron drain body secured in top socket of firestop device using stainless steel band clamp provided with Firestop device in accordance with manufactures instructions. 4. Drain Piping — Nom 2, 3, 4, 5 or 6 in. (51, 76, 102, 127 or 152 mm) diam cast iron drain piping threaded into cast iron drain body. Drain piping rigidly supported at underside of floor with suitable hangers. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 2016-09-12 Questions? Print this page Terms of Use Page Top © 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2016 UL LLC". http://database.ul.com/cgi-bi n/XYV/tem pl ate/LISEXT/1 FRAM E/showpage.htm I?name=XH EZ. F-A-1111 &ccnshorftitle=Through-penetration+Firestop+Systems&... 3/3