FIR2021-0035+Fire_Alarm_Equipment_Specification_Sheets+4.15.2021_1.17.52_PM+2147683
(E)POTTER The Symbol of Protection Features • One (1) Form C relay contact • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD 100-RM uses one (1) SLC loop address to provide one (1) Form C relay contact. The module mounts on either a 4" square or double gang box. The PAD 100-RM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD 100-RM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-RM is an interface module providing one (1) Form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD100-RM. The PAD 100-RM uses a single device address to identify relay contacts. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD 100-RM Relay Module -C MB/ + + f i2 NE J © POTfER FM ( U` APPROVED Technical Specifications Operating Voltage 24.OV Max SLC Standby 240µA Current Max SLC Alarm 240µA Current Relay Contacts 2A @30VDC, 0.5A @125VAC Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L X 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830084 - REV D 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Installation Using Compatible Electrical Box Fig 1 Wiring Diagram PAD] 00-RMRelay Circuit Fig 2 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE SYl4VHN O ® ,Y ONE (1)FORM C i RELAY CONTACTS o —NC M 0 0 0 0 o ®PO= o 0 PA IOPNM 0 PAD 100-RM Relay Module It is possible that the internal relay in the PAD100-RM may be shipped in the non -normal / activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description I Stock No. PAD100-RM Relay Module 13992705 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830084 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • One (1) Class B monitoring input • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty • UUKL Listed for Smoke Control NOTE: This addressable module does not support 2-wire smoke detectors. Description The PAD100-SIM uses one (1) SLC loop addresses when monitoring one (1) Class B circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring one (1) Class B circuit. The PAD100-SIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The PAD100-SIM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-SIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class B circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-SIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD 100-SIM Single Input Module P�SEMB��O i4, rHE J © POTrEIt ��U`<APP�ROV>ED FR.. Technical Specifications Operating Voltage 24.OV Max SLC Standby 240µA Current Max SLC Alarm 240µA Current Max Wiring Resistance 10012 of IDC Max Wiring INF Capacitance of IDC EOL Resistor 5.1K f2 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (I06mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830083 - REV D 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Installation Using Compatible Electrical Box Fig 1 K A Wiring Diagram PAD100-SIM With Class B Circuit Fig 2 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE END -OF -LINE RESISTOR 5.1KOHM % W Part #3005013 al Ordering Information Model Description Stock No. PAD100-SIM Single Input Module 3992704 PAD 100-SIM Single Input Module Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830083 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Single module with dual contact monitoring inputs • Two (2) Class B or one (1) Class A monitoring inputs • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty • UUKL Listed for Smoke Control NOTE: This addressable module does not support 2-wire smoke detectors. Description The PAD100-DIM uses one (1) SLC loop address when monitoring two (2) Class B circuits or one (1) Class A circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterflow and valve tamper switches when they are located in the same proximity. The PAD 100-DIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When an input is activated, the LED will flash at a fast rate. Application The PAD 100-DIM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-DIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring two separate Class B or one Class A circuits. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD100-DIM. When the PAD100- DIM is used to monitor two individual Class B circuits a single device address is assigned, each input is then identified as a sub -point of the module address. For example, if the address number is assigned as "8", the first input will be "8.1" and the second input will be "8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD100-DIM Dual Input Module ®? J ASEMB��O i2 PHE VIP F M Ok S APPROVED Technical Specifications Operating Voltage 24.OV Max SLC Standby 240µA Current Max SLC Alarm 240µA Current Max Wiring Resistance 10012 of IDC Max Wiring INF Capacitance of IDC EOL Resistor 5.lK f2 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (I06mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.61bs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082 - REV D • 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Installation Using Compatible Electrical Box Fig 1 Wiring Diagrams PAD100-DIM With One Class A Circuit Fig 2 0 FROM FACP OR PREVIOUS MODULE ® TO NEXT MODULE sLc }J ® ® 1 IN7 ® INP ® J®PM10Dg1 0 (:�D 0 G NOTE: END -OF -LINE RESISTOR IS NOT REQUIRED PAD100-DIM With Two Class B Circuits Fig 3 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE END -OF -LINE RESISTOR aa:[ 5.`IKOHM,�W Part #3005013 END -OF -LINE RESISTOR a:r:r[ 5.1KOHMY2W Part #3005013 Ordering Information Model Description Stock No. PAD100-DIM Dual Input Module 3992703 MOVE THE "CL-A" DIP SWITCH TO "UP" POSITION FOR CLASS A WIRING MOVE THE "CL-A" DIP SWITCH TO "DOWN"POSITION FOR CLASS B WIRING PAD100-DIM Dual Input Module Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082 - REV D 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Low profile, less than 2 inches with the base • Wide selectable sensitivity range of 1.0 to 3.7%/foot • Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple DIP switch address setting, no programming tool required • LED alarm indicator • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD 100-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD 100-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PAD100-PD features drift compensation and has built in dirty detector warning as well as. The PAD 100-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD100-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD100-PD Photoelectric Smoke Sensor QySEMB�SO • W R�yTHE VyP 4r O � FM =, U� APPROVED LISTED Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 µA Alarm indicator 1 LED Alarm set -point range 1.0 to 3.7 %/ft 3.6-12 %/m Installation temperature 32 to 120 ° F / 0 to 49 ° C range Operating relative 0% to 93% (Non -condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) 101g (3.56oz) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830108 - REV D • 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Air Velocity Ratings The PAD100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. PAD100-PD Photoelectric Smoke Sensor The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD100-PD will operate even though the LED may not illuminate. Operation The PAD 100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD 100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD 100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE. As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PAD100-6DB 6" Standard Base 3992732 PAD100-IB 6" base with an isolator module included. 3992730 PAD100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 3992728 PAD100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6" base with speaker included 3992762 Ordering Information Model Description I Stock No. PAD100-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830108 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Installation Manual: PAD100-MIM Micro Input Module NOTICE TO THE INSTALLER This manual provides an overview and the installation instructions for the PAD100-MIM module. This module is only compatible with addressable fire systems that utilize the PAD Addressable Protocol. All terminals are power limited and should be wired in accordance with the requirements of NFPA 70 (NEC) and NFPA 72 (National Fire Alarm Code). Failure to follow the wiring diagrams in the following pages will cause the system to not operate as intended. For further information, refer to the control panel installation instructions. The module shall only be installed with listed control panels. Refer to the control panel installation manual for proper system operation. 1. Description The PAD100-MIM is used to monitor the status of an initiating device(s) that contain a normally open set of dry contacts. The module is enclosed in a plastic case to protect against inadvertent shorts and ground faults. The case can be mounted using a single screw. Generally the PAD100-MIM is used to monitor pull stations and other devices where the module is installed in an electrical box or enclosure behind the device being monitored. The PAD100-MIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When an input is activated, the LED will flash at a fast rate. If the LED blink has been disabled via the programming software in a normal condition the LED of the device will be off. All other conditions remain the same. 2. Setting the Address All PAD protocol detectors and modules require an address prior to connection to the panel's SLC loop. Each PAD device's address (i.e., detector and/or module) is set by changing the dip switches located on the device. PAD device addresses are comprised of a seven (7) position dip switch used to program each device with an address ranging from 1-127. Figure 1. PAD Device Dip Switch Addresses Table (Addresses 1-127) 1 L 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 1 L 4 25 10 3L 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 1 L 4 0 10 5L 1 L 4 25 1 2 4 8 16 32 64 1 2 4 8 16 32 64 Note: Each "gray" box indicates that the dip switch is "On," and each "white" box indicates "Off." The examples shown below illustrate a PAD device's dip switch settings: the 1 st example shows a device not addressed where all dip switch settings are in the default "Off' position, the 2nd illustrates an addressed PAD device via the dip switch settings. Figure 2. Examples of PAD Device Showing Default Dip Switch Setting (Unaddressed) & Addressed PAD Device 1 2 4 8 16 32 64 1 2 4 8 16 32 64 AExample shows this PAD device's All dip switches are On shown in the "Off" On address = 42. Dip switches #2, 8 & Off position. Off 32 are in the "On" position. Potter Electric Signal Company, LLC St. Louis, MO Phone: (800) 325-3936 www.pottersignal.com Document 5406302-A 02/16 PAGE 1 OF 2 INSTALLATION MANUAL: PAD100-MIM MICRO INPUT MODULE Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the SLC or device. • Power to the SLC is removed. • Field wiring on module is correctly installed. • Field wiring has no open or short circuits. 3. Technical Specifications Operating Voltage 24.OV Max SLC Standby Current 200 p A Max SLC Alarm Current 200 N A IDC Input Circuit Class B Max Wiring Resistance of IDC 1000 Max Wiring Capacitance of IDC 1 pF Max IDC Voltage 2.05 VDC Max IDC Current 120 p A EOL Resistor 5.1 K 0 Operating Temperature Range 32 to 120 F (0 to 49 C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per Loop 127 units Dimensions 1.75" L x 1.36" W x 43" D Mounting Options 2-1/2" deep single -gang box Shipping Weight 0.3 Ibs 4. Wiring Diagram Below is an wiring diagram showing how to wire a PAD100-MIM module to the panel. Figure 3. Example of Wiring a PAD100-MIM FROM FACP OR PREVIOUS DEVICE AND TO NEXT DEV Notes: • SLC wiring style supports the Class A, Class B and Class X. • IDC wiring style is Class B. • SLC loop wiring (SLC+, SLC-) and initiating device wiring (IN) are power limited. • Wiring for terminals SLC+, SLC- are supervised. • Wiring for terminals (IN) are supervised. • This addressable module does not support 2-wire detectors. • All wiring is between #12 (max.) and #22 (min.). • Wire Preparation — Strip all wires 1/4 inch from their edges as shown here: 1/4 inch I-4 ►I — Stripping too much insulation may cause a ground fault. TO NORMALLY OPEN — Stripping too little may cause a poor connection and MONITORED DEVICE subsequently an open circuit. 5.1 K OHM REQUIRED Part #3005013 These instructions do not purport to cover all the details or variations in the equipment described, nor provide for every possible contingency to be met in connection with installation, operation and maintenance. Specifications subject to change without prior notification. For Technical Assistance contact Potter Electric Signal Company at 866-956-1211. Actual performance is based on proper application of the product by a qualified professional. Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser's purpose, the matter should be referred to a distributor in your region. Potter Electric Signal Company, LLC St. Louis, MO Phone: (800) 325-3936 www.pottersignal.com Document 5406302-A 02/16 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Single or Dual Action versions • Durable die-cast construction • Reset key matches the fire alarm control panels • Compatible with IPA Series panels • SLC Class A, Class X & Class B • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD100-PSSA (Single Action) is activated by simply pulling the white "T" bar handle down. The PAD100-PSDA (Dual Action) is activated by lifting the front cover and then pulling the white "T" bar handle down. Once activated, the "T" bar cannot be reset without opening the front cover. Opening the front cover will also activate the pull station. To reset the PAD 100-PS Series, use the Potter WS-93 key to unlock and open the front cover. Once the cover is open, push the "T" bar back into the normal position and re -secure the front cover. Application The PAD 1 00-PSSA/PSDA is compatible with Potter's IPA and AFC/ ARC series addressable fire alarm control panels. It is a non -coded addressable pull station available in either a single or dual action model and installs on a single gang box or surface mounts using the P32-BB or P32-DBB (deep) back box. PAD 100-PSSA/PS DA Addressable Pull Station Single/Dual Action �RO U`9�R . w<AP(� Technical Specifications Operating Voltage 24.0 VDC Max SLC Standby Current 200uA Max SLC Alarm Current 200uA 32°F - 120°F (0° - 49°C) Environmental Limitations Indoor Only Dimensions 4.75" H x 3.25" W x 1.75" D Relative Humidity Range 0 - 93% (non -condensing) Single gang box or Mounting Options Potter P32-BB/DBB APS-SA - 1.22 lbs. [ZppingWei t APS-DA - 1.46 lbs. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830097 - REV D • 12/18 PAGE 1 OF 2 PAD 100-PSSA/PSDA (E)POTTER Addressable Pull Station The Symbol of Protection Single/Dual Action Setting the Address The PAD 100-PS Series uses one SLC address assigned to the device. The address is set using the DIP switch located on the back of the PAD 100-PS device. Pull Station Front View Fig 1 o-_ Hn c jz p U ©PorTER PAD100-PSDA Pull Station Back View and Wiring Fig 2 FROM FACP OR PREVIOUS DEVICE TO NEXT DEVICE Ordering Information 0 Model Description Stock No. PAD100-PSSA Addressable Pull Station, Single Action 3992721 PAD100-PSDA Addressable Pull Station, Dual Action 3992720 U POTTER PAD 100-PSSA WIRED CONTACTS 0 0 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830097 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • 4,064 addresses available on this analog addressable system • Additional system capacity achieved via multi -point SLC modules • 1500 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built -In • System Operates as Class A or Class B for SLC, P-Link and NACs • 10 Amp Power Supply, Expandable to 315 amps • 6 NACS, Regulated, Rated at 3 Amps each, expandable to 192 • 4 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort • Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Cabinet will house up to 18 AH batteries • Optional two line DACT with UD-2000 that can report General, Zone or Point Information • Built in IP communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status, Reports and Event Information • Product includes 5 year warranty • UUKL Listed for Smoke Control Description The IPA4000 is an expandable analog/addressable releasing fire alarm system with a total system capacity of 4,064 addresses. Additional capacity on the system is achieved using multi -point SLC modules The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. The system is expandable with a total of thirty-one additional addressable Signaling Line Circuits (SLC) each with a maximum of 127 devices. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The IPA-4000 has a 10 Amp power supply with six Notification Appliance Circuits (NACs) and four Input/Output (1/0) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA4000 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the IPA4000 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six PAD100-SLCE SLC loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. IPA-4000 Fire Alarm Control Panel FM APPROVED Technical Specifications ge LISTED Dimensions 18 "/16"W x 27 s/16"H x 4 7/16"D AC Mains 5.0 Amps @ 120 VAC 50/60 HZ 3.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-220 mA • 10 Amps power for NACs, I/O, and P-Link Battey 3 Amps per NAC, regulated • 1 Amp per I/O circuit, regulated • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp Temperature and 320 to 1200 (0°C to 49°C) with a maximum Humidity Range humidity of 93% non -condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Standards Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pol), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 1 OF 4 (E)POTTER The Symbol of Protection IPA-4000 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 4,064 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD 100-PHD Combination Analog Photo Electric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135' Fahrenheit heat detector. PAD100-HD Analog Fixed Temperature Heat Detector that is selectable from 135' F to 185°F. PAD 100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD100-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD100-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD100-I13 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description PAD100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD 100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD 100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD 100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-IM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 100-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD100-OR0I One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 2 OF 4 (E)POTTER The Symbol of Protection SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps."Each loop is capable of 127 points, with a max wiring distance of 10,000 ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault - Amber • Supervisory - Amber • Silenced - Amber • Trouble - Amber • Pre -Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-4000 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PAD100-SLCE-Analog/Addressable loop expansion module (maximum of 31 per IPA-4000) IPA-4000 Fire Alarm Control Panel RA-6075R — 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) — 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) — 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) — 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the IPA-4000 as releasing circuits. CA-6500 — Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 — UL listed, Dual line telephone alarm communicator DRV 50 — LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 — Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 — Fiber interface module, used to extend P-Link to multi - mode fiber (2 required) RLY 5 — Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 — Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi -Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6 — Initiating device circuit provides 6 programmable inputs AE-2 — Two card expansion cabinet AE-8 — Eight card expansion cabinet AE-14 — Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-4000 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur -Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 3 OF 4 (E)POTTER The Symbol of Protection Dimensions 18.91 " 17.60" TOP o ° O Oo 0 0 0 0 N LEFT SIDE BOTTOM Ordering Information Model Description Stock No. IPA-4000 Fire Alarm Releasing Control Panel 3992717 Replacement Board IPA-4000 3992740 IPA-4000 Fire Alarm Control Panel 4.41" 3.75" DEPTH SIDE Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 73218BN4UNLVNOCI12CZ 73212BN4TNLVN0C322C2 Victaulic 753-E Series Mini Max MX123 & MX200 w/ 8876677 & 889323 Viking 11591, 11601, 11602, 13843, & 13844 TLX PA0036 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830102 - REV G • 1/20 PAGE 4 OF 4 (E)POTTER PAD100-HD The Symbol of Protection Heat Detector Features P�SEMB�Fo • Selectable Rate of Rise and/or Fixed Heat Detector �P i2 THE J`' • Low profile ■IC Qy • Reliable detection technology • LED Alarm Indicator • Ambient temperature listing of 32' F to 150' F • Simple DIP switch address setting, no programming tool required + l� • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD100-HD is a listed Analog Addressable rate of rise and/or fixed temperature heat sensor compatible with any fire alarm control panel that has the Potter Addressable Device (PAD) protocol. The heat sensing portion utilizes a proven thermistor for accurate and reliable heat detection. The sensor and base (not included) are made of a durable plastic in an off white to blend in with the ceiling. The PAD100-HD is UL listed with a selectable fixed temperature point from 135' to 185' Fahrenheit and can be used for rate of rise applications. See detector spacing limitations below. This flexibility allows the installer to cover a wide variety of applications with a single unit. The PAD100-HD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD 100-HD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. FM =, U� '� APPROVED LISTED Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 µA Alarm indicator 1 LED Alarm set -point range 135 to 185 'F/ 57 to 85 °C Rate of Rise Detection 150F/min. (8.3'C/min.) (Selectable Option) Installation temperature 32 to 150 OF / 0 to 66 °C range Operating relative 0% to 93% (Non -condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop Color Eggshell White Weight (without base) 82g (2.89 oz) Dimensions (without Height: 1.94 in (49mm) base) Diameter 3.93 in (100mm) Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830110 - REV E • 6/20 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Operation PAD100-HD Heat Detector The PAD 100-HD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LED flashes every time the unit is polled and will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD 100-HD with the PAD 100-4DB or PAD 100-6DB has a low profile to blend into the surrounding environment. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD100-HD will operate even though the LED will not illuminate. Spacing The ANSUUL listed spacing limitations of PAD 100-HD smooth ceiling are dependent on alarm set point. Alarm Set -Point Rate of Rise Spacing Fixed Temperature Spacing 135°F to 160°F Max. 70 ft. Max. 70 ft. (57°C to 71°C) 161°F to 1747 Max. 60 ft. Max. 60 ft. (72°C to 79°C) 175°F to 185°F I Max. 15 ft. I Max. 15 ft. (80°C to 85°C) Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PAD100-61)B 6" Standard Base 3992732 PAD100-I13 6" base with an isolator module included. 3992730 PAD100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 3992728 PAD100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6" base with speaker included 3992762 Ordering Information Model Description I Stock No. PAD100-HD Fixed Temperature Heat Sensor 3992735 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830110 - REV E • 6/20 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Detects smoke in building HVAC ducts • Ships complete with housing and head • Compatible with addressable IPA and AFC/ARC series panels • SLC in and out wire terminals • SLC Class A, Class X & Class B • Installation without removing the head • Listed Air Velocity of 100 to 4,000 ft/minute • No screens or filters in housing • Durable plastic enclosure and clear cover • Integrated cover tamper switch • Utilizes simple snap in sampling tubes STN series • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD100-DUCT is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke detectors. Air sampling is accomplished by two tubes which protrude into the duct. An exhaust tube of one standard length (7") is supplied in the installation kit with the smoke duct unit. Once the duct width has been determined the air intake sampling tubes must be ordered. Sampling tubes are supplied in three standard lengths: 2.5 ft., 5 ft., and 10 ft. and cut to size to fit the duct. Mounting the duct smoke unit is accomplished by the use of a template and 2 sheet metal screws, which are provided. Mounting can be achieved without the removal of the clear cover which is secured by 4 capture screws. Application The Potter Electric PAD100-DUCT duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in commercial, industrial and residential applications. The PAD 100-DUCT is compatible with the IPA and AFC/ARC series addressable fire alarm control panels. PAD100-DUCT Analog Addressable Duct Detector ItpSSEMB��O IHE 1 FM ( U` APPROVED Technical Specifications Duct Detector Model Number PAD100-DUCT Operating Voltage 24 VDC Current Draw 300 µA Detector Head Model PAD100-DD Detector Head Type Photoelectric Alarm Set Point Fixed at 2.5%/ft Sensitivity Test Method Self diagnostic test Air Velocity 100 to 4000 ft./min Ambient Temperature 320F to 120°F (0°C to 49°C) Humidity 10% to 85% Relative humidity (non - condensing) Housing Material Plastic backbox, clear plastic cover Finish Gray backbox with clear cover Dimensions 13 1/2"L x 4 1/2" W x 2 1/4" H Maximum Net Weight 2 lbs. Sampling Tubes 2.5 ft., 5 ft., or 10 ft. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830099 - REV E • 8/19 PAGE 1 OF 2 (E)POTTER PAD100-DUCT The Symbol of Protection Analog Addressable Duct Detector Engineering Specifications Air duct smoke detectors shall be Potter Electric PAD 100-DUCT Series. The detectors shall be listed by Underwriters Laboratories per UL 268A. The detectors shall operate at air velocities from 100 feet per minute to 4000 feet per minute. The duct detector housings shall be of plastic construction and complete mechanical installation may be performed without removal of detector cover. Visual indication of alarm and power must be provided on detector front. Detector heads shall not require additional filters or screens which must be maintained. The housing shall contain a detector base and PAD 100-DD duct smoke detector head. Terminal connections shall be of the screw type and be a minimum of # 12 screw. All wiring must comply with local codes and regulations. Detector shall use the STN series of sampling tubes. Wiring Diagram Fig 1 TO NEXT MODULE FROM FACP or PREVIOUS MODULE Ordering Information Model I Description I Stock No. PAD 100-DUCT IAnalog Addressable Duct Detector 3992713 Model Description Stock No. STN-2.5 2.5' Sampling Tube 1000274 STN-5 5' Sampling Tube 1000275 STN-10 10' Sampling Tube 1000276 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830099 - REV E • 8/19 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • 10 Amp Power Supply • 3 Amps, regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel • Isolated P-Link repeater connection, Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from AMSECO, Gentex, Cooper -Wheelock and System Sensor. Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link (RS-485) repeater. The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel. The power supply may be installed 6,500 feet from the control panel. The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six (6) Class B or three (3) Class A power outputs. Each output is regulated and power limited with a 3 Amp maximum rating. In addition, the PSN-1000 has two (2) programmable dry contact inputs. The dry contact inputs are Class B, supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output. In addition, the panel can charge up to 55 AH batteries and will house 18 AH batteries. The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish. A standard Potter key lock is provided for securing the door. Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet. The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet roomfor mounting stacker bracket modules including PAD 100-SLCE loop expanders. Both cabinets include space for 18 AH batteries. PSN-1000(E) Power Expander FM U` APPROVED 7165-0328: 0195 S2930 Technical Specifications PSN-1000: 16 3/4"x 161/8" x 3 1/2" Size (H x W x D) PSN-1000 E: 26" x 17.6" x 3.75" Enclosure Sixteen (16) gauge sheet steel with hinged, locked doors 120 VAC at 50 HZ Power Input 240 VAC at 60 HZ 5.1 Amps/3.0 Amps max draw Standby 60 mA Current Alarm 200 mA Temperature 32'to 120°F, humidity 93%non-condensing IPA Series, AFC/ARC Series, PFC-4064, Compatible Panles P Series*, PFC-6000 Adressable Series* * Legacy Product The power supplies are programmed and controlled through the main control panel P-Link bus. The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns, Amseco®, Gentex®, Cooper Wheelock® and System Sensor®. The ouputs can be also configured for constant power, resettable power, sounder base power, door holder power (with or without a low AC drop out), ANSI temporal Code 3, City Tie or be a releasing circuit for 24vdc solenoids. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830032 - REV E • 04/20 PAGE 1 OF 2 (E)POTTER The Symbol of Protection PSN-1000(E) Intelligent Power Supply 0 n 0 (� O • 00 0 0 oEl 0 0 o O L:E=] ��0000- E] �o 0 • 6 Class B / 3 Class A NAC Circuits • 2 Input Monitoring Points (IDC) • P-Link Circuit Repeater 0 0 4-Wire P-Link Circuit PSN-1000(E) Power Expander Potter Fire Alarm Control Panel 8 [2-j i ' o ioi o 0 Ordering Information Model Description Stock No. PSN-1000 Power Expander Standard Cabinet 3992662 PSN-1000(E) Power Expander Large Cabinet 3992665 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830032 - REV E • 04/20 PAGE 2 OF 2 CPOTTER RA-650OR The Symbol of Protection LCD ANNUNCIATOR INSTALLATION LISTED pending Description The RA-650OR is a LCD remote annunciator for the PFC-6000 series fire control panels. The RA-650OR communicates using a RS-485 connection to the main panel providing common indication of Alarms, Supervisory, Trouble and other system status and control functions. The RA-650OR features a 4x40 LCD display with LED's for Power, Alarm, Supervisory, Trouble, and Silenced conditions. It can be mounted on a single gang electrical box or a four square electrical box. The annunciator is enclosed in a sheet metal enclosure and has a Potter lock securing the keypad. Figure 1: RA-650OR Class B Wiring Example To the reKt annunciator ❑ WG. #e077.1 Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C (32°F-120°F) 10%-93% @ 30°C (86°F) non -condensing humidity Maximum Wire Length 6500 FT Maximum Annunciators 31 Size (WxHxD) 10" x 7-7/8" x 1-5/8" Wire Gauge 14 AWG-22 AWG Installation The RA-650OR is connected to the PFC-6000 series fire control panels using a four wire RS-485 connection. The connection is power limited and supervised. Up to thirty-one (31) RA-650OR LCD annunciators can be connected using Class B or Class A wiring. Class A wiring requires an optional Class A Expander. Install in accordance with installation manual, #540xxxx. !I Figure 2: RA-650OR Class A Wiring Example DWO. MN-1 Potter Electric Signal Company, LLC • St. Louis, MO • Cust Service: 866-956-1211 • Tech Support: 866-240-1870 • Canada: 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5406267 - REV A PAGE 1 OF 2 9/11 (E)POTTER The Symbol of Protection RA-650OR LCD ANNUNCIATOR INSTALLATION Address Settings The RA-650OR address is set by dip switch S 1 located on the back of the RA-6500R. The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3: RA-650OR Remote (panel view) 0 ❑ o 0 ��; O DIP SWITCH O 0 LEI A B O 0 DWG. #6077-2 Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Address Dip Switch Settings SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 2 Off On Off Off Off 3 On On Off Off Off 4 Off Off On Off Off 5 On Off On Off Off 6 Off On On Off Off 7 On On On Off Off 8 Off Off Off On Off 9 On Off Off On Off 10 Off On Off On Off 11 On On Off On Off 12 Off Off On On Off 13 On Off On On Off 14 Off On On On Off 15 On On On On Off 16 Off Off Off Off On Annunciator Address Dip Switch Settings SW-1 SW-2 SW-3 SW-4 SW-5 17 On Off Off Off On 18 Off On Off Off On 19 On On Off Off On 20 Off Off On I Off On 21 On Off On Off On 22 Off On On Off On 23 On On On Off On 24 Off Off Off On On 25 On Off Off On On 26 Off On Off On On 27 On On Off On On 28 Off Off On On On 29 On Off On On On 30 Off On On On On 31 On On On On On PRINTED IN USA MFG. #5406267 - REV A PAGE 2 OF 2 9/11