Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-1383_Manufacturer_Specifications_and_Installation_Instructions_10.11.2022_10.21.55_AM_3157533
FNNOX PRODUCT SPECIFICATIONS ELITE @ SERIES LENNOX QUANTUMTM COIL MODEL NUMBER IDENTIFICATION EL 16: Product Tier EL = Elite® Series Nominal SEER Refrigerant Type X = R-410A Unit Type P = Heat Pump Outdoor Unit Cooling Stages 1 = Single Stage Compressor HEAT PUMP OUTDOOR UNITS E L16X P1 ELITE° Series R-410A Bulletin No. 210880 March 2019 s SEER up to 17.00 HSPF up to 9.80 1.5to5Tons Cooling Capacity - 18,000 to 58,500 Btuh Heating Capacity - 16,900 to 56,000 Btuh Ilk P1-036-230A01 Revision Number Ratings Revision Letter Voltage 230 = 208/230V-1ph-60hz Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons FEATURES Wei rh,d=1'14h&I Dimensions ... Electrical Data Features......... Field Wiring .......................... Installation Clearances ........ Model Number Identification ................... Optional Accessories - Order Separately Sound Data ............................................ Specifications. TXV Usage.... WARRANTY 10 .7 .2 .9 .9 .7 .9 .7 11 Compressor - Limited warranty for ten years in residential installations and five years in non-residential installations. All other covered components - Five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPRnVAI C AHRI Certified to AHRI Standard 210/240. For AHRI Certified system match -ups and expanded ratings, visit www.LennoxPROs.com. Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in AHRI Standard 270. Tested in the Lennox Research Laboratory environmental test room. Rated According to U.S. Department of Energy (DOE) test procedures. Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are ETL certified for U.S. and Canada. ISO 9001 Registered Manufacturing Quality System. ENERGY STAR° certified units are designed to use less energy, help save money on utility bills, and help protect the environment. Many Lennox home comfort systems meet ENERGY STAR requirements when used with matching components. VIP APPLICATIONS 1.5 through 5 tons. Sound levels as low as 71 dB. Single phase power supply. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Designed for applications with remotely located indoor air handler units or gas furnaces with indoor add -on coils. When heat pumps are used with gas furnaces, a dual -fuel compatible thermostat or a zone control system with dual -fuel capabilities must be used (order separately). See Indoor Coils and Air Handlers sections for indoor unit data. Units shipped completely factory assembled, piped and wired. Each unit is test operated at the factory ensuring proper operation. Installer must set outdoor unit, connect refrigerant lines and make electrical connections to complete job. For expanded ratings, see www.LennoxPROs.com. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 2 FEATURES REFRIGERATION SYSTEM R-410A Refrigerant Non -chlorine, ozone friendly, R-410A. Unit is factory pre -charged with refrigerant. Total system refrigerant charge is dependant on outdoor unit size, indoor unit size and refrigerant line length. Refer to the unit -mounted charging sticker to determine correct amount of charge required. See Specification table. OOutdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire outdoor coil for high refrigerant cooling capacity. EL16XP1-036-042-048-060 models have a variable - speed outdoor fan motor for quiet operation. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has ball bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion Fan guard constructed of corrosion -resistant PVC (polyvinyl chloride) coated steel. Fan service access accomplished by removal of fan guard. OQuantuml- Coil Enhanced aluminum alloy tube/enhanced fin coil for superior corrosion resistance. Lennox designed and fabricated coil. Ripple -edged aluminum fins. Aluminum tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning. ©High Pressure Switch Protects the system from high pressure conditions that can be a result of fan failure or a blocked/dirty coil. Automatic reset. Low Pressure Switch Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset. OExpansion Valve - Outdoor Unit Designed and sized specifically for use in heat pump system. Sensing bulb is located on the suction line between the coil and the reversing valve thus sensing evaporator out temperature in the heat cycle. Factory installed and piped. ©Reversing Valve 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. Valve operates on pressure differential between outdoor unit and indoor unit of the system. Factory installed. OHi-Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular -sieve bead type drier. Optional Accessories Check/Expansion Valve Kits Must be ordered separately and field installed on certain indoor units. SeeTXV Usage table. Chatleff style fitting. Loss of Charge Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally -closed switch, automatic reset switch. Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it's setpoint. Opens at 29°F and closes at 58°F. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. Not available for -060 models and must be field fabricated. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 3 FEATURES COMPRESSOR OScroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. The muffler in discharge line reduces operating sound levels. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll r remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Compressor Crankcase Heater (Factory Installed on-036-042-048-060) Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication. Compressor Sound Dampening System A polyethylene compressor cover containing a 2 inch thick batt of fiberglass insulation for better sound dampening. All open edges are sealed with a one -inch wide hook and loop fastening tape. Optional Accessories OCompressor Crankcase Heater (Optional for-018-024-030 models) Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication. CONTROLS GDefrost Control Control furnished as standard. Gives a demand defrost cycle whenever system heating performance falls below optimum levels. The sensing element on coil determines when defrost cycle is required and when to terminate cycle. Anti -short cycle (5 minutes) incorporated into the board. Diagnostic LED's furnished as an aid in troubleshooting. Conveniently located in control box. Optional Accessories Compressor Low Ambient Cut -Off Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F. Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally does not need a potential relay and start capacitor. In conditions such as low voltage, kit may be required to increase the compressor starting torque. Indoor Blower Off Delay Relay Delays the indoor blower -off time during the cooling cycle. See AHRI System Matches for usage. Loss of Charge Switch Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally -closed switch, automatic reset switch mounted on suction line. Low Ambient Kit Heat pump in the cooling mode will operate satisfactorily down to 45°F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30°F in the cooling mode. Crankcase heater (optional for-018-024-030 models) and Freezestat should be installed on compressors equipped with a low ambient kit. A compressor lock -out thermostat should be added to terminate compressor operation below recommended operation conditions. Monitor Kit - Service Light Contains ambient compensating thermistor and service light thermostat. For use with thermostats requiring input for indicator lights. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 4 FEATURES CONTROLS (continued) Optional Accessories (continued) Mild Weather Kit Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75°F. Mild Weather Kit can be field installed, allowing heating operation above 75°F. Outdoor Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two stage control is applicable. Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line. Thermostat kit and mounting box must be ordered separately. iComfort® E30 Smart Wi-Fi Thermostat Wi-Fi enabled, electronic 7-day, universal, multi -stage, programmable, touchscreen thermostat. 3 Heat/2 Cool. Auto -changeover. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol° control, and equipment maintenance reminders. Easy to read 7 in. color touchscreen (measured diagonally). LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required). Smooth Setback Recovery starts system early to achieve setpoint at start of program period. Compressor short -cycle protection (5 minutes). Up to four separate schedules are available plus Schedule IQTM. One -Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away. Smart AwayTM - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving. Apple HomeKitTm enabled, making it easy to control the E30 thermostat from an iPhone, iPad or iPod device. Use Siri° voice commands to control the E30 thermostat. Amazon° Alexa-enabled, smart -home compatible. It works with Amazon Echo, Echo Dot and Tap devices. Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. High Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. Additional indoor air quality comfort products (PureAirTM Air Purification System, Healthy Climate° Humidifiers, Humiditrol° Enhanced Dehumidification Accessory, Healthy Climate° Energy/Heat Recovery Ventilators, Healthy Climate° Germicidal Lights) can be added to the system for a complete total -comfort system. See the iComfort° E30 Smart Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor Used with the iComfort° E30 Smart Thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto -detected when connected to thermostat. NOTE - Sensor is required for Enhanced Dehumidification Accessory (EDA) applications. Thermostat Thermostat (programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 5 FEATURES CABINET Heavy -gauge steel construction Pre -painted cabinet finish. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. Drainage holes are provided in base section for moisture removal. High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture. PermaGuardTM Unit Base Durable zinc -coated base section resists rust and corrosion. ®SmartHingeTm Louvered Coil Protection Steel louvered panels provides complete coil protection. Panels are hinged to allow easy cleaning and servicing of coils. Panels may be completely removed. Interlocking tabs and slots assure tight fit on cabinet. ®Refrigerant Line Connections, Electrical Inlets and Service Valves Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing. Optional Accessories Snow Guard For use in locations where the possibility of heavy snow or freezing rain accumulation may occur. Heavy gauge powder coated steel guard deflects snow and ice away from the outdoor fan and prevents build- up on the fan guard. NOTE - Snow Guards for 018-024-030 models are only available in Canada. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 6 SPECIFICATIONS General Model No. Data Nominal Tonnage EL16XP1-018 EL16XP1-024 EL16XP1-030 EL16XP1-036 1.5 2 2.5 3 Sound Rating Number (dBA) 71 72 72 72 Connections Liquid line (o.d.) - in. (sweat) Suction line (o.d.) - in. 3/8 3/8 3/8 3/8 3/4 3/4 3/4 7/8 Refrigerant 2 R-410A charge furnished 7 lbs. 2 oz. 7 lbs. 14 oz. 8 lbs. 4 oz. 8 lbs. 7 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 24.5 18.7 18.7 22.2 - - - 18.0 18.0 21.5 5/16 5/16 5/16 5/16 1 2 2 2 22 22 22 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 22 22 22 26 3 3 3 3 1/6 1/6 1/6 1/3 2670 2575 2575 3700 867 866 866 820 160 163 163 200 Shipping Data - lbs. 1 pkg. 213 211 211 214 ELECTRICAL DATA Line voltage data - 60hz 208/23OV--1 ph 208/23OV-1 ph 208/23OV-1 ph 208/23OV-1 ph S Maximum overcurrent protection (amps) 20 20 25 35 4 Minimum circuit ampacity 12.2 13.6 16.4 20.9 Compressor Rated load amps Locked rotor amps Power factor 9 10.1 12.3 14.7 48 52 63 75 0.98 0.98 0.96 0.99 Outdoor Fan Motor Full load amps Locked rotor amps 1.0 1.0 1.0 2.6 1.9 1.9 1.9 --- CONTROLS iComfort® E30 Smart Wi-Fi Thermostat 15S63I Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 931VI04 Factory Compressor Hard Start Kit LG 88M91 Compressor Low Ambient Cut -Off 45F08 Freezestat 3/8 in. tubing 5/8 in. tubing 93G35 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 5 Low Ambient Kit 54M89 Mild Weather Kit 11697 Monitor Kit - Service Light 76F53 Outdoor Thermostat Kit Thermostat Mounting Box 1 OZ23 31461 Refrigerant Line Sets L15-41-20 L15-41-30 L15-41-40 L15-41-50 6 Snow Guard 35-1/2 x 31 in. (Canada Only) X8780 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270. 2 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. s HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. s Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 6Add 11-1/2 inches (292 mm) to unit height. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 7 SPECIFICATIONS General Model No. Data Nominal Tonnage EL16XP1-042 EL16XP1-048 EL16XP1-060 3.5 4 5 Sound Rating Number (dBA) 73 73 73 Connections Liquid line (o.d.) - in. (sweat) Suction line (o.d.) - in. 3/8 3/8 3/8 7/8 7/8 1-1/8 Refrigerant 2 R-410A charge furnished 11 lbs. 4 oz. 11 lbs. 10 oz. 11 lbs. 6 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 29.1 29.1 29.1 28.2 28.2 28.2 5/16 5/16 5/16 2 2 2 22 22 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 26 26 26 3 3 4 1/3 1/3 1/3 4150 4150 4250 820 820 820 216 216 245 Shipping Data - lbs. 1 pkg. 294 294 300 ELECTRICAL DATA Line voltage data - 60hz 208/23OV-1ph 208/23OV-1ph 208/230V-1ph 3 Maximum overcurrent protection (amps) 40 40 50 ° Minimum circuit ampacity 25 25.8 30.4 Compressor Rated load amps Locked rotor amps Power factor 15.9 18.5 22.2 112.3 124 127.9 0.99 0.99 0.99 Outdoor Fan Motor Full load amps 2.6 2.6 2.6 CONTROLS iComfort® E30 Smart Wi-Fi Thermostat 15S63 Remote Outdoor Temperature Sensor X2658I OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Hard Start Kit Copeland LG 1OJ42 88M91 Compressor Low Ambient Cut -Off 45F08 Freezestat 3/8 in. tubing 5/8 in. tubing 93G35 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 5 Low Ambient Kit 54M89 Mild Weather Kit 11B97 Monitor Kit - Service Light 76F53 Outdoor Thermostat Kit Thermostat Mounting Box 1 OZ23 31461 Refrigerant Line Sets L15-65-30 L15-65-40 L15-65-50 6 Snow Guard 39-1/2 x 35-5/8 in. Y1033 NOTE -Extremes of operating range are plus 10% and minus 5% of line voltage. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270. 2 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. HACR type breaker or fuse. " Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Crankcase Heater and Freezestat are recommended with Low Ambient Kit. e Add 11-1/2 inches (292 mm) to unit height. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 8 SOUND DATA 1 Unit Model Octave Band Sound Power Levels dBA, re 10-11 Watts Center Frequency - HZ 1 Sound Rating Number (dBA) 2 Estimated Sound Pressure Level at Distance From Unit (dB at distance in ft.) 125 250 500 1000 2000 4000 8000 3 5 10 15 50 018 56.5 62 65.5 66.5 62.5 59.5 52 71 64 59 53 50 39 024 54.5 62 67.5 67.5 63 58 50.5 72 65 60 54 51 40 030 54.5 62 67.5 67.5 63 58 50.5 72 65 60 54 51 40 036 56 61 66.5 65.0 62 57 49 72 65 60 54 51 40 042 57 62.5 68.5 67.5 65 59 50.5 73 66 61 55 52 41 048 57 62.5 68.5 67.5 65 59 50.5 73 66 61 55 52 41 060 54.5 60.5 66.5 68 65 61 56 73 66 61 55 52 41 NOTE - the octave sound power data does not include tonal correction. Tested according to AHRI Standard 270-2008 test conditions. 2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. FIELD WIRING FDISCONNECTI SWITCH I (By Others) I r , B A - Two Wire Power (see Electrical Data) OI B - Two or Three Wire Power (size to heater capacity) ELECTRIC HEAT r_ _ _ _ DISCONNECTi C -Twelve Wire Low Voltage 18 ga. minimum r OPTIONAL I---- —j I SWITCH I (By Others) Fourteen Wire Low Voltage with Optional Outdoor OUTDOOR I I i_ Thermostat �THERMOSTAT� LENNOX INDOOR UNIT f — — — — — I THERMOSTATI D - Eight Wire Low Voltage 18 ga. minimum Ten Wire LVoltage with Optional Outdoor Thermostat ow g LENNOXOptional) OUTDOOR NOTE - Field Wiring Not Furnished UNIT All wiring must conform to NEC or CEC and local electrical "J C codes. INSTALLATION CLEARANCES NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm ) and the final side may be 6 in. (152 mm). A clearance of 24 in. (610 mm) must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. See NOTES T Control See NOTES Box EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 9 DIMENSIONS r TOP VIEW C (Depth) DISCHARGE AIRt� SIDE VIEW UNIT SUPPORT FEET \ VAPOR LINE CONNECTION LIQUID LINE CONNECTION LIQUID LINE CONNECTION ELECTRICAL INLETS VAPOR LINE CONNECTION 4-3/4 4-1/4 (108) (121) 172) 0 20-5/8 (524) on 7-3/4 (197) 4-1/2 (114) 3 1/4 27-1/8 3 5/8 (83) (689) (92) EL16XP1-018 TO -030 BASE SECTION (Medium Base) 1 (25) END VIEW UNIT SUPPORT FEET 16-7/8 (429) 26-7/8 (683) 8-3/4 (222) 3-3/4 (95) 3-1/8 30-3/4 (781) 4-5/8 (79) (117) EL16XP1-036 TO -060 BASE SECTION (Large Base) Model No. A in. mm B in. mm C in. mm EL16XP1-018 45 1143 30-1/2 775 35 889 EL16XP1-024 35 889 30-1/2 775 35 889 EL16XP1-030 35 889 30-1/2 775 35 889 EL16XP1-036 35 889 35-1/2 902 39-1/2 1003 EL16XP1-042 45 1143 35-1/2 902 39-1/2 1003 EL16XP1-048 45 1143 35-1/2 902 39-1/2 1003 EL16XP1-060 45 1143 35-1/2 902 39-1/2 1003 EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 10 TXV USAGE Use this table for C35, CH23, CH33, CH35 and CR33 Field Installed TXV Match -Ups. Model No. Order No. 12J18 12.1118 12J18 12J 19 EL16XP1-018 EL16XP1-024 EL16XP1-030 EL 16XP 1-036 EL16XP1-042 12.120 EL16XP1-048 12J20 EL16XP1-060 12.120 CX35 and CHX35 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. C35 and CH33/CH35 coils - Replace the factory installed orifice with the expansion valve listed. CR33 and CH23 - Use the expansion valve listed. MOST POPULAR MATCHES Outdoor Model No. Outdoor Model No EL16XP1-018 CBA27UHE-018 EL 16XP 1-024 CBA27UHE-024 EL 16XP 1-030 CBA27UHE-030 EL 16XP 1-036 CBA27UHE-036 EL 16XP 1-042 CBA27UHE-048 EL 16XP 1-048 CBA27UHE-048 EL 16XP 1-060 CBA27UHE-060 AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air -circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. EL16XP1 - 1.5 to 5 Ton Heat Pump / Page 11 LENNOX --7 0 © MEMBER COMPANY Visit us at www.lennox.com O(TSTF-0 CUS ntertek For the latest technical information, www.LennoxPROs.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2019 Lennox Industries, Inc.