Loading...
ENG2022-0322 ROW PERMITOF WAY EUC PERMIT o PERMIT NU M City of Edmonds EdmondsRIGHT 98020 1 1 www.cityofedmonds.gov / i RL Description: COMCAST-MOVE DOGHOUSE 2 FT FOR SPENCE SP (PLN2017-0057) ISSUED: 10/11/2022 Address: 17606 72ND AVE W EDMONDS WA 98026-5500 EXPIRES: 04/11/2023 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00513600000100 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT TERESA STEMLER 410 VALLEY AVE NW, PUYALLUP WA 98371 (425)770-0020 CONTACT CABLECOM 19910 NORTHCREEK PARKWAY NORTH, BOTHELL WA 98011 (360)622-5388 CONTRACTOR CABLECOM LLC 20021 120TH AVE NE, SUITE 101, BOTHELL WA 98011 (360)863-2628 OWNER DUNCAN & STEPHANIE SPENCE 17606 72ND AVE W, EDMONDS WA 98026 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00 ENGINEERING INSPECTION FEE $110.00 $110.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $330.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 10/11 /2022 RELEASED BY DATE Printed: Tuesday, October 11, 2022 1:38:48 PM 1 of 2 oe e n,y RIGHT OF WAY EUC PERMIT sAd - City of Edmonds Edmonds98020 1 1 www.cityofedmonds.gov / i CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" Printed: Tuesday, October 11, 2022 1:38:48 PM 2 of 2 RESUB y of ED% ��`' RIGHT OF WAY CONSTRUCTION AugO CITY OF EDMONDS2 PERMIT APPLICATION DEVELOPMENT SERVICES DEPARTMENT Complete and submit this Application in accordance with the Submittal l'vc. Ise0 Requirements outlined in Right -of -Way permit Handout E63. If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. SECTION A General• Project Name COMCAST - JB0001056365 Site Address or if no site address use Property Address at NW corner of project area: 17606 72ND AVE W, EDMONDS WA 98026 Associated Permits: BLD PLN ENG Owner and Entity Holding Franchise (if applicable) Name of CompanyCOMCAST CABLE HOLDING Franchise Ordinance No: Point of Contact J ESSAM I N SANTOS Title PERMIT COORDINATOR Address 410 VALLEY AVE NW City EVERETT State WA Zip 98371 Phone 206-401-2188 EmailWACONSTRUCTION JOINTUSE@COMCAST.COM Contractor and Authorized Agent of •wner (see note below) Name of Company CABLECOM LLC Contractor ContactsDuring Construction Primary Name CABLECOM LLC - MICHAEL FINCH Agent NameLEAH IHLENFELDT Title CONSTRUCTION SUPERVISOR Title PERMIT SUPERVISOR Mobile 360-965-5085 Address 19910 NORTHCREEK PARKWAY N Email MICHAEL.FINCH@CABLECOMLLC.NET City BOTHELL State WA Zip 98011 Secondary Name Phone 360-820-8984 Title Email SNOHOMISH.PERM ITTING@CABLECOMLLC. NET Mobile City of Edmonds Business License No: N R-021818 Email State License No: CABLEL*971 DP 91 Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o.02o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as well) ❑ Traffic Control Only (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 V� Utility Franchise Work (no associated development) Project Description Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) MOVE EXISTING DOG HOUSE 2' SOUTH AND OUT OF THE WAY. THE CITY IS DOING A RE -PAVING PROJECT. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF IxI LF SF Alley 72 hours + LF IxI F SF Parking 72 hours + LF IxI LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications d cable ❑ power ❑ gas ❑ water ❑ sewer ❑ storm 1. CompletedDetails of Work to be Does the utility owner have existin overhead infrastructure in the area of work? • 2. Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X /� 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existingunderground common utilitysystem? X 5. Does the work involve proposed additions to an aboveground utility system? If es: Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of • to be Completed ®i 6. Does your project involve rebuilding or replacing utility equipment which currently serves more X than one lot or commercial development? /� City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: How many are existing? I I How many are to be added? 6b. Does your project involve poles? If yes: How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: How many? What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: Ldl'-ZC 'T L DATE: 8/17/2022 APPLICANT PRINTED NAME: LENAIZA ENRIQUEZ APPLICANT TITLE: PERMIT COORDINATOR NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 CONTACTS KEVIN HARMON CONSTRUCTION MANAGER CABLECOM KEVIN. HARMON @CAB L E COM LLC. NET 360.322.2805 SPENCER KARINIEMI OPERATIONS MANAGER BOOKER ENGINEERING SPENCER@BOOKERENG.COM 360.722.2852 SHEETINDEX 1 - COVER SHEET 2-GENERAL NOTES 3-LEGEND 4 - DESIGN VIEW 5 - SITE PHOTOGRAPHS SCOPE OF WORK MOVE EXISTING COMCAST PEDESTAL 4' (SE) TO PROPOSED LOCATION NEAR 17606 72ND AVE W. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. RESUB SEP 23 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 'll .lNb' Ol ONUV i .. _............ ........._ ...._... _ 1 LOCATION OF UNDERGROUND FACILITIES. 2 CONFIDENTIAL/ PROPRIETARY AS -BUILT ADDRESS: 17600 72ND AVE W, EDMONDS, WA 98026 PROJECT NAME: J B0001056365 - PRINTS R • ... ♦ bVICINITY • All Picnic Lynnwood dale Park • a•� {� OlIlk- op ' • Lynnwood ER 5 All ze rA Sll J. SITE LOCATION I IONS CABLECOM ENGINEER: KEVIN HARMON 7ZOZ/SO/0 ING LLC i TER DATE �19VNIV2iQ N` IO0 JINOO OH1 ] `190, DR 09/16/22 PROJECT NUMBER: JB0001056365 �,,y,.p ,. ____ ____ ___- C O M C A S T Caws m PERMIT NUMBER: ---- NOISIAI DMtJ 3NIJN3 15. (8- Know what's below. SHEET NUMBER Call before you dig. 1 OF 5 GENERAL NOTES 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS: ---- CURRENT INTERNATIONAL BUILDING CODE (IBC) ---- 2016 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION ---- WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (CURRENT EDITION) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL ASBUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (i.e. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM DOWNSTREAM OF THE SITE STORMWATER DETENTION SYSTEM. 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO JEFF.KOBLYK@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. RES U B 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH V APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ONSITE EROSION AFTER THE SEP 23 2022 COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. CITY OF EDMONDS DEVELOPMENT 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. SERVICES DEPARTMENT THE ACT UAL LOCATION OF EXISTING CONDUIT AND REVISIONS CABLECOM ENGINEER: KEVIN HARMON BOOKER ENGINEERING LLC CABLES MAY VARY FROM THE LOCATION SHOWN. BOOKER ENGINEERING DISCLAIMS ANY NO. ENGINEER DRAFTER DATE 16778 146TH ST SE #190, • RESPONSIBILITIES FOR DAMAGES INCURRED TO ANY i FAOILITIES NSW IRKING NOT SHOWN INTHESE ORIGINAL SDK ADR 09/16/22 ` /� Eb PROJECT NUMBER: JB0001056365 MONROE, WA 98272 • m PRINTS. PERSONS WORKING IN THE AREA COVERED ,.. i BY THIS DRAWING MUST CONTACT THE STATEWIDE ____ ____ ____ 360.722.2852 CALL -BEFORE -YOU -DIG SYBTEM TO CONFIRM THE C O M C A S T LOCATION OF UNDERGROUND FACILITIES. 2 CableCOf11 PERMIT NUMBER: ---- Know ____ ____ � Know what's below. SHEET NUMBER CONFIDENTIAL/ PROPRIETARY AS -BUILT ---- ____ ---- PROJECT LOCATION: 17600 72ND AVE W, EDMONDS, WA 98026 Call before you dig. 2 OF 5 SYMBOLS CATCH BASIN/INLET ® RISER — EXISTING ® RISER — PROPOSED FIRE HYDRANT POLE ANCHOR/DOWN GUY —EXISTING WATER/GAS VALVE POLE ANCHOR/DOWN GUY — PROPOSED LIGHT POST POLE ANCHOR/DOWN GUY — EXISTING STREET SIGN 01 AERIAL STORAGE — EXISTING 0, AERIAL STORAGE — PROPOSED ADA RAMP SPLICE POINT — EXISTING SPLICE POINT — PROPOSED BUSH V UTILITY VAULT — EXISTING (SIZE MAY VARY) HEDGE UTILITY VAULT — PROPOSED (SIZE MAY VARY) UTILITY PEDESTAL — EXISTING O (SIZE MAY VARY) TREE UTILITY PEDESTAL — PROPOSED o D © (SIZE MAY VARY) OUNDERGROUND STORAGE — EXISTING OTREE STUMP OUNDERGROUND STORAGE — PROPOSED UTILITY POLE — ® UTILITY POTHOLE EXISTING BORE/TRENCH —PROPOSED UTILITY POLE — (SIZE MAY VARY) PROPOSED LEGEND SYMBOLS CONT. LINETYPES RESTORATION LIMITS A AERIAL FIBER —EXISTING (SIZE MAY VARY) A AERIAL FIBER — PROPOSED n — — — — — — — — CONDUIT — EXISTING I UTILITY CONTINUES — — — — — — — — CONDUIT — PROPOSED CENTER LINE/STATION LINE — UTILITY ENDS R/W RIGHT OF WAY PARCEL BOUNDARY SEW SANITARY SEWER OCONSTRUCTION NOTE/RESTORATION CALLOUT SD STORM DRAIN W WATER (X) PHOTO LOCATION/ORIENTATION CALLOUT G GAS ��// STM STEAM (XXX') DIMENSIONS FROM PREVIOUS PAGE E ELECTRIC F/0 FIBER OPTIC RETAINING WALL T TELEPHONE UNK UNKNOWN UTILITY X X FENCE NORTH ARROW ORT HATCH PATTERNS INFORMATION TABLES 0 oa a 0 0 o CONCRETE SIDEWALK a O O O O O GRAVEL O O O O O 0 0 0 0 0 0 BRICK/COBBLE WATER BODY #F IN: 0 OUT: 0 #F IN: 0 TAIL: 0 #F TAIL: 0 OUT: 0 TITLE N/A UTILITY1 0'-0" PROP UTILITY 1 0'-0" SEQUENTIAL IN/OUT CALLOUT SEQUENTIAL IN/TAIL CALLOUT SEQUENTIAL TAIL/OUT CALLOUT UTILITY POLE INFORMATION TABLE (NUMBER OF ATTACHMENTS MAY VARY) RESUB SEP 23 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT THEACTUAL LOCATION OF EXISTING CONDUIT AND REVISIONS CABLECOM ENGINEER: KEVIN HARMON BOOKER ENGINEERING LLC CABLES MAY VARY FROM THE LOCATION SHOWN. BOOKER ENGINEERING DISCLAIMS ANY NO. ENGINEER DRAFTER DATE 16778 146TH ST SE #190, RESPONSIBILITIES FOR DAMAGES INCURRED TO ANY FACILITIES SHOWN OR NOT SHOWN IN THESE ORIGINAL SDK ADR 09/16/22 PROJECT NUMBER: JB0001056365 MONROE, WA 98272 PRINTS. PERSONS WORKING IN THE AREA COVERED E By THIS DRAWING MUST CONTACT THE STATEWIDE ____ ____ ____ 360.722.2852 CALL-BEFORE-OFU ND SYSTEM TO CONFIRM THE 1 C O M C A S T cmieco L-BEFO q) OCATIONO U-DIG SYSTEMT FACILITIES. PERMIT NUMBER ---- 2 ____ ____ ____ Know what's below. SHEET NUMBER CONFIDENTIAL/ PROPRIETARY AS -BUILT ____ ____ ____ PROJECT LOCATION: 17600 72ND AVE W, EDMONDS, WA 98026 Call before you dig. 3 OF 5 9 d0 b sl=„l 31V�s ---- ---- ---- llln8-SV Blp noR ajojaq lleo 9Z086 VM `SaNOWa3 `M 3/�V dNZL 009L1 NOIlW001 lO3f O`dd l aWl3ladOad /1WI1N341dN00 a38WnN 133HS molaq s,aeyMMouN`7alQe`7 Z 1 S v z)W O o ---- ---- ---- - a38Wf1N 11Wa3d '531111I0tld ON00210TJ30Na d0 NOI1tlOOl 3H1 MIUNOO OI W31SAS o10Y10A-380d38-11VO H1dON Z98Z ZZL 09E 30IM31V1S3H110V1NOO1SNWoNIM"OSIHIAS 03H3AO3 V3HV 3H1 NI ONINbOM SNOSH3d'S1NIbd ZLZ86 VM `30a NOW 99£9901,00081:H38WnN 103rOHd ��1` ZZ/91,/60 ZRIV NGS �b NIJRiO 3S3H1 NI NMOHS ION HO NMOHS S311110VA ANV Ol a3?JHnONI S3OtlWV0 HOA S3111lISISNOdS3H 061,# 3S 1S H19b6 8LL96 C331V(1 a31=WHO a331\1I01\13 'ON ANV SWIV13SI0 oNI?93NION3i13X009 011 I NMOHSNWO )NIa33NIJN3a3NO08 NOWaVH NIA3>i2i33NIJN3 N00310VO aNV1faNO39NIISIX3 d0 NOIIV0O1 ivnIOV 3H 1 'SHdVi10010Hd 311SNOd S# 133HS 33S' NOUV1N3121O EROSION CONTROLAND DRAINA ONV SN011V00101OHd Ol SONOdS3HHOO 108WAS Applicant shall repair/replace all damage to utilities or frontage 1N3W1aVdDO S30WtIDS OWNER/CONTRACTOR RESPONSIBL E FQRvIeQGATkW#' right-of-way 1N3WdO1DA34 SaNOWa3 d0.1110 ALL ON SITE UTILITIES. RELOCATION REVMOW�VAWis caused or UTILITIES MAY REQUIRE A SEPE Ttup�Ro t,e permitted project. zMz £Z d3S sns3U ENGINEERING DIVISION @(I 0/05/2022 x 001.000009£ 1900 #130aVd M 3AV dNZL 909L1, lid 014 l tiX,ti MIN M/N MIN X M/N MIN MIN /N M/N M/? ,b•E d ,9 d 0 lid 010 ,tiX,ti -M M V M M A V i` M M M M NOlionalsNoo ONiana M3S MSS— -MIS MIS X08�IVW 30V1d3a aNV 3AOW3a �S MIS MSS MIS MSS 'S33J NOudnisia MS 1S H19L WONI TIVHS 0 M3N NI sino ANV 'NOI114N0D ? Md 013DVd? s LOS MOB32 O S310N NOIlV2]OlS32i 0 'N011VD01 03SOdO2 d Ol (3S) ,b 1V1S3a3d 1SV0W019NUSIX3 3AOW O S310N NOIiomJ1SNO0 M M/ p D 0 DD U M/ 2t-7 ZO£L0000099b00 #130aVd I MS 1S H19L1 11•ZL In 0 M M M Mk M n M/a M/N MIN 1,0£10000099b00 #130aVd I 0017100000991700 #130aVd MS 1S H19L 1 91,ZL MS 1S H19L 1, 6ZZL PHOTO #1: FACING (S) ON THE (S) SIDE OF 176TH ST SW SITE PHOTOGRAPHS - 4'X4' DIG PIT CONSTRUCTION NOTES O MOVE EXISTING COMCAST PEDESTAL 4' (SE) TO PROPOSED LOCATION. RESTORATION NOTES O RESTORE SOFT SURFACE TO PRIOR CONDITION. RESUB SEP 23 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT THEAC CABLES ALLOCAYTION OF EXISTING FROMTHELOCATION CONDUIT AND REVISIONS CABLECOM ENGINEER: KEVIN HARMON BOOKER ENGINEERING LLC MAYBOOKER ENGINEERING DISCLAIMS ANY NO. ENGINEER DRAFTER DATE 16778 146TH ST SE #190, RESPONSIBILITIES FOR DAMAGES INCURRED TO ANY FACILITIES SHOWN OR NOT SHOWN IN THESE ORIGINAL SDK ADR 09/16/22 Eb PROJECT NUMBER: JB0001056365 MONROE, WA 98272 PRINTS. PERSONS WORKING IN THE AREA COVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE ____ ____ ____ 360.722.2852 CALL -BEFORE -YOU -DIG SYSTEM TO CONFIRM THE C O M C A S T L15. OCATION OF UNDERGROUND FACILITIES. 2 CableC0lil PERMIT NUMBER: ---- Know ____ ____ � Know what's below. SHEET NUMBER CONFIDENTIAL/ PROPRIETARY AS -BUILT ---- ___- ---- PROJECT LOCATION: 17600 72ND AVE W, EDMONDS, WA 98026 Call before you dig. 5 OF 5 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 123' 172' 74' 100' 150' PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED J z C � m � I I I X I X X I X ONE LANE ROAD AHEAD 48" W20-4 48" W20-7A ROAD BE WORK <PREPARED HEAD 48" oa pal;lulaed ayl bulanp sin000 W20-1 2�}1q neo sl }ey; spiepue;s Alp aad `7�enA-;o-}y6u A;IO ul sluaW9Aoadwi W20-7(OPT Idn ao sal pin of ebewep ao M H oRe aoe daa/aledaa peys;ueollddV 319VNI`d 10 QMd-1021iN 210d 3_181SNOdS3] i SI 2]Oi:D ' JiNOO/2i3NM0 LEGEND 1� FLAGGING STATION a 'lll/ dR V�I �I &c`�(T tUni�32i �lb'W S3unin MV V Ol NOISIAIWNOIlVOMDIH 'S31111I1n 311S NO _I­Ib' JNiivd5&�IbT 99f 1kbsdS32J _H=Vb1NOOR13NMO I:= PROTECTIVE VEHICLE THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL DESIGN: REV DESCRIPTION DATE 0 ISSUE FOR PERMIT 06/21/2022 DRAWN BY: DOM APPROVED: APPROVED: APPROVED: 5070 300' SIGN SPACING = X (1) RURAL HIGHWAYS 60 / 65 MPH 800' +/- RURAL ROADS 45 / 55 MPH 500' +/- RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' +/- RURAL ROADS, URBAN ARTERIALS, RESIDENTIAL & BUSINESS DISTRICTS 25 / 30 MPH 200' +/- (2) URBAN STREETS 25 MPH OR LESS 100' +/- (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2 THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT OADWAY CONDITIONS. 50' TO 100' 50' TO 100' 6 DEVICE 6 DEVICE MI R B MIN. I WORK AREA 4N;= W20-713 (OPTIONAL IF 40 MPH OR LESS) // \\ n n " //W f 48" W20-7A X i X 176TH ST SW ONE —LANE, TWO—WAY TRAFFIC CONTROL (WSDOT TC1) WITH FLAGGERS NOT TO SCALE IMPORTANT NOTICE Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 BE \ PREPARED TO STOP/ W20-7B X 48" ROAD WORK HEAD 48" 48" ONE LANE W20-1 ROAD AHEAD 48" W20-4 X IN N 7ZOZ/90/0 iANNELIZATION DEVICE " SPACING (FEET) MPH TAPER TANGENT NOISIA Q ONI2J33N1 50/65 10TO20 80 35/45 10 TO 20 60 25/30 10 TO 20 40 NOTES 1 - ALL SIGNS ARE BLACK ON ORANGE. 2. EXTENDING THE CHANN€` gZINI&MVICE TAPER ACROSS SHOULDER IS REC6k*#i 11011AIa �0 Ailo 3. NIGHT WORK REQUIF?,Z@&ErjCJ0ACROADWAY LIGHTING AT FLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONS FOR ADDITIONAGSA 13 0 3 H 4. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS. 17606 72ND AVE W, EDMONDS, WA TRAFFIC CONTROL PROJ#: JB1056365-FORCED RELOCATE CONSTRUCTION TYPE: RELOCATE EXISTING CATV PEDESTAL SYSTEM: EDMONDS NODE: TC- 1 SHEET: 1 OF 1