APPROVED PLN BLD ENG RESUB1 BLD2021-1023+Building_or_Construction_Plan+10.15.2021_10.44.22_AM+2465498TARC U ENO SLOPE STABILIZATION 841 ELM WAY EDMONDS, WA 98020 OWNER JOETARQUENO 841 ELM WAY EDMONDS, WA 98020 708.439.4997 CONSULTANTS STRUCTURAL ENGINEER CG ENGINEERING 250 4TH AVE S, SUITE 200 EDMONDS, WA 98020 425.778.8500 FAX 778.5536 CONTACT: DENNIS TITUS, PE, SE GEOTECHNICAL ENGINEER NELSON GEOTECHNICAL 17311 135TH AVE NE. SUITE A-500 WOODINVILLE, WA 98072 435.486.1669 CONTACT: KHAL SHAWISH, PE LEGAL DESCRIPTION SEC 25 TWP 27 RGE 03RT-61A) BAAP ON N LN OF NE1/4 SW1/4 30 FT WLY FR NE COR NE1/4 SW1/4 TH CONT ALGSD N LN N88*18 30W 179.2FT TH S33*18 30E 119.69 FT TAP ON NLY MGN OF ELM WAY TH N56*41 30E ALG SD N MG OFELM WAY 135 FT TH N01*05 OOE 20.62 FT TOPOB. PARCEL NUMBER 27032500300100 PROPERTY INFORMATION PROPOSED BUILDING FOOTPRINT = NOT TO CHANGE TOTAL IMPERVIOUS SURFACE = NOT TO CHANGE SCOPE OF WORK REPLACE EXIST FAILING TIMBER RETAINING WALL WITH CONCRETE RETAINING WALL. TEMPORARY EROSION CONTROL NOTES 1. TEMPORARY EROSION CONTROL SHALL BE INSTALLED PER THE GEOTECHNICAL REPORT. REFER TO NELSON GEOTECHNICAL REPORT DATED 10/01/20. 2. EROSION CONTROL MATTING SHALL BE INSTALLED ON THE GROUND SURFACE PRIOR TO PLANTING. SPECIAL INSPECTIONS REQUIRED Geo Tech Engineer: 1) Shoring 2) excavation and fill Engineer: 3) Concrete Test 4) Concrete Placement ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work RETAINING WALL ----------------------------- ------------------------------ Address 841 ELM WAY Owner TARQUENO Approved Date 10/20/2021 Building Official:.__ l/�/ � �aIL Permit Number; BLD2021-1023 A J s D D 220th St SW 220th St SW 220th St SV,' 2201h St SVv 0 T D 0 0 s D 0 0 s VICINITY MAP NTS = PROJECT SITE / I / I / I � I I VOL. 18, PG. 42, 15' UTILITY EASEMENT PER PLAT OF SEA VISTA / I ' I / / --�----------------- FOUND REBAR & CAP OUTLET FOOTING DRAIN ON 3' N 88° 16'20" W 179. ' — - - — - - IS 10219" 0.2'(S) CX, D,, WIDE x 5' LONG QUARRY SPALL 77 ----------- 1 U LINED ROCK SPLASH PAD 0.2'(W) OF CORNER FOUND REBAR &CAP w o SILT FENCE / LJ 10219 0.1 (W) w O Lv OF CORNER o Q7) CN O O I Al SEE DETAIL --�, 4"0 PERFORATED / / Ile FOOTING DRAIN / PER DETAIL / PN 270.32500300100 ^ / 91925 SQ. FT. �o HOUSE #841 TPN 27032500300200100, PROPOSED LANDSCAPING WALLS, TYP REPLACE FAILING TIMBER / /�� / RETAINING WALL WITH CONCRETE RETAINING / � / Q / WALL ; I / fi V NEIGHBORING CMU FENCE, PROTECT DURIGN r� �\� /�01 I I� A�1 CONSTRUCTION 1. LV�V��V Ole 0 REMOVE EXIST 2 BLOCKWA`kLv' 0� / APPROVED BY PLANNING f o Oct 28 2021 SITE PLAN SCALE: 1" = 10' CONC. / CONTINUE RETAINING WALL TO EXISTING BLOCK WALL / o CO a / � / I E. FACE NEW WALL O PASSES R.O.W. LINE / 0.8'(W) OF CORNER FOUND REBAR �0 ' / 0.1'(W) OF �O�`��/ CORNER / / / / CB RIM=313.32 IE 6" PVC(N)=309.92 ��----�� IE 18" PVC(E)=309.82 / IE 8" PVC(S)=309.82 / 6 10 0 5 10 20 C3� ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 09117121 Z m � w q- v) M= LLJ LU LU 0 a- a w Q O O Y Q DESIGN: ZSH DRAWN: JEG CHECK: DMT JOB NO: 211 1 7.1 0 DATE: 06/ 1 1 /21 RES U B Oct 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z 0 Q N m F-- O N O LL1 00 CL O 0 (� Q Q Z � Q Z N 0— LLI J Z pw r 0 W ~ < o I- 00 w Cn ENGINEERING DIVISION SHEET: APPROVED. '11�aAt 10/15/2021 OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE somi OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. STRUCTURAL NOTES C3� (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. SPECIAL INSPECTION OPERATION CONT PERIODIC REMARKS SOILS SHORING X GEOTECH ENGINEER EXCAVATION & FILL X GEOTECH ENGINEER CONCRETE CONCRETE TEST SPECIMENS X CONCRETE PLACEMENT X NOTE: ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. FOUNDATIONS: SPREAD FOOTINGS SOILS REPORT: REPORT NO: PREPARED BY: NELSON GEOTECHNICAL DATED: ALLOWABLE SOIL PRESSURE: 3000 PSF LATERAL EARTH PRESSURE: UNRESTRAINED: PASSIVE: COEFFICIENT OF FRICTION 40 PCF + ANY APPLICABLE SURCHARGE 200 PCF 0.36 FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BY THE OWNER IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c* WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHRINKAGE STRAIN RATIO YARD SLABS ON GRADE 3000 PSI 0.55 5 1/2 SACK N/A FOOTINGS 3000 PSI 0.55 5 1/2 SACK N/A WALLS 3000 PSI 0.55 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE SUBMITTED. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP WELDED WIRE FABRIC 12" AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI 318, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE PER SCHEDULE. MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. REFER TO CHAPTER 25 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. MINIMUM LAPS AND EMBEDMENT UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED BELOW: f c = 3000 PSI DEVELOPMENT LENGTH LAP SPLICE BAR TENSION COMPRESSION TENSION COMPRESSION SIZE TOP BARS OTHER BARS ALL BARS TOP BARS OTHER BARS ALL BARS #3 22 17 9 28 22 12 #4 29 22 11 37 29 15 #5 36 28 14 47 36 19 #6 43 33 17 56 43 23 #7 63 48 20 81 63 27 #8 72 55 22 93 72 30 NOTE: 1. ALL LENGTHS ARE IN INCHES. 2. ALL LAP SPLICES ARE CLASS B. 3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH AND WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS AND JOISTS 3/4" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. GENERAL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING NATIVE SOIL GRANULAR FILL ��MI=l1=A�1=A15 — — — — — EXTENT OF FRAMING COLUMNS COLUMN BEARING ON BEAM BEAM CONTINUOUS OVER SUPPORT CONCRETE WALL STRUCTURAL STEEL RATED SHEATHING SHEAR WALL (SEE SCHEDULE) P SWX ell � COLUMN MARK (SEE SCHEDULE) BEARING STUD WALL FOOTING MARK (SEE SCHEDULE) O NON -BEARING STUD WALL HOLDOWN MARK (SEE SCHEDULE) BEARING STUD SHEAR WALL NON -BEARING STUD SHEAR WALL HANGER MARK (SEE SCHEDULE) FLAG NOTE (SEE PLAN NOTES) O CMU WALL STEEL MOMENT FRAME CONN. �V SILT FENCE X X ABBREVIATIONS (A) ABOVE GLB GLUE -LAMINATED BEAM AB ANCHOR BOLT ALTERNATE HORIZ KID HORIZONTAL KING POST ALT ARCH ARCHITECT KSI KIPS PER SQUARE INCH ANGLE (B) BELOW L BD BAR DIAMETER MECH MECHANICAL BLKG BLOCKING MF MOMENT FRAME BM BEAM MTL METAL BOT BOTTOM INS NEAR SIDE BRNG BEARING OC ON CENTER BTWN BETWEEN OPP OPPOSITE CJP COMPLETE JOINT PENETRATION PL PLATE CLR CLEAR PLCS PLACES CMU CONCRETE MASONRY UNIT PSI POUNDS PER SQUARE INCH COL COLUMN PSF POUNDS PER SQUARE FOOT POST TENSIONED PRESSURE TREATED CONIC CONCRETE P/T CONN CONNECTION PT CONT CONTINUOUS REINF REINFORCING REQUIRED COORD COORDINATE REQ'D DBL DIET DOUBLE DETAIL SCHED SCHEDULE SIMILAR SIM DIA DIAMETER SOG SLAB ON GRADE DIM DIMENSION STD STANDARD DIR DIRECTION EACH STIFF STIFFENER EA STL STEEL ELEV ELEVATION SYMM SYMMETRICAL SHEARWALL ES EACH SIDE SW EX EXISTING TOC TOP OF CONCRETE TOP OF STEEL EXP EXPANSION TOS FLR FLOOR TOW TOP OF WALL FDN FOUNDATION TYP TYPICAL FTG FOOTING FAR SIDE LINO UNLESS NOTED OTHERWISE FS VERT VERTICAL GC GENERAL CONTRACTOR WF WIDE FLANGE ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 09/17/21 i J � Q H_ H Z m O CoV) D w a- V) Of y H F- O 2 2 LJ w w � � a LLJ Q m O O Y Q' Q DESIGN: ZSH DRAWN: JEG CHECK: DMT JOB NO: 21117.10 DATE: 06/ 1 1 /21 RESUB Oct 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z 0 Q N m Q W O J O Z N W J D W Cy O Q 0 �-- 00 W SHEET: (n W 0 Z TEMPORARY EXCAVATION PLAN SCALE: 1" = 10' 10 0 5 10 4= 0- 4m�lh6 ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 310.................I......................................... 310 EXIST TIMBER WALL �� i M 305 7b BE REPLACED . I. .i/. . 305oF WASH j?� EXIST CMU FENCE 300 ----�� . 300 �'ss'�RaL �lrti ONAL 09117121 295 ....................................................... 295 SECTION L SCALE: 1" = 10' 5 R 320 ........... EXISTING GARAGE I 315 . . . . . . . . . . EXIST GRADE 310 .................I........ . EXIST TIMBER WALL TO BE REPLACED EXIST CMU FENCE 0 2.5 5 320 . . . . . . . . . . .+ 315 . . . . . . . . . . .+ 310 �305 305 - - - - - - - - . Q � EXIST BLDG PILES i i i 3 SECTION SCALE: 1" = 10' 5 T- 320 ........... EXISTING GARAGE I 315 . . . . . . EXIST TIMBER WALL EXIST GRADE TO BE REPLACED EXIST CMU I 310 . . . . . . .FENCE . 0 2.5 5 320 . . . . . . . . . . .+ 315 . . . . . . . . . . .+ 310 ti� �OQ 305 . . . . . . . . . . . . . 305 EXIST BLDG PILES 300 . .. . . . . . . . . . . . . . . ......... 300 U I 295 ......... ..... 295 SECTION 4 SCALE: 1" = 10' 10 10 J F- ~ F Z 2 m 0 Co can 0_ ::) V) w cf� H F— O (f) = Ld w w Q a a 'r-i r-i N N Q O O Y Q DESIGN: ZSH DRAWN: JEG CHECK: DMT JOB NO: 21117.10 DATE: 06/ 1 1 /21 RES U B Oct 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z O Q N J m H 0 O W 00 CL CY) 0 >- Q cna� 5 O Zui W J ::) W CY O Q �--� 00 W SHEET: VA P P- 1 mfPei 5 0 2.5 5 10 1 S2ml I I I I I I I TOW = 310.33 BOW = 308.0 TOW - 310.33 (� FOUNDATION BOW = 309.16 CONC v O I PER SCHEDULE - 31 .33 \ STEPS TOW = 310.33 I ( L 44% 6 1 1 309.16 �� 310.33 --- S3.1 1 L-- � _ ------------ ---� _= -- -- - - - ---3 EXIST BLOCK WALL _ 4' 1 C_ TO REMAIN -- _---- � \ E--------- f TOW - 308.0 J 308.0-------Z-------� - - - -1 TOW = 30 5 I I L I 99 TOW = 310.5 I PA CR WA L LSD e Sl) SD SD- SD- \ SID SD D SD SDSD \)SD SD -SD110 S�D�ZS� BOW = 310.0 4 n TOW = 310.5 5 TYP \ \ - O NEW CO Co BL Ck W BOW =304.0 <S:.1 O OZ TOW = 304.0 LANDSCAPING LANDSCAPING BOW = 300.0 TOW = 3016.0 TOW = 308.5\ STEP STEP BOW = 301.0 BOW = 302.0 TOW = 309.5 BOW = 303.0 i L----------------- ------------- ----------- RETAINING WALL PLAN SCALE: 1" = 10' 10 315 ................. 315 PLANTER STEPS PLANTER ELEVATION CONC WALL PER PLAN 310.5 310 . . . . . . . . . . . . . . . . . . 3Q9,5. \ . . . . . . . . f.--.--.--------------------------.--.-.-.- 310 EXIST INTERIOR 308.5 ----- ----- GRADE NOT TO 1 CHANGE - - - - - - - - - - - - r---J I 306.0 I 305------------30410. ... .............I.l.............................................. ..... I 305 2 II J r11,---------------J 300--- - - - - -- ......------' -----......................................................... .. 300 L----------J EXIST EXTERIOR GRADE NOT TO CHANGE 295 295 PROFILE SCALE: 1" = 10' 10 0 5 10 0 5 10 20 1 310 .......................................................... 310 PROPOSED CONC EXIST GRADE NOT TO CHANGE RETAINING WALL 305 . . . . . . . . . . . . . . 305 EXIST CMU FENCE iI r 300 .......................................... 300 ERE a I 295 ....................................................... 295 SECTION pi I I m 3 SCALE: 1" = 10' 5 0 2.5 5 10 T- 320 ........................ 320 I EXISTING GARAGE 315 . . . . . . . . . . . . . . 315 PROPOSED CONC LANDSCAPING ` RETAINING WALL WALL - - EXIST GRADE I II I I i I i 310 . . . . . . . . . . . . . . . . . �. .PROPOSED ��: . . . . . . . . . . . . . 310 GRADE EXIST CMU FENCEEXIST BLDG PILES 300.......................................................... 300 295 ........................................... 295 ;1 SECTION SCALE: 1" = 10' 5 0 2.5 5 10 320 320 EXISTING I GARAGE 315 . . . . . PROPOSED-CONC . . . . 315 RETAINING WALL EXIST GRADE PROPOSED---- GRADE 1 -I i II I II EXIST CMU 310 . . . . . . .FENCE . . . . . . . . . . . . . . . . . . . . . . . . . . 310 305 305 a � EXIST BLDG PILES 300--------------....................................... 300 U 295 . . . . . . . . . . . . . . . . 295 SECTION SCALE: 1" = 10' 5 0 2.5 5 10 4= -0- lllm�lh6 ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 09117121 1 J � Z m 0- w cf� H I= (f) = Ld w w Q aLu a N N I- n Q O O Y Q DESIGN: ZSH DRAWN: JEG CHECK: DMT JOB NO: 21117.10 DATE: 06/ 1 1 /21 RES U B Oct 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z 0 Q N J m F-- 0 0 W 00 CL 0 >- Q N Q 5 0 Z V) 0 W J W CY O Q Q 1- 00 W SHEET: S2.2 "All CORNER BARS x Q "A" ,, MAY BE SUBSTITUTED FOR ALL 90° HOOKED BARS STD 90° HOOK TYP UNO UNO, VERT CORNER BARS SHALL BE SAME SIZE TABULATED FOR MIN WALL REINF FOR THICKER WALL "A" = SPLICE LENGTH SEE NOTES, DETAILS, OR PLANS FOR Q (1) #6 VERT REQ'D REINF. ALL BARS TO BE CONT OR SPLICED PER STRUCTURAL NOTES STD 180° HOOK HORIZ CORNER BARS OF SIZE AND SPACING TO MATCH (2) #6 VERT REINF OF THINNER WALL C PLACE VERT REINF OUTSIDE EXCEPT AS OTHERWISE NOTED OR SHOWN TYPICAL CONCRETE WALL REINFORCING DETAIL SCALE: NTS PIPE TRENCH EXCAVATION PARALLEL TO FTG SLEEVES TO CLEAR PIPE 1" ALL SIDES TOF BOF o x in 2 LOWER BOF AS REQ'D PIPE TRENCH EXCAVATION PARALLEL TO FOOTING IS NOT ALLOWED BELOW THIS LINE. STEP FTG AS REQUIRED FOR THIS CONDITION Irr VO PIPES ALLOWED IN THIS REGION. LOWER =TGS AS REQ'D TYPICAL PIPE PENETRATION AT WALLS AND FOOTINGS SCALE: 1/2" = V-0" Y RETAINING WALL SCHEDULE WALL GEOMETRY WALL REINFORCING MAX "H" "D" "B" "t" "K" 'IS" BARS 'IF" BARS 3'-0" 0'-10" 1'-10" 8" 6" #4 @ 10" #4 @ 10" 4'-0" 0'-10" 2'-10" 8" 6" #4 @ 10" #4 @ 10" 5-0" 0'-10" 3'-3" 8" 12" #4 @ 10" #4 @ 10" 6-0" 0'-10" 4'-3" 8" 12" #4 @ 10" #4 @ 10" e LLJ 2 0 w z Q w Of (2) #4 BAR #4 @ 12" OC CONT HORIZ "S" BARS FOOTING DRAIN PER DETAIL 3 CONIC SLAB "S" BARS STD #4 @ 16" OC RETAINING WALL DETAIL SCALE: 3/4" = V-0" FINISHED GRADE PER PLAN 18" TOP SOIL GEOFOAM BACKFILL FILTER FABRIC "F" BARS #4 @ 12" OC SHEAR KEY PER SCHED (V U 9 C Li I AD CDI 1r'C kRS TO MATCH DOTING A REINF JRBED EARTH OR -TED FILL PER URAL NOTES T = FTG THICKNESS PER PLAN, SCHED, AND DETAILS TYPICAL STEPPED WALL FOOTING SCALE: 1/2" = V-0" 2' I "I CLR R w 0 w z H w cc (2) #5 BARS #5 @ 15" OC OR #4 @ 10" OC HORIZ "S" BARS FOOTING DRAIN PER DETAIL 3 FINISHED GRADE OR PAVING PER ARCH w 11 111 111 , i 11 I I-1 111 0 0 0 _ � [V U O 0 � —III m U #5 @ 12" OC RETAINING WALL SECTION SCALE: 3/4" = V-0" i[311 FINISHED GRADE PER PLAN 18" TOP SOIL GEOFOAM BACKFILL FILTER FABRIC 4" 0 PERFORATED PVC PIPE PER LOCAL CODES WITH 6" OF 1" MINUS GRAVEL ALL AROUND, WRAPPED IN NON -WOVEN GEOTEXTILE FABRIC. SLOPE TO DRAIN 1/8" PER V-0" MIN. TURN DOWN PERFORATIONS AS SHOWN O oqc�,Op - p Oo 0. 0° 000 °O00 1 LINE OF MAX EXCAVATION. IF SOIL IS OVER EXCAVATED, REPLACE WITH LEAN MIX CONCRETE. FIRM BEARING SOIL OR COMPACTED STRUCTURAL FILL TYPICAL FOOTING DRAIN SCALE: 1" = V-0" RETAINING WALL SCHEDULE WALL REINFORCING MAX "T" "B" "t" "D" "S" BARS "F" BARS "H" 4'-0" 0'-9" 1'-0" 8" 12" #4 @ 9" #5 @ 14" 6-0" 1'-0" 1'-10" 8" 12" #4 @ 9" #5 @ 14" 8'-0" V-0" 3'-1" 8" 12" #5 @ 12" EDGE #5 @ 12" NOTES: 1. FOUNDATION SHALL BEAR ON UNDISTURBED NATIVE SOIL PER GEOTECHNICAL REPORT. 2. NOTE THAT THE 4' AND 6' TALL RETAINING WALLS HAVE REINFORCEMENT CENTERED IN WALL. ALTERNATE HOOK DIRECTION INTO FOOTING EVERY OTHER BAR. 3. REFER TO PLAN FOR ADDITIONAL REINF REQ'D AT WALLS SUPPORTING PT SLAB. C3�J ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 09/17/21 i J � Q F— F� z CO O m V) F w a- v) r)f O 2 2 W w w � � a LLJ Q O O Y Q DESIGN: ZSH DRAWN: JEG CHECK: DMT JOB NO: 21117.10 DATE: 06/ 1 1 /21 RESUB Oct 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z 0 Q m 0 00 C 0 >_ Q O Z :m N 0 W J =) w 0 O :m Quo �- 00 w SHEET: Q W 0 Q D F_ U D � w S301