Loading...
REVIEWED revision BLD-BLD2021-1177+Structural_Analysis_or_Calculations+12.9.2021_12.18.06_PM+2563184UPSTATE engineering, inc. 22002 64TH AVE W - SUITE 2C, MOUNTLAKE TERRACE, WA 98043 SERVICESCC�UPST&COM TEL: (425) 354-4105 FAX: NOPE December 6, 2021 John Drake id drake(a-comcast.net Re: Upstate Job#1431 Site Address: 634 Walnut Revisions To Whom It May Concern: .,.,.,.,.,.,.,............................... REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT The following items were brought to our attention regarding the above project: REVISION Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. During construction, it was found that the framing configuration required that a double 2x header joist should be added in the area of interest to allow for a crawl vent to remain as shown on the attached revised sketch (clouded). 2. Galvanized Kwik-Bolts (Hilti KB) anchors are adequate for the specified application. 3. The entry door from the garage to the house can be moved from it's current location to penetrate the wall into the library/den with the use of a 4X8 header. No other structural revisions are required. Please contact our office should there be any further questions or comments. Sincerely, la Andrew Gahan, PE 12/6/2021 I +- - DBL 2x6 HEADER JOIST i LUS26-2 c\l HANGER I ) 2x6 an. 16" OC I PT 2x6 LEDAR W/ 1/2" DIAM EXP ANCHORS @ 32" OC - 3" EMBEDMENT i LL �I 'k T-A X fro V\AS UPSTATE engineering, Inc. 22002 64TH AVE W - SUITE 2C, MOUNTLAKE TERRACE, WA 98043 SERVICES@UPST8.COM TEL: (425) 3544105 FAX: JUST DON'T Wood Beam LIC#: KW-06013781, Build:20.21.10.4 DESCRIPTION: NEW DOOR HDR CODE REFERENCES Project Title: HOLTZ Engineer: amg Project ID: 1431 Project Descr: DROPPED FLOOR FOR CURBLESS SHOWER nc. Project File: 1431 GRAVITY.ec6 Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties Analysis Method : Allowable Stress Design Fb + 850.0 psi E : Modulus of Elasticity Load Combination ASCE 7-10 Fb - 850.0 psi Ebend- xx 1,300.Oksi Fc - Prll 1,300.0 psi Eminbend - xx 470.0 ksi Wood Species Hem -Fir Fc - Perp 405.0 psi Wood Grade No.2 Fv 150.0 psi Ft 525.0psi Density 26.840pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.04) 4x8 Span =3.0ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 10.50 ft, (FLR) Uniform Load : D = 0.010 ksf, Tributary Width = 4.0 ft, (WALL) Maximum Bending Stress Ratio = 0.18R 1 Maximum Shear Stress Ratio = 0.218 : 1 Section used for this span 4x8 Section used for this span 4x8 fb: Actual = 271.88psi fv: Actual = 32.77 psi Fb: Allowable = 1,436.50psi Fv: Allowable = 150.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 1.500ft Location of maximum on span = 0.000 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.005 in Ratio = 6756> 360 Span: 1 : L Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 0.008 in Ratio = 4595> 240 Span: 1 : +D+L Max Upward Total Deflection 0 in Ratio = 0 <240 n/a Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L 1 0.0078 1.511 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.926 0.926 Overall MINimum 0.630 0.630 D Only 0.296 0.296 +D+L 0.926 0.926 +D+0.750L 0.769 0.769 +0.60D 0.178 0.178 L Only 0.630 0.630