APPROVED BLD2022-0393+MECHANICAL PLAN+3.28.2022_4.28.01_PM+2766151MECHANICAL GENERAL NOTES HVAC LEGEND 1. THE TOTAL INSTALLATION SHALL COMPLY WITH ANY AND ALL REQUIREMENTS OF THE LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION INCLUDING 2018 IBC (INTERNATIONAL BUILDING CODE) WITH WASHINGTON STATE AMENDMENTS, 2018 IMC/UPC (INTERNATIONAL MECHANICAL CODE AND UNIFORM PLUMBING CODE) AND THE 2018 WASHINGTON STATE ENERGY CODE. 2. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE WILL BE REQUIRED TO WORK. 3. ALL INDICATED DIMENSIONS ARE APPROXIMATE AND ARE GIVEN FOR ESTIMATE PURPOSES ONLY. BEFORE PROCEEDING WITH THE WORK THIS CONTRACTOR SHALL CAREFULLY CHECK AND VERIFY ALL DIMENSIONS, SIZES, REQUIRED CLEARANCES AND SHALL ASSUME FULL RESPONSIBILITY FOR THE FITTING OF ALL EQUIPMENT AND MATERIALS HEREIN REQUIRED TO OTHER PARTS OF THE WORK OF OTHER TRADES. DUCT DIMENSIONS SHOWN ON PLANS ARE NET INSIDE CLEAR. 4. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT ALL OFFSETS, BENDS, SPECIAL FITTINGS AND LOCATIONS ARE NOT EXACTLY LOCATED. ALL DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE NET INSIDE DIMENSIONS. DO NOT FABRICATE DUCTWORK FROM THESE DRAWINGS. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR SUPPLYING SHOP DRAWINGS WHICH REFLECT THE PROPOSED INSTALLATION. THE SHOP DRAWINGS MUST BE APPROVED BY THE ENGINEER PRIOR TO ANY SHEET METAL FABRICATION. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ACCURATE AS -BUILT DRAWINGS AT THE COMPLETION OF THE PROJECT AND SUBMITTING THEM TO THE ENGINEER AND OWNER. 5. IN THE PREPARATION OF THESE DOCUMENTS, CERTAIN ASSUMPTIONS ARE MADE REGARDING EXISTING CONDITIONS. SOME OF THESE ASSUMPTIONS MAY NOT BE VERIFIABLE WITHOUT EXPENDING ADDITIONAL SUMS OF MONEY OR DESTROYING OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF EXISTING BUILDINGS AND/OR EQUIPMENT. THEREFORE, THE ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR ANY CHANGES OR ADDITIONAL COSTS INCURRED DUE TO EXISTING CONDITIONS. 6. THE CONTRACTOR SHALL COMPLY WITH ALL CONTRACT DOCUMENTS IN LAYING OUT HIS WORK AND EQUIPMENT. HE SHALL COORDINATE THE WORK OF THIS SECTION WITH THE WORK OF OTHER TRADES AND ALL JOB CONDITIONS. 7. THE INSTALLATION OF ACCESS PANELS OR OTHER INDICATING EQUIPMENT OR SPECIALTIES REQUIRING READING, ADJUSTMENT, INSPECTION, REPAIRS, REMOVAL OR REPLACEMENT SHALL BE CONVENIENTLY LOCATED WITH REFERENCE TO THE FINISHED BUILDING. 8. WHERE MATERIAL IS SHOWN ON THE DRAWINGS BUT NOT SPECIFIED, IT SHALL BE OF THE SAME TYPE AND QUALITY AS EXISTING MATERIAL. 9. PROVIDE MANUAL VOLUME DAMPERS AT UPSTREAM PORTION OF ALL TERMINAL AIR BRANCHES. THESE SHALL BE OF THE LOCKING QUADRANT TYPE. WHERE LOCATED OVER SLOPED OR HARD CEILINGS, PROVIDE DURO-DYNE ANGLE GEAR DRIVE OR BOWDEN CABLE CONTROL SYSTEM OR PROVIDE UNITED ENERTECH POWER/BALANCE SYSTEM. REMOTE PLATE LOCATIONS TO BE LOCATED AS DETERMINED BY ARCHITECT. 10. PROVIDE MINIMUM 1" ACOUSTICAL LINING IN ALL DUCTWORK WITHIN 10 FEET OF ALL AIR MOVING EQUIPMENT. PROVIDE DURO-DYNE FLEXIBLE CONNECTION AT ALL DUCT AT EQUIPMENT LOCATIONS. 11. DUCTS IN AN UNCONDITIONED SPACE OR EXTERIOR DUCT WORK SHALL HAVE A R-8 INSULATION. ALL EXTERIOR DUCTS SHALL HAVE INTERNAL DUCT INSULATION. 12. WHERE NOT SPECIFICALLY INDICATED OTHERWISE, ALL DUCTWORK AND EQUIPMENT SHALL BE SUPPORTED PER THE SMACNA GUIDELINES FOR SEISMIC RESTRAINT AND CURRENT APPLICABLE UNIFORM MECHANICAL CODE. 13. TESTING, ADJUSTING, AND BALANCING (TAB) OF THE AIR CONDITIONING SYSTEMS AND RELATED ANCILLARY EQUIPMENT WILL BE PERFORMED BY A CERTIFIED, INDEPENDENT THIRD PARTY, AABC AGENCY PROCURED BY THE MECHANICAL CONTRACTOR. A COMPLETE AIR BALANCE REPORT TO BE SUBMITTED TO THE ADMINISTRATIVE AUTHORITY AND TO THE MECHANICAL ENGINEER AND APPROVED PRIOR TO OCCUPANCY. 14. AIR HANDLING DUCT SYSTEMS SHALL BE CONSTRUCTED, INSTALLED AND INSULATED AS PROVIDED IN CHAPTER 6 OF 2018 IMC. 15. MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE FLAME SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE DEVELOPED INDEX NOT GREATER THAN 50 (2018 IMC SECTION 602.2). 16. UNLESS OTHERWISE STATED, MAXIMUM LENGTH FOR FLEXIBLE DUCTWORK SHALL NOT EXCEED FIVE FEET (5-0"). ALUMINUM FLEX DUCTWORK WILL NOT BE ALLOWED ON ANY PORTION OF THE DUCTWORK SYSTEM. 17. ANY SUBSTITUTION MADE BY THE CONTRACTOR THAT IS DIFFERENT FROM WHAT IS SPECIFIED ON THE DRAWINGS SHALL BE CLEARLY INDICATED ON THE SUBMITTAL AS TO ALL THAT IS BEING SUBSTITUTED. 18. THERMOSTATS SHALL BE 7-DAY PROGRAMMABLE AND SHALL COMPLY WITH THE 2018 WASHINGTON STATE ENERGY CODE. APPLICABLE CODES 1. BUILDING CODE: 2018 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS 2. PLUMBING CODE: 2018 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS 3. MECHANICAL CODE: 2018 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS 4. ELECTRICAL CODE: 2020 NATIONAL ELECTRICAL CODE (NFPA 70 - 2020) INC. ANNEX A, B, AND C 5. FIRE/LIFE SAFETY: 2018 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS 6. ADA AND ACCESSABILITY GUIDELINES (LATEST EDITION) 7. ASME A17.1 SAFETY CODE FOR ELEVATORS AND ESCALATORS 8. ENERGY: 2018 WASHINGTON STATE ENERGY CODE AIR DISTRIBUTION SCHEDULE SYMBOL I DESCRIPTION I M&MODEL NOR I FINISH I ACCESSORIES LFD LAMINAR FLOW CEILING DIFUSER "KRUGER" STAINLESS STEELMODEL 5100 OAT ALL HARD LID CEILINGS, CONTRACTOR SHALL PROVIDE FOR "MAT" CABLE DRIVEN DAMPERS. MODEL RT-150. CABLE SHALL BE ROUTED BEHIND GRILLE OPENING AND INSTALLED PER MANUFACTURER'S REQUIREMENTS. APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE SYMBOL ®o IAI ll ED r� DETAIL No. (M:: SHEET No. A M-1 EQUIPMENT ID. No. ABBREVIATIONS DESCRIPTION SQ., RECT. OR ROUND DUCT AS NOTED DUCT WITH ACOUSTICAL LINER EXIST. DUCT OR EQUIP. TO REMAIN EXIST. DUCT OR EQUIP. TO BE REMOVED FLEXIBLE DUCT CD CEILING DIFFUSER, SUPPLY CR / CE CEILING REGISTER, RETURN & EXHAUST SD/SR SIDE WALL DIFFUSER & SIDE WALL REGISTER SECTION THROUGH DUCT DUCT DOWN SQUARE TO ROUND TRANSITION DUCT ACCESS DOOR DUCT WITH TURNING VANES DETAIL REFERENCE SECTION REFERENCE EQUIPMENT REFERENCE SFD COMBINATION SMOKE / FIRE DAMPER 0 / MVD MANUAL VOLUME DAMPER OBD OPPOSED BLADE DAMPER PARALLEL DAMPER T'STAT THERMOSTAT ®D DUCT MOUNTED SMOKE DETECTOR ®S REMOTE SENSOR A.F.F. ABOVE FINISHED FLOOR CFM CUBIC FEET OF AIR PER MINUTE CFMS CFM SUPPLY CFMR CFM RETURN CFME CFM EXHAUST O.S.A. OUTSIDE AIR (N) NEW (E) OR EXIST. EXISTING 30/10 INDICATES OVAL DUCT (INCHES) 30X10 INDICATES SQUARE DUCT (INCHES) 100 INDICATES ROUND DUCT (INCHES) I P.O.0 POINT OF CONNECTION P.O.D. POINT OF DEMOLITION - MOTORIZED DAMPER - - - -DX - - - - REFR. REFRIGERANT LINES ANCHORAGE AND BRACING NOTES PIPES, DUCTS AND CONDUITS SHALL BE SUPPORTED AND BRACED PER THE 2008 SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING SYSTEMS", THE "SUPERSTRUT SEISMIC RESTRAINT SYSTEM" FOR PIPES AND CONDUITS ONLY. SHEET INDEX SHEET NUMBER SHEET TITLE M1.1 MECHANICAL LEGENDS NOTES AND SCHEDULES MD2.1 MECHANICAL FIRST FLOOR DEMO PLAN M2.1 MECHANICAL FIRST FLOOR PLAN M3.1 MECHANICAL DETAILS City Of Edmonds Building Department Work MECHANICAL- DUCT Fi DIFFUSER WORC Address 21911 76TH AVE W Owner TRANSFORM WEI-1HT LOSS Approved Date 04/06/2022 Building Official Erg Oo** r Permit Number BLD2022-0393 Mechanical installation subject to D.O.H. purview tgb I architects IDESIGN WEST ENGINEERING I MECHANICAL. ELECTRICAL. ENERGY CONSULTANTS STAMP: 1 10 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com E L ~ �� WA 0 21007747, .� GISTEg��v �SSI�NAL�� LU Z LU U ry LU ( V V) ry 0 •o Q O J 3: 00 100 LU L/) V) 0 Z r--4, Z 0 -0 0 - 0 LU N LU REV BY DESCRIPTION DATE 1 2 3 4 5 6 7 8 9 10 SHEET TITLE MECHANICAL LEGENDS NOTES AND SCHEDULES SCALE: AS NOTED DRAWN DATE APPROVED DATE SHEET NUMBER RECEIVED M 1.1 3/28/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL NOTES CONSTRUCTION NOTES MECHANICAL FIRST FLOOR DEMO PLAN I SCALE: 1/4"=1'-0° 11 tgb I architects DESIGN WEST ENGINEERING MECHANICAL, ELECTRICAL, ENERGY CONSULTANTS 110 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com STAMP: ()LE oL G OF WA Sh, <0 21007747 0GISTEg�'����v SIONAL LU Z LU U w CD ry V) ry 0 *-_o Q NO 1 3: 00 =D 01.1 j Q Q Q V) 0 c� 0 "0 Z � Z 0 -0 o> 0 � 0 w N w REV BY DESCRIPTION DATE 1 2 3 4 5 6 7 8 9 10 SHEET TITLE MECHANICAL FIRST FLOOR DEMO PLAN SCALE: AS NOTED I DRAWN I DATE 1APPROVED DATE SHEET NUMBER RECEIVED MD2.1 3/28/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL NOTES CONSTRUCTION NOTES MECHANICAL FIRST FLOOR PLAN I SCALE: 1/4"=1'-0° 11 tgb I architects DESIGN WEST ENGINEERING MECHANICAL, ELECTRICAL, ENERGY CONSULTANTS 110 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com STAMP: ()LE oL G OF WA Sh, <0 21007747 0GISTEg�'����v SIONAL LU Z LU U w CD ry V) ry 0 *-_o Q NO 1 3: 00 =D 01.1 j Q Q Q V) 0 c� 0 "0 Z � Z 0 -0 o> 0 � 0 w N w REV BY DESCRIPTION DATE 1 2 3 4 5 6 7 8 9 10 SHEET TITLE MECHANICAL FIRST FLOOR PLAN SCALE: AS NOTED I DRAWN I DATE 1APPROVED DATE SHEET NUMBER RECEIVED M2.1 3/28/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 101 - 171 - 14 111 - 181 - 15 121 - 191 - 16 FOR CONN. TO STRUCT, SEE STRUCTURAL DRAWINGS 1"x3"L 16 GA. BENT CLIP--,,e SECURED TO CD/CR W/#10 SMS TYP.(2) EACH CD/CR AT DIAG. CONTRACTOR TO CONNECT FLEX TO DUCT COLLAR OF PLENUM. COLLAR W/ (3)#10 SMS W/ APPROVED SEALANT 12 GA. WIRE GWB CEILING NOTE: SEAL ALL JOINTS & CONNECTIONS AIR TIGHT W/ APPROVED SEALANT FOR CONNECTI( STRUCTURE-SI STRUCTURAL DRAWINGS HANGER STRAP SEE SCHEDULE BELOW 3/8"o MACHINE BOLT > 2" WIDE x 22 GA. / HANGER STRAP LONG RADIUS TURN - NO KINKS LAMINAR FLOW DIFFUSER AIR DISTRIBUTION 2x2xl6 GA. DIAGONAL 1" BRACE PER SMACNA GUIDELINES FOR SEISMIC RESTRAINT. IF DISTANCE BELOW SUPPORTING STRUCTURAL MEMBER IS LESS THAN 12", DIAGONAL BRACE MAY BE OMITTED ROUND DUCT - SEE PLANS FOR SIZE DUCT STRAP - SAME AS HANGER STRAP NOTE: PER 2006 SMACNA HVAC DUCT CONSTRUCTION STANDARDS AND 2019 CMC SECTION 602.1 & 603 HORIZONTAL HANGER STRAP SCHEDULE DUCT SIZE HANGER SIZE MAX. SPACING MATERIAL UP THRU 20" 1" x 22 GA. 10'-01, O/C G.I. STEEL 21" TO 40" 1" x 20 GA. 10'-01, O/C G.I. STEEL DUCT SIZE HANGER SIZE MAX. SPACING MATERIAL UP THRU 10" 2" x 18 GA. 12'-0" O/C G.I. STEEL 11" TO 20" 2" x 16 GA. 12'-0" O/C G.I. STEEL 21" TO 40" 1/8" STEEL X 1-1/2" 12'-0" O/C G.I. STEEL DUCT SUPPORT - ROUND 21 J tgb I architects DESIGN WEST ENGINEERING MECHANICAL. ELECTRICAL. ENERGY CONSULTANTS STAMP: 1 10 James St., Suite 106 Edmonds, WA 98020 Phone: 425.458.9700 Email: cadd@designwesteng.com O L ~7vy- A 'II 21007747 IST &g���v %0IOWAL LU z LU U rLU V V) 004 •o Q O LU00 L/) o V) 0 ,o z r--4,z 0 —0 01-1 o �o LU N LU REV BY DESCRIPTION DATE 1 2 3 4 5 6 7 8 9 10 SHEET TITLE MECHANICAL DETAILS SCALE: AS NOTED I DRAWN I DATE 1APPROVED DATE SHEET NUMBER RECEIVED 3/28/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M3.1