Loading...
REVIEWED RESUB 1 BLD2022-0853+Structural_Calculations+7.14.2022_8.57.31_PM+2991216BLD2022-0853 July 11, 2022 Puget Sound Solar 805 Rainier Avenue South Seattle, WA 98144 TEL: (425) 260-1425 Attn.: Lyudmila Arseniy, Re: Job # 2022-07618: Edmonds 99 P78 structural ENGINEERS REVIEWED BY CITY OF EDMONDS € BUILDING DEPARTMENT RESUB Jul 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT The following calculations are for the Structural Engineering Design of the Photovoltaic Panels located at 23400 Highway 99, Edmonds, WA 98026. If you have any questions on the above, please feel free to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA EXPIRES 08/0Z/2023 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 i 916.961.3960 916.961.3965 . www.pzse.com experience I integrity I Empowerment RESUB Jul 15 2022 ■U-BUILDER PROJECT REQQPOEK�oFEDMONDS ■ RSU!1XMENTSERVICES ■■■ PARTMENT PROJECT TITLE PROJECT ID CREATED ROOFMOUNT RM10 5E6A6918 Oct. 21, 2021, 12:26 p.m. NAME Edmonds 99 Designed by sayali@pugetsoundsolar.com ROOFMOUNT RM10 ADDRESS 23400 HIGHWAY 99 REC SOLAR CITY, STATE Edmonds, WA 19 -REC365TP4 Black MODULE REC SOLAR REC365TP4 Black 373.26 ftz 6.94 KW NOTE: Installation of the project is intended to happen within the year of project designed in UBuilder. If it's past one year please rerun the design or contact Unirac Engineering Services. BILL OF MATERIALS LEGEND: ■ Base System Part ■ Accessory PART SUGGESTED NUMBER PARTTYPE DESCRIPTION QUANTITY QUANTITY User Ballast Block Ballast Block 127 127 Supplied 310710 Ballast Bay RM Ballast Bay 10 Degree 58 58 310760 RM Roof Pad RM Roof Pad 64 64 310750 Module Clip RM Module Clip 175 175 310751 RM Hex Bolt RM Hex Bolt (Module Clip) 175 175 This design is to be evaluated to the product appropriate Unirac Code Compliant Installation Manual which references International Building Code 2009, 2012, 2015, 2018 and ASCE 7-05, ASCE 7-10, ASCE 7-16 and California Building Code 2010, 2016. The installation of products related to this design is subject to requirements in the above mentioned installation manual. Page 2 of 9 DETAILED PARTS DESCRIPTION RESUB Jul 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES Q-115YPARTMENT Ballast Block UserSupplied Ballast Block 127 Standard 4x8x16 inch cap blocks. Nationwide availability. Please confirm the weight of your IV ballast block as this will affect the total blocks required for your installation. Ballast Bay 310710 RM Ballast Bay 10 Degree 58 Aluminum ballast bay attaches to north and south module edges (for 10 degree tilt installations) and provides ballast placement location. RM Roof Pad 310760 RM Roof Pad 64 TPE 201-73 BK Santoprene Roof Pad. PLEASE NOTE: Depending on your roof type and seismic conditions, some quantity of roof pads may be required. These will be listed separately on your bill of materials. Module Clip 310750 RM Module Clip 175 Aluminum clip fastens module frame to ballast bay and provides bonding path from module to bay to module. RM Hex Bolt 310751 RM Hex Bolt (Module Clip) 175 Hex bolt with integrated locking patch. NOTE: Installation of the project is intended to happen within the year of project designed in UBuilder. If it's past one year please rerun the design or contact Unirac Engineering Services. Page 3 of 9 ENGINEERING REPORT Plan review AVERAGE PSF TOTAL NUMBER OF MODULES TOTAL KW TOTAL MODULE AREA TOTAL WEIGHT ON ROOF RACKING WEIGHT MODULE WEIGHT BALLAST WEIGHT MAX BAY LOAD (DEAD) Loads Used for Design BUILDING CODE BASIC WIND SPEED GROUND SNOW LOAD SEISMIC (Ss) ELEVATION WIND EXPOSURE M RI RISK CATEGORY VELOCITY PRESSURE, QZ Loads Determined by Zip CITY, STATE BASIC WIND SPEED GROUND SNOW LOAD 8.49 psf 19 6.94 KW —602 ftZ 5105 Ibs 203 Ibs 838 Ibs 4064 Ibs 208 Ibs ASCE 7-16 110.00 mph 25.00 psf 1.310 310.00 ft B 50 22.61 psf 98026 Edmonds, WA 93.00 mph 20.00 psf Inspection PRODUCT MODULE MANUFACTURER MODEL MODULE WATTS MODULE LENGTH MODULE WIDTH MODULE THICKNESS MODULE WEIGHT BALLAST BLOCK (CMU) WEIGHT MAX BLOCKS PER NORTH BAY MAX BLOCKS PER NON NORTH BAY BUILDING HEIGHT ROOF TYPE PARAPET HEIGHT RISK CATEGORY RESUB Jul 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ROOFMOUNT RM10 REC SOLAR REC365TP4 Black 365 watts 69.10" 40.94" 1.20" 44.10 Ibs 32.0 Ibs 6 4 65.00 ft EPDM > 1 Array Height (> 12 inches) 11 Page 4 of 9 RESUB Jul 15 2022 Roof Area 1 - Array1 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT AVERAGE PSF 8.49 psf MINIMUM SEISMIC SEPARATION (UNATTACHED ARRAYS) ARRAY TO ARRAY: 12.6" TOTAL NUMBER OF MODULES: 19 TO FIXED OBJECT ON ROOF: 25.2" TOTAL KW: 6.94 KW TO ROOF EDGE WITH QUALIFYING PARAPET: 25.2" TOTAL AREA: 602 ft2 TO ROOF EDGE WITHOUT QUALIFYING PARAPET: 50.4" TOTAL WEIGHT ON ROOF: 5105 lbs MAX ARRAY (SEISMIC) (FOR UNATTACHED ARRAYS) RACKING WEIGHT: 203 lbs MAX NUMBER OF NORTH -SOUTH ROWS: 6 MODULE WEIGHT: 838 lbs MAX NUMBER OF EAST -WEST COLUMNS: 14 BALLAST WEIGHT: 4064 lbs *See ASCE 7-16 Section 13.6.12 for more details Page 5 of 9 RESUB RM10 U-BUILDER PRODUCT ASSUMPTIONS RM10 - Ballasted Flat Roof Systems Jul 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Limitations of Responsibility: It is the user's responsibility to ensure that inputs are correct for your specific project. Unirac is not the solar, electrical, or building engineer of record and is not responsible for the solar, electrical, or building design for this project. Building Assumptions 1. Risk Category III 2. Building Height < 50 ft 3. Building Height > 50 ft: only where (longest length of building x building height)A0.5 < 100 ft 4. Roof Slope >- 00 (0:12) and < 30 (5/8:12) for Seismic Design Category C, D, E and F. For low seismic regions Seismic Design Category A and B (provided Array Importance factor = 1.0), Roof Slope >- 0° (0:12) and < 7° (1 1 /2:12). 5. Roofing Material Types: EDPM, PVC, TPO, or Mineral Cap 6. Surrounding Building Grade: Level Ballast Blocks The installer is responsible for procuring the ballast blocks (Concrete Masonry Units - CMU) and verifying the required minimum weight needed for this design. CMU should comply with ASM standard specification for concrete roof pavers designation (C1491 or C90 with an integral water repellent suitable for the climate it is placed. It is recommended that the blocks are inspected periodically for any signs of degradation. If degradation of the block is observed, the block should immediately be replaced. The CMU ballast block should have nominal dimensions of 4"x8"xl6". The actual block dimensions are 3/8" less than the nominal dimensions. Ballast blocks should have a weight as specified for the project in the "Inspection" section of this report. Design Parameters 1. Risk Category I to III 2. Wind Design a. Basic Wind Speed: 85-120 mph (ASCE 7-05)/110-150 mph (ASCE 7-10)/90-180 mph (ASCE 7-16) b. Exposure: B, C or D (ASCE 7-05/ASCE 7-10) c. 25 year Design Life/50 year Design Life for ASCE 7-16 d. Elevation: Insertion of the project at - grade elevation can result in a reduction of wind pressure. If your project is in a special case study region or in an area where wind studies have been performed, please verify with your jurisdiction to ensure that elevation effects have not already been factored into the wind speed. If elevation effects have been included in your wind speed, please select 0 ft as the project site elevation. e. Wind Tunnel Testing: Wind tunnel testing coefficients have been utilized for design of the system. 3. Snow Design a. Ground Snow Load: 0-80 psf (ASCE 7-10/ASCE 7-16) b. Exposure Factor: 0.9 c. Thermal Factor: 1.2 d. Roof Snow Load: Calculation per Section 7.3 (ASCE 7-05/ASCE 7-10/ASCE 7-16) e. Unbalanced/Drifting/Sliding: Results are based on the uniform snow loading and do not consider unbalanced, drifting, and sliding conditions 4. Seismic Design a. Report SEAOC PV1-2012/ASCE 7-16 SECTION 13.6.12 - Structural Seismic Requirements and Commentary for Rooftop Solar Photovoltaic Arrays b. Seismic Site Class: A, B, C, or D (ASCE 7-05/ASCE 7-10/ASCE 7-16) c. Importance Factor Array (Ip): 1.0 d. Importance Factor Building (le): 1.0 e. Site Class: D Properties 1. Bay Weight: -3.5 Ibs 2. Module Gaps (E/W) = 0.25 in 3. Bays: North row bays overhang the module by --19.5 inches. Module Properties 1. Module return flange: Minimum of 0.9in (when using 1-3/4 in. clip bolts) is required. 2. Module return flange: Minimum of 0.65in (when using 2 in. clip bolts) is required. Page 6 of 9 RESUB Testing 1. Coefficient of Friction 2. Wind Tunnel 3. U L 2703 4. Component Testing (Bay and Clamp) Setbacks For the wind tunnel recommendations in U-Builder to apply, the following setbacks should be observed/followed for U-Builder wind design: Jul 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. Modules should be placed a minimum of 3 feet from the edge of the building in any direction. 2. If the array is located near an obstruction that is 3.5 feet wide and 3.5 feet high or larger, the nearest module of the array must be located a distance from the obstruction that is greater than or equal to the height of the obstruction. Exception: When using ASCE 7-16 Building Code and using the obstruction feature in the module editor to accurately model the size and location of obstruction. 3. Installations within the setbacks listed above require site specific engineering2 4. The setbacks above are for wind. High seismic areas, fire access isles, mechanical equipment, etc., may require larger setbacks than listed above for wind. Site Specific Engineering Conditions listed below are beyond the current capabilities of U-Builder. Site specific engineering is required. 1. Wind designs for a project design life exceeding 25 years1/ASCE 7-16 2. Building assumptions and design parameters outside of U-Builder assumptions2 3. Attachments2 4. Risk Category III or IV projects (U-Builder can be adjusted for the correct wind, but not the seismic or snow design)2 5. Wind tunnel testing reduction factors are not permitted by the Authority Having Jurisdiction (AHJ)3 6. Seismic designs that fall outside SEAOC PV1-2012/ASCE 7-16 SECTION 13.6.12 recommendations (>3% roof slope, or AHJ's that require shake table testing or non -linear site -specific response history analysis)3 7. Signed and sealed site -specific calculations, layouts, and drawings3 Notes: 1 Please contact info@unirac.com. 2 Please contact EngineeringServices@unirac.com for more information. 3Please contact Theresa Allen with PZSE Structural Engineers at theresa@pzse.com. These items will require direct coordination with PZSE to complete the requested services. Page 7 of 9 RESUB Jul 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES NOTE: Installation of the project is intended to happen within the year of project designed in UBuilder. If it's past one year please DEPARTMENT rerun the design or contact Unirac Engineering Services. INSTALLATION AND DESIGN PLAN Roof Area 1 / Roof Area 1 - Array 1 1 2 3 4 11111:144011 9 2 3 4 5 6 - Module Standard corner bay with CMU block count USupplemental bay with CMU block count NOTE Blocks above with values greater than 4 require extra ballast bays, except north -most bays which require extra bays for values greater than 6. The proper number of bays are provided in the Bill of Materials. The installer must install these extra bays as near to the indicated location as possible. Install 2 roof pads to every primary bay. Layout Dimensions NS DIMENSION - 21.56 ft EW DIMENSION - 34.68 ft Page 8 of 9 ROW MODULES BAYS BALLAST BLOCKS (CMU) BALLAST WEIGHT(LBS) 1 6 13 37 1184 2 6 13 28 896 3 4 13 28 896 4 3 12 21 672 5 0 7 13 416 RESUB Jul 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Page 9 of 9