Loading...
BLD2022-1387_Site_Plan_10.11.2022_2.17.40_PM_3158456Equipment Summary Modules: (27) REC 405W Inverter(s): (1) SolarEdge 1000OH-US Racking: Ironridge XR100 Table of Contents: Cover Page Al Site Overview A2 Roof Layout E1 Single Line E2 Electrical Calculations G1 Roof As Built G2 Electrician As -Built G3 Micro/optimizer map G4 Placards G5 Equipment BOM General Notes: Additional Electrical Work: Net Met Site A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Q o 't 4- N o O °'rn�rn 0 p l0 U Q .. 0 rn L � V U 0 o -0�� 0- vi 0 U o o 0 L Ln � ,i E a M _0 O1 W 0 1_1 REVISIONS Rev. #: I Date: Designed by: Thomas N Project Manager: Diallo Josey (253) 267-4600 Current Date:Sep 28, 2022 Cover Page N m ❑ ❑ 0 MSP Net Meter, AC Disconnect, Inverter, Customer Owned Production Meter Attachment Detail Side View (Portrait) FLASHING AS REQUIRED TO SEAL ROOF MINIMUM (1) 5/16 X 4.75 LAC BOLT EMBEDDED 2" MINIMUM CENTER ON ROOF FRAMINC PV MODULE, BY OTHERS IRONRIDGE RAIL (E) COMPOSITION SHINGLE ROOF IRONRIDGE FLASHFOOT2 (E) ROOF FRAMING Modules not to exceed height of existing ridge — — — — — — — — — — — — — — — — — — — — — — �181I� ,6,I Building height I Manufactured trusses, 24" O.C. (sample) Attachment point layout for array. 72" OC Max. &*41./��. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Q o � 't 4- N o 06 o '..J pl0 UQ .. 0 rn L � V U 0 o -0 0- �i v -0 0^� Uoo 0 a M 0 p1 W 0 ,--1 REVISIONS Rev. #: I Date: Designed by: Thomas N Project Manager: Diallo Josey (253)267-4600 Current Date:Sep 28, 2022 Al Site Overview Required Setbacks from Ridge: 18" "Alf r � ��B" Maximum Mount Spacing: 72" Comp Roof Type: Roof Slope: 180 Array Tilt : Flush Array Azimuth(s): 910,1810,271° Roof Area: 2824ft2 Array Area 538ft2 Array to Roof Coverage 19% ***Roof Attachments/ Fastners; see pg. G5 Equip. BOM * * * L — J Net Meter *--\ Module and Rail Selection Guide REC 405w Alpha BoB 40 x 71.7 Clamp Zone "A" 4.0-9.8" Clamp Zone "B" 8.2-23.8" Mods per Row Rail typel+ rail type2 (5)Portrait, (3)rows (2)14', (2)split 14' (3)Portrait, (2)rows (2)14', (2)Portrait, (3)rows (2)split 17', NA,����i A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Q � O 't 4- N o 0 p U Q .. 0 a L V U 0 o -0 0- � v i -0 0^ U oN o 0 L Ln ..o E a M -0 p1 W 0 ,--1 REVISIONS Rev. #: I Date: Designed by: Thomas N Project Manager: Diallo Josey (253)267-4600 Current Date:SeD 28. 2022 A2 Roof Layout I I I I C I I _ I String 1 z 11 modules + o String 2 U � o 8 modules + String 3 8 modules + AA A 0 Equipment Schedule I Line L� O Load I Located less than 10' I from net meter and S I less than 10' from tap I I �L--------- 5 Customer Owned Production Meter Ref. Category Equipment QTY 1 Modules REC 405w Alpha BOB 27 2 Optimizers P485 SolarEdge Optimizer 27 3 Jbox Jbox 5 41 Inverters Solar Edge SE10000H 1 5 MeterBase MeterBase-125A 4 Jaw w/ 3.5" AWCAP 1 Meter Landis Gyr EA110000-OP29 240V 1 6 Disconnect 60A 240V 2 Pole I Heavy Duty, Fuse, Lockable 1 DisconnectFuse FLNR - 60 A Fuses for Disconnect (qty 1 /pole) Monitoring SolarEdge Consumption Monitoring (2p2OA breaker+CT's) 1 0 Conductor Schedule 0 L---.4 #6 GEC 1 Neutral Bar w/ bonding jumper Supply Side Connection 705.11 (Existing) Main Service Panel (1ph 240V Service) Main Breaker: 200A Bus Rating:200A O = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 Service entrance conductors 4/0 XHHW-2 (L1 & L2) 2/0 XHHW-2 (N) Inverter Specs Watts � Output � AC Voltage # of Inverters OCPD SolarEdge SE100001-1 10000 42 240 1 60 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w Imp Vmp Voc Isc REC 405w Alpha BOB 405 9.56 42.4 48.9 10.14 Temp. Adjusted 0 0 37 52.7 0 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop Volt. Drop (total) A (2)#10 CU, (1)#6 EGC, PV Wire 60OV, AIR 50 18.75A 400V 0.35% 1.04% B (6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) 50 18.75A 400V 0.35% C (2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 52.5A 240V 0.17% D (2)#6 CU, (1)#6 N, THWN-2, 1"PVC(min) 10 52.5A 240V 0.17% General Notes: THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Q O It a--' N O o O� pl0 UQ V o -� ,Z U-) ui . > M O U0N0 0 aM 70 p1 LU O REVISIONS Rev. #: IDate: Utility: Snohomish PUD IDesigned by: Thomas N 1. EGC Where exposed to physical damage will be #6AWG Project Manager: Bare CU Diallo Josey 2. If installing conduit on the roof, maintain greater than 7/8" (253) 267-4600 above the surface 3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Current Date:Sep 28, 2022 Disconnect 4. For supply side taps, a #6 GEC (min.) will be run separately from the disconnect and connected to the grounding electrode E1 Single Line with an irreversible crimp PV Electrical Calculations Inverter Specs Watts Output AC - Voltage # of Inverters OCPD Total AC Comb. EGC AC W (A) out.(A) OCPD Solar Edge SE10000H 10000 42.00 240 1 60 42.0 60 #10 r Ampe ****N/A**** 0 0.00 0 0 0 ****N/A**** 0 0.00 0 0 0 Module Specs at Watts IMP Vmp Voc Isc Temp. Coef V(oc) DC Volt REC 405w Alpha BoB 405 9.56 42.4 48.9 10.14 -0.24 #10 Max V( Max, Temp. Adjusted 37.0 52.7 Optimizer? P485 SolarEdge Optimizer Max current output: 15A, Max Voltage: 480V Equipment Solar Edge SE10000H ****N/A**** ****N/A**** Mppt Input 1 1 2 1 3 1 1 2 3 1 1 2 3 Module REC 405w Alpha BoB ****SELECT**** ****SELECT**** # Modules per String 11 8 0 0 0 0 0 0 0 # Strings 1 2 0 0 0 0 0 0 0 # of Mods per group 11 16 1 0 0 0 0 0 0 0 # of Mods/inverter 27 0 0 # of Inverters 1 0 0 Total # of Modules 27 Ref. Conductor Description nce Dist-a1 AL CU A String to Jbox 50 CU B Jbox to Inverter 50 Cu C Inverter to Disconnect 10 Cu D Disco. to Interconnect 10 Cu E F G H Array Specs (Adjusted for Temperature) Inverter ilppt Input -age (Imp) age (Vmp) Solar Edge SE10000H 1 2 3 11.14 8.10 0.00 400.0 400.0 0.0 ****N/A**** 1 2 3 0.00 0.00 0.00 0.0 0.0 0.0 ****N/A**** 1 2 3 0.00 0.00 0.00 0.0 0.0 0.0 iltage(DC) 480.0 480.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 imps (DC) 15.00 15.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Max Array Power(STC): 10.935 kW DC Max Continuous AC Power: 10kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI lowed 40 PV OCPD Device Used 60 Tap or Breaker? Tap Site Conditions ASHRAE Site: Seattle Low Temp (°F) 19 High 2%Temp (°F) 84 High 0.4%Temp (°F) 91 Wire ja (QTY) Phase Neutral Neutral EGC (AWG) Wire Type Conduit Min. Conduit 90°C Rating Temp Correct. Fill Derate Derated 7YC Current Operating Voltage Conductors AWG (QTY) Type Ampacity Rating @125% Voltage Drop #10 2 N/A N/A #6 PV Wire 600V AIR N/A 40 1 100% 40.00 35 18.8 400 0.35% #10 6 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 18.8 400 0.35%o #6 2 #8 1 #10 THWN-2 EMT 0.75" 75 1 100% 75.00 65 52.5 240 0.17% #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 65 52.5 240 0.17% �11P%. .4 A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR ND ITS RECEPTOR. POSSESSION DOES NOT )NFER ANY RIGHT IN OR LICENSE TO USE IT -�R THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS J RAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Q O � 4- fV O CO �O)U) oo OI IO 0 p � U Q .. C L 3:O V U 0 -0 Q U-) vi __ ID M 0^�> UOo 0 L Ln E a M _0 w 0 REVISIONS Rev. #: I Date: Designed by: Thomas N Total Voltage Drop:1.04% Project Manager: Diallo Josey (253) 267-4600 Current Date:Sep 28, 2022 E2 Electrical Calculations Typical Placards Custom Placards A) NEC 2020 690.13 & 691.15 B) NEC 2020 705.12 (13)(3)(2) C) Utility Requirement D) Utility Requirement (Commercial Only) D) A&R Solar Requirement (Residential Customer -Owned) E) A&R Solar Requirement * if combiner used F) NEC 2020 690.13 (B) I) NEC 2020 690.31 (D)(2) K) NEC 2020 690.13 (B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFFPOSITION TO SOLARAELS PV PANELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY L) NEC 2020 690.56 (C) *Used with Micro Inverters or DC Optimizers O) A&R Solar Requirement * if multiple inverters IAWARNING DUAL POWER SOURCE] SECOND SOURCE IS PHOTOVOLTAIC SYSTEM P) NEC 2020 705.12(C) & 690.59 R) AHJ Requirement * if combiner used S) NEC 2020 230.85(1) T) NEC 2020 230.85(3) NEC 690.54 NEC 690.53 NEC 690.54 PLACARD ti,=CS L Ti Letter Height: 1/8" Inverter Maintain 1/4" border 1 Interconnection Point Red / White Letter Height: 1/8" Maintain 1/4" border 1 Solar Edge SE10000H Red / White Letter Height: 1/8" (1) for each Maintain 1/4" border 1 Disconnect or upstream Red / White loadcenters. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Q 0 � 't 4- N O 0 p U Q .. 0 a L V U 0 O -0�� 0- vi -0 0^� U 0 0 0 L Ln � ,i E aM LU O r_1 REVISIONS Rev. #: I Date: Designed by: Thomas N Project Manager: Diallo Josey (253) 267-4600 Current Date:Sep 28, 2022 G4 Placards J) NEC 2020 690.56 (C)(2) Category Equipment QTY Notes Solar Equipment Modules REC 405w Alpha BOB 27 Optimizers P485 SolarEdge Optimizer 27 Inverters Solar Edge SE10000H 1 Monitoring Solar Edge Consumption Monitoring (2p20A breaker+CTs) 1 Electrical Equipment Jbox Jbox 5 MeterBase MeterBase-125A 4 Jaw w/ 3.5" AWCAP Meter Landis Gyr EA110000 )P29 240V Disconnect 60A 240V 2 Pole I Heavy Duty, Fuse, Lockable DisconnectFuse FLNR - 60 A Fuses for Disconnect (qty 1 /pole) Solar Racking Iron Ridge Racking BOM Description XR100 Black,17' XR100 Black,14' Kit, XR100 Bonded Splice BOSS Universal Module Clamp, Black Stopper Sleeve 30mm Grounding Lug, Low Profile Square -Bolt Bonding Attachment Hardware 1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt End Caps, 10 sets(package) XR100 IronRidge Flash Foot2, Black (Spacing: 72") Fastener: 5/16 x 4.75" Lag(Included) (1 /mount) System Weights RackingWeight(lbs) Total Weight(lbs) Weight/Attachment(lbs) DeadLoad(PSF) QTY 1� 1 1 DH222NRK 3 13 6 70 32 8 51 27 2 51 250 1465 28.7 2.73 A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Q O � 4- fV O O � �O�)Q) oo 0 p�O UQ .. o 0) L V U C) O Q vi > M .IV O_�e U0 0 L Ln .. E a M -v w O REVISIONS Rev. #: I Date: Designed by: Thomas N Project Manager: Diallo Josey (253)267-4600 Current Date:SeD 28. 2022 G5 Equipment BOM