Loading...
REVIEWED BLD2021-0173+Manufacturer_Specifications_and_Installation_Instructions+1.29.2021_12.04.29_PM+2021032Carrier RECEIVED Jan 29 2021 SUBMITTAL CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project GRE Edmonds 99 Date BLD2021-0173 Wednesday, January 27, 2021 Contractor Emerald Aire REVIEWED BY CITY OF EDMONDS 5t Unit Project: GRE Edmonds 99 01/27/2021 Prepared By: 12:54PIV 5t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.55 Page 3 of 12 Unit Report For 5t Unit Project: GRE Edmonds 99 01/27/202 Prepared By: 12:54PN Unit Parameters Dimensions (ft. in.) & Weight (lb.) *** Unit Model: ........................ 48FCDA06A2A5-OAOAO Unit Length: ......................................... 6' 2.375" Unit Size: ................................................ 06 (5 Tons) Unit Width: ......................................... 3' 10.625" Volts -Phase -Hertz: ..................................... 208-3-60 Unit Height: ......................................... 2' 9.375" Heating Type: ..................................................... Gas Total Operating Weight:...................... 626 lb Duct Cfg:... Horizontal Supply / Horizontal Return Low Heat Weights and Dimensions are approximate. Weight Standard One Stage Cooling Models does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size: ..................................................... 1/2 Condensate Drain Line Size: .............................. 3/4 Return Air Filter Type: ........................... Throwaway Return Air Filter Quantity: ....................................... 2 Return Air Filter Size: .............................. 16 x 25 x 2 Unit Configuration Direct Drive - EcoBlue - Medium Static AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCDA06A2A5-OAOAO Rooftop Unit 2 Base Unit Direct Drive - EcoBlue - Medium Static None Accessories ECH-SRT12CA-D2DH LOW LEAK - Horizontal EconoMi$er X with solid-state W7220 controller 2 Packaged Rooftop Builder 1.55 Page 4 of 12 Certified Drawing for 5t Unit Project: GRE Edmonds 99 01/27/2021 Prepared By: 12:54P NOTES: UNIT J K 1. DIMENSIONS ARE IN INCHES, DIMENSIONS 48FC**04 33 3/8 18 5/8 IN I ] ARE IN MILLIMETERS. [8471 [4727 2. & CENTER OF GRAVITY 48FC**05 33 3/8 [847] 14 [317] 7/8 48FC**O6 33 3/8 1 4 7/8 3. � DIRECTION OF AIR FLOW [847] [317] 48FC**07 41 3/8 18 5/8 4. ALL VIEW DRAWN USING 3RD ANGLE [10511 I4721 3-3/4 I95I CONDENSER COIL OPTIONAL - FACTORY INSTALLED CONVENIENCE OUTLET 46-5/8 [1186] LEFT 33-3/8 18481 32-118 ` ECONOMIZER HOOD I817I (OPTIONAL) [65278 6 1 I407I 5-5/ RETURN AIA C 10-7/8 DID ETURN 277] 44-1 /8 29 -1 /2 [1120.9] Y E ALA. [748] CONDENSATE 17-3/4 Z DRAIN OPENING [451] 0100. IN BASEPAN SUPPLY 26-5/8 • AIR 16751 SUPPLY 4 [3AIR 69] 12-1 /2 11.1/2 SEE THRU THE % [318] I293I BASE CHART 10-1/8 2X 1 23-3 /4 6-114 12561 I603I3/4 � [81] [158] 1101] FLUE I30718 GOD 2% 25 18-3/8 16351 14661 2X 4-5/8 TOP CONNECTION SIZES A 1 3/8" 1351 DIA FIELD POWER SUPPLY HOLE B 2" 1501 DIA POWER SUPPLY KNOCKOUT C 1 3/4" 1511 DIA GAUGE ACCESS PLUG D 7/8" 1221 DIA FIELD CONTROL WIRING HOLE E 3/4"-14 NET CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION G 2 112 " 1641 DIA POWER SUPPLY KNOCKOUT THRU-THE-BASE CHART THESE HOLES • * *• •008AO0 11A11 USE • •� ■ * 1 [1181 E STD. CONDENSATE 10-7/B 1 ELECTRICAL DRAIN [275] I25I DISCONNECT LOCATION - _ ---!!! T FILTER A, B,G OPTIONAL CONTROL BOX FACTORY ACCESS PANEL 17-3/8 25-3/4 INSTALLED INDOOR BLOWER I441I I653] DISCONNECT ACCESS PANEL SUPPLY AIR RETURN AIR HANDLE 11-1/8 ' u 19-1 /2 F [302] X1 21-1/4 [539] OUTSIDE [494] - Q AIR [I. [28714 1 ( 0 QQ" HANDLE 5-3/4 6-318 7 5-3/4 - 30-118 17661 B-3/8 12141 I746I [161] " "1 26-7/8 L1461 1682] 74-3/8 31 [786] BAROMETRIC I1889] RELIEF FRONT SUPPLY aw AIp AETUAN RIGHT AIN ITC CLASSIFICATION SHEET DATE SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 1 OF 3 O9/O7/18 06/22/18 COOLING WITH GAS HEAT 48TC003093 A Packaged Rooftop Builder 1.55 Page 5 of 12 Certified Drawing for 5t Unit Project: GRE Edmonds 99 01/27/2021 Prepared By: 12:54P N STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER B .���llil,�/l/�ii m1111111111i, CORNER D I 1 11 CORNER C X TOP FRONT C[dY Jer IHSELUPI?YERXOIIS of R THAT THE CONTENTS III LL N IWYW T�eb� WITHOUT WRITTEN CONSENT. R12 112 WITH ECONOMIZER BAC� BACK 13181 . WITHOUT ECONOMIZER ECONOMIZER HOOD OPTIONAL DOOR (OPTIONAL) SWING 0 RIGHT —+ LEFT 74-5/8 Hass[ FRONT L----- 1_ NOTES: 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. CLEARANCE SERVICE WITH: SERVICE WITH: OPERATING SURFACE CONDUCTIVE BARRIER NONCONOUCTIVE BARRIER CLEARANCE FRONT 48 11219mml 36 1914mml 18 1457mmI LEFT 48 11219mm] 42 11067mml 18 1457mmI BACK 48 11219mmI 42 11067mml 18 1457mmI BACK W/HOOD 36 1914mml 36 1914mml 18 1457mmI RIGHT 36 1914mml 36 1914mml 18 1457mmI TOP 72 11829mm] 72 11829mml 72 11829mml ITC CLASSIFICATION SHEET DATE SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 2 OF 3 09/O1/18 06/22/18 COOLING WITH GAS HEAT 48TC003093 A Packaged Rooftop Builder 1.55 Page 6 of 12 Certified Drawing for 5t Unit Project: GRE Edmonds 99 01/27/2021 Prepared By: 12:54P FILTER ACCESS PANEL COME. COIENSER TOO OIL PANEL INDOOR 1 BACK LEFT C[dYTIEY INSEcTV 1C.TENT1 1-1. THAT THE CONTENTS NSEN N INYW T�eb�� WITHOUT WRITTEN CONSENT. 71-1/8 ] BASE R (INSIDE THE BASE RAIL 8 SKIRT) X* 41 -1/4 (INSIDE THE046BAS5]E RAILS( INSIDE BASERAIL DIMENSIONS 2X 1-7/8 BOTTOM 1481 JL z % 1-3/8 2X 1 3-1 /4C 36] [25] 82] 2% 3/4 3-7/8 [18] DETAIL C 1991 TYP 4 PLCS INDOOR BLOWER ACCESS PANEL EE DETAIL C 0 3-114 �I 59-3/8 - 2-3/8 I82.0] [1509.0] [61.5] 7-1/8 TYP CURB FRONT 1180.71 WIDTH DATE SUPERCEDES 48FC 04-03 SINGLE PACKAGE ELECTRICAL RE' /A711A _ 0/,A COOLING WITH GAS HEAT 48TC003093 A Packaged Rooftop Builder 1.55 Page 7 of 12 SUBMITTAL Economizer - Ultra Low Leak, dedicated horizontal, W7220 controller or actuator only, single or two speed units adjustable dry bulb enthalpy, dual dry bulb or dual Y� g P � J Y � PY� Y enthalpy, painted O/A hood with aluminum filter, Barometric relief hood, All necessary DATE: 4/19 panels and hardware included SUBMITTED TO: Carrier COMPANY: MicroMetl DRAWN BY: ABC JOB NAME: WEIGHT: NOTES: 1 of 2 FEATURES: • PAINTED CONSTRUCTION • DEDICATED HORIZONTAL ECONOMIZER • ECONOMIZER IS CLASS lA CERTIFIED • RELIEF BLADES ARE AMCA CERTIFIED • HOOD FIELD MOUNTED ON DUCT • USES FILTER RACK & FILTERS WITH UNIT -Control Types -D2DH W7220 controller, actuator w/feedback, adjustable drybulb controls -D2EH W7220 controller, actuator w/feedback, enthalpy controls -D2XH W7220 controller, actuator w/feedback, dual adjustable drybulb controls -D2ZH W7220 controller, actuator w/feedback, dual enthalpy controls -DODB-4 RTU Open - Premier Link - System VU, No controller, Adjustable dry bulb, Belimo actuator -DODB-X Comfordink - No controller, Adjustable dry bulb, Belimo MIT actuator with 500 ohm resistor -DOOH-H Communicating Honeywell actuator only -DOOH Non -communicating Honeywell actuator only -DOOB Belimo actuator with feedback and end switch NOTE: 10.243 R/A W i W"xH"xD" 21.294" x 22.000" x 16.346" 12.998 O/A PART NUMBER: ECH-SRTI2CA-Dxxx ILTER ACCESS DOOR "FILLER PANELS SHIPPED WITH ECONOMIZER" — IE� FTl4ti+ir�a` Imaw.noNK. Leo, MicraMfll ClorporMIon certifies that the models 4R1 anp N$1 Sno'wn hiI art• licensed to bear the AMCA $eal- The rahngs shown erg teased ern tests and procedures performed In Accordance with AMCA Publication S11 arrd cumnply wlth wqulremeMts of the AMCA Certified Ratings Programs. The AMCA Certified Ratings $esl applies to Air Leakage and Air Perlarmanee rst1n0s- I 17.023 I �unnT) �! Approved by: Date: Openings and dimensions may vary from contract. An order constitutes acceptance of these variances THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MANUFACTUER RESERVES THE RIGHT TO DISCONTINUE, OR CHANGE AT ANYTIME, SPECIFICATIONS & DESIGNS WITHOUT ANY NOTICE AND WITHOUT INCURING OBLIGATIONS. COPYRIGHT MICROMETL CORPORATION 2017. ALL RIGHTS RESERVED MICROMETL CORP * 3035 N. SHADELAND AVE., STE 300 * INDIANAPOLIS, IN 46226 * 1-800-662-4822 *** MICROMETL * 905 SOUTHERN WAY * SPARKS, NV * 1-800-884-4662 *** MICROMETL * 201 KODAK BLVD * LONGVIEW, TX 75602 * 1-903-248-4800 SUBMITTAL DATE: 4/19 SUBMITTED TO: Carrier COMPANY: MicroMetl DRAWN BY: ABC JOB NAME: WEIGHT: 90 lbs. NOTES: Page 2 of 2 Economizer - Ultra Low Leak, dedicated horizontal, W7220 controller or actuator only, single or two speed units, adjustable dry bulb, enthalpy, dual dry bulb, or dual enthalpy, painted O/A hood with aluminum filter, Barometric relief hood, All necessary panels and hardware included PART NUMBER: ECH-SRTI2CA-Dxxx Compliant Economizer: 1. Title 24: Economizers meet California Energy Commission Title 24-2013 / 2016 prescriptive section 140.4 (damper leakage etc.), and mandatory section 120.2.i for Fault Detection and Diagnostic controls. 2. ASHRAE 90.1: Economizers meet ASHRAE 90.1-2013 / 2016 damper leakage requirements as stated in Table 6.4.3.4.3., and meet 2016 Fault Detection and Diagnosis requirements in section 6.4.3.12. 3. IECC: Economizers meet IECC 2012 section C402.4.5.2 and, IECC 2015 sections C403.2.4.3 and C403.3.3.5 for outside air, return air, and relief damper (when provided) leakage requirements, and IECC 2015 section c403.2.4.7 for Fault Detection and Diagnostic requirements, Note: IECC 2015 section C403.2.4.7.1 requires differential return air sensor, which is included in some models (i.e. -DYXB) and must be ordered separately on others (i.e. -DYDB,-DYEB). 4. AMCA: Outside air and return air (volume) dampers are AMCA Class 1A rated 1" w.g. Refer to MicroMetl NS1 catalog sheet on web site for details. Relief air dampers (when provided) are also AMCA rated. Refer to GR1 series catalog sheet on web site for details. Approximate static pressure drop through R/A damper in inches w.g. CFM 750 1 1400 1 1630 1 1850 1 2000 1 2400 Pressure Drop 0.03 1 0.12 1 0.17 1 0.23 1 0.27 1 0.38 NOTE: 'frt f W 04rT4X u�iuw wruranp■�. i�0, MIcr4M•il Corpora#Ion certlfles that the models OR1 Elnp F1$1 aM—n Ihmvlrl are licensed to bear the AMCA Seal - The rahngs shown err haled an tests and proceQures performed In acemdance vrirh AMCA PUhllcahpn $11 aM c*mply with requlremems of the AMCA Certified Ratings Programs. The AMCA Certified Ratings $ealapprlen to Air Lemkege chid Air PerlonnanCe ratings_ Approved by: Date: Openings and dimensions may vary from contract. An order constitutes acceptance of these variances THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MANUFACTUER RESERVES THE RIGHT TO DISCONTINUE, OR CHANGE AT ANYTIME, SPECIFICATIONS & DESIGNS WITHOUT ANY NOTICE AND WITHOUT INCURING OBLIGATIONS. COPYRIGHT MICROMETL CORPORATION 2017. ALL RIGHTS RESERVED MICROMETL CORP * 3035 N. SHADELAND AVE., STE 300 * INDIANAPOLIS, IN 46226 * 1-800-662-4822 *** MICROMETL * 905 SOUTHERN WAY * SPARKS, NV * 1-800-884-4662 *** MICROMETL * 201 KODAK BLVD * LONGVIEW, TX 75602 * 1-903-248-4800 CURB ASSEMBL STEEL ATTACHMENT 1/2" 0 A307 BOLTS OR EQUIVALENT EQUALLY SPACED ON CURB BASE FLANGE ATTACHED TO L5X5X5/16" BELOW DECK AT EACH CONNECTION POINT AL DECK STRUCURAL STEEL SUPPORT BY OTHERS NUMBER OF ANCHORAGE BOLTS REQUIRED 1 FT FROM EACH CORNER AN EVENLY SPACED LONGSIDE SHORTSIDE 6 2 WOOD ATTACHMENT CURB ASSEMBL 31 E 1/4" SDS WOOD SCREWS OR EQUIVALENT EQUALLY SPACED ON CURB BASE FLANGE NUMBER OF ANCHORAGE BOLTS REQUIRED 1 FT FROM EACH CORNER AN EVENLY SPACED LONG SIDE SHORTSIDE 10 8 *ROOF CONCRETE SLAB I CONCRETE ATTACHMENT —CURB ASSEMBLY 5/8"0 X 3 1/2" SIMPSON STRONG BOLT 2 EQUALLY SPACED ON CURB BASE FLANGE. SPECIAL INSPECTION REQUIRED (ESR REPORT 3037) *CONCRETE SLAB: f'c = 4000 psi MINIMUM NORMAL WEIGHT CONCRETE 6" MINIMUM THICKNESS, 12" MINIMUM EDGE DISTANCE EMBED PER STAMPED *CONCRETE OVER METAL DECK: CALCULATION USE STEEL ATTACHMENT CONNECTION TO STEEL FRAMING BELOW DECK NUMBER OF ANCHORAGE BOLTS REQUIRED 1 FT FROM EACH CORNER AN EVENLY SPACED LONGSIDE SHORTSIDE 4 4 THIS DRAWING 8 THE INFORMATION CONTAINED APPROVALS DATE THEREIN IS THE CONFIDENTIAL, PROPRIETARY rtENLE xnmE: INFORMATION OF CRYSTAL DISTRIBUTION INC., '"* SPICk2f 2/23/201$ B MAY NOT BE USED OR REPRODUCED ECKE CURB -ATTACHMENTS WITHOUT THE APPROVAL OF CRYSTAL DISTRIBUTION, INC. ALL RIGHTS RESERVED ... ...� .,. __. T • ►� Contact us.c x ■ : CDI WWW.cdicurbs.cc or �E-F • �..,...n.• 1-888-234-7001 APPROXIMATE Cap CURB WEIGHT ILBSJ R�' 1:25 1 HE- 6 F 6 DUCT FLEX CONNECTIONS PROVIDED BY OTHERS INSULATED PANELS WHERE REQUIRED 2X4 WOOD NAILER SPRING ACCESS DOORS ARE GASKETED AND SCREWED ON GASKET MATERIAL PROVIDED FOR THE TOP PERIMETER (INCLUDING BRACES) SPRING PACKS MAY REQUIRE FIELD ADJUSTMENT (BY OTHERS) FULLY WELDED GALVANIZED (G-90) CONSTRUCTION WEATHER SEAL BETWEEN UPPER & LOWER SECTIONS PROVIDED(BULB SEAL) ANCHORING CURB TO ROOF FOR STEEL, CONCRETE OR WOOD, SEE DETAIL DRAWING "CURB ATTACHMENTS" 22 1 /8" 25 1 /8" 15 3/4" DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 FROM DRAWING OVERALL HEIGHT 23-1/4" 26-1/4" 30-1/4" 36-1/4" BASE CURB HEIGHT 11 14 18 24 BASE MATERIAL GA 12 12 12 12 CURB WEIGHT (LBS) 400 425 458 508 INSULATED COVER J a a D RETURN h� 33 15/16" 2" 70 7/8" 67 3/8" BASE CURB I.D. BASE CURB + 12 1/4 (36" MAX WITH PITCH) RETURN CURB BASE 14GA BASE SUF AT EACH LO UNIT BASE RAIL (8) #14 TEK SCREWS PER LONG SIDE THRU UNIT BASE RAIL AND CURB REVISIONS REV ECO# DESCRIPTION DATE APPROVED 1 INITIAL DRAWING 9/17/15 EH 2 UPDATED CBC & IBC 3/26/18 SRP AE _ATED COVER 40 9/16" 37 1/16" BASE CURB I.D. DETAIL G I ' SCALE 1 : 4 BASE CURB HEIGHT CURB DESIGNED TO MEET SEISMIC & WIND LOAD REQUIREMENTS FOR 2012 & 2015 IBC/ASCE 7-10, AND 2014 FLORIDA BUILDING CODE, 2016 CBC WIND DESIGN: MAX BUILDING HEIGHT 60FT, Kzt FACTOR = 1.00 MAX 2015 IBC/ASCE 7-10: MAX 185 MPH ULTIMATE DESIGN WIND SPEED, RISK CATEGORY II, III, OR IV BUILDING, EXPOSURE C SEISMIC: Ss = 2.00 MAX, IMPORTANCE FACTOR Ip = 1.5, SDS = 1.33 SEISMIC ISOLATION CURB 3 D ASSEMBLY M B LY THIS DRAWING & THE INFORMATION CONTAINED THEREIN IS THE CONFIDENTIAL, PROPRIETARY INFORMATION& AY NOT OF CRYSTAL USED REPRODUCED INC., WITHOUT THE APPROVAL OF CRYSTAL DISTRIBUTION, INC. ALL RIGHTS RESERVED CURB WEIGHT (LBS.) APPROVALS DATE TITLE: C7—DOXX-4000 349.58 DRAWN: spickar CHECKED: UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE: xco.os .XXXo.D3 �oo] xxx.o.o, 'S .012 vz• Thursday, June 08 2017 6:38:55 PM CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. 17560 TYLER ST NW �T71 T ELK RIVER, MN 55330 Ll 763 391-7790 ( ) (763)391-7851 FILENAME: C7-OOXX-4000 DRAWING NO.: REV: ASFOL O DIMENSIONS ARE AS FOLLOWS jzs40..] 3ROANGLE PROJECTION Econ: SCALE: 1 :18 SHEET: 1 OF 9 S:\CURBS CURB ADAPTERS\CX-XXXX-XXXX CONFORMING\C7-XXXX-XXXX ISO CURBS RAILS\C7-XXXX-4XXX CARRIER\4000\ ,,, VAK Co. slruclio : Engineering Services, LI.0 8285 SW Nimbus Avenue, Suite 104 Beaverton, Oregon 97008 503.718.5999 tel 503.718.5980 fax .Ji, / saardnerCaD-vakenaineerina.com M E M 0 TO: Steve Pickar, CDI Curbs Job # 17-001 BK FROM: Sam Gardner E.I.T., VAK Engineering PROJECT: Stock Carrier Iso Curb 4000 DATE: 11/12/2019 RE: Curb and Fastening Design As requested we have reviewed the fastener design for the unit to curb attachment and curb attachment to roof to support seismic and wind design loads which may be applied to the units it is supporting. From the supplied design criteria, we used a spectral response acceleration of 1.33g. Modification and system over -strength factors of 6.0 and 2.5 respectively were used. A wind speed of 185 mph. was used, with exposure C and risk category I, II, III, and IV. The mean roof height of the building was 60'. An analysis was performed on the rooftop unit provided. For the rooftop unit the weight provided ranged between 450b. and 1100lbs.. The roof itself was not included in this analysis. Based on the wind and seismic analyses we determined the governing load conditions for vertical loading and shear. Here are our findings from the analysis of the curb supporting the rooftop unit. Reactions Sunimar-� Per Side of Curb Long Side (x) (lb) Short Side (y) (Ib) Unit to Curb Connection Maximum Tension 1538 370 Maximum Compression 2159 1152 Maximum Shear 865 1383 Curb to Surface Connection Maximum Tension 5516 1733 Maximum Compression 6499 2742 Maximum Shear 1522 2524 Therefore, based on the design criteria provided, we have applied both wind and seismic reactions to the unit and curb to determine the fastening requirements. During our analysis, we determined that (8) #14 TEK screws will be required per each long side of the curb into both unit and curb for a total of (16). We checked the adequacy of the connection of the curbs to the structure, and the curb itself. The top of the curb was also checked in flexure and shear, and was found to be adequate. Isolators were assumed to be the JQA models, which were adequate, and the spring supports were also checked in compression and found to be adequate. Filename: 17 001BK LTRO1 11 12 2019 Page 1 of VAK ME1ld® 1111212019 Connection of the curb to the roof requires fasteners on both sides of the curb. Without knowing which fasteners to be used, 0.5" 0 A307 Bolts into steel, '/4" SDS Wood Screws into wood, and 5/8" Simpson Strong Bolts with 3.5" effective embedment into concrete were checked. From our analysis, we recommend either (8) 0.5" 0 A307 Bolts with (2) per short side, (10) 1/4" SDS Wood Screws with a 3.5" embedment with (8) per short side, or (4) 5/8" Simpson Strong Bolts with 3.5" of effective embedment per side of curb. If concrete is used, at least 6" of depth is necessary. For each fastener, install per manufacturer specifications and located 5/8" away from the curb wall. Please feel free to contact us should anything further be required or if questions arise. Best Regards, Sam Gardner, E.I.T. ``�', sNM�ES y . do mad: i * •_ w "/, Filename: 17 OO1BK LTRO1 11 12 2019 Page 2 of CDI'S "ISO CURB" INCORPORATES THE LATEST IN DESIGN AND INNOVATION for the HVAC market utilizing adjustable isolators in a single piece curb system. CDI Curb systems may be fully installed and roofed in prior to mounting RTU/AHU minimizing unaccounted labor time and delays with other "field assembly required" curbs on the market. Prime G-90 18ga weather skirting and bulb style weather seal provide a long lasting solution to the cracking and failing of "other" exposed rubber weather seal designs. All curb systems are subjected to SoliclWorks Simulation load testing prior to fabrication accommodating RTU/AHU and all accessories weight and center of gravity insuring a minimum 90% isolation efficiency. ONE PIECE CONSTRUCTION / same great CDI lead times apply AVAILABLE IN BOTH PLENUM (flex duct provided by CDI) AND DUCT DROP APPLICATIONS (flex duct provided by others) 18GA WEATHER SKIRTING 12/14GA STRUCTURAL C-CHANNEL FRAME RAIL 2" ISOLATOR REMOVABLE ACCESS DOORS FOR SPRING ADJUSTMENTS BULB STYLE WEATHER SEAL BASE CURB CONSTRUCTED OF 18,16,14, OR 12GA GALVANIZED STEEL FLEX DUCT (PLENUM APPLICATIONS) 2X4 WOOD NAILER FULLY INSULATED EXTERNAL SPRING SUPPORT LOCATED UNDER EACH ISOLATOR HEIGHT APPLICATION SPECIFIC STANDARD CONSTRUCTION DETAILS 1. Minimum overall height 18" 2. 2" Spring deflection 3. 2x4 wood nailer provided 4. 18-12ga Prime G-90 galvanized steel 5. Fully welded and mitered seams and corners 6. Weather skirt and bulb seal insure water tight seal 7. 2" minimum base flange for securing to building 8. Acoustically non-conductive materials minimize sound transitions 9. Stabilizing Isolators eliminate excess movement 10. Removable Access doors for spring isolator field adjustment 11. Same great CDI lead times apply 0 ISOLATOR SPEC 1. Housings Hot Dip Galvanized (HDG) 2. Hardware Zinc Plate 3. Springs Powder Coated or Zinc Plated 4. 2" Deflection 5. Style K Load Transfer Nut is pinned to stud 6. Large diameter springs with O.D. not less than 80% of rated deflection height 7. For compact support of heavy loads, some include inner springs 8. California Pre -Approved seismic protection OPA-0070 CURB SPECIFICATIONS Vibration Isolation curb systems are manufactured of 12-18ga (ASTM A653/653M) prime G90 galvanized steel construction. All corners and seams are mitered and fully welded with internal 12ga/A.I. structural cross and vertical supports when necessary. All curb systems are water tight and plenum applications are air tight utilizing internal flex duct. Top of all Vibration isolation curb systems are level with pitches built into curb when deck slopes. Vibration isolation curb systems are designed to provide a minimum of 90% isolation efficiency with 2" deflection. ALL CURB SYSTEM OPTIONS 1.External vestibules 2.Internal pipe chases 3.Sloped condenser pans 4.Horizontal discharge 5.Double wall 6.Perforated lining 7.Acoustical floor packages 8.HEPA Filter racks 9.Pitched Base Curb 10.Multi section curbs Iso curb with HEPA filter r;:F_�� ��- :� Proudly Made in America cdicurbs.com Performance Summary For 5t Unit 'roject: GRE Edmonds 99 01/27/202 'repared By: 12:54PI Part Number:48FCDA06A2A5-OAOAO ARISEER: ................................................................................................................................................... 14.00 Base Unit Dimensions UnitLength: ............................................................................................................................................. 74.4 in UnitWidth: .............................................................................................................................................. 46.6 in UnitHeight: ............................................................................................................................................. 33.4 in Operating Weight BaseUnit Weight: .................................................................................................................................... 556 lb Accessories LOW LEAK - Horizontal EconoMi$er X with solid-state W7220 controller: ............................................. 70 lb TotalOperating Weight: ........................................................................................................................... 626 lb Unit Unit Voltage -Phase -Hertz: ............................................................................................................... 208-3-60 AirDischarge: ................................................................................................................................ Horizontal FanDrive Type: .................................................................................................................................... Direct ActualAirflow: ........................................................................................................................................ 2000 CFM SiteAltitude: ................................................................................................................................................. 0 ft Cooling Performance CondenserEntering Air DB:.................................................................................................................... 95.0 F EvaporatorEntering Air DB:.................................................................................................................... 80.0 F Evaporator Entering Air WB:................................................................................................................... 67.0 F Entering Air Enthalpy:........................................................................................................................... 31.44 BTU/Ib EvaporatorLeaving Air DB:..................................................................................................................... 59.3 F EvaporatorLeaving Air WB:.................................................................................................................... 57.7 F Evaporator Leaving Air Enthalpy:.......................................................................................................... 24.85 BTU/Ib GrossCooling Capacity: ....................................................................................................................... 59.31 MBH GrossSensible Capacity: ...................................................................................................................... 44.73 MBH Compressor Power Input: ....................................................................................................................... 4.14 kW CoilBypass Factor: ............................................................................................................................... 0.163 Heating Performance HeatingAirflow: ...................................................................................................................................... 2000 CFM EnteringAir Temp: .................................................................................................................................. 70.0 F LeavingAir Temp: ................................................................................................................................... 95.0 F Gas Heating Input Capacity: ................................................................................................................... 67.0 MBH Gas Heating Output Capacity: ................................................................................................................ 54.0 MBH TemperatureRise: .................................................................................................................................. 25.0 F ThermalEfficiency(%):........................................................................................................................... 81.0 Supply Fan External Static Pressure: ......................................................................................................................... 0.50 in wg Options / Accessories Static Pressure Economizer: ...................................................................................................................................... 0.12 in wg Total Application Static (ESP + Unit Opts/Acc.):..................................................................................... 0.62 in wg FanRPM: ............................................................................................................................................... 2071 FanPower: .............................................................................................................................................. 0.95 BHP NOTE: ............................................................................................ Selected IFM RPM Range: 1420 - 2390 Electrical Data VoltageRange: ............................................................................................................................... 187- 253 Compressor#1 RLA:..................................................................................................................................16 Compressor#1 LRA:................................................................................................................................ 110 IndoorFan Motor Type: .......................................................................................................................... MED IndoorFan Motor FLA:..............................................................................................................................8.6 CombustionFan Motor FLA(ea): ............................................................................................................ 0.48 Packaged Rooftop Builder 1.55 Page 8 of 12 Performance Summary For 5t Unit 'roject: GRE Edmonds 99 01/27/202 'repared By: 12:54PI PowerSupply MCA: ................................................................................................................................... 31 Power Supply MOCP (Fuse or HACR):...................................................................................................... 45 DisconnectSize FLA:................................................................................................................................. 30 DisconnectSize LRA:..............................................................................................................................126 ElectricalConvenience Outlet: .............................................................................................................. None Outdoor Fan [Qty / FLA(ea)]: .............................................................................................................. 1/ 1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 92.1 89.3 85.6 125 Hz 83.4 79.3 84.7 250 Hz 77.4 71.9 80.5 500 Hz 73.9 66.0 76.0 1000 Hz 70.7 68.2 72.4 2000 Hz 68.1 59.5 68.0 4000 Hz 64.2 52.8 62.8 8000 Hz 60.2 47.0 59.3 A -Weighted 77.2 72.1 79.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: .................................. 30.0 ft 2. Horizontal distance from unit to receiver: ........... 50.0 ft 3. Receiver height above ground: ............................ 5.7 ft 4. Height of obstruction: ........................................... 0.0 ft 5. Horizontal distance from obstruction to receiver:.0.0 ft 6. Horizontal distance from unit to obstruction: ........ 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 L D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 L A Legend A Sound Power Levels at Unit's Acoustic Center, Lw Packaged Rooftop Builder 1.55 Page 9 of 12 Performance Summary For 5t Unit Project: GRE Edmonds 99 01/27/202 Prepared By: 12:54P B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2500 2.7 2.4 2300 2.1 2100 r: 1.8 � 9001 U) 1.5 Cn N d 17001 c� 1.2 1500 F 0.9 1300 F BHP 1.00 02 0.4 0.6 0_8 1.0 12 14 1.6 18 2.0 22 24 Airflow (CFM - thousands) RPM = 2071 BHP = 0.95 Maximum RPM = 2836 Maximum BHP = 5.00 SC - System Curve RP - Rated Point Packaged Rooftop Builder 1.55 Page 10 of 12 Unit Feature Sheet for 5t Unit Project: GRE Edmonds 99 01/27/2021 Prepared By: 12:54PN/ a rrier PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS - 14 SEER 3, 4, 5 TONS, 15 IEER 6 Ton ASHRAE to Puron. COMPLIANT" WEATHERMAKER SERIES 48FC units are single packaged gas heating, electric cooling units that are pre -wired and charged with Puron (R410) refrigerant. The units are factory tested in both heating and cooling modes. 3-5 ton models use single stage cooling capacity control. 6 ton model uses two stage cooling capacity control. STANDARD FEATURES INCLUDE: Puron (R-410A) HFC refrigerant Meets or exceeds ASHRAE 90.1 energy efficiency levels Scroll compressors with internal line break and overload protection • Single -stage cooling capacity 04-06 models, Two Stage on 07 models SEER's to 14.0, IEER's to 15.0 Acutrol • refrigerant metering system on 04-06 models, TXV on 07 size models Exclusive non -corrosive composite condensate pan in accordance with ASHRAE Standard 62, sloping design, side or center drain Standard cooling operation up to 115°F (46°C) and down to 40oF (4°C) - down to 25' F (-4' C) with winter start kit. Pre -painted exterior panels and primer -coated interior panels tested to 500 hours salt spray protection Fully insulated cabinet NEW Direct Drive - EcoBlue• Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor ' New Unit Control Board with intuitive quick fan speed adjustment Exclusive IGC solid-state control for on -board diagnostics with LED error code designation burner control logic Induced draft gas heat combustion design Redundant gas valves with up to two stages of heating Low pressure and high pressure switch protected. MAINTENANCE FEATURES: Access panels with easy grip handles Innovative easy starting, no -strip screws on unit access panels Two-inch disposable return air filters and Tool -less filter access door New unit control board to facilitate simple safety circuit troubleshooting and simplified control box arrangement INSTALLATION FEATURES: Thru-the-bottom power entry capability Single point gas and electric connections Full perimeter base rail with built-in rigging adapters and fork slots Field convertible from vertical to horizontal airflow STANDARD WARRANTY: 10-year heat exchanger - 15-year stainless steel option 5-year compressor Approved and certified by: 3-tear SystemVu- 1-year parts Many optional upgrades also available ' OPTIONS INCLUDE BUT ARE NOT LIMITED TO: Use of the AHRI Certifietl C TM Mark indicates a • Intelligent SystemVu communicating controls U S manufacturer's • RTU Open Multi -Protocol DDC Controls Participation in the program For verification • Supply and Return Air Smoke Detectors, high static motors of certification for individual • Louvered condenser coil guards prr ucts, go to .ahridireotory.org. • Disconnect switch and convenience outlet options • Stainless Steel heat exchanger option • Corrosion resistant coil coating. • MERV-8 Return Air Filters • Patented Humidi-MiZer ® adaptive dehumidification system. • Hinged access panels • Integrated economizer system. Low and Ultra Low Leak versions • Phase Monitor Protection • Condensate Overflow Protection For a complete list of options and accessories refer to the Product Data Catalog for this unit. Packaged Rooftop Builder 1.55 Page 11 of 12