Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2021-0070+Fire_Sprinkler_Equipment_Specification_Sheets+7.9.2021_2.08.53_PM+2292792
RECEIVED FIR2021-0070 Jul 12 2021 SMITH FIRE SYSTEMS, INC. CITY OF EDMONDS DEVELOPMENTSERIIgE06 54th Avenue East • Tacoma, Washington 98424 DEPARTMENT (253) 926-1880 FAX (253) 926-2350 REVIEWED CONTR. REG. NO. SMITHFS1360T HWY 99 EDMONDS APTS NC20001 3326 HIGHWAY 99 EDMONDS, WA 98026 EQUIPMENT INDEX NO. MANUFACTURER SIZE MODEL DESCRIPTION 1 VICTAULIC 2.5" 705 BUTTERFLY CONTROL VALVE W/ TAMPER SWITCH 2 POTTER 2.5", VSR WATER FLOW SWITCH 6" 3 AGF 2" 1011T TEST AND DRAIN 4 ASHCROFT 1/4" 1005P WATER PRESSURE GAUGE 5 RELIABLE 4" EX -LP DRY PIPE VALVE ASSEMBLY 6 POTTER 1/2" PS10-2A ALARM PRESSURE SWITCH 7 POTTER 1/2" PS40-2A SUPERVISORY AIR PRESSURE SWITCH 8 RELIABLE 1/2" A-2 AIR MAINTENANCE DEVICE 9 JENNY 1215 G2S-17UMS AIR COMPRESSOR GAL. 10 AGF 2" 8451A RISER ASSEMBLY W/ PRESSURE RELIEF 11 GLOBE 2" RCV CHECK VALVE 12 WILSON 2.5" IE23 GROOVED ANGLE HOSE VALVE 13 RELIABLE 4.9K F1 RES49 RES. SPRINKLER 14 RELIABLE 5.6K F1 FR56 SPRINKLER 15 RELIABLE 5.6K F156 SPRINKLER Firel-ock° Butterfly Valve ✓ctaullc` Series 705 with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION • Available Sizes: 2 — 12"/50 — 300 mm • cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa 120 bar. • Designed for fire protection services only. • Features a weatherproof actuator housing Approved for indoor and outdoor use. • Actuation options: Hand wheel (2 — 12"/50 — 300 mm) • Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c L us FM VdS FL -PCB] 0" LISTED G410001 104j/04 NOTES • Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. 1 �ctauliiic® virtaidir rnm 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2 50 up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 21/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4 100 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6 150 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS — MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 — 6'750 — 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 — 12'7200 — 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: ❑ 2 — 8750 — 200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing ❑ 10 — 127250 — 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. virtaidir_rnm 2 ✓ctaulic® victaulic.com 4.0 DIMENSIONS Series 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 _ _ 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 _ _ 101.6 107.2 114.3 45.0 76.1 mm 3.000 3.77 2.28 7.54 _ _ 4.00 4.22 4.50 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 _ _ 114.3 107.2 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 _ _ 5.50 4.22 4.50 2.20 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 _ _ 139.7 107.2 114.3 55.9 133 mm 5.250 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 139.7 mm 5.500 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 _ _ 166.6 157.2 160.0 65.5 159 mm 6.250 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 165.1 mm 6.500 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 2.58 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 _ 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 _ 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 _ NOTE • Optional V2715 mm tap available. Contact Victaulic ford eta I Is. 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com ✓ctaulic® victaulic.com 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter m m mm Feet/m inches inches of pipe 2 2.375 6 50 60.3 1.8 21/2 2.875 6 65 73.0 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 8 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev H Updated 03/2017 0 2017 Victaulic Company. All rights reserved. victaulic.com il ✓ctaulic® victaulic.com 5.1 PERFORMANCE Series 705 Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, values Formulas for K, values AP = Q2 Where: AP = Qz C 22 Q = Flow (GPM) K zZ AP = Pressure Drop (psi) Q = Cv x AP C = Flow Coefficient Q — K x AP Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches Cv mm mm 2 2.375 170 50 60.3 260 21/2 2.875 65 73.0 76.1 mm 3.000 260 76.1 3 3.500 440 80 88.9 4 4.500 820 100 114.3 108mm 108mm 820 5 5.563 1200 125 141.3 133 mm 133 mm 1200 139.7mm 5.500 1200 139.7 6 6.625 1800 150 168.3 159 mm 159 mm 1800 165.1 mm 6.500 1800 165.1 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 12.750 9000 300 323.9 Where: Q = Flow W/hr) AP = Pressure Drop (Bar) KV = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches K mm mm 2 2.375 147 50 60.3 21/2 2.875 225 65 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108mm 108mm 710 5 5.563 1040 125 141.3 133 mm 133 mm 1040 139.7mm 5.500 1040 139.7 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6.500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 300 323.9 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaulic® vir+nrldir rnm 6.0 NOTIFICATIONS A WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring 1. The supervisory switch contains two single pole, double throw, pre -wired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the "OPEN" position. 5. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 6. A #14 insulated ground lead (green) is provided. Switch #1 = S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Sl Normally Closed: (2) Blue Common: (2) Yellow S2 fNormally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe UL LISTED JUNCTIONN BOX CONDOR\ i i ''/z" NPT CONDOR CONNECTORS WIRE NUTS FIRE ALARM TO END -OF -LINE RESISTOR, CONTROL PANEL OR NEXT INDICATOR SUPERVISORY CIRCUIT SWITCH CONTACT RATING:IDA JR AT 125 AND 250VAC, O.SA AT 125 VDC,0.25 AT 250 VDCBELL OR VOLTAGE SOURCE HORN Switch 1: 2 leads pertermina Switch 2:1 lead per terminal NOTES • The above diagram shows a connection between the common terminal (yellow — S1 and yellow -with -orange stripe — S2) and the normally closed terminal (blue — S1 and blue -with -orange stripe — S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). • Only S1 (two leads per terminal) may be connected to the fire alarm control panel. • The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. vir+mrdir rnm 0 ✓ctauli victaulic.com 7.1 REFERENCE MATERIALS 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty 1-100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com ✓ctaulic® CrPOTTER The Symbol of Protection Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 21/2" DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" VSR-3 1/2 1144435 4" DN100 VSR-4 1144404 5" VSR-5 1144405 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdSApproved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) -UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL • Non -corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. CAUTION Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40, sizes 2" thm 8" (50 mm thm 200 mm). LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV M PAGE 1 OF 4 11115 (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non -corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. Fig. 1 Retard Adjustment DO NOT LEAVE COVER OFF FOR aNEXTENDED PER7oDOFTIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms DIRECTION OF WATERFLOW TIGHTEN NUTS ALTERNATELY O MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION l \ OF WATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect I -E��- _E7�_ ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing water activates device in one direction only) DWG t146-1t 50- ADAPTER ADAPTER 20-+2= MAX. DN50 ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DWG# 1146-IF Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Lightwall Schedule 10 (iIL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch min inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 +.125/- 062 33.0 2.0 VSR-21/2 2.5 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - VSR-21/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00±.125 50.8t2.0 20 27 VSR-31/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 - - 0.148 1 3.76 1 0.322 8.18 0.248 1 6.3 1 0.177 1 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146 - REV M PAGE 2 OF 4 11115 CF�)POTTER The Symbol of Protection Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Fig. 5 Typical Electrical Connections Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). rasa VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal � % I�CO�Ilj6 1 �0�6 �� DWG. #1146-16 AWATNING M An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. NEUTRAL FROM BREAKER NEUTRAL FROM BELL 1 BREAKER J LINE FROM BREAKER EOL (End Of Line Resistor) NOTE: When connecting to a UL Listed control panel, use the panel's resistor value for circuit supervision. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 6 Mounting Dimensions 5.56 in Fig. 7 3.50 in (141.2 mtn) 2.00 in r (89.0 —)y (50.8 mm) GREEN GROUND SCREWS 2.34 in (59.4 —) PI E DIA. U-BOLT NUT + 5.25 in U-BOLT WASHER (+ 33.4 —) PIPE SADDLE 4 � 1 PIPE t t PLASTIC PADDLE---'® Q DWG. 11d8-id U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50 — DN 65 2-2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80 — DN 200 3-8 in OWG 1146-15 PRINTED IN USA MFG. #5401146 - REV M PAGE 3 OF 4 11115 (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field -replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re -install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 8 DO NOT REMO'V (2) RETARD HOL SCREWS Removal of Waterflow Switch REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY Li (2) LOCATING PINS/ n (2) LOCATR BOSSES IN DWG# 1146-10 • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV M PAGE 4 OF 4 11115 Model 1011T TESTANDRAIN'5 Sectional Floor Control Test and Drain Valve with Pressure Gauge for Systems Requiring Pressure Relief Valve Sizes: 3/4.. 1 1'�a'. 1 1/2 e�u The AGF Model 1011T TESTANDRAIN° provides the test and express drain functions for wet fire sprinkler systems on multi -story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model 1011A fea- tures a Model 7000 Pressure Relief Valve with drain pipe, 31/2" Model 7500 Pressure Gauge and 3-Way Globe Valve. The Model 1011T is available in a full range of sizes (3/4" to 2") with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UVFM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). • Complies with NFPA 13 Requirements • Compact, Single -Handle Ball Valve • Tamper -Resistant Test Orifice and Sight Glasses • 300 PSI rated. • Specifiable orifice sizes: %" (2.8K), 7/16" (4.2K), 1/2" (5.6K),'�/32" (8.0K), %" (11.2K, ELO), 3/4" (14.OK, ESFR), and K25 • Relieves Excess System Pressure caused by Surges or Temperature Changes • Includes Model 7500 Pressure Gauge and UVFM Model 7600 Globe Valve • Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing • Locking Kit Available Repair kits are available for all TESTANDRAIN° valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. SS-M1011T_V001 - 06/13 TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. Model 1011T LISTED11 TE TAN FM Model 1011T 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve, APPROVED Model 7500 Pressure Gauge, and Model 7600 1/411 3-Way Globe Valve Dimensions SIZE A B C D E F 3/ 101/4 33/8 113/16" 49/16 63/811 83/4" (256 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) (119 mm) 1 101/4" 33/8" 113/16" 49/16" 63/811 83/411 (256 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) (119 mm) 11/411 101/2" 35/8" 115/16" 59/16" 71/211 91, (263 mm) (91 mm) (51 mm) (141 mm) (192 mm) (225 mm) 1'Y2" 111/2" 37/8" 25/8" 81/4" 107/8" 911/16" (288 mm) (99 mm) (67 mm) (207 mm) (274 mm) (242 mm) 211 1 11/2" 37/8" 25/8" 81/4" 107/8" 911/16" (288 mm) (99 mm) (67 mm) (207 mm) (274 mm) (242 mm) The Model 1011T provides the following... From the 2013 Edition of NFPA 13 Chapter 8.16.2.4.1 * Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) — & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion -resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1 " in diameter, terminating in a smooth bore corrosion -resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1 ", at least one of which shall be brass. Chapter 7.1.2 - a wet pipe system shall be provided with a listed relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than 1/2" in size shall be provided on the discharge side of the pressure -reducing valve set to operate at a pressure not exceeding rated pressure of the system. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve Chapter 8.16.1.2.2 Pressure gauges shall be installed on the inlet and outlet sides of each pressure reducing valve. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 Job Name: Architect: Engineer: Model 1011T - Front View Orifice Sizes W 7116n 1/2° "/32% W ELO`, 3/a" ESFR`, and K25"' Materials Handle ................ Steel Stem ................... Rod Brass Ball ...................... C.P. Brass Body ................... Bronze Valve Seat........... Impregnated Teflon° Indicator Plate .... Steel Relief Valve......... Bronze Bypass Fittings... Brass Bypass Tubing.... Nylobraid Approvals UL and ULC Listed: (EX4019 & EX4533) FM Approved �1 NYC -BSA No. 720-87-SM MADE IN U.S.A. www.testandrain.com "Available on 11/4" to 2" size units only • "Available on 11/2" and 2" size units only Contractor: OASHCROFT 8 CONV Zv In ISO 9001 REGISTERED FIRM Type 1005P Commercial Gauge FEATURES • Corrosion resistant ABS case • Now available in 1%-- 3Y2—sizes in both lower and back connection. • New panel mount conversion kit allows user to transform a back connect gauge into a panel -mount gauge. The essence of Ashcroft Type 1005P gauges is attractive styling, a technically superior design, durable construction and economy. The core of the Type 1005P gauge is the patented PowerFlex'" movement. This movement has been thoroughly tested and proven to be more resistant to shock, vibra- tion, and pulsation than conventional movements, thus ensuring a more accurate, dependable, long-lasting gauge. True Zero" indication, a unique safety feature standard on these gauges, is the accurate indication of zero pressure being applied to the gauge. In addition to the increased safety benefits, this means reduced inspection and manufacturing costs for you and your customer. For added versatility the new panel mount conversion kit, ordered as an accessory, allows the user to convert the 1005P back connect gauge to a panel mount gauge. Gauge installation and replacement is easy with the panel mount conversion kit. Simply push the gauge in to install or push the gauge out to uninstall (not possible to uninstall 1 %" gauge). COMMONLY USED ON Compressors, filter regulators, fluid power equipment, medical equipment, pool and spa filters, automotive diagnostic equipment, beverage dispensing equipment, industrial machinery, a variety of other applications HOW TO ORDER (Typical example) PRODUCT SPECIFICATIONS Ashcroft Model No.: 1005P Sizes: 1 F,"" 2 "" 2F "" 3%" Case: Black, ABS Window: Polycarbonate Dial: Black figures on white back- ground, aluminum Pointer: Black, aluminum Bourdon Tube: C-shape bronze (2""-3X"" vacuum-600 psi and co,mpound; 1%, vacuum-1000 psi) Helical bronze (2"-3%"", 1000-6000 psi) Movement: PowerFle)C with polyester segment Socket: Brass Restrictor: .013-orfice throttle plug in gauges 1000 psi and above Accuracy: ASME B40.1, Grade B, ±3-2-3% Connections: % and X NPT, lower and back (1%"not available in X NPT back) Ranges:1Y2" Vac-1000 psi only 2- ' 2%" Vac-6000 psi and compound 3%" Vac-600 psi and compound Operating Temp.:-40OF to 1500F, —400C to 650C OPTIONAL FEATURES Case: Panel mount conversion kit (XUC), ordered as an accessory kit Case color (other than black) Vent hole Pointer: Adjustable Min/max assembly Movement: Flutterguard" Socket: Non-standard length or thread Throttle plugs — 0.007,"0.013," 0.020,"" 0.063,"Nickel plated, Teflon taped, Top or side connection Dials: Customized Non-standard ranges Receiver ranges — 0/100 linear 0/100 percent 0/10 sq. root Aluminum (for added corrosion resistance) Others: UL 404 and 252A listing for compessed gas service Bulk packaging 20 W 1005 P H 02L XAP 400# Dial Size: 2" Movement: Patented PowerFlex" Case Type Number: 1005P Case Material: ABS Socket Material: Brass Connection Size/Location: % NPT Lower Option: Adjustable Pointer Range: 0/400 psi All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408 © Ashcroft Inc. 2007 8/07 email: info@ashcroft.com • www.ashcroft.com BULLETIN CG-15P OASHCROFT Type 1005P Commercial Gauge GAUGE DIMENSIONS I- B� K - - C - W F1 SQ. NPT FLATS W i M F NPT H DIAL SIZE inches A C H K M EIGH N(eZs)T LOWER BACK LOWERS BACK LOWERW BACK BACK (MM) NPT NPT 1.66 1.64 1.07 1.01 1.60 Ye or 1.41 0.38 0.62 0.62 0.56 0.44 1.5 1%- (42) (42) (27) (26) (41) Y4 /e (36) (10) (16) (16) (14) (11) 2.11 2.11 1.07 1.05 2.05 '/8 or '/a or 1.85 0.38 0.85 0.82 0.56 0.56 2 2.6 (54) (54) (27) (27) (52) '/4 '/a (47) (10) (22) (21) (14) (14) ""7 2.74 2.74 1.12 1.14 2.67 Ye or Ya or 2.18 0.38 0.78 0.83 0.56 0.56 2 (70) (70) (28) (29) (68) 1/41/4(55) (10) (20) (21) (14) (14) 3.3 3.70 1.14 1.28 3.62 /e or 1/8or 2.72 0.47 0.72 0.92 0.56 0.56 r3.70 3fz"" (94) (94) (29) (32) (92) '/4 '/a (69) (12) (18) (23) (14) (14) 5.4 PANEL MOUNT SLEEVE DIMENSIONS (ordered as an accessory kit) E Jr B T H I 10-32 STUDS IFHOLE IN C I� PANEL J ' - II G WJ [�7 C OMER' PANE L D - ABS CASE PANEL MOUNT SLEEVE INCHES (MM) A B C D E IF H J Conn. NPT 2.06 1.05 1.76 1.87 0.13 .60 1.20 0.69 7/16 sq. 14" , (52) (27) (45) (47) (3) (15) (31) (18) (11) 2.52 1.05 2.23 1.91 0.17 .82 1.64 0.69 'A. sq. 2 or Y. (64) (27) (57) (48) (4) (21) (42) (18) (14) 3.18 1.15 2.87 1.99 0.16 1.13 2.26 0.69 '/+s sq. 2 �" or Y. (81) (29) (73) (51) (4) (29) (57) (18) (14) 4.10 1.24 3.80 2.15 0.20 1.61 3.21 0.69 '/+s sq. 3.5" or /a (104) (31) (96) (55) (5) (41) (82) (18) (14) PANEL CUT OUT INCHES (MM) Min. Max. 1.850 1.968 11A- (47) (50) 2.330 2.440 2"" (59) (62) 2.992 3.110 21A- (76) (79) 3.898 4.016 (99) (102) ISO 9001 REGISTERED FIRM All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408 BULLETIN CG-15P 0 Ashcroft Inc. 2007 8/07 email: info@ashcroft.com • www.asheroft.com Bulletin 358 Rev. C Model EX Low Pressure co C Reliable Features 1. Differential latching clapper -type, lightweight, dependable construc- tion. 2. Low Air Pressurized System, 8 psi -to- 28 psi (0.6 bar -to- 1.9 bar) Max 3. Reset externally. Cover removal is not required. 4. No priming water requirement 5. Hydrostatic testing with the clapper in the closed position 6. No riser check valve required 7. Valve latches in open position. No pressure -operated relief valve is required. 8. Nitrogen pressurized system optional 9. Drain valve to drain potential standing water column. 10. Grooved inlet and outlet. 11. Pressure rating of 250 psi (17.2 bar) or 300 psi (20.7 bar) [(4" (100mm), 6" (150mm) & 165mm only)]. Note: For retrofit applications where an existing pneumatic supply is available. The Reli- able Model EX Dry Valve can be oper- ated with 40 psi (2.8 bar) maximum air or nitrogen pressure. The higher pres- sure may result in a delay in valve op- eration and longer water delivery time when compared to the lower (design) pressures of the valve. Dry Pipe Valve System 2" (DN50)5 21/2" (DN65)5 3" (DN80), co 76 mm, 4" (DN100 ), 6" (DN150)9< 165 mm & 8" (DN200) Listings & Approvals (Only when used with Reliable's Trim Sets.) 1. Listed by Underwriters Laboratories, Inc. and UL certified for Canada (cULus). 2. Certified by Factory Mutual Approvals (FM). 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhutung GmbH (VdS) (DN50, DN65, DN80, DN100, DN150, and DN200 sizes only). 5. EN Certificates (CE) per EN 12259-3:2000 + A1:2001 + A2:2005 DN50: 0786-CPR-40300 DN65: 0786-CPR-40301 DN80: 0786-CPR-40302 DN 100: 0786-CPR-40303 DN 150: 0786-CPR-40304 DN200: 0786-CPR-40305 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 N SECTION VIEW OF MODEL EX DRY VALVE WITH CLAPPER IN "OPEN", "CLOSED" AND "LATCHED" POSITIONS SYSTEM SIDE SUPERVISORY GAS PORT PUSH ROD ACTUATOR SUPERVISORY GAS PORT ACTUATOR - DRAIN PORT PUSH ROD CHAMBER WATER PORT TO SYSTEM T LEVER CLAPPERIN "OPEN" POSITION CLAPPERIN "LATCHED" POSITION CLAPPERIN 'CLOSED' POSITION - ALARM PORT CONDENSATE DRAIN PORT - TEST PORT EXTER RESET KI SUPPLY SIDE WATER PORT SYSTEM DRAIN PORT FROM 359FG01B SUPPLY Fig. 1 REAR VIEW OF MODEL EX DRY VALVE PUSH INWARD AND ROTATE EXTERNAL RESET KNOB CLOCKWISE TO RESET CLAPPER. DO SO ONLY WHEN PUSH ROD CHAMBER IS UNPRESSURIZED (0 PSIG). IT ACTUATOR/PUSH ROD CHAMBER General The Reliable Model EX Low Pressure Dry Pipe Valve is a hydraulically operated, differential latching clapper -type valve (see Fig 1.) designed for use as a primary control valve in a dry pipe valve system. The trim set used with the Model EX Low Pressure Dry Pipe Valve allows the sys- tem's air or nitrogen pressure requirement to be consider- ably less than the available water supply pressure (See Table A, page 7). The following benefits are a direct result of the ability to use lower air pressure: 1. In refrigerated area systems, lower air pressure de- creases the possibility of ice plugs, which could im- pede or prevent the flow of water to sprinkler heads in the event of fire. 2. Lower air pressure (volume) will enable smaller ca- pacity, lower cost dehydration equipment when it is required. 3. Lower air or nitrogen pressure can reduce water de- livery time when the system actuates, and in some cases, may eliminate the need for an accelerator. 4. Low pressure requirements make the use of dry ni- trogen gas, instead of air, practical even on larger systems. Resulting benefits include a lower -than -air dew point, which minimizes ice plugging of system lines, and enhances "user friendliness" during in- stallation and operation. 5. System maintenance is simplified since priming water is not required and the Dry Pipe Valve can be reset externally without cover removal. This is ac- complished by pushing in and turning the external reset knob at the rear of the Dry Pipe Valve (see Fig.1). This feature provides a significant system - restoration time advantage. The Model EX Low Pressure Dry Pipe Valve's trim set (see Fig.2) provides all of the necessary equipment for connec- tions to the pushrod chamber's inlet and outlet ports, the 1'/4" (30mm) or 2" (50mm) main drain, alarm devices, air supply, water supply and required pressure gauges. This trim set is available in individual parts, in time -saving, seg- mentally assembled kit forms, or fully assembled to the Model EX Low Pressure Dry Pipe Valve (with or without a control valve). All the sizes of the Model EX Low Pressure Dry Pipe Valve trim sets may be equipped with the optional Reliable Model B1 Accelerator, trim kit P/N 6516000003, (see Figs. 2 & 3). This device acts as an exhauster which will hasten the operation of the Model EX Low Pressure Dry Valve and minimize the water delivery time for the entire system. System Operation The Reliable Model EX Low Pressure Dry Pipe Valve is shown in both closed and open positions in Fig. 1. In the closed position, the supply pressure acts on the underside of the clapper and also on the push rod through the push rod chamber's inlet restriction. The resultant force due to the supply pressure acting on the push rod is multiplied by the mechanical advantage of the lever and is more than sufficient to hold the clapper closed against normal sup- ply pressure surges. When a sprinkler operates, there will be a loss of air or nitrogen pressure in the sprinkler system's piping which will cause the Model EX Low Pressure Dry Valve to open. The loss of air pressure allows a releasing discharge of water from the pushrod chamber. Since the pressure can- not be replenished through the inlet restriction as rapidly as it is vented, the push rod chamber pressure falls in- stantaneously. When the push rod chamber pressure ap- proaches approximately one-third of the supply pressure, the upward force of the supply pressure acting beneath the clapper overcomes the lever -applied force thereby opening the clapper. Once the clapper has opened, the lever acts as a latch, preventing the clapper from returning to the closed po- sition. Water from the supply flows through the Dry Pipe Valve into the system piping. Water also flows through the Dry Pipe Valve's alarm outlet to the alarm devices. After system shutdown, resetting the Model EX Low Pressure Dry Pipe Valve is quite simple. Doing so only re- quires pushing in and turning the reset knob at the rear of the valve (see Fig. 1). The external reset feature of the Model EX Low Pressure Dry Pipe Valve provides a means for simple, economical system testing, which is one es- sential facet of a good maintenance program. The external reset feature does not, however, eliminate another impor- tant facet of good maintenance, namely, periodic cleaning and inspection of the internal valve parts. In the event that water builds up inside the valve due to condensate from the air supply system or water left inside from valve system testing, a drain is available for venting. After closing the main supply valve, a small valve over the drain cup can be opened slightly until the water inside the valve body and the main pipe column has drained. The Model B Manual Emergency Station is also included in the Model EX Low Pressure Dry Pipe Valve trim set. It consists of an aluminum nameplate mechanically at- tached to a ball valve. The valve handle in its OFF position is guarded against accidental turning to the ON position (and system discharge) by a nylon cable tie provided with each trim kit. The cable tie is inserted after the system has been restored for operation. The nylon cable tie is de- signed to allow, in case of an emergency, forceful turning of the valve handle to the ON position. As an alternative to the Model B Hydraulic Manual Emergency Station, the Model A Hydraulic Manual Emergency Pull Box (see Reli- able Bulletin 506) is also available and can be provided as an option. Whenever ambient temperature conditions are high, the water temperature in the Model EX Low Pressure Dry Pipe Valve's pushrod chamber could possibly increase, thereby increasing the pressure in the chamber to values exceed- ing the rated pressure of the system. In an indoor installa- tion where standard room temperatures are exceeded, a pressure relief kit may be needed. Pressure relief kit, P/N 6503050001, can be installed into the pushrod chamber's releasing line to limit the pressure to 250 psi (17.2 bar). 3. rl LOW AIR PRESSURE SWITCH (NOT INCLUDED WITH LOOSE AND SEGMENTALLY ASSEMBLED) FROM AIR OR / NITROGEN SUPPLY / PRESSURE RELIEF VALVE I ENTTO I ATMOSPHERE TO MODEL EX SYSTEMQ OPTIONAL PUSH -ROD CHAMBER DVALV E VALVE MODELBI PRESSURE GAUGE ACCELERATOR KIT (PART NUMBER 651600DOI3) I L/ PSI TO �CRIP UP TO DRIP CUP - re-sm f I I I t4,b I TO ALARM PRESSURE SWITCH DRAIN (NOT INCLUDED WITH LOOSE AND SEGMENTALLY ASSEMBLED) I I I / �TO MECHANICAL GPRINKLER ALARM I ' / J' / / TO NON-SHENCEABLE ALARM PRESSURE SWITCH (REF. NFPA 72) -_J u r WATER SUPPLY PRESSUEGAUGE THEM DEL EX DRY PIPE VALVE DOES NOT REQUIRE AN IN -LINE CHECK VALVE FOR AIR MAINTENANCE. THE RECOMMENDED INSTALLATION LOCATION FOR AFIRE DEPT. CONNECTION (FDC) IS BETWEEN THE MODEL EX DRY PIPE VALVE AND THE WATER SUPPLY CONTROL VALVE. WATER SUPPLY THE CONTROL(BUTTERFLY) VALVE, ADJOINING COUPLING CONTROL ARE INCLUDED IN THE "FULLY ASSEMBLED TO MODEL E% VALVE DRY PIPE VALVE WITH CONTROL VALVE" TRIM CONFIGURATIONONLY. REFER TO PAGE #90FTHIS BULLETIN FOR PART NUMBER/ORDERING INFORMATION. THE CONTROL (BUTTERFLY) VALVE, INLET SPOOL, AND ADJOINING COUPLINGS ARE INCLUDED IN THE'FULLY ASSEMBLED TO MODEL EX DRY PIPE VALVE WITH CONTROL VALVE WI INLET SPOOL" TRIM CONFIGURATION ONLY. REFER TO PAGE 99 OF THIS BULLETIN FOR PART NUMBERIORGERING INFORMATION, Fig. 2 1) INDIVIDUAL PARTS (MODEL EX DRY PIPE VALVE SOLD SEPARATELY( 2) SEGMENTALLY ASSEMBLED (MODEL EX DRY PIPE VALVE SOLD SEPARATELY) 3) FULLY ASSEMBLED TO MODEL EX DRY PIPE VALVE WITH CONTROL VALVE 4) FULLY ASSEMBLED TO MODEL EX DRY PIPE VALVE WITH CONTROL VALVE W/ INLET SPOOL 5) FULLY ASSEMBLED TO MODEL EX DRY PIPE VALVE WITHOUT CONTROL VALVE ALL STEEL COMPONENTS OF THE TRIM ASSEMBLIES ARE GALVANIZED Hydrostatic Testing of EX Valves and EX Systems As required by NFPA 13, fire sprinkler systems with working pressures up to and including 150 psi are to be hydrostatically tested at a water pressure of 200 psi and maintain that pressure without loss for two hours. Fire sprinkler systems with working pressures above 150 psi are required to be hydrostatically tested at 50 psi above the system working pressure and maintain that pressure without loss for two hours. In addition to the hydrostatic tests described above, dry pipe systems require an ad- ditional low pressure air test. In some cases, hydrostatic testing (in accordance with the NFPA 13 requirements noted above) will result in pres- sures that exceed the working Pressure of the valve and trim kit for the two-hour test period. The valve and appli- cable trim kit have been tested, approved and listed under these conditions and as such, hydrostatic testing in accor- dance with NFPA 13 is acceptable. In addition, the clap- per can remain in the closed position and the trim kit need not be isolated, as each has been designed to withstand hydrostatic testing as required by NFPA 13. Hydrostatically testing the valve and trim to pres- sures higher than their rating is limited to the hydrostatic test as referenced by NFPA13. It does not address the occurrence(s) of a "water hammer" effect, which can in- deed damage the valve. A "water hammer" in the water supply piping of the valve can create pressures in excess of the rated pressure and should be avoided by all neces- sary means. This condition may be created from improper fire pump settings, underground construction work, or an improper venting of trapped air in the water supply piping Technical Data Reliable Model EX Low Pressure Dry Pipe Valves, with associated trim, sizes 2" (50mm), 21/2" (65mm), 3" (80mm), 76mm & 8" (200mm) are rated for use at a minimum water supply pressure of 20 psi (1.4 bar) and a maximum water supply pressure of 250 psi (17.2 bar), sizes 4" (100mm), 6" (150mm) & 165mm are rated for use at a minimum wa- ter supply pressure of 20 psi (1.4 bar) and a maximum wa- ter supply pressure of 300 psi (20.7 bar). Water supplied to the inlet of the valve and to the pushrod chamber must be maintained between 40°F (4°C) and 140°F (60°C). The following list of technical bulletins pertains to valves and devices that may be used in this Dry Pipe Valve sys- tem: Model EX Dry Pipe Valve Reliable 358/359 Mechanical Sprinkler Alarm Reliable 612/613 Pressure Maintenance Device Reliable 254 Nitrogen Regulating Device Reliable 254 Model B1 Accelerator Trim Kit Reliable 323 Hydraulic Emergency Station (Model A) Reliable 506 Low Air Pressure Alarm Switch (Potter) 5401564 Waterflow Pressure Alarm Switch (Potter) 5400928 Model EX Low Pressure Dry Pipe Valve Description 1. Valve & System - Pressure Rated to 250 psi (17.2 bar) for 2" (50mm), 21/2"(65mm), 76mm and 8" (200mm) and 300 psi (20.7 bar) for 4" (100mm), 165mm & 6" (150mm) 2. Factory tested to a hydrostatic pressure of (Valve only) 500 psi (34.5 bar) for 2" (50mm), 21/2" (65mm), 76mm and 8" (200mm), 600 psi (41.4 bar) for 4" (100mm), 165mm & 6" (150mm). 3. End and trim connections: • ANSI/AWWA C606 dimensions: Nominal Outlet Groove Groove Outlet Face to Pipe Size Diameter Diameter Width Groove 2" (50 mm) 2.375" 2.250" 11/32" 5/8" (60mm) (57mm) (9.Omm) (16mm) 21/2" (65 mm) 2.875" 2.720" 11/32" 5/8" (73mm) (69mm) (9.Omm) (16mm) 76 mm 3.000" 2.845" 11/32" 5/8" (76mm) (72mm) (9.Omm) (16mm) 3" (80 mm) 3.500" 3.344" 11/32" 5/8" (89mm) (85mm) (9.Omm) (16mm) 4" (100 mm) 4.500" 4.334" 3/8" 5/8" (114mm) (11Omm) (9.5mm) (16mm) 165 mm 6.500" 6.330" 3/8" 5/8" (165mm) (161mm) (9.5mm) (16mm) 6" (150 mm) 6.625" 6.455" 3/8" 5/8" (168mm) (164mm) (9.5mm) (16mm) 8" (200 mm) 8.625" 8.441" 7/16" 3/4" (219mm) (214mm) (11mm) (19mm) Flange dimensions: FlanW Nominal Bolt Circle Circle Bok Hole Flange Outside Flange Number Type Sim Diameter Diameter DiameterASME of Bolts 41 7112" 3/4' 91 15/s B16.5 ClB16.50 ass (100mm) (191mm) (19mm) (229nm) (24mm) 8 ISO 4 73/ ' 3/a' 9" 15/19, 700&2 PN16 (100mm) (180mm) (19mm) (229rrm) (24rrm) 8 BASM5 6" 91/2 � 18�� 11 ° s/e 8 CIEM150 (150mm) (241mm) (22rm) (279rm) (24rrm) ISO �' 97/6'/' (150mm) (240rmi) (23nnn) (279rm) (24mm) 8 PN16 ASME 8" 113/a' 78" 131/2" 1" Class(200mm) 150 (298rrrn) (2am) (343mm) (25.4mm) 8 ISO 8" 1158" / ' 131/2" 1" 70016 (200mm) (295mm) (23rr m) (343mm) (25.4mm)F12 Threaded openings Per ANSI B 2.1 5. RELIABLE MODEL 131 ACCELERATOR KIT (P/N 6516000003) AIR PRESSURE GAUGE MODEL B1 ACCELERATOR NIPPLE, 1/2" x 2" ELBOW, 112" NOTE: A MINIMUM OF 15 PSI (1.0 BAR) OF SUPERVISORY AIR PRESSURE IS REQUIRED WHEN USING A MODEL B1 ACCELERATOR. 1 NIPPLE, 1/2" x 2" VENT TO ATMOSPHERE Fig. 3 'lOM MODEL EX 3Y PIPE VALVE 'YSTEM TRIM NIPPLE, 112" x 3" BALL VALVE, 1/2" SEE BULLETIN 323 FOR DETAILS 359FG04 A MODEL B HYDRAULIC MANUAL EMERGENCY STATION 00 0� o� FROM MODEL EX DRY PIPE VALVE NYLON TIE xm e W mT OF PLASTIC TUBING TO DRIPoSB CUP Fig. 4 6. 4. Valve Exterior's Color: Valve Size Color 2" 50 mm Black or Red 21/2" 65 mm Black or Red 76 mm Red 3" 80 mm Black or Red 4" 100 mm Black or Red 165 mm Red 6" 150 mm Black or Red 8" (200 mm) Black or Red 5. Face to face dimensions: Valve Size End Connection: End to End: 2" (50mm), 2112" (65mm), 76mm & 3" (80mm) Groove/ Groove 12112" (318mm) 4" (100mm) Groove/ Groove 14" (356mm) Flange/ Groove 16" (406mm) Flange/ Flange 16" 406mm 6" (150mm) & 165mm Groove/ Groove 16" (406mm) Flange/ Groove 19" (483mm) Flange/ Flange 19" 483mm 8" (200mm) Groove/ Groove 193/" (492mm) Flange/ Flange 211/4" (540mm) 6. Valve Shipping Weight: Valve Size: End Connection: Weight: 2" (50mm), 21/2" (65mm), 76mm & 3" (80mm) Groove/ Groove 34 Ibs (15 kg) 4" (100mm) Groove/ Groove 64 Ibs (29 k Flange/ Groove 79 Ibs (36 kg) Flange/ Flange 92 Ibs (42 kg) 6" (150mm) & 165mm Groove/ Groove 95 Ibs (43 kg) Flange/ Groove 122 Ibs (56 kg) Flange/ Flange 138 Ibs (69 kg) 8" (200mm) Groove/ Groove 148 Ibs (67 kg) Flange/ Flange 197 Ibs 90 kg) 7. Trim Shipping Weight: Valve Size: Weight: 2" (50mm), 2112" (65mm), 76mm 30 Ibs (13.6 kg) & 3" (80mm) 4" (100mm), 6" (150mm), 165mm 34 Ibs (15.5 kg) & 8" (200mm) 8. Friction loss (Expressed in equivalent length of Schedule 40 pipe, based on Hazen & Williams formula. Valve Size: E uivalent Length: Cv C 100 2" 50mm 4.4 ft 1,3 nn 3.1 ft 1,0 nn 101 21/2" 65mm 6.0 ft 1,8 m 4.3 ft 1,3 m 236 76mm 7.7 ft 2,3 m) 5.5 ft 1,7 m 241 3" 80mm 12.6 ft 3,8 nn 9.0 ft 2,7 nn 254 4" 100mm 14 ft 4,3 m 10 ft 3,0 m 469 165mm 29.4 ft 9,0 nn 20.9 ft 6,4 m 886 6" 150mm 29.4 ft 9,0 nn 20.9 ft 6,4 m 886 8" 200mm 53.5 ft 16,3 nn 38.1 ft 11,6 m 1516 9. Installation position: Vertical System Air or Nitrogen Pressure Requirements The system trim includes gauges to read the pneumat- ic and water pressures of Model EX Dry Valve. Table A specifies the air or nitrogen pressure level to be applied to the Model EX Dry Pipe Valve. Optional Reliable Model A-2 Pressure Maintenance Device (see Reliable Bulletins 254) automatically provides a safeguard against pressure leaks in the sprinkler piping, and properly restricts the flow of makeup air. When the optional Model B1 Accelerator is used, a Model A-2 Pressure Maintenance Device and a tank -mounted air compressor are required. Also, when a Model 131 Accelerator is used, to expedite water -delivery time, the pneumatic pressure must not be less than 15 psi (1.0 bar). Whenever multiple dry systems are installed at the same location, each dry system is to have its own Model A-2 Pressure Maintenance Device installed for individual maintenance of air pressure (Refer to the 2007 Edition of NFPA 13, section 7.2.6.5.3). Table A (For the fastest water transit time, use no more than the "Best Performance Max" pneumatic pressure) Water Pressure psi bar Pneumatic Pressure to be Pumped into Sprinkler Sy stem psi bar Maximum Not Less Than Best Performance Max 200.4) 8(0.6) 10(0.7) 30(2.1) 10(0.7) 14(1.0) 50(3.4) 12(0.8) 160.1) 75(5.2) 13(0.9) 170.2) 100(6.9) 150.0) 190.3) 125(8.6) 160.1) 200.4) 150 10.3 170.2) 210.4) 175 12.1 18(1.2) 22(1.5) 200 13.8 190.3) 230.6) 225 15.5 210.4) 250.7) 250 17.2 1 220.5) 260.8) 275 19.0 230.6) 27(1.9) 300 20.7 240.7) 280.9) Note: During system set-up, a higher pneumatic pressure may be re- quired in order to properly set the Model EX Dry Valve. Nitrogen used in refrigerated area systems minimizes a possibility of ice build-up and blockage inside the system piping that could inhibit proper system operation. The cal- culated nitrogen supply in Ibs (kg) to pressurize various system capacities to 10 psi (0.7 bar) at different freezer temperatures is as follows: System Freezer Tem erature °F °C Approx. Capacity 20 0 -20 -40 -60 Fill Time Gal. L (-6.7) (-18) (-29) (40) (-51) min* 250 1.90 1.90 2.00 2.10 2.20 1 946 0.86 0.86 0.91 0.95 1.00 500 3.64 2.80 4.00 4.20 4.40 2 1893 1.65 1.27 1.81 1.91 2.00 750 5.50 5.70 6.00 6.30 6.60 3 2839 2.49 2.59 2.72 2.86 2.99 1000 7.30 7.60 8.00 8.33 8.80 4 3785 3.31 3.45 3.63 3.78 3.99 Note: (1 bar =100 kPa) Consult Reliable Bulletin 357 for more detailed information. * When filled with the Reliable Model A-2 Pressure Main- tenance Device having the bypass valve open. 7. Patents U.S. Patent Pending for a Dry Pipe Valve Arrangement Ordering Information Specify: Valve Model, Size & End Connection — Valve Part Numbers Valve Size & End Connection Flange Type Color Reliable Part Number 2" (50mm) Grv/Gry N/A Black 6101021010 Red 6101021015 2'/z" (65mm) Grv/Gry N/A Black 6101025010 Red 6101025015 3" (80mm) Grv/Gry N/A Black 6101031010 Red 6101031015 76mm Grv/Gry N/A Red 6101051015 4" (100mm) Grv/Gry N/A Black 6101041010 Red 6101041015 4" (100mm) Flg/Gry ASME Class 150 Black 6101041020 ASME Class 150 Red 6101041025 ISO PN16 Red 6101041045 4" (100mm) Flg/Flg ASME Class 150 Black 6101041030 ASME Class 150 Red 6101041035 ISO PN16 Red 6101041055 6" (168mm) Grv/Gry N/A Black 6101061010 Red 6101061015 6" (168mm) Flg/Gry ASME Class 150 Black 6101061020 ASME Class 150 Red 6101061025 ISO PN16 Red 6101061045 6" (168mm) Flg/Flg ASME Class 150 Black 6101061030 ASME Class 150 Red 6101061035 ISO PN16 Red 6101061055 165mm Grv/Gry N/A Red 6101065015 165mm Flg/Gry ASME Class 150 Red 6101065025 ISO PN16 Red 6101065045 8" (200mm) Grv/Gry N/A Black 6101081010 Red 6101081015 8" (200mm) Flg/Flg ASME Class 150 Black 6101081030 ASME Class 150 Red 6101081035 ISO PN16 Red 6101081055 f:1 Trim — The trim set is available in individual parts, in time -saving segmentally assembled kit forms, or fully assembled to the Model EX Low Pressure Dry Pipe Valve (with or without a control valve). TRIM PART NUMBERS: 2" (50MM), 2-1/2" (65MM), 3" (80MM) & 76MM: INDIVIDUAL TRIM COMPONENTS (ASSEMBLY REQUIRED, EX VALVE NOT INCLUDED):6501030001 SEGMENTALLY ASSEMBLED TRIM (EX VALVE NOT INCLUDED):6501030002 4" (100MM), 6" (168MM), 165MM & 8" (200MM): INDIVIDUAL TRIM COMPONENTS (ASSEMBLY REQUIRED, EX VALVE NOT INCLUDED):6501060001 SEGMENTALLY ASSEMBLED TRIM (EX VALVE NOT INCLUDED):6501060002 FOR FULLY ASSEMBLED TO MODEL EX VALVE SEE THE PART NUMBER SCHEME BELOW: PART NUMBER SCHEME: MISC OPTIONS: 0: BLACK VALVE A: RED VALVE B: RED VALVE WITH DOMESTIC TRIM C: CHINESE MARKINGS ON VALVE D: BLACK VALVE WITH DOMESTIC TRIM EXAMPLE P/N: 650606 CONTROL VALVE/ACCELERATOR: 0: WITHOUT CONTROL VALVE, WITHOUT ACCELERATOR 1: WITH CONTROL VALVE, WITHOUT ACCELERATOR 2: WITHOUT CONTROL VALVE, WITH ACCELERATOR 3: WITH CONTROL VALVE, WITH ACCELERATOR 4: WITH CONTROL VALVE, WITH INLET SPOOL 5: WITH CONTROL VALVE, WITH INLET SPOOL AND ACCELERATOR NOTE: 76MM & 165MM NOT AVAILABLE WITH CONTROL VALVE. 4' (100MM), 6" (168MM) & 165MM WITH FLANGED INLET AND FLANGED OUTLET OR FLANGED INLET AND FLANGED OUTLET NOT AVAILABLE WITH CONTROL VALVE. 8" (200MM) WITH FLANGED INLET AND FLANGED OUTLET NOT AVAILABLE WITH CONTROL VALVE VALVE SIZE: 1: 2' (50MM) 2: 2-1/2' (65MM) 3: 3' (80MM) 4:4'(100MM) 5: 76MM 6: 6' (168MM) 7: 165MM 8: 8' (200MM) PRESSURE SWITCHES: 1: POTTER WITH APPROVALS 2: SYSTEM SENSOROR WITH WITH ULC APPROVALS 3: SYSTEM SENSOR WITH UL/FM APPROVALS 10 END CONNECTION: 1: GROOVED INLET, GROOVED OUTLET 2: CLASS 150 FLANGED INLET, GROOVED OUTLET 3: CLASS 150 FLANGED INLET, CLASS 150 FLANGED OUTLET 4: PN16 FLANGED INLET, GROOVED OUTLET 5: PN16 FLANGED INLET, PN16 FLANGED OUTLET NOTE: 2" (50MM), 2-1/2' (65MM), 3" (80MM) & 76MM NOT AVAILABLE WITH FLANGED INLET AND FLANGED OUTLET OR FLANGED INLET AND FLANGED OUTLET. 8' (200MM) NOT AVAILABLE WITH FLANGED INLET AND GROOVED OUTLET THE EXAMPLE IS A BLACK 6" (168MM) VALVE WITH POTTER PRESSURE SWITCHES, WITHOUT A CONTROL VALVE, WITHOUT AN ACCELERATOR AND HAS A GROOVED INLET AND GROOVED OUTLET Fig. 5 359FG11B N Additional equipment Component Part Mfgr. Description Technical Bulletin Water Supply Control Valve Select OS&Y Butterfly, Tamper Switch (Optional) for OS&Y Valve B Model OS&Y2 Potter 5400928 Tamper Switch (Optional) for Butterfly Valve Model P1 BV2 Potter 5400928 Dry Pipe Valve A Model EX Reliable 358/359 Dry Pipe Valve System A Refer to Parts in this Bulletin Reliable 358/359 Waterflow Alarm Pressure Switch B Model PS10-2 (DPDT cULus, FM) Potter 5400928 Model PS10-2 (DPDT VdS) Low Air Alarm Pressure Switch B Model PS25-2 (DPDT cULus, FM) Potter 5401564 Model PS25-2 (DPDT VdS) Mechanical Alarm (Optional) A Model C Reliable 612/613 Manual Emergency Station A Model A Hydraulic (Pilot Line) Type Reliable 506 Sprinklers A Closed Type Reliable 110, 117, 131, 136, etc. Air Compressor" C Per NFPA 13 F-30 Pressure Maintenance Device A Model A-2 Reliable 254 Accelerator Kit" A Model B1 Reliable 323 Nitrogen Regulating Device A Regulator with Optional Low Air Pressure Switch Reliable 254 *If the optional Model 131 Accelerator is used, a tank -mounted air compressor and an A-2 pressure maintenance device must be provided. Additionally the use of a tank -mounted air compressor helps to eliminate on/off compressor cycling that may occur as a result of small leakage in the air line between the pressure maintenance device and the 1/2" check valve, as well as due to ambient temperature changes in the system piping. System Equipment Manufacturers (A) Reliable Automatic Sprinkler Co., Inc. (B) Potter (C) Gast Manufacturing Corp. 10. Nominal Installation Dimensions in Inches (mm) Pipe Size A B C D* D** D*** D**** D***** E F G H I J K L M N P Q 2" (50 mm) 81/2 7 71/2 121/2 153/4 211/4 N/A N/A 10'/4 203/4 121/2 41/2 83/4 63/4 71/4 63/4 16 6 11 93/4 (216) (178) (191) (318) (400) (540) (260) (527) (318) (114) (222) (171) (184) (171) (406) (152) (279) (248) m ((65 3" & 80 mm) 81/2 7 71/2 121/2 161/2 22 N/A N/A 10'/4 203/4 121/2 41/2 83/4 63/4 7'/4 63/4 16 6 11 93/4 76 mm (216) (178) (191) (318) (419) (559) (260) (527) (318) (114) (222) (171) (184) (171) (406) (152) (279) (248) 4" (100 mm) 81/2 71/2 71/2 14 183/4 24'/4 16 16 111/2 22 15'/4 5'/2 93/4 73/4 8 101/2 171/2 6 11 113/4 (216) (191),(191) (356) (476) (616) (406),(406) (292) (559),(387) (140) (248) (197) (203) (267) (445) (152) (279) (298) 6" (150 mm) 81/2 8 71/2 16 211/4 263/4 19 19 13'/4 233/4 16 51/2 10'/4 8 10 11 191/2 6 11 113/4 & 165 mm (216) (203) (191) (406) (540) (679) (483) (483) (337) (603) (406) (140) (260) (203) (254) (279) (495) (152) (279) (298) 8" (200 mm) 8'/2 81/2 7'/2 193/8 25'/4 303/4 N/A 21'/4 131/2 24 16'/2 51/2 12'/4 9 71/2 12'/4 19'/4 6 11 113/4 (216) (215) (191) (492) (641) (781) (540) (343) (610) (419) (140) (311) (229) (191) (311) (489) (152) (279) (298) D* is the takeout for a Grv/Gry EX valve only. D** is the total takeout for a Grv/Gry EX valve with a Reliable control valve or, for 2" (50 mm) valves only, Anvil control valve. Substituting a NIBCO control valve increases the total takeout to 22" (559 mm) for a 6" (150 mm) valve and reduces the total takeout to 243/4" (629 mm) for an 8" (200 mm) valve. D*** is the total takeout for a Grv/Gry EX valve with an Inlet Spool and a Reliable control valve or, for 2" (50 mm) valves only, Anvil control valve. Substituting a NIBCO control valve increases the total takeout to 271/2" (698 mm) for a 6" (150 mm) valve and reduces the total takeout to 30'/4" (769 mm) for an 8" (200 mm) valve. D**** is the takeout for a Flg/Gry EX valve only. D***** is the takeout for a Flg/Flg EX valve only. 11. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. JCX Recycled ® (800) 431-1588 Sales Offices Paper RelsiablL (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/16 P/N 9999970426 CP� POTTER The Symbol of Protection ©,.POTri Sr. Louis, Missouri e®wMoaei "umber / C �i PS10-2 \C Ordering Information Model Description Stock No. PS10-1 Pressure switch with one set 1340103 SPDT contacts PS 10-2 Pressure switch with two sets 1340104 SPDT contacts Hex Key 5250062 Cover Tamper Switch Kit 0090200 Tamper Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090200. See bulletin #5401200 PSCTSK. Installation The Potter PS10 Series Pressure Actuated Switches are designed for the detection of a waterflow condition in automatic fire sprinkler systems of particular designs such as wet pipe systems with alarm check valves, dry pipe, preaction, or deluge valves. The PS10 is also suitable to provide a low pressure supervisory signal; adjustable between 4 and 15 psi (0,27 and 1,03 BAR). 1. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) 2. Device should be mounted in the upright position (threaded connection down). 3. Tighten the device using a wrench on the flats on the device. Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. Carefully place a screwdriver on the edge of the knockout and sharply apply a force sufficient to dislodge the knockout plug. See Fig 9 3. Run wires through an approved conduit connector and affix the connector to the device. 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5, and 6. See Fig 7 for two switch, one conduit wiring. Testing The operation of the pressure alarm switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Wet System Method 1: When using PS10 and control unit with retard - connect PS10 PS10 SERIES PRESSURE SWITCH UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Dimensions: 3.78" (9,6cm)W x 3.20" (8,lcm)D x 4.22" (10,7cm)H Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screws suitable for dissimilar voltages. Enclosure: Cover - Die-cast with textured red powdercoat finish, single cover screw and rain lip. Base - Die-cast Pressure Connection: Nylon 1/2" NPT Male Factory Adjustment: 4 - 8 PSI (0,27 - 0,55 BAR) Differential: 2 PSI (0,13 BAR) typical Maximum System Pressure: 300 PSI (20,68 BAR) Switch Contacts: SPDT (Form C) 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC One SPDT in PS10-1, Two SPDT in PS10-2 Environmental Specifications: NEMA 4/IP66 Rated Enclosure - indoor or outdoor when used with NEMA 4 conduit fittings. Temperature range: -40°F to 140OF (-40°C to 60°C) Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential Occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 into alarm port piping on the input side of retard chamber and electrically connect PS 10 to control unit that provides a retard to compensate for surges. Insure that no unsupervised shut-off valves are present between the alarm check valve and PS10. Method 2: When using the PS 10 for local bell application or with a control that does not provide a retard feature -the PS 10 must be installed on the alarm outlet side of the retard chamber of the sprinkler system. Testing: Accomplished by opening the inspector's end -of -line test valve. Allow time to compensate for system or control retard. Note: Method 2 is not applicable for remote station service use, if there is an unsupervised shut-off valve between the alarm check valve and the PS 10. Wet System With Excess Pressure Connect PS10 into alarm port piping extending from alarm check valve. Retard provisions are not required. Insure that no unsupervised shut-off valves are present between the alarm check valve and the PS10. Testing: Accomplished by opening the water by-pass test valve or the inspector's end -of -line test valve. When using end -of -line test, allow time for excess pressure to bleed off. Dry System Connect PS10 into alarm port piping that extends from the intermediate chamber of the alarm check valve. Install on the outlet side of the in -line check valve of the alarm port piping. Insure that no unsupervised shut-off valves are present between the alarm check valve and the PS10. Testing: Accomplished by opening the water by-pass test valve. Note: The above tests may also activate any other circuit closer or water motor gongs that are present on the system. Potter Electric Signal Company, LLC e St. Louis, MO e Phone: 866-956-0988/Canada 888-882-1833 e www.pottersignal.com PRINTED IN USA MFG. #5400928 - REV D-1 PAGE 1 OF 3 12/10 (E)POTTER The Symbol of Protection Dimensions Fig. 1 0OGROUND 2.87 SCREWS ADJUSTMENT ® [72.971 4 KNOB 22 [107.191 1/2" NPT 2.48 1.60 �1 162.871 [40.64] 3.78 3.20 [95.891 181.281 NOTE: To prevent leakage, apply Teflon tape sealant to male threads only. DWG# 930-1 Typical Sprinkler Applications Fig. 3 WET SYSTEM WITH EXCESS PRESSURE PS10 WATER MOTOR GONG RBVS WET SYSTEM ALARM CHECK VALVE OS&Y VALVE WATER BY-PASS VALVE PS10 SERIES PRESSURE SWITCH Switch Clamping Plate Terminal Fig. 2 �G 4% \/ d �GGG DWG# 923-3 0 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. WET SYSTEM WITHOUT DRY SYSTEM EXCESS PRESSURE PS10 PS10 WATER WATER MOTOR MOTOR � GONG GONG CHECK RBVS DRY VALVE RBVS WET SYSTEM SYSTEM ALARM ALARM CHECK CHECK RETARD VALVE VALVE WATER WATER OS & Y BY-PASS OS & Y BY-PASS VALVE VALVE VALVE VALVE DWG. #923-2AA A CAUTION Closing of any shutoff valves between the alarm check valve and the PS 10 will render the PS 10 inoperative. To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. Low Pressure Signal Connection Fig. 4 TO FHtE ALARM PANEL O O] Waterflow Signal Connection Fig. 5 Local Bell For Waterflow Connection Fig. 6 NEGATIVE DC OR NEUTRAL A( POSITIVE Di OR HOT AC PRINTED IN USA MFG. #5400928 - REV D-1 PAGE 2 OF 3 12/10 (E)POTTER > The Symbol of Protection One Conduit Wiring Fig. 7 Break out thin section of divider to provide path for wires when wiring both switches from one conduit entrance. WARNIN Fig. 8 Terminal W/ PRESSURE APPLIED C: Common 1: Closed when installed under normal system pressure. 2: Open when installed under normal system pressure. Closes on pressure drop. Use for low pressure supervision. ------------------------------- Terminal W/O PRESSURE APPLIED 1: Open with no pressure supplied. Closes upon detection of pressure. Use for waterflow indication. rol 2: Closed with no 1 pressure applied. •Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. -Shock hazard. Disconnect power source before servicing. Serious injury or death could result. -Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. -Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. Engineer/Architect Specifications Pressure Type Waterflow Switch Pressure type waterflow switches; shall be a Model PSI 0 as manufactured by Potter Electric Signal Company, St Louis MO., and shall be installed on the fire sprinkler system as shown and or specified herein. Switches shall be provided with a'/2" NPT male pressure connection and shall be connected to the alarm port outlet of, Wet Pipe Alarm Valves, Dry Pipe Valves, Pre -Action Valves, or Deluge Valves. The pressure switch shall be actuated when the alarm line pressure reaches 4 - 8 PSI (0,27 - 0,55 BAR). Pressure type waterflow switches shall have a maximum service pressure rating of 300 PSI (20,68 BAR) and shall be factory adjusted to operate on a pressure increase of 4 - 8 PSI (0,27 - 0,55 BAR) PS10 SERIES PRESSURE SWITCH Removing Knockouts Fig. 9 7"� 8 CAUTION ....., ' .d-5 -Do not tighten by grasping the switch enclosure. Use wrenching flats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. -To seal threads, apply Teflon tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. -Do not over tighten the device, standard piping practices apply. Pressure switch shall have one or two form C contacts, switch contact rating 10.1 Amps at 125/250 VAC, 2.0 Amps at 30 VDC. Pressure type waterflow switches shall have two conduit entrances one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure type waterflow switch shall be Zinc die-cast with rain lip and shall attach with one tamper resistant screw. The Pressure type waterflow switch shall be suitable for indoor or outdoor service with a NEMA 4/IP66 rating. The pressure type waterflow switch shall be UL Ulc and CSFM listed, FM and LPC approved and NYMEA accepted. PRINTED IN USA MFG. #5400928 - REV D-1 PAGE 3 OF 3 12/10 (E)POTTER ® The Symbol of Protection Ordering Information Model Description Stock No. PS40-1 Pressure switch with one set SPDT contacts 1340403 PS40-2 Pressure switch with two sets SPDT contacts 1340404 Hex Key 5250062 Cover Tamper Switch Kit 0090200 BVL Bleeder valve 1000018 Installation The Potter PS40 Series Pressure Actuated Switches are designed primarily to detect an increase and/or decrease from normal system pressure in automatic fire sprinkler systems. Typical applications are: Dry pipe system, pre -action air/nitrogen supervision, pressure tanks, air supplies, and water supplies. The PS40 switch is factory set for 40 PSI (2,8 BAR) normal system pressure. The switch marked with the word LOW is set to operate at a pressure decrease of 10 PSI (,7 BAR) at 30 PSI (2,1 BAR). The switch marked with the word HIGH is set to operate at a pressure increase of 10 PSI (,7 BAR) at 50 PSI (3,5 BAR). See section heading Adjustments and Testing if other than factory set point is required. 1. Connect the PS40 to the system side of any shutoff or check valve. 2. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) 3. Device should be mounted in the upright position. (Threaded connection down) 4. Tighten the device using a wrench on the flats on the device. Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. Carefully place a screwdriver on the edge of the knockout and sharply apply a force sufficient to dislodge the knockout plug. See Fig. 9 3. Run wires through an approved conduit connector and affix the connector to the device. A NEMA-4 rated conduit fitting is required for outdoor use. PS40 SERIES PRESSURE SWITCH (UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Pending) Dimensions: 3.78" (9,6cm)W x 3.20" (8,lcm)D x 4.22" (10,7cm)H Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screw suitable for dissimilar voltages Enclosure: Cover- Die-cast with textured red powdercoat finish, single cover screw and rain lip. Base- Die-cast Pressure Connection: Nylon 1/2" NPT male Factory Adjustment: PS40-1 operates on decrease at 30 PSI (2,1 BAR) PS40-2 operates in increase at 50 PSI (3,5 BAR) and on decrease at 30 PSI (2,1 BAR) Pressure Range: 10-60 PSI (,7 - 4,1 BAR) Differential: Typical 1 lb. at 10 PSI (,07 at ,7 BAR) 4 lbs at 60 PSI (,28 at 4,1 BAR) Maximum System Pressure: 300 PSI (20,68 BAR) Switch Contacts: SPDT (Form C) 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC One SPDT in PS40-1, Two SPDT in PS40-2 Environmental Specifications: NEMA 4/IP55 Rated Enclosure - indoor or outdoor when used with NEMA 4 conduit fittings. Temperature range: -40°F to 140°F (-40°C to 60°C) Tamper: Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090200. See bulletin #5401200 PSCTSK. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential Occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5,6, and 8 Adjustment And Testing The operation of the pressure supervisory switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Note: Testing the PS40 may activate other system connected devices. The use of a Potter BVL (see product bulletin 8900067 for details) is recommended to facilitate setting and testing of the PS40 pressure switch. When a BVL (bleeder valve) is used, the pressure to the switch can be isolated and bled from the exhaust port on the BVL without effecting the supervisory pressure of the entire system. See Fig. 3 The operation point of the PS40 Pressure Switch can be adjusted to any point between 10 and 60 PSI (0,7 - 4,11 BAR) by turning the adjustment knob(s) clockwise to raise the actuation point and counter clockwise to lower the actuation point. In the case of the PS40-2, both switches operate independent of each other. Each switch may be independently adjusted to actuate at any point acrosss the switch adjustment range. Initial adjustment can be made with a visual reference from the top of the adjustment knob across to the printed scale on the switch bracket. Final adjustments should be verified with a pressure gauge. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5400930 - REV D PAGE 1 OF 3 1/08 (E)POTTER ® The Symbol of Protection Dimensions Fig. 1 00 SCREWGROUNS 2.87 ADJUSTMENT [72.971 KNOB ® 4.22 [107.19] 1/2" NPT 2.48 1.60 162.871 [40.641 3.78 3.20 [95.891 [81.281 NOTE.: To prevent leakage, apply Teflon tape sealant to male threads only. DWG# 930-1 Typical Sprinkler Applications Fig. 3 PS40 AIRLINE SHUT-OFF PS 10 VALVE BLEEDER ALARM TEST PRESSURE CHECK VALVE SWITCH VALVE BVL CHECK RBVS DRY PIPE VALVE VALVE WATER DWG. #924-1A BY-PASS OS & Y TEST VALVE VALVE Typical Connections Fig. 4 WITH NORMAL SYSTEM PRES- PS40-1 SURE APPLIED LOW -TERMINAL 2 CLOSES ON PRESSURE DROP. TO FIRE ALARM PANEL WATER MOTOR GONG TO F ALA PAN PS40 SERIES PRESSURE SWITCH Switch Clamping Plate Terminal Fig. 2 NCO d� G04y0 DWG# 923-3 lls 'WAWARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. A CAUTION Closing of any shutoff valves between the alarm check valve and the PS 10 will render the PSI 0 inoperative. To comply with NFPA- 72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. PS40-2 HIGH AIR LOW WITH NORMAL SYSTEM AIR PRESSURE APPLIED HIGH - TERMINAL 1 WILL CLOSE ON PRESSURE INCREASE. DWG# 930-2 PRINTED IN USA MFG. #5400930 - REV D PAGE 2 OF 3 1 /08 (E)POTTER P The Symbol of Protection Low Pressure Signal Connection High Pressure Signal Connection Fig. 5 1 Fig. 6 TO FIRE ALARM PANEL 0 0 DWGN 926-1 Changing Pressure (With normal system pressure) Fig. 8 Terminal LOW PRESSURE SWITCH C: Common NC 1: Closed when installed under normal system c pressure. p 2: Open when installed bll �blblblq under normal system pressure. Closes on c , 2 pressure drop. Use for low air signal. ------------------------------- Terminal 1: Open when installed under normal system pressure. Closes on increase in pressure. Use for high air signal. 2: Closed under normal system pressure. HIGH PRESSURE SWITCH NC "0--] f C 1 2 DWG# 930-3 TO FIRE ALARM PANEL 0 0 Removing Knockouts Fig. 9 Engineer/Architect Specifications Pressure Type Waterflow Switch Pressure type supervisory switches; shall be a Model PS40 as manufactured by Potter Electric Signal Company, St. Louis, MO., and shall be installed on the fire sprinkler system as shown and or specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Company of St. Louis, MO., or equivalent shall be connected in line with the PS40 to provide a means of testing the operation of the supervisory switch. (See Fig. 3) The switch unit shall contain SPDT (Form C) switch(es). One switch shall be set to operate at a pressure decrease of 10 PSI (0,7 BAR) from normal. If two switches are provided, the second switch shall be set to operate at a pressure increase of 10 PSI (0,7 BAR) from normal. Switch contacts shall be rated at 10.1 Amps at 125/250VAC and 2.0 Amps at 30VDC. The units shall have a maximum pressure rating of 300 PSI (20,68 BAR) and shall be adjustable from 10 to 60 PSI (0,7 to 4,1 BAR). Pressure switches shall have two conduit entrances, one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure switch shall be zinc die-cast with rain lip and shall attach with one tamper resistant screw. The pressure switch shall be suitable for indoor or outdoor service with a NEMA-4/I1`55 rating. The pressure switch shall be UL, ULC, and CSFM listed, FM and LPC approved and NYMEA accepted. Ll w utr7cd-5 PS40 SERIES PRESSURE SWITCH One Conduit Wiring Fig. 7 Break out thin section of divider to provide path for wires when wiring both switches from one conduit entrance. AWARNING -Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. -Shock hazard. Disconnect power source before servicing. Serious injury or death could result. -Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. -Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. A CAUTION -Do not tighten by grasping the switch enclosure. Use wrenching flats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. -To seal threads, apply Teflon tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. -Do not over tighten the device, standard piping practices apply. PRINTED IN USA MFG. #5400930 - REV D PAGE 3 OF 3 1 /08 Bulletin 251 Rev. T Models A-2 & B-1 Automatic Pressure Maintenance Devices Instructions for Installation, Operation, Care and Maintenance Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Operation Adjustment • Model A-2 Pressure Maintenance Device (Refer to Figure 1) The Model A-2 Pressure Maintenance Device (PMD) is de- signed for use where a source of compressed air (plant air system, tank -mounted compressor with a pressure control, etc.) or nitrogen cylinder (equipped with a regulating de- vice) is available (refer to the section in this technical bulle- tin titled "Installation"). The regulator in the Model A-2 PMD reduces higher pressure air or nitrogen to a level required by a dry pipe valve, dry pilot line, or a deluge valve based preaction system. The Model A-2 PMD will maintain a con- stant pressure in the system regardless of any pressure fluctuations from the compressed air or nitrogen source. Basic functionality of components (refer to Figure 1)The strainer's (Item 2) function is to prevent any foreign matter that may be present in the air supply, from traveling to the regulator (Item 1) and the check valve (Item 3), thereby en- suring their normal operation. The check valve's function is to prevent the reverse flow of water resulting from a dry pipe or deluge valve's operation, from reaching the regulator. The globe valves (Item 4) allow for the servicing (if needed) of the strainer (Item 2) and regulator (Item 1) without having to shut down the sprinkler system. The ball valve (Item 5) permits the rapid restoration (quick -fill) of the required sys- tem air pressure after service or operation. The ball valve (Item 5) must be closed and the globe valves (Item 4) must be open for proper automatic operation. • Models B-1 Pressure Maintenance Device (Refer to Figure 2) The Model B-1 Pressure Maintenance Device (PMD) is designed for use in conjunction with the Reliable Model A Tankless Air Compressor in order to maintain the correct air pressure in a dry pipe valve or dry pilot line (refer to the section in this technical bulletin titled "Installation"). The Re- liable Model A Tankless Air Compressor is controlled on or off by the air pressure level present in the dry pipe valve or dry pilot line via wiring between the compressor's motor and the contacts of the Model B-1 PMD's pressure switch. Basic functionality of components (referto Figure 21 A drop in the sprinkler system's air pressure causes the contacts of the pressure switch (Item 1) to close, thereby activating the air compressor. When the pre -adjusted level of air pressure is restored, the pressure switch's contacts re -open, thereby deactivating the air compressor. The pressure switch (Item 1) is also equipped with an unloader valve that automati- cally bleeds off the air compressor's outlet pressure each time the contacts of the pressure switch open. This protects the air compressor's motor from overloading during start- up. Like the Model A-2 PMD, the Model B-1 has a strainer (Item 2) for contamination control and a check valve (Item 3) to prevent reverse water flow. The ball valve (Item 5) and globe valves (Item 4) are also identical in configuration and function as with the Model A-2 PMD. Likewise, the ball valve (Item 5) must be closed and the globe valves (Item 4) must be open for proper automatic operation • Model A-2 Pressure Maintenance Device (Refer to Figure 1) The pressure regulator (Item 1) is factory set to maintain a nominal system air or nitrogen pressure of 30 psi (2,1 bar). In order to change the outlet pressure, loosen the locknut at the top of regulator and turn the adjustment screw clockwise to increase pressure. To decrease the pressure, turn the adjusting screw counter clockwise. The resulting pressure can be determined at the sprinkler system air gauge once the air flow through the device has ceased, or at the optional gauge location. Shown on Figure 1. Note: The Iocknut of the regulator (Item 1) must be tight- ened after adjusting in order to prevent an accidental change in the pressure setting. Adjustable Outlet Pressure Range: 5 psi to 100 psi (0.34 bar to 6.9 bar) Maximum Inlet Pressure: 175 psi (12 bar) • Model B-1 Pressure Maintenance Device The pressure switch (Item 1) is factory set to maintain a nominal system air pressure of 35 psi (2,4 bar). In order to change the setting, remove the pressure switch's cov- er and follow the directions contained within the switch. Electrical Ratina: Single Phase: 120 Volts AC; 2 hp 240 Volts AC; 3 hp 600 Volts AC; 5 hp Three Phase: 240 Volts AC; 5 hp 600 Volts AC; 5 hp 115-230 Volts DC; 3 hp Adjustable Outlet Pressure Range: 14 psi - to - 60 psi (1,0 bar - to - 4,1 bar) Maximum Inlet Pressure: 175 psi (12 bar) Listings and Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada. (ULC) 3. Certified by FM Approvals. 4. NYC MEA 258-93-E. 2. Model A-2 Pressure Maintenance Device P/N 6304000135, (All steel pipe fittings are galvanized) Item to Part No. Description Reo d Q' 1 98681630 Regulator, 5-100 psi 1 2 98727606 Strainer, 1/4" NPT, 90 1 3 96816902 Check Valve,'/4" 1 4 98840172 Globe Valve, 1/4" 2 5 98840108 Ball Valve, 3/4" 1 6 98815201 Union, 1/4" 1 7 96606616 Tee, 3/4" x 3/4" x 1/4" 2 8 98543234 Nipple, 3/4" x 31/2" 1 9 98543226 Nipple, 1/4" x 11/2" 5 10 98174404 Elbow, 1/4" 1 11 98543227 Nipple, 1/4" x Close 2 12 96606608 Tee, 1/4" 1 13 98614403 Plug, 1/4" 1 14 98543231 Nipple, 3/4 x 3" 1 Model B-1 Pressure Maintenance Device P/N 6304010100, (All steel pipe fittinqs are galvanized) item Nem Part No. Description Reo d q' 1 98728801 Pressure Switch, 3/8" NPT 1 2 98727607 Strainer, 1/4", 30 Mesh 1 3 96816902 Check Valve, 1/4" 1 4 98840172 Globe Valve, 1/4" 2 5 98840108 Ball Valve, 3/4" 1 6 98815201 Union, 1/4" 1 7 96606616 Tee, 3/4" x 3/4" x 1/4" 2 8 98543232 Nipple, 3/4" x 2 " 1 9 98543226 Nipple, 1/4" x 11/2" 5 10 96606608 Tee, 1/4" 1 11 98750004 Cross, 1/4" 1 12 98543227 Nipple, 1/4" x Close 1 13 98523100 Restriction Nipple, 1/4" 1 14 98768000 Copper Tubing, 1/4" O.D. 1 15 98085630 Comp. Fitting, 1/4" x 1/4" 1 16 98048034 Reducer Bushing 3/8" x 1/4" 1 17 98614403 Plug, 1/4" 1 18 98543231 Nipple, 3/4" x 3" 1 11 10 2 11 6 9 9 1 Optional 1 313 Pneumatic Pressure Gauge FroitiAir 14 ® Location or Nitrogen 9 Supply 12 9 7 4 8 9 5 14 To 7 System 251FG01D Figure 1 14 15 9 �9 1 10 2 13 9 4 16 12 6 3 Fro9 11 9 17 m 'ankles. 4 Compressor 7 9 18 5 251FG02D 8 TO 251FG01D 7 System Figure 2 3. Inspection and Maintenance Refer to Figures 1 & 2. 1. Review the latest NFPA 13 and NFPA 25 Standards, any appropriate dry pipe or deluge valve installation bulletins, and the section in this bulletin titled "Instal- lation" to ensure that the pressure maintenance de- vice is installed properly. 2. Make sure that both '/4" globe valves (Item 4) are open and that the 3/4" ball valve (Item 5) is closed. 3. Check the gas pressure in the dry pipe, deluge or preaction system at the pressure gauge located on those devices. See the section titled "Adjustment" if any are required. 4. If maintenance is to be performed on Items 1, 2 or 3 of the pressure maintenance device, make sure that both globe valves (Item 4) are closed and that pressure has been relieved from the section through the union (Item 6). These valves must be opened again in order to restore proper automatic operation. 5. The strainer (Item 2) should be cleaned periodically to prevent contamination from blocking air flow. This can be done by removing the strainer's cap and wip- ing or blowing off any collected debris. 6. Make sure the check valve (Item 3) is installed ac- cording to the schematic with the arrow on its hex- agonal side pointing in the required direction of air flow. 7. If the regulator (Item 1) in the Model A-2 Pressure Maintenance Device is constantly leaking at the ad- justing screw, the regulator may contain dirt keep- ing the poppet open and should be cleaned or re- placed. 8. Check the inside housing of pressure switch (Item 1) of the Model B-1 Pressure Maintenance Device for dirt or foreign matter and verify that the wiring is fastened securely and is wiring insulation is in good condition. WARNING: Do not contact the electrical wiring when the power is on Installation As shown in Figures 4 through 13, Pressure Maintenance Devices are installed in the air supply line leading to the dry pipe valve, deluge or preaction systems. With the Model A-2 PMD the air supply is a tank mounted compressor with a pressure control switch, or a Nitrogen supply equipped with a regulating device. With the Model B-1 PMD, the air supply is an air compressor without a pressure control switch. An extra outlet connection is provided on all of the models for mounting an optional pressure gauge to moni- tor the outlet pressure. Model A-2 Pressure Maintenance Device a. Make sure the air flow through the Pressure Maintenance Device is as shown by the arrows in Figures 1, 4, 6, 8, 9 and 11-13. b. Install the Pressure Maintenance Device as close to the dry pipe valve air line trimmings as pos- sible. Install the Pressure Maintenance Device in the air supply immediately leading to the del- uge or preaction trim. Refer to separate dry pipe valve, deluge valve or preaction system bulletins for the additional installation information. Model B-1 Pressure Maintenance Device a. Make sure the air flow through the Device is as shown by the arrows in Figures 2, 5-7 and10. b. Remove the pressure switch's (Item 1) cover and connect the wiring in accordance with the Nation- al Electric Code or other appropriate standards. The connections should be as shown in Figure 3 for single phase wiring of thermally protected compressor motors. Refer to separate dry pipe valve and deluge valve bulletins for additional in- stallation information. Air Compressor (REF. WIRING DIAGRAM ATTACHED TO AIR COMPRESSOR) 251FG04F Figure 3 For 3-phase wiring, a listed and/or approved, properly sized magnetic motor starter with ap- propriate NEMA enclosure must be provided. The wiring of the pressure switch, motor starter, and air compressor must be in accordance with the National Electrical Code, or other appropri- ate standards. E Model A-2 Pressure Maintenance Device with Model D Dry Pipe Valve Trim Pressure Maintenance / Device IG/ Pressure Relief / Valve 0 From Owner's Air Supply, Tank -Mounted Air Compressor or Nitrogen Supply Standard Dry Pipe Valve Air Line Trim Figure 4 Model D Dry Pipe Valve 251FG05G Model B-1 Pressure Maintenance Device with Model D Dry Pipe Valve Trim Electrical Signal To Compressor From Tankless Air Compressor Model B-1 Pressure Maintenance Device Standard Dry Pipe Valve Air Line Trim Pressure Relief Valve 1 Model D Dry Pipe Valve 251 FG06F Figure 5 5. "I 1 ,^ Model A-2 Pressure Maintenance Device with Model BX Dry Pilot Line Deluge Trim To Dry Pilot Line Pressure I /Switch ,( Pressure / Relief Valve mm mm From Owner's Air Supply, Dry Pilot Line Tank -Mounted Air Compressor Actuator Model BX or Nitrogen Supply Deluge Valve Model A-2 Pressure Maintenance Device � li Standard O O Dry Pilot Line � i Deluge Trim J 251FG07C Figure 6 Model B-1 Pressure Maintenance Device with Model BX Dry Pilot Line Deluge Trim Electrical Signal To Compressor To Dry Pressure Pilot Line Switch Pressure Relief i Valve a� DO mm From Tankless Dry Pilot Line Air Compressor %� Actuator Model BX Deluge Valve Model B Pressure Maintenance Device � li l Standard Dry Pilot Line �1 l� , Deluge Trim J O O 251FG08B Figure 7 6. Model A-2 Pressure Maintenance Device with Model LDX Dry Pipe Valve Trim From Owner's Air Supply, Tank -Mounted Air Compressor or Nitrogen Supply Model A-2 Pressure Maintenance Device 1 4 Model LOX Pressure Relief Check Valve Valve t ® V 1 40 _ n Model LDX Dry Valve Model LOX Actuator Dry Pipe Valve 251FG09B Figure 8 Model A-2 Pressure Maintenance Device with Model DDX Dry Pilot Line Deluge Trim From Owner's Air Supply, Tank -Mounted Air Compressor or Nitrogen Supply Model A-2 Pressure Maintenance Device A�r_ ToDry Pilot Line Pressure Switch Model LP Dry Pilot Line Actuator Model DDX Deluge Valve O 251 FG 10B Figure 9 7. Model B-1 Pressure Maintenance Device with Model DDX Dry Pilot Line Deluge Trim Model B-1 Pressure Maintenance From Tankless Device Air Compressor Electrical Signal To Compressor 00 1 To Dry Pilot Line Pressure Switch Model LP Dry Pilot Line Actuator Model DDX Deluge Valve 4W O O O 251FG11B Figure 10 Model A-2 Pressure Maintenance Device with Model DDX Dry Pilot Line Single Interlock Preaction Trim Model A-2 Pressure Maintenance Device � o Model DDX From Owner's Air Supply, Deluge Valve Tank -Mounted Air Compressor c�) or Nitrogen Supply 0 er Model LP Dry Valve Actuator O oa O 251FG12B Figure 11 91 Model A-2 Pressure Maintenance Device with Model DDX Type F Double Interlock Preaction Trim From Owner's Air Supply, Tank -Mounted Air Compressor or Nitrogen Supply Model A-2 Pressure Maintenance Device l R V / Model DDX Deluge Valve w Model LP Dry Valve Actuator O 00°0 251FG13B Figure 12 Model A-2 Pressure Maintenance Device with Model DDX- LP Dry Pipe Valve Trim From Owner's Air Supply, Tank -Mounted Air Compressor or Nitrogen Supply Model A-2 Pressure Maintenance Device 1 4 Model DDX Deluge Valve d� R Pur Model LP Q° Dry Valve Actuator O p d 251FG14B Figure 13 W Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/16 P/N 9999970040 af `� Y cornpis- Base Plate Mounted Standard Features ■ Heavy-duty single stage cast iron compressor pump Made in Somerset, PA USA ■ Splash lubricated ■ Belt driven with a large flywheel for extra cooling and easier start-up ■ Each unit is filled with Jenny Ultimate Blue Compressor Pump Oil ■ Directional air shroud for reduced pump temperatures ■ Totally enclosed heavy-duty belt guard ■ Powder coated, extra heavy steel base plate ■ Large canister intake filter with replaceable filter elements ■ Magnetic starter is included on all 5HP and larger units ■ Industrial/Commercial grade UL Listed electric motor ■ Thermal overload motor protection Base Mounted System Size Maximum Gallons in system to be pumped to 40 PSI in 30 Minutes Model Pump HP Power Supply 220 F13S-BS F12S-BS F34S-BS K34S-BS F1 S-BS K1 S-BS K15S-BS K2S-BS G2S-BS G3S-BS GC5S-BS J5S-BS F K F K G J 1/3 1/2 314 1 1-1/2 2 3 5 115 Volt (through 2 HP) or 230 Volt 1 Phase 208, 230, or 575 or 3 Phase 290 350 425 480 600 885 985 1215 1775 1950 2115 Tank Mounted/30 Gallon 220 F13S-30UMS F 1/3 290 F12S-30UMS 1/2 350 F34S-30UMS 3/4 425 K34S-30UMS K 480 F1S-30UMS F 1 600 K1S-30UMS K 885 K15S-30UMS 1-1/2 985 K2S-30UMS 2 1215 G2S-30UMS G 1775 G3S-30UMS 3 1950 GC5S-30UMS GC 5 2115 J5S-30UMS J 115 Volt (through 2 HP) 230 Volt 1 Phase 208, 230, 460 or 575 Volt 3 Phase Tank Mounted Additional Standard Features ■ Tanks are powder coated and ASME certified ■ Protectively mounted fittings ■ Manual tank drain(s) ■ Large canister intake filter with replaceable filter elements ■ Special unloading valves to assist in motor starting ■ Tank gauge ■ Pressure relief safety valve ■ Auto Start/Stop control with pressure unloader set at 25-40 PSI Pump CFM del'd @ RPM 40 PSI 670 2.9 Optional Auto Control Group ACGF 950 3.8 1200 4.4 520 5.3 ACGK 1430 6.0 ACGF 790 7.4 ACGK 1140 10.9 1280 12.4 630 15.1 ACGD 950 21.8 1030 24.2 ACGJ 830 26.0 670 2.9 950 3.8 1200 4.4 520 5.3 1430 6.0 790 7.4 1140 10.9 1280 12.4 630 15.1 950 21.8 1030 24.2 830 26.0 Options ASME National Board tank Magnetic starter 17 gallon tank ■ Vertical tank Low oil level switch ■ Oil sight glass Automatic tank drain ■ Air line filter Aftercooler ■ Dryer Control Group 7 Model 8000/8011 COMMERCIAL RISERPACK TM Pre -Assembled TESTANDRAIN° Riser Bronze: 1 W. 11/21 2 Sch. 40 Powder Coated: 21/2" 3" 4" 6" The AGF Commercial RISERPACK'" Model 8000/8011 are compact pre -packaged economical riser assemblies designed for NFPA 13 wet fire sprinkler systems. Every model utilizes an appropriate sized UL Listed/FM Approved patented AGF Model 2500 or 2511 TESTANDRAIN° valve designed to comply with NFPA 13 requirements requiring a sight glass for verification during testing through a properly sized orifice. All RISERPACKs'" are assembled with UL Listed/FM Approved AGF Model 7500 Pressure Gauge (300 PSI), Model 7600 1/4" 3-Way Globe Valve, and either a 1 " NPT or Saddle Mount Water Flow Switch as required by NFPA 13. The Model 8011 includes UL Listed/ FM Approved AGF Model 7000 Pressure Relief Valve (175 Rated); other ratings are available and may be substituted: 165, 185, 195, 205, 225, or 250. • 11/4", 11/2", and 2" Models are cast bronze with male threaded, grooved, or threaded x grooved ends. • 21/2", 3", 4", and 6" models are Schedule 40 steel with 3mil red powder coated finish and grooved ends • 300 PSI rating • Horizontal or Vertical Installation • 11/4", 11/2", and 2" models feature a 1 " FNPT M2500 or M2511 with available orifice sizes of %" to %" (ELO) • 21/2" and 3" models feature a 11/4" FNPT M2500 or M2511 with available orifice sizes of %" to 3/4" (ESFR) • 4" and 6" models feature a 2" grooved M2500 or M2511 with available orifice sizes of %" to K-25 The Model 2500/2511 TESTANDRAIN® valve offers a unique design benefit that allows system access through the valve for system integrity testing and/or installation of the optional relief valve trim kit (Model 8011) without draining the system. Model 8000 Bronze, Threaded Model 8000 Bronze, Thread x Groove Model 8011 Sch. 40 Powdercoated Model 8011 Bronze, Grooved Model 8000 Sch. 40 Powdercoated NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. SS-M8000M8011-COM • 02/14 TESTANDRAIN® and REMOTETESTO are registered trademarks of AGF Manufacturing Inc. Model 8000/8011 COMMERCIAL TM C&I RISERPACK 11/4"-2" Model 8000 11/4"-2" Model 8011 21h"-6" Model 8000 21h"-6" Model 8011 Loll I ICI IJKJI FJ SIZE A B C I D E 11/a" 14" 11 —F-2� 43/m ill, mm) (356 mm) (120 m141/2 (161/" 65(369 ) (279 mm) 11/2" 151/2" 141/4" I 43/4" I 63/4" (394 mm) (362 mm) (120 mm) (171 mm) (305 mm) 2" 151/2" 143/4" 5" 7" 12" (394 mm) (374 mm) (127 mm) (178 mm) (305 mm) 21/2" 171/8" 141/4" 55/8" 6" 14" (435 mm) (362 mm) (143 mm) (152 mm) (356 mm) 3„ 171/8" 15" 57/8" 63/8" 14" (435 mm) (381 mm) (149 mm) (162 mm) (356 mm) 411 * 171/8" 19" 8" 67/8" 14" (435 mm) (483 mm) (203 mm) (175 mm) (356 mm) 6" * 171/8" 211/8" 91/8" 77/8" 14" (435 mm) (537 mm) (232 mm) (200 mm) (356 mm) *4" and 6" RisERPACKs- feature a 2" groove x groove M2500/251 TESTANDRAIN® valve. Dimensions have been rounded to the nearest 1/4", except "E". Confirm that enough space is left between the RisERPACKT" and any obstructions to move handle of M2500/2511 TESTANDRAIN® valve into the "TEST" position and into the "DRAIN" position. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone:610-240-4900 Fax:610-240-4906 www.testandrain.com Components Item No. Part Qty. 1 RiserPACK - Bronze Casting 1 2 RiserPACK - Sch. 40 Powdercoated 1 3 M2500 TESTANDRAIN Valve 1 4 M2511 TESTANDRAIN Valve 1 5 M7000 Pressure Relief Valve 1 6 M7500 Pressure Gauge 1 7 M76001/4" 3-Way Globe Valve 1 8 Brass Nipple 1 9 Brass Nipple 1 10 1/4" Brass Plug 1 11 1/2" Brass NPT x Barb 90' Elbow 2 12 Clamps 2 13 Nylobraid Drain Tubing 1 14 NPT Water Flow Switch 1 15 Saddle Mount Water Flow Switch I 1 Job Name: Architect: Engineer: Contractor: n MADE IN U.S.A. 2' ; 2%' ; 65mm, 3' ; 4' ; VAL*2 this tomes .■.. FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION 6' ; 150mm & 8" MODEL RCV SWING CHECK VALVE STANDARD & "SHOTGUN" Globe Model RCV Swing Check Valves feature a swing type clapper designed for use in fire sprinkler or other types of water piping systems that incorporate grooved connecting pipe ends. They are effectively used when it is necessary to permit water flow in one direction only, preventing flow in the reverse direction (non -return). Because the RCV incorporates a spring -loaded clapper assembly, it may be installed in either the vertical position (upward flow only) or horizontal position (hinge pin to the top). Most commonly, it is used with various configurations of fire department connections for fire sprinkler systems, by-pass connections, grav- ity pressure tank and, pump discharge in connections from public water supplies to automatic sprinkler systems, etc. As an alternative to using an alarm check valve with a wet sprinkler system, an RCV Swing Check Valve may be used in a "Shotgun" arrangement whereby the valve is trimmed in a similar manner but utilizes an electric water flow switch and alarm bell instead of a water motor gong for fire notification. The body of the Globe RCV Swing Check Valve is constructed of high tensile strength cast iron having considerable ductility to reduce damage infield handling. It meets the ASTM A126 Class B rating. The RCV clapper assembly is made of stainless steel and has an E.P.D.M. rubber facing. It effectively provides a leak tight seal against back pressures greater than one (1) psi. APPROVALS cULus Listed FM Approved NYC -DOB MEA 305-05-E TECHNICAL DATA "A" OPTIONAL FOR RISER INSTALLATION Water Working Pressure Rating - 300 psi (20.7 bars) Factory Tested Hydrostatically to 600 psi (41.4 bars) Equivalent feet of pipe: 2", 2'/2" & 3" Valves = 7.2 feet, 4" Valve = 9.9 feet, 6" Valve = 16.1 feet, 8" Valve = feet MODEL RCV SWING CHECK VALVE PHYSICAL DIMENSIONS SIZE A C E F G H I J K L WEIGHT (Ibs.) no trim 2" 1" 4" 3 1/2" 4 1/2" 6 1/2" 1 1/2" 1 1/2" 2 1/4" 2 1/2" 4 3/4" 4.5 2 1/2" 1 1/4" 4 1/2" 4" 5" 7" 1 1/2" 1 1/2" 2 1/2" 2 3/4" 5 1/2" 8 65mm 1 1/4" 4 1/2" 4" 5" 7" 1 1/2" 1 1/2" 2 1/2" 2 3/4" 5 1/2" 8 3" 1 1/4" 5" 4 1/2" 6" 7 3/4" 1 3/4" 2" 3" 3 3/4" 6 3/4" 12 4" 2" 6 1/4" 4" 6 1/2" 8 1/2" 1 1/2" 2 1/2" 3 1/2" 4 1/4" 7 1/2" 17.5 6" 2" 8" 5" 8" 10 1/2" 1 1/2" 3 1/4" 4 1/4" 5 1/2" 10" 40.5 150mm 2" 8" 5' 8" 101/2" 11/2" 31/4" 41/4" 51/2" 10" 40.5 8" 2" 10" 7 3/4" 12 1/4" 15' 2 3/4" 4 3/4" 5 1/2" 7 1/4" 12 3/4" 74 FEBRUARY 2015 J-10 BULLETIN RCV, REV. #4 2'; 2%'; 65mm, 3-1; 4-1; 6' ; 150mm & 8" MODEL RCV SWING CHECK VALVE STANDARD & "SHOTGUN" CROSS SECTION ITEM DESCRIPTION MATERIAL 2" P/N 2 1/2" (65mm) 3" P/N 4" P/N 6" (150MM) 8" P/N P/N P/N 1 Hinge Pin Stainless 321521 321528 321535 321541 321549 321574 Steel 2 Torsion Spring Stainless 321523 321531 321531 321545 321554 321573 Steel 3 Machined Body Cast Iron 321501 321503 321505 321507 321509 321511 (DIN) (321503-D) (321509-D) 4 1/2"NPT Plug Cast Iron 311003 311003 311003 311003 311003 311003 5 Seat Ring Brass 321522 321530 321537 321543 321551 321575 6 Locknut Stainless 321556 321556 321556 321556 321556 321556 Steel 7 Nameplate Aluminum 321558 321558 321558 321558 321558 321558 8 Clapper Stainless 321515 321527 321534 321540 321548 321570 Steel Clapper Facing 9 Disc EPDM 321516 321529 321536 321542 321550 321571 10 Sealing Washer Hard Fiber 321518 321518 321518 321518 321518 321518 11 Disc Retainer Stainless 321517 321517 321517 321544 321544 321544 Steel 12 Hex Head Bolt Stainless 321519 321519 321555 321555 321559 321559 Steel "SHOTGUN" TRIM ARRANGEMENT SIZE A B C 2" 101, 8 3/4" 2 1/4" 2 1/2" 11" 9 1/4" 2 1/4" 65mm 11" 9 1/4" 2 1/4" 3" 12" 9 1/2" 2 1/2" 4" 13 1/2" 101, 3 1/4" 6" 14 1/4" 10 3/4" 4" 150mm 14 1/4" 10 3/4" 4" 8" 15 1/4" 12 1/4" 5" ` FRONT VIEW TOP VIEW ITEM DESCRIPTION 2" (DIN 50) 2 1/2" (76mm Pipe O.D.) 3" (DIN 80) 4" (DIN 100) 6" (16515 Pipe O.D.) 8" (DIN 200) QTY. 1 RCV 321526 321533 321533-D 321539 321547 321557 321557 321576 1 2 Angle Valve 311614 (1") 311615 (1 1/4") 311615 (1 1/4") 311615 (1 1/4") 311617 (2") 311617 (2") 311617 (2") 311617 (2") 1 3 Close Nipple 3210500 (1") 310600 (1 1/4") 310600 (1 1/4") 310600 (1 1/4") 310800 (T) 310800 (T) 310800 (T) 310800 (T) 1 4 1/4" Water Gauge 300119 300119 300119 300119 300119 300119 300119 300119 2 5 1/4" 3-Way Valve 311683 311683 311683 311683 311683 311683 311683 311683 2 6 1/4" Plug 311001 311001 311001 311001 311001 311001 311001 311001 2 7 1/4" Nipple 311101 (1 1/2") 311102 (T) 311102 (T) 311102 (T) 310103 (21/2") 310103 (21/2') 310103 (21/2') 310103 (21/2") 1 8 1/4" x 5 1/2" Nipple 310109 310109 310109 310109 310109 310109 310109 310109 1 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 GL IBE 989-846-4583 FAX 989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com FEBRUARY 2015 PRINTED U.S.A. BULLETIN RCV, REV. #4 WILSON & COUSINS 4390 PALETTA COURT, UNIT M, BULINGTON, ONTARIO, CANADA 1-71- 5132 INTERIOR FIRE PROTECTION 1 800 270 67921 FAX: (905) 637 8655 I info@wilsonandcousins.com [ IE23 ] 2.5" Standard Angle Hose Valve. 2.5" Grooved Inlet x 2.5" Male Hose Thread Outlet. Dimensions: Heavy Duty 2-1/2" (65 mm) angle hose, 300 lb (2070 KPa) pressure tested approved valve. Lightweight cast brass body, Forgeline Bonnett and Seat Assembly. UL/ULC listed and FM Approved. Specify regional hose thread for outlet. FINISH: Cast Brass OPTIONS: Polish Brass, Cast Chrome, Polish Chrome HOSE THREADS AVAILABLE: CSA, BCT, WCT,QST, NSST, NPSH, NST, Louisville, Cleveland, Chicago, Pittsburgh, New Cincinnati, New York Corp., New York Fire Department, Richmond, Raleigh OTHER HOSE THREADS: PLEASE CONTACT FACTORY A=5" (125mm) B=3 3/16" (79mm) C=11.8" (OPEN) (300mm) C=10.5" (CLOSED) (267mm) Weight: 9lbs (4.09 Kg) Working Pressure: 3001b (2070 Kpa) 1/1 Bulletin 135 Rev. M c R Model F1 Rel ble Residential Sprinklers for Design Density of .05 gpmfft2 Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmfft2 Types: 1. F1 Res 30 Pendent 2. F1 Res 30 Recessed Pendent/F2 3. F1 Res 30 Recessed Pendent/FP 4. F1 Res 49 Pendent 5. F1 Res 49 Recessed Pendent/F1 6. F1 Res 49 Recessed Pendent/FP 7. F1 Res 58 Pendent 8. F1 Res 58 Recessed Pendent/F1 9. F1 Res 58 Recessed Pendent/FP 10. F1 Res 76 Pendent 11. F1 Res 76 Recessed Pendent/F1 12. F1 Res 76 Recessed Pendent/FP 13. F1 Res 30 CCP Pendent 14. F1 Res 49 CCP Pendent 15. F1 Res 58 CCP Pendent 16. F1 Res 76 CCP Pendent 17. F1 Res 44 HSW 18. F1 Res 44 Recessed HSW/F2 19. F1 Res 58 HSW 20. F1 Res 58 HSWX 21. KRes58 HSWX 22. F1 Res 58 HSW Recessed HSW/F2 23. F1 Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) F1 Res 30, 49, 58 & 76 Recessed Pendent / F1 F1 Res 30, 49, 58 & 76 CCP Pendent Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model F1 Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model F1 Res 44 SWC Sprinklers Product Description Model F1 Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass -bulb and low profile decorative design. The F1 Res F1 Res 30, 49, 58 & 76 Recessed Pendent / FP F1 Res 58 HSWX F1 Res 44 & 58 F1 Res 44 SWC Recessed HSW/F2 Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass -bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow F1 Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat -sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass -bulb • Sprinkler Frame : Brass Casting • Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: 1/2" NPT (R'/2) • K-Factor: 3.0 (43.2) (Actual) - F1 Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - F1 Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - F1 Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - F1 Res 76 Pendent Sprinkler 4.4 (63) (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.05 gpm/ft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 13 2013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, F1 or F2, Data: the only recessed escutcheons to be used with Model F1 Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model F1 Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. Type Adjustment "A" Face of fitting to ceiling B Deflector Distance below bottom of beam Inch (mm) Inch (mm) Inch (mm) Inch (mm) F1 3/4 (19.0) Min. Recessed = 15/e (41.3) 3/3 (9.5) 13/4 (44.4) Max. Recessed =7/a (22.2) 11/3 (28.6) 1 (25.4) F2 /2 (12.7) Min. Recessed = 15/8 (41.3) 3/3 (9.5) 13/4 (44.4) Max. Recessed =11/8 (28.6) 7/e (22.2) 11/4 (31.7) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49, 58 & 76 Recessed Pendent Sprinkler • Model F1 Res 30 Recessed Pendent / F2 • Model F1 Res 30, 49, 58 & 76 Pendent • Mod( Fig. 1 !1 1-1 KeS 4% bt3 & [b Kecessea F'eni lent / F1 F1 escutcheon, 3/4" (19mm) adjustment 2 1/4" HOLE DIA. [57.2—] 1 15/16" DIA. [49.2m 1 1 "" X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER FACE OF FITTING TO WRENCH BOSS. F 1 CEILING DIMENSION., 3/8"-1 1/8" (F1 ESCUTCHEON) 3/8"-7/8" (F2 ESCUTCHEON) ADJUSTMENT 095tltl (3.2mml 2 27/32" DIA. +as�roie (72.2_1 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN R3511) Fig. 2 Thread Size Nominal Orifice Inch mm Max. Pressure si bar Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch mm rF rc rF PC 1/2" NPT 21/64" (8.2) 175 (12) 7g 100 38 3.0 (43.2) 2.25 (57) 155 Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing 155?F/68WC 175rF/79rc Top of Deflector to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Umin) PSI bar GPM Umin PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 8(30,3) 7.0 (0,48) 8(30,3) 7.0 (0,48) Smooth Ceilings 11/4 to 4 (31.7 to 102) using F2 escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 11/4 to 13/4 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 10 (37,8) 11 (0,76) 10 (37,8) 11 (0,76) 16 x 16 (4,9 x 4,9) 16(4,9) 13 (49) 18.8 (1,3) 13 (49) 18.8 (1,3) 31.7 to 44.4 using F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: F1 Res 49 Pendent and Recessed Pendent (SIN R3516) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Tem . atin Ambient Temp. K Length PF PC PF PC psi bar Factor Inch mm 1/2" NPT '/,s" (11) 175 (12) 155 68 100 38 4.9 (70.6) 2.25 (57) R'/2 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155PC 175wF179WC Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) GPM Vmin PSI bar GPM Vmin PSI(bar)Inch In (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) Smooth Ceilings 1'/4 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) 1 to 4 (25.4 to 102) using F1 escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 17 (64,3) 12 (0,83) 17 (64,3) 12 (0,83) beams 1'/4 to 13/4 (31.7 to 44.4) using F2 escutcheon, 1 20 x 20 (6,1 x 6,1) 20(6,1) 20 (75,7) 16.7 (1,14) 20 (75,7) 16,7 (1,14) to 13/4 (25.4 to 44.4) using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155?F/1 C 175PF/79PC Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) In (mm) Ft (m) GPM in) PSI bar GPM Vmin PSI(bar)Inch 12 x 12 (3,6 x 3,6) 12(3,6) 15 (57) 9.4 (0,65) 15 (57) 9.4 (0,65) Smooth Ceilings 4 to 8 (100 to 203) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (60,5) 10.6 (0,73) 16 (60,5) 10.6 (0,73) 4 to 8 (100 to 203) using F1 escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,3) 12.0 (0,83) 17 (64,3) 12.0 (0,83) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72) 15.0 (1,0) 19 (72) 15.0 0 ,0) 4'/4 to 8 (108 to 203) using F2 escutcheon, 4 to 8 (100 to 203) 20 x 20 (6,1 x 6,1) 20(6,1) 22 (83,2) 20.2 (1,4) 22 (83,2) 20.2 (1,4) using F1 escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Tem . Ratin Ambient Temp.Length K Factor PF PC PF PC psi (bar) Inch (mm) 1/2" NPT 1/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.25 (57) (R'/2) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155PFWC 175"F/79PC to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) n Inch (mm) Ft (m) GPM in) PSI bar GPM Vmin PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) Smooth Ceilings 1'/4 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) 1 to 4 (25.4 to 102) using F1 escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) 19 (72) 10.8 (0,75) 1'/4 to 13/4 (31.7 to 44.4) using F2 escutcheon, 1 to 13/4 (25.4 to 20 x 20 (6,1 x 6,1) 20(6,1) 22 (83,3) 14.4 (1,0) 22 (83,3) 14.4 0,0) 44.4) using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 3. Technical Data: F1 Res 76 Pendent and Recessed Pendent (SIN R7618) Thread Nominal Orifice Max. Sprinkler Max. K Sprinkler Size Inch (mm) Pressure Temp. RatingAmbient Tem Factor Length PF PC PF PC psi bar Inch mm 3/4" NPT "/32" (13.5) 175 (12) 155 68 100 38 7.6 (109) 2.25 (57) R3/4 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing 155PFWC 175PF/79PC Top of Deflector to Ceiling Spacing Flow Pressure Flow GPM Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI bar L/min PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) Smooth Ceilings 41/4 to 8 (108 to 203) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) 4 to 8 (100 to 203) using F1 escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) beams 41/4 to 8 (108 to 203) us- ing F2 escutcheon, 4 to 8 (100 20 x 20 (6,1 x 6,1) 20(6,1) 23 (87,1) 9.2 (0,63) 23 (87,1) 9.2 (0,63) to 203) using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D • Model F1 Res 30, 49, 58 & 76 CCP Pendent* Not listed for corrosion resistance. 2 518" [66.7mm] DIA. 2 5116" DIA. HOLE IN CEILING [58.7mm] CUP ----b—" 1'k1/2" REDUCER CUP CEILING 1 114" [31.5mm] --�.f MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION COVER ADJUSTMENT HEIGHT 3 5116" DIA. 135FC04E [84.1 mm] F1 RES 30, 49, 58 & 76 CCP PEND. Fig. 3 Note: The F1 Res 76 will use a 1 " x %" reducer. CCP Cover Plate Data: Deflector Distance below bottom Cover Adjustment CCP Height of beam Inch (mm) Inch (mm) Inch (mm) 1/2 (12.7) 15/16 (24) 1/2 (13) - 1 (25.4) 5/16 (7.9) 3/4 (19) 1/2 (13) - 1 (25.4) • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / FP FP push-on/thread-off escutcheon 2 518" DIA. [66.7mm] HOLE IN CEILING 2 5116" DIA. [58.7mm] CUP r— 1" X 112 REDUCER CEILING L 7 7/2" [38.7mm] MAX. d� FACE OF FITTING TO FACE OF CEILING D/MENSION 1/2- [13mm] MAX. F A„ $' FP ADJUSTMENT 1 I F1 RES 49 PENDENT/FP Fig. 4 FP Escutcheon Data: ..B,. FP Position "A" Deflector Distance below bottom Inch (mm) of beam Inch (mm) 1/2 (12.7) Max. Recessed 7h6 (11) Min. Recessed 15/15 (24) 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Tern. Ratin Ambient Temp.Length Factor Inch mm psi bar WF WC PF PC Inch mm' 1/2" NPT R1/z 21/64" (8.2) 175 (12) 135 57 100 38 3.0 (43.2) 2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. 155?F/6WC Rating Top of Deflector to Ceiling Inch (mm) Minimum Spacing (m) Flow GPM Umin Pressure PSI(bar)Ft 8(30,3) 7.0 (0,48) Smooth Ceilings'/z to 1 (13 to 25.4) using CCP. /z to 1 (13 to 25.4) using FP escutcheon. 12 x 12 (3,6 x 3,6) 12(3,6) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 11 (37,8) 13.4 (0,92) beams Yz to 1 (13 to 25.4) using CCP. /z to 1 (13 to 25.4) using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Nominal CCP Max. Thread Orifice Max. Assembly Ambient K Sprinkler Size Inch Pressure Temp. Temp. Factor Length (mm) psi (bar) RatingInch (mm) ?F WC rF PC '/z" NPT (RYz) 7/16" (11) 175 (12) 135 57 100 38 4.9 (70.6) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155?F/68eC) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) (m) GPM Umin PSI(bar)Ft 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) Smooth Ceilings Yz to 1 (13 to 25.4) using 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) CCP. '/z to 1 (13 to 25.4) using FP escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 14 (53) 8.2 (0,56) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams'/z to 1 (13 to 25.4) using 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 18 (68,1) 13.5 (0,93) CCP. '/z to 1 (13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6,1) 20(6,1) 20 (75,7) 16.7 (1,14) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. Ratin Ambient Temp. Factor Length WF ?C PF pC Inch (mm) psi (bar) Inch (mm) Yz" NPT (R'/z) /z" (13) 175 (12) 135 57 100 38 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing 155WF/68?C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Umin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 16 (61) 7.6 (0,53) Smooth Ceilings'/z to 1 (13 to 25.4) using CCP. '/z to 1 (13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams'/z to 1 (13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) 1/2 to 1 (13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6,1) 20(6,1) 22 (83,3) 14.4 (1,0) For Ceiling types refer to NFPA 13, 13R or 13D 5. Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. Rating Ambient Temp. Factor Length PF PC PF PC Inch (mm) psi (bar) Inch (mm) 3/4" NPT (R /4) 17/32" (13.5) 175 (12) 135 57 100 150 38 66 7.6(109) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing 155PF/68PC Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) (m) GPM Umin PSI(bar)Ft Smooth Ceilings'/2 to 1 (13 to 25.4) using CCP. 1/2 to 1 (13 to 25.4) using FP escutcheon. 12 x 12 (3,6 x 3,6) 12(3,6) 21 (79,5) 7.6 (0,53) 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 21 (79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1 (13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 22 (83,3) 8.4 (0,58) 1/2 to 1 (13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6,1) 20(6,1) 25 (94,6) 10.8 (0,74) For Ceiling types refer to NFPA 13, 13R or 13D FACE OF FITTING TO WALL DIMENSION 1 1/4" MIN. [31.8mm] 2 1/4" HOLE DIA_ 118 A [57.2mm] CEILING TO [3.2mm] DEFLECTOR I" X 1/2'" REDUCER i �1 DIMENSION 1 15/16" DIA. /inn i — — — [49.2mm] n nni 2 27/32" DIA. nm [72.2mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER �1 WRENCH BOSS. 1/2"" [73mm] 35Fcos—a ADJUSTMENT F1 RES 58 & 44 HSW/F2 Fig. 5 Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 Nominal Max. Sprinkler Max. Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Size Inch (mm) psi (bar) Tem Factor Inch (mm) PF PC PF PC 1/2" NPT 3/3„ (10) 175 (12) 155 68 100 38 4.4(63) 2.45 (62) (R/2) 1 175 79 150 66 F2 escutcheon, 1/2" (13mm) adjustment Escutcheon, F2, Data: Adjustment Face of sitting Type Inch (mm) to ll Inch (mm) F2 112 (1 3) 3/16 — 11/16 (4.7 - 17.4) A Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. 155PF/68rC Rating Intermediate 175WF/79PC Temp. Rating Top of Deflector to Ceiling (mm) 4 to 6 (100 to 152); 1/2 (13) recessed using F2 escutcheon Minimum Spacing Ft (m) 8(2,4) Flow GPM Umin Pressure PSI bar Flow GPM in) Pressure PSI(bar)Inch 12 x 12 (3,6 x 3,6) 12(3,6) 12 (45,4) 7.5 (0,52) 12 (45,4) 7.5 (0,52) 14 x 14 (4,3 x 4,3) 14(4,3) 14 (53,0) 10.2 (0,71) 14 (53,0) 10.2 (0,71) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (60,6) 13.3 (0,92) 16 (60,6) 13.3 (0,92) 16 x 18 (4,9 x 5,5) 16(4,9) 18 (68,1) 16.8 (1,16) 18 (68,1) 16.8 (1,16) 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72,0) 18.7 (1,29) 19 (72,0) 18.7 (1,29) 16 x 20 (4,9 x 6,1) 16(4,9) 23 (87,1) 27.4 (1,89) 23 (87,1) 27.4 (1,89) 12 x 12 (3,6 x 3,6) 12(3,6) 14 (53,0) 10.2 (0,71) 14 (53,0) 10.2 (0,71) 6 to 12 (152 to 305); 1/2 (13) recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4,3) 16 (60,6) 13.3 (0,92) 16 (60,6) 13.3 (0,92) 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,4) 15.0 (1,04) 17 (64,4) 15.0 (1,04) 16 x 18 (4,9 x 5,5) 16(4,9) 20 (75,7) 20.7 (1,43) 20 (75,7) 20.7 (1,43) 16 x 20 (4,9 x 6,1) 16(4,9) 23 (87,1) 27.4 (1,89) 23 (87,1) 27.4 (1,89) For Ceiling types refer to NFPA 13, 13R or 13D Nominal Max.. Sprinkler x. Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Size Inch psi (bar) Temp. Factor Inch WF WC WF I PC (mm) (mm) 1/2" NPT 112" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.45 (62) (R1/2) 175 79 150 66 Escutcheon, F2, Data: Adjustment Facef Fitting Type Inch (mm) o all Inch (mm) F2 112 (13) 3/16 - 11/16 (4.7 - 17.4) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing 155PF/68PC 175WF/79rC Ceiling Spacing Ft x Ft (m x m) Ft (m) Flow Pressure Flow Pressure Inch (mm) Ft (m) GPM Umi 16 (60,6) 18 (68,2) 21 (79,5) 25 (94,7) 29 (109,8) 22 (83,3) 22 (83,3) 26 (98,4) 31 (117,4) 12 x 12 (3,6 x 3,6) 12(3,6) 14 x 14 (4,3 x 4,3) 14(4,3) 16 x 16 (4,9 x 4,9) 16(4,9) 16 x 18 (4,9 x 5,5) 16(4,9) 16 x 20 (4,9 x 6,1) 16(4,9) 12 x 12 (3,6 x 3,6) 12(3,6) 14 x 14 (4,3 x 4,3) 14(4,3) 16 x 16 (4,9 x 4,9) 16(4,9) 16 x 18 (4,9 x 5,5) 16(4,9) Ceiling types refer to NFPA 13, 13R or 13D PSI kwar, 7.6 (0,53) 9.7 (0,69) 13.2 (0,91) 18.6 (1,28) 25.0 (1,73) 14.4 (1,0) 14.4 (1,0) 20.1 (1,39) 28.6 (1,97) GPM &LJ1111r 16 (60,6) 18 (68,2) 21 (79,5) 25 (94,7) 29 (109,8) 22 (83,3) 22 (83,3) 26 (98,4) 31 (117,4) PSI bar 7.6 (0,53) 9.7 (0,69) 13.2 (0,91) 18.6 (1,28) 25.0 (1,73) 14.4 (1,0) 14.4 (1,0) 20.1 (1,39) 28.6 (1,97) 4 to 6 (100 to 152); 1/2 (13) recessed using F2 escutcheon 6 to 12 (152 to 305); 1/2 (13) recessed using F2 escutcheon 8(2,4) 7. • Model F1 Res 44 SWC* " Not listed for corrosion resistance. 4" to 12" [107. 60mm To 1 1/4" [31.75mm] Maximum 304.80mm] Face Of Fitting To Wall Dimension PUSH ON COVER, THEN TURN TO ADJUST UNTIL TIGHT AGAINST WALL. 1" X 1/2" Reducer id `� Recommended it iimi Wall Hole 2 5/8' 2 5/76" [58.74mm]�--x',�--- - - --F- (66.68mm] Dia. iiiiil 3 5/76" 1 [84.74mm] Dia TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER _ 1 21/32" WRENCH BOSS. [42.07mm] 135F007 1/2" [12.70mm] Adjustment F1 RES 44 SWC Fig. 6 TPr_hnir_al Data- F1 Rpc 44 SWC (SIN R35311 Nominal Max. Cover Max. Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size Inch (mm) psi (bar) Ratin Tem Factor Inch (mm) pFL57 pF pC 112" NPT (R/2) 3/8" (10) 175 (12) 135100 38 4.4 (63) 2.45 (62) Ordinary Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (155?F/68r'C) Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Umin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49,2) 8.7 (0,60) 4 to 6 (100 to 152); 14 x 14 (4,3 x 4,3) 14(4,3) 14 (53,0) 10.2 (0,71) 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,3) 15.0 (1,1) 1/2 (13) recessed using F2 escutcheon 16 x 18 (4,9 x 5,5) 16(4,9) 19 (71,8) 18.7 (1,13) 8(2,4) 16 x 20 (4,9 x 6,1) 16(4,9) 23 (87,1) 27.4 (1,89) 12 x 12 (3,6 x 3,6) 12(3,6) 14 (52,9) 10.2 (0,71) 6 to 12 (152 to 305); 1/2 (13) recessed 14 x 14 (4,3 x 4,3) 14(4,3) 15 (56,7) 11.7 (0,81) 16 x 16 (4,9 x 4,9) 16(4,9) 18 (68,1) 16.8 (1,16) using F2 escutcheon 16 x 18 (4,9 x 5,5) 16(4,9) 20 (75,6) 20.7 (1,43) For Ceiling types refer to NFPA 13, 13R or 13D 91 Technical Data: F1 Res 58 HSWX (SIN RA3533) Nominal Max. Sprinkler Max. Sprinkler Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Identification Size Inch (mm) psi (bar) em . Factor Inch (mm) Number (SIN) pF PC PF Bulb 1/2NPT 1/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.45 (62) RA3533 (R1/2) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (155?F/68?C) (175PF/79?C) Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Umin) PSI bar GPM Umin) PSI bar 4 to 6 (100 to 152); 18 x 20 (5,5 x 6,1) 18(5,5) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 20 x 20 (6,1 x 6,1) 20(6,1) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 6,7) 16(4,9) 33 (125) 32.4 (2,23) 33 (125) 32.4 (2,23) 1/2 (13) recessed using F2 escutcheon 16 x 24 (4,9 x 7,3) 16(4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 8(2,4) 14 x 26 (4,3 x 7,9) 14(4,3) 42 (160) 52.4 (3,75) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18(5,5) 35 (133) 36.4 (2,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); 1/2 (13) recessed 16 x 22 (4,9 x 6,7) 16(4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42 (160) 52.4 (3,6) 42 (160) 52.4 (3,6) using F2 escutcheon 14 x 26 (4,3 x 7,9) 14(4,3) 46 (174) 62.9 (4,34) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D FACE OF FITTING TO WALL DIMENSION 2 114" HOLE OIA. [57.2mm] 1 ' X 112 " REDUCER � nni 1 15/16" DIA.� / inn [49.2mm] u i n inn i I nin � L_om i TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. 135FG08 1 11116" MIN. [31.8mm] (3.2mm] CEILING TO DEFLECTOR DIMENSION _ I 2 27132" DIA. J [72.2mm] �I 112" [13mm] ADJUSTMENT F1 RES 58 HSWX Fig. 7 • Model F1 Res 58 HSWX (Bulb) • Model KRes58 HSWX (Link) N Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Factor Length Identification Inch (mm) psi (bar) WF I PC Inch (mm) 2.45 (62) Number (SIN) RA3593 Link '/z NPT (R'/2) 1/2" (13) 175 (12) 100 38 5.8 (83.5) Ordinary Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (165?Fl1VC Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM Umin PSI (bar) 4 to 6 (100 to 152); 18 x 20 (5,5 x 6,1) 18(5,5) 29 (109) 25 (1,72) 20 x 20 (6,1 x 6,1) 20(6,1) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 7,3) 16(4,9) 33 (125) 32.4 (2,23) 1/2 (13) recessed using F2 escutcheon 16 x 24 (4,9 x 7,3) 16(4,9) 38 (144) 42.9 (2,96) 8(2,4) 14 x 26 (4,3 x 7,9) 14(4,3) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18(5,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); 1/2 (13) Recessed 16 x 22 (4,9 x 6,7) 16(4,9) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42 (160) 52.4 (3,6) using F2 escutcheon 14 x 26 (4,3 x 7,9) 14(4,3) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model F1 Res 30, 49, F1 Res 58, F1 Res 76 and F1 Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Model F1 Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector - to -ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome - plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model F1 Res 30, 49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Model F1 Res 49 & 58 Recessed Pendent/F1, Model F1 Res 30, 49 & 58 Recessed Pendent/ F2, Model F1 Res 30, 49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector -to -ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top -loaded extruded 'DuPont Registered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [1550F (68°C)] [175°F (79°C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Special finish— spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjustment (Model F2)] [with 3/4" adjustment (Model F1)] [of push -on and thread off design with'/2" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model F1 Res 30, 49 & 58 Recessed Pendent/F1 ] [Model F1 Res 30, 49 & 58 Recessed Pendent/F21 [Model F1 Res 30, 49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model F1 Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a'/2" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model F1 Res 44, F1 Res 58 Horizontal Sidewall, F1 Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel - "DuPont Registered Trademark leville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The F1 Res 58 HSW is also available with low lead frame. F1 Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and F1 Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Special finish— specify]. Residential horizontal sidewall sprinklers shall be Reliable Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model F1 Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 44 horizontal side - wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with'/2" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44/F2, SIN R3531 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Spe- cial finish— specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). 11. Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjust- ment (Model F2)] [with 3/4" adjustment (Model F1)] [of push -on and thread off design with adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/ 1`1 ] [Model F1 Res 76 Recessed Pendent/1`21 [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having "DuPont Registered Trademark a temperature rating of 1550F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a'/2" cover plate adjustment. Cover plate tem- perature rating shall be 1350F (57C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes F1, F2, FP Sprinkler Escutcheons Cover Plates Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester (2) Coated Special Application Finishes Sprinkler F1, F2, FP Escutcheons Electroless Nickel PTFE(Teflon11)(2) Electroless Nickel PTFE (Teflon®) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull (') Other finishes and colors are available on special order. Consult factory for details. (2) cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. ® Recycled ® (800) 431-1588 Sales Offices Paper Relleiabi (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/15 P/N 9999970235 Bulletin 014 Rev. P Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & Fi FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. 1. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS SchadenverhOtung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Model F1 FR Series Quick Response Glass Bulb Sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 �J Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP W__ A* XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1 FR series sprinklers are quick -response automatic sprin- klers with a glass bulb thermal element. IV Model F1 FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1 FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR Series sprinklers to apply water to a fire faster than standard -response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Cj c 0 Dj Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1 FR Series sprinklers provide a wide range of op- tions where quick -response, glass bulb sprinklers are used: • Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) • Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1 FR series sprinkler configurations. Model F1 FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1 FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.Omm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1 FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1 FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1 FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1 FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1 FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1 FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers have a factory -installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1 FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1 FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. a Technical Data: Sensitivity: Quick -response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm Pendent 2.25 57 D or W2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 F1FR28 2.8 40 38 10 Upright 2.25 57 D or W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 D or W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D or W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Upright 2.25 57 D or W2 RA1423 cULus 1,2 F1 FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D or W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1 FRXLH Pendent 2.25 57 D or W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 D or W2 RA1423 cULus 1,2 Pendent 2.25 57 D or W2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 F1 FR56 5.6 80 112 15 Upright 2.25 57 D or W2 RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional (Pendent or Upright)" 2.25 57 D or W2 RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 D or W2 RA1415 cULus, ULH 1 Fl FR56LL 5.6 80 112 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 RC1 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 D or W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 D or W2 RA1485 cULus, FM, LPCB 1,2,3,9 (') cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (1) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (5) VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (1) Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (') cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1 FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (1) cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (1) The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100T (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150T (65°C) Max. Ambient Temp. High Temp. Classification 225T (1OTC) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286T (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus Upright cULus Pendent VdS F1FR40 Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus Upright cULus Pendent -- cULus, ULH -- FlFR42LL Recessed Pendent -- cULus, ULH -- Pendent cULus FIFRXLH Recessed Pendent cULus Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- Concealed Pendent* cULus cULus,VdS,EC I cULus F1FR56 Upright cULus, FM, LPCB, VdS, EC "Conventional Pendent or Upright)" LPCB, VdS, EC Pendent -- cULus, ULH -- Fi FR56LL Recessed Pendent -- cULus, ULH -- Concealed Pendent` -- cULus, ULH -- Horizontal Sidewall cULus, FM FlFR56 Recessed Horizontal Sidewall cULus, FM -- FlFR56 Vertical Sidewall (Pen- dent or Upright) cULus, FM, LPCB * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 1650F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model F1 Model F2 Model FP Deflector/ Model Orientation (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 FlFR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 FIFR42XLH Recessed Pendent cULus cULus cULus RA1413 FlFR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS, EC FlFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 FlFR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS --�\\ F7 ESCUTCHEONS Uzz 3/4'[19mm] ADJUSTMENT E2 ESCUTCHEON 1/2'T 12.7mm] ADJUSTMENT 2 114" HOLE DIA. [57.2mmJ 1 15116" DIA [49.2mm] l S i i -1 II II L J� 2 27132" DIA. [72.2mm] 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 'T25.4mm] AT MINIMUM RECESS = 318'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'[19mm] 7-7-77-7-77 AT MINIMUM RECESS = 3/8'[9.5mm F1 ESCUTCHEON i/s" AT MAXIMUM RECESS = 7/8'T22.2mm] [3.2mmJ AT MINIMUM RECESS = 1-5/8'T41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'T28.6mm] AT MINIMUM RECESS = 1-5/8'T41.3mm] Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR421-L, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1 " X 1/2"' REDUCER -----I----- 2 5/8" DIA. [66.7mm] HOLE IN CEILING , I 2 5/16" DIA. [58.7mm] CUP L J CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION - - AT MAXIMUM RECESS = 1-1/2 "T38mm] AT MINIMUM RECESS = 1 'T25.4mm] AT MAXIMUM RECESS = 9/16'T14.3mm] %2'T 12.7mm] AT MINIMUM RECESS = 1 'T25.4mm] ADJUSTMENT Al� 3 1/4" DIA. [82.6mm] Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 'T25.4mm] AT MINIMUM RECESS = 3/8'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'T 19mm] AT MINIMUM RECESS = 3/8'T9.5mm] 2 1/4" HOLE DIA. [57.2mm] 1 " X 1/2" REDUCER 1 15/16" DIA. [49.2mm] Ili wn � TURN COLLAR UNTIL —` TIGHT AGAINST SPRINKLER WRENCH BOSS. F1 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8 [ 34 9 J m m AT MINIMUM RECESS = 2-1/16'T52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] 2 27/32" DIA. [72.2mm] F7 ESCUTCHEON 3/4'T 19mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T 12.7mm] ADJUSTMENT 4"-12"' (1) [101.6mm-304.8mm] CEILING TO DEFLECTOR oliFoom RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon I" x 112" REDUCING TEE OR ELBOW 2 5116" DIA — CUP CEILING 2 518 " DIA. HOLE IN CEILING 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING """' DIMENSION I 112 " MAX. COVER ADJUSTMENT j COVER PLATE / ASSEMBLY 3 5/ 16 " DIA SPRINKLER 15/16" CONCEALED. 1 /2" ADJUSTMENT 017FG01A Fig. 4 Model F1 FR56/1`1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate N X TEE 112" REDUCING OR ELBOW _ 2 5116" CEILING 5116 " MAX. --I COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER - 2 518" DIA. HOLE IN CEILING CONCEALED, 5/16" ADJUSTMENT 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 017Fco2A 514" Fig. 5 - Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.Omm) adjustment - Model CCP cover plate Maintenance The Model F1 FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon I Cover plateM Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4>(5"6 White Painted S ecial Application Finishes Sprinkler Escutcheon Cover plateM Electroless Nickel PTFE(7) Electroless Nickel PTFE B right Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6) Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (') Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed 'corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) _PCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. (') cULus listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135'F (57'C)][155'F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.Omm) adjustment] 9. Cover plate Temperature Rating: [135'F (57°C) for use with Ordinary Temperature sprinklers][165'F (74'C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. ® Recycled (800) 431-1588 Sales Offices Paper Reliabld (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03 /17 P/N 9999970300 Bulletin 013 Rev. N R I a ®R eim ble Models F1 Series Standard Response Sprinklers VA Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pendent/F1 /F2/FP Horizontal Sidewall Model F142, F1 XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1/F2/FP Approval Organizations 1. Underwriters Laboratories Inc. and certified for Canada (cULus) 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS SchadenverhOtung GmbH 5. EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1325) 0786-CPD-40254 (RA1375) UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. Upright Pendent Conventional q *nr 10 Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 f Recessed Recessed XLH Upright Horizontal Sidewall Pendent/FP XLH Pendent Pendent F1/F2 XLH Recessed Pendent FP The F156, F142, F1 XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pin tle (XLH Only) Deflector Load Screw Washer Bulb Frome Cup 07JFG04 Model F142, F1XLH Upright Technical data: Thread n. Temperature Models Nominal K-Factor Response Size Working Worlking Rating Finish Pressure Pressure F156 5.6 (80 Metric) /z" NPT See See F1 FiXLH 4.2 (60 Metric) Standard (R'h) 175 PSIM 7 PSI "Temperature " Finish Table" Ratings" Table F128 2.8 (40 Metric) Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 DZR Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass QM Brass or CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 0) Model F156 upright, pendent, and recessed pendent sprinklers (SIN RA1325 and RA1314) are cULus Listed for 250 psi (17 bar). 2. Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Approval Organization Sprinkler Identification Number SIN US Metric Uri light Pendent Standard -U ri ht SSU and Dendent Deflectors Marked to Indicate Position 1/2" 15mm rn 1/2" NPT R1/2 5.6 80 2.25" 57mm 1 2 3 4 5 RA1325(2)(3)(5)(6) RA 1314(2)(3)(5)(6) '/16" 10mm 1/2" NPT R1/2 4.2 60 2.25" 57mm 1 RA1323(2)(6) RA1313(6) 3/8" 10mm 1/2" NPT R1/2 2.8 40 2.25" 57mm 1 RA1321(2)(s) RA1311(6) Conventional -Install in Upright or Pendent Position 15mm (1) 1/," NPT R1/25.6 1 80 1 57mm 1 3 4 5 1 RA1375(5) (1) Refer to Bulletin 024 for Special Response Sprinklers (F1 S5-56) (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) Polyester coated FM Approved sprinkler. (4) ----- Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. (g> Electroless Nickel PTFE Plated - UL listed Corrosion Resistant Upright Pendent Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers') Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Conventional Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Sprinkler Identification Number SIN US Metric 1/2" 15mm 1/2" NPT R1/z 5.6 80 2.25" 57mm RA1314(2) '/g" 10mm 1/2" NPT R1/2 4.2 60 2.25" 57mm RA1313(2) 3/g 10mm 1/2" NPT R1/2 2.8 40 2.25" 57mm RA1311(2) (1) Refer to escutcheon data table for approvals & dimensions (2) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant 2 1/4- HD DlA �5�.2mmi ' (as zmmj rL c—i, 1 X1/1"REDUCER UNm i s a WRENCH BOSS \ / FACE OF FIRING CE OF CEILING DIMENSION F1 rsrUirHFnN II Ir 1 II fff i 1 AT MAXIM MRECESS = (25.4mmJ �j/TT 4_0 L J AT MINIMUM R£C£65 3/8'T9.Smm] F2 ESCUTCHEON FI FS!`1?rH (19mm] L'( AT MAX/MUM RECESS = 3/4 (19mm] ADJUSTMENT � A AT MINIMUM RECESS 3/8r9.5mm] 1/2 [12. ]mm] ADJUSTMENT CMUTCHEON TIIS A UM RECESS = 111[22.2mm] (J11mm] AT MINIMUM RECESS 1-5/B [41.3mm] F2 ESCUTCHEON AT MA%IMUM RECESS 1-1/8[28.6mm] AT MINIMUM RECESS = I-5/B[41.3mm] 2 27/32- DR. []2.2mm] O13FG01C RECESSED PENDENT W/F1 OR F2 ESCUTCHEON -SPRINKLER NOT FM APPROVED WITH FI ESCUTCHEON Model F156, F142, F1XLH & F128 F1 or F2 r—_ 1" X 1/2" REDUCER 2 5HOL D/A. CEILINf66.7G m] HOLE IN CEILING \ / 2 5/16" DIA. (58.7mm] CUP L L CEILING FACE OF FITTING Dada TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1-1/2[38mm] AT MINIMUM RECESS = 1 [25.4mm] I AT MAXIMUM RECESS = 9/16 [14.3mmj [50.8mm] AT MINIMUM RECESS = 1 [25.4mm] ADJUSTMENT DIA. 82.6mm] RECESSED PENDENT W/FP ESCUTCHEON D13 o2B -SPRINKLER NOT FM APPROVED WITH FP ESCUTCHEON Model F156, F142, F1XLH & F128 FP 9 Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Installation Data: Vertical Sidewall Nominal Orifice Thread Size Nominal K Factor Sprinkler Height Approval (1) Organizations Sprinkler Identification US Metric Numbers (SIN) 112" (15mm) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 RA13850)(2)(3)c4> (1) LPC Approval is pendent only, 570C through 141 °C ratings. (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (4) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector: HSW F_ FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1'T25.4mm1 AT MINIMUM RECESS = 3/8'[9.5mm) F1 ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 7-3/8'T34.9mm] AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] AT MINIMUM RECESS = 3/8'[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-518'T41.3mm] r 2 1/4" HOLE OIA. 1/8„ AT MINIMUM RECESS = 2-1/16'T52.4mm1 [57.2mm] 1" X 7/2- REDUCER it ii to � % (v 7 15/ 16- DIA.A iiln 4„-12" --- ---- [107.6mm-304.8mm] [49.2mm] 2 27/32" DIA. CEILING TO L_°°JJJ [72.2mm] DEFLECTOR TURN COLLAR UNTIL i1 TIGHT AGAINST SPRINKLER \\y WRENCH BOSS. F7 ESCUTCHEON 3/4'[19mm] ADJUSTMENT F2 ESCUTCHEON 112'T12.7m 1 ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [1O1.6MM — 152.4MM] CEILING TO DEFLECTOR. Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. FM and cULus permits use with F1 or F2 escutcheons for "Light Hazard" only. Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data:Horizontal Sidewall Nominal K Factor Sprinkler Nominal Orifice Thread Size Height US I Metric Approval Organizations Light Hazard Ordinary Hazard Sprinkler Identification Numbers (SIN) 1 1/2" (15mm) I 112" NPT (R1/2) 1 5.6 1 80 1 2.63" (67mm) I 1,2 1 1 1 RA1335(1)(2)(3)(4> McULus Listed corrosion resistant (Polyester coated) sprinkler. (2)cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (3) Polyester coated FM approved sprinkler. (4) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant 4. Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & F128 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdic- tion Installation. Installation Model F156, F142, F1XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench or Model W2 Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model F1, F2, and FP Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1 XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight'/2' NPT (R'h) sprinkler joint can be obtained with a torque of 8 -18 ft-lbs (11- 24 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impair- ment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Nominal K-Factor 4. Temperature Rating 5. Sprinkler Finish 6. Thread Type: [1/2" NPT] [ISO 7-1 R'/z] 7. Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (') (') SIN: RA1335 - cULus and FM permits use with F1 or F2 escutcheons for light hazard only. Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non -operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color wC PF Ordinary 57 135 1000F (38OC) Orange Ordinary 68 155 1000F (380C) Red Intermediate 79 175 1500F (66OC) Yellow Intermediate 93 200 1500F (660C) Green HighM 141 286 2250F (1070C) Blue Extra High0) 182 360 3000F (1490C) Mauve Ultra High (1)(2) 260 500 1 4750E 2460C Black (') Not available for recessed Sprinklers. (2) cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) SIN RA1325 & RA1314 cULus listed for 250 psi (17 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) FinisM'> Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (6)(7)(9) White Painted S ecial ADolication Finishes r rink) Escutcheon Electroless Nickel PTFE3x10) Electroless Nickel PTFE Bright Brass(2) Bright Brass Black Plated Black Plated Black Paint(3)(9) Black Paint Off White(3)(9) Off White Chrome Dull Chrome Dull Lead Plated(3)(4)(8) Wax Cioated(3)(4)(5)(8) Wax Over Lead(3)(4)(5)(8) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. (2)2000F (930C) maximum. (3) UL and ULC listed only. (4)1550F to 2000F (680C to 930C) ratings only. (6)2860F (1410C) sprinklers may be coated for ambient conditions not exceeding 150OF (660C). (6) cULus listed "corrosion resistant' applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1 321 (Upright), RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (7) FM Approved finish as 'Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. (8) FM Approved finish applies only to SIN number RA1335 & RA1385. (0) LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. (10)cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323, RA1313,RA1321, RA1311, RA1385and RA1335 5. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. 97111111 Recycled iabil® (800) 431-1588 Sales Offices NVPaper e () 8-051 Sales Fax (914914) 82929-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/17 P/N 9999970299