Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2022-1476_Manufacturer_Specifications_and_Installation_Instructions_10.26.2022_4.22.09_PM_3187553
ELECTRICAL DATA Power Output - PMAx (W P) Watt Class Sorting-(W) Nominal Power Voltage -VMPP (V) u Nominal Power Current-IMpp(A) to Open Circuit Voltage-Voc(V) Short Circuit Current- Isc (A) Power Density (W/mz) Panel Efficiency (%) Product Code': RECxxxAA Pure 390 395 400 405 0/+5 0/+5 0/+5 0/+5 41.5 41.8 42.1 42.4 9.40 9.45 48.6 48.7 10.22 10.25 211 214 21.1 21.4 9.51 9.56 48.8 48.9 10.28 10.30 216 219 21.6 21.9 410 0/.5 42.7 9.61 49.0 10.35 222 22.2 Power Output - PMAx(WP) 297 301 305 309 312 Nominal Power Voltage-VMPP(V) 39.1 39.4 39.7 40.0 40.2 O No minaIPowerCurrent- IMpp(A) 7.59 7.63 7.68 7- 7.72 7.76 Z Open Circuit Voltage - Voc(V) 45.8 45.9 46.0 46.1 46.2 Short Circuit Current - Isc(A) 8.20 8.24 8.28 8.32 8.36 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m2, temperature 25°C), based on a production spread with a tolerance of PMAx, Voc& I5c 13 %within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m2, temperature 20°C, windspeed 1 m/s).* Where xxx indicates the nominal power class (PMAx) at STC above. MAXIMUM RATINGS WARRANTY Operational temperature: -40...+85°C Standard REC ProTrust Maximum system voltage: 1000V Installed by an REC No Yes Yes Certified Solar Professional Maximum test load (front): +7000 Pa (713 kg/m2)' System Size All ,25 kW 25-500 kW Maximum test load (rear): -4000Pa(407kg/m2)* Product Warranty (yrs) 20 25 25 Max series fuse rating: 25A Power Warranty (yrs) 25 25 25 Max reverse current: 25 A Labor Warranty (yrs) 0 25 10 See installation manual for mounting instructions. Power inYear 1 98% 98% 98% Design load =Test load/1.5(safetyfactor) Annual Degradation 0.25% 0.25% 0.25% Power in Year 25 92% 92% 92% See warranty documents fordetails. Conditions apply Available from: CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC62804 PID IEC61701 Salt Mist IEC 62716 Ammonia Resistance IS011925-2 Ignitability (Class E) IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-freeacc. to ROHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 CIUS C E [Ed�%J take ke wnnrey , 1take-e-way WEEE-compliant I-, tek Lead -Free recydmg"heme TEMPERATURE RATINGS* Nominal Module Operating Temperature: 44°C (±2°C) Temperature coefficient of PMAx: -0.26 %/°C Temperature coefficient of Voc: -0.24 %/°C Temperature coefficient of Isc: 0.04 %/°C *The temperature coefficients stated are linearvalues DELIVERY INFORMATION Panels perpallet: 33 Panels per 40ftGP/high cube container: 792 (24 pallets) Panels per13.6 m truck: 924 (28 pallets) Panels per 53fttruck: 891 (27 pallets) LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: 0 T w Irradiance (W/m2) Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia -Pacific. Power Optirnizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization 0 MO IN m / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solaredge.com solar =@@ Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 INPUT Rated Input DC Powerlll 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 1251zI 83(2) Vdc MPPT Operating Range 8 - 48 8-60 8 - 80 8-60 12.5 -105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 ± 0.1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class 3, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129x153x33.5 /5.lx6xl.3 129x153x29.5 /5.1x6xl.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129x162x59/ 5.1x6.4x2.3 mm /in Weight (including cables) 630 / 1.4 1 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr/ lb Input Connector MC4131 Singl1Cor dual MC4131 Wire Length 0.16 / 0.52 m / ft -Input Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range() -40 - +85 / -40 - +185 °C / 7 Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % (1) Rated power of the module at STC will not exceed the optimizer "Rated Input DC Power". Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals. (5) For ambient temperature above +85°C / +185°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details. Minimum String Length P320, P340, P370, 8 10 18 P400, P401 (Power Optimizers) P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50181 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 6000o) 12750(10) W Parallel Strings of Different Lengths or Orientations I Yes (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string-sizing_na.pdf (7) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W (10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W ® SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. C�US Ro H S All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2020NO2/ENG NAM. Subject to change without notice. Intertek Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE10000H-US / SE1140OH-US r® solarW- Y lDwave 1 _ .. _•► r O solar - .. - ., ��iL1.No�e . oK O O a 0 O Optimized installation with HD -Wave technology / Specifically designed to work with / Extremely small power optimizers / Record -breaking efficiency / Built-in module -level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar=@@ Single Phase Inverter Wit HID -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ - - ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.Sn1 Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VI1j 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(I) - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(') Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG 3/4' minimum / 14-6 AWG 3/4" minimum /14-4 AWG Range DC Input Conduit Size / # of Strings / AWG Range 3/4" minimum / 1-2 strings / 14-6 AWG 3/4" minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / (HxWxD) mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +6003 (-40`F / -40'C option)(') "F / °C Protection Rating NEMA 4X (Inverter with Safety Switch) 0) For other regional settings please contact SolarEdge support m A higher current source may be used; the inverter will limit its input current to the values stated (1) Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf 15) -40 version P/N: SExxxxH-US000NNU4 O SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/201MOVENG NAM. Subject to change without notice. RoHS U-ANCHORTm I U2600-APP Mechanically Attached Solution For Modified Bitumen Roofing Systems Front Back Product Specifications Bolts • 3/8"-16 x 1.5" Bolt* • Material Type: 304 Stainless Steel Plate • Outer Diameter: 5.5" • Fastener Hole Diameter: 0.265" (8 holes) • Fastener Hole Pattern: 4.125" Diameter • Steel Thickness: 0.047" (1.194mm) • Material Type: Galvanized Steel G90 Cover Membrane • Manufacturer: Brand or Non -Brand Specific* • Color: Default White* • Length: 15.75" (1 Ply) • Width: 15.75" (1 Ply) • Thickness: Approx. 130 mils* (1 Ply) Patents • Visit www.anchorp.com/patents Packaging Specifications • Sold Individually OR Full Box Quantity • Individual Weight: Approx. 2 Ibs • Full Box Quantity: 10 units • Box Weight: Approx. 23 Ibs • Box Dimensions: 17" x 17" x 5" • Full Pallet Quantity: 35 boxes • Pallet Dimensions: 48" x 40" x 47" * Specified option is standard. Custom options may be available for additional charge. Lead times may apply depending on roofing manufacturer and product availability. ANCHOR C3 PRODUCTS'" Description The U2600-APP is a lightweight rooftop attachment system consisting of an U-Anchor 2000 Series plate and cover membrane. The U2600-APP includes a factory prepared SIBS cover membrane and separator disk. The U2600-APP provides a fastened, watertight, warranted attachment for APP roofing systems. Advantages • Lightweight: 24 oz. (680 grams). • Fast installation, approximate rate of 12 per man hour. • Installs on any surface from flat to vertical. U-Anchor Attachment The U2600-APP is attached by fastening through the roofing assembly and into the structural decking with 2-8 approved fasteners, as directed by project specific engineering. Depending on the roofing manufacturer's requirements, 1 or 2 plies of membrane may be required. The membrane flashing is torched in place over the primed roof membrane, followed by the separator disk, per the roofing manufacturer's specific methods. Project -specific data is required to determine the correct type of fastener and number needed to secure each U-Anchor. An ANSI/SPRI FX-1 Pull Test is recommended to measure the pull-out resistance of fasteners included in the load path, (for example, substrate -> fasteners -> the U-Anchor -> other components.) Equipment Attachment To securely mount your rooftop equipment to the U-Anchor, after its installed, the connection nut must be tightened to approximately 20-25 ft.-Ibs. Use a calibrated torque wrench during install to ensure appropriate results are achieved. Refer to product documentation for detailed installation and component requirements. Testing Results are based on plate performance only. • Ultimate Load - Shear: 4339 Ibs • Ultimate Load - Tension: 2713 Ibs Tested in accordance with ICC AC467 Individual roof deck assembly tests available upon request as application specific results may vary. Listings • ICC-ES Evaluation Report ESR-4152 Warranty • 20 Year Limited Material Only Warranty. Subject to terms and conditions. All representations herein are premised on proper installation Anchor Products systems are included in and use of approved components. Failure to properly install or use of unapproved components voids all Anchor Products many roofing manufacturers' guarantees! representations. Please contact us for more information. Anchor Products LLC. PO Box 1551 Secured Mounting Solutiorl Colleyville, TX 76034 MADE IN ROOFING MANUFACTURER U. S. A. 888-575-2131 www.anchorp.com info@anchorp.com XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. 6' spanning capability Moderate load capability Clear & black anodized finish Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. 8' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12'spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Buildina Heiaht of 30 ft. Visit IronRidae.com for detailed span tables and certifications. 100 120 None 140 XR10 160 100 120 10-20 140 160 100 30 160 40 100 160 50-70 160 80-90 160 XR100 XR1 r, 0 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.13 // I RON RI DGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Compatible with Flat & Pitched Roofs Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. 11" J � IUMMIEWADW .. I I , 1 . . if, 101 .0 8 1. Nkiz W* Corrosion -Resistant Materials Abof 3i A n -, XR Rails O XR10 Rail i A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Clamps & Grounding O — UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Attachments O FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources Stopper Sleeves _L Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L-Feet XR1000 Rail Bonded Splices A heavyweight mounting All rails use internal splices rail for commercial projects. for seamless connections. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Drop -in design for rapid rail Bond and attach XR Rails attachment. to certified attachments. Secure rail connections Slot for vertical adjusting Clear & black anod. finish esign Assistant o from rough layout to fully E:Jngineered system. For free. o to IronRidge.com/design • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training 0%w Earn free continuing education credits, POP while learning more about our systems. Go to IronRidge.com/training © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 f&,� I RON RI DGE UFO Family of Components Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family —Flush Mount, Tilt Mount and Ground Mount —are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. Stopper Sleeve �ii�d�atee�st into Bonded Splice Grounding Lug f�wg amMEL Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. Bonded Attachments dffufi the System Diagram s�----------------u��---------- --- -- ------------------m----- - - - - -- --- -- --------------- ---mow-- -------- --- -- O UFO C Stopper Sleeve • Grounding Lug m Bonded Splice --L Ground Wire Q 6VWe* Eyg3hasd krrnFhdgen3o6+aasrrdbrainat3rt@rltienow&blo the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. 0 Go to IronRidgexom/UFO XR Rails UFO/Stopper d d ' XR1000 Only I �/ d d d N/A Bonded Splice Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters Enphase - M250-72, M250-60, M215-60, C250-72 & Power Darfon - MIG240, MIG300, G320, G640 Optimizers I SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating =Class A Class A N/A Modules I Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. I RON RI DGE Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Flush hMMount LJ_J_J Tilt Mount Any Slope Test Setup ulaihiniType Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burnl A burni Flame Spread of Flame Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Type 1, 2, & 3 <_ 6 Degrees I Type 1, 2, & 3 Class A Class A 'Class A rated PV systems can be installed on Class A, B, and C roofs. Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV "system", and are covered in the certification. More Resources 97 Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class Afire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Engineering Certification Letters We offer complete engineering resources and pre -stamped certification letters. - UU LV 11 U....1UYt:.UU1 I. V If V11r41UYt:..U_.