approved FIR2022-0072+Fire_Sprinkler_Plan+7.26.2022_11.37.38_AM+3012732See South County Fire Remarks PAT) ORCHES DO NOT REQUIRE PROTECTION PER NFPA-1 3D 8.3.4. TYP. 1<0 CO E N 0'01 0 PIPING INSTALLED TIGHT TO BEDROOM 1 SPRINKLERS ARE SPACED BOTTOM CHORD OF ATTIC 1 0 '-0 " TO A MAX OF 20 'x20 ' TRUSSES AND TENTED PATIO WITHIN DASHED LINE. SEE DETAILON THIS PAGE. FAMILY RM 10 '-0 " 9'-0" loll• (10'MAX) 00 I o I � 0 0 0 DE,I Area#: 1 HAZARD: LIGHT Zme 1 SystEm Typa WET Q, V� Lrcatim LOFT �4 Qa•I FIONIng0itllsts: 2 SPRINKLERS ARE SPACED DEmity: 0 .1 0 REmdeArea 1 9 1 TO A MAX OF 20 'x20 ' ROOF Flom 4 0 .2gi-n @ 7 6 p2 a CdaJeticnSefe:y: 4pli .8 BATHROOMS UNDER 55 S.F. DO V II�ILl�S 0 gm Hcse�lONe /'NFPA-13D NOT REQUIRE PROTECTION PER 8.3.2, TYP. 11 BEDROOM 3 SAUNA BONUS RM 1 0 '-0 " 10 '-0 ' d16'-10" 9'-4" ui o W.I.C. lot • N 24 33 BATH 1 • 1 1 9,_0 • 4 15-0 1-8 �0 10-6 4 (10'MAX) 4'-0 N LOFT I a, • 1 6-5 10 '-0 = i 00 10'4 CLOSETS 24 DO 1"UPT ' 02 • DN UNDER S.F. ABOVE 1 1 1 NOT REQUIRE PROTECTION SPRINKLER PIPING INSTALLED TIGHT TO UTILITY 2-10 ,•3 4-1 - PER NFPA-1 3D 8.3.3, TYP. PROTECTION BOTTOM CHORD OF ATTIC o BATHROOMS UNDER 55 REQUIRED TRUSSES AND TENTED. SEE 04 E N S.F. DO NOT REQUIRE ABOVE RISER DETAILON THIS PAGE. El ® 10 I o VE PROTECTION PER 1 OV GE NFPA-1 3D 8.3.2, TYP. RISER LOCATION. CLOSETS UNDER 24 S.F. DO 0 0 E SEE DETAIL1 ON FP-1 NOT REQUIRE PROTECTION o 0 0 $,_1 PER NFPA-1 3D 8.3.3, TYP. BEDROOM 2 • o • 1 REMOTE Cn I 9'-0" - AREA #1 rn ENTRY (10'MAX) 4'-0" DECK GARAGE DOES NOT REQUIRE COVERED PORCH PROTECTION PER NFPA-1 3D 8.3.4 3 CAR GARAGE 1-1 /2" U.G. WATER 0o MAIN FLOOR FIRE PROTECTION PIPING PLAN SCALE: %8" = 1 '-0 " GENERALNOTES 1. INTERNATIONALBUILDING CODE (20 1 5) 1 .1 . SPRINKLERED AREA (APPROXIMATE - SEE ARCHITECTURAL PLANS FOR ACTUAL) MAIN FLOOR = 1 537 S.F. UPPER FLOOR = 1 883 S.F. 1.2. INSTALLATION STANDARDS: SPRINKLER SYSTEM DESIGNED AND INSTALLED PER NFPA-1 3D (20 1 3) 2. SPRINKLER PIPE TYPES: -WET- 2.1 . 1 " BRANCH LINES TO BE SPEARS CPVC PIPING WITH CEMENTED FITTINGS 2.2. 1 " MAIN TO BE SPEARS CPVC PIPING WITH CEMENTED FITTINGS 3. DESIGN CRITERIA ALLAREAS PROTECTED ACCORDING TO NFPA 1 3D WITH SPRINKLER FLOW DETERMINED BY REQUIREMENTS SET FOURTH BY NFPA 1 3D AND SPRINKLER HEAD LISTING DATA. PIPING IS SIZED ACCORDINGLY BY HYDRAULIC CALCULATIONS. REFER TO SPRINKLER HEAD DATA SHEETS FOR DISCHARGE CRITERIA. SPRINKLER PROTECTION IS PROVIDED FOR LIVING AREAS AND THE FOLLOWING AREAS PER 1 3D: • CLOSETS OVER 24 S.F. • BATHROOMS OVER 55 S.F. SPRINKLER PROTECTION IS NOT PROVIDED FOR THE FOLLOWING AREAS: • CLOSETS UNDER 24 S.F. PER 8.3.3 • BATHROOMS UNDER 55 S.F. PER 8.3.2 • PATIOS/PORCHES PER 8.3.4 • ATTIC PER 8.3.5 • GARAGE PER 8.3.4 4. NOTES: 4.1. ALLMATERIALTO BE NEW AND MEET U.L STANDARDS 4.2. HANGERS TO BE INSTALLED IN ACCORDANCE WITH NFPA 13 (20 1 3) - SEE PLAN FOR HANGING REQ. SYMBOLS USED ON DRAWINGS: +96" PIPE ELEVATION A.F.F OH1 ROOM HAZARD CLASSIFICATION (ALLROOMS ARE CONSIDERED LIGHT HAZARD UNLESS NOTED) F1 HYDRAULIC CALCULATION JUNCTION POINT 5. SCOPE OF WORK: 5.1. MODERN FIRE PROTECTION WILLBE INSTALLING A NEW SPRINKLER SYSTEM. THERE WILLBE ONE WET ZONE THAT WILLCOVER THE BUILDING. 5.2. ALLAREAS OF THE BUILDING TO BE INSTALLED AND COVERED IN ACCORDANCE WITH THE LOCAL AUTHORITY HAVING JURISDICTION AND PER NFPA 1 3D (20 13). TYPICALWALLSECTION See South County Fire Remarks UPPER F N U SCALE: Y8" = 1 '-0 " DECKS DO NOT REQUIRE PROTECTION PER N:PPA-13D 8.3.4, TYP. MASTER RM 1 0 '-0 " 4-2 3-2 CLOSET m 9'-0" 10'MAX) MASTER BATH 10 '-0 " Approved by Fire 08/15/2022 AFM /CFI tte er Approved set of plans must be on site at the time of inspection. Failure to provide the approved set may result in a re -inspection fee. System drain(s) required at riser and must drain to the exterior. If riser is above lowest grade, 2nd drain required and signage at riser indicating location. Systems require signage IAW NFPA 13D. Coverage required to the following areas: Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater the T and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area. When fuel fired equipment is present on covered decks or porches, or if living space above, at least one quick -response intermediate temperature sprinkler shall be installed above the equipment or area under living space. All fuel fired appliances, except attics if above all living areas. LDOR FIRE PROTECTION PIPING PLAN PIPING RAN TIGHT ON TOP OF BOTTOM CHORDS OF ATTIC TRUSSES TO KEEP PIPING AS CLOSE TO WARM SPACE AS POSSIBLE. THICKNESS MUST BE ADEQUATE TO SUSTAIN WATER FILLED PIPE @ 40 DEGREES AT ALLTIMES VISQUEEN TO ACT AS A THERMAL BARRIER (BY � INSULATION (BY OTHERS) OTHERS) PIPE CLAMP )—B _ LPIPE WOOD JOIST STEELSCREW GYP. BOARD CLG. NOTES: • DO NOT INSTALL INSULATION BETWEEN THE SPRINKLER PIPING AND THE CEILING. • THE VISQUEEN AND INSULATION, PLACED OVER THE SPRINKLER PIPING, IS NECESSARY TO ACT AS A THERMAL BARRIER. • ADEQUATE HEATING MUST BE MAINTAINED BY OTHERS, AT ALLTIMES. TENTING DETAIL RISER LEGEND 1 . 1-1 /2' UNDERGROUND WATER SERVICE (BY OTHERS) (FLUSHING & TESTING OF THE UNDERGROUND SHALLBE COMPLETED PRIOR TO THE SPRINKLER SYSTEM HOOKUP. UNDERGROUND PAPERS ARE TO BE SUPPLIED TO THE "FP" CONTRACTOR BY THE G.C.) 2. 1-1 /2' x 1" REDUCER 3. 1 " AMES 20 0 0 B BACKFLOW PREVENTER 4. 1" RISER MANIFOLD w/ FLOW SWITCH, PRESSURE GAUGE, & TEST AND DRAIN 5. 1 " THREAD X CPVC ADAPTER 6. 1 " TO SYSTEM 7. MAIN DRAIN PIPED TO OUTS"r)E ALLWIRING/INTERFACING OF ALARMS BY OTHERS "ALLPIPING PENETRATING THE EXTERIOR WALLTO BE GALVANIZED RISER DETAIL 1 SCALE: 1 " = 1 '-0 " 2 SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# ESCUTCHEON Q 22 PENDENT WHITE 165 4.9D 1/2" RAO 616 RELIABLE RFC CONCEALED 2 PENDENT WHITE 212 4.�D 1/2" RAO 616 RELIABLE RFC CONCEALED ® 1 PENDENT WHITE 286 1 5.60 1/2" RA1414 RELIABLE I F1FR56 I EXTENDED SPRINKLER HEAD LEGEND el ,, ;e ,Wood i' ManLE- i SAMMY Scrav - — _AT Rod Hagf Rirg IPS AUTOGRIP HANGER (SAMMY SCREW) z "I fel SAMMY ScreN i , f't HaT Erg IPS AUTOGRIP HANGER (SIDE SAMMY SCREW) HANGER DETAILS ManLE- WOOD SCREW WOOD SCREW MAIN OR BRANCH `\ LINE NO BLOCK HANGER CPVC NO BLOCK HANGER FIR2022-0072 RECEIVED Aug 03 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Jared Reid Van Gammeren 9130-0820-C II Modern Fire Protection. LLC N MODERFP804MA d a Elmo, � Expires � Slgnatur n 12131122 MAXIMUM DISTANCE BETWEEN HANGERS (FT. —IN.) NOMINALPIPE SIZE (IN.) Y4„ Y4" 1 Y2" 2„ 2 Y2" 3„ 4„ 6„ 8„ SPEARS CPVC 5-6 6-0 6-6 7-0 8-0 90 10 -0 NA NA NA NFPA 13 HANGER SPACING FIRE SPRINKLER RISER. SEE DETAIL1 ON FP-1 0o SITE PLAN Nl�) SCALE: 1 " = 2 5'-0 " JOHN TRANG RESIDENCE FIFE: 2 %-0 " 1 " WATER METER 37 -75' 1-1 /2" WATER LINE (BY OTHERS) FLOW T ES T IN STATIC: 1 19PS1 RESID: 75 PSI FLOW: 1743 GPM DATE: 0 6/13/22 FLOW TEST INFORMA' PROVIDED BY CITY O EDMONDS ON 0 6/13/. ELEV: -29) �J SCALE: %$" = 1 '-0 "