Loading...
APPROVED BLD2021-1562+Architectural_Plan+11.16.2021_3.04.51_PM+2523591GENERAL STRUCTURAL NOTES GENERAL ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, OR OTHER GOVERNING CODE, AS REQUIRED BY LOCAL JURISDICTION. DESIGN PARAMATERS WIND: NOMINAL WIND SPEED — 85 MPH RISK CATEGORY II ULTIMATE WIND SPEED — 110 MPH IMPORTANCE, 1 = 1.0 WIND EXPOSURE, B KZT = 1.38 SEISIMIC: EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE, le = 1.0 SS = 1.295 SITE CLASS, D S, = 0.457 SEISMIC DESIGN CAT., D SDI = 1.04 SEIS. FORCE RES. SYS, A.15. SD, = NA DESIGN BASE SHEAR = 2291 Ibs CS = 0.16 RISK CATEGORY II R = 6.5 LIVE LOADS: ROOF 25 (SNOW) FLOOR 40 PSF DECKS 60 PSF INSPECTIONS NO SPECIAL INSPECTIONS ARE REQUIRED. VERIFY INSPECTIONS REQUIRED WITH AUTHORITY HAVING JURISDICTION. SOILS REPORT NOT PROVIDED. FOUNDATIONS EXTEND FOOTING TO UNDISTURBED SOIL OF 2000 PSF BEARING CAPACITY. BOTTOM OF EXTERIOR FOOTING SHALL BE V-6" MINIMUM BELOW OUTSIDE FINISHED GRADE. COMPACTED FILL SHOULD CONSIST OF PREDOMINATELY WELL -GRADED, GRANULAR SOIL, FREE OF ORGANIC MATERIAL AND DEBRIS. FILL SHOULD BE PLACED IN MAXIMUM 8" LOOSE LIFTS AND COMPACTED TO A MINIMUM OF 95 PERCENT OF THE MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED BY ASTM D-1557 TEST PROCEDURES. CONCRETE f', = 2500 PSI MINIMUM 5'/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF 6.0 GALLONS OF WATER PER 94 LB SACK OF CEMENT. MAXIMUM SLUMP IS 4". SEGREGATION OF MATERIALS TO BE PREVENTED. REINFORCING STEEL #5 BARS AND LARGER SHALL BE GRADE 60 DEFORMED BARS, AND #3 AND #4 BARS SHALL BE GRADE 40, IN ACCORDANCE WITH ASTM A-615. LAP SPLICES 32 BAR DIAMETERS. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 AND SHALL BE 6X6 — W1.4 X W1.4. LAP ONE FULL MESH AT SPLICES. TIMBER FRAMING SHALL MEET THE FOLLOWING MINIMUM STANDARDS: BEAMS AND POSTS (4x_ AND GREATER):DF-L#2 JOISTS / STUDS (2x_): HF#2 / STUD GLUE LAMINATED BEAMS (GLB) 24F-V4 (24F-V8 AT CANTILEVERS) PARALLAM BEAMS (PSL) 2.0E UNO 2x TIMBER SHALL BE KILN DRIED. GRADES SHALL CONFORM TO "WWPA GRADING RULES FOR WESTERN LUMBER", LATEST EDITION. ROOF TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE T.P.I. AND THE IBC. ALL CONNECTIONS PER IBC TABLE 2304.10.1 (SEE BELOW). NOTE ALL BEAMS/HEADERS TO BE SUPPORTED BY MINIMUM DBL 2x POSTS AT EACH END, UNO ROOF DIAPHRAGM INSTALL MINIMUM 1/2" CDX PLYWOOD (32/16) OR 7/16" OSB SHEATHING. NAIL ALL SUPPORTED EDGES AND BOUNDARIES WITH 8d AT 6" O.C, AND INTERIOR SUPPORTS WITH 8d AT 12" O.C.; BLOCKING NOT REQUIRED. FLOOR DIAPHRAGM INSTALL MINIMUM 23/32" T&G STURD-I-FLOOR (24oc) SHEATHING. GLUE AND NAIL ALL SUPPORTED EDGES AND BOUNDARIES WITH 10d AT 6" O.C.; AND INTERIOR SUPPORTS WITH 10d AT 12" O.C., BLOCKING NOT REQUIRED. MISCELLANEOUS THE CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS AT JOB SITE. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENINGS HAVE BEEN INSTALLED. DO NOT SCALE DRAWINGS. PRE -FABRICATED ELEMENTS TO BE HANDLED AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. MINIMUM FASTENING SCHEDULE (UNO) (PER 2018 IBC TABLE 2304.10.1 SHEARWALL SCHEDULE Date: 10/27i2021 Job #: 1450 SHEATHING - APPLY TO SHEATHING EDGE NAILS *(5) ROOF TO TOP PLATE, MARK BASE PLATE SILL PLATE ANCHORS w/ *(2) 2x HF STUDS @ 16"o/c ALL EDGES BLOCKED NAILS *(5) FLOOR TO TOP PLATE 3" x 3" x 1/4" WASHERS *(8) U.N.O. BELOW *(9) (do not penetrate past flush) & SILL PLATE *(6) SW-1 7/16" OSB 8d @ 6" o/c (12" o/c field) 16d @ 12 " o/c �� H1 @ 24 o/c 5/8" OXIO" AB's @ 60 " o/c or A35 A 24 " o/c SW-2 7/16" OSB *(7) 8d @ 3" o/c (12" o/c field) 16d @ 6 " o/c A35 @ 20 " o/c 5/8" Ox10" AB's @ 48 " o/c HOLDOWN SCHEDULE Date: 10/27/2021 Job #: 1450 HOLDOWN / FASTENERS TO FOUNDATION MARK STRAP *(1) (2)-STUDS MIN U.N.O. ANCHOR *(1)(4) COMMENTS T-1 STHD10/10RJ (28) - 16d N/A SHEAR WALL AND HOLDOWN NOTES (1) HOLDOWNS TO BE SIMPSON OR EQUIVALENT WHERE EQUIVALENT IS PERMITTED. LOCATE HOLDOWNS AT ENDS OF SHEARWALLS, UNO. INSTALL PER MANUFACTURER RECOMMENDATIONS FOR FOUNDATION MINIMUM END DISTANCE AND EMBEDMENT. EXTEND, THICKEN, DEEPEN, ETC. FOUNDATION TO MEET THE MANUFACTURER'S SPECIFICATIONS. (2) CONSTRUCT CRIPPLE WALLS AND PONY WALLS TO MATCH SPECIFICATIONS OF THE SHEAR WALL ABOVE. CONSTRUCT GABLE END WALLS TO MATCH SPECIFICATIONS OF THE SHEAR WALL BELOW. CONSTRUCT CLERESTORY WALLS PER SW-1, UNO. ALL EXTERIOR WALLS TO BE CONSTRUCTED PER SW-1, UNO. (3) 3X OR DBL 2X SILL PLATE REQUIRED. (4) USE THREADED ROD AND COUPLER AS REQUIRED. (5) COMMON NAILS, UNO: 8d = 0.131" x 21/2" 10d = 0.148" x 3" 12d = 0.148" x 31/2" 16d = 0.148" x 3'/4" (6) INSTALL H1 CLIPS AT EACH TRUSS/RAFTER END. INSTALL A35 @ 24" OC AT EACH GABLE END AND RIM JOIST (OR SOLID BLOCKING) TO TOP PLATE AND MUDSILL CONNECTION, UNO. WHERE SPACING TIGHTER THAN 24" OC IS SPECIFIED, INSTALL A35 CLIPS FROM SOLID BLOCKING TO DBL TOP PLATE, AND INSTALL H1 OR H2.5 CLIPS TO EACH TRUSS/RAFTER END. LTP4, LTP5 or LS50 CAN BE SUBSTITUTED FOR A35 CLIPS PER SIMPSON. (7) MINIMUM 3X OR DBL 2X STUDS REQUIRED AT ABUTTING PANEL EDGES. DBL STUDS TO BE LAMINATED W/ (2) 16d @ 6" OC. (8) ANCHOR BOLTS SHALL BE EMBEDDED 7" MINIMUM INTO CONCRETE. MIN (2) BOLTS PER PIECE WITH ONE BOLT LOCATED NOT MORE THAN 2" OR LESS THAN (7) BOLT DIAMETERS FROM EACH END OF THE PIECE. MUD SILL TO BE 2X MINIMUM AND PRESSURE -TREATED. (9) ALL SHEATHING TO BE APA RATED. SEE GENERAL STRUCTURAL NOTES. NO. CONNECTION NAILING, LOCATION (UNO) 1 BLOCKING BETWEEN JOIST/RAFTER OR TRUSSES TO TOP PLATE OR OTHER FRAMING ABOVE (3) 8d, TOENAIL EACH END 2 BLOCKING BETWEEN JOIST/RAFTER OR TRUSSES NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS (2) 8d, TOENAIL EACH END 16d FACE NAIL (3) 8d, TOENAIL (3) 16d 3 FLAT BLOCKING TO TRUSS AND WEB FILLER 4 JOISTS TO TOP PLATE OR GIRDER 5 CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS (NO THRUST) 6 COLLAR TIE TO JOIST/RAFTER (3) 10d 7 ROOF TRUSS TO TOP PLATE ROOF JOIST/RAFTER TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTER TO 2" RIDGE BEAM STUD TO STUD (NOT AT SHEAR WALLS) CONTINUOUS HEADER TO STUD (3) 10d, TOENAIL (2) 16d, END NAIL 16d @ 24" O.C., FACE NAIL (4) 8d, TOENAIL 8 9 10 11 TOP PLATE TO TOP PLATE, AT END JOINTS (8) 16d, EACH SIDE OF END JOINT, FACE NAIL (MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT) 12 SILL PLATE TO JOIST, RIM JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 16d @ 16" O.C., FACE NAIL 13 SILL PLATE TO JOIST, RIM JOIST OR BLOCKING AT BRACED WALL PANELS (3) 16d @ 16" O.C., FACE NAIL 14 STUD TO SILL PLATE (4) 8d, TOENAIL OR (2) 16d, END NAIL* 15 TOP PLATE TO STUD (2) 16d, END NAIL (2) 16d, FACE NAIL (2) 8d, FACE NAIL 16 TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 17 1" BRACE TO EACH STUD AND PLATE 18 1" x 6" SHEATHING OR LESS TO EACH BEARING (2) 8d, FACE NAIL 19 1" x 8" AND WIDER SHEATHING TO EACH BEARING (3) 8d, FACE NAIL 20 JOIST TO SILL, TOP PLATE OR GIRDER (3) 8d, TOENAIL 21 RIM JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW 8d @ 6" O.C., TOENAIL 22 1" x 6" SUBFLOOR OR LESS TO EACH JOIST (2) 8d, FACE NAIL 23 2" SUBFLOOR TO JOIST OR GIRDER (2) 16d, BLIND AND FACE NAIL 24 2" PLANKS (PLANK & BEAM - FLOOR & ROOF) (2) 16d, EACH BEARING, FACE NAIL 25 BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS 20d @ 32" O.C., FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES AND (2) 20d AT ENDS OF EACH SPLICE 26 LEDGER STRIP SUPPORTING JOISTS OR RAFTERS (3) 16d, EACH JOIST OR RAFTER, FACE NAIL 27 28 JOIST TO RIM JOIST BRIDGING OR BLOCKING TO JOIST (3) 16d, END NAIL (2) 8d, EACH END, TOENAIL CONCRETE COVER FOR REINFORCING STEEL MIN. ROOF SHEATHING PER GENERAL STRUCTURAL NOTES kTED ROOF TRUSSES 4ANUFACTURER VENTED BLOCKING PER PLAN WITH EDGE NAILING PER STRUCTURAL NOTES SHEAR WALL PER PLAN 1 TYPICAL SHEAR FLOW S1 ROOF TO SW NTS EXTERIOR SLAB OR FINISHED GRADE PER PLAN SHEAR WALL ABOVE W/ ANCHORS PER SW SCHED 4" FLOOR SLAB W/ #3 @ 12" OC EW OR 6x6 W1.4xW1.4 WWF - INSULATION BY OTHERS 6" STEM WALL W/ (1) #4H TOP #4H @ 16" OC #4V @ 18" OC W/ ALT STD HOOKS 12"x8" CONCRETE FOOTING W/ (2) #4 CONTINOUS 4" MIN FOOTING DRAIN IN GRAVEL POCKET BEARING SOIL 3 TYPICAL FOUNDATION GARAGE S1 42" OR LOWER NTS Reinforcing Bar Location Min Concrete Cover UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS AND LARGER) 2" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS AND SMALLER) 1 1/2" COLUMNS AND BEAMS w/ BARS ENCLOSED IN STIRRUPS, TIES OR SPIRAL REINF 1 1/2" (TO PRIMARY REINF) SLABS, JOISTS AND INTERIOR FACES OF WALLS (#6 BARS AND LARGER) db + 5/8" SLABS, JOISTS AND INTERIOR FACES OF WALLS (#5 BARS AND SMALLER) 3/4" 2-HOUR AND 3-HOUR SLABS (REFER TO PLAN NOTES) CLEAR SPACING BETWEEN PARALLEL BARS IN A LAYER (BARS ENCLOSED IN STIRRUPS/TIES) 1„ CLEAR SPACING BETWEEN PARALLEL BARS IN A LAYER (NO STIRRUPS/TIES) 2db CLEAR SPACING BETWEEN (2) OR MORE PARALLEL LAYERS 1" NOTES: 1. WHERE A THICKNESS OF COVER REQUIRED FOR FIRE PROTECTION IS GREATER THAN THAT SPECIFIED IN THIS TABLE, THE GREATER THICKNESS SHALL BE USED. 5 MINIMUM STEEL REQUIREMENTS S 1 NTS No Plumbing or Mechanical has been included as part of this permit. It is assumed that this structure will not be heated or cooled. If the structure is to be conditioned by fixed equipment a revised plan must submitted for review and approval. CONC WALL & REINF PER PLAN TYP FOOTING REINF PER PLAN ADD (1) #5 DIAG IN WALL ADD BARS TO MATCH TYP FOOTING REINF, LAP BARS AS REQ'D PER LAP SPLICE LENGTH TABLE FACE OF STEPS SHALL BE CAST AGAINST UNDISTURBED EARTH. IF EXCAVATION RAVELS, BACKFILL WITH CONCRETE WHEN FOOTING IS CAST. _/ 2 x H MIN, TYP tf TYP BOT OF EXCAVATION NOTES: 1. FOR EXCAVATION INFORMATION, SEE TYPICAL FOOTING EXCAVATION DETAIL. i; TYPICAL STEPPED FOOTING S 1 NTS ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE GABLE END TRUSS AND BRACE PER MANUF'R W/ 7/16" OSB PER SW-1, LINO TOP CONNECTION PER SW SCHEDULE SHEAR WALL PER PLAN 2 TYPICAL SHEAR FLOW S1 GABLE TO SW NTS INUOUS LONGITUDINAL ORCEMENT PER PLAN OOKS INTO SECTING FTG ER BAR AROUND DE CORNERS 18 18" HORIZONTAL BARS PER PLAN VERTICAL BARS PER PLAN STD HOOKS INTO INTERSECTING WALL ;ALTERNATE DIRECTIONS) CORNER BAR AROUND ALL 18, OUTSIDE CORNERS 181, 4 TYPICAL CORNER BARS S 1 NTS 1/8"A-1/2" PRE -MOLDED CONT. MASTIC JOINT STRIP (JOINT MAY BE SAW -CUT AT CONTRACTOR'S OPTION) i SAWCUT 1/3 SLAB DE Control Joint SLAB ON GRADE PER PLAN BURKE "KEYKOLD" JOINT, STOP REINF 1" CLEAR OF JOINT EA. SIDE, 1/8" RADIUS ON EDGES SLAB ON GRADE WHERE SLAB IS EXPOSED / PER PLAN 2' - 0" LAP Construction Joint NOTES: 1. SAWED JOINTS SHALL BE MADE AS SOON AS THE JOINT CAN BE CUT WITHOUT EDGES RAVELING AND WITHIN 24 HOURS OF SLAB PLACEMENT. 2. SAWED JOINTS SHALL BE FITTED WITH SEALENT AS COORDINATED WITH THE ARCHITECT. 7 TYPICAL SLAB JOINTS S 1 NTS FOUNDATION @ POTENTIAL S1 GARAGE OPENING NTS 4" MIN CONC SLAB W/ #3 @ 12" OC EW -OR- 6x6 - 1.4Wx1.4W WWF 4" WASHED PEA GRAVEL (4) #5 BARS CONT FIRM BEARING SOIL co Ln o i U M6 W C-0 ^n U N J W J w � { ' w Y .. Q � J O n � W U LU .. w - 1-1 uJV J W O W U 00 U) wa Q � ~w C.0 U N > CD C: w N U) UPSTATE STAMP W Q C) Ld_ Q Z O z w CD�O O DD rn � O p (y) c)UQM Lij J U) V 0— W_j J O T_ V­ 0 0 2 U) , �W n 1450 JBG AMG REVISION DATE: DESCRIPTION: 10/27/2021 SAVE DATE APPROVALS RECEIVED Nov 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S1 *USE (4) 16d END NAIL STUDS TO TOP AND SILL PLATES AT 2x10 STUDS M Lo ' O I-- U a� N W C) . _ U o �KJ W Lu W Y J Z U N W � U -------------------------------------------------------------- ALLOWABLE RIDGE HT=104.8' H ------------------------------------------------------------------------------------------- Wcn ACT RIDGE HT - 104.2" \LJ Q 2 cf) ~ W coo U N > O O W N (n UPSTATE STAMP 1' 14'-4" M. W A 0 442 �p 0 N A L Q� a 11 i10i2021 ------ ------------------------------------------- ------------------------- ----------------------------------------------------------- AVG GRADE = 89.8" NORTH EAST U) z O Q w J W W Q O ------------------- - - - - - -RIDGE - - - - - - - - - - - - - - - - - - -- Q O Q O O Z Z 00 O QW0)cM c�UQM QQo o Z j wT,--Ov 2 u)�Lw0- 0 0 ------------TOP OF CONCTRETEL L 4 Q d UPSTATEJOB# DRAWN BY: CHECKED BY: a ° 1450 JBG AMG a �c--——————————————————————— — — — — —— d REVISION DATE: DESCRIPTION: 10/27/2021 SAVE DATE SOUTH WEST APPROVALS RECEIVED Nov 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT .0, - - - - - - 8 S1 FOUNDATION 4 - - 2'-6" FOUNDATION NOTES - LUMBER IN CONTACT WITH CONCRETE OR EXPOSED TO WEATHER TO BE PRESSURE -TREATED - HARDWARE AND FASTENERS IN CONTACT WITH CONCRETE, IN USE WITH PRESSURE -TREATED LUMBER, AND/OR EXPOSED TO WEATHER SHALL BE HOT -DIPPED GALVANIZED OR OTHER APPROVED MATERIAL - SEE TYPICAL FOUNDATION DETAILS ON SHEET S2 - ADDITIONAL DIMENSIONS TO BE DETERMINED FROM ARCHITECTURAL PLANS - EMBEDDED HOLD DOWNS TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS ROOF FRAMING PLAN 0 9 T-1 T cp I T- 24'-0" O O LOWER FLOOR 4 ROOF FRAMING NOTES & BEAM NUMBERS (SEE CALCULATIONS) LATERAL NOTES 02100215 - CONSTRUCTION OF EACH DIAPHRAGM TO BE PER THE STRUCTURAL NOTES ON SHEET Si - ALL SHEAR WALL CONNECTIONS TO BE PER THE SHEAR WALL SCHEDULE - SEE ADDITIONAL SHEAR WALL NOTES ON SHEET S1 - PLEASE NOTIFY UPSTATE ENGINEERING OF ANY STRUCTURAL PLAN REVISIONS, INCLUDING WINDOW /DOOR LOCATIONS, PRIOR TO INSPECTION co LC) U CD Il_ m� s W Q� J u W ui Y .. Q ` Z D W O n1 � W C7 U N w ���rtu�lJJ O U uco �U) w Q� ~w coo U N � CD CD w NU) UPSTATE STAMP zry (D LLI U) LLI Q J (D azz �oQ Z)a� 0 LL �00 U)LLOf - ALL BEAMS/HEADERS TO BE 4X8 DF#2 MINIMUM, UNO LLI - PREFABRICATED TRUSS DESIGN TO BE (D O PROVIDED BY MANUFACTURER. ANY ry � CHANGES RESULTING FROM TRUSS DESIGN Q O 00 C:) TO BE PROVIDED TO UPSTATE ENGINEERING, 0 N ;I- INC BEFORE PROCEEDING. z z � LLI M O co - ALL BEAMS/HEADERS TO BE SUPPORTED co U Q T-- WITH DBL 2X POST EA END, UNO J co W C/ cV - ALL POSTS TO BE SUPPORTED WITH LIKE 0 0 _j POSTS TO FOUNDATION, UNO W O U J 2 ry C� n LUI UPSTATE JOB# DRAWN BY: CHECKED BY: 1450 JBG AMG REVISION DATE: DESCRIPTION: 10/27/2021 SAVE DATE APPROVALS RECEIVED Nov 17 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S3