REVIEWED BLD2022-0475+Manufacturer_Specifications_and_Installation_Instructions+4.12.2022_8.42.10_AM+2796334
RECEIVED Apr 14 2022 Job Name. CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT Tag# BLD2022-0475 ir r F EDMO S Submittal Data Sheet FTXS09L 0.75-Ton Wall Mounted Heat Pump System rw j� / /.a,. r� _ Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Indoor Specifications Airflow Rate (cfm) Cooling Heating H M H M 381 279 420 321 L SL L SL 194 145 233 219 Sound(dBA) H/M/L/SL 41/33/25/22 42/35/28/25 Dimensions (H x W x D) (in) 1 11-5/8 x 31-1/2 x 8-7/16 Weight (Lbs) 120 Outdoor Specifications I Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 2.43 Refrigerant Oil PVE (FVC50K) Airflow Rate (cfm) Cooling Heating H 1,102 H 992 989 L 840 Sound Power Level (dBA) 47 / 48 Dimensions (H x W x D) (in) 21-5/8 x 30-1/8 x 11-1/4 Weight (Lbs) 75 Efficiency Cooling Heating SEER 24.5 HSPF 12.5 EER 15.3 COP 4.46 Performance Cooling (Btu/hr) Rated (Min/Max) 9,000 (4,400 / 10,600) Sensible @ AHRI 8,100 Moisture Removal gal/h .3 Standard Operating Range 50°F —115°F Extended Operating Range* 0°F — 115" Rated Cooling Conditions: Indoor: 80T DB/67'F WB Outdoor: 95T DB/75°F WB *With field settings and wind baffle Heating (Btu/hr) 1: @ 47' Rated (Min/Max) 12,000 (4,400 / 15,600) 2: @ 17` Rated 7,700 3: @ S*: Capacity / COP 5,370 / 3.02 Operating Range 5°F — 65°F 1: Rated Heating Conditions: Indoor: 70'F DB/60°F WB Outdoor: 47°F DB/43°F WB 2: Rated Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB 3: Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB Electrical 208/60/1 230/60/1 System MCA 8 8 System MFA 15 15 Compressor RLA 3.2 2.9 Outdoor fan motor FLA .22 .22 Outdoor fan motor W 23 23 Indoor fan motor FLA .15 .15 Indoor fan motor W 23 23 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) 1/4 Gas (in) 3/8 Drain (in) 5/8 Max. Interunit Piping Length (ft) 65.6 Max. Interunit Height Difference (ft) 49.2 Chargeless (ft) 32.8 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: October 2021 Page 1 of 4 a 0 J O U) X I_ H THE MARK (�) SHOWS PIPING DIRECTION 31-112 (800mm) REAR LEFT RIGHT 0AIRFLOW (INDOOR) INCLUDING l l MOUNTING PLATE! B-9116 (217mm) z 8-W16 (215mm) 1-15116 (50mm) MIN (SPACE FOR MAINTENANCE) GRILLE E NAME PLATE iCREWS E Lo N TERMINAL BLOCK WITH GROUND TERMINAL BOTTOM LOUVERS SIGNAL RECEIVER 'INTELLIGENT EYE SENSOR OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP EEEEEEEEE INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) MODEL NAME PLATE SIGNAL TRANSMITTER BLADE ANGLES 2-5/16 (58mm) 11116 (18mm) UP/DOWN (AUTOMATIC) COOLING, DRY HEATING FAN o 0 0 E C] 15° 0 0 5° o rl co 35° 30,�,/ 30°� .05 45° 55' 65° 65° 70- 80° RIGHTILEFT (AUTOMATIC) WIRELESS REMOTE CONTROLLER (ARC452A21) � w U Z 0LL 02 co W W o aoLL m C? d W r N � 1-15116 (50mm) MIN REQUIRED SPACE (SPACE FOR MAINTENANCE) GAS PIPE ¢318 (09.5mm) CuT ` DRAIN HOSE (THE LENGTH OF PIPE OUTSIDE (CONNECTING PART THE UNIT: ABOUT 13-3I4 (350mm)) O.D. 0518 (016mm) LIQUID PIPE 0114 (p6.4mm) CuT THE HOSE LENGTH OF OUTSIDE E (THE LENGTH OF PIPE OUTSIDE THE UNIT IS APPROX. 1 B-5116 (465mm)) E THE UNIT: ABOUT 15-314 (400mm)}Lo 31-112 (800mm) v 23-1116 (586mm) `T 5-314 (145.5mm rn I I I I I � rn I Ia WALL HOLE FOR WALL HOLE 2-3/8 (60mm) EMBEDDED PIPING �2 92- {165mm) HOLE 6 59.5mm 02-9116 (05mm) HOLE STANDARD LOCATIONS OF WALL HOLES C:3DO74094A 0 N m a ti 0 N v 0 O v 0 0 cc E 7 N 0 a 0 0 s m •3 a, on v a c 0 r- MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE `o =LESS THAN 47-1/4 E 4-HOLES FOR ANCHOR BOLTS r DRAIN OUTLET / Ln (I.D 05/8 HOSE FOR CONNECTION) (M8 OR M10) O o c 22-5/8 4-1l8 co o x u w cv 19.5li C! 7 N cLLo N 1-15/16 1 15116 o c o 1-15116 on C N o m a fli b0 r -a m M LL o u C E ,C HANDLE "' ° \ BRAND NAME LABEL o lf1 S L TRAMINAL Ln 11-114 5/16 112 30 1/8 � 2-112 rtannu irnnTi in— WITH GROUND ITRAMINAL C)IIMC)OR AIR THFRMISTC]R (-? a 3 11RING J LET CONDUIT MOUNTING PLATE / 7-11/16 SERVICE IN CASE OF REMOVING PORT STOP VALVE COVER LIQUID STOP VALVE (01/4CuT) J Y C 0 E �, c Q r= t Y o z o c fo c O E a Q E 0 S E � N GAS STOP VALVE o 0 N (0318 CuT) o v n u � ai u 0 O �n ui v o s cc Y Y E 0 .0 v N Optional Accessories - DAIK►N Indoor Unit Included Part Number Description AZAI6WSCDKB DKN Residential Cloud Wi-Fi Adaptor for Single- and Multi -Zone System S21 AZAI6WSPDKC DKN Plus Interface DTST-ONE-ADA-A Daikin One+ Smart Thermostat for Ductless Products BRC944B2 Wired Remote Controller BRCW90IA08 Wired Remote Controller Cable — 25ft BRCW901AO3 Wired Remote Controller Cable — 1Oft DACA-CPI-I Inline Condensate Pump Fits inside all Daikin wall & floor mount units DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Included Part Number Outdoor Unit DACA-WB-3 7Description der -Coated Wall -Mounted Bracket KEH041A41 in Pan Heater RXS09 12LV KKP937A4 Drain Plug for OD Unit KPW937F4 Low Ambient Wind Baffle / Air Adjustment Grille 09/12 MBH Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: October 2021 Page 4 of 4 Job Name: DAIKIFN Tag# Submittal Data Sheet FTXS18LVJU / RXS18LVJU 1.5-Ton Wall Mounted Heat Pump System —_- Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Indoor Specifications Airflow Rate (cfm) Cooling Heating H M H M 583 484 625 526 L SL L SL 385 360 431 399 Sound(dBA) H/M/L/SL 46/41/36/33 45/40/35/32 Dimensions (H x W x D) (in) 1 13-3/8 x 41-5/16 x 9-3/4 Weight (Lbs) 131 Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 3.97 Refrigerant Oil PVE (FVC50K) Airflow Rate (cfm) Cooling Heating H 1,780 H 1,444 L 1,494 L 1,328 Sound Pressure Level (dBA) 49 Dimensions (H x W x D) (in) 28-15/16 x 32-1/2 x 11-13/16 Weight (Lbs) 104 Efficiency Cooling Heating SEER 20.3 HSPF 11.0 EER 12.7 COP 3.70 Performance Cooling (Btu/hr) Rated (Min/Max) 18,000 (5,800 / 18,000) Sensible @ AHRI 14,790 Moisture Removal gal/h 1.0 Standard Operating Range 50°F —115°F Extended Operating Range* 0°F —115°F Rated Cooling Conditions: Indoor: 80'F DB/67'F WB Outdoor: 95°F DB/75°F WB *With field settings and wind baffle Heating (Btu/hr) 1: @ 47* Rated (Min/Max) 21,600 (5,800 / 21,600) 2: @ 17°Rated 13,900 3: @ 5*: Capacity / COP 9,650 / 2.5 Operating Range 5°F — 65°F 1: Rated Heating Conditions: 2: Rated Heating Conditions: 3: Heating Conditions: Indoor: 70T DB/60°F WB Outdoor: 477 DB/43'F WB Indoor: 70T DB/60°F WB Outdoor: 177 DB/15'F WB Indoor: 70'F DB/60'F WB Outdoor: 57 DB/5'F WB Electrical 208/60/1 230/60/1 System MCA 13.75 13.75 System MFA 20 20 Compressor RLA 6.6 5.9 Outdoor fan motor FLA .32 .32 Outdoor fan motor W 53 53 Indoor fan motor FLA .32 .32 Indoor fan motor W 48 48 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) 1/4 Gas (in) 1/2 Drain (in) 5/8 Max. Interunit Piping Length (ft) 98.4 Max. Interunit Height Difference (ft) 65.6 Chargeless (ft) 32.8 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: October 2021 Page 1 of 4 a 0 m O . U) W J 00 T_ U) X I_ H } THE MARK (-� )SHOWS PIPING DIRECTION 1 AIRFLOW (INDOOR) LEFT I REAR 41-5116 (1050mm) RIGHT INCLUDING INSTALLATION PLATE 9-13116 (250mm) 9-3/4 (248mm) I I 1■ �^I • 1 . 1 FRONT E NAME PLATE GRILLE o FIXING SCREWS w TERMINAL BLOCK (INSIDE) m WITH GROUND TERMINAL (INSIDE) BOTTOM } INTELLIGENT EYE SENSOR I ISHIVJIVII I I Ct5 2-5/16 (58mm) 11116 (18mm) E m 0❑� WIRELESS REMOTE CONTROLLER (ARC452A21) OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) NAME PLATE T$VKCIE_ bP�ED S ST7�GEF - MAINTENANCE) MAINTENANCE) GAS PIPE �1/2 (012.7mm) CuT' (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15-3/4 (400mm)) LIQUID PIPE 01/4 (�6.4mm) CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 18-1/8 (460mm)) BLADE ANGLES UP/DOWN (AUTOMATIC) COOLING, DRY HEATING FAN E 15° 15° Q 2 e25�� 30° c� I 50° 60° A40W' 5° 5° 75° 70° 70° RIGHT/LEFT (AUTOMATIC) 4s° >4 41-5/16 37-5116 DRAIN HOSE (CONNECTING PART O.D. o5/8 (016mm) THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 18-5/16 (465mm)) WALL HOLE FOR EMBEDDED WALL HOLE PIPING �3-1/8 (080mm) HOLE 03-1/8 (080mm) H( 2-9116 (65mm) 3-1/2 (89m STANDARD LOCATIONS OF WALL HOLES 1-3/8 r, T C:30074024A 0 N m a 0 HANDLE W JM W lr-- c / X ry DRAIN OUTLET (I.D.05/8 HOSE FOR CONNECTION WITH DRAIN JOINT) 12-13116 4-718 22-13116 MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE `O =LESS THAN 47-1/4 r v � r M a M 1-15116 47 IN CASE OF REMOVING STOP VALVE COVER 4-HOLES FOR FOUNDATION BOLTS MANUFACTURER'S LABEL (M8 OR M10) BRAND NAME PLATE I WIRING INLET TERMINAL STRIP ' ICI CAUTION LABEL I CONDUIT MOUNTING PLATE / 6-5116 LIQUID STOP VALVE 0�1 /4 CuT) SERVICE PORT WITH GROUNDTERMINAL N m GAS STOP VALVE (�112 CuT) OUTDOOR TEMPERATURE THERMISTOR a 0 0 s M 3 � v a N Y N C 0 `o c c t0 N 0 0 x u c ai a O N 7 C O O OD 2 m O N O In u O W 7 7 O m (n a ou C iy O u C E •� n o 0 NtLo S L In 3 v � Y C J m V � U N N O E L C a s c ++ Y O p Z p E N Y � m aI p E N O Q E O 7 c ti 7� N O O u N O N n ai u H O L Y m p N C U 0 7 •N O N n � N Y Y E m s p O v N Optional Accessories .. DAIK►N Indoor Unit Included Part Number Description AZAI6WSCDKB DKN Residential Cloud Wi-Fi Adaptor for Single- and Multi -Zone System S21 AZAI6WSPDKC DKN Plus Interface DTST-ONE-ADA-A Daikin One+ Smart Thermostat for Ductless Products BRC944B2 Wired Remote Controller BRCW90IA08 Wired Remote Controller Cable — 25ft BRCW901AO3 Wired Remote Controller Cable — 1Oft DACA-CPI-I Inline Condensate Pump Fits inside all Daikin wall & floor mount units DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Outdoor Unit Included Part Number Descri tion DACA-WB-3 Powder -Coated Wall -Mounted Bracket KEH041A42 Drain Pan Heater RXS15 18LV KKP937A4 Drain Plug for OD Unit KPW945B4 Low Ambient Wind Baffle / Air Adjustment Grille 15/18/24 MBH Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: October 2021 Page 4 of 4 CFM ECO-FLO-EC ENERGY RECOVERY VENTILATOR CONTINENTAL FAN SUBMITTAL DATA better AIRFLOW by DESIGNTM MODEL: ECO-FLO-EC ENERGY RECOVERY VENTILATOR ECO-FLO-EC energy recovery ventilator is the most state -of -the art and efficient solution for a comfortable indoor climate and required air exchange rates for renovations and new construction. A single ECO-FLO-EC in ventilation mode can serve rooms up to 500 sq. ft. WiFi capability allows communication between several ventilators for coordinated operation. CONSTRUCTION • High efficiency ceramic heat exchanger • MERV 5 filter standard, MERV 14 optional • High quality plastic front grille with automatic shutter • Corrosion resistant outdoor hood • Telescopic duct, up to 19.75 in. Model ECO-FLO-EC Voltage (V/Hz) 100-240/50-60 Speed Setting 1 2 3 4 Power (W) 3.78 4.71 6.85 10.55 Current (A) 0.048 0.056 0.075 0.106 Airflow (cfin) - Ventilation Mode 9 18 29 50 Airflow (cfin) - Regeneration Mode 4 9 15 25 Speed (RPM) 1050 1600 2270 2930 Sound Pressure at 3 ft. (Sons) 0.7 1.5 1 3.0 4.3 Transported Air Temperature (°F) 5 to 104 Regeneration Efficiency (%) <_ 70 Regenerator Type Ceramic Filter MERV 5, MERV 14 (optional)* Ingress Protection IP24 * MERV 14 filter decreases airflow from 50 cfin to 40 cfin MOTOR • Efficient reversible 12V DC motor • Single phase, 100-240V, 50/60Hz input PROJECT ARCHITECT DATE ENGINEER SUBMITTED BY CONTRACTOR SPECIFICATION FAN NO. MODEL NO. CFM VOLTS WATTS QTY OPTIONAL EQUIPMENT r 0 N www.continentalfan.com 1 1-800-779-4021 z CFbf Buffalo, New York I Mississauga, Ontario I Dayton, Ohio � Job Name: System Reference: Date: GENERAL FEATURES • Lossnay® cross -flow energy recovery core • Minimal cross contamination between entering and leaving air streams • Stand-alone remote controller (PZ-62DR-EA) • M-NET Connectivity • External input bypass damper control • Stand alone or interlocks connects with all Mitsubishi Electric products • Four fan speeds • High efficiency DC Motor • Standard MERV 7 non -woven fabric filter, washable fiber • Optional high -efficiency MERV 14 and MERV 16 filters Specifications Unit Type Capacity Power source Power Consumption Current CFM [m3/h] System ,,. 300 [510] Voltage, Phase, Hertz 208/230V, 1-phase, 60 Hz kW 0.111 - 0.235 A 0.017 - 0.048 Starting Current A 6.1 MCA A 4.25 Maximum Overcurrent Protection (MOCP) A 15 Fan Air Volume CFM [m3/h] 75-150-225-300 [127-225-382-510] External Static pressure in.WG 0.06-0.25-0.56-1.0 Exchange Efficiency Temperature % 83-76-70-65.5 Enthalpy Cooling % 65.0-58.0- 53.5- 50.0 Enthalpy Heating % 81.5-74.0-66.5-63.0 External Finish Galvanized steel sheet External Dimensions In. [mm] 41-7/8 x 41-3/16 x 13-1/32 [1063 x 1046 x 3311 Net weight Lbs [kg] 75 [34] Energy Transfer Mechanism Lossnay® Core Heat Exchange Material Partition, spacing plate -cellulose fiber membrane Heat Exchange System Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts Blower Type 8-3/4 In. diameter centrifugal fan Motor Type EC Motor Entering Air Temperature Operation Range T [-C] 14 to 104 [-10 to 40] Sound pressure level dB(A) 18.0-22.0-31.0-37.0 Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Wired Remote Controller Lossnay® ERV Remote Controller Signal Output Terminal Duct Silencer MERV 14 Filter MERV 16 Filter MERV 7 Filter (Included) CO2 Sensor, Built -In CO2 Sensor, Wall Mount ❑ PZ-62DR-EA Control Interface ❑ PZ-4GS-E Duct Accessories ❑ PZ-200SS-E Filter ❑ PZ-50RFP-E ❑ PZ-50RFP2-E ❑ PZ-50RF9-E Remote Sensor ❑ PZ-70CSB-E ❑ PZ-70GSW-E Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 4 7/8' (124)— Air exhaust fan �M u-) -2 E A (exhaust air outlet) 0A (outside air intake) Core, o rn air filter, `° High -Efficiency filter, b - N fan, _� �o maintenance space d N $ L_ 4 7/8' (124) Lossnay core 3 1/8' (79) 1 1 in \ o M M Position where duct direction change is Possible FORM# LGH-F300RVX2-E - 202112 Position where duct direction change is Possible By-pass damper plate 1/2' (875 Ceiling suspension fixture (4-9/16' X13/16' (4-15xHlovah _3 11/32' (85) RA _ ~(return air) m Lo 1 ' T1— U lllf 1' 'I'II cc, IF I � I N CM (supply air) + o 3 11/32' (8 ) 10ion opPeninening I Air Supply fan 1 3/16' (30) 1.5X1.5ft NControl box 13 1/32' (331) (450X450) or more Maintenance cover High -Efficiency filter (sold separately) 34 15/16' attachment Position (AAA) I 1 3 1/8' (79) Air filtersCo 6 9 Q1 M r- Co a g Power supply\ cable opening UNIT SCALE -a inch(mm) N.T.S 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com C ETRs Intertek Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.