APPROVED BLD-RESUB 1-Structural Plans-7.27.2022 (2)GENERAL REQUIREMENTS REFER TO SUBSEQUENT PLAN AND DETAIL NOTES FOR VARIATIONS AND REQUIREMENTS SPECIFIC TO REFERENCED PROJECT. NOTES ON DRAWINGS TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES. DESIGN CRITERIA BUILDING CODE CONFORMANCE (MEETS OR EXCEEDS REQUIREMENTS): 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 WASHINGTON BUILDING CODE 2018 WASHINGTON RESIDENTIAL CODE DEAD LOADS: FLOOR DEAD LOAD 15 PSF INTERIOR WOOD WALL DEAD LOAD 9 PSF BRICK WALL DEAD LOAD 78 PSF CONCRETE 150 PCF LIVE LOADS: FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF FSI PIN PILES MATERIALS: BRACKET PLATES - ASTM A36 (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) PIER TUBES - ASTM A500 GRADE B OR C (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 55 KSI) EXTERNAL SLEEVE - ASTM A500 GRADE B (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 62 KSI) PIER CAP - ASTM A529 GRADE 50 (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 65 KSI) COIL ROD - ASTM A193 GRADE B7 (MIN YIELD STRESS, Fy = 105 KSI / MIN TENSILE STRESS, Fu = 125 KSI) STEEL ANGLE SHAPES - ASTM A36 (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) WELDING NOTES: CONFORM TO AWS D1.1. WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH AWS REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. CORROSION PROTECTION: SACRIFICIAL DESIGN THICKNESS - CAPACITIES INCLUDE A SCHEDULED LOSS IN STEEL THICKNESS DUE TO CORROSION FOR BLACK, UNCOATED STEEL. ANCHORS ARE DESIGNED FOR 50-YEAR SCHEDULED SACRIFICIAL THICKNESS LOSS IN ACCORDANCE WITH ICC-ES AC358. INSTALLATION: SYSTEM TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MINIMUM INSTALLATION REFUSAL REQUIREMENTS FOR PIN PILES AND MINIMUM INSTALLATION TORQUE IS TO BE DETERMINED BY THE FOLLOWING VERBIAGE/EQUATION: FSI PIN PILES (CONT.) PIN PILE SPLICING: PIN PILES ARE TO BE GRAVITY SPLICED WITH FITTING COUPLERS. BUILDING WEIGHT WILL ENSURE JOINTS DO NOT SEPARATE. TESTING & INSPECTION CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING INSTALLATION PER 2018 IBC SECTION 1810.4.12. THE SPECIAL INSPECTOR IS RESPONSIBLE FOR VERIFYING AND RECORDING THE FOLLOWING: EXPIRES: 04/04/24 • PROJECT DESCRIPTION (ADDRESS, INSTALLATION DATE, PERMIT NUMBER • PILE AND BRACKET CONFIGURATION • PART DESCRIPTION (PRODUCT MANUFACTURER, BRACKET TYPE, PIER TYPE, PIER OUTSIDE DIAMETER, PIER WALL THICKNESS) • PIER INCLINATION, LOCATION, DEPTH, AND INSTALLATION PRESSURE ACHIEVED LOAD TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM METHOD D1143 (QUICK METHOD) ON 20 PERCENT OF PIERS AND WILL BE SELECTED BY THE SPECIAL INSPECTOR. AN ALIGNMENT LOAD (AL) SHALL BE APPLIED TO THE PILE PRIOR TO SETTING THE DEFLECTION MEASURING EQUIPMENT TO ZERO OR A REFERENCE POSITION. THE AL SHALL BE NO MORE THAN 10% OF THE DESIGN LOAD. INCREMENTAL LOADING SHALL BE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE. TEST LOADING SCHEDULE DEFLECTION AL (.10 DL MAX) 0.25 DL 0.50 DL 0.75 DL 1.00 DL 1.25 DL 1.50 DL 1.25 DL 1.00 DL 0.75 DL 0.50 DL 0.25 DL HOLD TIME 0 MIN. UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE HOLD FOR CREEP TEST (SEE BELOW) UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE MAX 0.04 INCHES LOAD TESTING CREEP ACCEPTANCE CRITERIA SHALL BE NO GREATER THAN 0.04 INCHES WITHIN A 10 MINUTE PERIOD. IF MOVEMENT IS OBSERVED GREATER THAN 0.04 INCHES WITHIN THE 10 MINUTE PERIOD THE LOAD TEST SHALL BE HELD FOR AN ADDITIONAL 50 MINUTES, THE PIER IS TO BE DEEPENED AND RE -TESTED, OR THE PIER IS TO BE ABANDONED AND REPLACED WITH A NEW PIER. IF THE LOAD TEST IS TO BE HELD THE PIER MOVEMENTS SHALL BE MEASURED AT 15, 20, 30, 40, 50, AND 60 MINUTES. THE CREEP VERSUS THE LOGARITHM OF TIME SHALL BE PLOTTED. IF THE CREEP RATE IS LESS THAN 0.080 INCHES BETWEEN 6 AND 60 MINUTES, THE LOAD TEST SHALL BE CONSIDERED SUCCESSFUL. PIN PILE TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / [AREA OF HYDRAULIC RAM]. PIN PILES ARE TO BE DRIVEN TO REFUSAL. INSTALLATION REFUSAL IS CONSIDERED TO BE REACHED WHEN THE ENERGY FROM A 150 LB PNUEUMATIC HAMMER NO LONGER CARRIES A VERTICAL DISPLACEMENT OF ONE INCH MOVEMENT OBSERVED IN A ONE MINUTE TIME SPAN TO THE PILE. MINIMUM INSTALLATION DEPTH IS 10'-0"f UNO. APPROVED PLANS MUST BE NOTIFY ENGINEER IF MINIMUM INSTALLATION CONDITIONS CANNOT BE ACHIEVED. ON JOB SITE EXISTING UTILITY LINES: r CONTRACTOR TO REPAIR UTILITY LINES THAT MAY BE DAMAGED DURING INSTALLATION. City Of Edmonds Building Department Work FOUNDATION STABILIZATION Address 1005 7TH AVE S Owner--------------------TOMIK---- --------------------- Approved Date 08/05/2022 Building Official Permit Number lce'wU�Ofst 1Gi BLD2022-0582 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE RESUB Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SFA Design Group, LLL 11 P_j"d ROR`IELivermore, fCA (Seattle, WA p: (50) 91.8311 w .fadg. M CU J J CE Z_ Q Z Z E-L U � o W N 00 z Z W rn W Q U = Q woo 0 Lr) Z 0 LU O 0 Lu LL Z LU W Q GENERAL NOTES (REVISIONS 1 1 /1\ 1 07-27-22 1 PROJECT NO: M FR21-217 DESIGNED BY: MEK DRAWN BY: MEK, JAM CHECKED BY: CVR, JLD DATE: 05.05.2022 SHEET NO: S1.1 SAFEBASE 2.5 STRUCTURAL LIFTING FOAM MATERIAL PROPERTIES: • VISCOSITY OF RESIN AT 77'F: "A" 200 f 50 Cps "B" 550 t 50 Cps • SPECIFIC GRAVITY AT 25': "A" 1.24 9mI "B" 1.05 &1 • MIXING RATION, % BY VOLUME: "A" 50 "B" 50 • COLOR: "A" AMBER "B" LIGHT YELLOW • SHELF LIFE OF SYSTEM: 12 MONTHS TYPICAL REACTION PROPERTIES • CREAM TIME AT 77°F f 6 SECONDS • RISE TIME AT 77°F t 12 SECONDS • CREAM TIME AT 150'F t 2 SECONDS • RISE TIME AT 150'F t 12 SECONDS CLOSED CELL CONTENT: >90% DENSITY (FREE RISE CORE) t 2.3 — 2.5 LBS/FT^3 DENSITY (IN PLACE) f 3.0 — 5.0 LBS/FT^3 COMPRESSIVE (FREE RISE) t 35 PSI COMPRESSIVE (IN PLACE) t 60 — 75 PSI SAFEBASE STRUCTURAL LIFTING FOAMS ARE MOST OFTEN USED BENEATH EXTERIOR CONCRETE SIDEWALK AND PAVEMENT SECTIONS FOR STABILIZATION OR RELEVELING, BUT ARE ALSO UTILIZED FOR INTERIOR WORK AND OTHER SPECIALTY APPLICATIONS. SAFEBASE STRUCTURAL LIFTING FOAM FOAM IS OFTEN CONSIDERED AS AN ALTERNATIVE TO MUDJACKING OR REMOVAL AND REPLACEMENT. SETTLEMENT OF RESIDENTIAL SLABS IS TYPICALLY THE RESULT OF CONSOLIDATION OF POORLY COMPACTED FILL SOILS AROUND FOUNDATIONS AND WITHIN UTILITY TRENCHES, SOFTENING OF WEAK NATIVE SOILS AND FILL DUE TO INCREASES IN MOISTURE CONTENT, AND EROSION OR WASHOUT CONDITIONS RESULTING FROM POOR DRAINAGE. CRACKED SLABS, FAULTING BETWEEN SLAB SECTIONS, AND/OR OTHER OBVIOUS DOWNWARD VERTICAL MOVEMENT ARE TYPICALLY THE FIRST OBSERVABLE SYMPTOMS OF SETTLEMENT FROM THE SURFACE, THOUGH VOIDS MAY ALSO BE PRESENT BELOW AS RIGID SLABS CAN SPAN BETWEEN SUPPORT POINTS. WHEN VOIDS ARE PRESENT, USING INERT, HYDROPHOBIC SAFEBASE STRUCTURAL LIFTING FOAM EXPANDING FOAM ALLOWS FOR UNDERSEALING OF THE REGION, PREVENTING ANY FURTHER WASHOUT AND ACTING TO AGAIN PROVIDE UNIFORM SUPPORT TO THE BRIDGED CONCRETE. WHEN SLABS HAVE SETTLED, WITH OR WITHOUT THE PRESENCE OF VOIDS, FOAM CAN BE INJECTED TO CREATE LIFT WITHOUT ADDING SIGNIFICANT WEIGHT TO THE UNDERLYING SOIL. SAFEBASE STRUCTURAL LIFTING FOAM IS INSTALLED WITH CUSTOM—BUILT INSTALLATION RIGS AVAILABLE AS TRUCK —MOUNTED OR TRAILER UNITS. THE BASIC COMPONENTS OF THE SYSTEM INCLUDE MATERIAL STORAGE TANKS, A GENERATOR, AN AIR COMPRESSOR, PUMPS, A PROPORTIONER, AND APPLICATOR(S)/ GUN(S). THE PROPORTIONER INCLUDES A MATERIAL HEATER, PRESSURE REGULATOR, STROKE COUNTER, AND INSULATED AND HEATED HOSES. THIS ENSURES THAT THE TWO PARTS ARE DELIVERED TO THE APPLICATOR AT A CONSISTENT PRESSURE AND TEMPERATURE. SAFEBASE 2.5 STRUCTURAL LIFTING FOAM (CONT.) INSTALLATION SEQUENCE THE FOLLOWING INSTALLATION STEPS PROVIDE A BROAD OVERVIEW OF SAFEBASE 2.5 STRUCTURAL LIFTING FOAM INJECTION BENEATH A CONCRETE SLAB OR PAVEMENT. INTERMEDIATE STEPS, INSTALLATION EQUIPMENT AND TOOLS USED, AND CONSIDERATIONS FOR UNUSUAL CONDITIONS OR APPLICATIONS ARE NOT ADDRESSED. STEP 1: ACCESS/APPLICATION HOLES ARE DRILLED (9/8"0) AT STRATEGIC LOCATIONS IN THE SLAB. IN GENERAL, THE HOLES ARE SPACED 5 FEET APART AND 3 FEET FROM THE EDGES OF THE SLAB. LOCATIONS AND SPACING ARE OFTEN MODIFIED IN THE FIELD TO ACHIEVE THE DESIRED RESULT. STEP 2: INJECTION PORTS ARE PLACED TO SEAL THE HOLES. STEP 3: SAFEBASE STRUCTURAL LIFTING FOAM IS INJECTED TO FILL VOIDS AND ALLOW FOR LIFTING. LIFT MAY BE MONITORED WITH SURVEY EQUIPMENT OR STRING LINES. STEP 4: THE INJECTION PORTS ARE REMOVED AND THE HOLES ARE PATCHED WITH MORTAR MIX, NEXUSPRO SILICONE JOINT SEALANT, OR EPDXY SEALANT. EXPIRES: 04/04/24 SAFEBASE STABILIZER SYSTEM INFO PART DESCRIPTION COMMENTS MIN YIELD STRESS, Fy MIN TENSILE STRESS, F„ V ASTM A36 V /2x6x0'-6" W/ (4) /g"0 HOLES W/ WELDED WOOD BEAM 36 KSI 58 KSI TOP 11/4"0x1 1/ " IPS SCH 40 ASTM A53 PIPE CONDITION 30 KSI 48 KSI 11/40"-702" ASTM A193 GRADE B7 THREADED ROD W/ THREADED ROD 11/40"-7 ASTM A194 GRADE 2H HEX NUT 75 KSI 125 KSI HSS 4x4x3/16x0'-4" ASTM A500 GRADE B/C HD GALV PER ASTM THREADED CAP A123 W/ WELDED V3/4x4x0'-4" ASTM A36 & 11/4"0-7 ASTM 194 50 KSI 36 KSI 65 KSI 58 KSI GRADE 2H HEX NUT V1/4X6x0'-6" ASTM A36 W/ (2) HOLES W/ WELDED HSS 36 KSI 58 KSI BASE 4x4x3/16x0'-2" ASTM 500 GRADE B/C HD GALV PER ASTM A123 50 KSI 65 KSI 3/16" HIGH DENSITY POLYETHYLENE SHELL (21 "SQ BASE) LIGHTFOOT 15 PCF POLYURETHANE (F'c=470-510 PSI) 3.375 KIPS MAX BASE 10 PCF POLYURETHANE (F'c=285-310 PSI) 3.5 PCF POLYURETHANE (F'c=55-60 PSI) ASTM A500, GRADE B/C HD GALV, PER ASTM A123 MAIN TUBE HSS 31/2x31/2x11GA 50 KSI 65 KSI NOTE: INSTALL PER MFR RECOMMENDATIONS RESUB Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT sfa 5FA Design Group, LLr PortlandRORcI'Livermore, fCA (Seattle, WA p: (503) 91.8311 .—efadg.o.m U J J Z_ Q Z Z W = o Er LV N 0 Cn 0 Z zwrn O Lu < Q W r p 0 0 Lo Z 0 W o Q O o w LL z >- Ir W w CQ G GENERAL NOTES [REVISIONS 1 1/1\ I 07-27-22 1 PROJECT NO: MFR21-217 DESIGNED BY: MEK DRAWN BY: MEK, JAM CHECKED BY: CVR, JLD DATE: 05.05.2022 SHEET NO: S1.2 '4—-------------- KEY PLAN SCALE: NTS FOUNDATION(N) FLOOR STABILIZER LAYOUT PLAN NOTES: 1. REFERENCE S1.1 & S1.2 FOR GENERAL REQUIREMENTS 2• CONTRACTOR TO NOTIFY ENGINEER OF RECORD OF DISCREPANCIES BETWEEN FIELD CONDITIONS & THOSE SHOWN IN THESE DOCUMENTS PRIOR TO WORK TYP 3. INDICATES (E) CONC STEMWALL ON (E) CONC FOOTING (CONTRACTOR TO VERIFY 6"Wx2'-0"H (E) CONC STEMWALL AND 1'-0"Wx10"DP (E) CONC FOOTING MIN TYP (NOTIFY ENGINEER OF RECORD IF FIELD CONDITIONS DIFFER IN THE AREA OF WORK)) 4. � x/sx.x SECTION CUT — DETAIL NUMBER/SHEET NUMBER 5. ® INDICATES LOCATION OF SAFEBASEMENT FLOOR STABILIZER W/ LIGHTFOOT FOOTING ((8) TOTAL) MAX LOAD TO STABILIZER = 1,824 LBS 6, FLOOR STABILIZER SPACING SHALL BE AS INDICATED ON PLAN 7. REPLACE "IN —KIND" ALL (E) WOOD MEMBERS (JOISTS, PURLINS, SUBPURLINS, SHEATHING, STUDS, WALL PLATES) WHICH SHOW SIGNS OF DRY ROT OR STRUCTURAL DAMAGE 8• ALL WOOD EXPOSED TO CONCRETE, WEATHER, OR WITHIN 6" OF FINISH GRADE SHALL BE PRESSURE —TREATED 9. ALL MULTI —LAM BUILT—UP BEAMS TO HAVE (3) ROWS OF 16d NAILS AT 12" OC EACH 1 1/2" LAM 10. ALL CONSTRUCTION MATERIALS IN THESE DOCUMENTS ARE (N) UNO 11. FILTER SOCKS SHALL BE ADDED TO ANY CATCH BASINS DOWNSTREAM FROM THE CONSTRUCTION SITE PER CITY OF EDMONDS TYPICAL DETAIL ER902. 12. INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. T78'—O" 12'-8" I 7'-3" I Ln 0 I 0 110 0 I Lo EXPIRES: 04/04/24 RESUB Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PARTIAL (E) FDN/(N) FLR STABILIZER LAYOUT PLAN SCALE: 1/8"=1 ' —0" sfa 5FA Design Group, LLr PortlandR ORoI' Live rmore,'CA I Seattle, WA p: (503)91.8311 .—efMg-m U J J Z Q Z LU � cr N Er W 0 Cn 0 Z ZWo O w< Q W r p o In Z 0 Wow O o w LL z LU W Q (E) FOUNDATION/ (N) FLOOR STABILIZER LAYOUT PLAN [REVISIONS 1 1 /1\ 1 07-27-22 1 PROJECT NO: MFR21-217 DESIGNED BY: MEK DRAWN BY: MEK, JAM CHECKED BY: CVR, JLD DATE: 05.05.2022 SHEET NO: S2.1 RSA, PARTIAL (E) FOUNDATION/(N) PIER LAYOUT PLAN SCALE: '/8"=1'-0" z (E) FOUNDATION/ (N) PIN PILE LAYOUT PLAN NOTES: 6• (ZE INDICATES LOCATION OF 2%"0 PIN PILE W/ FSI FS238B FOUNDATION BRACKET PER DETAILS ON S4.1 ((22) TOTAL) 1. REFERENCE S1.1 & S1.2 FOR GENERAL REQUIREMENTS PIN PILE INSTALLATION NOTES: 2. CONTRACTOR TO NOTIFY ENGINEER OF RECORD OF DISCREPANCIES • MAX LOAD TO ANCHOR = 2,622 LBS BETWEEN FIELD CONDITIONS & THOSE SHOWN IN THESE DOCUMENTS • 2.375"0 PIPE PILE W/ 0.154" THICK WALL PRIOR TO WORK TYP • MINIMUM 10'-0" INSTALLATION DEPTH 3. INDICATES (E) BRICK WALL ON (E) CONC FOOTING (CONTRACTOR • DRIVE UNTIL LESS THAN 1 " MOVEMENT IS OBSERVED IN A 1 TO VERIFY 7"WX4'-0"H (E) BRICK WALL AND 1'-0"WX10"DP (E) MIN TIME SPAN WITH A 110LB (OR 140LB) PNEUMATIC HAMMER CONIC FOOTING MIN TYP (NOTIFY ENGINEER OF RECORD IF FIELD 7. PIN PILE SPACING SHALL BE AS INDICATED ON PLAN CONDITIONS DIFFER IN THE AREA OF WORK)) 8. CONTRACTOR TO NOTIFY ENGINEER OF RECORD IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATION BRACKETS RESUB 4. SECTION CUT - DETAIL NUMBER/SHEET NUMBER X/SX.X g. FILL ALL VISIBLE CRACKS IN THE FOUNDATION WALL WITH HYDRAULIC CEMENT OR EPDXY Jul 28 2022 1 0. U T CITY OF EDMONDS 5. INDICATES APPROXIMATE LOCATION OF SAFEBASE 2.5 1 11. RETAINING WALL ELEVATIONS PROVIDED FROM INFORMATION GATHERED DURING SITE DEVELOPMENT SERVICES DEPARTMENT STRUCTURAL LIFTING FOAM OR EQUIVALENT PER CONTRACTOR AS REQ'D. REF DETAIL 1/S4.3 VISIT DATED 7/7/2022 sfa 5FA Design Group, LLr P'im"d RORcI'Livermore,fCA (Seattle, WA p: (503) 91.8311 .—efadg.o.m U J J Z Q z z LU = o cr w N 0 U) 0 Z Zwo O wad Q wr-o oLoz W 0 o Q O p w LL z LU w Q (E) FOUNDATION/ (N) PIER LAYOUT PLAN [REVISIONS 1 i i1\ I 07-27-22 1 PROJECT NO: MFR21-217 DESIGNED BY: MEK DRAWN BY: MEK, JAM CHECKED BY: CVR, JLD DATE: 05.05.2022 SHEET NO: S2.2 1/ 4 T-/HOLES/PIER/ROD's 1/ 4 CAP R NOT SHOWN FOR CLARITY FS238B BRACKET - TOP SCALE: 1 1/2"=1 '-0" 1 S4.1 �-/HOLES/PIER/ROD's 2° I 6 S4.1 1 FS238B BRACKET - RIGHT SCALE: 11/2"=1'-O" 4 1,_2,1 4 7" m �-/HOLES 6 S4.1 I III v/ /4 TOLES/PIER/ROD's FS238B BRACKET - LEFT SCALE: 11/2"=1'-O" CONFINING RING WELDED TO ONE SIDE 1 S4.1 o �^ 11 _ CAP V/403/40'-53/4" SECTION A -A fA Ai 0 0 0 0 cn cam' c N R R On n0 p p I T �-/HOLES IZ-/PIER/SYM 4 I 6 S4.1 FS238B BRACKET - FRONT SCALE: 11/2"=1'-O" �4 1 y4„ �-/HOLE/PIER/SYM 4 6 S4.1 EXPIRES: 04/04/24 FS238B BRACKET - BACK SCALE: 11/2"=1 ' -O" 4 S4.1 (/7 /4 2 S4.1 /HOLE PIER/SYM RE UB JulA w2022 FS238B BRACKET - BOTTOM -OPMM SERVICES DEPARTMENT SCALE: 11/2"=1 ' -O" sfa 5FA Design Group, LLr Portland, ORcl'Livermore,fCA (Seattle, WA I p:(503)91.8311 www.sfadg.com CU J J Z Q z Z w CL m O Er LV 0 Cn N 0 Z zwrn O LU < Q W r p 0 0 In Z 0 o w Q O o w LL Z LU w Q BRACKET DETAILS REVISIONS /1\ 07-27-22 PROJECT NO: MFR21-217 DESIGNED BY: MEK DRAWN BY: MEK, JAM CHECKED BY: CVR, JLD DATE: 05.05.2022 SHEET NO: S4.1 (E) EXTERIOR SURFACES (SAWCUT AS REQ'D) ((E) EXTERIOR GRADE AS OCCURS) EWE DIRECT INJECTION POLYURETHANE PER PLAN TYP BRICK WALL NI I Mi I 1=1 I_ L1, 1 O O I II (E) CONC FOOTING (CHIP FLUSH II I W/ STEMWALL AS REQ'D) STEEL ANGLE LEDGER PER PLAN TYP FOUNDATION BRACKET PIN PILE PER PER PLAN TYP PLAN TYP N) PIN PILES TO (E) CONC FTG DETAIL SCALE: 1 "=1'-0" SB LF6-01009 PER GENERAL NOTES — (E) INTERIOR GRADE NOTES: 1. REF PLAN FOR LAYOUT & INSTALLATION REQ'S 2. INSTALL PER MFR RECOMMENDATIONS LF STABILIZER IN CRAWLSPACE EXPIRES: 04/04/24 (E) FLOOR SHEATHING (E) FLOOR FRAMING TYP (E) FLOOR BEAM (41/2"W MIN) SB LF6-01008 PER GENERAL NOTES W/ (4) #9X3" WOOD SCREWS SB LF6-011013 STABILIZER BASE RESUB Jul 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCALE: 1 "=1'-0" sfa 5FA Design Group, LLr PortlandRORcI'Livermore,cCA (Seattle, WA I p: (503�641�0311 www.sfatlg.com U J J Z Q Z Z LU m o Er LLI 0 U) N 0 Z Zwrn LD w Q W r p 0 0 Lo Z 0 o W Q O o w LL z LU w Q PIN PILE DETAILS REVISIONS 01 07-27-22 PROJECT NO: MFR21-217 DESIGNED BY: MEK DRAWN BY: MEK, JAM CHECKED BY: CVR, JLD DATE: 05.05.2022 SHEET NO: S4.2 %"0 HOLE DRIL FOR PRIMARY INJECTION POINT (E) BRICK WALL NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S DIRECT INJECTION VOID FILL DETAIL (E) EXTERIOR GRADE TYP (E) CONIC FOOTING SPHERE OF INFLUENCE TYP SCALE: 1 "=1'-0" EXPIRES: 04/04/24 RESUB "ca-, 5FA Design Group, 9 9 r Portland, ORLEPi ermore,'CA Seattle, WA I P:I.91941�9911 w�ne.sfatlg.com U J J Z Q Z Z LU m o Er LV 0 U) N 0 Z Z00 wrn O W Q Q W r p 0 0 Lo Z 0 o D w Q O o w LL z LU w Q DETAILS REVISIONS IAI 07-27-22 PROJECT NO: MFR21-217 DESIGNED BY: MEK DRAWN BY: MEK, JAM CHECKED BY: CVR, JLD DATE: 05.05.2022 Jul 28 2022 SHEET NO: CITY OF EDMONDS DEVELOPMENT SERVICES S4.3 DEPARTMENT