Loading...
REVIEWED BLD-BLD2022-0582+Structural_Calculations+5.6.2022_8.41.20_AM+2851868 (2)STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS PORTLAND, OR I LIVERMORE, CA I SEATTLE, WA 503.641.8311 1 www.sfadg.com 5FA Design Group, LU .�Faa ............................................... REVIEWED BY STRUCTURAL CALCULATIONS :CITY 'OFEDMONDS RECEIVED May 19 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Peerand Residence Underpinning 1005 7th Ave S, Edmonds, WA 98020 Matvey Foundation Repair, Inc. EXPIRES: 04/04/24 LIMITATIONS ENGINEER WAS RETAINED IN A LIMITED CAPACITY FOR THIS PROJECT. DESIGN IS BASED UPON INFORMATION PROVIDED BY THE CLIENT WHO IS SOLELY RESPONSIBLE FOR ACCURACY OF SAME. NO RESPONSIBILITY AND/OR LIABILITY IS ASSUMED BY, OR IS TO BE ASSIGNED TO THE ENGINEER FOR ITEMS BEYOND THAT SHOWN ON THESE SHEETS. Project No. MFR21-217 May 5, 2022 BLD2022-0582 [� 5FA Design Group, LLc ®� STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS PROJECT NO. (SHEET NO. MFR21-217 PROJECT DATE Peerand Residence Underpinning 5/5/2022 SUBJECT BY Pin Pile & Stabilizer Design Requirements MEK IStructural Narrative The structural calculations and drawings enclosed are in reference to the design of the retaining wall underpinning located in Edmonds, WA as referenced on the coversheet. The round steel tubes and retrofit brackets are used to stabilize and/or lift settling foundations. The bottom and back portion of the bracket is securely seated against the existing concrete footing. Pin Piles are driven until less then 1 inch movement is observed in a one minute time span using a 110LB (or 140LB) pneumatic hammer. The piles are required to resist vertical loading from the brick wall and concrete footing. Underpinning the retaining wall will remove lateral resistance provided by soil friction acting on the concrete foundation. By Inspection, lateral resistance will be provided by soil friction acting on the unpiered portions of the concrete footing and passive pressure acting on the buried footings perpendicular to the piered gridlines. The structural calculations and drawings enclosed support the use of SafeBase Crawlspace Stabilizer for mitigation of observed structural settlements, and support of the vertical loads tributary to it, at a residential property located in Edmonds, WA as referenced on the coversheet. Crawlspace Stabilizer consist of a 3.5" square steel tube attached to a plate by a 1.25" diameter adjustable threaded rod. This plate is attached to the bottom side of a supporting beam with (4) wood screws. The steel pipe sits in a pre -fabricated base plate that bears on a pre -fabricated Lightfoot Stabilizer base filled with injected polyurethane foam. There is no ICC-ES report currently approved for underpinning systems within Seismic Design Category D or higher, thus the entire underpinning system has been reviewed and analyzed and is therefore a fully engineered system complying with all current codes and stamped by a licensed design professional. Deep foundation guidelines, load combinations, special inspection and testing requirements per IBC 2018 have been included. Axial and bending capacities of the external sleeve, analysis of the retrofit foundation bracket, design reductions, and corrosion considerations have been incorporated in all required calculations per AISC 360-10. Concrete foundation span capacities have been analyzed per AC1318-14. Bracket fabrication welding has been performed. conforming to AWS D1.1 performed by CWB qualified welders certified to CSA Standard W47.1 in Division 2. (General Building Department City of Edmonds Building Code Conformance (Meets Or Exceeds Requirements) 2018 International Building Code (IBC) 2018 International Residential Code (IRC) 2018 Washington Building Code 2018 Washington Residential Code (Dead Loads Floor Dead Load Interior Wall Dead Load Brick Wall Dead Load Concrete 15.0 psf 9.0 psf 78.0 psf 150.0 pcf I Live Loads Floor Live Load (Residential) 40.0 psf [� 5FA Design Group, LLC PROJECT NO. SHEET NO. �] STRUCTURAL I GEOTECEWICAL I SPECIAL INSPECTIONS IMFR21 -217 PROJECT DATE Peerand 5/5/2022 SUBJECT BY Proiect Lavout MEK Project Layout (See S2.1 for Enlarged Plan) _ �78'-O" 12'-8" 1 7'-3" (E)OAB GRADE ON L - -J, --- 5' ~r POST & (E) BEAM FTG TYR ABOVE TYR I ; EQIEQI EQ I EQ EQ EQ EQ IEQ r, o t: I (E) CCNC SLAB I`I ,.? ON GRADE Lo I,L — — — -J (E) CRAWL - - - " SPACE TYR 'COLUMN 'PIER 5FA Design Group, LLC PROJECT NO. SHEET NO. STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS IMFR21-217 PROJECT DATE Peerand Residence Underpinning 5/5/2022 SUBJECT BY Desiqn Loads MEK (Worst Case Vertical Design Loads (Retaining Wall) Tributary Width To Pier = = 6.00 ft Load Type Design Load Tributary Length Line Load Dead Load 2.622 kips Floor Live Load 0.000 kips Brick WaIIDL = (78 psf) (48.00 in) = 312 plf Roof Snow Load 0.000 kips FootingDL _ (150 pcf) (10.00 in) (12.00 in) = 125 plf Controlling ASD Load Combination: D+L Max Vertical Load to Worst Case Pier 2.622 kips 5FA Design Group, LLC PROJECT NO. SHEET NO. STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS IMFR21-217 PROJECT DATE Peerand 5/5/2022 SUBJECT BY Foundation Su000rtworks 2.375" in O Pin Pile Svstem MEK Design Input Pin Pile System Designation = X-Strong, Sch 80 Vertical Load to Pier, PTL = 2.622 kips < 4 kips, OK Minimum Installation Depth, L = 10.000 ft Unbraced Length, I = 0.500 ft Eccentricity, e = 4.250 in Friction Factor of Safety, FS = 2 Design Load (Vertical), PDL = 2.622 kips Design Moment, MomentPlerDL = 11.144 kip -in (Sleeve Property Input Sleeve Length = 0.000 in rYCAVATION Design Sleeve OD = 2.822 in Design Wall Thickness = 0.176 in r = 0.937 in _ A = 1.465 in S = 0.912 in3 Note: Sleeve reduces bending stress on main Z = 0.000 in — pier from eccentricty I = 1.287 in° V2 E = 29000 ksi Fy = 50 ksi 4 CL/PILE/ REACTION I (E) PILE CAP -0 (E) G I- STEMWALL AND FOOTING O I _II — —I FOUNDATION BRACKET III— PNEUMATICALLY DRIVEN III PILE & EXTERNAL Pier Property Input �� .I I II-' SLEEVE F Design Tube OD = 2.319 in =I --I Design Wall Thickness = 0.190 in I I k = 2.10 r = 0.756 in IV A = 1.272 in Note: Design thickness of pier and sleeve c = 1.160 in based on 93% of nominal thickness per AISC S = 0.3 in } and the ICC-ES AC358 based on a corrosion Z = 0.865 65 in3 loss rate of 50 years for zinc -coated steel REACTION AT LOAD I = 0.727 in' BEARING STRATUM E = 29000 ksi Note: Section above is a general representation of pin pile system, Fy = 60 ksi refer to plan for layout and project specific details. Pier Output Per AISC 360-10 Doubly and Singly Symmetric Members Subject To Flexure and Axial Force kl/r = 16.67 OK, <200 §E2 Note: Flexural design capacity Fe = 1029.434 ksi §(E3-4) based on combined plastic section 4.71 *(E/F )'5 = 103.55 §E3 modulous of pier and sleeve Fir = 58.554 ksi §(E3-2 & E3-3) Pn = 74.5 kips §(E3-1) Safety Factor for Compression, Dc = 1.67 Allowable Axial Compressive Strength, Pn/0, = 44.6 kips §E1 Actual Axial Compressive Demand, Pr = 2.622 kips D/tpief = 12.2 OK, <.45E/Fy §F8 Mn = 51.9 kip -in §(F8-1) Safety Factor for Flexure, ob = 1.67 Allowable Flexural Strength, Mn/f2b = 31.1 kip -in §F1 Actual Flexural Demand, Mr = 11.1 kip -in Combined Axial & Flexure Check = 0.39 OK §(H1-1a & 1b) IResults Max Load To Pier = Design Load = 2622 lb 2.375" Diameter Pipe Pier with 0.154" Thick Wall Minimum 10'-0" Installation Depth And Minimum 900 psi Installation Pressure Drive Until Less Than 1" Movement Is Observed In a 1 min Time Span With a 110LB (Or 140LB) Pneumatic Hammer 5FA Design Group, LLC PROJECT NO. SHEET NO. STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS IMFR21-217 PROJECT DATE Peerand 5/5/2022 SUBJECT BY Foundation Swoortworks FS238B Bracket MEK Capacity of 5/8"0 GR137 (125ksi) Threaded Rod 11=11 D = 0.625 in Ft = 125 ksi At = 0.226 in Capacity = 28.250 kips Block Shear at %" Plate O and i0 to O TBs = 0.3(58)(%)(6)+0.5(58)(%)(1) = 50.025 kips Capacity of 3/a" Plate At = 1.781 in Ft = 21.600 ksi T = 38.475 kips I = 0.004 in A = 0.188 in r = 0.144 in k = 1.00 I = 6.563 in �/4 FATE kI/r = 46.0 Fa = 20.350 ksi 3/ " tAT E S = 0.431 in' 8 Fb = 27.000 ksi RmAx = 7.714 kips t Limiting System Factor Fv = 14.400 ksi VALLow = 29.025 kips Results C Capacity of System (2 Sides) = 7.71(2)=15.42kips (Bracket Only) 7 LATE 02 5FA Design Group, LLC STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS PROJECT NO. ISHEET NO. M FR21-217 PROJECT DATE Peerand Residence Underpinning 5/5/2022 SUBJECT BY Desiqn Loads MEK (Worst Case Vertical Design Loads (Floor Stabilizer) Tributary Width To Pier = = 6.00 ft Load Type Design Load Tributary Length Line Load Dead Load 0.684 kips 1stFloorDL _ (15 psf) (4.75 ft) = 71 plf Floor Live Load 1.140 kips 1stFloor-L _ (40 psf) (4.75 ft) = 190 plf Roof Snow Load 0.000 kips InteriorWallDL _ (9 psf) (4.75 ft) = 43 plf Controlling ASD Load Combination: D+L Max Vertical Load to Worst Case Pier 1.824 kips SFA Design Group, LLC PROJECT NO. SHEET NO. STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS IMFR21-217 PROJECT DATE Peerand Residence Underpinning 5/5/2022 SUBJECT BY Safebase Crawlspace Stabilizer Svstem MEK SB LF6-01009 PER GENERAL NOTES (E) INTERIOR GRADE (E) FLOOR SHEATHING (E) FLOOR FRAMING TYP (E) FLOOR BEAM (41/2"W M'N) SB LFO-01008 PER GENERAL NOTES W/ (4) bx3° WOOD SCREWS SB LFO-011013 STABILIZER BASE Note: Section above is a general representation of Stabilizer system, refer to plan for layout and project specific details. (Tube Properties Safebase Crawlspace Stabilizer System = Pmax = Maximum Tube Unbraced Length, dt = Maximum Threaded Rod Unbraced Length, dtr = Eccentricity, emax = Moment = Design Tube = Design Wall Thickness = k= r= A= c= S= E_ Fy = SB350 1.824 3.000 3.000 1.000 1.824 3.500 0.1196 1.00 1.380 1.261 1.750 1.373 2.402 29000 50 kips ft in in in -kips in in in in in in' in ksi ksi Tube Output kl/r = 26.09 Cc = 107.00 F'e = 219.35 ksi Fa = 27.62 ksi fa = 1.45 ksi Fb = 33.00 ksi fb = 1.33 ksi Cm = 1.00 fa/Fa = 0.05 Threaded Rod Properties Threaded Rod Output Bearing Capacity of LightFoot Base l Results Eq H1-1 NA Eq H1-2 NA Eq 1-11-3 0.09 Threaded Rod Dia. = 1.250 in k = 1.00 r = 0.313 in A = 1.227 in c = 0.625 in S = 0.192 in 1 = 0.120 in E = 29000 ksi Fy = 70 ksi kl/r = 9.60 Cc = 90.43 F'e = 1619.74 ksi Fa = 40.79 ksi fa = 1.49 ksi Fb = 46.20 ksi fb = 9.51 ksi Cm = 1.00 fa/Fa = 0.04 Eq H1-1 NA Eq H1-2 NA Eq 1-11-3 0.24 Footing Depth = 5.50 in Footing Width = 18 in Footing Length = 18 in Soil Bearing Capacity = 1500 psf Capacity = 3.375 k Slenderness OK Eq 1-11-3 may be used Pier OK Slenderness OK Eq 1-11-3 may be used 101'TXilN OK MAX LOAD TO STABILIZER = 1824LB 3.5 IN DIAMETER SAFEBASE TUBE WITH 0.1196 IN. THICK WALL AND MAX HEIGHT OF 3FT 1.25 IN DIAMETER SOLID THREADED ROD WITH MAX HEIGHT OF 3 IN 18 IN SQR SAFEBASE LIGHT FOOT STABILIZER BASE EMBED THREADED ROD A MINIMUM OF 3/4 IN INTO CONFINING RING AND THREADED INSERT Project Title: Engineer: Project ID: Project Descr: Steel Beam Project File: Calcs.ec6 DESCRIPTION: Steel Angle Calcs CODE REFERENCES Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis Method Allowable Strength Design Fy : Steel Yield : 36.0 ksi Beam Bracing: Completely Unbraced E: Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending Vertical Leg Up D(o_s740) D 0.4370 i L6x6x3/S Span i Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.4370 k/ft, Tributary Width = 1.0 ft Point Load : D = 0.8740 k @ 1.50 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.273 : 1 Maximum Shear Stress Ratio = 0.053 :1 Section used for this span L6x6x3/8 Section used for this span L6x6x3/8 Ma: Applied 1.819 k-ft Va : Applied 1.552 k Mn / Omega: Allowable 6.670 k-ft Vn/Omega : Allowable 29.102 k Load Combination D Only Load Combination D Only Location of maximum on span 0.000 ft Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection 0.000 in Ratio = 0 <600 Max Upward Transient Deflection 0.000 in Ratio = 0 <600 Max Downward Total Deflection 0.005 in Ratio = 7346 —600 Span: 1 : D Only Max Upward Total Deflection 0.000 in Ratio = 0 <600 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span D Only 1 0.0049 1.500 0.0000 0.000 Vertical Reactions Support notation : Far left is #' Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.552 Overall MINimum 0.931 D Only 1.552 +0.60D 0.931