Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED RESUB 1 BLD2022-1186+Manufacturer_Specifications_and_Installation_Instructions+9.14.2022_3.49.43_PM+3109115
Job Name: System Reference: Date: BLD2022-1186 REVIEWED BY CITY OF EDMONDS FEATURES • Variable speed INVERTER -driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 54 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection RESUB Sep 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 36,400 // 36,400 // 36,400 Rated Capacity BTU/H 35,400 // 34,900 // 34,400 Minimum Capacity BTU/H 11,700 // 11,500 // 11,300 Maximum Power Input W 3,960 // 3,960 // 3,960 Rated Power Input W 3,760 // 3,850 // 3,940 Power Factor (208V, 230V) % 99.0, 99.0 // 99.0, 99.0 // 99.0, 99.0 Heating at 47°F2 (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 43,000 // 43,000 // 43,000 Rated Capacity BTU/H 36,000 // 35,200 // 3 Minimum Capacity BTU/H 18,300 // 18,800 // 1 Maximum Power Input W 4,020 // 4,020 // 4,00 Rated Power Input W 3,020 // 3,060 // 3,1CO Power Factor (208V, 230V) % 98.7, 98.7 H 98.8, 98.8 // 98.8, 8.8 Heating at 17°F3 (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 26,600 // 26,600 // 26 Rated Capacity BTU/H 22,400 // 22,400 // ,4 Maximum Power Input W 3,440 // 3,490 // 3,540 Rated Power Input W 2,300 // 2,470 // 2,640 Heating at 5°F4 (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 24,000 // 24,000 // 24,000 Maximum Power Input W 3,320 // 3,280 // 3,240 Efficiency (Non -Ducted // Mix // Ducted) SEER 19.2 //17.6 //16.0 EER' 9.41 // 9.07 // 8.73 HSPF (IV) 11.0 // 10.4 // 9.8 COP at 47°F2 3.5 // 3.37 // 3.25 COP at 17°F at Maximum Capacity3 2.27 // 2.24 // 2.2 COP at 5°F at Maximum Capacity' 2.12 // 2.14 // 2.17 ENERGY STAR® Certified No // No // No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size A 25 Recommended Wire Size AWG 14 Minimum Circuit Ampacity A 23.1 Maximum Overcurrent Protection A 25 Fan Motor Full Load Amperage A 2.43 Outdoor unit Airflow Rate (Cooling / Heating) CFM 2,287 / 2,382 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling' dB(A) 54 Sound Pressure Level, Heating' dB(A) 56 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB220FQGMC Compressor Rated Load Amps A 12 Compressor Locked Rotor Amps A 13.7 Compressor Oil Type // Charge oz. FV50S // 23.7 Base Pan Heater Optional Unit Dimensions W: In. [mm] 37-13/32 [950] D: In. [mm] 13 [330] H: In. [mm] 31-11/32 [796] Package Dimensions W: In. [mm] 40-15/16 [1,040] D: In. [mm] 17-11/16 [450] H: In. [mm] 40-11/16 [1,033] Unit Weight Lbs.[kg] 139 [63] Package Weight Lbs.[kg] 159 [72] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum'") °FDB 115 / 14 Cooling Thermal Lock -out / Re -start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / 5 Heating Thermal Lock -out / Re -start Temperatures °FDB 1.415 Refrigerant Charge Lbs, oz 6.0, 13.0 Chargeless Piping Length Ft. [m] 98.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 'A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Number of Connected IDU 4 Indoor unit connection Minimum Number of Connected IDU 2 12,000 Minimum connected capacity BTU/H 42,000 Maximum connected capacity BTU/H Liquid Pipe Size O.D. (Flared) In.[mm] A,B,C,D: 1/4 [A,B,C,D: 6.35] In.[mm] A: 1/2; B,C,D: 3/8 [A: 12.72: B,C,D: 9.52] Gas Pipe Size O.D. (Flared) Ft. [m] 230 [70] Total Piping Length Ft. [m] 49 [15] Piping Maximum Height Difference, ODU above IDU Ft. [m] 49 [15] RE Maximum Height Difference, ODU below IDU Ft. [m] 82 [25] 0 Farthest Piping Length from ODU to IDU 70 Maximum Number of Bends for IDU NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB CITY OF EDMONDS (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) 31-leating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB °F 70 DB, 60 WB // 17 DB, 15 WB DEVELOPMENT SERVICES DEPARTMENT Conditions 41-leating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. I5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Refrigeration Ball Valve - 1/2" Refrigeration Ball Valve - 1/4" ❑ BV12FFSI2 ❑ BV14FFSI2 Ball Valve Refrigeration Ball Valve - 3/8" ❑ BV38FFSI2 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162 - 0 Drain Socket Drain Socket ❑ PAC -SG Hail Guards Hail Guard ❑ HG-A9 M-NET Converter M-NET Converter ❑ PAC-IFO 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ 5144_ CITY OF EDMONDS 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW144-250 DEPARTMENT 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW164-50 Condensing Unit Mounting Pad: 16" x 36" x 3" ❑ ULTRILITE1 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Optional Defrost Heater Optional Defrost Heater ❑ PAC-645BH-E Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port Adapter Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Single Fan Stand ❑ QSMS1801 M 24" Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SIB 1.FREE SPACE 3-15/16' or more 2.SERVICE SPACE 3-15/16' or more FORM# MXZ-4C36NA3 - 202206 0 SERVICE SPACE E 0 0 77777 13-25/32' or more (Foundation Bolt M10) Unit: inch (mm) RESUB Sep 15 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LIO l Uni) D GAS f LIU 1 Unit C r LIO 1/4'(06.35)FLARE GAS ( GAS 3/8109.52)FLARE LIO l Unit B J GAS f LIO t Unit A — LIO 1/4'(06.35)FLARE GAS f GAS 1/2'(012.7)FLARE 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvae.com aONus Intertek Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.