WSEC ENERGY CODE
CALCULATIONS
2015 IBC
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH— ARCHITECTS. COM
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
Gary Nash @ Nash & Asso Architects
2903 (425) 242-7489
gary@Nash-Architects.com
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure, the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative
All Climate Zones
R-Value
U-Factor'
Fenestration U-Factor
n/a
0.30
Skylight U-Factor
n/a
0.50
Glazed Fenestration SHGC
n/a
n/a
Ceilingk
490
0.026
Wood Frame Wall9,m,"
21 int
0.056
Mass Wall R-Value'
21/21
0.056
Floor
30
0.029
Below Grade Wall-m
10/15/21 int + TB
0.042
Slab R-Value & Depth
10, 2 ft
n/a
"Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Date
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve
the following minimum number of credits:
1. Small Dwelling Unit: 1.5 credits
❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500
square feet.
E2. Medium Dwelling Unit: 3.5 credits
All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall
require 2.5 credits.
❑3. Large Dwelling Unit: 4.5 credits
Dwelling units exceeding 5000 square feet of conditioned floor area.
4. Additions less than 500 square feet: .5 credits
Table R406.2 Summary
Option Description
Credit(s)
1a
Efficient Building Envelope 1a
0.5
1 b
Efficient Building Envelope lb
1.0
1c
Efficient Building Envelope 1c
2.0
1d
Efficient Building Envelope 1d
0.5
2a
Air Leakage Control and Efficient Ventilation 2a
0.5
2b
Air Leakage Control and Efficient Ventilation 2b
1.0
2c
Air Leakage Control and Efficient Ventilation 2c
1.5
3a
High Efficiency HVAC 3a
1.0
3b
High Efficiency HVAC 3b
1.0
3c
High Efficiency HVAC 3c
1.5
3d
High Efficiency HVAC 3d
1.0
4
High Efficiency HVAC Distribution System
1.0
5a
Efficient Water Heating 5a
0.5
5b
Efficient Water Heating 5b
1.0
5c
Efficient Water Heating 5c
1.5
5d
Efficient Water Heating 5d
0.5
6
Renewable Electric Energy
0.5
Total Credits
*Please refer to Table R406.2 for complete option descriptions
--3
ILI
El
El
Ca
1.0
C1
1.0
�1
0.5
1❑
L- I
1.0
!- .1
j�
0.0
3.50
Window, Skylight and Door Schedule
P";rr.f !"fol"'f mContact Information
Gary Nash a Nash & Asso Architects
ff`2803 (425)242-7489
-- gary�Nash-Archileds.com -
Width Height
Ref U-factor Ot. Feet "ch Feet Inch
Area UA
Exempt Swinging Door (24 sq, ft. max) 10AS 1 3 18 240 11 76
Exempt Glazed Fenestration (15 sq. ft max.) 1 10.30 11 13 15 15.01 4.50
Vertical Fenestration (Windows and doors)
Component
Descnpliorn Ref U-factor
Door
0.49
Single -Hung
D.30
Slider
0-30
Slider
0.30
Patio Sliding Door
0.30
Slider
0.30
Fixed
0-30
Single-HunR
0.30
Fixed
0.30
Awning
0.30
Foxed
0.30
Single -Hung
0.30
Slider
0.30
Slider
0.30
Single -Hung
0.30
Fixed
0.30
Slider
0.30
Fixed
0-30
Fixed
0.30
Fixed
0,30
Single -Hung
0-30
Slider
0.30
Foxed
0.30
Slider
0.30
Width Height
at Feet "`h Feet �hch
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
Area UA
529 B 162 31
0.31
Overhead Glazing (Skylights)
Component Width Height
Description Ref U-factor at Feet 'Inch Fee! Inch Area UA
0.0 0-00
0-0 0-00
00 0-00
00 000
0.0 0.00
0,0 0-00
Sum of Overhead Glazing Area and UA 0.0 0-00
Overhead Glazing Area Weighted U = UA/Area 0.00
Total Sum of Fenestration Area and UA (for heating system sizing calculations) F568. BF 178-57
Simple Heating System Size: Washington State
Th is heating system sizin g calc I r is based an the Prescriptive Re ui ements of the 2015 Wash inqtQf) State E nergy Code nd ACCA
Manuals J and S. This I I r will calculate healing loads only. A CA procedures for sizing cooling stems should be used to determine cooligg
loads.
The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0-30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC.
Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension
Program at (360) 956-2042 for assistance.
Prolne Information contact mtormanon
Gary Nash @ Nash & Asso Architects
2903 (425)242-7489
gary@Nash-Architects.com
Heating Syster'I-Tyt2L. (j) All Other Systems O Heat Pump
To see detailed instructions for each section, place your cursor on the word "Instructions".
Design Temperature_
Instructions Design Temperature Difference (AT) 49
Snohomish
j_ _ 1 AT =Indoor (70 degrees) -Outdoor Design Temp
EE
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)
Average Ceiling Height
Instructions Average Ceiling Height (ft)
Glazing and Doors
Instructions
Skylights
Instructions
Insulation
Attic
Instructions 1 R-49
Single Rafter or Joist Vaulted Ceilings
Instructions Feat R_Value
Above Grade Walls (see Figure 1)
Instructions I R-21 Intermediate
Floors
Instructions
R-30
Below Grade Walls (see Figure 1)
Instructions Select R-value
Slab Below Grade (see Figure 1)
Instructions
Select conditioning
Slab on Grade (see Figure v
Instructions Select R-Value
Location of Ducts
Instructions
Unconditioned Space
Figure 1.
1u�ro Gr.,ao
2.903
Conditioned Volume
8.5
24,676
U-Factor
X Area =
UA
0.30
E 569
170.64
U-Factor
X Area =
UA
0.50
---
U-Factor
X =
UA
0.026
_Area
` 1.774
46.12
U-Factor
X Area
UA
No selection
U-Factor
X Area
UA
0.056
�_ 2,782
155.78
U-Factor
X Area
UA
0.029
^ 1.774
51 45
U-Factor
X Area
UA
No selection
F-Factor
X Lenyt#I
UA
No selection
�
---
F-Factor
X Len th
UA
No selection
Duct Leakage Coefficient
1.10
Sum of UA
423.99
Envelope Heat Load
20,776
Btu / Hour
Sum of UA X dT
Air Leakage Heat Load
13,058
Btu/Hour
VolumeX 0.6XATX.016
Building Design Heat Load
33,834
Btu / Hour
Air Leakage + Envelope Heat Loss
Building and Duct Heat Load
37,217
Btu / Hour
Ducts in unconditioned space: Sum of Building Heat Loss X
1. 10
Ducts in conditioned space: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output
52,104
Btu / Hour
Building and Duct Heat Loss X 1,40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07101113)