REVIEWED BLD BLD2021-0070+WSEC+1.19.2021_2.45.09_PM+1996443.,.,.,.,.,.,.,.,.....,.,.,.,.,.,.,............ 7=RECEIVED: REVIEWED NASH & ASSOCIATES Jan 21 2021 BY CITY OFEDMONDS CITY OF EDMONDS ARCHITECTS DEVELOPMENT SERVICES DEPARTMENT BUILDING DEPARTMENT BLD2021-0070 WSEC ENERGY CODE CALCULATIONS 2015 IBC 8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117 WWW. NASH— ARCHITECTS. COM Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information Gary Nash @ Nash & Asso Architects 2903 (425) 242-7489 gary@Nash-Architects.com This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones R-Value U-Factor' Fenestration U-Factor n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGC n/a n/a Ceilingk 490 0.026 Wood Frame Wall9,m," 21 int 0.056 Mass Wall R-Value' 21/21 0.056 Floor 30 0.029 Below Grade Wall-m 10/15/21 int + TB 0.042 Slab R-Value & Depth 10, 2 ft n/a "Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Date Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. E2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 1 b Efficient Building Envelope lb 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions --3 ILI El El Ca 1.0 C1 1.0 �1 0.5 1❑ L- I 1.0 !- .1 j� 0.0 3.50 Window, Skylight and Door Schedule P";rr.f !"fol"'f mContact Information Gary Nash a Nash & Asso Architects ff`2803 (425)242-7489 -- gary�Nash-Archileds.com - Width Height Ref U-factor Ot. Feet "ch Feet Inch Area UA Exempt Swinging Door (24 sq, ft. max) 10AS 1 3 18 240 11 76 Exempt Glazed Fenestration (15 sq. ft max.) 1 10.30 11 13 15 15.01 4.50 Vertical Fenestration (Windows and doors) Component Descnpliorn Ref U-factor Door 0.49 Single -Hung D.30 Slider 0-30 Slider 0.30 Patio Sliding Door 0.30 Slider 0.30 Fixed 0-30 Single-HunR 0.30 Fixed 0.30 Awning 0.30 Foxed 0.30 Single -Hung 0.30 Slider 0.30 Slider 0.30 Single -Hung 0.30 Fixed 0.30 Slider 0.30 Fixed 0-30 Fixed 0.30 Fixed 0,30 Single -Hung 0-30 Slider 0.30 Foxed 0.30 Slider 0.30 Width Height at Feet "`h Feet �hch Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Area UA 529 B 162 31 0.31 Overhead Glazing (Skylights) Component Width Height Description Ref U-factor at Feet 'Inch Fee! Inch Area UA 0.0 0-00 0-0 0-00 00 0-00 00 000 0.0 0.00 0,0 0-00 Sum of Overhead Glazing Area and UA 0.0 0-00 Overhead Glazing Area Weighted U = UA/Area 0.00 Total Sum of Fenestration Area and UA (for heating system sizing calculations) F568. BF 178-57 Simple Heating System Size: Washington State Th is heating system sizin g calc I r is based an the Prescriptive Re ui ements of the 2015 Wash inqtQf) State E nergy Code nd ACCA Manuals J and S. This I I r will calculate healing loads only. A CA procedures for sizing cooling stems should be used to determine cooligg loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0-30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Prolne Information contact mtormanon Gary Nash @ Nash & Asso Architects 2903 (425)242-7489 gary@Nash-Architects.com Heating Syster'I-Tyt2L. (j) All Other Systems O Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature_ Instructions Design Temperature Difference (AT) 49 Snohomish j_ _ 1 AT =Indoor (70 degrees) -Outdoor Design Temp EE Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions Skylights Instructions Insulation Attic Instructions 1 R-49 Single Rafter or Joist Vaulted Ceilings Instructions Feat R_Value Above Grade Walls (see Figure 1) Instructions I R-21 Intermediate Floors Instructions R-30 Below Grade Walls (see Figure 1) Instructions Select R-value Slab Below Grade (see Figure 1) Instructions Select conditioning Slab on Grade (see Figure v Instructions Select R-Value Location of Ducts Instructions Unconditioned Space Figure 1. 1u�ro Gr.,ao 2.903 Conditioned Volume 8.5 24,676 U-Factor X Area = UA 0.30 E 569 170.64 U-Factor X Area = UA 0.50 --- U-Factor X = UA 0.026 _Area ` 1.774 46.12 U-Factor X Area UA No selection U-Factor X Area UA 0.056 �_ 2,782 155.78 U-Factor X Area UA 0.029 ^ 1.774 51 45 U-Factor X Area UA No selection F-Factor X Lenyt#I UA No selection � --- F-Factor X Len th UA No selection Duct Leakage Coefficient 1.10 Sum of UA 423.99 Envelope Heat Load 20,776 Btu / Hour Sum of UA X dT Air Leakage Heat Load 13,058 Btu/Hour VolumeX 0.6XATX.016 Building Design Heat Load 33,834 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 37,217 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1. 10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 52,104 Btu / Hour Building and Duct Heat Loss X 1,40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113)