Loading...
REV 1 REVIEWED-BLD2021-0776+Calculations+3.29.2022_10.12.24_AM+2767254aFORTE®M PASSED REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT MEMBER REPORT Roof, Bl 1 piece(s) 5 1/4" x 16" 2.2E Parallam® PSL Overall Length: 28' 28' 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 6714 @ 2" 7442 (3.50") Passed (90%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 5935 @ 1' 7 1/2" 18676 Passed (32%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 45887 @ 14' 60297 Passed (76%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl.(in) 0.981 @ 14' 1.383 Passed (L/338) 1.0 D + 1.0 S (All Spans) Total Load Defl.(in) 1.661 @ 14' 1.844 Passed (L/200) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Stud wall - HF 3.50" 3.50" 3.16" 2747 3967 6714 Blocking 2 - Stud wall - HF 3.50" 3.50" 1 3.16" 2747 3967 6714 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the Pull load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 28' o/c Bottom Edge (Lu) 28' o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 28' N/A 26.3 1 - Uniform (PSF) 0 to 28' (Front) 11' 4" 15.0 25.0 Roof Load REVISION Mar 29 2022 0 System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : Aso Member Pitch : 0/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Nicholas Carter Bykonen Carter Quinn (206) 264-7784 nvc@bcq-se.com MAL 1/24/2022 4:57:20 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Cooper Residence Page 1 / 1