REV 1 REVIEWED-BLD2021-0776+Calculations+3.29.2022_10.12.24_AM+2767254aFORTE®M
PASSED
REVIEWED
BY
CITY OF EDMONDS
BUILDING DEPARTMENT
MEMBER REPORT
Roof, Bl
1 piece(s) 5 1/4" x 16" 2.2E Parallam® PSL
Overall Length: 28'
28'
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
6714 @ 2"
7442 (3.50")
Passed (90%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
5935 @ 1' 7 1/2"
18676
Passed (32%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
45887 @ 14'
60297
Passed (76%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl.(in)
0.981 @ 14'
1.383
Passed (L/338)
1.0 D + 1.0 S (All Spans)
Total Load Defl.(in)
1.661 @ 14'
1.844
Passed (L/200)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/240) and TL (L/180).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Stud wall - HF
3.50"
3.50"
3.16"
2747
3967
6714
Blocking
2 - Stud wall - HF
3.50"
3.50"
1 3.16"
2747
3967
6714
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the Pull load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
28' o/c
Bottom Edge (Lu)
28' o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 28'
N/A
26.3
1 - Uniform (PSF)
0 to 28' (Front)
11' 4"
15.0
25.0
Roof Load
REVISION
Mar 29 2022
0
System : Roof
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : Aso
Member Pitch : 0/12
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator
Job Notes
Nicholas Carter
Bykonen Carter Quinn
(206) 264-7784
nvc@bcq-se.com
MAL
1/24/2022 4:57:20 PM UTC
ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: Cooper Residence
Page 1 / 1