Loading...
REV 1 REVIEWED-BLD2021-0776+Calculations+3.29.2022_10.12.24_AM+2767255REVIEWED REVISION BYKONEN BY - Mar 29 2022 CARTER CITY OF EDMONDS € CITY DEVELOPMENTS RVI DEVELOPMENT SERVICES DEPARTMENT QUINN .,.,.,.,.BUILDING DEPARTMENT . STRUCTURAL ENGINEERING STRUCTURAL CALCULATIONS Cooper Covered Deck 918 Spruce Street Edmonds WA 98020 May 18t", 2021 ► 2033 Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.BCQ-SE.com PROPOSED CANOPY FRAMING SCALE: -1)) - 1 $ -0 4 - u MEMBER EPO T PASSED v=eop Level, Eidge­�13eai 1 piece(s) 3 1/8" x 10 1/2" 24F-V4 DF Glulam Overall Length: 16' 7" 16' ® Q All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design'; Results Actual 0 Location Allowed ' Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2719 @ 2" 4648 (3.50") Passed (59%) -- 1.0 D + 1.0 S (All Spans) Shear (Ibs) 2337 @ 1' 2" 6666 Passed (35%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 10826 @ 8' 3 1/2" 13207 Passed (82%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.578 @ 8' 3 1/2" 0.813 Passed (L/337) -- 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.948 @ 8' 3 1/Z" 1.083I Passed (L/206) -- 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length toads to Supports (Ibs) Accessories Total Available ; Required Dead Snow Total 1 - Stud wall - SPF 3.50" 3.50" 2.05" 1061 1658 2719 Blocking 2 - Stud wall - SPF 3.50" 3.50" 2.05" 1061 1658 2719 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. LateralBracing Bracing intervals Comments Top Edge (Lu) 16' 7" o/c Bottom Edge (Lu) 16' 7" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Snow' (1.15) Comments 0 - Self Weight (PLF) 0 to 16' 7" N/A 8.0 - 1 - Uniform (PSF) 0 to 16' 7" (Front) 8' 15.0 25.0 Default Load System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-Iibrary. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jeffrey Kranz Bykonen Carter Quinn (206) 264-7784 jk@bcq-se.com 5/17/2021 3:44:12 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Cooper Covered Deck Pagel/1 MEMBER E E OT PASSED Level, Header 1 piece(s) 3 1/8" x 9" 24F-V4 DF Glulam Overall Length: 10' 7" 10, `r 4 4, All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 3000 @ 2" 4430 (3.50") Passed (68%) -- 1.0 D + 1.0 S (All Spans) Shear (Ibs) 2409 @ 1' 1/2" 5714 Passed (42%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 7444 @ 5' 3 1/2" 9703 Passed (77%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.254 @ 5' 3 1/2" 0.342 Passed (L/484) -- 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.412 @ 5' 3 1/2" 0.512 Passed (L/299) -- 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 10' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available ' Required Dead Snow Total 1 - Stud wall - HF 3.50" 3.50" 2.37" 1147 1852 2999 Blocking 2 - Stud wall - HF 3.S0" 3.50" 2.37" 1147 1852 2999 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing intervals comments Top Edge (Lu) 10' 7" o/c Bottom Edge (Lu) 10' 7" o/c -Maximum allowable bracing intervals based on applied load. VerticallLoads Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 10' 7" N/A 6.8 1 - Uniform (PSF) 0 to 10' 7" (Front) 14' 15.0 25.0 Default Load System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jeffrey Kranz Bykonen Carter Quinn (206) 264-7784 jk@bcq-se.com 5/17/2021 3:41:31 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Cooper Covered Deck Page 1 / 1 WINUUVV) PROPOSED WINDOW CONFIGURATION:- 51-11111 2 161-011 0 100 3'- 6 54 " W x 54"H 1 v SL sill@26 " I 120"W x 80"H SGD UP -7 2T @12 11 3R 06.3 1IL11 F.L44LAU DECK JOISTS 0161, O.C. 4 PROPOSED DECK FRAMING SCALE: P) 1 )— 0 4 MEMBER REPORT PASSED vel, Beam 1 1 piece(s) 2 x 8 HF No.2 @ 16" OC &ier-all Length: 8` ?" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) ' Member Reaction (Ibs) 419 @ 2 1/2" 1367 (2.25") Passed (31%) -- 1.0 D + 1.0 L (All Spans) Shear (Ibs) 340 @ 10 3/4" 1088 Passed (31%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 834 @ 4' 3 1/2" 1284 Passed (65%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.129 @ 4' 3 1/2" 0.204 Passed (L/758) -- 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.162 @ 4' 3 1/2" 0.408 Passed (L/606) -- 1.0 D + 1.0 L (All Spans) TI-ProT"' Rating N/A N/A N/A -- N/A • Deflection criteria: ILL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available , Required Dead Floor Live Total 1 - Stud wall - HF 3.50" 2.25" 1.50" 86 343 429 1 1/4" Rim Board 2 - Stud wall - HF 3.50" 2.25" 1.50" 86 343 429 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. LateralBracing Bracing Intervals ` Comments Top Edge (Lu) 8' 5" o/c Bottom Edge (Lu) 8' 5" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.91) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 8' 7" 16" 15.0 60.0 Default Load System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Motes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-Iibrary. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Jeffrey Kranz Bykonen Carter Quinn (206) 264-7784 jk@bcq-se.com 5/17/2021 3:54:26 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Cooper Covered Deck Pagel/1 MEMBER. REPORT PASSED vel, Beam 2 & 3 1 piece(s) 4 x 12 HF No.2 D,,erall'Length:8' 7" u 0 Q All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Designs Results Actual @ Location Allowed Result LDF I Load: Combination (Pattern) Member Reaction (Ibs) 2618 @ 2" 4961 (3.50") Passed (53%) -- 1.0 D + 1.0 L (All Spans) Shear (Ibs) 1868 @ 1' 2 3/4" 3938 Passed (47%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 5190 @ 4' 3 1/2" 5752 Passed (90%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.093 @ 4' 3 1/2" 0.275 Passed (L/999+) -- 1.0 D + 1.0 L (All Spans) Total Load Dell. (in) 0.118 @ 4' 3 1/2" 0.412 Passed (L/841) -- 1.0 D + 1.0 L (All Spans) • Uenecuun crnena: LL (L/JUU) ana I L (LIZ'+u). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Stud wall - HF 3.50" 3.50" 1.85" 558 2060 2618 Blocking 2 - Stud wall - HF 3.50" 3.50" 1.85" 558 2060 2618 Blocking .y . ­111 -I ­­­ w '­y uv w .. aVNucu uucuiy aUUVC Ulan anU uic W11 WOU o dppllM LU Ule nlenlUer Uelny ❑eslyneu. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 7" o/c Bottom Edge (Lu) 8' 7" o/c •ridxununi dnuwdUie Uldany mieWdls oasea on appneo ioaa. Vertical Loads Location (Side) Tributary Width Head (0.90) Floor Live (1.00) comments 0 - Self Weight (PLF) 0 to 8' 7" N/A 10.0 -- 1 - Uniform (PSF) 0 to 8' 7" (Front) 8' 15.0 60.0 Default Load System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-Iibrary. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator 5/17/2021 4:04:14 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Cooper Covered Deck Pagel/1 Job Notes Jeffrey Kranz Bykonen Carter Quinn (206) 264-7784 jk@bcq-se.com ATCHazards by Location Search Information Address: 918 Spruce St, Edmonds, WA 98020, USA Coordinates: 47.80567869999999,-122.3661769 Elevation: 317 ft Timestamp: 2021-05-18T20:16:21.022Z Hazard Type: Seismic Reference ASCE7-16 Document: Risk Category: II Site Class: D-default Basic Parameters Name Value Description SS 1.284 MCER ground motion (period=0.2s) S1 0.452 MCER ground motion (period=l.Os) SMS 1.54 Site -modified spectral acceleration value SM1 * null Site -modified spectral acceleration value SDS 1.027 Numeric seismic design value at 0.2s SA SD1 * null Numeric seismic design value at 1.0s SA * See Section 11.4.8 wAdd itional Information Name Value Description SDC * null Seismic design category Fa 1.2 Site amplification factor at 0.2s F„ * null Site amplification factor at 1.0s CRS 0.91 Coefficient of risk (0.2s) CR1 0.896 Coefficient of risk (1.0s) PGA 0.546 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.655 Site modified peak ground acceleration 9t 0, 6P, i4v BYKONEN No- 2033 Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.BCQ-SE.com CARTER QUINN PROJECT: DATE: A STRUCTURAL I ENGINEERING DESIGNER: SHEET #: RMNEN Bykonen Carter Quinn CAWR 2033 6th Avenue, Ste 995 01AN11 Seattle, WA 98121 STIAM If lum Project Title. - Engineer: Project ID: Project Descr: Printed: 18 MAY 2021, 1:20P 'ole FootingEmbedded in Soil _ File.2021 Misc.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12,20.8.24 Code References Calculations per IBC 2012 1807.3, CBC 2013, ASCE 7-10 Load Combinations Used: ASCE 7-16 General Information Pole Footing Shape Circular Pole Footing Diameter .... , . ..... 18.0 in Calculate Min. Depth for Allowable Pressures Lateral Restraint at Ground Surface Allow Passive .................. 250.0 pcf Max Passive ..... . ............. 1,500.0 psf Point Load Controlling Values Governing Load Combination: +D+0,70E Lateral Load 0,6468 k Moment 5.013 k-ft Restraint @ Ground Surface Pressure at Depth Soil Surface Surface Lateral Restraint Actual 945.86 p sf� «�,3 N Allowable 968.75 psf 1: a Surface Retraint Force 3395.70 Ibs t m KIthimum. Required Depth, ' Footing Base Area 1.767 ft^2 Maximum Soil Pressure 1.449 ksf Applied Loads Lateral Concentrated Load (k) Lateral Distributed Loads (klf) Applied Moment (kft) Vertical Load (k) D : Dead Load k k/ft k-ft 0.960 k Lr : Roof Live k k/ft k-ft k L : Live k k/ft k-ft k S : Snow k k/ft k-ft 1.60 k W : Wind k k/ft k-ft k E : Earthquake 0.9240 k k/ft k-ft k H : Lateral Earth k k/ft k-ft k Load distance above TOP of Load above ground surface ground surface 7.750 ft ft BOTTOM of Load above ground surface ft Load Combination Results Forces @ Ground 8tirface Required Pressure at Depth Increas t oad Giinbinafiion Loads tak) Mornan#s = eft=k) 1 iept -ft actual=sliowr (psi aty'Of D Only 0,000 0.000 0.13 0.0 31.3 1,000 +D+S 0.000 0,000 0.13 0.0 31.3 1,000 +D+0,750S 0.000 0.000 0.13 0.0 31.3 1.000 +0.60D 0.000 0,000 0.13 0.0 31.3 1,000 +D+0.70E 0,647 5,013 3.88 945,9 968.8 1.000 +D+0.750S+0.5250E 0.485 3.760 3.50 869.6 875.0 1.000 +0.60D+0.70E 0,647 5.013 3.88 945.9 9683 1.000