REVIEWED BLD-RESUB 1-Shearwall panel specsRESUB Aug 23 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY CITY OF EDMONDS ..... BUILDING DEPARTMENT ............................... ' �IiMrIN•AhL { Design Flexibility 4 ' oOk MF ` a Strong -Tie 0 Delivering Customization to Factory -Built Shearwalls Prefabricated shearwalls from Simpson Strong -Tie are synonymous with high quality and performance. Over the years, we have worked diligently to ensure that our Strong -Wall® line of code -listed shearwalls provide enhanced structural support, allow design flexibility and help lower labor costs through easier installation. Simpson Strong -Tie introduces the latest enhancements to our customizable and field-trimmable Strong -Wall® Wood Shearwall (WSW) product line. The holdowns installed on the WSW now provide both front and side access, facilitating installation of the anchorage attachment in various framing conditions. The front access opening also allows for easy inspection of the connection to the anchor bolt. The connection from the top of the panel to the framing has also been updated. There are now two options, designed to accommodate different installer preferences. Simpson Strong -Tie maintains a large group of dedicated engineers and field representatives to support your efforts — because your best chance of creating a long-lasting structure is before you start building it. aw _ t Introduction For 60 years, Simpson Strong Tie has focused on creating structural products that help people build safer and stronger homes and buildings. A leader in structural systems research and technology, Simpson Strong Tie is one of the largest suppliers of structural building products in the world. The Simpson Strong Tie commitment to product development, engine- -- testing and training is evident in the consistent quality and delivery of its products and services. For more information, visit the company's website at www.strongtie.com. The Simpson Strong -Tie Company Inc. "No Equal" pledge includes: • Quality products value -engineered for the lowest installed cost at the highest -rated performance levels • The most thoroughly tested and evaluated products in the industry • Strategically located manufacturing and warehouse facilities • National code agency listings • The largest number of patented connectors in the industry ° • Global locations with an international sales team d • In-house R&D and tool and die professionals • In-house product testing and quality control engineers `gib • Support of industry groups including AISI, AITC, ASTM, ASCE, AWC, AWPA, ACI, AISC, CSI, CFSEI, ICFA, NBMDA, NLBMDA, SDI, SETMA, SFA, SFIA, STAFDA, SREA, NFBA, TPI, WDSC, WIJMA, WTCA and local engineering groups. The Simpson Strong Tie Quality Policy We help people build safer structures economically. We do this by designing, engineering and manufacturing "No Equal" structural connectors and other related products that meet or exceed our customers' needs and expectations. Everyone is responsible for product quality and is committed to ensuring the effectiveness of the Quality Management System. Karen Colonias Chief Executive Officer Getting Fast Strong -Tie WA 0 --d. 0 Northwest Q NortM1east - S.0 h..et - S—h— Technical Support When you call for engineering technical support, we can help you quickly if you have the following information at hand. This will help us to serve you promptly and efficiently. • Which Simpson Strong Tie® catalog are you using? (See the front cover for the catalog number) • Which Simpson Strong Tie product are you using? • What is your design code and building jurisdiction? • Is your structure residential or commercial? • What is your application? • What is your load requirement? nq . •00 Registered We Are ISO 9001-2008 Registered Simpson Strong Tie is an ISO 9001-2008 registered company. ISO 9001-2008 is an internationally - recognized quality assurance system which lets our domestic and international customers know that they can count on the consistent quality of Simpson Strong Tie° products and services. 800-999-5099 � www.strongtie.com All rights reserved. This catalog may not be reproduced in whole or in part without the prior written approval of Simpson Strong Tie Company Inc. General Notes and Table of Contents General Notes These General Notes are provided to ensure proper design, use and installation of the Simpson Strong Tie® Strong -Wall® Wood Shearwall and must be followed fully. a. Install products according to this catalog. Changes in installation methods or modifications to the product and associated systems (other than those indicated in this document) should only be made by a design professional of record. Altered installation procedures and the performance of modified products are the sole responsibility of the design professional of record. b. The building shall be designed in accordance with the appropriate building code and meet local, state, and federal requirements. Verify design requirements with the local building official. Concrete foundation design remains the responsibility of the design professional of record. Table of Contents General Notes ....................................................... 5 Strong -Wall° Wood Shearwall Features and Benefits ............................................ 6 Strong -Wall° Wood Shearwall Applications............ 7 Product and Kit Descriptions ............................. 8-9 Standard and Balloon Framing on Concrete Foundations .............................. 10-14 Garage Portal Systems on Concrete Foundations .............................. 15-17 Two -Story Stacked on Concrete Foundations .............................. 18-21 Anchorage Solutions ..................................... 22-28 Anchor Bolt Templates ......................................... 29 Installation Details .......................................... 30-47 Strong -Tie rM c. Strong -Wall® Wood Shearwalls are part of the overall lateral -force -resisting system of the structure. The design of this system, including a complete load path to transfer lateral forces from the structure to the ground, is the responsibility of the design professional of record. d. In addition to the information and instructions found in this catalog, all warnings, general notes and instructions, warranty information and terms and conditions of sale contained within the Strong -Wall® Shearwalls catalog apply. 5 Strong -Wall® Wood Shearwall Features and Benefits StrongTie 0 Delivering Easy -To -Install, Code -Listed Solutions The Simpson Strong Tie® Strong -Wall® Wood Shearwall is a specially designed, prefabricated, engineered -wood panel that helps structures resist lateral forces such as those created by earthquakes and high winds. The Strong -Wall® Wood Shearwall has been evaluated to the 2015 International Building Code® (IBC) and can help you resist these forces efficiently and confidently with the following features: • Code Listed — ICC-ES ESR-2652 and City of L.A. RR 25730 evaluated to the 2015 IRC/IBC • Field Adjustable — Can be field -trimmed and drilled • Stronger Wall — Narrow panel widths have significantly higher allowable loads than the original Wood Strong -Wall • More Applications — Suitable for residential, multi -family, and light -frame commercial construction and in balloon - framing applications up to 20 ft. • Front Access — Newly designed front access allows for easier anchor bolt installation and inspection • Easy to Install — Reusable templates locate the required holdown anchor bolts accurately in the foundation • Support and Service — Simpson Strong Tie provides unmatched engineering technical support and experienced field representation J 6 Strong -Wall® Wood Shearwall Applications Standard and Balloon -Framing Applications • Narrow wall spaces • Wall heights up to 20' HpplluaLlul I Portal Applications • Narrow wall spaces • Garages • Large windows and doors • Increased capacities when used in a portal Strong -Tie ro Balloon - Framing Application Product Storage Protect product from sun and water Two -Story Stacked Application • Narrow wall spaces • Multi -story installation kit (MSt) required (order separately) • Total assembled heights up to 24' C CAUTION: Wrap is slippery when wet or icy Use support blocks at 10' on -center to keep bundles out of mud and water 7 Product and Kit Descriptions Standard Product Description All Strong -Wall® Wood Shearwalls are supplied with top -of -wall shear transfer plates, nuts, washers, and installation instructions. Additionally, shearwalls 100 inches or less in height are supplied with four portal straps. Front View Strong -Tie 0 Back View Product and Kit Descriptions Alternative Top Connection Kit Required for alternative top connections using a single WSW -TOW plate installed from only one side with Strong -Drive® Connector screws. Strong -Wall" Wood Shearwall Alternative Connection Kit Model No. Contents WSW-TOWI2KT (20) 010 x 1 Y2" SD Connector Screws (2) /a x 6" SDS Heavy -Duty Connector Screws WSW-T0W18KT (28) #10 x 1 Y2" SD Connector Screws (4) /a x 6" SDS Heavy -Duty Connector Screws WSW-T0W24KT (40) #10 x 1 Y2" SD Connector Screws (8) /a x 6" SDS Heavy -Duty Connector Screws 1. Use kit fasteners to attach (1) of the (2) WSW-TOWXXKT plates included with the Strong -Wall Wood shearwall. Plate may be installed on either panel face. Portal Kits (Included with all panels 100" or less in height) Required for portal -frame applications. Kit includes four portal straps and comes standard with all panels that are 100" or less in height. Order the kit separately if using panels that are more than 100" tall in a portal application. I06MIkiMNT, Riviyaa 1 �o S6 Identification on all SIDS screw heads 6" Thread Length Strong -Drive® SDS HEAVY-DUTY CONNECTOR Screw U.S. Patent 6,109,850; 5,897,280; 7,101,133 Strong -Tie Identification on all SD screw heads The 4CUT point reduces installation torque and makes driving easier. Strong -Drive® SD10 CONNECTOR Screw U.S. Patent 7,101,133 Multi -Story Kits (MSK) Required for two-story stacked applications. Kit includes two holdowns with pre -attached bolts and a bearing block. See page 18 for two-story stacked details. Model No.: WSW-MSKI2KT, WSW-MSKI8KT, WSW-MSK24KT Standard and Balloon Framing on Concrete Foundations Strong -Wall® Wood Shearwall Product Data Model No. W (in.) H (in.) Anchor Bolts Total Wall Weight (lb.) Quantity Diameter (in) WSW12x7 12 78 2 7/8 100 WSW18x7 18 78 2 7/8 145 WSW12x7.5 12 851/2 2 7/8 110 WSW18x7.5 18 851/2 2 7/8 155 WSW12x8 12 931/4 2 7/8 115 WSW18x8 18 931/4 2 7/8 165 WSW248 24 931/4 2 1 225 WSW12x9 12 1051/4 2 7/a 130 WSW18x9 18 1051/4 2 7/8 185 WSW249 24 1051/4 2 1 245 WSW12x10 12 1171/4 2 7/8 140 WSW18x10 18 1171/4 2 7/8 205 WSW2410 24 1171/4 2 1 270 WSW12x11 12 1291/4 2 7/8 150 WSW18x11 18 1291/4 2 7/8 220 WSW24x11 24 1291/4 2 1 295 WSW12x12 12 1411/4 2 7/8 165 WSW18x12 18 1411/4 2 7/8 240 WSW24x12 24 1411/4 2 1 320 WSW18x13 18 1531/4 2 7/8 255 WSW24x13 24 1531/4 2 1 345 WSW2414 24 168 2 1 375 WSW24x16 24 192 2 1 425 WSW18x20 18 240 2 7/8 385 WSW2420 24 240 2 1 520 1. For heights not listed, order the next tallest panel and trim to fit. Minimum trimmed height for all panels is 741/2". 2. All panels come with two pre -attached holdowns, two standard hex nuts, two flat washers, two WSW -TOW top -connection plates (width based on panel model), and installation instructions. 3. All panels are 31/2" thick. Stror Wood S First -Story Installation with Wood Floor System Specify panel height from top of foundation to underside of the top plates or beam. 1/4" x 6" SIDS screws (order separately) � /\ Verify panel is plumb. Use metal shims (Model No. WSW-CS1) at the base if required. Place Strong-Wall®Wood Shearwall over the anchor bolts and secure with hex nuts and structural washers (provided). Snug tight fit required. • 15/16 wrench required for 7/8' nut. - • 11/2" wrench required for 1" nut. Foundation desi (size and reinforcemej by Design Rake Wall Application Vu Strong -Tie Simpson Strong -Tie® LTP4 or A35 framing angles Strong -Wall® Wood Shearwall 1 Shim N 10 Standard Installation Standard and Balloon Framing on Concrete Foundations Simpson Strong Tie® Strong -Wall® Wood Shearwalls combine design flexibility with performance. Field trimmable, they can be customized to accommodate varying heights or rake walls. They are evaluated to the 2015 IRC/IBC and are listed by ICC-ES in ESR-2652 and the City of LA in RR 25730. Installation • All panels may be field trimmed to a minimum of 741/2". Trim height from top of panel only, do not trim from sides or bottom. Drilling holes in the Strong -Wall® Wood Shearwalls is not allowed except as shown on page 42. Strong -Tie 0 Strong -Wall® Wood Shearwall Naming Legend WSW18x8-93 Wood _:�[— I— Actual Shearwall Width Height (in.) (in.) Nominal Height (ft.) • Anchor -bolt nuts should be snug tight. w(provided with th WWSW SW) installed • Maximum shim thickness between the shearwall from front and back. and top plates or header is 7/a". • Walls may also be used in 2x6 wall framing. Install the panel flush to the outside face of the framing and add furring to the opposite side. • Standard top -of -wall connections install with nails. Codes: ICC-ES ESR-2652, City of L.A. RR 25730 (0 Attaches to header or top plates. Align WSW -TOW onotches with bottom of top plates. 0 1 WSW -TOW standard or alternative top connection. \II��/III Precut chase for wiring and openings for plumbing and electrical. Form -mounted templates enable precise anchor bolt placement before the pour. Standard Top Maximum Connection /a' shim as Also applicable for necessary portal applications for tight fit. with a header. WSW -TOW installs with 10tl x 2'/z" min. length nails. WSW -TOW (provided with WSW) installed on one side only. Field trimmable and drillable. r \� I Align WSW -TOW notches with bottom WSW -AB of top plates. Hex nut and Ya" x 6" SIDS structural washer. Hea Conn screw o: 0 0o O o0 °o°• o° Foundation design (size and reinforcement) by Designer. Standard Installation Alternative Top \I Connection Also applicable Max 7/8"shim for portal as necessary for tight fit. applications with a header. Approx. _ WSW -TOW installs with a combination of 1/a" x 6"SDS Heavy -Duty Connector screws and #10 x 1 �/z" SD Connector screws (order separately as WSW-TOWXXKT). #10x1�/z" SD Connector screw Optional 1 "-diameter by Ya"-deep counterbore. FE Alternative Top Connection Side View Standard and Balloon Framing on Concrete Foundations Strong -Wall° Wood Shearwall Standard Application on Concrete Foundation Strong -Tie 2,500 psi Concrete 3,000 psi Concrete Strong -Wall Allowable Seismic' Wind Seismic' Wind Wood Shearwall Models Vertical Load, P (lb.)° Allowable ASD Shear Load, V (lb.) Drift at Allowable Shear, (in.) Anchor Tension at Allowable Shear, T Allowable ASD Shear Load V (lb.) Drift at Allowable Shear, (in.),o Anchor Tension at Allowable S Obi, T Allowable ASD Shear Load V (lb.) Drift at Allowable Shear, (in.) Anchor Tension at Allowable Shear, T Allowable ASD Shear Load V (lb.) Drift at Allowable Shear, (in.),o Anchor Tension at Allowable S (lb )� T 1,000 1,065 0.31 10,285 1,380 0.43 13,375 1,065 0.31 10,285 1,380 0.43 13,375 WSW12x7 4,000 1,065 0.31 10,285 1,380 0.43 13,375 1,065 0.31 10,285 1,380 0.43 13,375 7,500 1,065 0.31 10,285 1,380 0.43 13,370 1,065 0.31 10,285 1,380 0.43 13,375 1,000 2,475 0.31 13,865 2,980 0.4 16,675 2,475 0.31 13,865 3,225 0.43 18,040 WSW18x7 4,000 2,475 0.31 13,865 2,710 0.36 15,160 2,475 0.31 13,865 3,225 0.43 18,040 7,500 2,475 0.31 13,865 2,395 0.32 13,395 2,475 0.31 13,865 2,910 0.39 16,280 1,000 5,515 0.29 22,710 5,515 0.32 22,710 5,515 0.29 22,710 5,515 0.32 22,710 WSW24x79 4,000 5,515 0.29 22,710 5,400 0.31 22,240 5,515 0.29 22,710 5,515 0.32 22,710 7,500 5,515 0.29 22,710 4,950 0.29 20,390 5,515 0.29 22,710 5,515 0.32 22,710 1,000 960 0.39 11,125 1,245 0.53 14,420 960 0.39 11,125 1,245 0.53 14,420 WSW12x8 4,000 960 0.39 11,125 1,245 0.53 14,420 960 0.39 11,125 1,245 0.53 14,420 7,500 960 0.39 11,125 1,155 0.49 13,370 960 0.39 11,125 1,245 0.53 14,420 1,000 2,430 0.39 16,245 2,490 0.42 16,675 2,430 0.39 16,245 2,925 0.50 19,560 WSW18x8 4,000 2,430 0.39 16,245 2,265 0.38 15,160 2,430 0.39 16,245 2,695 0.46 18,045 7,500 2,430 0.39 16,245 2,000 0.34 13,395 2,430 0.39 16,245 2,435 0.41 16,280 1,000 4,945 0.37 24,355 4,840 0.40 23,830 4,945 0.37 24,355 5,515 0.45 27,150 WSW24x8 4,000 4,945 0.37 24,355 4,515 0.37 22,240 4,945 0.37 24,355 5,360 0.44 26,395 7,500 4,945 0.37 24,355 4,140 0.34 20,390 4,945 0.37 24,355 4,985 0.41 24,540 1,000 790 0.43 10,310 1,020 0.60 13,335 790 0.43 10,310 1,020 0.60 13,335 WSW12x9 4,000 790 0.43 10,310 1,020 0.60 13,335 790 0.43 10,310 1,020 0.60 13,335 7,500 790 0.43 10,310 1,020 0.60 13,335 790 0.43 10,310 1,020 0.60 13,335 1,000 1,920 0.43 14,505 2,210 0.53 16,675 1,920 0.43 14,505 2,515 0.60 18,980 WSW18x9 4,000 1,920 0.43 14,505 2,010 0.48 15,160 1,920 0.43 14,505 2,390 0.57 18,045 7,500 1,920 0.43 14,505 1,775 0.42 13,395 1,920 0.43 14,505 2,155 0.51 16,280 1,000 4,190 0.43 23,275 4,290 0.46 23,830 4,190 0.43 23,275 5,035 0.54 27,985 WSW249 4,000 4,190 0.43 23,275 4,000 0.43 22,240 4,190 0.43 23,275 4,750 0.51 26,395 7,500 4,190 0.43 23,275 3,670 0.40 20,390 4,190 0.43 23,275 4,415 0.48 24,540 1,000 630 0.50 9,175 810 0.67 11,810 630 0.50 9,175 810 0.67 11,810 WSW12x10 4,000 630 0.50 9,175 810 0.67 11,810 630 0.50 9,175 810 0.67 11,810 7,500 630 0.50 9,175 810 0.67 11,810 630 0.50 9,175 810 0.67 11,810 1,000 1,715 0.49 14,440 1,980 0.59 16,675 1,715 0.49 14,440 2,225 0.67 18,715 WSW18x10 4,000 1,715 0.49 14,440 1,800 0.54 15,160 1,715 0.49 14,440 2,145 0.64 18,045 7,500 1,715 0.49 14,440 1,590 0.48 13,395 1,715 0.49 14,440 1,935 0.58 16,280 1,000 3,675 0.48 22,740 3,850 0.54 23,830 3,675 0.48 22,740 4,520 0.63 27,985 WSW24x10 4,000 3,675 0.48 22,740 3,590 0.50 22,240 3,675 0.48 22,740 4,265 0.60 26,395 7,500 3,675 0.48 22,740 3,295 0.46 20,390 3,675 0.48 22,740 3,965 0.55 24,540 1,000 575 0.55 9,190 735 0.73 11,810 575 0.55 9,190 735 0.73 11,810 WSW12x11 4,000 575 0.55 9,190 735 0.73 11,810 575 0.55 9,190 735 0.73 11,810 7,500 575 0.55 9,190 735 0.73 11,810 575 0.55 9,190 735 0.73 11,810 1,000 1,510 0.53 14,010 1,800 0.67 16,675 1,510 0.53 14,010 1,975 0.73 18,335 WSW18x11 4,000 1,510 0.53 14,010 1,635 0.61 15,160 1,510 0.53 14,010 1,945 0.72 18,045 7,500 1,510 0.53 14,010 1,445 0.54 13,395 1,510 0.53 14,010 1,755 0.65 16,280 1,000 3,295 0.53 22,485 3,490 0.58 23,830 3,295 0.53 22,485 4,100 0.69 27,985 WSW2411 4,000 3,295 0.53 22,485 3,260 0.55 22,240 3,295 0.53 22,485 3,865 0.65 26,395 7,500 3,295 0.53 22,485 2,985 0.50 20,390 3,295 0.53 22,485 3,595 0.60 24,540 See foonotes on page 13. 12 Standard and Balloon Framing on Concrete Foundations Strong -Wall° Wood Shearwall Standard Application on Concrete Foundation (cont.) 2,500 psi Concrete 3,000 psi Concrete Strong -Wall Allowable Seismic' Wind Seismic' Wind Wood Shearwall Models Vertical Load, P (Ib.)° Allowable ASD Shear Load, V (lb.) Drift at Allowable Shear, (in.) Anchor Tension at Allowable Shear, T (lb.)„ Allowable ASD Shear Load V (lb.) Drift at Allowable Shea (in.) Anchor Tension at Allowable Shear, T (lb.)„ Allowable ASD Shear Load V (lb.) Drift at Allowable Shear, (in.) Anchor Tension at Allowable Shear, T (lb.)„ Allowable ASD Shear Load V (lb.) Drift at Allowable Shear, 0 (in.) Anchor Tension at Allowable Shear, T (lb.)" 1,000 485 0.62 8,540 625 0.80 10,915 485 0.62 8,540 625 0.80 10,915 WSW12x12 4,000 485 0.62 8,540 625 0.80 10,915 485 0.62 8,540 625 0.80 10,915 7,500 485 0.62 8,540 625 0.80 10,915 485 0.62 8,540 625 0.80 10,915 1,000 1,340 0.58 13,580 1,645 0.75 16,675 1,340 0.58 13,580 1,755 0.80 17,770 WSW18x12 4,000 1,340 0.58 13,580 1,495 0.68 15,160 1,340 0.58 13,580 1,755 0.80 17.770 7,500 1,340 0.58 13,580 1,320 0.60 13,395 1,340 0.58 13,580 1,605 0.73 16,280 1,000 2,920 0.58 21,795 3,195 0.66 23,830 2,920 0.58 21,795 3,750 0.77 27,985 WSW2412 4,000 2.920 0.58 21,795 2,980 0.61 22,240 2,920 0.58 21,795 3,540 0.73 26,395 7,500 2,920 0.58 21,795 2.735 0.56 20,390 2,920 0.58 21,795 3,290 0.68 24,540 1,000 1,190 0.63 13,065 1,515 0.85 16,675 1,190 0.63 13,065 1,555 0.87 17,100 WSW18x13 4,000 1,190 0.63 13,065 1,380 0.77 15,160 1,190 0.63 13,065 1,555 0.87 17,100 7,500 1,190 0.63 13,065 1,220 0.68 13,395 1,190 0.63 13,065 1,480 0.83 16,280 1,000 2,590 0.64 20,970 2,945 0.74 23,830 2,590 0.64 20,970 3,445 0.87 27,865 WSW24x13 4,000 2,590 0.64 20,970 2,750 0.69 22,240 2.590 0.64 20,970 3,260 0.82 26,395 7,500 2,590 0.64 20,970 2,520 0.63 20,390 2,590 0.64 20,970 3,035 0.76 24,540 1,000 960 0.69 11,580 1.245 0.93 14,995 960 0.69 11,580 1,245 0.93 14,995 WSW18x149 4,000 960 0.69 11,580 1,245 0.93 14,995 960 0.69 11,580 1,245 0.93 14,995 1,000 2,175 0.69 19,300 2,685 0.89 23,830 2,175 0.69 19,300 2,815 0.93 24,970 WSW2414 4,000 2,175 0.69 19.300 2,505 0.83 22,240 2,175 0.69 19,300 2,815 0.93 24,970 1,000 830 0.79 11,420 1,085 1.07 14,945 830 0.79 11,420 1,085 1.07 14,945 WSW18x169 4,000 830 0.79 11,420 1,085 1.07 14,945 830 0.79 11,420 1,085 1.07 14,945 1,000 1,810 0.80 18,330 2,350 1.04 23,830 1,810 0.80 18,330 2,400 1.07 24,355 WSW24x16 4,000 1,810 0.80 18,330 2,195 0.97 22,240 1,810 0.80 18,330 2,400 1.07 24,355 1,000 650 0.90 10,105 855 1.20 13,225 650 0.90 10,105 855 1.20 13,225 WSW18x189 4,000 650 0.90 10,105 855 1.20 13,225 650 0.90 10,105 855 1.20 13,225 1,000 1,420 0.92 16,220 1,890 1.20 21,555 1,420 0.92 16,220 1,890 1.20 21,555 WSW24189 4,000 1,420 0.92 16,220 1,890 1.20 21,555 1,420 0.92 16.220 1,890 1.20 21,555 1,000 545 1.03 9,385 700 1.33 12,020 545 1.03 9,385 700 1.33 12,020 WSW18x20 4,000 545 1.03 9,385 700 1.33 12,020 545 1.03 9,385 700 1.33 12,020 1,000 1,180 1.02 14,940 1,510 1.33 19,140 1,180 1.02 14,940 1,510 1.33 19.140 WSW2420 4,000 1,180 1.02 14,940 1,510 1.33 19,140 1,180 1.02 14,940 1,510 1.33 19,140 1. Allowable shear loads are applicable to installations on concrete with specified compressive strengths as listed using the ASD basic (IBC Section 1605.3.1) or the alternative basic (IBC Section 1605.3.2) load combinations. 2. Load values include evaluation of bearing stresses on concrete foundations and do not require further evaluation by the Designer. For installations on masonry foundations, bearing capacity shall be evaluated by the Designer. 3. Seismic design based on 2015 IBC using R = 6.5. For other codes, use the seismic coefficients corresponding to light -frame bearing walls with wood structural panels or sheet -steel panels. 4. Allowable vertical load denotes the total maximum concentric vertical load permitted on the panel acting in combination with the allowable shear loads. 5. Allowable shear, drift and anchor tension values may be interpolated for intermediate height or vertical loads. For panels 741/2"-78" tall, use the values for a 78"-tall panel. 6. High -strength anchor bolts are required for anchor tension forces exceeding the allowable load for standard -strength bolts tabulated on pages 23-24. See pages 22-29 for WSW -AB anchor bolt information and anchorage solutions. All panels taller than 18' require a 2x6 minimum full -height stud attached to each side. Attach using 10d common nails at 16" o.c. See page 14 for allowable out -of -plane and axial capacities. WSW24x7 must be trimmed from a WSW24x8 shearwall. WSW18x14, 16, and 18, and WSW24x18 shearwalls are trimmed from a 20 ft.-tall panel. 10. Drifts at lower design shear may be linearly reduced. Tabulated anchor tension values assume no resisting vertical load. Anchor tension loads at design shear values and including the effect of vertical load may be determined using the following equation: T=[(VxH)/B]-P/2,where: T = Anchor tension load (lb.) V = Design shear load (lb.) P = Applied vertical load (lb.) H = Panel height (in.) B = Moment arm (in.); 8.06" for WSW12, 13.94" for WSW1 8,18.94" for WSW24. 13 Standard and Balloon Framing on Concrete Foundations Strong -Wall® Wood Shearwall Allowable Out -of -Plane Loads for Single -Story Walls on Concrete Foundations (PSF) Strong -Tie Panel Attachment Strong -Wall Wood Shearwall Model Nominal Height of Shearwall (ft.) 7 71h 8 9 10 11 12 13 14 16 18 20 WSW12 255 235 215 190 155 115 60 N/A N/A N/A N/A N/A Top Plates WSW18 230 210 195 170 155 115 90 70 55 35 25 20 WSW24 250 225 210 185 155 115 90 70 55 35 25 20 WSW12 280 255 205 150 110 85 60 N/A N/A N/A N/A N/A Header WSW18 185 170 155 140 110 85 70 N/A N/A N/A N/A N/A WSW24 140 130 120 105 95 85 170 N/A N/A N/A N/A N/A 1. Loads shown are at ASD level in pounds per square foot (PSF) of wall with no further increase allowed. 2. Loads consider a maximum deflection limit of H/240. 3. Allowable out -of -plane loads can be applied in combination with the panel allowable vertical loads shown on pages 12-13. 4. Allowable values for header panel attachment assume a maximum header depth of 14". Use a load reduction factor of 0.88 and 0.78 for 16"- and 18"-deep headers respectively. 5. Allowable values shown for header panel attachment require the use of the portal kit to resist header rotation. 6. N/A = Not Applicable. Strong -Wall® Wood Shearwall Axial Capacities for Single -Story Walls on Concrete Foundations (lb.) Strong -Wall Nominal Height of Shearwall (ft.) Wood Shearwall Model 7 7.5 8 9 10 11 12 13 14 16 18 20 WSW12 32,400 27,700 23,700 19,000 15,400 12,800 10,800 N/A N/A N/A N/A N/A WSW18 40,900 40,900 40,900 33,100 26,900 22,300 18,800 16,000 13,300 10,200 8,100 6,600 WSW24 1 58,000 1 56,200 48,100 38,400 1 31,300 1 25,900 21,800 1 18,600 15,500 11,900 9,400 7,600 1. Allowable ASD vertical load is the lesser of the WSW panel buckling capacity and concrete bearing capacity beneath the holdowns assuming a minimum specified concrete compressive strength f'C = 2,500 psi. 2. Allowable vertical loads assume concentric point load or uniformly distributed load without lateral loads present. For combined lateral and vertical loads, see pages 12-13. 3. Tabulated loads apply to single -story panels on concrete foundations. 4. N/A = Not Applicable. 14 Garage Portal Systems on Concrete Foundations The Strong -Wall® Wood Shearwall garage portal system provides higher shear capacity with reduced concrete anchorage requirements. Portal walls may be used in single- or double -portal applications and shall be installed with a minimum 31/e" x 9'/4" single- or multiple -ply header depending upon loading and span requirements. Codes: ICC-ES ESR-2652, City of L.A. RR25730 For product data and naming scheme information, see pages 10-11. Garage Header Rough Opening Height Model H Curb Rough Opening No. (in.) Height (in.) WSW12x7 5Y2 6'-11 Y2' WSW18x7 6 7'-0' WSW24x7 WSW12x7.5 WSW18x7.5 0 7'-1Y2 WSW24x7.5 WSW12x8 5Y2 8'-23/42 WSW18x8 6 8'-3'/42 WSW24x8 1. If required rough opening height exceeds table value, specify next taller panel and trim as necessary. The Strong -Wall Wood Shearwalls may be trimmed to a minimum height of 74Y2". 2. Furring down garage header may be required for correct rough opening height. 3. WSW24x7 and WSW24x7.5 must be trimmed from a WSW24x8 shearwall. Installation • Portal -frame connection kit is required for portal -frame applications. • All panels may be trimmed to a minimum of 741/2". Trim height from top of panel only, do not trim from sides or bottom. Drilling holes in the Strong -Wall Wood Shearwalls is not allowed except as shown on page 42. • Anchor -bolt nuts should be snug tight. • Maximum shim thickness between Strong -Wall Wood Shearwalls and the top plates or header is 7/8". • Standard top -of -wall connections install with nails. • Walls may also be used in 2x6 wall framing. Install the panel flush to the outside face of the framing and add furring to the opposite side. • Walls may be installed with solid or multi -ply headers, see page 47 Detail 4, 5/WSW4 for fastening and furring requirements. Portal Frame Connection Kit Model No. Contents WSW-PK 4 (10 Gauge) WSW -PS Straps 1. Portal -frame connection kit comes with panels that are 100" or less in height. The kit must be ordered separately for panels over 100" tall. Simpson Strong -Tie® LSTA12 strap installed on each side of the beam to the post (1,000 lb. uplift capacity min.). Foundation design (size and reinforcement) by Designer. Single Portal Installation Strong -Tie M WSW -TOW portal connection. Align notches with bottom of header. See page 11 for header connection. Verify panel is plumb. Use metal shims (Model No. WSW-CS1) at the base if required. See page 10 for connection to foundation. 15 Garage Portal Systems on Concrete Foundations Portal Design Information A portal frame under lateral loads causes the portal header to experience internal stresses in addition to those created by the primary loads (live, dead and snow). These additional stresses are called induced forces and must be considered when designing portal headers. To account for the induced forces from lateral loads, a concentrated end moment equal to the top -of -panel moment must be placed at the end of the beam that is connected to the WSW panel. For WSW12 and WSW18 panels, the moment induced into the portal header must be taken as 20% and 10%, respectively, of the total lateral moment. The total lateral moment is calculated as the design shear times the panel height. For headers with typical residential uniform loads, the induced moment and shear forces from a portal -frame system do not control the design. This is due to the 1.60 load duration factor (CD) used in design and the induced stresses from wind and seismic loads. The lateral and vertical loads shown on page 17 for portal frames assume that the header size falls within the portal -frame parameters listed in the table. Strong -Wall" Wood Shearwall Portal Header Design Parameters Header Design Parameter Allowable Range Width 31/e" — 5Yx" Depth 9Ya" —18" Clear Span 8' —18' 6" K 90 Ib.dn. — 4,000 lb./in. 1. Single- or multiple -ply header members may be used. 2. Secondary moment, shear and axial forces shall be considered in header design. 3. Header design shall be by Designer and assume gravity loads only induce simple span moments in beam. 4. Header stiffness (K) for use in WSW portal system may be determined using the following equation: K = (E x b x d3) / 1213 where: E = Header modulus of elasticity (psi) b = Header width (in.) d = Header depth (in.) L = Header clear span (in.) See page 11 for top plate Shear transfer connection. by Designer. I\ I\ I u I I Header by Designer — I 3�/a" min. width x 9'/d' min. depth. Header support i post by Designer. 8' min., 18'-6" max. Column base detail by Designer (not shown). �L (1,000 lb. uplift capacity min.) 0 a o ° ° o Foundation design 0' (size and reinforcement) o by Designer. Alternate Garage Front Option 1 Strong -Tie See pages 11 and 15 for header connection. Rough opening height. Curb ° o Alternate Garage Front Option 2 Alternative Garage Front Options These alternative garage -front options may be used for applications when the Strong -Wall® Wood Shearwall is installed at the full height (option 1) or without the additional Portal -Frame Kit (option 2), when higher capacity or reduced concrete anchorage is not needed. Refer to the Standard Application on Concrete Foundations on pages 12-13 for product data and allowable load values. For Garage Wall Option 2, the Designer shall design for: 1. Shear transfer 2. Out -of -plane loading effect 3. Increased overturning and drift due to additional height 16 Garage Portal Systems on Concrete Foundations Strong -Tie 0 Strong -Wall° Wood Shearwall Single -Wall Garage Portal System on Concrete Foundation 2,500 psi Concrete 3,000 psi Concrete Allowable Seismic' Wind Seismic' Wind Strong -Wall Wood Shearwall Model Vertical Load, P (lb.)5 Allowable ASD Shear Load,V (lb.) Drift at Allowable Shear,A (in.)' Anchor Tension at Allowable Shear ,T (lb.)'. Allowable ASD Shear Load V Drift at Allowable Shear,A (in.)' Anchor Tension at Allowable Shear,T (Ib.),a (lb Allowable ASD Shear Load, V (Ib.) Drift at Allowable Shear,A (in.) Anchor Tension at Allowable Shear,T (lb.)'o Allowable ASD Shear Load V (lb.) Drift at Allowable Shear,9A On. Anchor Tension at Allowable Shear,T (lb.)10 1,000 1,645 0.38 12,750 2,135 0.53 16,525 1,645 0.38 12,750 2,135 0.53 16,525 WSW12x7 4,000 1,645 0.38 12,750 1,955 0.49 15,150 1,645 0.38 12,750 2,135 0.53 16,525 7,500 1,645 0.38 12,750 1,730 0.43 13,370 1,645 0.38 12,750 2,100 0.52 16,255 1,000 3,225 0.38 16,235 3,310 0.42 16,675 3,225 0.38 16,235 3,350 0.43 16,880 WSW18x7 4,000 3,225 0.38 16,235 3,010 0.38 15,160 3,225 0.38 16,235 3,350 0.43 16,880 7,500 3,225 0.38 16,235 2,660 0.34 13,395 3,225 0.38 16,235 3,230 0.41 16,280 1,000 1,520 0.41 12,900 1,965 0.57 16,670 1,520 0.41 12,900 1,970 0.57 16,720 WSW12x7.5 4,000 1,520 0.41 12,900 1,785 0.51 15,150 1,520 0.41 12,900 1,970 0.57 16,720 7,500 1,520 0.41 12,900 1,575 0.45 13,370 1,520 0.41 12,900 1,915 0.55 16,255 1,000 2,955 0.41 16,300 3,020 0.45 16,675 2,955 0.41 16,300 3,350 0.50 18,500 WSW18x7.5 4,000 2,955 0.41 16,300 2,745 0.41 15,160 2,955 0.41 16,300 3,270 0.48 18,045 7,500 2,945 0.41 16,260 2,425 0.36 13,395 2,955 0.41 16,300 2,950 0.44 16,280 1,000 1,310 0.44 12,110 1,695 0.60 15,690 1,310 0.44 12,110 1,695 0.60 15,690 WSW12x8 4,000 1,310 0.44 12,110 1,635 0.58 15,150 1,310 0.44 12,110 1,695 0.60 15,690 7,500 1,310 0.44 12,110 1,445 0.51 13,370 1,310 0.44 12,110 1,695 0.60 15,690 1,000 2,610 0.44 15,730 2,770 0.49 16,675 2,610 0.44 15,730 3,250 0.58 19,560 WSW18x8 4,000 2,610 0.44 15,730 2,520 0.45 15,160 2,610 0.44 15,730 2,995 0.53 18,045 7,500 2,610 0.44 15,730 2,225 0.40 13,395 2,610 0.44 15,730 2,705 0.48 16,280 1. Allowable shear loads are applicable to installations on concrete with specified compressive strengths as listed using the ASD basic (IBC Section 1605.3.1) or the alternative basic (IBC Section 1605.3.2) load combinations. 2. Load values include evaluation of bearing stresses on concrete foundations and do not require further evaluation by the Designer. For installations on masonry foundations, bearing capacity shall be evaluated by the Designer. 3. Seismic design based on 2015 IBC using R = 6.5. For other codes, use the seismic coefficients corresponding to light -frame bearing walls with wood structural panels or sheet -steel panels. 4. Allowable values shown apply to Single -Wall Garage Portal Systems. The allowable shear load for a Double -Wall Garage Portal System, which consists of two walls with a header continuous across both panels, may be taken as twice the table value. 5. Allowable vertical load denotes the total maximum concentric vertical load permitted on the panel acting in combination with the allowable shear loads. 6. Allowable shear, drift and anchor tension values may be interpolated for intermediate height or vertical loads. For panels 741h"-78" tall, use the values for a 78"-tall panel. 7. High -strength anchor bolts are required for anchor tension forces exceeding the allowable load for standard -strength bolts tabulated on pages 23-24. See pages 22-29 for WSW -AB anchor bolt information and anchorage solutions. 8. See page 14 for allowable out -of -plane and axial capacities. 9. Drifts at lower design shear may be linearly reduced. 10. Tabulated anchor tension values assume no resisting vertical load. Anchor tension loads at design shear values and including the effect of vertical load may be determined using the following equation: T=[(kxVxH)/B)-P/2,where: T = Anchor tension load (lb.) V = Design shear load (lb.) P = Applied vertical load (lb.) H = Panel height (in.) B = Moment arm (in.); 8.06" for WSW12, 13.94" for WSW18 k = Portal factor; 0.80 for WSW12 panels 931/4" or less in height, 0.90 for WSW18 panels 93Y4" or less in height, 1.00 for all other panels. 17 Two -Story Stacked on Concrete Foundations The same Strong -Wall® Wood Shearwall models used for standard applications on concrete may be used in stacked wall applications. See Product data tables below for models that may be used in this application. Codes: ICC-ES ESR-2652, City of L.A. RR 25730 For product naming scheme information, see page 11. Two -Story Stacked WSW Product Data - Upper Wall Model No. W (in.) H (in.) Total Wall Weight (lb.) WSW18x9 18 105Ya 185 WSW249 24 105Ya 245 WSW18x10 18 117Ya 205 WSW24x10 24 117Ya 270 WSW18x11 18 129Ya 220 WSW24x11 24 129Ya 295 WSW18x12 18 141 Ya 240 WSW24x12 24 141 /a 320 1. Order WSW-MSIOO(KT separately for two-story stacked applications. 2. See product data table on page 10 for footnotes. 3. The width of the upper wall should match the width of the lower wall. Two -Story Stacked WSW Product Data - Bottom Wall Model No. (in.) �) Anchor Bolts Total Wall Weight (lb.) Qty' Dia. (in.) WSW18x8 18 93Ya 2 7/8 165 WSW24x8 24 93'/a 2 1 225 WSW18x9 18 105'/a 2 7/8 185 WSW24x9 24 105'/a 2 1 245 WSW18x10 18 117Ya 2 7/8 205 WSW24x10 24 117Ya 2 1 270 WSW18x11 18 129'/a 2 7/8 220 WSW24x11 24 129'/a 2 1 295 WSW18x12 18 141Ya 2 7/8 240 WSW24x12 1 24 141Ya 1 2 1 320 1. See product data table on page 10 for footnotes. Multi -Story Connection Kit Model No. Contents WSW-MSKI2KT (2) Holdowns with pre -attached bolts (2) Standard hex nuts and flat washers (1) LSL bearing block Installation instructions WSW-MSKI8KT WSW-MSK24KT MSK connection kit47/ r(\ / Model WSW-MSKXXKT \ L1 (order separately). Foundation design (size and ' reinforcement) ` by Designer. StrongTie Second -story panel height includes wall height plus total floor depth. Two -Story Stacked Installation Strong -Wall® Wood Shearwall WSW -AB 18 U Z Z a 0 0 z O cc w z 0 a CO 0 N CO U Two -Story Stacked on Concrete Foundations Installation • All panels may be trimmed to a minimum of 741/2". Trim height from top of panel only, do not trim from sides or bottom. Drilling holes in the Strong -Wall° Wood Shearwalls is not allowed except as shown on page 42. • Anchor -bolt nuts should be snug tight. • Maximum shim thickness between the shearwall and the top plates or header is 7/e". • Walls may also be used in 2x6 wall framing. Install the panel flush to the outside face of the framing and add furring to the opposite side. • Standard top -of -wall connections install with nails. • The second -story panel must be the same width as the first -story panel. • When specifying the height of the second -story panels, add the total floor height, including sheathing, to the wall height, then subtract 2". See h3 definition on page 21. Hex nuts and structural washers provided with MSK kit. Nuts require a I / snug tight fit. IV MSK holdown installs with 10d x 2/2" min. length nails (fill all holes). Align LSL ! ° bearing block ° with first -story panel. See page I for Y top -plate connection ion. r� Two -Story Stacked MSK Connection Details Foundation design (size and reinforcement) by Designer. See page 11 for top -plate connection. See page 10 for connection to �.: foundation. Two -Story Stacked Installation Strong -Tie M 2x6 Framing Installation Alternative top connection recommended. See pages 39 and 44 for details. 2x6 Framing Installation Cut slots (1/4" wide max.) in the top plates to allow the MSK holdown to pass through. Do not notch the double top plates. o oo0o o I / o0 o I / \ oo o0 / 0o o0 First -Story Installation with Wood Floor System Specify panel height from top of foundation to underside of top plates. 19 Two -Story Stacked on Concrete Foundations Strong -Wall° Wood Shearwall Second -Story Walls - Stacked Application on Concrete Foundation6,7 Model No. Allowable Vertical Load, P (lb.)^ Seismic' Wind Allowable ASD Shear Load, V (lb.) Drift at Allowable Shear, A (in.) Allowable ASD Shear Load, V (lb.) Drift at Allowable Shear, A (in.) WSW18x9 2,000 1,225 0.42 1,345 0.48 WSW249 2,000 2,165 0.41 2,380 0.46 WSW18x10 2,000 1,125 0.47 1,235 0.53 WSW2410 2,000 1,990 0.46 2,190 0.52 WSW18x11 2,000 1,020 0.52 1,120 0.59 WSW2411 2,000 1,815 0.51 1,995 0.59 WSW18x12 2,000 920 0.57 1,010 0.64 WSW2412 2,000 1,640 0.57 1,805 0.65 See notes below. Strong -Wall" Wood Shearwall First -Story Walls - Stacked Application on Concrete Foundation9,11 StrongTie Model No. Allowable Vertical Load, P (lb.)' Stiffness Factor, Kx10° (lb. -in?) 2,500 psi Concrete 3,000 psi Concrete Seismic' Wind Seismic' Wind Allowable ASD Base Moment (Ib.-in.) Anchor Tension at Allowable ASD Base Moment (lb.)10 Allowable ASD Base Moment (Ib. in.) Anchor Tension at Allowable ASD Base Moment (lb.)10 Allowable ASD Base Moment (,b.-in.) Anchor Tension at Allowable ASD Base Moment (lb.)10 Allowable ASD Base Moment (lb. -in.) Anchor Tension at Allowable ASD Base Moment (lb.)10 WSW18x8 4,000 9.7 206,550 14.820 184,730 13,255 206,550 14,820 218,020 15,645 WSW24x8 4,000 19.4 413,565 21,840 423,540 22,365 413,565 21,840 455,060 24,030 WSW18x9 4,000 10.3 200.500 14,385 184,715 13,255 200,500 14,385 217,975 15,640 WSW249 4,000 21.5 411,000 21,705 423,525 22,365 411,000 21,705 452,050 23,870 WSW18x10 4.000 11.6 202,255 14,510 184,670 13,250 202.255 14,510 217,970 15,640 WSW24x10 4,000 22.6 389,855 20,585 423.505 22,365 389,855 20,585 429,135 22,660 WSW18x11 4,000 12.5 197,755 14,190 184,700 13,250 197,755 14,190 217,785 15,625 WSW2411 4,000 24.8 389,045 20,545 423,550 22,365 389,045 20,545 428.465 22,625 WSW18x12 4,000 12.8 189,275 13,580 184,755 13,255 189,275 13,580 208,345 14,950 WSW24x12 4,000 26.5 380,670 20,100 418,805 22,115 380,670 20,100 418,805 22,115 1. Allowable ASD base moments and anchor tension values are applicable to installations on concrete with specified compressive strengths as listed using the ASD basic (IBC Section 1605.3.1) or the alternative basic (IBC Section 1605.3.2) load combinations. 2. Load values include evaluation of bearing stresses on concrete foundations and do not require further evaluation by the Designer. For installations on masonry foundations, bearing capacity shall be evaluated by the Designer. 3. Seismic design based on 2015 IBC using R = 6.5. For other codes, use the seismic coefficients corresponding to light -frame bearing walls with wood structural panels or sheet -steel panels. 4. Allowable vertical load denotes the total maximum vertical load permitted on the panel acting in combination with the allowable shear load and base moment. 5. Allowable shear, drift, base moment and anchor tension values may be interpolated for intermediate height or vertical loads. 6. Two-story stacked panel combinations may consist of any height combination of equal width panels listed in these tables. 7. A multi -story kit (MSK) is required to attach the second -story panel to the first -story panel. 8. High -strength anchor bolts are required for anchor tension forces exceeding the allowable load for standard -strength bolts tabulated on pages 23-24. See pages 22-29 for WSW -AB anchor bolt information and anchorage solutions. 9. The Designer must verify that the cumulative overturning moment at the base of the first -story panel does not exceed the allowable base moment capacity as shown in the example on page 21. The overturning base moment shall be determined using the following equation: MOT = (Vi x hj) + (V2 x h2), where: MOT = Overturning base moment V1 = Applied shear load to first -story panel V2 = Applied shear load to second -story panel hi = Height of first -story panel; h2 = Total assembly Height (hi + Height of second -story panel + 5 in.) 10. Tabulated anchor tension values assume no resisting vertical load. Anchor tension loads at design shear values and including the effect of vertical load may be determined using the following equation: T = MOT / B - P/2, where: T = Anchor tension load (lb.) P = Applied vertical load (Ib.) MOT = Overturning moment, see Footnote 9 B = Moment arm (in.); 13.94" for WSW1 8,18.94" for WSW24 11. First -story panel drift must comply with code drift limits; evaluate drift at the top of the first -story panel using the following equation: A = h12 / K x [(3 x V2 x h3) + (2 x Vbase x hi)], where: A = First -story panel drift K = Stiffness factor for first -story panel hi = First -story panel height h3 = Second -story panel height V2 = Applied shear load to second -story panel Vbase = Sum of applied shear loads to first -story panel and second -story panel. 20 Two -Story Stacked on Concrete Foundations Designing for Cumulative Overturning Forces In multi -story structures, shear and the associated overturning forces due to seismic and wind requirements must be carried down to the foundation by the building's lateral -force resisting system. These forces are cumulative over the height of the building, and shear forces applied at the second or third levels of a structure will generate much larger base overturning moments than the same shears applied at the first story. V2=1,000 lb. If cumulative overturning is not considered, the design may result in forces several times higher than the capacity of the lower wall, anchor bolts and foundation anchorage. When specifying two-story stacked applications, analysis should be performed by following these steps. 1. Analyze the structure to determine the shear forces at each floor. The detail to the right illustrates the forces developed in a two-story stacked application. Then calculate the cumulative overturning moment (MOT), based on the story heights and applied shear forces at each story, as follows: MOT =(V1 xhi) +(V2xh2) 2. Select the first -story panel and ensure that the allowable base moment exceeds the overturning moment (MOT). 3. Check the applicable second -story panel with the same width as the first -story panel and verify that the allowable second -story shear force exceeds the applied second -story shear force. 4. Check the first -story panel drift. Drift Equation for First -Story Shearwalls The first -story panel drift must comply with code drift limits. Evaluate drift at the top of the first -story panel using the following equation: 2 A = (h1) (3V2h3 + 2Vbasehl) where: A = First -story panel drift (in.) K = Stiffness factor for first -story panel (lb.-in.2) h1 = First -story panel height (in.) h3 = Second -story panel height (in.) V1 = Applied shear load to first -story panel (lb.) V2 = Applied shear load to second -story panel (lb.) Vbase = V1 + V2 (lb.) Given Seismic, f'c = 2,500 psi First -story wall height = 9 ft. Second -story wall height = 8 ft. Joist height = 117/8 ft. First -story panel shear, V1 = 1,200 lb. Second -story panel shear, V2 = 1,000 lb. Solution 1. Calculate the overturning moment; MOT = (1,200 lb. x 105.25 in.) + (1,000 lb. x 213.25 in.) = 339,550 lb. -in. 2. Select WSW24x9 at the first -story; Mallow = 411,000 lb. -in. > MOT OK 3. Check the capacity of the second -story WSW24x9; Vallow = 2,165 lb. > V2 OK 4. Verify that the first -story drift does not exceed ASD code drift limit, Aallow = 0.7 (0.025H / Cd) = H / 228.6 Aallow = 105.25 in. / 228.6 = 0.46 in. A _ (105.25 1-)2 I(3 x 1,000 lb. x 103") + (2 x 2,200 lb. x 105.25")] 21.5 x 109 WSW24x9 V1=1,200 lb. WSW24x9 MOT Design Example Strong -Tie M h2 = 2131/4" A = 0.40 in. < Aallow OK 21 Anchorage Solutions WSW -AB Anchor Bolts WSW -AB anchor bolts in 7/8" and 1 " diameters offer flexibility to meet specific project demands. Inspection is easy; the head is stamped with a "No Equal" symbol for identification, bolt length, bolt diameter, and optional "HS" for "High Strength" if specified. Material: ASTM F1554 Grade 36; High Strength (HS) ASTM A449 An additional nut for template installation is provided with each WSW -AB. Strong -Wall Wood Shearwall Width (in.) 12 and 18 Model No. Dia. (in.) Total Length (in) le (in.) WSW-AB'/8x24 7/8 24 20 WSW-AB'/8x24HS 7/8 24 20 WSW-AB7/8x30 7/8 30 26 WSW-AB7/8x30HS 7/8 30 26 WSW-AB'/8x36HS 7/8 36 32 24 WSW-A131x24 1 24 20 WSW-AB1x24HS 1 24 20 WSW-AB1x30 1 30 26 WSW-AB1 x30HS 1 30 26 WSW-A61 x36HS 1 36 32 WSW-HSR Extension Kit WSW-HSR allows for anchorage in tall stemwall applications where full embedment of a WSW -AB into the footing is required. The head is stamped for identification like a WSW -AB. Kit includes ASTM A449 high -strength rod with heavy hex nut fixed in place and high -strength coupler nut. Do not use in place of WSW -AB. Strong -Wall Total Wood Shearwall Model No. Dia. Length le Width (in.) (in) (in.) (in.) WSW-HSR'/ax24KT 7/8 24 22 12 and 18 WSW-HSR'/ax36KT 7/8 36 34 WSW-HSR1x24KT 1 24 22 24 WSW-HSR1x36KT 1 36 34 Total le = WSW-HSR le + WSW -AB le + 21/8" '/a" 24 HS Top of O concrete � Heavy hex nut CD fixed in place on all WSW -AB anchor bolts. le Heavy hex nut Plate washer O Heavy hex nut WSW -AB HX on 7/8 P4 21/8" extension HX kit Top of O concrete Heavy hex nut fixed in place. J 7/8" or 1" le High -strength _ rod High - strength _ coupler O nut IF WSW-HSRXXKT Strong -Tie Top of concrete 0 WSW-HSR —► le Cut to length No as necessary. High -strength coupler nut O O 2l11/8" 1 O WSW -AB le O WSW-HSR and WSW -AB Assembly 22 Anchorage Solutions Strong -Tie Strong -Wall® Wood Shearwall Tension Anchorage Solutions - 2,500 psi Concrete' 5,6 Design Criteria Concrete Condition Anchor Strength' WSW-AB7/s Anchor Bolt WSW-AB1 Anchor Bolt ASD Allowable Tension (lb.) W (in.) de (in.) ASD Allowable Tension (lb.) W (in.) de (in.) Cracked Standard 11,900 27 9 16,100 33 11 13,100 29 10 17,100 35 12 High Strength 24,900 43 15 33,000 51 17 27,100 46 16 35,300 54 18 Seismic3 Uncracked Standard 12,500 24 8 15,700 28 10 13,100 25 9 17,100 30 1 10 High Strength 25,300 38 13 32,300 44 15 27,100 40 14 35,300 47 16 Cracked Standard 5,100 14 6 6,200 16 6 8,700 20 7 11,400 24 8 13,100 27 9 17,100 32 11 High Strength 15,900 30 10 21,100 36 12 18,400 33 11 27,300 42 14 23,100 38 13 31,800 46 16 27,100 42 14 35,300 50 17 Wind Uncracked Standard 5,000 12 6 6,400 14 6 9,300 18 6 12,500 22 8 13,100 23 8 1 17,100 28 10 High Strength 15,200 25 9 21,900 32 11 19,900 30 10 26,400 36 12 24,000 34 12 31,500 40 14 27,100 37 13 35,300 43 15 Strong -Wall® Wood Shearwall Tension Anchorage Solutions - 3,000 psi Concrete' 5,6 Design Criteria Concrete Condition Anchor Strength' WSW-AB7/a Anchor Bolt WSW-ABi Anchor Bolt ASD Allowable Tension (lb.) W (in.) de (in.) ASD Allowable Tension (lb.) W (in.) de (in.) Cracked Standard 12,300 26 9 16,000 31 11 13,100 28 10 17,100 33 11 High Strength 25,200 41 14 32,700 48 16 27,100 43 15 35,300 51 17 Seismic3 Uncracked Standard 12,000 22 8 16,300 27 9 13,100 24 8 17,100 28 10 High Strength 25,300 36 12 32,700 42 14 27,100 38 13 35,300 44 15 Cracked Standard 5,000 13 6 5,600 14 6 8,800 19 7 10,200 21 7 13,100 25 9 17,100 30 10 High Strength 15,700 28 10 20,100 33 11 19,200 32 11 25,300 38 13 23,200 36 12 32,300 44 15 27,100 40 14 35,300 47 16 Wind° Uncracked Standard 5,500 12 6 6,200 13 6 8,500 16 6 12,800 21 7 13,100 22 8 17,100 26 9 High Strength 16,600 25 9 21,800 30 10 19,700 28 10 25,200 33 11 24,000 32 11 31,700 38 13 27,100 35 12 35,300 41 14 See footnotes on page 24. 23 Anchorage Solutions Strong -Tie 0 Strong -Wall® Wood Shearwall Tension Anchorage Solutions - 4,500 psi Concrete' 5,6 Design Criteria Concrete Condition Anchor Strength' WSW-AB7/e Anchor Bolt WSW-AB1 Anchor Bolt W (in.) de (in.) ASD Allowable Tension (lb.) W (in.) de (in.) ASD Allowable Tension (lb.) Cracked Standard 12,600 23 8 16,000 27 9 13,100 24 8 17,100 29 10 High Strength 24,800 36 12 32,100 42 14 27,100 38 13 35,300 45 15 Seismic3 Uncracked Standard 12,700 20 7 15,700 23 8 13,100 21 7 17,100 25 9 High Strength 24,600 31 11 32,500 37 13 27,100 34 12 35,300 39 13 Cracked Standard 5,400 12 6 6,800 14 6 8,300 16 6 11,600 20 7 13,100 22 8 17,100 26 9 High Strength 15,300 24 8 21,400 30 10 19,300 28 10 25,800 34 12 23,600 32 11 31,000 38 13 27,100 36 12 35,300 42 14 Wind^ Uncracked Standard 6,800 12 6 6,800 12 6 9,400 15 6 12,400 18 6 13,100 19 7 17,100 23 8 High Strength 16,800 22 8 21,600 26 9 20,300 25 9 26,700 30 10 24,100 28 10 32,200 34 12 27,100 31 11 35,300 36 12 1. Anchorage designs conform to ACI 318-14 and ACI 318-11 Appendix D with no supplementary reinforcement for cracked and uncracked concrete as noted. 2. Anchor strength indicates required grade of WSW -AB anchor bolt. Standard (ASTM F1554 Grade 36) or high strength (HS) (ASTM A449). 3. Seismic indicates Seismic Design Categories C through F. Detached one- and two-family dwellings in SDC C may use wind anchorage solutions. Seismic anchorage designs conform to ACI 318-14 Section 17.2.3.4.3 and ACI 318-11 Section D.3.3.4. 4. Wind includes Seismic Design Categories A and B and detached one- and two-family dwellings in SDC C. 5. Foundation dimensions are for anchorage only. Foundation design (size and reinforcement) by others. The registered design professional may specify alternative embedment, footing size or anchor bolt. 6. Refer to slab on grade, curb, stemwall and interior footing details for w and de as shown on pages 26-27. 24 Anchorage Solutions Strong -Wall° Wood Shearwall Shear Anchorage Foundation shear reinforcement to resist shear forces from Strong -Wall® Wood Shearwalls located at the edge of concrete is shown in the table below. The WSW12 used in wind applications does not require shear reinforcement when the panel design shear force is less than the anchorage allowable shear load shown in the table below. Strong -Wall® Wood Shearwall Shear Anchorage Solutions Strong -Tie Seismic' Wind' Strong -Wall Lt(inor h Wood Shearwall ) Shear Minimum Curb/ Shear Minimum Curb/ ASO Allowable Shear Load, V (lb.)6 Model Reinforcement Stemwall Width (in.) Reinforcement Stemwall Width (in.) Uncracked Cracked WSW12 101/4 (1) #3 Hairpin 85 See Note 6 6 1,035 740 WSW18 15 (1) #3 Hairpin 85 (1) #3 Hairpin 6 Hairpin reinforcement achieves maximum allowable shear load of the Strong -Wall® WSW. WSW24 19 (2) #3 Hairpin 85 (1) #3 Hairpin 6 1. Shear anchorage designs conform to ACI 318-14 and assume minimum 2,500 psi concrete. See pages 23-24 for tension anchorage. 2. Shear reinforcement is not required for interior foundation applications (panel installed away from edge of concrete), or braced -wall panel applications. 3. Seismic indicates Seismic Design Categories C through F. Detached one- and two-family dwellings in SDC C may use wind anchorage solutions. Seismic shear reinforcement designs conform to ACI 318-14 Section 17.2.3.5.3. 4. Wind includes Seismic Design Categories A and B. 5. Where noted, minimum curb/stemwall width is 6" when standard -strength anchor bolt is used. 6. Use (1) #3 tie for WSW12 when panel design shear force exceeds tabulated anchorage allowable shear load. 7. 94 grade 40 shear reinforcement may be substituted for WSW shear anchorage solutions. 8. The registered design professional may specify alternative shear anchorage. � Lh Min. Lt 4"Min. 3" 1 I WSW -AB #3 Hairpin Field tie and secure during grade 60 rebar concrete placement. Overlap (Min.) varies with bolt spacing. Hairpin Shear Reinforcement 11/2" CLR WSW -AB WSW -AB #3 Tie Field tie and secure grade 60 during concrete rebar (Min.) placement. #3 Hairpin (#3 tie similar), see table for required quantity. Hairpin Installation (Garage curb shown, other footing types similar) Tie Shear Reinforcement 25 Anchorage Solutions Curb or Stemwall Installation WSW -AB Minimum curb/stemwall width per page 25. 21/s" _ Shear reinforcement per page 25 when required. de a as T IIIIII a 5" min. for , WSW-ABI/s /z W /2 W 6" min. for W 10 WSW-AB1. Curb or Stemwall Section View Slab -on -Grade Installation WSW-AB� Shear reinforcement per page 25 when 21/8required. d H a de 5" min. for WSW-AB7/a , /z W /z W 6" min. for W� WSW-AB1. Slab -on -Grade Section View Brick Ledge Installation Perspective View (Slab not shown for clarity) Perspective View Strong -Tie r- — — — — — — — — — — — - Y2 W I � I � W I � I � t/2 W I � I � ------------- f%z Footing Plan ---- T Y2 W I � I � W I � I � I I t/2 W I Ifs W--.- 7;2W� Footing Plan WSW -AB Minimum curb/stemwall width per page 25. 2t/8' Shear reinforcement f per page 25 when H required.---------------------------, as ° a i Y2W j a i W 5" min. for I --------- WSW-AB'/s �t/zW YzW--►---------- ------ - 6" min. for - W = �—Y2 W t/2 W--� WSW-AB1. Brick Ledge Section View Perspective View Footing Plan Anchorage Solutions General Notes 1.The Designer may specify alternate embedment, footing size or bolt grade. Foundation design (size and reinforcement) by Designer. 2. Footing dimensions and rebar requirements are for anchorage only. 26 U Z } Z a 0 O U w F7 O Z 0 0 Z 0 CO CO s CO 3 3 J U Anchorage Solutions Interior Installation WSW -AB d ° N a de . 5" min. for WSW-AB�,/z W 7/s 6" min. for . W WSW-AB1. Interior Section View --------------------------- I , -------- �/2 W I I ' W W '---------------- ' ---- ------ Y2 W Yz W '� Footing Plan Strong -Tie Stemwall Extension Installation Minimum stemwall width per page 25. I �temwallil—�!—�� Height h=h=11 (WSW -AB le + =1I 1=1 11= WSW-HSR le+ III 11-11 21/a"- de) II II _I See page 22 for=11-111- le dimensions. T71 1T=1 -II=III= I I -I II I III -III- u de 1 h Anchorage Solutions General Notes 1. The Designer may specify alternate embedment, footing size or bolt grade. 2. Footing dimensions and rebar requirements are for anchorage only. Strong Mal l° Wood Shearwall Anchor Bolt Layout Wall Distance from Center Model to Center of WSW-ABs S (in.) WSW12 8Ye WSW 8 14 WSW24 20 d T III elll=ll 5" min. for WSW-AB7/a '/2 W M 6" min. for WSW-HSR Shear reinforcement per page 25 when required. a IIIih=� II ' ' ° 11111111 W Min WSW-AB1. W;I Section at Stemwall WSW -AB and WSW-HSR Extension Application 2" S� 3�z WSW Plan View Anchorage Graphic WSW -AB 27 Anchorage Solutions Anchor Reinforcement Solutions on Grade Beams Simpson Strong Tie now provides grade -beam anchorage solutions for the Strong -Wall® Wood Shearwall (WSW), which have been calculated to conform to ACI 318-14. Through funding from the Structural Engineers Association of Northern California, initial testing at Scientific Construction Laboratories Inc. confirmed the need to comply with ACI 318 requirements to prevent plastic hinging at anchor locations. Follow-on testing at the Simpson Strong Tie Tyrell Gilb Research Laboratory was then used to confirm these findings and validate performance. The testing consisted of specimens with closed -tie anchor reinforcement, specimens with non -closed u-stirrups, and control specimens without anchor reinforcement. Flexural and shear reinforcement were designed to resist amplified anchorage forces and compared to test beams designed for non -amplified strength level forces. The test program has proven the performance of the anchor reinforcement details developed by Simpson Strong Tie. Significant Findings from Testing: Grade -beam flexural and shear capacity is critical to anchor performance and must be designed to exceed the demands created by the attached structure. In wind load applications, this demand includes the factored demand from the Strong -Wall Wood Shearwall (WSW). In seismic applications, testing and analysis have shown that in order to achieve the anchor performance expected by ACI 318 Anchorage design methodologies, the concrete member design strength needs to resist the amplified anchor design demand from ACI 318-14 Section 17.2.3.4.3 and ACI 318-11 Appendix D Section D.3.3.4.3. To help Designers achieve this, Simpson Strong Tie recommends Designers apply the seismic design moment listed in the table below at the WSW location when evaluating the grade -beam design strength under seismic loads. The tabulated moment correlates to the lowest of the anchor -tension design limits defined in the sections listed above as they relate to each WSW model. Closed -tie anchor reinforcement is critical to maintain the integrity of the reinforced core where the anchor is located. Testing with u-stirrups that did not include complete closed ties showed premature splitting failure of the grade beam. Grade -Beam Testing Strong -Wall® Wood Shearwall Grade -Beam Anchorage Solutions Strong -Tie Anchor Reinforcement Amplified LRFD Applied Design Strong -Wall Anchor for Wind and Seismic3,8,e Seismic Moment (ft.-Ib.)°,5,6,7 Wood Shearwall Anchor Bolt Diameter Standard Strength High Strength Standard Strength High Strength Model Model No. (in.) WSW -AB (HS) WSW -AB WSW -AB (HS) WSW -AB WSW12 24,700 24,700 WSW-AB'/a WSW-AB7/sHS 1/8Closed (4) #4 Ties / Wall (6) #4 Closed Ties / Wall WSW18 44,100 50,600 WSW24 WSW-AB1 1 (2) #4 (4) #4 75,600 93.600 WSW-AB1 HS Closed Ties / Anchor Closed Ties / Anchor 1. Anchor reinforcement conforms to ACI 318-14 Section 17.4.2.9 and ACI 318-11 Section D.5.2.9. Full-scale testing was used to validate anchor reinforcement configuration and placement. 2. Minimum concrete compressive strength, f'c = 2,500 psi. 3. Closed -tie anchor reinforcement to be ASTM A615 Grade 60 (min.) #4 rebar. 4. Grade -beam longitudinal and tie reinforcement shall be specified by the registered design professional for flexure and shear loading. Design should consider project -specific design loads and allowable soil pressure. 5. Simpson Strong Tie recommends using the tabulated minimum amplified LRFD applied seismic design moment to ensure grade -beam design flexure and shear strength is adequate to prevent plastic hinge formation under demands associated with anchorage forces corresponding to ACI 318-14 Section 17.2.3.4.3 and ACI 318-11 Section D.3.3.4.3. 6. Designer may use reduced moment due to applied WSW lateral load. Minimum moment shall be the lesser of the tabulated moment or the amplified LRFD design moment for seismic: (ASD design demand shear/0.7) x 00 x WSW wall height for grade -beam design. 7. Minimum grade -beam design moment for wind and seismic in Seismic Design Category A and B and detached one- and two-family dwellings in SDC C: (ASD design demand shear/0.6) x WSW wall height. 8. Closed tie may be single -piece hoop or two-piece assembly with a u-stirrup with standard 135-degree hooks and a top cross -tie cap. See detail 6/WSW 1.1. 9. See details for grade -beam anchor reinforcement placement, installation and spacing requirements. Closed -tie anchor reinforcement quantity is per wall for the 12"- and 18"-wall models, and per anchor for the 24" model. 28 Anchor -Bolt Templates Simpson Strong Tie has developed a reusable anchor -bolt template for common foundation types for the Strong -Wall® Wood Shearwalls. The templates help to accurately locate the newly -designed WSW -AB preassembled anchor bolts, which simplifies installation and greatly reduces the chances of voids in the concrete. Strong -Wall° Wood Shearwall Anchor -Bolt Templates Strong -Wall Wood Shearwall Model No. Width (�n') Strong -Wall Wood Shearwall Template Model Reversible Panel Form Brick Ledge WSW12 121/8 WSW-RT12 WSW-RTPF12 WSW-RTBL12 WSW18 18 WSW-RT18 WSW-RTPF18 WSW-RTBL18 WSW24 24 WSW-RT24 WSW-RTPF24 WSW-RTBL24 1. Templates are recommended and are required in some jurisdictions. 2. Foundation design by the Designer. Top of concrete WSW-RTPF (Panel form) U.S. Patent 7,445,192 An additional nut for template installation is provided with each WSW -AB. ® WSW-RT Exterior Installation* U.S. Patent 7,445,192 WSW-RTBL (Brick ledge) U.S. Patent 7,445,192 Strong -Tie M Anchor Bolt Height WSW-RT Interior Installation* U.S. Patent 7,445,192 *WSW-RT templates are reversible. Use the same template for interior or exterior applications. 29 Installation Details Anchorage and Installation Details Simpson Strong Tie offers complete structural details in order to make the specification and installation easier for the Strong -Wall° Wood Shearwalls. Versions of these details are available three ways: • Online at strongtie.com: Full-size 24" x 36" detail sheets may be downloaded at strongtie.com in DWG, DXF and PDF formats. • Call (800) 999-5099: Full-size, printed sheets may be requested from our regional branches at no charge. • In this catalog: Smaller versions are shown here for easy reference. Details are numbered to coincide with full-size sheets, although some have been left out to eliminate redundancy. In This Section: Strong -Wall° Wood Shearwall Anchorage and Installation Details Pages 31-47 (Sheets WSW1, WSW1.1, WSW2, WSW3 and WSW4) �eayi wo-k'.r mhs •.a KM�o..v.a ,IS PVT" Ri59Tt w0 YJQQIE6Y,CYoili tifYldM\AQ e � I �a+nv aw ■rmnw a.R+axo•�r b KUII�f 30 Strong -Tie ; [rar.-g-Wm Wood 25- earr,ra i s ko- 4 u N�m E ,tri'�MI�aa'ti`jrYS�o! 3}:�wV�,S ryw 3Mr�rnn TO* ['' � "I Rill mob wma PD—iw P-W0 rro� YV"m kLWod D oa. r ;3 1.a ,eo-ad �dd a` oy a r 1 F -4� [7 ndd. rt � kwx .mvnor x+o-raxe d Vw MI '+* sNw M . ,Z S�^-ppJ,L IZ KOB ONGRAN FMM ur1FR,ORfA,NtIAN Installation Details 21V H de 5" MIN. FOR WSW-AB7/8 6" MIN FOR WSW-AB1 2% de 5" MIN. FOR WSW-AB7/8 6" MIN FOR WSW-A61 WSW -AB - SHEAR REINFORCEMENT PER 5/WSW1 WHEN REQUIRED. 2HH de 5" MIN. FOR WSW-A67/8 6" MIN FOR WSW-AB1 SLAB ON GRADE FOUNDATION Strong -Tie WSW -AB MINIMUM CURB/STEMWALL WIDTH PER 5/WSW1. SHEAR REINFORCEMENT PER 5/WSW1 WHEN REQUIRED. da i a d da 1/2 W 1/2 W W CURB OR STEMWALL FOUNDATION REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. %AimALA Q INTERIOR FOUNDATION WSW -AB MINIMUM CURB/STEMWALL WIDTH PER 5/WSW1. 2% SHEAR REINFORCEMENT PER 5/WSW1 WHEN REQUIRED. H de ME ° d 5" MIN. FOR f ° WSW-AB7/8 ME 6" MIN FOR ° WSW-A61 1/2 W 1/2 W W BRICK LEDGE FOUNDATION NOTES: 1. SEE 2/WSW1 FOR DIMENSIONS AND ADDITIONAL NOTES. 2. SEE 5/WSW1 FOR SHEAR REINFORCEMENT WHEN REQUIRED. 3. MAXIMUM H = I,- de. SEE 3/WSW1 AND 4/WSW1 FOR le. STRONG -WALL° WOOD SHEARWALL - TYPICAL SECTIONS 1 /WSW1 31 Installation Details Strong -Tie 0 SIMPSON STRONG -WALL SLAB OR CURB AND WOOD SHEARWALL SURROUNDING FOUNDATION NOT SHOWN FOR CLARITY 1 W %2 W WSW -AB %2 W I I %2 W SEE TABLE BELOW FOR DIMENSIONS FOUNDATION PLAN VIEW WSW ANCHORAGE SOLUTIONS FOR 2,500 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB7/8 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE TENSION (Ib.) W (in.) de (in.) ASD ALLOWABLE TENSION (Ib.) W (in.) de (in.) CRACKED STANDARD 11,900 27 9 16,100 33 11 13,100 29 10 17,100 35 12 HIGH STRENGTH 24,900 43 15 33,000 51 17 27,100 46 16 35,300 54 18 SEISMIC UNCRACKED STANDARD 12,500 24 8 15,700 28 10 13,100 25 9 17,100 30 10 HIGH STRENGTH 25,300 38 13 32,300 44 15 27,100 40 14 35,300 47 16 CRACKED STANDARD 5,100 14 6 6,200 16 6 8,700 20 7 11,400 24 8 13,100 27 9 17,100 32 11 HIGH STRENGTH 15,900 30 10 21,100 36 12 18,400 33 11 27,300 42 14 23,100 38 13 31,800 46 16 27,100 42 14 35,300 50 17 WIND UNCRACKED STANDARD 5,000 12 6 6,400 14 6 9,300 18 6 12,500 22 8 13,100 23 8 17,100 28 10 HIGH STRENGTH 15,200 25 9 21,900 32 11 19,900 30 10 26,400 36 12 24,000 34 12 31,500 40 14 27,100 37 13 35,300 43 15 NOTES: 1. ANCHORAGE DESIGNS CONFORM TO ACI 318-11 APPENDIX D AND ACI 318-14 WITH NO SUPPLEMENTARY REINFORCEMENT FOR CRACKED OR UNCRACKED CONCRETE AS NOTED. 2. ANCHOR STRENGTH INDICATES REQUIRED GRADE OF WSW -AB ANCHOR BOLT. STANDARD (ASTM F1554 GRADE 36) OR HIGH STRENGTH (HS) (ASTM A449). 3. SEISMIC INDICATES SEISMIC DESIGN CATEGORY C - F. DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C MAY USE WIND ANCHORAGE SOLUTIONS. SEISMIC ANCHORAGE DESIGNS CONFORM TO ACI 318-11 SECTION D.3.3.4.3 AND ACI 318-14 SECTION 17.2.3.4.3. 4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C. 5. FOUNDATION DIMENSIONS ARE FOR ANCHORAGE ONLY. FOUNDATION DESIGN (SIZE AND REINFORCEMENT) BY OTHERS. THE REGISTERED DESIGN PROFESSIONAL MAY SPECIFY ALTERNATE EMBEDMENT, FOOTING SIZE OR ANCHOR BOLT. 6. REFER TO1/WSW1 FOR de. STRONG -WALL° WOOD SHEARWALL TENSION ANCHORAGE SCHEDULE F2/WSW1 32 Installation Details WSW ANCHORAGE SOLUTIONS FOR 3,000 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB7/8 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE TENSION (Ib.) W (in.) de (in.) ASD ALLOWABLE TENSION (Ib.) W (in.) de (in.) CRACKED STANDARD 12,300 26 9 16,000 31 11 13,100 28 10 17,100 33 11 HIGH STRENGTH 25,200 41 14 32,700 48 16 27,100 43 15 35,300 51 17 SEISMIC UNCRACKED STANDARD 12,000 22 8 16,300 27 9 13,100 24 8 17,100 28 10 HIGH STRENGTH 25,300 36 12 32,700 42 14 27,100 38 13 35,300 44 15 CRACKED STANDARD 5,000 13 6 5,600 14 6 8,800 19 7 10,200 21 7 13,100 25 9 17,100 30 10 HIGH STRENGTH 15,700 28 10 20,100 33 11 19,200 32 11 25,300 38 13 23,200 36 12 32,300 44 15 27,100 40 14 35,300 47 16 WIND UNCRACKED STANDARD 5,500 12 6 6,200 13 6 8,500 16 6 12,800 21 7 13,100 22 8 17,100 26 9 HIGH STRENGTH 16,600 25 9 21,800 30 10 19,700 28 10 25,200 33 11 24,000 32 11 31,700 38 13 27,100 35 12 35,300 41 14 WSW ANCHORAGE SOLUTIONS FOR 4,500 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB7/8 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE TENSION (Ib.) W (in.) de (in.) ASD ALLOWABLE TENSION (Ib.) W (in.) de (in.) CRACKED STANDARD 12,600 23 8 16,000 27 9 13,100 24 8 17,100 29 10 HIGH STRENGTH 24,800 36 12 32,100 42 14 27,100 38 13 35,300 45 15 SEISMIC UNCRACKED STANDARD 12,700 20 7 15,700 23 8 13,100 21 7 17,100 25 9 HIGH STRENGTH 24,600 31 11 32,500 37 13 27,100 34 12 35,300 39 13 CRACKED STANDARD 5,400 12 6 6,800 14 6 8,300 16 6 11,600 20 7 13,100 22 8 17,100 26 9 HIGH STRENGTH 15,300 24 8 21,400 30 10 19,300 28 10 25,800 34 12 23,600 32 11 31,000 38 13 27,100 36 12 35,300 42 14 WIND UNCRACKED STANDARD 6,800 12 6 6,800 12 6 9,400 15 6 12,400 18 6 13,100 19 7 17,100 23 8 HIGH STRENGTH 16,800 22 8 21,600 26 9 2O,300 25 9 26,700 30 10 24,100 28 10 32,200 34 12 27,100 31 11 35,300 36 12 NOTES: 1. ANCHORAGE DESIGNS CONFORM TO ACI 318-11 APPENDIX D AND ACI 318-14 WITH NO SUPPLEMENTARY REINFORCEMENT FOR CRACKED OR UNCRACKED CONCRETE AS NOTED. 2. ANCHOR STRENGTH INDICATES REQUIRED GRADE OF WSW -AB ANCHOR BOLT. STANDARD (ASTM F1554 GRADE 36) OR HIGH STRENGTH (HS) (ASTM A449). 3. SEISMIC INDICATES SEISMIC DESIGN CATEGORY C - F. DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C MAY USE WIND ANCHORAGE SOLUTIONS. SEISMIC ANCHORAGE DESIGNS CONFORM TO ACI 318-11 SECTION D.3.3.4.3 AND ACI 318-14 SECTION 17.2.3.4.3. 4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C. 5. FOUNDATION DIMENSIONS ARE FOR ANCHORAGE ONLY. FOUNDATION DESIGN (SIZE AND REINFORCEMENT) BY OTHERS. THE REGISTERED DESIGN PROFESSIONAL MAY SPECIFY ALTERNATE EMBEDMENT, FOOTING SIZE OR ANCHOR BOLT. 6. REFER TO 1/WSW1 FOR de. Strong -Tie STRONG -WALL° WOOD SHEARWALL TENSION ANCHORAGE SCHEDULE 2/WSW1 33 Installation Details 3" Lh MIN #3 HAIRPIN, GRADE 60 REBAR (MIN.) FIELD TIE AND SECURE DURING CONCRETE PLACEMENT. OVERLAP VARIES WITH BOLT SPACING. ANCHOR BOLT HAIRPIN SHEAR REINFORCEMENT flcANCHOR BOLT r A #3 HAIRPIN (#3 TIE SIMILAR). 1Yz" CLR SEE TABLE FOR REQUIRED I FQUANTITY. I �A HAIRPIN INSTALLATION (GARAGE CURB SHOWN. OTHER FOOTING TYPES SIMILAR.) 3" Strong -Tie Lt 4" MIN #3 TIE, GRADE 60 REBAR (MIN.) FIELD TIE AND SECURE DURING CONCRETE PLACEMENT. ANCHOR BOLT TIE SHEAR REINFORCEMENT 1Y" ANCHOR BOLT #3 HAIRPIN (#3 TIE SIMILAR). SEE TABLE FOR REQUIRED QUANTITY. SECTION A -A REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. STRONG -WALL® WOOD SHEARWALL SHEAR ANCHORAGE SEISMIC3 WIND 4 Lt OR MINIMUM MINIMUM ASD ALLOWABLE SHEAR LOAD, MODEL Lh SHEAR CURB/ SHEAR CURB/ V (Ib.) 5 (in.) REINFORCEMENT STEMWALL REINFORCEMENT STEMWALL UNCRACKED CRACKED WIDTH (in.) WIDTH (in.) WSW12 10Y4 (1) #3 HAIRPIN 85 SEE NOTE 6 6 1035 740 WSW18 15 (1) #3 HAIRPIN 85 (1) #3 HAIRPIN 6 HAIRPIN REINFORCEMENT ACHIEVES MAXIMUM ALLOWABLE SHEAR LOAD OF THE WSW WSW24 19 (2) #3 HAIRPINS 85 (1) #3 HAIRPIN 6 NOTES: 1. SHEAR ANCHORAGE DESIGNS CONFORM TO ACI 318-11 AND ACI 318-14 AND ASSUME MINIMUM 2,500 PSI CONCRETE. 2. SHEAR REINFORCEMENT IS NOT REQUIRED FOR INTERIOR FOUNDATION APPLICATIONS (PANEL INSTALLED AWAY FROM EDGE OF CONCRETE), OR BRACED WALL PANEL APPLICATIONS. 3. SEISMIC INDICATES SEISMIC DESIGN CATEGORY C THROUGH F. DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C MAY USE WIND ANCHORAGE SOLUTIONS. 4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C. 5. WHERE NOTED, MINIMUM CURB/STEMWALL WIDTH IS 6 INCHES WHEN STANDARD STRENGTH ANCHOR BOLT IS USED. 6. USE (1) #3 TIE FOR WSW12 WHEN PANEL DESIGN SHEAR FORCE EXCEEDS TABULATED ANCHORAGE ALLOWABLE SHEAR LOAD. 7. #4 GRADE 40 SHEAR REINFORCEMENT MAY BE SUBSTITUTED FOR WSW SHEAR ANCHORAGE SOLUTIONS. STRONG -WALL° WOOD SHEARWALL SHEAR ANCHORAGE SCHEDULE AND DETAILS F5/WSW1 34 Installation Details PLACE ANCHOR REINFORCEMENT WHERE INDICATED BASED ON REQUIRED QUANTITY (EX. 2 TIES REQUIRED: PLACE AT LOCATIONS MARKED 1 AND 2) TAB �f11 B�1e1 Btl�� IpNfl f1�R�, SHEAR REINFORCEMENT PER 5/WSW1 WHEN REQUIRED CONTINUOUS GRADE BEAM TOP AND BOTTOM REINFORCEMENT BY REGISTERED DESIGN PROFESSIONAL GRADE BEAM SHEAR TIE REINFORCEMENT BY REGISTERED DESIGN PROFESSIONAL PLACE ANCHOR REINFORCEMENT WHERE INDICATED BASED ON REQUIRED QUANTITY 5 1 3 4 2 8 (EX. 2 TIES REQUIRED: PLACE AT LOCATIONS MARKED 1 AND 2) WSW-7/8AB WSW-71BABHS SHEAR REINFORCEMENT PER 5ANSW7 WHEN REQUIRED CONTINUOUS GRADE BEAM TOP AND BOTTOM REINFORCEMENT ° BV REGISTERED DESIGN PROFESSIONAL GRADE BEAM SHEAR TIE REINFORCEMENT BY REGISTERED ° DESIGN PROFESSIONAL PER TABLE GRADE BEAM ELEVATION AT GRADE BEAM ELEVATION AT 1/WSW1.1 2/WSW1.1 24" WALL MODEL 12" AND 18" WALL MODELS NOTE: WSW -AB ANCHOR REINFORCEMENT SHEAR REINFORCEMENT PER OPTIONAL IS FOR ANCHORAGE ONLY. 5/WSW1 WHEN REQUIRED COLD JOINT GRADE BEAM DESIGN (SIZE AND REINFORCEMENT) BY REGISTERED DESIGN PROFESSIONAL. - OPTIONAL - COLD JOINT CLOSED TIE ANCHOR REINFORCEMENT PER TABLE. - GRADE BEAM SHEAR TIE h t REQUIRED 10" WIDTH MAY DIFFER FROM GRADE REINFORCEMENT BY REGISTERED BEAM SHEAR TIE REINFORCEMENT WIDTH THAT IS DESIGN PROFESSIONAL D 16" i Y2, DESIGNED BY REGISTERED DESIGN PROFESSIONAL. D LOCATE CONTINUOUS BAR AT EACH CORNER OF CONTINUOUS GRADE BEAM ANCHOR REINFORCEMENT TOP AND BOTTOM REINFORCEMENT BY REGISTERED DESIGN PROFESSIONAL CONTINUOUS GRADE BEAM TOP AND BOTTOM REINFORCEMENT BY REGISTERED DESIGN PROFESSIONAL 10" ANCHOR REIN. NOTE: W DIMENSIONING NOTES: W MINIMUM DISTANCES D: DEPTH BY REGISTERED DESIGN DIMENSIONING NOTES: FROM THE ANCHOR BOLT PROFESSIONAL (24" MIN). D: DEPTH BY REGISTERED DESIGN PLATE WASHER TO TOP W: WIDTH BY REGISTERED DESIGN PROFESSIONAL (24" MIN). AND BOTTOM OF CLOSED PROFESSIONAL (18" MIN). W: WIDTH BY REGISTERED DESIGN TIE REINFORCEMENT ARE PROFESSIONAL (18" MIN). 13" AND 5" RESPECTIVELY. GRADE BEAM SECTION AT GRADE BEAM SECTION AWAY 3/WSW1.1 4/WSW1.1 ANCHOR REINFORCEMENT FROM ANCHOR REINFORCEMENT WSW GRADE BEAM ANCHOR REINFORCEMENT ANCHOR REINFORCEMENT AMPLIFIED LRFD APPLIED DESIGN STRONG -WALL ANCHOR ANCHOR FOR WIND AND SEISMIC'- SEISMIC MOMENT (f[.-Ibs.)°5�s,7 WOOD SHEARWALL WIDTH (in.) MODEL NO. DIAMETER (in.) STANDARD HIGH STRENGTH STANDARD HIGH STRENGTH STRENGTH WSW -AB (HS) WSW -AB STRENGTH WSW -AB (HS) WSW -AB 12" MODEL WSW-AB7/8 WSW-AB718HS 7/8 4-#4 CLOSED TIES PER 2e 6-#4 CLOSED TIES PER e 24,700 24,700 18" MODEL 44,100 50,600 24" MODEL WSW-AB1 1 2-#4 CLOSED TIES PER e 4-#4 CLOSED TIES PER we 75,600 93,600 WSW-AB1HS NOTES: 1. ANCHOR REINFORCEMENT CONFORMS TO ACI 318-14 SECTION 17.4.2.9 AND ACI 318-11 SECTION D.5.2.9. FULL-SCALE TESTING WAS USED TO VALIDATE ANCHOR REINFORCEMENT CONFIGURATION AND PLACEMENT. 2. MINIMUM CONCRETE COMPRESSIVE STRENGTH, Pc = 2500 psi. 3. CLOSED TIE ANCHOR REINFORCEMENT TO BE ASTM A615 GRADE 60 (MIN) #4 REBAR. 4. GRADE BEAM LONGITUDINAL AND TIE REINFORCEMENT SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL FOR FLEXURE AND SHEAR LOADING. DESIGN SHOULD CONSIDER PROJECT SPECIFIC DESIGN LOADS AND ALLOWABLE SOIL PRESSURE. 5. SIMPSON STRONG -TIE RECOMMENDS USING THE TABULATED MINIMUM AMPLIFIED LRFD APPLIED SEISMIC DESIGN MOMENT TO ENSURE GRADE BEAM DESIGN FLEXURE AND SHEAR STRENGTH ARE ADEQUATE TO PREVENT PLASTIC HINGE FORMATION UNDER DEMANDS ASSOCIATED WITH ANCHORAGE FORCES CORRESPONDING TO ACI 318-14 SECTION 17.2.3.4.3 AND ACI 318-11 SECTION D.3.3.4.3. 6. DESIGNER MAY USE REDUCED MOMENT DUE TO APPLIED WSW LATERAL LOAD. MINIMUM MOMENT SHALL BE THE LESSER OF THE TABULATED MOMENT OR THE AMPLIFIED _RFD DESIGN MOMENT FOR SEISMIC: (ASD DESIGN DEMAND SHEAR/0.7) x Oo x WSW WALL HEIGHT FOR GRADE BEAM DESIGN. 7. MINIMUM GRADE BEAM DESIGN MOMENT FOR WIND AND SEISMIC IN SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C: (ASD DESIGN DEMAND SHEARIO.6) x WSW WALL HEIGHT. 8. CLOSED TIE MAY BE SINGLE PIECE HOOP OR TWO PIECE ASSEMBLY WITH A U-STIRRUP WITH STANDARD 135 DEGREE HOOKS AND A TOP CROSS TIE CAP. SEE DETAIL 6/WSW1.1. 9. SEE DETAILS FOR GRADE BEAM ANCHOR REINFORCEMENT PLACEMENT, INSTALLATION AND SPACING REQUIREMENTS. CLOSED TIE ANCHOR REINFORCEMENT QUANTITY IS PER WALL FORTHE 12" AND 18" WALL MODELS, AND PER ANCHOR FOR THE 24" MODEL. WSW -AB ANCHOR GRADE BEAM REINFORCEMENT AND DESIGN MOMENTS 5/WSW1.1 35 Installation Details Strong -Tie RIM JOIST, BEAM, OR BLOCKING IF APPLICABLE 6 OR 7 ALTERNATE Zj WSW2 WSW2 TOP PLATES SHEAR V I I �fln W ANSFSW-TOER PLATE 7/8" MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN %", SEE 10/WSW2 FOR SEE 9/WSW2. ALLOWABLE EDGE f FACE DRILL ZO ESAND REGISTERED DESIGN PROFESSIONAL STRONG -WALL° IS PERMITTED TO MODIFY DETAILS _-----WOOD SHEARWALL FOR SPECIFIC CONDITIONS. 1►T&WWAl:[3611060TIONI 4 OR 5 WSW2 WSW2 HEX NUT AND STRUCTURAL WASHER a ' Li Li -� u a u WSW DESIGNED TO PROVIDE Y8" GAP BETWEEN LSL AT BASE OF WSW AND CONCRETE. ENSURE CONCRETE IS LEVEL AND SMOOTH BENEATH PANEL. GRIND OR FILL AS NECESSARY. SINGLE -STORY STRONG -WALL° WOOD SHEARWALL ON CONCRETE 2/WSW2 36 0 Z Z a 0 0 F7 0 cc 0 a 2 0 O 3 3 J U Installation Details 6 OR 7 ALTERNATE WSW2 WSW2 GARAGE HEADER ROUGH OPENING HEIGHT MODEL NO. H CURB ROUGH OPENING HEIGHT WSW12x7 5Y2" 6'-11Yz" WSW18x7 6" 7'1" WSW24x7 WSW12x7.5 WSW 18x7.5 0" TAYz" WSW24x7.5 WSW12x8 5Y" 8'-2" WSW18x8 6" 8'-3Yy' WSW24x8 1. IF REQUIRED ROUGH OPENING HEIGHT EXCEEDS TABLE VALUE, SPECIFY NEXT TALLER PANEL AND TRIM AS NECESSARY. THE STRONG -WALL' WOOD SHEARWALL MAY BE TRIMMED TO A MINIMUM HEIGHT OF 74Y". 2. FURRING DOWN GARAGE HEADER MAY BE REQUIRED FOR CORRECT ROUGH OPENING HEIGHT. 3Ye" MIN. WIDTH BY 9 Y4" MIN. DEPTH HEADER BY OTHERS. FOR WSW AND HEADER FURRING REQUIREMENTS, WHEN APPLICABLE, SEE DETAILS 4/WSW4 AND 5/WSW4. WOOD SHEARWALL II II II II . U U 2= d. d q wsw2 v ° a d° a d GARAGE WALL OPTION 1 OPENING POST AND CONNECTION DETAILS BY OTHERS FOR GARAGE WALL OPTION 2, REGISTERED DESIGN PROFESSIONAL SHALL DESIGN AND DETAIL FOR 1. SHEAR TRANSFER 2. OUT -OF -PLANE LOADING EFFECT 3. INCREASED OVERTURNING AND DRIFT DUE TO ADDITIONAL HEIGHT DESIGN AND DETAILS BY OTHERS Strong -Tie ALTERNATE WHEN WSW -PS STRAPS OMITTED, ALLOWABLE SHEAR VALUES FOR STANDARD PANEL APPLY. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. WOOD SHEARWALL 4 wswz H CURB II� II u d II u J v a d v a d GARAGE WALL OPTION 2 ALTERNATE WSW GARAGE FRONT OPTIONS 3/VVSW2 37 Installation Details Strong -Tie STRONG -WALL® WOOD SHEARWALL REGISTERED DESIGN PROFESSIONAL ° IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. 0 o PLACE STRONG -WALL® WOOD SHEARWALL OVER ... . THE ANCHOR BOLTS AND SECURE WITH WASHER .. .. HEX NUT AND AND HEX NUTS (PROVIDED). SNUG TIGHT FIT .. STRUCTURAL REQUIRED; DO NOT USE AN IMPACT WRENCH. .. WASHER • USE *16" WRENCH FOR %" NUT • USE %" WRENCH FOR 1" NUT 11 1 p q2p d I I I I I I I I I I p I I I Lj _ p Ld I SEE SHEETS WSW1 AND WSW1.1 FOR ANCHORAGE SOLUTIONS Lj Lj �p STANDARD INSTALLATION BASE CONNECTION 4/WSW2 FRAMING BY OTHERS (NOT SHOWN FOR CLARITY) PLACE STRONG -WALL® WOOD SHEARWALL OVER THE ANCHOR BOLTS AND SECURE WITH WASHER AND HEX NUTS (PROVIDED). SNUG TIGHT FIT REQUIRED; DO NOT USE AN IMPACT WRENCH. • USE 1'&" WRENCH FOR %" NUT • USE %" WRENCH FOR 1"NUT FRAMING BY OTHERS (TYPICAL) I I I I I I SILL PLATE i 4 ANCHORAGE u BY OTHERS i d d I I a REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. -STRONG-WALL® STRONG -WALL® WOOD SHEARWALL WOOD SHEARWALL NAILING - BY OTHERS STRONG -WALL® WOOD SHEARWALL HEIGHT TO INCLUDE THE DEPTH OF THE FLOOR SYSTEM AND SHALL BE INSTALLED DIRECTLY ON THE FOUNDATION. SPECIFY PANEL HEIGHT FROM TOP OF FOUNDATION TO UNDERSIDE OF TOP PLATES OR BEAM. BY OTHERS JOIST HANGER (IF REQUIRED) SEE SHEETS WSW1 AND WSW1.1 FOR ANCHORAGE SOLUTIONS SECTION WOOD FLOOR SYSTEM BASE CONNECTION 5/WSW2 38 Installation Details Strong -Tie REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. ALIGN WSW -TOW NOTCHES WITH BOTTOM OF TOP PLATES TOP PLATES , �I I� MAXIMUM WOOD e • SHIM. FOR SHIMS • • • • ATTACH WSW -TOW PLATES GREATER THAN 7/", (PROVIDED) TO FRAMING AND SEE 9ANSW2. WSW PANEL BOTH SIDES • • • • USING 10d x 2Yz" NAILS MIN. FOR 5Ya"-5Yz" FRAMING, 3" MIN. FOR ALTERNATE CONNECTION ATTACH WOOD FURRING • • • SEE 7/WSW2. BLOCK BETWEEN WSW 2" MIN. STRONG -WALL® PANEL AND WSW -TOW WITH WOOD FURRING BLOCK WOOD SHEARWALL SIDSY4" x 3Y2" SCREWS (MIN.) MIN. (REQUIRED FOR 5Ya"-5Yz" OR 16d COMMON NAILS FRAMING MEMBERS) FASTENERS FOR WSW12L10 FOR WSW18 AND SDSYa" X 3Y2, 14 FOR WSW24). MINIMUM 3 MIN' SECTION SECTION BLOCK SIZE IS V/4" x 117/a" x 4x FRAMING 6x FRAMING WSW PANEL WIDTH. STANDARD TOP CONNECTION 6/WSW2 WSW -TOW ALTERNATE CONNECTION KIT MODEL NO. FASTENER QUANTITY SD#10x 1Y2" SIDS J/4"x6" WSW-TOW12KT 20 2 WSW-TOW18KT 28 4 WSW-TOW24KT 40 8 REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. INSTALL SIDS Ya" x 6" SCREWS AT AN ANGLE THAT PREVENTS ALIGN WSW -TOW NOTCHES THEM FROM EXITING SIDE OF WITH BOTTOM OF TOP PLATEStATTACH FRAMING; APPROX. 30 DEGREES (TYP.) TOP PLATES SD #10 x 1Yz" INSTALLfl WSW -TOW ON FACE MAXIMUM WOOD SHIM.EXTERIOR FOR SHIMS GREATERTHAN %", SEE 9/WSW2. 1" DIAMETER WSW -TOW PLATE BY Ya" DEEP VIDED) ON ONE SIDE COUNTERBORE OPTIONAL 1" DIAMETER BYY WITH A COMBINATION Ya" DEEP COUNTERBOREDSY4"x 6" AND SD #10 x STRONG-WALL®ONNECTORSCREWS ER SEPARATELY AS WOOD SHEARWALL -TOW_KT) SECTION SECTION 4x FRAMING 6x FRAMING FURRING NOT REQUIRED FOR ALTERNATE TOP CONNECTION EXCEPT AS REQUIRED FOR FINISH MATERIAL ATTACHMENT ALTERNATE TOP CONNECTION 7/WSW2 39 Installation Details REGISTERED DESIGN PROFESSIONAL END OF PANEL TO IS PERMITTED TO MODIFY DETAILS NEAREST SCREW FOR SPECIFIC CONDITIONS. (SEE TABLE) INSTALL SDS Y4" x 6" SCREWS (ORDER SEPARATELY). INSTALL IN 2 ROWS AS SHOWN AND COUNTERSINK AS REQUIRED. QTY. OF SDSY4" x 6" SCREWS REQ'D. WSW12 4 WSW18 8 WSW24 12 4" MIN. 1--,/ CLEARANCE EDGE DISTANCE FOR SCREWS SLOPE A (IN.) B (IN.) 0:12-4:12 2 3 5:12-8:12 1 1 /2 4 1 /2 9:12-12:12 1 /2 5 1 /2 1. MAINTAIN END DISTANCES TO PREVENT SCREWS FROM PENETRATING THROUGH THE OUTER EDGES. 2. INSTALL SCREWS PERPENDICULAR TO THE TOP PLATE. 3. EDGE DISTANCES ASSUME DOUBLE TOP PLATE. 1" MIN. 1Y4' MIN. FROM EDGE ROW SPACING Yz" MIN. AT EDGE Y2" MIN. SDS TIP TO CHASE - f 1%" O.C. MIN. DOUBLE TOP PLATES SIMPSON STRONG -TIE° A35 FRAMING ANCHORS PLAN VIEW SDS SCREW SPACING /--SIMPSON STRONG -TIE® LTP4 FRAMING ANCHORS STRONG -WALL° WOOD SHEARWALL SECTION VIEW 2X6 OR WIDER FRAMING 1. W-1 IW� INSTALLATION NOTES: 1. ACTUAL CUT LENGTH (L) MUST BE GREATER THAN OR EQUAL TO PANEL WIDTH (W). 2. THIS DETAIL APPLICABLE FOR SLOPES UP TO 12:12. 3. PANELS TALLER THAN 12' MUST BE DESIGNED FOR THE APPLICATION. Strong -Tie (4) SIMPSON STRONG -TIE° LTP4 OR A35 FRAMING ANGLES. MAY BE USED IN COMBINATION (2 PER SIDE). NO HOLES IN HATCHED REGION. RAKE WALL 8/WSW2 40 Installation Details LTP4 SPACING BY OTHERS 4x SHIM BLOCK FOR 8" TO 12" BLOCK DEPTHS: ATTACH SIMPSON STRONG -TIE® CS16 STRAPS AT EDGE OF WSW PANEL (EACH SIDE) USING 10d x 11/2" NAILS SHIM BLOCK HEIGHTS GREATER THAN 8" AND UP TO 10": • 8 NAILS INTO BLOCK • 8 NAILS INTO WSW PANEL SHIM BLOCK HEIGHTS GREATER THAN 10" AND UP TO 12": • 10 NAILS INTO BLOCK • 10 NAILS INTO WSW PANEL 4Y8" TO 12" SHIM BLOCK —FULL-HEIGHT— ADJACENT FRAMING BY OTHERS SEE 6 & 7/WSW2 FOR TOP CONNECTION — STRON G-WALL°— WOOD SHEARWALL Strong -Tie INSTALL SIDS %4' x 6" SCREWS (MIN.) FROM THE TOP SIDE OF THE PLATES PER QTY. AND SPACING REQUIREMENTS DETAILED IN 8/WSW2. 1" TO 4" SHIM BLOCK 4x SHIM BLOCK SEE 6 & 7/WSW2 FOR TOP CONNECTION HALO P A R1A/A I I TOP -OF -WALL HEIGHT ADJUSTMENTS 9/WSW2 41 Installation Details EDGE DRILL ZC MIDDLE %3 OF PAP THICKNE HOLES • MAX. THREE HOL IN FACE AND THE IN EDGE. • 3/4"-DIAMETER HOLES, MAX. • 6" O.C.. MIN. NO EDGE HO ALLOWED IN LOV 26" OF PA NO HOLES ALLOWED IN TOP 8" OF PANEL FACE DRILL ZONE MAINTAIN 1%2" MIN. EDGE DISTANCE FROM CHASE AND OUTSIDE EDGE, TYPICAL. NO FACE HOLES ALLOWED IN LOWER 40" OF PANEL ALLOWABLE SMALL HOLES FACE AND EDGE DRILL ZONES Strong -Tie 0 NO HOLES ALLOWED IN TOP 8" OF PANEL FACE DRILL ZONE CENTER 45/8' OF PANEL FACE AS SHOWN 12" ABOVE EXISTING HOLE, MIN. HOLES • 4%"-DIAMETER HOLES, MAX. 16" • MAX. OF TWO 4%"- DIAMETER HOLES OR ONE 4%4" x 12" HOLE • NO MIN. ON -CENTER SPACING REQUIRED 208" HOLES FOR WSW24X7 PANEL ONLY • MAX. OF ONE 4%" x 6" HOLE • 8" FROM TOP OF PANEL, MIN. ALLOWABLE LARGE HOLES IN ADDITION TO ALLOWABLE SMALL HOLES TRIM ZONES AND ALLOWABLE HOLES 10/WSW2 42 Installation Details Strong -Tie NOTES: 1. 1ST STORY WSW MUST BE THE SAME WIDTH AS THE 2ND STORY WSW. 2. JOIST AND SHEATHING MAY BE ATTACHED TO WSW WITH JOIST HANGER AND LEDGER. LOAD TRANSFER IS THE RESPONSIBILITY OF THE DESIGN PROFESSIONAL OF RECORD. 3. WSW MULTI -STORY KIT (MSK) INCLUDES MSK BEARING BLOCK AND MSK HOLDOWN. LEGEND: • hi = 1ST STORY WSW HEIGHT; TOP OF CONCRETE TO UNDERSIDE OF 1ST STORY TOP PLATES (IN.) • h2 = TOTAL ASSEMBLY HEIGHT; TOP OF CONCRETE TO UNDERSIDE OF 2ND STORY TOP PLATES (IN.) • h3 = h4-2" = 2ND STORY WSW HEIGHT; TOP OF BEARING BLOCK TO BOTTOM OF 2ND STORY TOP PLATES (IN.) • h4 = TOP OF 13T STORY TOP PLATES TO UNDERSIDE OF 2ND STORY TOP PLATES (IN.) REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. TWO-STORY STACKED ELEVATION 2/WSW3 43 Installation Details FOR 2X6 AND WIDER WALL FRAMING; CUT SLOTS IN TOP PLATES TO ALLOW MSK HOLDOWN TO PASS THROUGH. DO NOT NOTCH DOUBLE TOP PLATE. PLAN VIEW 6x FRAMING 2ND STORY STRONG -WALL" WOOD SHEARWALL PLACE 2ND STORY WSW OVER THE MSK HOLDOWN BOLT AND SECURE WITH HEX NUTS (PROVIDED). SNUG TIGHT FIT REQUIRED; DO NOT USE AN IMPACT WRENCH. • USE 1%" WRENCH FOR %" NUT • USE %" WRENCH FOR 1"NUT OR / 7 \ ALTERNATE ATTACH MSK HOLDOWN TO FIRST STORY WSW PANEL USING 10d x 2Yz" NAILS MIN. 1ST STORY STRONG -WALL® WOOD SHEARWALL Strong -Tie REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. MSK BEARING • BLOCK HEX NUT AND STRUCTURAL WASHER SECTION 4x FRAMING: SEE 6 & 7/WSW2 FOR CONNECTION DETAILS SECTION 6x FRAMING: SEE 7/WSW2 FOR CONNECTION DETAILS TWO-STORY STACKED INSTALLATION 3/WSW3 44 Installation Details TOP PLATES MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN %", SEE 9/WSW2. 2x6 MINIMUM FULL -HEIGHT STUD REQUIRED EACH SIDE FOF PANELS OVER 1E FT. TALL. ATTACI- WITH 10d COMMON NAILS AT 16" O.0 REGISTERED DESIGN PROFESSIC IS PERMITTED TO MODIFY DETAIL FOR SPECIFIC CONDITIONS. 4 OR 5 WSW2 WSW2 Strong -Tie 6 ) OR ( 7 ) ALTERNATE WSW2 WSW2 WSW -TOW SHEAR TRANSFER PLATE SEE 10/WSW2 FOR ALLOWABLE EDGE AND FACE DRILL ZONES STRONG -WALL° WOOD SHEARWALL WSW HOLDOWN HEX NUT AND STRUCTURAL WASHER WSW DESIGNED TO PROVIDE %$" GAP BETWEEN LSL AT BASE OF WSW AND CONCRETE. ENSURE CONCRETE IS LEVEL AND SMOOTH BENEATH PANEL. GRIND OR FILL AS NECESSARY. BALLOON FRAMING PANELS OVER 18 FT. TALL 4/WSW3 45 Installation Details 3 TO 5 WSW4 WSW4 WOOD SHEARWALL 39" MIN. WIDTH BY 9Y" MIN. DEPTH HEADER BY OTHERS. FOR WSW AND HEADER FURRING REQUIREMENTS, WHEN APPLICABLE, SEE DETAILS 4NYSW4 AND 51WSW4. SIMPSON STRONG -TIE® LSTA12 STRAP (MIN.) AT BEAM TO POST EACH SIDE 8'-18'-6" CLEAR SPAN OPENING 11 Q b H CLIRB q G . WSW2 d O Q: SIMPSON STRONG -TIE® STHD10 HOLDOWN (MIN.) COLUMN BASE AND POST (DESIGN BY OTHERS) d a' G d G 9 Q Strong -Tie GARAGE HEADER ROUGH OPENING HEIGHT MODEL NO. H CURB ROUGH OPENING HEIGHT WSW12x7 5x" S-11Y" WSW18x7 6" T-0" WSW24x7 WSW12x7.5 WSW18x7.5 0" 7'-%" WSW24x7.5 WSW12x8 1 5y2" WSW18x8 WSW24x8 6" 8'3Yo" 1. IF REQUIRED ROUGH OPENING HEIGHT EXCEEDS TABLE VALUE, SPECIFY NEXTTALLER PANEL AND TRIM AS NECESSARY, THE STRONG-WALO WOOD SHEARWALL MAY BE TRIMMED TO MINIMUM HEIGHT OF 74%". 2. FURRING DOWN GARAGE HEADER MAY BE REQUIRED FOR CORRECT ROUGH OPENING HEIGHT. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. WSW DESIGNED TO PROVIDE Y" GAP BETWEEN LSL AT BASE OF WSW AND CONCRETE. ENSURE CONCRETE IS LEVEL AND SMOOTH BENEATH PANEL. GRIND OR FILL AS NECESSARY. STRONG -WALL" WOOD SHEARWALL SINGLE PORTAL ASSEMBLY F/WSW4 ALTERNATE ALIGN PORTAL STRAP ARROWS WITH BOTTOM " OF HEADER D-1 Y6" MAXIMUM WOOD. " SHIM BETWEEN PANEL AND BEAM e PORTAL STRAPS INCLUDED WITH WSW PANELS UNDER 100". FOR TALLER PANELS, ORDER WSW-PK SEPARATELY. Y2" PORTAL STRAP EDGE DISTANCE FIELD NAIL PORTAL STRAPS TO FRAMING AND WSW PANEL BOTH STRONG -WALL® SIDES (4 TOTAL) USING 10d x2Y2" NAILS MIN. WOOD SHEARWALL LOAD PATH DESIGN AND DETAILS ABOVE HEADER TO BE PROVIDED BY OTHERS. 3Y8" MIN.WIDTH BY 9Y4" MIN.DEPTH HEADER BY OTHERS. FOR WSW AND HEADER FURRING REQUIREMENTS, WHEN APPLICABLE, SEE DETAILS 4NVSW4 AND 5IWSW4. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. PORTAL TOP CONNECTION T3/WSW4 46 Installation Details \_5Y8"-5Y2" WIDE BY 0 0 9Y"MIN.DEPTH • • HEADER BY OTHERS 0 o WOOD FURRING BLOCK (REQUIRED FOR 5y"-5Y2' HEADERS USING STANDARD TOP CONNECTION) 0 o WOOD SHIM WC cranur.-wni i WOOD SHEARWALL REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. Strong -Tie AND STRAP NAILING NOT SHOWN FOR CLARITY `ATTACH WOOD FURRING BLOCK BETWEEN WSW PANEL AND WSW -TOW WITH Y" x 3Y" SIDS SCREWS (MIN.) OR 16d COMMON NAILS AT 3" O.C. STAGGERED (2 ROWS FOR WSW18, 4 ROWS FOR WSW24). MINIMUM BLOCK SIZE IS 1%" x 11%" x DISTANCE BETWEEN SHIMS. / STRONG-WAL0_ STRONG -WALL® WOOD SHEARWALL OD SHEARWALL ATTACH SHIM WITH 2 ROWS OF Ya" x 3Yz"---" SIDS SCREWS (MIN.) OR 16d COMMON NAILS AT 6" O.C. STAGGERED. MINIMUM SHIM SIZE IS 13/" x 5Y4" x HALF OF PANEL HEIGHT. - SECTION SECTION STANDARD ALTERNATE TOP CONNECTION TOP CONNECTION (FURRING BLOCK NOT REQUIRED FOR WSW12) (BLOCK NOT REQUIRED) FURRING FOR 51/8" TO 51/2" HEADER 4/WSW4 3Ya" WIDE BY 9 Y" DEPTH HEADER B OTHERS WOOD FURRING BLOCK (REQUIRED FOR 3Y" HE) WOC STRONG -WALL® WOOD SHEARWALL REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. ATTACH WOOD FURRING BLOCKS BETWEEN PORTAL STRAPS AND HEADER WITH 2 ROWS OF 8-10d COMMON NAILS. MINIMUM SHIM SIZE IS V x 2Y2" x 9y". MIN. Y PORTAL STRAPS AND STRAP NAILING NOT DER) SHOWN FOR CLARITY STRONG -WALL® TRONG-WALL® WOOD SHEARWALL D SHEARWALL SECTION SECTION STANDARD ALTERNATE TOP CONNECTION TOP CONNECTION FURRING FOR 31/8" HEADER 5/WSW4 47 ii C-L-WSW16 02016 SIMPSON STRONG -TIE COMPANY INC. C-L-WSW16 02016 SIMPSON STRONG -TIE COMPANY INC. KA r* N ii C-L-WSW16 02016 SIMPSON STRONG -TIE COMPANY INC. C-L-WSW16 02016 SIMPSON STRONG -TIE COMPANY INC. KA r* N Every day we work hard to earn your business, blending the talents of our people with the quality of our products and services to exceed your expectations. This is our pledge to you. Home Office 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Tel: (925) 560-9000 Fax: (925) 847-1603 Northwest USA 5151 S. Airport Way Stockton, CA 95206 Tel: (209) 234-7775 Fax: (209) 234-3868 Southwest USA 12246 Holly Street Riverside, CA 92509 Tel: (714) 871-8373 Fax: (951) 369-2889 Northeast USA 2600 International Street Columbus, OH 43228 Tel: (614) 876-8060 Fax: (614) 876-0636 Southeast USA 2221 Country Lane McKinney, TX 75069 Tel: (972) 542-0326 Fax: (972) 542-5379 Eastern Canada 5 Kenview Boulevard Brampton, ON L6T 5G5 Tel: (905) 458-5538 Fax: (905) 458-7274 Western Canada 11476 Kingston Street Maple Ridge, B.C. V2X OY5 Tel: (604) 465-0296 Fax: (604) 465-0297 Distribution Centers Chandler, AZ; Eagan, MN; Enfield, CT; High Point, NC; Houston, TX; Jacksonville, FL; Kansas City, KS; Kent, WA; Jessup, MD INTERNATIONAL FACILITIES Please visit our website for address and contact information for our European facilities. (800) 999-5099 www.strongtie.com 0 2016 Simpson Strong -Tie Company Inc. C-L-WSW16 Effective 5/1/2016 Expires 6/30/2018