Loading...
APPROVED STM BLD2021-1102+Storm_Drainage_Report+8.9.2021_10.53.03_AM+2346260RECEIVED RAM Engineering 8-13-21 BLD2021-1102 MPmnran&,, To: City of Edmonds CITY OF EDMONDS Date: August 5, 2021 DEVELOPMENT Engineering Division SERVICES DEPARTMENT COMPLIES WITH APPLICABLE CITY STORMWATER CODE From: Rob Long, PE (V RAM Engineering Subject: Adamant Homes, Inc. - 240th St SW Short Pla Lot 2 O Stormwater Memo RAM Job No. 19-015 This memo provides a summary of the stormwater hard surface allocation for Lot 2 of the Adamant Homes 240th St SW Short Plat (PLN 2019-0052). A site -specific geotechnical evaluation only recommends two possible stormwater BMPs for the site; perforated stub -out connection and BMP T5.13: Post -Construction Soil Quality and Depth. Project impervious/hard surface (roof, driveway, walk/patio areas) will be managed by a shared stormwater detention tank system with the short plat development. The shared detention tank system has been designed as part of the short plat development and thus includes hard surface areas allocated for each individual lot (see Adamant 240t" St SW Short Plat Stormwater Site Plan Report). Lot 2 has an allocation of 3,250 sf of impervious/hard surface, which include roof, driveway, and patio/walkway areas. Below is a stormwater control summary table for Lot 2: Stormwater Control Summary: Project Site Category: Category 2 (part of the Adamant - 240th St SW Short Plat) Discharge Location: City's Municipal Separate Storm Sewer System (MS4) Type of Area Square Footage Storm water Facility Lawn and Landscape 5,138 sf Soil Amendments (BMP T5.13) Roofs 2,368 sf Detention Vault Hard Surfaces 780 sf Detention Vault 25% Retrofit 0 SF None L N co ti 00 Adamant Homes, Inc. - 240th St SW Short Plat- Lot 2 Page 2 of 2 Stormwater Memo RAM lob No. 19-015 240th St SW Short Plat Lot 2 Hard Surface Summary: Roof = 2,368 sf Driveway = 750 sf Patio/Walk = 30 sf Total = 3,148 sf ' - I ro' PRlvAW STOW DRAnJAGE FASE]1Err F r� 112' WATER -WR OCE LINF - r SSW RAL,M WE TO STE18 i'. t -- + + iE 404,01 sr� WIN WAr19 ems ,; Y:1::`; — ;1 ASFAL♦_ ON 55 STUB NWQA'3y'y f46.1.Y . 30[ 4' PLC RQ� TAw A ,! -OCO — 4" PW SW .7WU fq g SF :. 7,�C lA4J A( RAAR1'Ei 1 Mf5 #' PVC FOOhf PRfpRAW AE�+fA-50 7") 029V) � � ' � COvrREq- a4RA W CL FP sro.ou $ f C -- ri4'PRfYA1FSEN!"R __ h SE4tTL1EEASE'✓wErer 750gf 4� -I III ---- A4Y U7RfAE3 --- 236asf dYS�1iLEI13'X 3' �JP1N�L :.. '. .} RIXK FOR WALL LWAfN 14'PItvYrl TS r f ;. i:.,..'. I Ca%AFCTAaV f3'"W DFPEMNS 7W EASE,ufxr 111 RAM Engineering 19109 3611 Avenue W, Suite 100 Lynnwood WA 98036 (425) 678-6960 RAMengineeringinc.com