Loading...
BLD2022-1543_PLANS_11.9.2022_1.28.42_PM_3211885GENERAL NOTES 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.81 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.311 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS EQUIPMENT: AC System Size: 5.22 kW AC / 5.22 kVA DC SYSTEM SIZE: 7.20 kW DC (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverters RACKING: NANOMOUNT - 48" O.C. APPLICABLE GOVERNING CODES 2020 NEC 2018 IRC 2018 IMC 2018 IFGC SITE SPECIFICATIONS OCCUPANCY: R-3 ZONING: RESIDENTIAL Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT SHEET INDEX: PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 ELECTRICAL CALCS PV07 LABELS PV08 PLACARD PV09 SITE PHOTOS DRAWN BY: D.SANCHEZ DATE: 11/2/2022 COVER PAGE - PV01 DALEY ST CLOSE UP OF HOUSE nL-69'-4" EQUIPMENT LEGEND: UTILITY METER ac AC VISABLE,DISCLOCKABLE, LABELED ENV INVERTER NNECT sub SUB PANEL SD SERVICE DISCONNECT PV MODULES METER SOCKET ARRAY DETAILS: MOUNTING PLANE: AZIMUTH: TILT: MP1 1800 20° MP2 1800 200 MP2 MP1 VISIBLE, LOCKABLE, FIRE ACCESS PATHWAY (T TYP) LABELED AC DISCONNE MSP MAIN SERVICE PANEL Pv (FOR UTILITY PV METER) � COMBINER BOX Lc LOAD CENTER BAIT BATTERY(IES) JB JUNCTION BOX PROPERTY LINE LOCATED WITHIN 10' OF UTILITY METER agiffo* 5 L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ CT DATE: 11/2/2022 SITE PLAN - PV02 57'-1 " ELEVATION r T TYP T TYP EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER: SUNMODO ROOF TYPE: COMP SHINGLE PV MODULE COUNT: 18 RAIL PART NUMBER: SMR ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT * 21.69 ft2 = 390.42 ATTACHMENTS NANOMOUNT RAFTER/TOP CHORD SIZE: 2" X 4" ROOF AREA: 2893.61 ftz ATTACHMENT CITY: 36 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 13% SPLICE CITY: 4 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT * 52 Ibs = 936 Ibs MIDCLAMP CITY: 28 POINT LOAD: ARRAY LBS/ATTACHMENTS = 26.00 ENDCLAMP CITY: 16 DISTRIBUTED LOAD: (Ibs/ft2) (ARRAY) WEIGHT/AREA = 2.4 Ibs/ft2 Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 11/2/2022 ROOF ATTACHMENTS - PV03 �� END CLAMP DETAILS Material: Aluminum Finish: Black Powder Coating I r - aan i I i�u Material: EPDM + Stainless Steel SHARED RAIL SHARED RAIL BONDING END CLAMP MID CLAMP PV MODULE PV MODULE RAIL RAIL �� MID CLAMP DETAILS R4 nm q r— nw sv Material: Stainless Steel Finish: Clear DETAIL, MOUNTING AND FLASHING 1'-8" MAX 48" MAX SPAN 6" MAX RAIL NANO MOUNT 2'-8" MIN - 3'-10" MAX (E) RAFTER/TOP CHORD FRONT VIEW 10" MIN - 7 1'-4" MAX / SIDE VIEW PV MODULE RAIL 2'-8" MIN - 3'-10" MAX k? (E) RAFTER/TOP CHORDS 10" MIN - 1'-4" MAX EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER: SUNMODO ROOF TYPE: COMP SHINGLE PV MODULE COUNT: 18 RAIL PART NUMBER: SMR ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT * 21.69 ftZ = 390.42 ATTACHMENTS NANOMOUNT RAFTER/TOP CHORD SIZE: 2" X 4" ROOF AREA: 2893.61 ft2 ATTACHMENT CITY: 36 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 13% SPLICE CITY: 4 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT * 52 Ibs = 936 Ibs MIDCLAMP CITY: 28 POINT LOAD: ARRAY LBS/ATTACHMENTS = 26.00 ENDCLAMP QTY: 16 DISTRIBUTED LOAD: (Ibs/ftz) (ARRAY) WEIGHT/AREA = 2.4 Ibs/ftz Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 11/2/2022 MOUNTING DETAIL - PV04 HANWHA Q.PEAK DUO L-G5.2 400 Specs POWER MAX (PMAX): 40OW OPEN CIRCUIT VOLTAGE (VOC): 49V MAX POWER -POINT CURRENT (IMP): 9.75A MAX POWER -POINT VOLTAGE (VMP): 41.04V SHORT CIRCUIT CURRENT (ISC): 10.24A SERIES FUSE RATING: 20A STRING (1): 20.OA ENPHASE : IQ8PLUS-72-2-US (240V) Specs MAX INPUT VOLTAGE: 480 V MAX INPUT CURRENT: 20 A NOMINAL DC INPUT VOLTAGE: 400 V MAXIMUM OUTPUT POWER: 290 W NOM. OUTPUT VOLTAGE: 240 V MAX OUTPUT CURRENT: 1.21 A 1-Phase, 60 HZ, UL 1741 Listed 690.12 RAPID SHUTDOWN COMPLIANT Equipment Schedule TYPE: CITY: DESCRIPTION: RATING: MODULES: (18) HANWHA Q.PEAK DUO L-G5.2 400 400 W INVERTERS: (18) ENPHASE IQ8PLUS-72-2-US(240V) 290 W AC DISCONNECTS: (1) PV AC Disconnect, 240V, 2-Pole With 30A Fuses 60 A COMBINER BOX: (1) ENPHASE COMBINER 4 125 A 9 MODULES = I "I = I - L— — — — — —— — — — —— ----�— -- ----� J-BOX I STRING (2): 20.OA 1 2 9 MODULES I I I I I I I - ------ ----i -- ---- ----- -- — J-BOX 1-BOX (N)240V/125A PV ENPHASE PV LOAD CENTER, AC COMBINER WITH INTEGRATED MONITORING, NEMA 3R RATED ENVOY -IQ MONITOR 2P-10A T T 2P-20A I 2P-20A I 4 - - -CGND} - - Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE (2) 10 AWG (90°C) Q-CABLE , COPPER (L1, L2) 1 (1) 6AWG (90-C) THWN-2COPPER -(GROUND) N/A - FREE AIR 2 (2) 10 AWG (90-C) THHN/THWN-2, COPPER - (LI, L2) 3/4" EMT (1) 10AWG (90-C) THWN-2COPPER -(GROUND) 3 (4) 10AWG(90°C) THHN/THWN-2,-(L1,L2) 3/q EMT (1) 10AWG (90-C) THWN-2COPPER -(GROUND) (3) 10 AWG (90°C) THHN/THWN-2, COPPER - (LI, L2, NEUTRAL) 4 (1) 10AWG (90-C) THWN-2COPPER -(GROUND) 3/4" EMT (3) 6 AWG (75-C) THHN/THWN-2, COPPER - (LI, L2, NEUTRAL) 5 (1) 6AWG (75-C) THWN-2COPPER -(GROUND) 3/4" RMC/IMC PV AC DISCONNECT 60A VISIBLE, LOCKABLE, UTILITY PV PRODUCTION LABELED, OPEN METER BASE 240V, 2-POLE LINE SIDE WITH 30A FUSES CONNECTION AS A LINE/SUPPLY SIDE CONNECTION - NEC 705.12(A) (E) 100A MAIN SERVICE PANEL (E) 10OA-2 (E) LOADS (E) LOADS LOAD SIDE N 5 r � L _ J (E) GROUNDING ELECTRODE LINE SIDE TAP USING INSULATION PEIRCING 705.12(A) I I I 120/240 VAC TO UTILITY GRID (E) UTILITY METER VISIBLE, LOCKABLE LABELED AC DISCONN LOCATED WITHIN 1 OF UTILITY METE ffV9iff9* 5 L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ ECT DATE: 01 11/2/2022 R LINE DIAGRAM - PV05 STRING CALCULATIONS ENPHASE : IQ8PLUS-72-2-US (240V) STRING #1 STRING #2 MAX AC CURRENT 14A 14A MICRO INVERTER(S) IN SERIES: 9 9 NOMINAL VOLTAGE / RANGE 211V - 264V 211V - 264V MAX AC OUTPUT POWER: 261OW 261OW ARRAY DC POWER: 720OW TOTAL MAX AC CURRENT: 21.75A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES 4-6 .80 7-9 .70 10-20 .50 SYSTEM OCPD CALCULATIONS INVERTER MODEL(S): ENPHASE IQ8PLUS-72-2-US (240V) # OF INVERTER(S): 18 MAX OUTPUT CURRENT: 1.21A (# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING (18 X 1.21A X 1.25) = 27.19A <= 30A, OK PV LOAD CALCULATIONS: SUPPLY SIDE TIE-IN FEEDER WIRE RATING: 100A ALLOWABLE SOLAR CALCULATION (FEEDER RATING - 1.25) 80.000OA (FEEDER WIRES ALLOWABLE SOLAR) 80.000OA (AVAILABLE FOR PV) Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENTTEMP TEMP. DERATE # OF CONDUCTORS DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 (2) 10 AWG Q-CABLE , COPPER (L1, L2) N/A - FREE AIR 40A 900C 260C 1.0 N/A - FREE AIR 38.4A N/A - FREE AIR (1) 6 AWG THWN-2 COPPER- (GROUND) 2 (2) 10 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" EMT 40A 90°C 26°C 1.0 1.0 40.OA 11.45% (1) 10 AWG THWN-2 COPPER - (GROUND) 3 (4) 10 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" EMT 40A 90°C 26°C 1.0 0.8 32.OA 19.09% (1) 10 AWG THWN-2 COPPER - (GROUND) 4 (3) 10 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" EMT 40A 90°C 26°C 1.0 1.0 40.OA 15.3% (1) 10 AWG THWN-2 COPPER - (GROUND) 5 (3) 6 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" RMC/IMC 65A 75°C 26°C 1.0 1.0 65.OA 35.5% (1) 6 AWG THWN-2 COPPER - (GROUND) GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH S L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) LSNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 11/2/2022 ELECTRICAL CALCS - PV06 ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION I A\ WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. Zt WARNING INVERTER OUTPUT CONNECTION DO NOT RECOLCATE THIS OVERCURRENT DEVICE I J\ WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABELING NOTES: LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABEL 2 PLACED ADJACENTTO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(b)] LABEL 3 PLACED ADJACENTTO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(C)] LABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO MAIN SERVICE PANEL INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] LABELS AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.11 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SOLAR ELECTRIC SWICH TO THE "OFF PV PANELS POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR• 1 WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF' POSITION TO SHUT DOWN I —' CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT LABEL 6 AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. Ol O2 OO4 LABELING DIAGRAM: EXISTING SUB PANEL PV COMBINER (IF WHERE POINT OF SUBPANEL- INTERCONNECTION IF USED TO COMBINE INVERTER (S) IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS °❑° 0 0 0 0 O 77DCI (ONLY IF PV INTERCONNECTION (ONLY IF PV INTERCONNECTION ❑ O O CONSISTS OF LOAD CONSISTS OF LOAD SIDE BREAKER) SIDE BREAKER) INTEGRATED DC DISCONNECT 6 JUNCTION BOX OR COMBINER BOX 06 *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. '\ 44, _ * ■■ ■ ■T�!� �� + r Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 11/2/2022 LABELS - PV07 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: COMBINER BOX AC DISCONNECT PV METER UTILITY METER MAIN DISTRIBUTION UTILITY DISCONNECT PV ARRAY 1044 DALEY ST, EDMONDS, WA 98020 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.101) Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION 1ULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 11/2/2022 PLACARD - PV08 SITE PHOTOS: Weslmmouse c = # � R► 22 89 �22� e 43 34� 43 T 43 132 I' K I L O W Ai T T H® U R S 2A — in 2 FLA2" a SINGLE-STATOP VIATTMOUR METER' TYPE M s.5570C24GJ6 FORM 00 OL 240, V 3W 60 HZ TA 30 h 7.2 W SNOHOL11SH 0 577 COUNTY 76 361 57 Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION JULIA CONSTANCE MAUGHAN 1044 DALEY ST EDMONDS, WA 98020 AC System Size: 5.22 kW AC / 5.22 kVA DC System Size: 7.20 kW DC Lat, 47.8135522 Long,-122.3625535 (18) HANWHA Q.PEAK DUO L-G5.2 400 PV Modules (18) ENPHASE IQ8PLUS-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT DRAWN BY: D.SANCHEZ DATE: 11/2/2022 SITE PHOTOS - PV09 powered by �DUO THE IDEAL SOLUTION FOR: Rooftop arrays on MY Ground -mounted commercial/industrial solar power plants buildings Engineered in Germany LOW ELECTRICITY GENERATION COSTS Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 20.1%. INNOVATIVE ALL-WEATHER TECHNOLOGY (291� Optimal yields, whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID U ` Technology', Hot -Spot Protect and Traceable Quality Tra.QM. EXTREME WEATHER RATING High-tech aluminum alloy frame, tested to the extreme in Australia for Australian Conditions at James Cook University Cyclone Testing Station. A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. ( �3� STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. ' APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168 h) See data sheet on rear for further information. GICELLS MECHANICAL SPECIFICATION Format 2015mm x 1000mm x 35mm (including frame) Weight 23.5kg Front Cover 3.2 mm thermally pre -stressed glass with anti -reflection technology T Back Cover Compositefilm Frame Anodised aluminium Cell 6 x 24 monocrystalline G.ANTUM solar half cells Junction box 70-85mm x 50-70mm x 13-21mm Protection class IP67, with bypass diodes Cable 4mm2Solar cable; (+)>_1350mm,(-)>_1350mm Connector Staubli MC4-Evo2; IP67 z6aIIAJ_ -I°.°min Ma-IOI,mm ELECTRICAL CHARACTERISTICS POWER CLASS 380 385 390 395 400. MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5W /-0 W) Power at MPP' P.. IwI 380 385 390 395 400 Short Circuit Current' Isc [A] 10.05 10.10 10.14 10.19 10.24 E Open Circuit Voltage' Voc IV] 4795 48.21 48.48 48.74 49.00 Current at MPP INpp [A] 9.57 9.61 9.66 9.70 9.75 Voltage at MPP VMpp [V] 39.71 40.05 40.38 40.71 41.04 Efficiency' 9 [%] >_18.9 >_19.1 >_19.4 >_19.6 >_19.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT' Power at MPP PMPP [W] 284.4 288.2 291.9 295.6 299.4 E Short Circuit Current Isc [A] 8.10 8.14 8.17 8.21 8.25 E Open Circuit Voltage Voc IV] 45.21 45.46 45.71 45.96 46.21 'c Current at MPP I-P [A] 7.53 7.57 760 7.64 767 Voltage at MPP VMpp IV] 37.77 38.08 38.40 38.71 39.02 'Measurement tolerances PMpp±3%; Isc; Vac +-5%at STC: 1000 W/m', 25±2°C, AM 1.5G according to IEC 60904-3 • z800 W/m�, NMOT, spectrum AM 1.5G Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98%of nomina power dur- ?<. 1O-r-----r I n---- &3 ° ing first year. Thereafter max. 0.54% o I I - degradation per year. At least 93.1% u, w8 of nominal power up to 10 years. At a F `z least 85%of nominal power up to W < g 25 years. ' A w __r_____r____y_____y_____J rc °z u c All data within measurement toter- � ances. Full warranties in accordance w a ° zao with the warranty terms of the 400 6M 800 OW o „ Q CELLS sales organisation of your IRRADIANCE M1mil respective country. e e�m'm o 416p�p°o < YEARS Typical module performance under low irradiance conditions in comparison to STC conditions (25°C, 1000 W/m0. TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vcc R [%/K] -0.27 Temperature Coefficient of PMpp y [%/K] -0.36 Normal Module Operating Temperature NMOT I°C] 43±3 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vs [VI 1500 (IEC)/1500 (UL) Safety Class II Maximum Reverse Current IR [A] 20 Fire Rating C/TYPE 1 Max. Design Load, Push/Pull [Pa] 3600/1600 Permitted Module Temperature-40°C-+85°C Max. Test Load, Push/ Pull [Pa] 5400/2400 on Continuous Duty QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION IEC 61215:2016; IEC 61730:2016, Application Class II; Number of Modules per Pallet 29 This data sheet complies with DIN EN 50380. Number of Pallets per Trailer (24t) 24 C / Se® Number of Pallets per 40' HC-Container (26 t) 22 pVE (`� o a„m us Pallet Dimensions (L x W x H) 2080 x 1150 x 1190 mm Pallet Weight 742 kg Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Made in Korea Hanwha O CELLS Australia Pty Ltd Suite 1, Level 1,15 Blue Street, Sydney, NSW 2060, Australia I TEL+61(0)2 9016 30331 FAX +61(0)2 9016 30321 EMAIL q-cells-australia@q-cells.com I WEB www.q-cells.com/au Engineered in Germany OCIELLS ENPHASE IQ8 Series Microinverters IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Enphase 1 25 year limited warranty Part of the Enphase Energy System. IQ8 Series IQ8 Series Microinverters redefine reliability Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Enphase IQ Gateway, and the Enphase App monitoring hours of power -on testing, enabling an industry - and analysis software. leading limited warranty of up to 25 years. Connect PV modules quickly and easily to I08 Series IQ8 Series Microinverters are UL Listed as Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations. when installed according to manufacturer's instructions. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8S E-DS-0001-01-EN-US-2022-03-17 Easy to install Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down* More than one million cumulative hours of testing Class II double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support** Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21(UL 1741-SA) requirements • Only when installed with IQ System Controller 2, meets UL 1741. IQ8H-208V operates only in grid -tied mode. IQ8 Series Microinverters supports split phase, 240V. IQ8H-208 supports split phase. 208V only. Commonly used module pairingsz w 235 - 350 235 - 440 260 - 460 295 - 500 320 - 540+ 295 - 500, Module compatibility 60-cell/120 half -cell 60-cell/120 half -cell, 66-cell/132 half -cell and 72-cell/144 half -cell MPPT voltage range V 27 - 37 29 - 45 33 - 45 36 - 45 38 - 45 38 - 45 Operating range V 25 - 48 25 - 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current' [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration OUTPUT DATA 1x1 Ungrounded array: No additional DC side protection required; AC side protection requires max 20A per branch circuit 1: 1:' 1: 1: 1: 1IQBH-208-72-21 Peak output power VA ,I 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range' V 240 / 211- 264 208 / 183 - 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50 - 68 AC short circuit fault current over 2 4.4 3 cycles Arms Max units per 20 A (L-L) branch circuit' 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85 leading - 0.85 lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption MECHANICAL DATA raw 60 Ambient temperature range -40°C to +60*C (-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") Weight 1.08 kg (2.381bs) Cooling Natural convection - no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA)• UL 62109-1• UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. (1) The I081-1-208 variant will be operating in grid -tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-17 Enphase 10 Combiner 4/4C Enphase IQ Combiner 414C AQ_1rv111f I—L`�i 0-4 —�Q'—A M 1-240-4 The Enphase IQ Combiner 414C with Enphase IQ Gateway and integrated LTE-Ml cell modern (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ rnicroinverters and storage installations by providing aconsistent, pyre -wired soluticin for residential aaplicaticris. It offers up to four 2-pole input circults and Eaton BIR series hushar assembly. Smart • Includes IQ Gate -Hay or commun-cation and Control • Includen Enphase NI InbileCon nest. ne lular modem CELL MOD EM-M1-06-SP-05)• indudle€i onlyr with IQ CDmbiner 4C • includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Flexible networking supports hrdi-Fi. Ethernet, or Cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption morkaring Silmpl e • Centered mount`ng bra: kets support single stud mount-ng • Supports bottom. back and side oanduit entry Up to Four 2-pole branch circuits for 240. VAC plulg-in breakers (not includ4 00A, tctal PV or storage branch circuits I Reliable Durable NRTL-certified NEI IA type 3R encilosure Five-year limited warranty • Two years labor reimbursement program coverage included 'or both the IQ Combiner SKLI's MODEL NUMBER IQ Combiner 4 (X-1Q-AU1-20-4) IQ Cambiner4wIth Enphase IQ GairmW pdnud abmlt bowd kw lmugrztcd m-mnue trade; Pity' pnxLctmn meUring (ANSI C12.20 +".5%) and ccnsumpdon mamitariV (+rr- 2.5). lncL ho a siver sal m shield W match the 1,0 Bsattair. sxsuern and IQSystiemCorruolkr 2 and to deflect heat. IQ Combiner 4C (Y-I0-AM11-240-4C) IQCembIner 4C wlth Erithase IQ^3altwa prlrned clrcuitboard kar Integrated revenue riadePr+prDd _1Ldon niter ng (ANSIC1220 }1-0.5%) and consumption monitoring {+F-2.S95). Includes Enphase MobileCameci re 'ular modem (CELLMODEI l-W1-06-&P-65), a plug -and -play industrial -grade Dell modem 9oa systems up is 60 microinverters. (Available in the US, Canada, Mexico, PoJertD Rico, and the LFS''Virgn Islands, where there is adequate calkilse service in the Installation area.) Includes a silYer sokrshiekf to match the iD Banery and IQ system Conrialler and to deflecl heat. ACCESSORIES AND REPLACEMENT PARTS (not included. order separately;l EnsembleCDmmunicatlonsKit -includes COMMS-IUT-01and CIFUNI DEk1-1'l-O&SP-05with5-yearSprintdataplanfar COMMS-CELLMOD;EM-Mi-06 Ensemble sites CELLNIODE#dA41-06-SP-05 4G based LTE-kit cellular modem with 5yrcar Sprint data plan CEL.LMODEii l-D6-AT 05 4G based LTE-kit cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210, BR215, BR22D, SR230, QR240, BR250, and BR260 circuit breakers. BRK-IDA-2-24D+V Clrcue brLaker, 2 pok,10A, Eaton 8R210 BRK-15A,-2-240V Clrcuii brLaker, 2 pok,1SA. Eaton 8 R21 5 BRK-20A-215-24DV Clrcuit brLaker, 2 pok, 20A,Eaton BR220 BRK-15A-213-240V-E Clrc u e breaker, 2 pole. 15A., Eason B R2158 with hold down kit support BRK-20A-7P-240V-8 CI¢ u it breaker, 2 pole, 20A.Eaton GR2:208 with hold down kitsuppart EPL a-01 Power line carrier (communication bridge pair), quanllty - one psi' XA-a4LARSHIELD-ES Replacement solar shield for IQ Combiner 44C %.4-PLUG-124-8 Accessory receptacle for Pvweir Una Carrier In IQ Combiner 414C (required for EPLC-D1) XA-E4V-PC8A.-3 Replacement IQ Gateway printed circuit board (P''B) Far C-amb!rier 414C X-IQ- NA-RD-125A lipid down kit for Eaton r%di breaker with screws. ELECTRICAL SPECIFICATIONS Rating System rallage Eaton BR series bulbar ratng Max. ccmiruaus carer, rating Max- continuous current ra" (input from PVjatarage) Maer. fusercircultrating (Ditpui) Branch c rcuAs (saint andfar 5wrage) Mm. [vial Imanch circuit breaker rating (Input) PrDductlon meurirg CT Garnil duty 12Df240 VACS dD 1♦z 125 As 65 A 64 A 4 D A, up to four 2-pole Entan DR series Dlstrllwtsd Generaticn (DG) breakers only (not Included) BOA al cilstrlbuied generation r' g5A with It; "gateway breaker included 200 A solid care pre -Installed end wired to IQ Gateway Consumption monitoring CT (CT-20D-SPLIT) A par of 200 A spilt core current bansFcemem MECHANICAL DATA Dlmenslons (WaWxD) 37.5x 49.5 x 16.e enu(14:75• c i9.5' x 6.63'j. I3alght is 21.06';53.5 cmi widi mounting brackets. We rght 7.5kg (16.5 bs) Amblent temperature range -409 C So+490 C (40Q to 115Q F� Cooling Natural cDnvectian, plus heat shle Id Enclosureern-iranmental rating Duldoor, NRTL-certified, NE"type 2R, paiycarbonate construction Wire sizes • 20 A to 50 A breaker Inputs: 14 to 4 AWG capper conductors • 60A breaker branch input:410 110 AWG copper conductorz Un n lug cambned output: 10 to 2f0 AWG copper conductors Neutral and ground: 141a 110 capper canckimrs A -.Ways follow IDcal code requiementsfor conductor sizing.. AIIJUAW To 2000 meters (6.560 feet) INTERNET (CONNECTION OPTIONS Integrated WI-FI 602-111SAWn Cellular CELLMDDEM-MI-06-SP-05,CELL.MODEk4-MI-06-AT-05(4GbasedLTE-41 cellular modern). Note*natanEm ase Mehlk (need cellular modem is required for all Ensemble Installations. Ethernet Opllonal, 902.0, CatSE (or Cat 6) LITP Ethernet cable (mot included) COMPLIANCE C impliance, IQ Combiner u L 1741, C kNl CSA C22.2 No. 107.11. 47 CFR; Part 15w Ciaas 4, IC LG 003 Production mewrinq: ANSI C12.2D accuracy class h 5 (PV producllan) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway uL 60601.1/CANCSA22.2 No. 61,310-1 USTE8 To le.ar;� mc.ne about Enphase offerirvg, vrisd eapha e.coni ENIPHASE To learn more ab iLd Enphase offerings, visit enphase.co E N P H E- E- 2021 en:rhase Enery-j. Al righls rt:=-ved. u.nrha:x, the Cn�fuue k,rp. IQ CL-mire- 44C, ant: ulhei rlarrCs a: a I adw r s hs ul Er:d-ar& Energy: Inc. Data suaject le charr4e. '10-21-2021 SUNMOI7 Part Number Description K50058-BK1 NanoMount . NanoMount . USWR Gasket NanoMount Material: Aluminum Finish: Black Powder Coating NanoMount Gasket Material: USWR Gasket with Adhesive D10214-VO04 Dimensions shown are inches (and millimeters) 9 Details are subject to change without notice SUNMO11IF'O Part Number Description K50049-BK1 Lag Bolt Assembly • Hex Lag Bolt M8X1 15, DIN 571, 304S • Sealing Washer .33 ID X .75 X .157 K50055-BK1 Decking Screw Assembly . Self -Tapping Screw, #14 X 3.00 . Sealing Washer .261D X .50X .125 Lag Bolt Assembly 1. Hex Lag Bolt M8X1 15, DIN 571, 304 Material: Stainless Steel Finish: Clear 2 Sealing Washer .331D X.75X.157 r F— — I pssl sous ne of I I I'— — r � Material: EPDM + Stainless Steel Decking Screw Assembly 1. Self Tapping Screw, #14 X 3.00 HLK :-.._._- .................................. on + 89J Material: Stain Finish: Clear 2. Sealing Washer .261D X .50X .125 r _ 0.: I \ MW Oo ss I t I I t1 !J I t• — � i Material: EPDM + Stainless Steel D10214-VO04 pimensions shown are inches (and millimeters) Details are subject to change with xd notice SUNMOD'O Part Number Description A20422-168-BK SMR100 Rail, Black Anodized, 168" A20453-168-BK SMR200 Rail, Black Anodized, 168" A20440-BK1 Rail End Cap, SMR100, Black A20440-BK2 Rail End Cap, SMR200, Black SMR100 Rail Mechanical Properties Section Properties Material: 6005-T5 Aluminum Sx: 0.196 in3 (3.21 cm) Weight: 0.4126 Ibs/ft (0.614 kg/m) Sy: 0.146 in3 (2.39 cm3) Ultimate Tensile Strength: 37.7 ksi (260 MPa) Area (X-section): 0.352 in (2.27 cm') Yield Strength: 34.8 ksi (240 MPa) SMR200 Rail Mechanical Properties Section Properties Material: 6005-T5 Aluminum Sx: 0.321 in3 (5.26 cm3) Weight: 0.645 Ibs/ft (0.960 kg/m) Sy: 0.272 in3 (4.46 cm3) Ultimate Tensile Strength: 37.7 ksi (260 MPa) Area (X-section): 0.551 in2 (3.55 cm2) Yield Strength: 34.8 ksi (240 MPa) D10225-VO04 Dimensions shown are inches (and millimeters) Details are subject to change without notice SUNMOMWO Part Number Description K10421-002 Structural Splice, SMR100 K10462-002 Structural Splice, SMR200 K10433-BK1 L Foot Adaptor, SMR100, Black K10434-BK1 L Foot Adaptor, SMR200, Black SMR100 Bonding Rail Splice s� ,+as of ]91 ,5z5, L O hnn NE%IXtlVE SMR200 Bonding Rail Splice 2 zoo u s1 O L SMR100 L-Foot Adaptor — 1.40 135.SJ SMR200 L-Foot Adaptor `—NEx ' 138 135.0) 1.37 134.e1 0mm HEX DRNE 2.0) 150.71 1 1.37 134 9J Materials: 1. Extrusions 6005-T5 Aluminum 2. Hardware 304 Stainless Steel D10225-VO04 Dimensions shown are inches (and millimeters) —00 15oe1 0 6mm HEX ERNE J Details are subject to change without notice SUNM*00`0 Part Number Description K10417-BK3 Mid Clamp, SMR Pop -On, Black K10418-BK3 End Clamp, SMR Pop -On, Black K10419-BK1 Shared Rail Mid Clamp, SMR Pop -On, Black K10420-BKl Shared Rail End Clamp, SMR Pop -On, Black Pop -On Bonding Mid Clamp 8mm HEX DRIVER REQUIRED Pop -On End Clamp 0.47 112.0] 1 RANGE 30-48mm 8mm HEX DRIVER REQUIRED j�RANGE 7W&nn 1 Shared Rail Bonding Mid Clamp &— HEX DRIVER REQUIRED Shared Rail End Clamp 049 -- I12AI RANGE 0 8mm HEX DRIVER �REWIRED 7 RANGE Materials: 1. Extrusions 6005-T5 Aluminum 2. Hardware 304 Stainless Steel D10225-V004 Dimensions shown are inches (and millimeters) Details are subject to change without notice