APPROVED BLD2022-0240+Plumbing_Plan+2.23.2022_2.29.31_PM+2698715w`
PLUMBING GENERAL ABBREVIATIONS
ABBV
FULL NAME
ABBV
FULL NAME
ABBV
FULL NAME
AAV
AIR ADMITTANCE VALVE
DN
DOWN
NTS
NOT TO SCALE
ABV
ABOVE
DS
DOWNSPOUT
OFD
OVER FLOW DRAIN
AFF
ABOVE FINISHED FLOOR
DWG
DRAWING
POC
POINT OF CONNECTION
AP
ACCESS PANEL
E
EXISTING
PRV
PRESSURE REDUCING VALVE
BEL
BELOW
ELEV
ELEVATION
PVC
POLYVINYL CHLORIDE
BFP
BACKFLOW PREVENTER
ET
EXPANSION TANK
RD
ROOF DRAIN
BOP
BOTTOM OF PIPE
EWH
ELECTRIC WATER HEATER
RPBA
REDUCED PRESSURE BACKFLOW ASSY
BV
BALL VALVE
F
FIRE
TOG
TOP OF GRATE
BWV
BACK WATER VALVE
FCO
FLOOR CLEAN OUT
UG
UNDER GROUND
CB
CATCH BASIN
FD
FLOOR DRAIN
LINO
UNLESS NOTED OTHERWISE
CFF
CAP FOR FUTURE
FU
FIXTURE UNIT
VTR
VENT THRU ROOF
CI
CAST IRON
GI
GREASE INTERCEPTOR
W/
WITH
CL
CENTER LINE
GPM
GALLONS PER MINUTE
WCO
WALL CLEAN OUT
CO
CLEAN OUT
GWH
GAS WATER HEATER
WH
WALL HYDRANT
CPVC
CPVC MATERIAL
HB
HOSE BIBB
WHA
WATER HAMMER ARRESTOR
DCBP
DOUBLE CHECK BACKFLOW PREVENTER
HP
HIGH PRESSURE
WM
WATER METER
DCVA
DOUBLE CHECK VALVE ASSEMBLY
IE
INVERT ELEVATION
YH
YARD HYDRANT
DEMO
DEMOLISH
MH
MANHOLE
DFU
DRAINAGE FIXTURE UNIT
NIC
NOT IN CONTRACT
PLUMBING SYMBOL LEGEND
SYMBOL
DESCRIPTION
ABBV
SYMBOL
DESCRIPTION
ABBV
0
BALANCING VALVE
BALV
GAS COCK
GC
D4
GATE VALVE
GV
VERTICAL EXPANSION TANK
VET
D�4
GLOBE VALVE
GLV
I
TEMPERATURE GAUGE
TG
BALL VALVE - FULL PORTED
BV
Q
THERMOMETER
THERM
`ILl
SILENT CHECK VALVE
CV
Dzl ,
BALL VALVE W/ 3/4" HOSE ADAPTOR
BV W/ HA
®
REDUCED PRESS. BACKFLOW PREVENTER
RPBP
_
p
CONCENTRIC REDUCER
CR
(�
BACKFLOW PREVENTER
BFP
TWO-WAY CONTROL VAVLE
2WAY
=
UNION
UNION
THREE-WAY CONTROL VALVE
3WAY
STRAINER
STRN
POINT OF CONNECTION
P.O.C.
PRESSURE RELIEF VALVE
PTV
PIPE BREAK - PIG TAIL
PRESSURE REDUCING VALVE
PRV
6" cHWS
PIPE - SIZE & ABBREVIATION
T
PRESSURE / TEMPERATURE PORT
P/T
s cHWS
PIPE - SIZE & ABBREVIATION WITH INSULATION
Q
PRESSURE GAUGE
PG
@)
PUMP CIRCULATION
SOLENOID VALVE
SV
g
ROOF DRAIN (RISER)
RD
PIPE - HEAT TRACE
pL�
OVER -FLOW DRAIN (RISER)
OD
HOSE BIB
HB
60" OFFSET FOR SUDS
60' OFST
4
SUB -METER WATER FLOW
MTR
EXPANSION THERMAL
EXP
WATER HAMMER ARRESTOR
WHA
'nTRiT
DOMESTIC PEX MANIFOLD
MFLD
FLEX PIPE
PLUMBING TRAP
TRAP
jig
VENT THROUGH ROOF
VTR
FLTR 1
PLUMBING FIXTURE N.I.C. TAG
m
FLOOR CLEANOUT
WC-1
PLUMBING FIXTURE TAG
O-1
WALL CLEANOUT
WTR-1
PLUMBING EQUIPMENT TAG
00 ®
FLOOR DRAINS
1/2°7�
1/16" PER FOOT PIPE SLOPE
® ®
FLOOR SINKS
11 ��%S�
1/8" PER FOOT PIPE SLOPE
Qo ®O @®
ROOF, OVERFLOW, AND COMBINATION DRAINS
2% SLOPE
1/4" PER FOOT PIPE SLOPE (TYP. UNO)
PLUMBING SYSTEM LEGEND
LINE TYPE & ABBR FULL NAME
LINE TYPE & ABBR FULL NAME
ACID
GAS, NATURAL
ACID VENT
NATURAL GAS HIGH PRESSURE
ACID WASTE
NATURAL GAS LOW PRESSURE
BEVERAGE
NATURAL GAS MEDIUM PRESSURE
BEVERAGE CONDUIT
NATURAL GAS 2PS1
DOMESTIC WATER
NATURAL GAS 5PS1
- - - DOMESTIC COLD WATER
NATURAL GAS VENT
DOMESTIC COLD WATER (UNDERGROUND)
NATURAL GAS CONDUIT
_ _ _ DOMESTIC COLD WATER - HIGH PRESSURE
SANITARY SEWER
- - - DOMESTIC FILTERED WATER
GARAGE DRAIN
- - - - - - DOMESTIC HOT WATER
GREASE WASTE
- - - - - - - DOMESTIC HOT WATER 140
GREASE WASTE (UNDERGROUND)
- - - - - - DOMESTIC HOT WATER 160
INDIRECT WASTE
- - - - - - - - - - - - - DOMESTIC HOT WATER CIRC
- - - - - - - - - - - - - - - LAB VENT
- - - - - - - - - - - - - DOMESTIC HOT WATER CIRC 140
- - - - - - - - - - - - - - - LAB WASTE
- - - - - - - - - - - - - DOMESTIC HOT WATER CIRC 160
PUMPED SANITARY SEWER
- - - - - - - - DOMESTIC HOT WATER - HIGH PRESSURE
PUMPED WASTE
- - - - - - - - - - - - - DOMESTIC HOT WATER CIRC - HIGH PRESS
- - - - - - - - - - - - - - - VACUUM WASTE
- - - DOMESTIC TEMPERED WATER
- - - - - - - - - - - - - - - VENT
DOMESTIC TEMPERED WATER CIRC
WASTE
FLUE
SANITARY SEWER
FLUE VENT - CPVC
STORM
GAS
FOOTING DRAIN
COMBUSTION AIR - PVC
OVERFLOW RAIN LEADER
GAS, MEDICAL
RAIN LEADER
ARGON
- - - - - - - - - - - - - - - PUMPED STORM DRAIN
CARBON DIOXIDE
- - - - - - - - - - - - - - - STORM DRAIN
HELIUM
NON-POTABALE
INSTRUMENT AIR
- - - DEIONIZED WATER
INSTRUMENT AIR INTAKE
- - - - - - - - - - - - - - - IRRIGATION WATER
LAB AIR
- - - NON POTABLE COLD WATER
LAB AIR INTAKE
- - - - - - - - - - - - - - - NON POTABLE FILTERED WATER
MEDICAL AIR
- - - - - - NON POTABLE HOT WATER
MEDICAL AIR INTAKE
- - - - - - NON POTABLE HOT WATER 140
MEDICAL VACUUM
- - - - - - - - - - - - - NON POTABLE HOT WATER CIRC
MEDICAL VACUUM EXHAUST
- - - - - - - - - - - - - NON POTABLE HOT WATER CIRC 140
NITROGEN
- - - - - - - - - - - - - - - NON POTABLE TEMPERED WATER
NITROUS OXIDE
- - - - - - - - - - - - - - - NON POTABLE TEMPERED WATER CIRC
OXYGEN
- - - REVERSE OSMOSIS WATER
WASTE ANESTHETIC GAS DISPOSAL
- - - REV. OSMOSIS/DEIONIZED WATER
WASTE ANESTHETIC GAS DISPOSAL EXHAUST
- - - TRAP PRIMER
- - - TRAP PRIMER UNDERGROUND
PLUMBING PIPING MATERIAL SCHEDULE
LOCATION PIPING
SIZE
MATERIAL (FOOTNOTE)
JOINT
PEX (a, d)
MFR APPROVED
DOMESTIC WATER
1/2" TO 1"
COPPER TYPE L (c, j)
PRESSED MECH JOINT
DOMESTIC WATER
1-1/4" TO 2"
COPPER TYPE L (c, j)
PRESSED MECH JOINT
PVC DWV/ABS SCH 40 (I, m)
SOLVENT CEMENT
ABOVE GROUND SANITARY WASTE
1-1/2" TO 4"
CAST IRON (k)
NO HUB
PVC DWV/ABS SCH 40 (m)
SOLVENT CEMENT
SANITARY VENT
1-1/2" TO 4"
CAST IRON (k)
NO HUB
INDIRECT WASTE
1/2" TO 2"
COPPER TYPE L 0)
PRESSED MECH JOINT
FOOTNOTES
(a) ACCEPTABLE FOR PLENUM USE IN SIZES 1/2" THROUGH 1".
(c) PRESSURE LIMIT OF 200 PSI
(d) LIMITED TO 80 PSI @ 200° F
0) PIPE TO BE SUPPORTED DIRECTLY ON HANGERS (NO INSERT OR SHIELD REQUIRED) INSULATION TO BE APPLIED OVER HANGERS
(k) STANDARD NO -HUB BANDS
(1) MAY NEED TO CONSIDER ACCOUSTICAL REQUIREMENTS
(m) FLAME/SMOKE SPREAD REQUIREMENTS MAY PRECLUDE USE
PIPING INSULATION SCHEDULE
PIPING
PIPE INSULATION
INSULATION
CONDUCTIVITY
TYPE
SIZE TYPE
THICKNESS
RANGE
COLD WATER OVERHEAD AND EXPOSED TO SIGHT
ALL FIBERGLASS
1/2"
0.21 - 0.27
COLD WATER WITHIN WALLS
NOT REQUIRED
HOT WATER AND RECIRC (UP TO 140°F)
1/2" - 1-1/4" FIBERGLASS
1"
0.21 - 0.28
1-1/2"-6" FIBERGLASS
1-1/2"
0.21 -0.28
ALL HOT WATER PIPING INSULATION SHALL MEET THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE, 2018 EDITION, TABLE C403.2.9
ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS
ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS.
PROVIDE A VAPOR BARRIER COVERING ON ALL COLD WATER PIPING INSULATION.
PROVIDE A COVERING FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING.
BACKFLOW PREVENTER SCHEDULE
MANUFACTURER & MAX DESIGN FLOW
WEIGHT
SYMBOL TYPE
SYSTEM SIZE
MODEL NO. PRESSURELOSS
NOTES
(LBS)
BFP-5 REDUCED
MED-3 MEDIVATOR WATTS 009-PC-QT 1/2" 17 PSI @ 5 GPM
6 1
PRESSURE
BFP-6 REDUCED
PRESSURE
MED-3 MEDIVATOR WATTS 009-PC-QT 1/2" 17 PSI @ 5 GPM
6 1
NOTES:
1. CONFIGURED WITH PRESSURE DIFFERENTIAL RELIEF VALVE LOCATED BETWEEN TWO INDEPENDENTLY OPERATED SPRING LOADED CHECK VALVES, TWO RESILIENT SEAT BALL VALVES AND FOUR RESILIENT
SEATED BALL TEST PORTS. BRONZE CONSTRUCTION, ASSE 1013 & NSF-61 LISTED.
DRAIN CONNECTION SCHEDULE
NO. DRAIN DESCRIPTION LOCAL CONNECTION
WASTE VENT
WOB-1 WALL MOUNTED OUTLET BOX - GUY GRAY TT200, DUAL OUTLET, QTY (2) 2" DRAINS, NO VALVES, WHITE POWDER COATED STEEL. 2" 1 1/2"
PLUMBING EQUIPMENT SCHEDULE
NO. EQUIPMENT DESCRIPTION
MV-2 MIXING VALVE - WATTS LFMMV, THERMOSTATIC MIXING VALVE, 1/2" SIZE, INTEGRAL INLET FILTER WASHERS AND CHECK VALVES, LEAD-FREE CAST COPPER CONSTRUCTION.
OWNER PROVIDED EQUIPMENT FIXTURE CONNECTION SCHEDULE
LOCAL CONNECTION
NO. OWNER PROVIDED EQUIPMENT INDIRECT WASTE WASTE VENT HOT COLD NOTES
MED-1 MEDIVATORS ENDOSCOPE WASHER/DISINFECTOR (1) V DRAIN, 1/2" 1/2" EXISTING, RELOCATE
(2) 1/4" AIR TANK PURGE
MED-3 MEDIVATORS ENDOSCOPE WASHER/DISINFECTOR (1) 1" DRAIN,
(2) 1/4" AIR TANK PURGE
1/2" 1/2"
NOTES
1. INSTALL RP BACKFLOW ON DHW AND DCW CONNECTIONS. INSTALL MIXING VALVE. SEE MEDIVATORS PIPING DETAILS ON SHEET TP6.01.
2. PROVIDED WITH FACTORY WATER FILTERS.
NEW, 1, 2
PLUMBING GENERAL NOTES
1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE PLUMBING CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO
VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2018 EDITION OF THE UNIFORM PLUMBING CODE AS AMENDED BY THE STATE OF WASHINGTON.
3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS.
4. SLOPE ALL WASTE PIPING AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING WASTE PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS
INDICATED ON DRAWINGS).
5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH SECTION 313 AND TABLES 313.3 AND 313.6 OF THE 2018 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS.
6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL.
7. FOR EXACT ROUGH -IN LOCATIONS AND ELEVATIONS OF PLUMBING FIXTURES REFER TO ARCHITECTURAL DRAWINGS.
8. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS.
9. CLEANOUTS SHALL BE INSTALLED SO THEY ARE EASILY ACCESSIBLE.
10. PLUMBING VALVES SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE PLUMBING
CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR.
11. THE PLUMBER SHALL PROVIDE AND LOCATE ALL REQUIRED FLOOR, WALL, AND FOOTING SLEEVES.
12. WATER DISINFECTION TEST SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 609.9 OF THE 2018 PLUMBING CODE PRIOR TO FINAL APPROVAL OF PLUMBING PERMIT
13. ALL ITEMS IN THE DOMESTIC WATER DISTRIBUTION SYSTEM MUST SHOW COMPLIANCE WITH NSF-61 LEAD FREE REQUIREMENTS. DOCUMENTATION MUST BE AVAILABLE ON SITE.
CONTACT LIST
TITLE
NAME
COMPANY
PHONE NUMBER
EMAIL
SENIOR DESIGN ENGINEER
CHRIS LEE
MACDONALD MILLER
206-768-4266
CHRIS.LEE@MACMILLER.COM
PROJECT MANAGER
JAKE BURSTEIN
MACDONALD MILLER
206-225-6723
JAKE.BURSTEIN@MACMILLER.COM
HEALTHCARE PROJECT EXECUTIVE
LOGAN ORDONA
MACDONALD MILLER
206-768-4012
LOGAN.ORDONA@MACMILLER.COM
PLUMBING FOREMAN
FRANK TINNIN
MACDONALD MILLER
206-571-9813
FRANK.TINNIN@MACMILLER.COM
G.C. PROJECT MANAGER CRYSTAL LASNIER
BN BUILDERS
PLUMBING SCOPE OF WORK
CRYSTAL.LASNIER@BNBUILDERS.COM
PHASE 1 SCOPE: RELOCATE MEDIVATORS SCOPE WASHER MED-1 FROM INSTRUMENT PROCESSING ROOM W6017 TO A TEMPORARY LOCATION IN DECONTAM ROOM W1268. INSTALL THE FOLLOWING TO
SUPPORT SCOPE WASHER MED-1 IN ROOM W1268: (2) RP BACKFLOWS, (1) MIXING VALVE, (1) WATER FILTER, DOMESTIC HOT AND COLD WATER PIPING. SCOPE WASHER SHALL INDIRECTLY DRAIN TO THE
EXISTING FLOOR DRAIN IN ROOM W1268.
PHASE 2 SCOPE: INSTALL THE FOLLOWING TO SUPPORT (2) SCOPE WASHERS IN ROOM W6017: (4) RP BACKFLOWS, (2) MIXING VALVES, (2) WATER FILTERS, (2) WALL OUTLET BOXES, DOMESTIC HOT AND COLD
WATER PIPING, WASTE AND VENT PIPING. RELOCATE SCOPE WASHER MED-1 FROM ROOM W1268 TO ROOM W6017. INSTALL NEW SCOPE WASHER MED-3 IN ROOM W6017. SCOPE WASHERS SHALL INDIRECTLY
DRAIN TO THE WALL OUTLET BOXES.
GENERAL SHEET LIST - PLUMBING
SHEET
UMBER SHEET NAME UMBER SHEET SHEET NAME
TP0.01 SCHEDULES
TP2.01 1ST FLOOR PARTIAL PLAN
DP2.06 6TH FLOOR PARTIAL DEMO PLAN
TP2.06 6TH FLOOR PARTIAL PLAN
TP6.01 DETAILS
LEGAL DESCRIPTION
PARCEL NUMBER: 00580700002500
LEGAL DESCRIPTION: SOLNERS 5 ACRE TRACTS BLK 000 D-00 - N 1/2 OF TRS 27 & 28 & S 1/2 OF TRS 25 & 26 TGW TH PTN OF VAC 10TH ST SE (FORMERLY 216TH ST SW ADJ THRTO) & TGW TH PTN OF TR 29 SD
PLAT LY WLY OF FDL - COM AT NWCOR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESC TH SLY TAP 35.44FT FIR SW CR OF SD TR 29 AS MEAS ALG S BDY SD TR & TERM OF LN HEREIN DESC (PER
CITY EDM BLA REC AF NO 199909155005)
21 6th St SW
215th St SW
SITE
o
-
216th St SW
Q
_0
c
N
218th
SW
(D
c
S�
r`
220th St SW
N VICINITY MAP
NO SCALE
om
m
-
z
Q�
C)
00
O
C
G
E U)
)u_
co
O
U)
�0,
E
O
~
=�
A
C
J
¢'C.0
Z
C
U_
_j
Q
Zo
N
❑
LL
c:
w
Q
❑
66
Z
0
w
w
Q
z
0
0. 0.
Ow
Q Z
w
pC
Lu J
2i Q
U) C)
0� w
w
Z Cn
O N w�
a) �� O
0 �W LL
Q 0
w
0�� w w
C w r° z =
C)2 U)
U/ N L1J U)
ENGINEER: LAST REVISED:
C LEE 02-21-22
CHECKED BY: DATE PLOTTED:
T BOVEY 02-21-22
CAD: ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212478-00
SHEET NUMBER:
TPO.01
a
w
DCW POC AT
kNICAL ROOM
I �
3/4" DCW '
3/4" DHW
i I
i
i
� I
i
i
it
i
i
I
i
I
I '
I ,I
I
I �
I
INSTALL TEMPORARY DCW &
DHW BETWEEN MECH RM
AND RM W1268. i
i
I
I ,I
i
I
i
i
I
i
E12070 i
I
LL
i
I
I i i
i
I
I
I
I
I
I
I
a
I
I
I
I
I
U I
I
I
W 1260
STERILE
STORAGE RM.
W1268
DECONTAMINATION
AREA
I
I
I
I
TEMP LOCATION OF
MEDIVATORS SCOPE
WASHER MED-1 DURING
PLUMBING WORK ON
6TH FLOOR
4 ?o
TP6.01 y o (E) FD
� N
I
I
AREA OF WORK
I
C7
MAIN INPATIENT
WORK AREA
PLUMBING GENERAL NOTES
1. TEMPORARY DCW AND DHW PIPING MATERIAL SHALL BE PEX.
2. MEDIVATORS SCOPE WASHER MED-1 SHALL BE TEMPORARILY
RELOCATED FROM ROOM W6017 TO ROOM W1268.
3. REMOVE TEMPORARY DCW AND DHW PIPING BETWEEN ROOM
W1269 AND THE MECHANICAL ROOM ONCE SCOPE WASHER
MED-1 IS RELOCATED TO ROOM W6017.
z
1 /4" = 1'-0"
00 �
—
z
Qco
0
0
�CD
�
�oEC/)
J)
LL ���C)
Co
0
U)
EE
U)o0Q
0,E�
O=
°'
0
J
Z
C
°o
U_
J
Q
N
0
j
c:
� EL
I I I I I I I I
w
0
66
z
0
w
I I I I I I I I w
Q
0
z
0
I I I I I I I I ly-
0. 0.
O Lu z
Q Z
W
pC J
wJ Q
(D
2i Q -
U)C
z
W �� 0-
Lu
Z�
O N (.0
200 O� O
0 �Q< O LL
w J�
ow
Cw�°z ��
2 ° v,U)
U/ U) N Wqr-- ow U)
ENGINEER: LAST REVISED:
C LEE 02-21-22
CHECKED BY: DATE PLOTTED:
T BOVEY 02-21-22
CAD: ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212478-00
SHEET NUMBER:
TP2.01
w
a
N
(0
N
LL
o
I
I
I
I
I
AREA OF WORK
I
I
EXISTING MEDIVATORS SCOPE WASHER TO BE
TO 1 ST FLO(
DISASSEMBLE PIPING LOCATED ON THE SIDE OF THE HOOD CABINET
AND SAVE THE FOL OWING EQUIPMENT FOR REUSE:
PRESSURE GAUGE
MIXING VALVE
WATER FILTER ASSEMBLY ITH PRESSURE REDUCING VALVE
REMOVE (2) PRESSURE REDUCING VALVES FROM INSIDE THE HOOD CABINET J
AND SAVE FOR REUSE. HOOD AN CABINET TO BE DEMOED BY OTHERS.
STAINLESS STEEL COUNTER TO BE MODIFIED BY OTHERS TO ACCOMMODATE THE NEW SCOPE WASHER
W6033
z
Q
LL
O
>
O
C9
E
o ILL
7
J
cn LL
O
� 0
O
CD
Q
0
Oa)
�00_
a)Q °'
�'
� Z
J
�
UU
°C:)
U
Z N
0
LL
>J
r n
I I I I I I I I w
Q
0
z
O
LU
Ow
Qz
w
pU
wJ
�Q
U)U
00
z
w
O2
N
_�:�
0C/)a<
wC)=
U
LLJ 0
r-z
�0
v /
C+ / N LUJ
ENGINEER:
LAST REVISED:
C LEE
02-21-22
CHECKED BY:
DATE PLOTTED:
T BOVEY
02-21-22
CAD:
ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212478-00
SHEET NUMBER:
DP2.06
w
O
LL
0
w
Z)
C)
C)
KEY PLAN
1 1 /4" = 1'-01, 1
w
1. DCW AND DHW PIPE MATERIAL SHALL BE
COPPER WITH PRESSED FITTINGS.
N
(0
N
LL
o
Z
Q
LL
O
O>
C9
0-)
E
o ILL
7
J
cn L�
0
� 0
O
CD
Q
0
Oa)
�_
°'
a)00
Q`��'z
�
J
�
U
U
°�
U
� N
0
LL
>J
r n
I I I I I I I I
LU
Q
z
O
L
LU
I I I I I I I I w
Q
0
z
O
LU
ry
Ow z
�-- ~ Q
Qz J
>w n
pU J(DwJ Q
UU ry
0p Q`
w
Z� (.0�
O N
0 O�
p cn ; Q O
w—Q� J�
proLL
Uwcoz =J
C)
ENGINEER: LAST REVISED:
C LEE 02-21-22
CHECKED BY: DATE PLOTTED:
T BOVEY 02-21-22
CAD: ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212478-00
SHEET NUMBER:
TP2.06
w
O
LL
0
w
Z)
U)
U)
KEY PLAN
1 1 /4" = 1'-01, 1
LIU
NOTES _ _
1. INSTALL RP BACKFLOWS NO HIGHER THAN 3/4" DCW 1Aw
60" AFF. 3/4" DHW DHW
2. INSTALL BYPASS VALVE AND TEMPERED - - - - - - - - - - -
WATER SHUTOFF VALVE IN EASILY
ACCESSIBLE LOCATION. DO NOT INSTALL
BEHIND SCOPE WASHER.
3. PROVIDE ADEQUATE CLEARANCE AROUND i I 1/2" DCW o
THE WATER FILTER UNIT FOR FILTER 1/2" TEMPERED WATER SHUTOFF VALVE 1/2" DHW
CHANGE OUT. a s o
4. TERMINATE INDIRECT DRAINS WITH MIN 1" MEDIVATORS PRV
AIR GAP.
MEDIVATORS WATER FILTER UNIT
T
1/2" VALVE &CAP FOR FUTURE PUMP I 1/2" TEMPERED I T
ELECTRICAL WATER TO SCOPE
DISCONNECT WASHER,
BYPASS VALVE, NORMALLY CLOSED SWITCH
TERMINATE WITH
Li
PRESSURE GAUGE, 0-100 PSI i l HOSE CONNECTION.
TEMPERATURE GAUGE, 0-200°F (TYP)
I
THERMOSTATIC MIXING VALVE, SET TO 95°F.
.................................................
ACCEPTABLE TEMP RANGE 95°F ± 4°F
I _ _
I
I�I I I
I I I
STERIS
1/2" PRV, CAVIWAVE PRO
ACCEPTABLE DYNAMIC WATER ULTRASONIC CLEANER
PRESSURE OF 40-87 PSI (TYP 2)
I
BFP-1, 1/2" RP BACKFLOW I ��
BFP-2, 1/2" RP BACKFLOW
FLOOR DRAIN
OUTLINE OF MEDIVATORS SCOPE WASHER.
..]
PIPING TO BE INSTALLED BEHIND THE SCOPE WASHER.
RP BACKFLOW DRAIN, RUN FULL SIZE TO INDIRECT DRAIN 4"W 1/2" BYPASS LINE DRAIN, RUN TO INDIRECT DRAIN
AT EXISTING FLOOR DRAIN AT EXISTING FLOOR DRAIN
1ST FLOOR TEMP LOCATION, MEDIVATORS SCOPE WASHER - PLUMBING DETAIL
TP6.01 SCALE: 1/2" = 1'-0"
NOTES
1. INSTALL RP BACKFLOWS NO HIGHER THAN
60" AFF.
2. INSTALL BYPASS VALVES AND TEMPERED
WATER SHUTOFF VALVES IN EASILY
ACCESSIBLE LOCATION. DO NOT INSTALL
BEHIND MEDIVATORS SCOPE WASHER.
3. PROVIDE ADEQUATE CLEARANCE AROUND
THE WATER FILTER UNIT FOR FILTER
CHANGE OUT.
4. TERMINATE INDIRECT DRAINS WITH MIN 1"
AIR GAP.
2" W C(
BUILD
MEDIVATORS
SCOPE WASHER
MED-1
0 0 0
MEDIVATORS
SCOPE WASHER
MED-3
MEDIVATORS SCOPE WASHERS - EQUIPMENT LAYOUT DETAIL
1" DCW
1" DHW -
1/2" DHW
1/2" DCW
II
I
SCALE: 1/2" = 1'-0"
FIELD VERIFY POC TO EXISTING VENT
I
I
II
I II
1/2" DHW
1/2" DCW
I
II
II
DUAL OUTLET BOX WITH (2)
2" DRAIN CONNECTIONS (TYP 2)
W (TYP 4)
TRAP
MEDIVATORS SCOPE WASHER - IN -WALL PLUMBING DETAIL
SCALE: 1/2" = 1'-0"
MEDIVATORS PRV,
MEDIVATORS WATER FILTER UNIT, PROVIDED WITH MEDIVATORS SCOPE WASHER
PROVIDED WITH MEDIVATOR (TYP) (TYP)
1/2" VALVE & CAP FOR FUTURE PUMP (TYP)
TEMPERATURE GAUGE, 0-200°F (TYP)
PRESSURE GAUGE, 0-100 PSI (TYP)
1/2" PRV,
ACCEPTABLE DYNAMIC WATER
PRESSURE OF 40-87 PSI
(TYP 4) P T I I
rI
IT I
THERMOSTATIC MIXING VALVE, SET TO 95°F. P T
ACCEPTABLE TEMP RANGE 95°F ± 4°F I ICI
(TYP) II P T I I I1
II TI
I I Ir P T I� I I
I
r --
BFP-1, 1/2" RP BACKFLOW
BFP-2, 1/2" RP BACKFLOWI�pa—
I
BFP-5, 1/2 RP BACKFLOW // I
BFP-6, 1/2" RP BACKFLOW
I I II
WALL OUTLET BOX (TYP)
1/2" BYPASS VALVE,
NORMALLY CLOSED
1/2" TEMPERED WATER SHUTOFF VALVE
(TYP 2)
I
1/2" TEMPERED WATER TO SCOPE WASHER,
TERMINATE WITH HOSE CONNECTION.
HOSE AND HOSE ADAPTER PROVIDED
WITH MEDIVATOR. (TYP)
RP BACKFLOW DRAIN, RUN FULL SIZE TO INDIRECT DRAIN AT OUTLET BOX (TYP) -J I DRAIN HOSE FROM MEDIVATOR,
J RUN TO INDIRECT DRAIN AT OUTLET BOX.
1/2" DCW, 1/2" DHW (TYP) DRAIN HOSE PROVIDED WITH MEDIVATOR. (TYP)
1/2" BYPASS LINE DRAIN, RUN TO INDIRECT DRAIN AT OUTLET BOX (TYP)
MEDIVATORS SCOPE WASHER - WALL MOUNTED PLUMBING DETAIL
SCALE: 1/2" = 1'-0"
rVl/7
�
O CO
z
Q I�
0
0
�
C9
�
;oECf)
0 ILL
J
U) li
O
_�
m 0
O
Uo0Q
0
5
co
E�
O
a0
� Z
J
�
U
oo
J
Q
N
o
ILL
I I I I I I I I w
H
Q
0
cj
z
O
w
0. 0.
Ow
Z
w
pU(DwJ
C Q
c
U)U �
C) w
w Lu
Z�
O N
C)
0 O
0�>Q LL
LL J <
�I— Q w
Uwrco 0
_z 3:'-� w � ) C/)c0
NW 0
�/�+
ENGINEER:
LAST REVISED:
C LEE
02-21-22
CHECKED BY:
DATE PLOTTED:
T BOVEY
02-21-22
CAD:
ISSUE DATE:
F MAMERTO
DRAWING NUMBER:
D-3579-77212478-00
SHEET NUMBER:
TP6.01