Loading...
APPROVED ENG PLN Plot Plan-06-25-20zone ES-8 Corner N Flagg setbu Rc�d *- Prout _ 2 ' _._._.. E= 118' Sides __..7.5'.....-._ N= 7.5' / S=109' Rear W= 15 - Other . Heist 21'-3" * Setbacks shown are to the ADU structure. Owners: Treece Torre & Kendra Address: 8104 219t1i St SW Edmonds, WA 98026 Tax Parcel#: 27043000104100 IMPERVIOURS SURFACE CALCULATIONS Existing Building Roof Outline: 2746sf (const. 1959) Existing Garage: 2152sf Existing Driveway & Patio: 4375sf. Existing Gravel area: 1761sf PLOT PLAN Scale: 1"-20' BLD2020-0266 APPROVED BY PLANNING Jun 03 2020 HEIGIHT CALCULATIONS A=94 B =100 SEWER TO BE C=97 INSTALLED ABOVE D =102 EXISTING PERFORATED AVG GRADE = 98.25 STORM PIPE ACTUAL =119.5 ADU replace 1114sf of gravel area MAXIMUM 123.25 Remaining gravel area to be 6475ft LOT COVERAGE: 4898 (20%) without ADU Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance LOT COVERAGE: 6112 (25%) with ADU of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which LOT AREA: 24025sf is outside the scope of the permit application, regardless LOT SLQP. 4% of whether such building, structure or condition is Trees Filter Fencing shown on the site plan or drawing. Such building, Existing rock wall structure or condition may be the subject of a separate d S enforcement act t9 !C3 V) r Storm Drain Upper Deck Existing Sewer ADU sewer 4 AV RESUB Jun 25 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Roof overhang shall not extend more than 30" into required setback. Any support posts must also meet setback requirements Existing Fence i ADU 7o4 sf i 1.1 ADU connecting i to existing structure ' 1Ar( C Sewer clean out Tree Pond *REQUIRED f Existing Rockery y water shut off J Water line copper w/tracer temporary stockpile location Ivd � - -. -- - - - - - = Existing Patio �t i W r Water service line for ADU Existing i -- - --1- - - - - ��- Patio I I Entry Existing main floor 2098 sf • lower floor 1606 sf Covered Entry f l l� electrical panel I Existing I Patio /+ 97' %D' JA Gravel Existing " 5/8minus . Existing 3 C7• ockery 1+1� Existing Existing Tree Fence Shed 120 sf LEGEND fil W c W a� Existing Garage i 1988 sf 4. ao 3C Existing O D Driveway + IM Construction entrance -f L1/ M i Parking — T i + 101 water shut off 1" upsized Water Meter Stockpile will be covered within 24 hours 155 Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. -Filter socks will be added to any on -site or downstream catch basins from the i construction site. Incorporated and reference City detail ER-902 -All disturbed areas to be compost amended per 2014 SWMMWW BMP T.5.13. Hose Bib / -All existing stormwater management systems shall be protected during the entirety of the project PATCH FROM TAP -install and maintain all TESC measures according to approved plans, TO BE RESTORED City of Edmonds standard details, and all other measures that may be ENGINEERING DIVISION PRIOR TO FINAL. required during construction APPROVED AS NOTED NGriggs 07/14/2020 Center of Right of way OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. Water meter upsized to 1" with a 1 W service line I ss DATUM PT. +100' Top of SS Manhole Cover \\ OWNER/CONTRACTOR IS RESPONSIBLE FOR N EROSION CONTROL AND DRAINAGE Y St