PLN APPROVED PLOT PLAN 5.21.20Owners: Treece Torre & Kendra
Address: 8104 2191:h St SW Edmonds, WA 98026
Tax Parcel#: 27043000104100
IMPERVIOURS SURFACE CALCULATIONS
Existing Building Roof Outline: 2746sf (const.1.959)
Existing Garage: 2152sf
Existing Driveway & Patio: 4375sf,
Existing Gravel area: 1761sf
ADU replace 1114sf of gravel area
Nothing in the permit approval process shall be
interpreted as allowing or permitting the maintenance
of any currently existing illegal, nonconforming or
unpermitted building, structure or site condition which
is outside the scope of the permit application, regardless
of whether such building, structure or condition is
Zom RS-8 F!a N
Sethmkl EST
RESUB
�
FrontSides
PLOT PLAN s�a� ---
-z,5_ _.._�_
N= 7.5' / S=109'
May 21 2020
Scale: q n-20� ].ea' 15' _�__.,�•
1 —
_
W- 15'
CITY OF EDMONDS
DEVELOPMENT SERVICES
Other
DEPARTMENT
He€ght 25�........._�
21'-3"
* Setbacks shown are to the ADU structure
HEiGIHT CALCULATIONS
A=94
8=100
C=97
D-102
AVG GRADE = 98.25
ACTUAL = 119.5
MAXIMUM 123.25
APPROVED BY PLANNING
Jun 03 2020
LOT COVERAGE: 4898 (20%) without ADU
LOT COVERAGE: 6112 (25%) with ADU
LOT AREA: 24025sf
shown on the site plan or drawing. Such building, LOT SLOP: 4%
Trees
structure or condition may be the subject of a separate Filter Fencing
Trees
enforcement action.
Existing rock wall /
� 5 �' 1
m
a
v
Storm Drain
Upper Deck
l :.'Y -.
+ t � T.
Existing Sewer
ADU sewer 4" PVC
Roof overhang shall not extend more than 30"
into required setback.
Any support posts must also meet
setback requirements
ADU 704 sf
Sewer clean out
Tree Pond Er
Existing Rockery water shut off
h
Water line copper w/tracer
Existing ;w
Patio
t r
Existing _ _ __ - -- - - _ _
'- Patio I Entry
I
try I U
Existing main floor 2098 sf a
Sower floor 1606 sf
C.
Q
Covered i
i
� I Entry �
electrical panel`
� l Existing
I -• � l Patio
Existing = '
Gravel 5/8minus
st
ockery
Existing
Garage
� 1988 sf
E �
a
Existing
Fence
ADU connecting
to existing structure
temporary stockpile location
r— Water service fine for ADU
.
. cD
an
c
a Existing
sD
Driveway +IOZ
Construction entrance �
AA
water shut off
Existing Existing Tree .
Fence Shed 120 sf
i
Parking
40
1"upsized
Water Meter Stockpile will be covered within 24 hours .
LEGEND -Filter sacks will be added to any on -site or downstream catch basins from the
- � construction site. Incorporated and reference City detail ER-902
� Q -All disturbed areas to be compost amended per 2014 SWMMWW BMP T.5.13. Hose Bib -All existing stormwater management systems shall be protected during the entirety of the project
' -Install and maintain all TESL measures according to approved plans,
City of Edmonds standard details, and all other measures that may be
required during construction
Water meter upsized to 1" with a 1 %" service line
I ss DATUM PT. +100'
Top of SS Manhole Cover
Center of
.Right of Way �. 3
I v7
!I N
r
a+
J Qi
�r