APPROVED PLN BLD BLD2020-0965+Architectural_Plan+12.23.2020_10.29.29_AM+1961201GENERAL NOTES AREA CALCULATIONS GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), HEATED AREAS SQUARE FOOTAGE t INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE 2ND FLOOR 1532: AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE. MAIN FLOOR 2952 THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND TOTAL 4484 WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE j RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. NON -HEATED AREAS SQUARE FOOTAGE THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR GARAGE 982 DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND COVERED FRONT PORCH 220 WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING COVERED REAR PATIO 332 _ COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. d,-: r SITE WORK 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN - - WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND''s . t_�° -. WATERPROOFING. 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS - —-- -- - BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TOROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDEDRAWING INDEX_ I11 TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES.'*. 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER APPLICABLE CODE. MECHANICAL SHEET N0. DESCRIPTION _ ■ro 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN _ - 1� ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL Al COVER SHEET, INDEX, GENERAL NOTES CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND LOCAL CODES. A2 ENERGY CALCULATIONS - - -- J PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE A3 ELEVATIONS WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH a THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE A4 ELEVATIONS GARAGE FLOOR. A5 MAIN FLOOR PLAN' - — AND MOISTURE A6 2ND FLOOR PLANTHERMAL A7 BUILDING CROSS SECTIONS & DETAILS �r ,p - ., '.W - 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE A8 BUILDING CROSS SECTIONS ;•, •``... a ''`- .��?r;%er i x�a �,H' � - t' w OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON A9 BUILDING CROSS SECTION u+ PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. 2. APPLY 1 COAT MIN HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION S1 STRUCTURAL NOTES/SCHEDULES mow — WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE S2 STRUCTURAL DETAILS INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER S4 SHEAR WALL AND HOEDOWN LOCATIONS 1 I� •���,� �, � ���'' , , �, V � � �� "xf MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES S5 FOUNDATION PLANS ' AND OVER FOOTINGS. S6 MAIN FLOOR FRAMING PLANS - Pi* S7 2ND FLOOR FRAMING PLANS � w' W�� �.� ��� � FINISHES S8 ROOF FRAMING PLANS ;�; .. GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/81' TYPE "X" GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/81, GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND APPROVED BY PLANNING %s COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS ��LL SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF NO ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER STUCCO SHALL INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, 107xx 226TH STREET S.W., EDMONDS., WA 98026 Jan 14 2021 BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYMBOL LEGEND SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. CARBON MONOXIDE DETECTOR FIRESTOPPING 0 INTERCONNECTED 110v w/ BATTERY BACKUP C.O. CAN BE COMBINED w/ S.D. FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND O SMOKE DETECTOR INTERCONNECTED 110v w/ BATTERY BACKUP HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND S.D. THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING O EXHAUST FAN (VENT TO OUTSIDE) LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. O KEYNOTE 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL 101 DOOR SCHEDULE SYMBOL CAVITIES IN LINE WITH STRINGERS. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH 11 WINDOW SCHEDULE SYMBOL NON-COMBUSTABLE MATERIALS. MISCELLANEOUSTRITLE BLOCK E DESCRIPTION IN 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. SIM DETAIL SYMBOL 1 ` SIMILAR DETAIL Al O1 OBTAIN ELECTRICAL APPROVED — DETAIL NO. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. CARBON MONOXIDE SHEET NO. SIM PERMIT FROM PLANS MUST BE (R314) ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE 1 ! STATE LABOR & BEDROOMS. (R315) BUILDING CROSS SECTION A10 — DETAIL NO. ON JOB SITE 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE INDUSTRIES BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. SHEET NO. 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. Room name— ROOM NAME 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF City of Edmonds ALL WORK SUBJECT 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). TO FIELD Building Department linawwhat's helvw STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO INSPECTION F O R rr Call before you dig. LOCATE ALL UNDERGROUND UTILITIES. APPROVED Plans CODE COMPLIANCE City Of E Building Department r..... Work ..................................................................................................................: ..... ........................... NEW SFR .......................... Address 10729 ------------------------ ......................., 226TH ST SW LOT 2 ....................... r.............................................................................................................. Owner ' HELLEREN .............................................................................................................. r........................................................................ Approved Date 01 /13/2021 ----------------------------------------------------------------------------------------------= Building Official W. l� Approved By Fire .....................................................................................:::..... DFM17 PBrough Permit Number:BLD2020-0965 07/0,5/27 Reviewed: Approved. A residential fire sprinkler system is required. A recommended flow -through dE sign will meet specifications and reduce equipment and continuing maintenance requirements. ECDC19. 5.020132. Provide a minimum combination water service of one inch (1") meter and one and one half (11/2") service line, or show that domestic and fire protection needs can be met with a smaller service. DFM17 U Z� co �co co Q > U IL Y = WaN oJ � ��� = V � � o Z �o.� LU N N o°� uu m —1 0 W a 2 H O U C O i, �1fl11111h L i 1J:1� j14�1� - L y N `_ O N L ---,a N O OJT N C C l9 O O Q J w O U L L N O O Q O. Nam 0 L~ O O U E 0 U i0 C T N O O Y OULLa O 2�i'mcN OL^''`mU�EN a 0 O w g W o o E U o >.N m 3 c m 0 U J J F tl1 O_ LO U d 0 ;_. - y -OO 0 LUOmoada E� ,, a`Jr �a`J F Z n_ m a� of E RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1-0 CV z C] CIO °' Q W Q z LU0 W z LU W LU LU LU o C) J Z N p N LJJ X T W 0 i ca 0 0 6 Z PROJECT NO. 180000 DESIGNED BY TL DRAWN BY TL & RIM CHECKED BY TL SHEET NO. Al PRINT DATE 4/11/2020 7:02:25 PM R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2015 WASHINGTON STATE ENGERY CODE. R402.2 FENESTRATION (PRESCRIPTIVE) R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U- factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4 R404.1 LIGHTING EFFICACY MIN. OF 75% OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS. M 1507 MECHANICAL VENTILATION M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUESTROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4, M1507.3.5, M1507.3.6 OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 4. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." 5. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: 5.1. THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. 5.2. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. 5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION 403.8.5.1. 5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. 5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. 5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. 5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING. M1507.3.4 WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE -HOUSE VENTILATION SYSTEM. M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916 OR AMCA 210. M1507.3.4.2 FAN NOISE. WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 2O09). REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M1507.3.4.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1. M1507.3.4.4 OUTDOOR AIR INLETS. OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. PROVIDE NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. 5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. TABLE 1507.3.3 (1) CONTINUOUS WHOLE HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATES FLOOR AREA BEDROOMS* (SQ. FT.) 0-1 2-3 4-5 6-7 >7 < 1500 30 45 60 75 90 (IN CFM's) 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 >7500 105 120 135 150 165 TABLE 1507.3.3 (2) INTERMITTENT WHOLE HOUSE MECHANICAL VENTILATION RATE FACTORS RUN-TIME PERCENTAGE IN EACH 4-HOUR SEGMENT 25% 33% 50% 66% 75% 100% FACTOR 4 3 2 1.5 1.3 1.0 THIS PLAN USES AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM WITH TIMER(s). TOTAL HEATED FLOOR AREA = 4484 SQ. FT. BEDROOMS = 4 WHOLE HOUSE VENTILATION SIZE = 90 CFM X 4 (25% PER 4-HOUR) = 360 TOTAL CFM FAN(s) SIZE. INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN. MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE SIMULTANEOUSLY. TWO FANS TO BE USED AT 180 CFM EACH. ONE UP, ONE DOWN. 2015 WASHINGTON STATE ENERGY CODE MISC. ENERGY CODE NOTES A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel by the builder or registered design professional. The certificate shall be completed by the builder or registered design professional and shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, below -grade wall, and/or floor) and ducts outside conditioned spaces; U-factors for fenestration and the solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service water heating equipment. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed b the art conducting the test and provided to the code official. Testing shall be performed 9 Y party 9 P 9 at any time after creation of all penetrations of the building thermal envelope. Where the primary heating system is a forced -air furnace, at least one thermostat per dwelling unit shall be capable of controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different times of the day. Specifics and Exceptions see SEC. ALL DUCTWORK SHALL BE SEALED AND TESTED PER R403.2.2. WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH R-10 RIGID INSULATION EXCEPT IN SITUATIONS WHERE STRUCTURAL BEAM SIZE REQUIREMENTS OVERRIDE. ALL APPLIANCES SHALL BE U.L. LISTED. WHOLE HOUSE FANS Whole house ventilation fans shall be installed so as to run simultaniously. EXHAUSTFANS Exhaust fans to terminate at building exterior with clearances per SRC M1506.2 (min. 3 ft to openings) and for clothes dryer vent terminations to be per M1502.3 (3 ft to bldg. openings). ALL FENESTRATION SHALL BE NFRC CERTIFIED. 2x6 TOP .W.B. AID R-10 INSULATION �LLED IN CAVITY (EEN ER PER _OW, FINISH & TRIMS HEADER INSULATION 1 1 /2" = 1 r-0" FENESTRATION CALCULATIONS VERTICAL GLAZING 647 SF LESS EXEMPT GLAZING -138 SF PLUS GLAZED DOORS 264 SF PLUS OTHER EXTERIOR DOORS 21 SF TOTAL FENESTRATION: 794 SF NOTE: SEE SHEETS A7 FOR ADDITIONAL INSULATION LOCATIONS AND DETAILS, PRESCRIPTIVE ENERGY CODE COMPLIANCE TABLE R402.1.1 FOOTNOTES Prescriptive Energy Code Compliance for All Climate Zones in Washington Prefect Information Contact Information HELLEREN RESIDENCE LEIF AND KIM HELLEREN This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones R-Values U-Factors Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazer! Fenestration SHGCb'e nla n/a Ceiling, 49i 0,026 Wood Frame iflWall" n 21 int 0.056 Mass Wall R-Vaiue' 21 /21 n 0.056 Floor 309 0.029 Below Grade Wall'm 10/15/21 int + TB 0.042 Slab" R-Value & Depth 10, 2 ft n/a " I able K4U2.1.1 and ( able K402.1.:3 Footnotes included on Nage 2. Date Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. CI 2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. n 3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑ 4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Ontion DesCrjDtjon Cro.ditfs) la Efficient Building Envelope 1 a 0.5 1 b Efficient Building Envelope 1 b 1.0 1 c Efficient Building Envelope 1 c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1,0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions ❑ a 0.5 p 1.0 Li ® 0.5 0 1.5 1200 kWh 0.0 3.50 Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. "10/15/21.+TBr' means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TBr' shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. ' Reserved. h Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. 'Reserved. k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. ENERGY CREDITS 2a AIR LEAFAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour 1naxilllunl and All whole house veatilationn requirenneilts as detennnilied by Section M1507.; of the International Residential Code shall be inlet with a high efficiency fan (maximinn 0.35 watts./cfin). not interlocked with the Au -race fain. Ventilation systems using a furnace including an ECM motor are allowed. provided that they are controlled to operate at low speed in ventilation only mode. To qualify to claim this credit, the building permit drawings shall specify the option beulg selected and shall specify the maximtzln tested building air leakage and shall show the qualifying ventilation system. 3 a HIGH EFFICIENCY HVAC EQUIPMENT 3 a: t. U Gas. propane or oll-fired ftliinace with nnlllinnum diFUE of 94%, or Gas, propane or ailed -fired boiler with rnninilnum AFUE of 92% To qualify to claim this credit, the building pel�init drawings shall specify the option being selected and shall specify the heating equipment Type and the lnuiimunn e ui inept efficiency. 5a EFFICIENT WATER HEATING 5a: All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less.` To qualify to claim this credit, the building perinit drawings shall specify the option being selected and shall specify the maximum flow bates for all showerheads, kitchen sink faucets. and other lavatory faucets. 5c EFFICIENT WATER HEATING 5c: 1 Water heating system shall include one of the following: Gas, propane or oil water heater With a iniaimum EF of 0.91 01' Solar water heating supplementing a miuunium standard water heater. Solar water heating Will provide a rated lni imi llin savings of 85 therms or 2000 kA7h based on the Solar Rating and Certification Corporatiou (SRCC) Aullttal Performance of OG-300 Certified Solar Water Heating Systems or Electric heat punnp water heater with a nnininnum EF of 2.0 and meeting the standards ofNEE A's Northern Climate Specifications for Heat Puinp Water Heaters To qualify to claim this credit. the building perluit drawings shall specify the option being selected and shall specify the water heater equipment type and the lininilnnilnl equipment efficiency and, for solar water heating systems, the calcination of the miniinuln energy savings. HEATING SYSTEM SIZE Contact Information Heating System Type: F All Omer Systems Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions'. Design Temperature lostrucuons + Design Temperature Difference (AT) 46 Edmonds w IJ .'a7 = Md°ar f70 degraesl • Ouldoar ❑eslgn rerrrp Area of Building Conditioned Floor Area rnszructrons Conditioned Floor Area (sq ft) 4,484 Average Ceiling Height Conditioned Volume lnstruetion= Average Ceiling Height (ft) 9.1' 40,804 Glazin-gand Doors U-Factor X Area = UA nsm).tinns tl-n �c•. ,. 0.300 794 238.20 Skylights U-Factor x Area = UA 11(,r,c 0-50 32 16,00 Insulation Attic U-Factor x Area - UA natru .Barr_ I R T 0-026 351 9,13 Single Rafter or Joist Vaulted Ceilings U-Factor x Area UA inssructipn>: IN R-36Vented 0.027 3,222 J 86.99 Above Grade Walls fsaa Figure it U-Factor X Area UA Insmirlians R-21 Intermediate 0.055 4,771 267.18 Floors U-Factor X Area UA lnsiructions 0,029 3,653 105-94 Below Grade Walls isee Figure ri U-Factor X Area UA l�ratruc liur'^ No Below Grede Walls io 7 0. 028 0� � t}ris project. ..A --_.-.-. Slab Below Grade fsee Figure 1) F-Factor X Length UA In siruclion:i k No Slab Sebw Grade in this project. 0.303 F --- Slab on Grade (see Figure 7) F-Factor X Length UA rvsl r u ctl o n t. Slab Grade in T No an this project. -- Location of Ducts Duct Leakage Coefficient tJn[onditidned Spa[e �► 1.10 Sum of UA 723.43 Envelope Heat Load 33,278 Btu ! Hour Ficture 1. sum ofUAX;.r Air Leakage Heat Load 20,272 Volume O..6X6rX.07e Btu 1 Hour auo.; Ur..; • Building Design Heat Load 53,550 Btu / Hour Air Leakage + Envelgpa Hsaf Loss arrow ,rode Building and Duct Heat Load 58,904 Btu I Hour Ducts iA unconditioned space: Sum of Buddirig Heal Loss X 7.10 Ducts in condMoned space: Sum of 80ding ilea! Loss X t Maximum Heat Equipment Output 82,466 Btu l Hour 8uifding and Ducf Neal Loss X 1A0 for Forced Air Fumace 8uifd09 and Duns Heal Loss X 7.25 for Nee! Pump U Z co �co co CM Z �o a U J0� �0�o M COwC Z coO, W �! @ 11W o Q) W m -1 p UJ n H E O U r + 'gin aD tr rr 111 Z V! [0 9L d >> N ^ N L N N N O Nam c� :5 o s~ o t U E c o �o�� mo���ye U 0< 0 U- 2 C (/1 L f0 U s E N O W g w o o _u c U o U J J F F a_2 ZEIm0 RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W *_O N Z 0 CD °' Q W Z W � W Zvi L U W I-- � LLJ UJ W o J Z N mmi p N W W a� its 0 c O M O Z PROJECT NO. 180000 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A2 PRINT DATE 4/11/2020 7:02:46 PM ELEVATION NOTES PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36" WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1) ELEVATION KEYNOTES KEY VALUE KEYNOTE TEXT 39 40+ YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING 40 STANDING SEAM METAL ROOFING. COLOR AND STYLE PER OWNER SPECIFICATIONS 41 CONTINUOUS ALUMINUM GUTTER ON 5/4x6 FASCIA 42 BOARD AND BATTON: 1x3 BATTONS @ 16" O.C. ON HARDI-BOARD OR EQUIV. SMOOTH FACED BOARDS 45 FASCIA: 1x4 ON 5/4x10 (TYPICAL AT GABLE ENDS) 48 6" EXPOSURE HORIZONTAL BEVEL CEMENT BOARD SIDING WHERE INDICATED 55 5/4x8 CEDAR OR WHITE WOOD TRIM PER BUILDER SPECIFICATIONS. 59 5/44 CORNER TRIM 61 2x10 BELLY BAND w/ METAL FLASHING 67 WINDOW WRAP: 5/4x6 SIDE RAILS w/ 2x8 TOP RAIL AND 2x3 DRIP SILL OVER 5/48 TRIM. PROVIDE HEAD FLASHING OVER ALL WINDOWS NOT UNDER EAVES AND/OR EXPOSED TO WEATHER. 71 BOX FRAME POST BASE AND WHITE WOOD TRIMS o/ STRUCTURAL POST PER PLAN 72 STONE OR BRICK VENEER WHERE INDICATED 80 TEMP. GLASS STORE DOOR 81 TEMP. GLASS SLIDING PATIO DOOR. 83 PROVIDE 6" MINIMUM EARTH/WOOD CONTACT TEMP. GL. LOCKING DEADBOLD AT ENTRY DOOR CONCRETE LANDING AND STEPS PER I.R.C./I.B.C. 84 85 86 87 INSULATED STEEL OVERHEAD GARAGE DOOR. MAKE AND STYLE PER BUILDER/OWNER SPECIFICATIONS. ora;nEdge ,;. strip ;e44 WeatherSeal bowel applied rnemhrane r. + Step flashing taped and sealed Kick -oat flashing Kick-Qafandfascia taped and sealed I Sflingies Wall sheathing KICO'KOUT FLASHING DETAIL. Max. Hecht 411117 294' - 2 1 /4" 2ND FLOOR PLATE 11" Co Q 2ND FLOOR N - 280' - 9 7/8" MN rk MAIN rLUOR PLATE 2ND FLOOR PLATE v 288' -11 " 20 Eo v M N 2ND FLOOR TOP OF RIDGE _ - 293' - 8 1 /4" (40) (39) r m— 1-0 i�� III -- -- -- �� litiiii■i tiiii■ tiiii■ tiiii■ iii �I s ga ■.■ ■� ■■ ■■ ■■ ■■ Um ■■ _ .. ■■ ■■ ■■ ■■ ■■ I■ a I ow MERCE1 ■1■ MEMEL- - _ I I■I I I■ I I■I Il;I� -- DECORATIVE SHUTTERS WHERE INIDICATED - __ - -r- "% TEMP. GL. SKYLIGHTS (TYP. @ 6 PLACES) 3 1/4" = 1'-0" -TOP OF RIDGE 293' - 8 1 /4" V v 280' - 9 7/8" MAIN FLOOR PLAT v 279' - 7 1 /8" AL 67 — 59 \ / 48 ILI I 86 = �� ��lop 61 MAIN FLOOR 270'- 6" — — Max. H_ei hg t 294' - 2 1 /4" — _Average Grade 269' - 2 1 /4" iE�� E�l E�� E�l _m� 7- 7- 72 NORTH ELEVATION 3 1 /4" = 1'-0" U z — N 0 >_ 00 00 z E Q >Q > U IL Y 2 a- wa y ��� O V fM GO �O z 00 04 W o uu m _i 0 W a 2 H I� M fjlri .y M 'Ir 1 � _ O O Z_ w V C N Q N �' N a N C �2Q:- �cv� so c uw `ov � 0: J O N O O l0 O t.. , O¢ 2U t6 � a' V lLo �'" U„_T, C NwL l0 �U C E N Z O "' T E y' .0. m -2 (O N y N .D O C aw �Eo--ca ao oa o U OW20 o o o oU ° o c cc'c 3 � m w UwD� c m� w2V mO N� 2 Z p_ O y g� N$ p L E c N RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ui 1-0 CV z MO W 0- Q W 0 Q z 0 LuLu z Luad W H w N W o 0 N Lu X T W O i is 0 0 0 z PROJECT NO. 180000 DESIGNED BY TL DRAWN BY TL & RIM CHECKED BY TL SHEET NO. PRINT DATE 4/11/2020 7:03:10 PM ELEVATION KEYNOTES KEY VALUE KEYNOTE TEXT 39 40+ YEAR PRESIDENTIAL RANDOM CUT ARCHITECTURAL COMPOSITION ROOFING 40 STANDING SEAM METAL ROOFING. COLOR AND STYLE PER OWNER SPECIFICATIONS 41 CONTINUOUS ALUMINUM GUTTER ON 5/4x6 FASCIA 42 BOARD AND BATTON: lx3 BATTONS @ 16" O.C. ON HARDI-BOARD OR EQUIV. SMOOTH FACED BOARDS 45 FASCIA: 1x4 ON 5/4xl0 (TYPICAL AT GABLE ENDS) 48 6" EXPOSURE HORIZONTAL BEVEL CEMENT BOARD SIDING WHERE INDICATED 55 5/48 CEDAR OR WHITE WOOD TRIM PER BUILDER SPECIFICATIONS. 59 5/44 CORNER TRIM 61 2x10 BELLY BAND w/ METAL FLASHING 67 WINDOW WRAP: 5/46 SIDE RAILS w/ 2x8 TOP RAIL AND 20 DRIP SILL OVER 5/48 TRIM. PROVIDE HEAD FLASHING OVER ALL WINDOWS NOT UNDER EAVES AND/OR EXPOSED TO WEATHER. 71 BOX FRAME POST BASE AND WHITE WOOD TRIMS o/ STRUCTURAL POST PER PLAN 72 STONE OR BRICK VENEER WHERE INDICATED 80 TEMP. GLASS STORE DOOR 81 TEMP. GLASS SLIDING PATIO DOOR. 83 PROVIDE 6" MINIMUM EARTH/WOOD CONTACT 84 TEMP. GL. 85 LOCKING DEADBOLD AT ENTRY DOOR 86 CONCRETE LANDING AND STEPS PER I.R.C./I.B.C. 87 INSULATED STEEL OVERHEAD GARAGE DOOR. MAKE AND STYLE PER BUILDER/OWNER SPECIFICATIONS. OF RIDGE 293' - 8 1) 2ND FLO � 288' - 11 11 �2ND FLO v 280'-97) jk IVIHIIV rLl 279'-71) jkj MAIN FL( M- J 270' - 6" KA Y H nirnht `T`OP OF RIDGE- = 293' - 8 1/4"' jk-ZND FLOOR PLATE _ 288' - 11 " 39 2ND FLOOR 280' - 9 7/8" MAIN FLOOR PLATE,- 279' - 7 1 /8" 'C 41 F'EK 51 RIJU I RUA PLANS WEST ELEVATION 1/4" = 1'-0" 00 M N Now" I 72 ul 71 MAIN FLOOR 270' - 6" 11 - IF - - - - IL I I EIR, U-1 F -9 H W �F=- 83 72 EAST ELEVATION PERSPECTIVE !d� SOUTHEAST�PE RSPECTIVE 1 —F U z 00 0 00 00 z QQ E Q > U IL 2 a- wa y O V CoGO z Co C.� W o uu m —i o W a 2 H E O U ' C f �.: 7 _ q J Q1 L i SW. N A — Z_ N a J C O U1 H N C 0_ m U f6 O :_ .L.• C T U i y C 0 p J y CO O C N N Oa .O 2 (6 .t.. wzo <�- U „_T, C Nw L l0 �U C E N Z p .y T N (0 N N' m N O C Ow Lj2 -. �oc°cmyU U w �� c m� w� V m O N� o zo.ow`�m d$EpH=Eco w RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ui 1-O CV z O Co 0- Q W Q z W 0 W z cn W _ Lu w W o V) J Z N p N LJJ X T W o i 0 0 6 z PROJECT NO. 180000 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 4/11/2020 7:03:31 PM WINDOW SCHEDULE - MAIN FLOOR SYM. NO. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE F COMMENTS MAIN FLOOR 1 3'- 0" 5' - 6" 17 SF SINGLE HUNG 0.30 2 3'- 0" 6' - 0" 18 SF SINGLE HUNG 0.30 TEMP. GLASS 3 3'- 0" 6' - 0" 18 SF SINGLE HUNG 0.30 TEMP. GLASS 4 6' - 0" 5' - 0" 30 SF SLIDER 0.30 TEMP. GLASS 5 5'- 0" 6-0" 25 SF SLIDER 0.30 TEMP. GLASS 6 2' - 6" 5' - 6" 14 SF SINGLE HUNG 0.30 7 2' - 0" 2' - 6" 5 SF PICTURE (FIXED) 0.30 8 7' - 0" 6' - 0" 42 SF DOUBLE SLIDER 0.30 9 3' - 0" 5' - 6" 17 SF SINGLE HUNG 0.30 10 5' - 0" 4' - 6" 23 SF SLIDER 0.30 11 2' - 0" 2'- 6" 5 SF PICTURE (FIXED) 0.30 12 2' - 0" 2'- 6" 5 SF PICTURE (FIXED) 0.30 13 2'- 0" 2'-6" 5 SF PICTURE (FIXED) 0.30 14 2'- 6" 4' - 6" 11 SF SINGLE HUNG 0.30 15 2'- 6" 5' - 6" 14 SF SINGLE HUNG 0.30 16 2'- 6" 5' - 6" 14 SF SINGLE HUNG 0.30 17 2'- 6" 5' - 6" 14 SF SINGLE HUNG 0.30 18 3'- 0" 5' - 0" 15 SF PICTURE (FIXED) 0.30 19 2' - 0" 2' - 6" 5 SF PICTURE (FIXED) 0.30 20 7' - 0" 6' - 0" 42 SF DOUBLE SLIDER 0.30 21 2' - 0" 2' - 6" 5 SF PICTURE (FIXED) 0.30 22 2' - 0" 2'-6" 5 SF PICTURE (FIXED) 0.30 23 2' - 0" 12'-6" 5 SF PICTURE (FIXED) 0.30 24 4'- 0" 3' - 0" 12 SF PICTURE (FIXED) 0.30 25 4'- 0" 3' - 0" 12 SF PICTURE (FIXED) 0.30 26 4'- 0" 3' - 0" 12 SF PICTURE (FIXED) 0.30 27 3'- 0" 6' - 0" 18 SF SINGLE HUNG 0.30 28 3'- 0" 6' - 0" 18 SF SINGLE HUNG 0.30 29 13'- 0" 6' - 0" 18 SF SINGLE HUNG 0.30 30 IT - 0" 6' - 0" 18 SF SINGLE HUNG 0.30 MAIN FLOOR PLATE 31 4' - 0" 4'-0" 16 SF SKYLIGHT 0.50 TEMP. GLASS 32 4' - 0" 4'-0" 16 SF SKYLIGHT 0.50 TEMP. GLASS 33 4' - 0" 4'- 0" 16 SF SKYLIGHT 0.50 TEMP. GLASS 34 4' - 0" 14'- 0" 16 SF SKYLIGHT 0.50 TEMP. GLASS 35 4' - 0" 14'-0" 116 SF I SKYLIGHT 0.50 TEMP. GLASS 36 4' - 0" 14'-0" 116 SF I SKYLIGHT 0.50 TEMP. GLASS Grand total 556 SF DOOR SCHEDULE - MAIN FLOOR SYM. NO. WIDTH HEIGHT DOOR TYPE COMMENTS MAIN FLOOR D1 5'- 0" 8' - 0" DOUBLE PANEL D2 2'-8" 8' - 0" SINGLE PANEL D3 2'-8" 8' - 0" SINGLE PANEL D4 2'-6" 8' - 0" SINGLE PANEL D5 5' - 0" 8' - 0" DOUBLE PANEL D6 T - 0" 8'-0" ENTRY DOOR w/ SIDELITES (TEMP.) TEMP. GLASS (U=0.30) D7 5.-0.. 8'-0" DOUBLE GLASS (TEMP.) TEMP. GLASS (U=0.30) D8 4'- 0" 8' - 0" DOUBLE PANEL D9 2'-8" 8' - 0" SINGLE PANEL D10 16'- 0" 8'- 0" OVERHEAD GARAGE DOOR INSULATED STEEL OVERHEAD DOOR D11 9' - 0" 8'- 0" OVERHEAD GARAGE DOOR INSULATED STEEL OVERHEAD DOOR D12 2' - 8" 8'- 0" SINGLE PANEL D13 2'-8" 8'-0" SINGLE POCKET D14 16' - 0" 8'-0" Door _4-Panel_Stacking_Patio Door D15 8'-0" 8'-0" SLIDING GLASS PATIO (TEMP.) TEMP. GLASS (U=0.30) D16 6-0" 8'-0" DOUBLE GLASS (TEMP.) TEMP. GLASS (U=0.30) D17 2' - 6" 8' - 0" SINGLE PANEL D18 5' - 0" 8' - 0" DOUBLE PANEL D19 T - 0" 8' - 0" SINGLE ENTRY D20 2' - 8" 8' - 0" SINGLE PANEL 1 3/8" SOLID CORE WITH SELF CLOSING MECH. KEYNOTE SCHELDULE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 05 CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 09 DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. FUEL FIRED APPLIANCES: WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU. FT. PER 13 1000 BTU/H THEN NO VENTILATION IS REQUIRED. IF LESS, PROVIDE VENTILATION IN ACCORDANCE WITH G2407.5. 14 ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 23 FIBERGLASS SHOWER PAN OR EQUIV. w/ TILE SURROUND AND TEMP. GLASS SHOWER DOOR. 25 PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. 13 10 E 7 lei k. n A B C D E F G H I J K L M 83' - 8" 12'-4" 16'-6" 1 20'-71/2" 18'-1" 11'-11/2" 5'-0" T-83/4" 4'-10" 4'-10" 8'-01/2" oe 5'-0" T-7" 7'-6" 5'-41/4" 1 5 3/4" V 3'- 3" V V 3'- 3' L2' - 0 1/4"� q8 Cl) - 09 o 0 1T-2" - 2 1sEll u') N co o 6 , io 19 D.1 6 A7,Al SUN PORCH _ O Sim D15 19 BREAKFAST 02 �A2, OUTDOOR PATI 09 C) CD CD VT 19'-7 1 /2= CV 4'-11/2" 20 TEMP.GL. 5'-10" 5'-0" 4'-4" 2'-0" M 20 19 20 III L 2'- 0" - - - - - - - - - - - - �� in - = 11 -1 1/2 BENCH SEAT 2X6 INSULATED / o _ WALL - _ � � co SOAKING TUB SOAP R OWNER SPECS. 09 o o cr) 19 ROLL IN N pi GREAT ROOM 80CFM _SHOWE��° °' MAS ERSUITE ` TEMP. GL. V.T.O. -----------------------� ---- CABINETS PER 20 28 36" HALF WALL -- GAS FIREPLACE FREEZER OWN R SPECS. w/ TEMP. GLASS 4' - 0" 1'- 0" 2 - - - ABOVE. 2'- 51/2"-- KI CHEN 22 2 �I A8 2' 2" 4'-9" 3'-2" 6'-71/2" 6'-3" 04 N 00 v A8 _' ® 2X61NSUL. WALL 01 g„ PANTRY 2' 0" LO T-81/2" 9'-2" 11 MA TER BATH p$ BARN STYLE 0 o DOOR - C? 21 a> LINEN CAB. S.D. , N - - 4 -M OPTIONAL PREP SINK 3'- 1/4" P �RI-------0_g- --- ------------- -- VI D 13 12'- 7 3/4" 5'- 6 1 /4" 1 lo 7 0 1/4" 1' - 7 1 /4" ® ® 5'-6" it i 1 T-51/2" _ � '-I ® 1 06 0' - 9" o " s O O 1 WHOLE HOUSE O 3 -3 O N pg OEt L - C.O. S.D. - - TIMER CONTROL 23 -- - -- - -- _ _ --- --_-----------= D 8 UNI B- H 2'-4„ v T ----------- --- - - - - - 18 Sim N D1 4' - 0" ii a ii q 2 23 ' ----�--- v D2 N \ / UP o N O I I NOTE: ACCESS ATTIC u LOCATIONS MAY X� �ACCESS° 41 07 Sim r 180 CFM WHOLE HOUSE u HANDRAIL RYER _ 2 FAN w/ TIMER (V.T.O.) VARY PER OWNER co D S.D. ■ 80CFM A6 07 INTERCONNECTED TO SPECIFICATIONS `--- 14 J iv 10 - UPSTAIRS BATH FAN. 1 PROVIDED THEY LANDING: _ O UP I 1 qg MEET REQUIREMENTS ' OF I.R.C. - I JOISTS 16 O.C. � CUBBIES AND 1' - 8" A9 D5 ASHER BENCH PER OWNER - -- --- 1 CRA L SPECIFICATIONS. _ AccE s DINING RM. OFFICE ( M L-------------------- _ ENTRY 0' 9" N LAUNDRY/ J M M CD LIB RY - - _ _ UD RM. o _ --- 08 9 o O7 19 zn 20 - z¢ 25 co 20 J - LOW STORAGE UNDER ih 08 i� _______= I ® STAIRS. D20 I I I L-------- 5' I COVERED PORCH _6 3'-35/8" F- ---- 2 6 4'-47/8" 5 -6 -- °' A7 (CONCRETE PATIO) 1� 9 1/2" 03 01 02 12 13 03 A9 3 1/2" Of 6'- 10 1/2" 3' - 9" 14'- 5 1/2" loo 7 I GAS FURNACE: AFUE 94% OR BETTER, 25 1 OPTION 3a, 1.0 CREDITS. A7 A8 1 TANKLESS GAS WATER 0'-9" I SYSTEM: EF 0.91 OR BETTER, 4'-61/2" 3'-0" 12'-81/2" 10'-61/2" 12'-81/2" 3'-91/2" I OPTION 5c, 1.5 CREDITS. _ USE NAVIAN RW240 OR EQUIV. 4'-6" 11'-0" 14'-0" 9'-6" 17'-0" = I 24 0 3 PAR GARAGE I D10 5/8" TYPE "X" GWB AT CEILING UNDER HABITABLE SPACE ABOVE iv o `o M 3 3 Co LO A9 26 A9 I I I I I I I I INV ------------ 0 L? I � � I 4 D11 4 A9 ' A9 I I (V I 2 L 18 CONCRETE v ' Cl) LANDING AT 01 DOOR 12 11 13 04 2'-111/2" 5' -6" 2' -6" 2'-6" 5'-51/2" 16'-0" 4'-61/2" MAIN FLOOR 1 1 /4" = 1'-0" U z 00 0 00 00 z QQ E Q U IL w a •y 0 V fM GO �O z 00N C W 0 uu m -i 0 Lua H E O " U N C C V C O O N y 3 J t' Z_w�cwp oT! mock cma N a J C 0 U1 H O p d U E a N C amoum :_� cTo� yco �0y�vw�`i cow 0`000:= p J Oa y CO O Q C N t` 0 O N Eo N O lL¢ �- UT, NwLl0 a'p C C E N ZO ..mma�'� oc Eocc��3�Nyo OWgUoo.�OV U w �� c m� y\ L)m O y v o zo.owm .2 po RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ui u 1-0 CV z 0 00 0- Q W � z 0 LuLu z Lu W H u LLu W o C) J Z N 0 N LJJ X 3rm W 0 w 0 c 0 M 0 z PROJECT NO. 180000 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL L SHEET NO. A5 PRINT DATE 4/11/2020 7:03:46 PM WINDOW SCHEDULE - 2ND FLOOR SYM. NO. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE COMMENTS 2ND FLOOR 37 2'- 6" 4' - 0" 10 SF CASEMENT - SINGLE 0.30 38 3'- 0" 2'- 0" 6 SF PICTURE (FIXED) 0.30 39 3'- 0" 2'- 0" 6 SF CASEMENT - SINGLE 0.30 40 4' - 0" 3'- 6" 14 SF PICTURE (FIXED) 0.30 41 T - 0" 3' - 6" 11 SF PICTURE (FIXED) 0.30 42 T - 0" 3' - 6" 11 SF PICTURE (FIXED) 0.30 43 2'- 0" 2' - 0" 4 SF PICTURE (FIXED) 0.30 45 2'- 6" 4' - 0" 10 SF CASEMENT - SINGLE 0.30 46 2'- 6" 4' - 0" 10 SF CASEMENT - SINGLE 0.30 47 2'- 6" 4' - 0" 10 SF CASEMENT - SINGLE 0.30 48 2'- 6" 4' - 6" 11 SF SINGLE HUNG 0.30 49 2'- 6" 4' - 6" 11 SF SINGLE HUNG 0.30 50 2'- 6" 3'- 9" 9 SF CASEMENT - SINGLE 0.30 EGREES WINDOW w/ FULL 90 DEG. SWING 51 2'- 6" 3'- 9" 9 SF CASEMENT - SINGLE 0.30 EGREES WINDOW w/ FULL 90 DEG. SWING 52 2'- 6" 3'- 9" 9 SF CASEMENT - SINGLE 0.30 EGREES WINDOW w/ FULL 90 DEG. SWING 53 2'-6" 3' - 9" 9 SF CASEMENT - SINGLE 0.30 EGREES WINDOW w/ FULL 90 DEG. SWING 54 T - 0" 2' - 0" 6 SF PICTURE (FIXED) 0.30 55 2'- 6" 3'- 0" 8 SF PICTURE (FIXED) 0.30 56 2' - 6" 3' - 0" 8 SF PICTURE (FIXED) 0.30 57 2' - 6" 3' - 0" 8 SF PICTURE (FIXED) 0.30 58 2' - 6" 3' - 0" 8 SF PICTURE (FIXED) 0.30 Grand total 187 SF DOOR SCHEDULE - 2ND FLOOR SYM. NO. 2ND FLOOR D21 WIDTH 3' - 0" HEIGHT DOOR TYPE COMMENTS 6' - 8" SINGLE PANEL D22 2' - 6" 6' - 8" SINGLE PANEL D23 3' - 0" 6' - 8" SINGLE PANEL D24 2' - 6" 6' - 8" SINGLE PANEL D25 2' - 6" 6'- 8" SINGLE PANEL D26 2' - 6" 6'- 8" SINGLE PANEL D27 2' - 6" 6' - 8" SINGLE PANEL D28 6' - 0" 6'-8" BI-PASS CLOSET DOOR D29 2' - 8" 6' - 8" SINGLE PANEL D30 2' - 6" 6' - 8" SINGLE PANEL D31 2' - 6" 6' - 8" SINGLE PANEL KEYNOTE SCHELDULE KEY VALUE TEXT 01 GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING DEVICE. (R302.5.1) 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 03 GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 05 CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) 07 STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM (311.7.6) 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 09 DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. LISTED. (M1303/ G2427.2.1) 10 DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 12 PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. 13 FUEL FIRED APPLIANCES: WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU. FT. PER 1000 BTU/H THEN NO VENTILATION IS REQUIRED. IF LESS, PROVIDE VENTILATION IN ACCORDANCE WITH G2407.5. 14 ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. 18 CLOSET SHELVING AND DRAWER ORGANIZERS PER BUILDER SPECS. 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 23 FIBERGLASS SHOWER PAN OR EQUIV. w/ TILE SURROUND AND TEMP. GLASS SHOWER DOOR. 25 PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. 28 HYDROBLOK OR EQUIV. SHOWER PAN w/ TILE SURROUND. 0 0 0 w Z_ W CD 141 75. N co z O HANDRAIL, GUARD AND BALUSTERS TO CONFORM TO I.R.C. OP�.,,. SUCH TF w c� co r- 10" MIN. TREAD RESIDENTIAL STAIRS TO BE - 1 1/4" DIA. MIN; 2" DIA. MAX. HANDRAIL w/ RETURNS TO WALL. DBL. JOIST (U.N.O.IN FIRE BLOCK BETWEEN 3/4" MIN; STUD 1 1/4" MAX. BAYS AT WALLS IN NOSING 1/2" MIN. PLYWOOD RESIDENTIAL STAIR - IRC. 3/4" = 1'-0" SIMPSON LUS210 JOIST - SIMPSON A35 EACH SIDE OF -- (1) LAYER 1/2" GWB 2x12 STRINGERS 2ND FLOOR U z 00 00 0 00 z QE Q o IL Y 2 Lm waT C O C V ��@) fM GO 2 z 00N C W �2 za 0 Lu m J 0 W a 2 E O U C + .y c O O Z_ EO. N a J C O N H O p j 0.0E a 2 C 0_m U N:+� O .. N C O C TU.22 � O J Q N� CO O Q C 01 �@ O� N_ 05 .L-� "�=2cNOL'='mUSEN OWgUoo..oUEoc C3 y" UJJH c-' �-`OU a$ mO yv `o w Omcmiad-o Emy?t»` E@ d Z 6 0 y N .2 p F RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ui 1-0 CV O 00 z 0- Q W Q z Lu0 W z Lu W _ Lu W Lu V) J Z N 0 N LJJ X 3rm W o o 0 0 N N o �n aa) E E U �U N CL a� O Z PROJECT NO. 180000 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A6 PRINT DATE 12/1/2020 8:48:03 AM 1" AIR SPACE RIPPED BLOCKS w/ (3) 2" dia. HOLES OR (3) 1" "V" NOTCH w/ WIRE SCREEN BETWEEN EACH RAFTER )VERHAN( PER PLAN EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER STRUCTURALPLANS. R-21 BATT INSULATION AT RIM 2x6 BASE PLATE ANCHOR BOLTS PER STRUCTURAL. 4" TIGHTLINE DRAIN WHERE REQ'D 16'-0" 2ND FI MAIN F ROOFING PER ELEVATIONS o/ 30 # FELT OVER %6"APA RATED 24/16 SHEATHING R-38 BATT INSUL. RAFTERS PER ROOF PLAN 2" CEILING GWB TOP PLATES & TRUSS TIE PER STRUCTURAL CAULKING/ SEALANT BEAD AT FLOOR PERIMETER SUB FLOORING & FLOOR JOISTS PER STRUCTURAL FLOOR TRUSSES PER PLAN Y2" GYPSUM CEILING BOARD TOP PLATES & TRUSS TIE PER STRUCTURAL Y" GYPSUM WALL BOARD w/APPROVED P.V.A. VAPOR RETARDER R-21 BATT INSULATION 3/4" T&G PLY OR EQUIV. SUB -FLOOR GLUED & NAILED TO FLOOR JOISTS. SEE TYP. ASSEMBLY R-30 BATT INSULATION i n R-30 BATT INSULATION �I P.T. 2x10 MUD SILL RIPPED TO 8" FOUNDATION WALL SIZE AND w/ ANCHOR BOLTS PER REINFORCING PER PLAN SHEAR WALL SCHEDULE. 4" PERF. FT'G DRAIN. HANGER PER SCHEDULE WRAP IN FILTER FABRIC w/ GRAVEL OVER. dii FOOTING SIZE AND REINFORCING - PER PLAN. Z o o a w� °e �iA TYPICAL TWO STORY ASSEMBLY SCALE: 3/4" = 1'-0" 4 a III I II I II o. 0e 08 K 4" CONIC SLAB o/ COMPACTED GRANULAR FILL I I �I �Z a w <a. a 9 10 11 12 13 16-3" 1 12'-0" 6\BUILDING SECTION �T SCALE: 1/4" = 1'-0" P.T. 2x6 MUD SILL w/ ANCHOR BOLTS PER SHEAR WALL SCHEDULE. FOUNDATION WALL SIZE AND REINFORCING PER PLAN FOOTING SIZE AND REINFORCING PER PLAN. PER PLAN RECESSED JOISTS @ GARAGE SCALE: 3/4" = V-0" TOP OF RIDGE PLATE FLOOR PLATE MAIN FLOOR 1" AIR SPACE w/ CARDBOARD BAFFLE. EXTEND 24" ABOVE INSULATION VENT BLOCKS w/ (3) 2" dia. WIRE SCREENED VENT HOLES @ EA. BLOCK CONT. ALUM .GUTTER ON FASCIA BOARD I PER ELEVATIONS ROOFING PER ELEVATIONS o/ 30# FELT o/ SHEATHING PER STRUCTURAL o/ MANUF. TRUSSES PER PLAN R-49 BATT OR BLOWN INSUL. I��� \ \2" GYPSUM CEILING BOARD IYn�I OVERHANG \TOP PLATES &TRUSS TIE PER PER PLAN STRUCTURAL D__ %" GYPSUM WALL BOARD w/APPROVED P.V.A. VAPOR RETARDER EXTERIOR FINISH PER ELEVATION o/ 15# BUILDING PAPER OR R-21 BATT INSULATION APPROVED AIR INFILTRATION BARRIER o/ SHEATHING PER NOTE: STRUCTURAL PLANS. FOR ROOF TO BEAM ASSEMBLY BEAM REPLACES TYP. WALL ASSEMBLY 1 TYPICAL ROOF ASSEMBLY bo &TOPOIF RIDGE 2ND FLOOR PLATE 2ND FLOOR_ MAIN FLOOR PLATE . N FLOOR CEILING FRAMING PER PLAN SIDING INSTALLED PER MANUF. SPECIFICATION EXTERIOR TRIM PER PLAN 4"x_ "L" METAL FLASHING w/ DRIP EDGE INSTALLED UNDER BARRIER 4 5 6 5-0" 21'-3" 8 BUILDING SECTION A7 SCALE: 1/4"=, o DBL. 2x6 TOP PLATES 2" RIGID R-10 INSULATION INSTALLED IN CAVITY BETWEEN HEADER & INTERIOR G.W.B. HEADER PER PLAN SEALANT I WINDOW FINISH AND TRIMS I PER OWNER SPECS. I HEADER INSULATION DETAIL SCALE: 1 1/2" = V-0" J 0 0 0 Of 0 Q w z ED 1%" dia. MIN., 2" dia. MAX. HANDRAIL w/ RETURNS TO WALLS Erg x Y" MIN. PLWD RISERS Q w %4' PLWD OR co M 0 BETTER AT TREADS z Z 10" MIN. g m RUN MIN• o Q 1"'IMAA Q v Co 8^' 9 10 11 12 16'-3" 12'4" NOTE: MIN. T-0" CLEARANCE WIDTH REQUIRED FOR STAIRS INTERIOR STAIRS SCALE: 3/4" = V-0" �7 BUILDING SECTION AT SCALE: 1 /4" = 1'-0" BALUSTER TO CONFORM TO IRC w/ SPACING SUCH THAT A 4" SPHERE SHALL NOT PASS THROUGH Y4' T&G APA 48/24 RATED SHEATHING GLUED & NAILED TO FLOOR JOISTS DBL. JOIST U.NO. ON PLANS JOISTS PER PLAN Q�HANGER PER SCHEDULE SIMPSON "A35" EA. SIDE AT STRINGERS STRINGERS PER PLANS (1) LAYERY2" GWB UNDER STRINGERS `FIRE BLOCKING BETWEEN STUD BAYS AT WALLS IN CONTACT w/ STRINGER. 13 U z � N Ip Ib Q U C 2 .o� W d Lu O V 0 � Iu J � � z o .S N Lu w E W OX 0 J 0 W a H E O V C U O N N t m y c J t m m a 2-so 03,6a z U E a c U6 cT�.--yco - U w O C7 O m 0 a w O Y C N C a w Oo0 OLLI UO-U �dU cm .o cw J aU m a ac omO wOam8 E ? aEim�o�E�a� RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z W W Z W W ~ Q W N mmi in Z V; I� mmj O z 0 W Q W IJ Lij m m 0 c 0 T 0 0 Z PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A7 PRINT DATE 11/11/2019 5:43:17 AM 4 5 6 5'-0" TOP_ OF RIDGE FLOOR PLAT 2ND FLOOR PLA bo 2l'-3" Q 8 00 9 10 11 12 28'-3" 1 BUILDING SECTION A8 SCALE: ,,a,,.o 13 2 BUILDING SECTION pg SCALE: 1,411-011 0 z � N W W Q � U C CL Y= rn w dFn W � � c O U�� - V V ��0 (M O z O O C O N W �!! .0 lx O E W Co J 0 W a H E O u + o l iii r�' C JLF 1 U c Z N 6C d y C R U C O T N lN c O L N— T T C N 3 a) _' f6 U a g y c 0 O 65 N C Nam o R °ram,~ 0 c T�L°.0 E aai c 2 �H0o-m`-' iU UUeo wZ Oaofwa-�d�rn� Ea).._odo,oW3L. oae2y�cOwU0E Cu o OUJ 4yo5' o LLI ZoH wCa64)lc�n RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z LU 0 �I W w z W W � 1- Q L U N mmj Z Z V; oz mmj O 0 W :�i = in W 0 cu 0 0 Mn a� 0 z PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A8 PRINT DATE 11/11/2019 5:43:17 AM Eo TOP OF ID FLO Co TOP OF RIDGE &1 2ND - KIM I J K L 26-0" 3 BUILDING ' SCALE: 1 /4" = 1'-0" A 9, SECTION 1 BUILDING SECTION A9 SCALE: 1,4-Vo 0o TOP OF RIC 2ND F 2ND F MAIN 91 TOP OF RIDGE ■ 12ND FLOOR PLA- 2ND FLOOR PLF 5 a I 4 BUILDING A 9 SCALE: 1 /4" = 1'-0" SECTION '2 BUILDING SECTION A9. SCALE: 1/4" = 1'-0" 0 z - N W W Q � U C CL Y= rn w dFn W � � c O (.5 - V V ��0 (M O z O O C O N - W �!! .0 lx O E W Co J 0 W a H E O u C t � I, U c O 16'T T r c N 3 N =' D E U a y c 0 Z_ p U O a5 N C Oa Nam o R °ram,~ c U E ai c HO ci@U,r�`0t yo 2 0. me o o c- o _ U OUwv ``_'^-�'mcywo 2`m0�Eo, �ZOa�ya� �mv,d m�W.D Oc awe : E a) y._ o ama o u a= 0 o O w 2 U° p w o U 0 2 0. = O s o I. 0Jfp: M80 aa' m05a 2 LLJ Zo-owl. dd_o�Ecd RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z LU W w z W W � 1- Q L U N Z V; Q O zO W :�i = o W 0 cu 0 0 Mn a� 0 z LLL PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A9 PRINT DATE 11/11/2019 5:43:17 AM GENERAL NOTES All design and construction shall conform to the requirements of the International Building Code 2015 Edition. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or construction for all the following: Structural steel, steel canopies, glued -laminated members and pre -manufactured wood members. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. DESIGN LOADS LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 7 L = 40 PSF (Residential) SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Factors: Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7-10 Ch. 28 (Envelope Procedure) with the following factors: Exposure Category = B Iw = 1.0 Velocity (3 sec) =110 mph (ult) Kzt = 1.0 Design wind pressured for determining forces on components and cladding are determined in accordance with ASCE 7-10 Chapter 30. SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section 12.8 with the following factors: Risk Category = II Ss = 1.30 Site Class = D S1 = 0.500 Design Category = D SDS = 0.867 R = 6.5 (wood shear wall) SD1 = 0.500 Ie = 1.0 Cs = 0.133 (ult.) FOUNDATIONS Concrete foundations shall bear on stiff, competent, undisturbed native soil. Prior to construction, the contractor shall obtain confirmation from the Building Official that the native soil at this project is adequate to support the following bearing pressure: Allowable bearing pressure used for structural design = 2000 psf (assumed) Where footings must bear on structural fill due to inadequate soil conditions, the fill shall be mixed and compacted in accordance with specifications provided by a Geotechnical Engineer licensed in the State of Washington. Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the Building Official prior to excavation. CONCRETE Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete for Buildings." CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs but shall conform to ASTM C 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water-soluable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. ANCHORS Use of drilled concrete anchors, including expansion bolts and adhesive anchors, where not specified in these documents shall be subject to approval by the Architect. EXPANSION BOLTS: Expansion bolts in solid concrete shall be wedge -type anchors made of carbon steel. Bolt size, spacing and embedment length shall be as designated in these drawings. Bolts shall be installed per the manufacturer's instructions with inspection per schedule. Expansion bolts shall be Simpson Strong Bolt 2 or approved equal. A current ICBO or ICC Report shall be submitted for alternates. ADHESIVE ANCHORS: Adhesive or epoxy type anchors in solid concrete shall be installed per the manufacturer's instructions. Anchor size, spacing and embedment length shall be as designated in these drawings. Adhesive shall be Simpson AT-XP. A current ICBO or ICC Report shall be submitted for alternates. WOOD SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb(psi) Wall Studs Stud 675 Plates & Planks Hem Fir #2 850 Joists & Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FN intersections Truss to top plate 3" x 0.131" 4 TN *EN = end nail, FN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg 7/16" 32/16 C-D INT APA with Exterior Glue (CDX) Roof Shtg 15/32" 32/16 C-D INT APA with Exterior Glue (CDX) Sub Floor Shtg 3/4" 48/24 T&G C-D INT APA with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Symbol Species Fb E GLB 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLB 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12" member depth): Symbol Fb E PSL 2900 psi 2,000,000 psi LVL 2600 psi 2,000,000 psi LSL 1700 psi 1,300,000 psi Versa -Lam (1%4-2%$") 2800 psi 2,000,000 psi VersalLam (3%" & wider) 3100 psi 2,000,000 psi PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer licensed in the State of Washington, who is regularly engaged in the design of plate -connected wood trusses. Truss design shall be accordance with IBC Section 2303.4. Trusses shall be design for the following dead loads: top chord bottom chord total roof trusses 13 psf 5 psf 18 psf In addition to dead loads, the design shall include the live, wind, snow and snow drift loads as identified in the "Design Loads" section of these drawings. In addition, the truss design shall include concentrated and axial loads shown on framing plans and hanger schedules in these drawings. Roof trusses shall be designed for wind net uplift of 10 psf unless otherwise noted on the drawings. Floor trusses shall be design for maximum live load deflection = 1/2" and minimum live load deflection ratio = L/480. Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall be supplied with tapered hardwood shimming so that every chord bears on the full width of every support, without notching the truss members. The truss manufacturer is responsible for ensuring the bearing seat does not exceed the sill plate capacity of the supporting element. PREMANUFACTURED WOOD I -JOIST: Shall be fabricated by Truss -Joist or Boise Cascade. Alternative manufactures must be approved by the Architect or Engineer. Joists shall be installed according to the manufactures instructions including blocking, web stiffeners, bridging, etc. Fasten joists to supports as recommended by the joist and hanger manufacturer. Provide temporary bracing as recommended by the manufacturer to hold joists in place until permanently secured, Cut openings in joist webs only as allowed by the manufacturer. BUILDING OFFICIAL INSPECTIONS The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: -Footings bear on competent native soil per the "Foundations" section above -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule -Shear wall hold-downs -Verify type, size and grade of structural steel members and bolts TYPICAL DETAILS n addition to the details and schedules on the framing plans, those noted as "Typical" shall be sed throughout the structure as applicable. STRUCTURAL NOTES T RE x a 2 00 a WOOD FRAMING PER PLAN VARIES. SEE 17/S2 FOR ALL CONNECTIONS PT SILL PLATE w/ ANCHOR BOLTS AND WASHERS PER SHEAR WALL SCHEDULE. MINIMUM ANCHOR BOLT EMBEDMENT = 7". #4 HORIZ. AT 18" o.c. AND (2) AT TOP OF WALL #4 VERT. DOWELS AT 18" o.c. ALTERNATE HOOK AT BOTTOM FOOTING PER PLAN SEE 3/S1 FOR ALTERNATE AT HUNG JOISTS TYPICAL CONCRETE FOUNDATION 1 SINGLE REINFORCING NOTES: 1. VERTICAL REINFORCING NOT SHOWN FOR CLARITY 2. SEE STRUCTURAL NOTES FOR CLEAR COVER 24" #4 x 24" MATCH HORIZ REINF. 24" 44 x 24" MATCH HORIZ REINF. #4 x 24" MATCH HORIZ REINF. DOUBLE REINFORCING TYPICAL CONCRETE CORNER REINFORCING 1 4 DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES 10d 6" OC 12" OC 6" OC SUB-FLR HNO 10d & GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED PANEL JOINT �F i.=' .i = 'A -11,:` Y. 11 11 11 1, IJ 1`1 IJ A: 11 BOUNDARY -I 11 11 11 ih W r1 u 11: 11 NAILING IJ 4: 11 11 11 k li 11 IJ 11 IJ TOP PLATE BLOCKED CONTINUOUS :1 9: 11 11 IJ IJ 11 11 "OTHER" PANEL PANEL JOINT EDGE NAILING INTERMEDIATE JOIST/TRUSS NAILING DIAPHRAGM DETAIL TYPICAL DIAPHRAGM NAILING 7 SON CS16 WITH (20) 0 DEL. TOP PLATE D AT EACH SIDE. JI AS NEEDED. f PER PLAN NOTES: 1. USE THIS DETAIL AT ALL LOCATIONS WHERE BEAM WIDTH EXCEEDS 33/2" AND/OR BEAM BOTTOM BEARING IS BELOW DOUBLE TOP PLATES. 2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6 WALLS, 3-1/2" BEARING ON 2x4 WALLS. TYPICAL PLATE STRAP AT BEAMS 1 1 Q SHEAR WALL PER PLAN PT SILL PLATE w/ ANCHOR BOLTS AND WASHERS PER SHEAR WALL PLAN AND SCHEDULE. EMBED = 7" MIN. x z_ 2� a W PERFORATED FTG. DRAIN CON'T m CONCRETE SLAB ON GRADE PER PLAN. ELEVATION MAY VARY. SEE ARCHITECTURAL FOR INSULATION REQUIREMENTS WHERE APPLICABLE. #4 HORIZ. AT 18" o.c. AND (2) AT TOP OF WALL #4 VERT. DOWELS AT 18" o.c. ALTERNATE HOOK AT BOTTOM -FOOTING PER PLAN TYPICAL CONCRETE FOUNDATION AT SLAB 1 2 LAP JOIST OVER BEARING MIN. 6" AND NAIL WITH (3) 10d FLOOR JOISTS PER PLAN 2x CONT. BLOCKING OVER BEAM VAPOR BARRIER PER ARCHITECTURAL ro TOP PL FLOOR SHEATHING PER STRUCTURAL NOTES INSULATION PER ARCHITECTURAL - 2x PONY WALL WITH STUDS AT 16" o.c. SHEAR WALL AT'SIM' 2x SILL PT SILL PLATE WITH %z" DIA. ANCHOR BOLTS AT 48" o.c. %$" DIA. ANCHOR BOLTS PER SHEAR WALL SCHED. AT'SIM'. FOOTING WITH REINFORCING PER PLAN FINISHED GRADE TYPICAL CRAWL SPACE FRAMING 1 `j NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE $ II II I I ROOF TRUSSES/ I I� RAFTERS BELOW I I I I 2x6 BLOCK BETWEEN ROOF �~ _ TRUSSES BELOW W/ (2) 16d I I EA END I I I I I I i 2x6 PLATE W/ I 1 i (2) 16d INTO EA ROOF I I i TRUSS BELOW I�I� 1 I 14 1 I I I 2x4 RAFTERS Pa 24"o.c. POST DOVI N ITO ROOF / I I TRUSS BELOV� AT 24" O.C. i I I I I I I I I I i I I i II TYPICAL ROOF OVERFRAMING 1 1 SHEAR WALL PER PLAN SOLE PLATE CONNECTION PER SHEAR WALL SCHEDULE EDGE NAILING TO SOLE PLATE SLAB ON GRADE PER PLAN FLOOR BOUNDARY NAILING PER DIAPHRAGM SCHEDULE 2x PT SILL PLATE RIPPED TO MATCH CONC. WALL WIDTH w/ BOLTS PER SHEAR WALL SCHEDULE FLOOR JOISTS PER PLAN, JOIST BLOCKING AT 48" o.c. WHERE JOISTS ARE PARALLEL TO WALL. HANGER PER PLAN PROVIDE VAPOR BARRIER BETWEEN JOIST AND CONCRETE WALL FOUNDATION PER PLAN. SEE DETAIL 1/S1 UNLESS NOTED OTHERWISE RAISED STEM WALL FOUNDATION I $ HOLD-DOWN ANCHOR SCHEDULE HOLD-DOWN ANCHOR IN CONC. STEM WALL ANCHOR IN THICKENED SLAB EPDXY ANCHOR IN EXISTING , z FOUNDATION FLOOR TO FLOOR ANCHOR' HDU4 SB %$ x 24 PAB5 x 6" EMBED %$" DIA. x8" EMBED %$" DIA. HDU5 SB %$ x 24 PAB5 x 6" EMBED %$" DIA. x12" EMBED %$" DIA. HDU8 SB Y/ x 24 PAB7 x 81/z" EMBED %$" DIA. x18" EMBED %" DIA. HDU11 SB 1 x 30 PAB8 x 10" EMBED NA 1" DIA. HDU14 SB 1 x 30 PAB8 x 10" EMBED NA 1" DIA. NOTES: 1. F1554 THREADED ROD 2. EPDXY ANCHORS SHALL ONLY BE USED WHERE INDICATED ON THE FOUNDATION PLAN w 0 co w CRIPPLE STUDS AT 16" O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUDS) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN SHEAR WALL PER PLAN FLOOR BOUNDARY NAILING SHEAR WALL SHEAR CLIPS PONY WALL SHEAR WALL PER 1 ANCHOR TYPE HOLD-DOWN PER 1 SQUASH BLKG MATCH POST SIZI - ANCHOR PER SCHEDULE ADD #4 x 48" AT EACH ANCH HDU ANCHOR SCHEDULE 1 6 SOLID BLKG MATCH WIDTH OF BEAM/GIRDER TYPICAL HEADER DETAIL 1 Q FLOOR SHEATHING PER STRUCTURAL NOTES TYP ALIGN JOIST/BEAM PER PLAN OVER SHEAR WALL BLOCKING EACH END OF SHEAR WALL AND 48" o.c. 2x SILL PT SILL PLATE WITH 5/" DIA. ANCHOR BOLTS PER SHEAR WALL SCHED FOOTING WITH REINFORCING PER PLAN FINISHED GRADE I SECTION 112 Ross Engineering Design Inc JOB # 19088 ryan.ross@rossengineer.com y O= aT,� Ku E T 9 a m o Z i F O 'O UN C >nN C O Z O N UU o"- c o p O O C 9 NaT m�NvniU >.o� S tUEdco 2 0 J O O a' Z Q L y N@ U y m 0 - EO C a W 7]0 (n C C C N 9 O U O O mrn c O omO5t J an mRn E d�1 >d w aa o F E� d J Q O H O 2/14 2020 ��� N ' RD og VfAS,�J p 10 19 8 ,a 46411 `ySfUNAL�'� ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W Z W W Z W W ~ Q H W tn mmi V; 0 O z o W :2 Q 0 WLU m R c O a �L to O t� O Z111111111111 FILE/ NO. 190807 DATE DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: S1 PRINT DATE 12/9/2019 ROOF BOUNDARY NAILING CONT. 2x BLKG WITH VENTING PER ARCHITECTURAL. SEE 8/S2 FOR ALTERNATE AT RAISED TRUSS HEELS. SHEAR WALL EDGE NAILING SHEAR WALL PER PLAN TYP Lo TRUSSES PERPENDICULAR SHEAR WALL SOLE PLATE NAIL/SCREW SHEAR WALL EDGE NAILING FLOOR BOUNDARY NAILING CONT. RIM JOIST SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 13/S2 SHEAR WALL EDGE NAILING SHEAR WALL S( NA SHEAR WALL EDG FLOOR BOUNDAR SHEAR WALL SHI OR ALTERNATE JOISTS PERPENDICULAR JOISTS PERPENDICULAR TYPICAL SHEAR WALL SCHEDULE NUMBER OF SHEAR WALL STUD/BLKG. SILL PLATE / SOLE PLATE FRAMING ANCHOR TO NAIL/SCREW SHEATHED EDGE 3 AT ADJOINING $ 9 SYMBOL SHEATHING SIDES NAILING PANEL EDGES s SIZE CONCRETE ' TO RIM JOIST SHEAR CLIPS SWl(P) 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 3"x.131" NAIL 3"x.131" TOENAIL 9 @ 48" OC @ 6" OC @ 6" OC SW2(P) 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 24" OC SEE @ 48' OC @ 6' OC SW3(P) STRUCT 1 8d @ 4" OC 2x 2x 5/8' DIA. AB 16d BOX NAIL LTP4 @ 18" OC NOTES @ 32" OC @ 4' OC SW4(P) 1 8d @ 3" OC 4 3x e 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 14" OC @ 24" OC @ 3' OC SW5(P) 1 8d @ 2" OC4 3x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 10" OC @ 18" OC @ 2.5" OC SW6(P) 2 8d @ 3" OC4 3x 3x 5/8" DIA. AB SDS25600 LTP4 @ 14" Oc @ 18" OC @ 5" D.C. EA. FACE sox SHEAR CLIPS PER SHEAR WALL SCHEDULE WHERE APPLICABLE TYP. SQUASH BLOCKS IN RIM JOISTS AT ALL POSTS AND HOLD-DOWNS, ALL LEVELS. SEE TYPICAL POST BLKG. DETAIL TYP. ANCHOR TYPE HOLD-DOWN W/ ANCHOR ROD PER HOLD-DOWN SCHEDULE TYP. 8d AT 12" ox. NAILING AT ALL SHEAR WALL SCHEDULE NOTES INTERMEDIATE SUPPORTS 1. SHEAR WALLS NOTED AS "SW " INDICATE "SEGMENTAL SHEAR WALL" PER DETAIL (RIGHT) 2. SHEAR WALLS NOTED AS "SW_P" INDICATE "PERFORATED SHEAR WALL" PER DETAIL (RIGHT). APPLY ALL SHEATHING, NAILING AND FRAMING REQUIREMENTS PANEL EDGE NAILING TYP. PER SCHEDULE TO THE FULL LENGTH OF SHEAR WALL INCLUDING AREAS ABOVE AND BELOW OPENINGS. 3. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE. SILL/SOLE PLATE W/ 4. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS 1z". ANCHORS PER SCHED. TYP. 5. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL HORIZONTAL ADJOINING PANEL EDGES. 6. AT SW4 ONLY, 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 3"0.131" NAILS @ 3" ox EACH FACE. ANCHOR TYPE HOLD-DOWN 7. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"x3"x.223" STEEL PLATE WASHERS. LOCATE EDGE OF WASHER PER PLAN WHERE APPLICABLE. WITHIN %" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE DIAGONALLY SLOTTED 1.75" MAX. SEE SCHEDULE FOR ANCHOR 8. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING. ROD TYP. 9. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS. 10. SEE DETAIL (TOP FAR RIGHT) FOR TYPICAL TOENAIL 11. SEE DETAIL (BOTTOM FAR RIGHT) FOR BLOCKING AND SHEAR CLIP REQUIREMENTS AT DOUBLE SIDED SHEAR WALL 1 SIMPSON RBC ROOF BOUNDARY NAILING AT 48 ox. ROOF SHEATHING PER STRUCTURAL NOTES SHEAR WALL EDGE NAILING 5��< EXTEND SHEARWALL SHTG OVER GABLE - END TRUSS TO ROOF DIAPHRAGM SHEAR WALL EDGE NAILING SHEAR WALL SHEAR CLIPS (BOTTOM CHORD TO TOP ROOF TRUSSES PER PLAN PLATE) H1 CLIP EACH TRUSS 2x6 STUDS AT 16" ox. SHEAR WALL EDGE NAILING TYP — TRUSSES PARALLEL SHEAR WALL SOLE PLATE FLOOR SHEATHING PER NAIL/SCREW STRUCTURAL NOTES TYP SHEAR WALL EDGE NAILING FLOOR BOUNDARY NAILING SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 10/S3 FLOOR JOISTS PER PLAN SHEAR WALL EDGE NAILING PRESSURE TREATED SILL PLATE PER SHEARWALL SCHEDULE. BOLT EMBED = 7" MIN. FLOOR JOISTS PER PLAN FOUNDATION PER PLAN _ ROOF SHEATHING PER STRUCTURAL NOTES ROOF BOUNDARY NAILING TYP ROOF TRUSS 2x BLBY KING PANELS PROVIDED TRUSS MANUFACTURER TRUSS AND GABLE WALL BRACING PER TRUSS MANUFACTURER SHEAR WALL SHEAR CLIPS --ZI 1 2x6 STUDS AT 16" ox. TYP SHEAR WALL EDGE NAILING SHEAR WALL TO ROOF TRUSS 1 7 JOISTS PARALLEL SHEAR WALL PER PLAN SHEAR WALL � STyO SW_P UX SW_ YO�x N� HOLD-DOWN ID HOLD-DOWN ID SHEAR WALL KEY -A— SHEAR WALL KEY Il——II---iT-----IT--IT--7 a 1.1 LI I I 1.1 1.1 C . Ft J II I II LI -1 r- - - - - - —F _ I . I I I I I'I I•I 1'1 I I II II II 11 11 II• I II II II II 11� SEGMENTAL SHEAR WALL ROOF TRUSSES PER PLAN H1 CLIP EACH TRUSS —V SHEAR WALL AT RAISED TRUSS HEEL $ SHEAR WALL SOLE PLATE NAIL/SCREW SHEAR WALL EDGE NAILING FLOOR BOUNDARY NAILING 'ER PLAN SHEAR WALL EDGE NAILING TO RIM JOIST 48"oc EXTEND LOWER SHEAR WALL SHTG. CONT. UP TO JOINT ON RIM JOIST. DO NOT BREAK SHTG. AT DBL. TOP PLATE. SHEAR WALL EDGE NAILING TO TOP PLATE SHEAR WALL TO UPPER FLOOR 112 SHEAR WALL SOLE PLATE NAIL/SCREW SHEAR WALL EDGE NAILING SHEAR WALL SOLE PLATE NAIL/SCREW SHEAR WALL SHEAR CLIPS, OR ALTERNATE PER 15/S3 (4) 10d TO BLKG PRESSURE TREATED SILL PLATE PER SHEARWALL SCHEDULE. BOLT EMBED = 7" MIN. \ `FLOOR JOISTS PER PLAN 2x BLKG AT 48"oc A FOUNDATION PER PLAN If JOISTS PARALLEL AILAR SECTION PER =0R INFORMATION TOWN FLOOR SHEATHING PER STRUCTURAL NOTES CONT RIM JOIST FLOOR JOIST/BLOCKING PER PLAN ALTERNATE SHEAR FLOW AT UPPER FLOORS 113 SHEAR WALL SOLE PLATE — NAIL/SCREW SHEAR WALL EDGE NAILING EXTEND SHEAR WALL SHTG. CONT. DOWN TO SILL PLATE. DO NOT BREAK SHTG. AT SOLE PLATE OR RIM JOIST. SHEAR WALL EDGE NAILING TO RIM JOIST AND SILL PLATE FLOOR BOUNDARY NAILING PER DIAPHRAGM SCHED 2x SILL PLATE FLOOR JOIST NOTE: SEE SIMILAR SECTION PER 20/S2 FOR INFORMATION NOT SHOWN SHEAR WALL TO MAIN FLOOR 1171 ALTERNATE SHEAR FLOW AT LOWER FLOOR 118 IIIII III III III III III lFn ==-IF I=TT= 1==nlI--rr- BLKG PER SCHED AT HORIZ. I'I I.I.- _LI _ _J L _ 11 A•I 1.1 PANEL JOINTS w/EDGE I_ _ _JI II _LI NAILING BOTH SIDES OF I-- I I I r JOINTTYP. II i i it LOCATE VERTICAL PANEL JOINT ON STUD w/ EDGE I I I I I I III I I I I NAILING BOTH SIDES OF I I I I 1:1I I'I I I JOINT 11 II I. -- -- II I1 MIN (2) STUDS AT EACH I I I I I I HOLD-DOWN UNLESS I I I I I I NOTED OTHERWISE PER PLAN OR POST SCHEDULE TYP. STRAP TYPE HOLD - STRAP TYPE HOLD-DOWN CENTER ON RIM JOIST AT UPPER FLOORS TYP. TYPICAL TOENAIL PANEL EDGE NAILING TYP. PANEL EDGE NAILING ALL AROUND OPEINING BOUNDARY NAILING PER DIAPHRAGM SCHEDULE TO RIM JOIST AND BLOCKING CONT RIM JOIST PANEL EDGE NAILING SHEAR CLIP PER TYP. SCHED. EACH FACE FLOOR FRAMING DOUBLE SIDED SOLID BLKG. BETWEEN SHEAR WALL PER JOIST BLKG PLAN PER PLAN TYP. PERFORATED SHEAR WALL SHEAR CLIPS - DOUBLE SIDED SW SHEAR WALL SCHEDULE AND NAILING DETAIL 5 ROOF FRAMING PER PLAN DIAPHRAGM BOUNDARY NAILING CONT.2x SHAPED BLKG SHEAR CLIPS H1 EACH RAFTER PER SHEAR WALL SCHEDULE EDGE NAILING '71�+SHEAR WALL PER PLAN RAFTERS PERPENDICULAR STUD WAL ROOF BOUNDAR RAFTERS LEDGER AND SDS SCREWS PER PLAN HANGER STAGGERED E SECTION AT LEDGER TO STUDS 114 SHEAR WALL PER PLAN BOUNDARY NAIL PER DIAPHRAGM SCHEDULE 2x BLKG. AT 48" ox. 2x LEDGER OR TRUSS TOP CHORD WITH (2) 16d TO EACH STUD IX NOTE: SEE 12/S2 FOR SHEAR WALL CONNECTION INFORMATION NOT SHOWN RIM JOIST FLOOR FRAMING PER PLAN SECTION 119 DIAPHRAGM BOUNDARY NAILING SHEAR CLIPS PER SHEAR WALL SCHED. EDGE NAILING 7 SHEAR WALL PER PLAN RAFTERS PARALLEL ROOF FRAMING PER PLAN 2x BLOCKING @ 28" D.C. SHEAR WALL TO ROOF RAFTERS 110 CONT 2x SHAPED BLKG SHEAR CLIPS PER SHEAR WALL SCHED. EDGE NAILING TO TOP PLATE BOUNDARY NAILING SHEAR WALL SHEAR CLIPS SHEAR WALL EDGE NAILING 10d@4"c 2x BLKG W/ 16d AT 4" c 10d @ 4" o.c. H1 SOLE P E VARIES PER PLAN SECTION 1 1 `j 1 SHEATHING PER STRUCTURAL NOTES TYP BLOCKING EACH END OF SHEAR WALL AND 48" D.C. ALIGN RAFTER/JOIST/BEAM PER PLAN OVER SHEAR WALL SECTION 120 1 Ross Engineering Design Inc JOB # 19088 ryan.ross@rossengineer.com y UE _m=o=Z ? oE d N a F O'O U'y .E O p Z O N O U O O_ 9 m N y O N O. o_ . 2 O O_ N p L O Z Q L .�. y N 2 U y :S m 0 d- E C a W J 0 (n C C C N 9 O OwW _2o3d>,�mc 3c aoi U J O o 6= O J a o g m O w a o W�anrnct a�En`-6 J Q O H O 2/14 2020 N • pD �, og VfAS,�J f p JO �9 8 .aQ 46411 R�'� ��A3 fONAL�'� ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z W W z uj W ~ Q UJ y Z V; 0z O o W Q 0 Wuj m O a �L to O t� O Z111111111111 FILE/ NO. 190807 DATE DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: S2 PRINT DATE 12/9/2019 BEAM PER PLAN BEAM PER PLAN (2) 16d TYP (2) 16d TYP TOP PLATES DBL. 2x TOP PLATES 2x CONT. BLOCKING SHEAR WALL PER PLAN (2) ROWS 16d @ 3" o.c. 2x CONT. BLKG TYP SHIM EACH FACE A34 WITH SD#9 SCREWS BEAM PER PLAN A34 WITH SD#9 SCREWS ROOF BOUNDARY SHIM EACH FACE AS NEEDED AT ALL RAFTER ENDS AT ALL RAFTER ENDS NAILING AS NEEDED (2) ROWS 16d @ 3" o.c. TYP 2x RAFTERS PER PLAN 2x BLOCKING AT 48" ox. POST PER PLAN FULL HEIGHT STUD ROOF RAFTER PER PLAN RAFTER SLOPES MAY BEAM PER PLAN EACH SIDE OF POST. POST PER PLAN 2x STUD EACH SIDE OF POST ATTACH WITH 16d AT 12" ox. VERY PER PLAN RAFTER PER PLAN WITH (3) 16d ATTACH WITH 16d TO EACH STUD AT 12" o.c. RIDGE BEAM TO POST 1 ROOF BEAM TO POST 2 RAFTER TO RIDGE BEAM 3 RAFTER TO ROOF BEAM 4 SECTION 5 ROOF BOUNDARY NAILING 2x CONT. BLKG ROOF BOUNDARY NAILING 2x BLKG 2x BLKG W/ 16d AT 4" ox. 16d TOENAIL AT 6" D.C. 2x BLKG W/ 16d AT 4" o.c. SHEAR WALL PER PLAN ROOF BOUNDARY NAILING 2x PONY WALL SHEATHED FULL HEIGHT SHEAR WALL FLOOR BOUNDARY NAILING PER SW1 PER PLAN FLOOR BOUNDARY SOLE PLATE CONNECTION NAILING PER SHEAR WALL SCHED RAFTERS PER PLAN SOLID BLKG NOTCH TRUSS - N a H1 EACH RAFTER � T NOTCH TRUSS - ^_ a � T NOTE: EDGE NAILING TO \� I OVER LEDGER N OVER LEDGER N SEE 12/S2 FOR SHEAR WALL SOLE PLATE CONNECTION INFORMATION I 2x CONT. BLOCKING I NOT SHOWN FLOOR BOUNDARY NAILING RAFTERS PER PLAN TYP PER DIAPHRAGM SCHED RIM JOIST RIM JOIST SHEAR WALL SHEAR CLIPS T 16d TOENAIL AT 6" ox. CONT RIM JOIST - MONO TRUSS PER PLAN NOTE: MONO TRUSS PER PLAN SHEAR WALL EDGE NAILING JOISTS/RAFTERS PER PLAN SHEAR CLIPS PER SHEARWALL SEE 12/S2 FOR SHEAR WALL SCHED (BLKG TO TOP PLATE) CANTILEVERED TRUSS HANGER IF SPECIFIED CONNECTION INFORMATION TRUSS HANGER IF SPECIFIED FLOOR JOISTS BY TRUSS MANUFACTURER NOT SHOWN BY TRUSS MANUFACTURER EDGE NAILING PER PLAN SHEAR WALL PER PLAN 2x10 LEDGER AND SDS 2x10 LEDGER AND SDS SHEAR WALL PER PLAN A CONT. SOLID BLKG. SCREWS PER PLAN SCREWS PER PLAN FLOOR FRAMING FLOOR FRAMING PER PLAN PER PLAN SHEAR WALL PER PLAN SECTION 6 SECTION 7 SECTION AT PITCH CHANGE 8 SECTION 9 SECTION 10 SEE 10/S2 FOR ALIGN RAFTER/JOIST/BEAM INFORMATION NOT PER PLAN OVER SHEAR WALL SHOWN NAIL STUD TO HDR. PER TYP. HEADER DETAIL FLOOR SHEATHING PER STRUCTURAL NOTES TYP ROOF BOUNDARY NAILING NAIL STUD TO HDR. PER TYP. HEADER DETAIL 18" MIN. 18" MIN. 8d AT 6" o.c. SHEAR WALL SHEAR CLIPS - ROOF BOUNDARY NAILING SHEAR WALL PER PLAN TYP USE A35's INSTEAD OF FULL LENGTH OF BEAM HDU HOLD-DOWN LTP4'S ROOF FRAMING PER PLAN 16d AT 6" o.c. TO BLOCKING 2x BLOCKING HEADER PER PLAN 2x HEADER PER PLAN EDGE NAILING PER PLAN AT STRAP CS16 STRAP BLOCKING AT STRAP (2) ROWS 16d MATCH SHEAR o ADD (2) STUDS BLOCKING EACH END OF SHEAR CS16 STRAP WALL EDGE NAIL SPACING NAIL ALL STUDS WALL AND 48" ox. 2x CONT. BLOCKING TOGETHER WITH 16d AT 8" o.c. SHEAR WALL PER PLAN CONT. 1.75"x11.25" LVL POST PER PLAN (3 STUDS) BEAM PER PLAN. NAIL TO RAFTER OVER SHEAR WALL WITH 16d AT 6" 2x STUD o.c. TOP AND BOTTOM 2x BLOCKING AT 48" ox. PLAN SECTION 1.75"x11.25" CONT. LVL BEAM PER POST PER PLAN POST PER PLAN PLAN. NAIL TO STUDS WITH (2) 16d SECTION 11 SECTION 12 HEADER STRAP TO SHEAR WALL 13 HEADER STRAP TO SHEAR WALL 14 DETAIL 15 ROOF BOUNDARY NAILING RAFTERS PER PLAN — _ a v� LEDGER AND SDS SCREWS PER PLAN TRUSS PER PLAN HANGER PER PLAN Av STAGGERED EACH FACE 16 17 18 SECTION 19 20 Ross Engineering Design Inc JOB # 19088 ryan.ross@rossengineer.com y p Z O N N a Z t0 U y O T O O t U E N C O 2 O J O O -O N� O_ � O N p L Q' Z Q s y N@ U y m 0 - EO C OU w O o m �'- m -o OJ O. nm mO"ao U_ an& a� E a� �a F- E o 0 n d d� F E� d J Q O H 2/14 2020 N • pD JO �9 8 .aQ 46TER�'� `rSIONAL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W W W w z W W Q W y mmi z Z V; oz O W :2 = in 0 Lu W m R c 0 a �L N O t� O Z FILE/ NO. 190807 DATE DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: S3 PRINT DATE 12/9/2019 E EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET S1 HDU HOLD-DOWN ANCHOR SCHEDULE AND S2 FOR SHEAR WALL SCHEDULE MAIN FLOOR SHEARWALLS SCALE: 1 /8" = 1'-0" a NO�a 15/S3 cn I n bk EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET S1 HDU HOLD-DOWN ANCHOR SCHEDULE AND S2 FOR SHEAR WALL SCHEDULE 2ND FLOOR SHEARWALLS SCALE: 1/8" = 1'-0" U z � N C) W Q U C Y 2 .o W d O J 7 U RM� z (o 00N_ W w O a)W m J 0 W li H E O U C v-f 'rr - l l l l l � U y N� L N E N V C Q tq p p @ O. R O t� ~ Z w C N O3 p o U ?.E c 9OW-0.p6@p..@CN6L"@U Ey 5 I Z O a 0 to N- @ N N 'J O) N O aW� E�.NN 0�N-OdCO.=� O @ `p U O W U o 0 o O E o c c 3 8 U J] F C �5 U y o U a a"m m, " o. 5 H a 2 w P an d- o~ E d 2/14 2Q20 N . Ro -h0 10 19 8 46411 a 15Tv v 10NAL�', ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z W 0 L� W me z W W Q L u N Z Z V; o O z o LU = o 0 W 0 0 Mn a� 0 z PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. PRINT DATE 11/11/2019 5:43:17 AM FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE z" dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A 3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL & HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16"x24". (R408.4) • PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS. (R406.3.2) • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. FOUNDATION VENT CALCS. (R408.1) PROVIDE 1 SQ. FT. OF VENTILATION FOR EVERY 300 SQ. FT. OF CRAWLSPACE. FOUNDATION VENTS SHALL BE EXTRUDED, LOAD BEARING 16"x8" VENTS. PROVIDE A MINIMUM OF (1) FOUNDATION VENT WITHIN T-0", BUT NOT WITHIN THE FIRST V-0" OF EACH CORNER OF CRAWLSPACE. ASSUMED VENTS ARE MIN. 15.5"x6" AND HAVE A NET FREE VENTILATION AREA OF .48 SQ. FT. TOTAL CRAWLSPACE AREA = 2781 SQ. FT. / 300 = 9.27 SQ. FT OF NET VENTILATION REQ'D. 9.27 SQ. FT. DIVIDED BY .48 = 20 VENTS. OPTION POWER VENT: T-0" HEIGHT CRAWLSPACE = 8343 CU. FT. / 15 = 556 CFM FAN S NOTE: VENT SIZES MAY VARY AND MESH OR LOUVERS MAY DECREASE THE NET FREE VENTILATION AREA. CONTRACTOR TO VERIFY CALCULATIONS AND PROVIDED NEEDED VENTILATION BASED ON ACTUAL VENT SIZE, DESIGN, AND LOCATION. NOTE ! ALL FOUNDATION WALLS TO BE 8" UNLESS CALLED OUT OTHERWISE. LEGEND STEM WALL — — FOOTING CONCRETE SLAB CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F-01 *16'W" CON'T. (2) #4 CON'T. F-02 16"x8" CON'T. (2) #4 CON'T. F-03 *24"x24'W" (2) #4 EA. WY. F-04 24"x24'W" (2) #4 EA. WY. F-05 *30"x30"x8" (3) #4 EA. WY. F-06 30"x30"x8" (3) #4 EA. WY. F-07 *36"x36"x8" (3) #4 EA. WY. F-08 36"xWW" (3) #4 EA. WY. F-09 80N32"x8" (7) #4 SHORT WY. (3) #4 LONG WY. NOTE: *EXTERIOR FOOTINGS SHALL BE MIN. 18" BELOW GRADE AND REST ON BEARING SOIL. Ai �13 �C) �D) �E) �F) ,,.- lG) lHI l�) l�) lK) l�k^^ 12'-4" 16-6" 8'-OY2" 5'-0" Sv 25'-8" 16'-72" ao Q T-7" 18'-1" 15'-7Y2"ml� 0„ Q101 F-03 N I I I II 13----------------- - - - - - _ _ - -.+ --------- - — — — ��, I I I I I I I I I I I I I SUN ROOM SLAB 4" CO C. SLAB. C° � ! 14'-72" Z-0" o CONCRETE LANDING & STEPS J01, co TO GRADE PER I.R.C. m � O O CONCRETE LANDING & STEPS z ^� Nth ypG 6 o �� TO GRADE PER I.R.C. I �I s� you �z° C4 NI —------------ CD--------- - --- —---------- ---- —�— — — — ------------ -------------------- NO— — — 12�� B LTS 1 1 1co ---- - --J �" ----------I�=LI 11-------I� Nol O BOLTS „ v —1t --- ------ N�--—� �y �y — J 18'-9" �r0 F—,-- -- — -- I I — — j F-02-- --� lo s j =—I F I I I L_I--—---- -- ---- \ \ vi— CTYP 16'-18" CONCR TE STEM WALL F-ON 16"x8"ONCRETE FOOTING — —a (TYP7J.N�5.j — — — — — 11' 8" CRAWLSPACE F I 6 MIL. BLACK V.B. 2 - I - - - - - - - - - - - \ - - - - - - - - - - - -! - - - - - -_-I I - - - - - I - 2 10'-3Ya" J� 17'-6 2" Jti 1 V-5/a F-o8 F-08 I I 1 I I I F-o2 I I I T - — -+� fi-- - - - - -- - - ------L+�--+--L---�---- _--____----� II ��� 1 �, L- +� 1 V-2%" T-52" 10'-52" F-o2 7 - - - - _T - -'� - - - - - - - - - - - ---- - - - - - - - \ - - - - - - - - ------------- - - - - - -- -T------ , -- y I-----T-- 26'-8Ya" I r I I ', � L I I I , MN + 1 I F- � I F-02I I�------- I I 02 L F 0 J 1 r -- %I T-----'I— ---� = ACCESS ��- 7 1 I I I I I 13'-0%" — — — — — — — — — — — — — — — — — — — — — — — — — __7 — -- —� �H - - - 4--------- - -- - - - - --- - - - - - - - - - - ---- - - - 50 � NO BOLTS ACCESS 1 -� ------ ----_ -=-\'J IL- 5 — — — — —---------------------------------- — — —---------------- — — — — NO BOLTS — — — — -- — — I 1 "0ll to N Q CONCRETE LANDING & STEPS N N Q 2 I N 2 El F-03 F-03 TO GRADE PER I.R.C.- 0 A9 r A9 Li -- - - - - - - - - - -i--- - - - - - - - - - ------------------------ - - - 4 - ----------------rt- I I J F- 05 L J �� 1 " 1 " 1 '-8 12'-8 3'-9 I F-05 1 �4'-0" 9'-6" 17'-0" 56'-0„ �¢00 co - Iw la I I R I I� w 0 IZ 3 I ILL I I I I, - - - - - - �A►�iE-SLAB- - - - - - 3 C O \9 !v 4" COI\IC. SLAB. SLOPE MIN.%" I �� PER 1'40 TOWARDS GARAGE DOOR. I I I Co I I I I F 1— —1 F-05 I L 3 - - --------------------------------------------------------- I------------------------------ t------ - - - - LI �-1 j LI I-i Lu °..I 4 Q I I 4 Q -' o �I I z Z FOUNDATION PLAN I I F_ol a a. El SCALE: 1/4" = 1'-0" o I — — TYP� : 2 ---------------------------� - - — — (04 I _ ri t ------ I 5'-52" 16'-0" 4'-6, 2„ 26'-0" C, N 0 CD N CP E0 Lo Co U z � N C) 0 00 Q U C Y 2 .o W d Lou-- 0 J � � U (o z 00N_ Lu 09 o E W m J 0 W a O V + So e, law Z L� N U J Oy c c m aQJo�ocL �mooa�o_a . oLo. ~�Q=- o.� ow ti—cow `oa a`�i .B .o O-Bo- U E N a ° d w O E N w o o- i u o n `� o L N p `° O O w U= o U o o c c 3 d w U J J c o y- o U a o..m O F m E zaim�o�E�a� 2/14 2020 N.po �, ag WAS,aJf�� S, �0 10 19 8 48411 STEg�'4 `YSIONAL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z W W z W W H ad Q (04) 3�- W N z mmi Z �; � O z o W Q Lu Lu W a� m 0 0 6 z PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. S5 PRINT DATE 11/11/2019 5:43:17 AM a QE QF G H � I I I I I I I. , I• I I I — — —--------- — - — - — - — - — - — - — - — - — — — — — — — — — — — — — —------- ° ° ° m • ,I I I I I °•I I ••.I I J K L M -----------------------------t-------- j— — °.I I I I I I I I • i I I• I I I �. SUN R OM SLAB I I° 4" CO C. SLAB. CO�CRETE LANDING & STEPS TO GRADE PER I.R.C. I I I'e CONCRETE LANDING & STEPS TO GRADE PER LR.C. i I Ir I I I I I `°°� �y I °I I I I' I II•••I I!•°I -------- — — — — — — —j------------------- — — — — — ml — ---------- 12 1 -- -- -- ----- — -- - I ---------------------- 1 ---- rt------------- .. • ° L .° I I I ro) rl 11----------------- °. J -- -- - ----- ---- - - - - -- —--I-i ---- - ---- - I .I prO O� SOLID BLOC KING i • ` -� I• H I Q OVER PONY WALL I I -------------------- r _1_•_ _ _______ ________ _�_� I- m .r_- ------ r 1 r 1 r 1 r pro i' Ln °'I I I I I I I \O� I SVOER ONY TALL I I i 1 i '• (C-4 Q I I 1 9 --- ---- — - — -- — — — — ----- — — — !--- -- — --- — - — — — — — --- — ----� I° -- rt — — t I I I I I I I I � pro i •i I I I I � I I o I I I -�Q i°• I I ri i° I I 00 2 2 - - - - - - - - - - - - - - - - - - - i° - - p��8 •' AI H A ------ -_O �—p -----,—— ----— ---- ----,—° — ----------Q,--- O---SA-- — OS-- — ---rI +—+•III : - II �.QI �° ---W-- 2 SOLI BLOCKING OVE PON WALL KII --- —— -- SOLID — - O— —AG L - ---P -W - — ------ --------- ---- _ ___ Z SIN� L---- OLID LOC NG O--L^QID L--OCK NG ER P NY ALL ________NOTE SOLI BLO KINGALL FLOOR FRAMING MEMBERS TO BEPONWAL9.5" BCI 6000 - 1.8 16" O.C. U.N.O. ACCESS 1 A A I •. °.° •°. •.°° ° °• !II1i1 O- -°— VALL ._ OVER ' — — — — — — — — — — LEGEND CONCRETE WALL UNDER -- PONY WALL UNDER - — -- -- --J -- ---- -- - WALLS/ FIXTURES OVER X61 FLOOR PERIMETER FLOOR JOISTS — — — — —— HEADERS & BEAMS O ' CONCRETE SLAB �— ------r -------— ----� ----- J--- -------- --------------------- - - - - - - -- - - - - - - - - - - CONCRETE LANDING & STEPSHANGER SCHEDULE TO GRADE PER I.R.C._ SYM. HANGER H-01 L70 AT SINGLE, (2) L70 AT DOUBLE H-02 LU26/LUC26 -------------------------------- - t •- .' TfiIII!II1II1 -- — - AA21 99 __ -- ; al 321 A�Q93 % a I�fII1IiIIIII1r s°IiI H-03 ITS2.37/14 / IUS2.37/14 H-04 LU210 / LUC210 H-05 LU210-2 / LUC210-2 H-06 ITS2.37/9.5 / IUS2.37/9.5 H-07 ITS1.81/9.5 H-08 HUCQ412-SDs H-09 HU11 H-10 L70 EACH FACE NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER • — IIIIiIL •° ,• °°i'IIIIiI III!IIIII .._.°.p ._IlII r BEAM SCHEDULE SYM. BEAM BM-01 4x8 DF#2 OR BETTER — — — — — — --GARAVf—J" — — L 4" CONC. SLAB. SLOPE MIN. 410 DF#2 OR BETTER PER 1'-0' TOWARDS GARAGE DOOR. BM-03 1.75"x9.5" LVL BM-04 1.75"x14" LVL BM-05 3.25"x14" PSL BM-06 3.5"x10.5" GLULAM BM-07 3.5"x12"GLULAM BM-08 5.5"x12" GLULAM - - - - - - - = - - - - --- - - - - - - ---F----------------------- T---- BM-09 5.5"x13.5" GLULAM � BM-10 5.5"x15"GLULAM BM-11 6.75"x25.5" GLULAM BM-12 2-2x12HF#2 BM-13 1.75"x11.25"LVL 4 iiaI;�IIIIIIIi�iIIPIIIIIir '`. ••°°` • . ° • °°'• - - r1II1IIIII1 — -- - AA34 - MAIN FLOOR FRAMING POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: SCALE: 1/4"=1'-0" P-01 (1) 2x— STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x— STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER —� P-03 (2) 2xTRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. ---_----- P-04 (2) 2xSTUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. ---------------------------------------- (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C.P-05 (3) 2x_ STUDS P-06 (4) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. Ludw P-07 (5) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-08 44 DF#2 (4)16d NAIL (SUB FLOOR) A34 46 DF#2 4 16d NAIL BEAM 4 16d NAIL HEADER � �16? 0 4A)6 9 9 �• y ' i P-10 (4) 2x— STUDS w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-11 6x6 DF#2 (4) 16d NAIL (BEAM) (4) 16d NAIL (TOE PLATE) P-12 (3) 2x6 LSL 1.3E FULL HEIGHT (4)16d NAIL + (2) LS50 (6) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER STUDS w/ (2) TRIMMERS (DBL. TOP PLATE) +A35 INOTE:1 SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE 0 z � N W Co Q � U C CL Y= rn w d W � � c O ":� - 4 U ��0 (M O z O O C N — O W �!! .0 Ix O E W Co J 0 W a O U C we' c I, I O A. N O_ W Z_ p U O N N C O m �. Namo R°ro,~ocT�L�.U-m o H OU@ m C O O CO O O U a U aC CmLm� UOa) S=�NoEO .la0U� awe :E a).amao2 o OWUy._o �6 Enoo0�0 aEyo2w dCU Za2 E ~�o wan m 2/14 2020 N . Ro �, Og VIAS,�Jf 3Q 19 8 46411 �a 'PipGf 5T��4 �rv�� ONAL�', ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z Lu 1� W w z W W ~ Q L u N z V; Q mmi O Z O W :�i Q � W a� cu 0 c 0 .N a� 0 z PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. S6 PRINT DATE 11/11/2019 5:43:17 AM NO CALLOUTS SHALL BE HEADER: BM-01 COLUMN: P-01 (ea. side) LEGEND TRUSSES RAFTERS OVER FRAMING WALLS UNDER WALLS/ FIXTURES OVER HEADERS & BEAMS FLOOR PERIMETER FLOOR JOISTS LANDING JOISTS STAIR STRINGERS LOWER ROOF LINES FLOOR FRAMING HANGER SCHEDULE SYM. HANGER H-01 L70 AT SINGLE, (2) L70 AT DOUBLE H-02 LU26 / LUC26 H-03 ITS2.37/14 / IUS2.37/14 H-04 LU210 / LUC210 H-05 LU210-2 / LUC210-2 H-06 ITS2.37/9.5 / IUS2.37/9.5 H-07 ITS1.81/9.5 H-08 HUCQ412-SDS H-09 HU11 H-10 L70 EACH FACE NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER BEAM SCHEDULE SYM. BEAM BM-01 4x8 DF#2 OR BETTER BM-02 410 DF#2 OR BETTER BM-03 1.75"x9.5" LVL BM-04 1.75"x14" LVL BM-05 3.25'x14" PSL BM-06 3.5"x10.5" GLULAM BM-07 3.5"x12" GLULAM BM-08 5.5"x12" GLULAM BM-09 5.5"x13.5" GLULAM BM-10 5.5"x15" GLULAM BM-11 6.75"x25.5" GLULAM BM-12 2-2x12 HF#2 BM-13 1.75'x11.25" LVL POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x— STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x— STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x— TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (2) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 (3) 2x— STUDS (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-06 (4) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-07 (5) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-08 44 DF#2 (4)16d NAIL (SUB FLOOR) A34 P-09 46 DF#2 (4) 16d NAIL (BEAM) (4) 16d NAIL (HEADER) P-10 (4) 2x— STUDS w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER p-11 6x6 DF#2 (4) 16d NAIL (BEAM) (4) 16d NAIL (TOE PLATE) P-12 (3) 2x6 LSL 1.3E FULL HEIGHT STUDS w/ (2) TRIMMERS (4)16d NAIL + (2) LS50 (DBL. TOP PLATE) (6) 16d NAIL (TOE PLATE) +A35 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER INOTE:1 SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE 0 z — N W W Q � U C CL Y= rn w dFn W � � c O U�� - 4 V ��0 (M O z O O C O N — W �!! .0 lx O E W Co J 0 W a H E O u C .N N — 14, U c Z E N;ZZ_ p U O l6 N o ;lN o°ro,Ho�TU�Ug.--0 HO Jcco2. U0:6 L.0O 2 0. me o o c- o n o _ U O `-�'�cy�� mi��E ; � Z O a� y a� � � m N d rn� d y o c aw : E .y._ o ama o a= o OLu U°°woUoo-m=3cd U UJJLLIHC�pUyoU aa' mOm o Zo-2wPc' 0d-o�-Emco 2/14 2020 N . Ro �, Og WAS,yf�� � �0 10 19 8 46411 a 4 'PipGI5T 10NAL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z LJIIIIIIIIIJ W w z W W ~ Q LJIIIIIIIIIJ N Z V; Q O Z 0 W :�i Q � W a� io 0 c 0 .N a� 0 z PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. S7 PRINT DATE 11/11/2019 5:43:17 AM NOTE ! ALL ROOF FRAMING MEMBERS TO BE 2x12 RAFTERS @ 24" O.C.(U.N.O.) NO CALLOUTS SHALL BE HEADER: BM-01 COLUMN: P-01 (ea. side) LEGEND RAFTERS OVER FRAMING GIRDER TRUSS WALLS UNDER HEADERS & BEAMS ROOF LINES LOWER ROOF LINES LOWER ROOF AREA HANGER SCHEDULE SYM. HANGER H-01 L70 AT SINGLE, (2) L70 AT DOUBLE H-02 LU26 / LUC26 H-03 ITS2.37/14 / IUS2.37/14 H-04 LU210 / LUC210 H-05 LU210-2 / LUC210-2 H-06 ITS2.37/9.5 / IUS2.37/9.5 H-07 ITS1.81/9.5 H-08 HUCQ412-SDS H-09 HU11 H-10 L70 EACH FACE NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER BEAM SCHEDULE SYM. BEAM BM-01 4x8 DF#2 OR BETTER BM-02 410 DF#2 OR BETTER BM-03 1.75"x9.5" LVL BM-04 1.75"x14" LVL BM-05 3.25"x14" PSL BM-06 3.5"x10.5" GLULAM BM-07 3.5"x12" GLULAM BM-08 5.5"x12" GLULAM BM-09 5.5"x93.5" GLULAM BM-10 5.5"x15" GLULAM BM-11 6.75"x25.5" GLULAM BM-12 2-2x12 HF#2 BM-13 1.75'x11.25" LVL POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x— STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x— STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x— TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (2) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 (3) 2x— STUDS (4)16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-06 (4) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-07 (5) 2x— STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-08 44 DF#2 (4)16d NAIL (SUB FLOOR) A34 P-09 46 DF#2 (4) 16d NAIL (BEAM) (4) 16d NAIL (HEADER) P-10 (4) 2x— STUDS w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER p-11 6x6 DF#2 (4) 16d NAIL (BEAM) (4) 16d NAIL (TOE PLATE) P-12 (3) 2x6 LSL 1.3E FULL HEIGHT STUDS w/ (2) TRIMMERS (4)16d NAIL + (2) LS50 (DBL. TOP PLATE) (6) 16d NAIL (TOE PLATE) +A35 16d NAILS STAGGERED @ 12" O.C. (8)16d NAILS STUD TO HEADER INOTE:1 SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE ROOF PLAN NOTES • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. • FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. • SHADED AREAS INDICATE OVER -FRAMING. • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVERALL SUPPORTS. • PROVIDE MIN. 22"00" ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. • 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. • ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING ROOMS. ATTIC VENTILATION CALCULATIONS ATTIC VENTILATION (R806.1 & 806.2) PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 150 SQ. FT. OF ATTIC AREA. EXCEPTION: PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. FT. OF ATTIC SPACE WHEN NOT LESS THAN 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATION AREA IS PROVIDED BY VENTILATORS LOCATED WITHIN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACED MEASURED VERTICALLY WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION OF MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. PROVIDE A COMBINATION OF ROOF JACKS OR CONTINUOUS RIDGE VENTING ALONG WITH EAVE VENTS. AF50 JACK VENTS =. 333 SQ. FT. NET FREE AREA. EAVE BIRD BLOCKS = .074 SQ. FT. NET FREE AREA. CORAVENT V300 = .094 SQ. FT. NET FREE AREA PER L.F. ROOF ROOF AREA = 4697 SQ. FT. / 300 = 15.66 SQ. FT. / 2 = 7.83 SQ. FT. OF REQUIRED VENTING IN BOTH UPPER 40-50% OF ROOF AND IN LOWER 50-60% OF ROOF. IN UPPER 40-50% OF ROOF TOTAL SQ. FT. REQUIRED / .094 = 83.3 LIN. FT. OF CORAVENT V300. IN LOWER 50-60% OF ROOF TOTAL SQ. FT. REQUIRED / .074 = 106 EAVE BIRD BLOCKS 0 z - N W W Q � U C CL Y= rn W dFn W � � c O U�� - 4 V ��0 (M O z O O C O N - W �!! .0 Ix O E W Co J 0 W a IH E 0 u C �1 c 14 U c Z Z_ Nam�ioo,Ho�TU�UEaai�c HOJ:= N �92 g @ U,r�`O L,o 0 o°r 2 R me o.— 2,6 o _ U IZ Oa0),62=_El m rn�d,noc aw, :E .y._ommao 'a=0o OW�U°pwoU"o.m=3c� o 0-LLjffiUmoUaa'�mOmoo Zo-ow�� md�o�E�o 2/14 2020 N . RWA o �0 10 19 8 46411 a 'PipGI5T 10NAL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING RESUB Dec 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W z Lu W w z W W ~ Q L u N Z V; Q O Z 0 W :�i Q � W a� io 0 c 0 .N a� 0 z PROJECT NO. 190807 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. S8 PRINT DATE 11/11/2019 5:43:17 AM