REVIEWED BLD2021-1096+Storm_Drainage_Report+8.9.2021_9.55.10_AM+2345900RECEIVED RAM Engineering 9-13-21 To: Cityof Edmonds CITY OF EDMONDS DEVELOPMENT Engineering DIVISIc n SERVICES DEPARTMENT From: Rob Long, PE RAM Engineering Subject: Adamant Homes, Inc. - 240th St SW Short Stormwater Memo RAM Job No. 19-015 BLD2021-1096 MPmnr;ndum Date: August 5, 2021 COMPLIES WITH APPLICABLE CITY STORMWATER CODE lat- Lc, This memo provides a summary of the stormwater hard surface allocation for Lot 3 of the Adamant: Homes 240th St SW Short Plat (PLN 2019-0052). A site -specific geotechnical evaluation only recommends two possible stormwater BMPs for the site; perforated stub -out connection and BMP T5.13: Post -Construction Soil Quality and Depth. Project impervious/hard surface (roof, driveway, walk/patio areas) will be managed by a shared stormwater detention tank system with the short plat development. The shared detention tank system has been designed as part of the short plat development and thus includes hard surface areas allocated for each individual lot (see Adamant 240t" St SW Short Plat Stormwater Site Plan Report). Lot 3 has an allocation of 3,300 sf of impervious/hard surface, which include roof, driveway, and patio/walkway areas. Below is a stormwater control summary table for Lot 3: Stormwater Control Summary: Project Site Category: Category 2 (part of the Adamant - 240th St SW Short Plat) Discharge Location: City's Municipal Separate Storm Sewer System (MS4) Type of Area Square Footage Storm water Facility Lawn and Landscape 4,808 sf Soil Amendments (BMP T5.13) Roofs 2,368 sf Detention Vault Hard Surfaces 830 sf Detention Vault 25% Retrofit 0 SF None cn H N LO r 00 Adamant Homes, Inc. - 240th St SW Short Plat- Lot 3 Stormwater Memo RAM lob No. 19-015 Page 2 of 2 240th St SW Short Plat Lot 3 Hard Surface Summary: Roof = 2,368 sf Driveway = 800 sf Patio/Walk = 30 sf Total = 3,198 sf 4 PVC ROOF DRAIN 0 1.OX PERFORA 7ED STUB -OUT MIN CONNECTION PER rYTY STD DON NO. SO-639 (SEE DETAIL ON SHT GN-01) . 'CONNECT 70 - so srue Nr53338� 19.f3 4' PVC SIDF SFN£R O 2.OX MIN A t B " I£ 4G4.0 155CD ni ' W D W7H WA MR LINE) SF aooc s NET) 4' PVC AGF & daVr FOO 17MG iSE,laENT (TYP)PROPOSED HOUSE DRAIN mI ;• MAIN FF 407.50 1.0X MIN .I. . j . GARAGE ! I I \ I c .' DRY UTILITIES - SOO ST Ns"6'P W 146.13, ' /// l IF 402.5t INSTALL ON Ij I' SS STUB fo' MIN LENGTH FOOTING DRAIN DRYWELL TRENCH (PER CFo TECH REGDAIMENDA AONS) WPM VATE SENEF SERME EASEVENr i I 'I CIMMERO, A CONDOM1A (AFN 9503301 RAM Engineering 19109 3611 Avenue W, Suite 100 Lynnwood WA 98036 (425) 678-6960 RAMengineeringinc.com