APPROVED STM BLD2021-1103+Storm_Drainage_Report+8.9.2021_11.30.01_AM+2346411RECEIVED RAM Engineering 8-13-21 To: Cityof Edmonds CITY OF EDMONDS DEVELOPMENT Engineering Division SERVICES DEPARTMENT From: Rob Long, PE RAM Engineering Subject: Adamant Homes, Inc. - 240th St SW Short 1 Stormwater Memo RAM Job No. 19-015 BLD2021-1103 Memorandum Date: August 5, 2021 OMPLIES WITH APPLICABLE v7 CITY STORMWATER CODE c~n H Oo J � CV )t4 This memo provides a summary of the stormwater hard surface allocation for Lot 4 of the Adamant Homes 240th St SW Short Plat (PLN 2019-0052). A site -specific geotechnical evaluation only recommends two possible stormwater BMPs for the site; perforated stub -out connection and BMP T5.13: Post -Construction Soil Quality and Depth. Project impervious/hard surface (roof, driveway, walk/patio areas) will be managed by a shared stormwater detention tank system with the short plat development. The shared detention tank system has been designed as part of the short plat development and thus includes hard surface areas allocated for each individual lot (see Adamant 240t" St SW Short Plat Stormwater Site Plan Report). Lot 4 has an allocation of 4,450sf of impervious/hard surface, which include roof, driveway, and patio/walkway areas. Below is a stormwater control summary table for Lot 4: Stormwater Control Summary: Project Site Category: Category 2 (part of the Adamant - 240th St SW Short Plat) Discharge Location: City's Municipal Separate Storm Sewer System (MS4) Type of Area Square Footage Storm water Facility Lawn and Landscape 8,993sf Soil Amendments (BMP T5.13) Roofs 2,368 sf Detention Vault Hard Surfaces 1,780 sf Detention Vault 25% Retrofit 0 SF None Adamant Homes, Inc. - 240th St SW Short Plat- Lot 4 Stormwater Memo RAM lob No. 19-015 Page 2 of 2 240th St SW Short Plat Lot 4 Hard Surface Summary: Roof = 2,368 sf Driveway = 1,750 sf Patio/Walk = 30 sf Total = 4,148 sf ro• SEHER FA E&FXi ZRAAN pRr*lL Tf? NCH 4' PVC .- avc . �. I AWALL 4W �T aEaT�Cff "' a g SS sr i fEGtl E+MdA �GwSJ rat s�WN 2-ox &W PERrORArP.'A.SnO-our _ A $ ccragEclm PERL7TY' STD _ _ 9 I D RU No. 5t�6.i19 i I ,$ (sne mmk AV _,wr crr-ar) 31cn rf d r4f4f sF f " P u� RfjLir 1— y' PRa'05W hw5F MAN Pr 4M.30 + l' GARACE WAICR 5ER6}(I� LM 4"8 it Nri4f TO RE LED MTN WAMW LANE) r r JD �,75i1 sF i AREA A4AW AJ8grejo ' TOabP DRY UnUnF5 — — — - -' 4" 9 #af-SO - N8r�7Q8'3r'w - 36,87' - +F ;RTZ WSFALL dJ 5.4 STUB r-1 +I IIr 111 I I 00463, �ill� f f O' PRrVi4 iF � XER jrA.:£ Mr jSEIROM TO"PRIVATE Sy4L+ LkiAN1AG'�' FA�EuErL r 2,36 s M15rALlID Y X 3' OR YitEL MrH 414" 70 f-f%' %WAN I RDrK FM wAP ORAN RAM Engineering 19109 3611 Avenue W, Suite 100 Lynnwood WA 98036 (425) 678-6960 RAMengineeringinc.com