APPROVED BLD PLN RESUB 1-Architectural PlanCV
LL
CV
�o
3
A2.1
11'-b 1/4"
2'-9 1 /2"
,�
------ -
L
�____�
DBL RIM BD. ABOVE
�
_�_�
�____ _
_�
;
'
T-----------
--'
�
AVOID BUILDING ABOVE
L�� � J
L__�_J
'
___
�
L____�
SEWER CLEANOUT
r_i_
III
-
'�
((EXST'Gl
i i
�
r-
-�
� �
��
��
i i
it (V
r i -i-�
i i
i
�
i
i
- -
i
L �J_
��
�-
-
•. .' • .' - ..
.. .. ..
EXST'G,WNDW
�-,
;'EXST'G WNDW
�
w�',
- �•
. .
. -.. •. • . :: ,'... . •
•`
�
EXSTG DOWNSPOUT
' � GARAGE
•
_ • .
m��
..
_•'. _•'
� �
i i
_ - .
�'
•
�, r-�-
'
-
'
-
-..
.. _ •. .. •. L�
- • - �
I
L �L _I_J
I I
_ •.
• -
•m
'
O'
'��
I� �
._
- •--. •- •- _ -..�
- w.
'
6 x 6 POSTS � �
. . - � >
rr�
7
-•. _ .. _ �
L _
i I -------------------------
. _ . -_ � ¢ EXSTG HOUSE -
' '•' • • NO MODIFICATIONS
� I I • • - • • _ •�•
- _ _
I, - .._ -
• _' - . EXSTG CONCRETE PAT_10_
', ".312SF
,�••-
• NOTE: INSTALL AND MAINTAIN ALL
•_ . ,_ - - _ - . _ - TESC MEASURES ACCORDING TO
I � : � .
Lr; -',-J � • - ' : _ • - • • • • - - ; _ • - APPROVED PLANS, CITY OF EDMONDS
• . • _ ' _ • � _ w STANDARD DETAILS, AND ALL OTHER
' • • � � � MEASURES THAT MAY BE REQUIRED
' ' . '.' • � •' . '.' . • "' DURING CONSTRUCTION.
_ _ O
', •. �--• CUT &PATCH EXSTG CONC . � •� •' x
:'• '•' PATIO SLAB AS NEED FOR . _ - • ,' '-'-'
r L_,_ 'FOOTINGS _ -
�r�� •• •• _- .... -- .
�, - _ • _ - •
L __J -
OV•ERi-iQ G TO fDG•E QE DECK ABO�fE- •- .. _ - •_ - - .- . ,. •_ ,. ,. _ - • ,
•• • -. • --- _ • . •• _ • -. • -- _' • . .• •Ei(ST'G S1DE�NAJ_K• •• ••..•. •• • _ .�_ - - •� ••. •�. "_ - ' ' _ _ - '•'
3
A2.1
BASEMENT PLAN
GENERAL NOTES
NORTH
SCALE: 1 /4"=1'-0"
l . ALL CONSTRUCTION SHALL OBSERVE AND COMPLY WITH ALL THE FEDERAL, STATE, AND COUNTY'S LAWS, REGULATIONS, ORDINANCES, BUILDING CODES, SUBSEQUENT COUNTY AMENDMENTS TO THE
PREVAILING INTERNATIONAL RESIDENTIAL CODE (IRC) SECTION 507 .
2. THE CONSTRUCTION DOCUMENTS CONTAINED HEREIN ARE A REPRESENTATION OF THE DESIGN INTENT AND DO NOT INDICATE "ALL" THE BUILDING CONDITIONS AND/OR BUILDING COMPONENTS
REQUIRED FOR THE CONSTRUCTION OF THE PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO THOROUGHLY REVIEW THE DRAWINGS AND SPECIFICATIONS TO VERIFY ALL THE MATERIALS REQUIRED FOR
THEIR RESPONSIBILITY OF THE CONSTRUCTION OF THE PROJECT AND TO INDICATE THIS IN THEIR CONSTRUCTION BIDS. IT IS ALSO THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL THE CONSTRUCTION
CONDITIONS OF THE PROJECT AND TO REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE CONSTRUCTION COMMENCES.
3. THE CONTRACTORS SHALL CAREFULLY AND THOROUGHLY REVIEW THE DRAWINGS, SPECIFICATIONS AND OTHER CONSTRUCTION DOCUMENTS THAT PERTAIN TO THEIR SCOPE OF WORK AND SHALL AGREE
BEFORE SUBMITTING A BID OR COMMENCING WITH CONSTRUCTION, THAT THEY HAVE FOUND THE DRAWINGS, SPECIFICATIONS AND OTHER CONSTRUCTION DOCUMENTS TO BE FREE FROM AMBIGUITIES AND
SUFFICIENT FOR THE PURPOSE INTENDED.
4. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, EXISTING ELEVATION HEIGHTS, PROPERTY LINES, SETBACK LINES, EASEMENTS, UTILITY LOCATIONS AND ALL CONDITIONS THAT
COULD IMPACT THEIR WORK BEFORE ANY CONSTRUCTION COMMENCES. ANY DISCREPANCIES OR CONDITIONS THAT COULD AFFECT THE PROJECT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION BY THE
CONTRACTOR BEFORE PROCEEDING WITH THE WORK.
5. ALL TRADES SHALL REFER TO THE COMPLETE SET OF DRAWINGS REGARDING THE LOCATION OF THEIR WORK TO BE INSTALLED.
6. ALL DIMENSIONS ON THE DRAWINGS REFERENCING NEW WORK ARE TO FACE OF STUD, TO STRUCTURE, TO CENTERLINES, OR EDGE OF CONCRETE AS SHOWN, UNLESS OTHERWISE NOTED. ALL
DIMENSIONS ON THE DRAWINGS REFERENCING AS -BUILT WORK ARE TO FACE OF WALL. AS SHOWN. ALL DIMENSIONS ARE TO BE TAKEN FROM THE DRAWINGS AS NOTED AND UNDER NO CIRCUMSTANCES,
SHALL THE DIMENSIONS BE GRAPHICALLY SCALED FROM THE DRAWINGS.
7. ALL MANUFACTURED MATERIALS, EQUIPMENT, AND ANY OTHER BUILDING COMPONENTS BEING INCORPORATED INTO THE CONSTRUCTION OF THE PROJECT SHALL BE INSTALLED IN ACCORDANCE TO THE
MANUFACTURER'S WRITTEN INSTRUCTIONS, UNLESS OTHERWISE INSTRUCTED BY THE ARCHITECT.
�. ALL WORK INCIDENTAL TO THE SUBCONTRACT AND NECESSARY TO COMPLETE THE PROJECT, ALTHOUGH NOT SPECIFICALLY REFERRED TO ON THE DRAWINGS OR SPECIFICATIONS, SHALL BE FURNISHED AND
PERFORMED BY THE CONTRACTOR.
9. THE CONTRACTOR IS TO VERIFY ALL OF THE DIMENSIONS ON THE DRAWINGS FOR ACCURACY AND THEIR RELATIONSHIP TO OTHER SCOPES OF WORK AND IS TO REPORT ANY DISCREPANCIES TO THE
ARCHITECT BEFORE CONSTRUCTION COMMENCES AND/OR BEFORE PROCEEDING WITH ANY WORK. SHOULD DIMENSIONAL CONFLICTS OCCUR, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND SHALL
WAIT FOR CLARIFICATION BEFORE RESUMING OR COMMENCING WORK ON THE ITEM WHERE THE DISCREPANCY OCCURS.
10. THE CONTRACTOR IS TO VERIFY ALL PENETRATIONS, OPENINGS, STUB OUTS, INSERTS, OR ANY OTHER ITEM THAT IS TO BE INSTALLED IN CONCRETE OR ANY OTHER SCOPE OF WORK THAT WOULD REQUIRE
REMOVAL TO INSPECT THESE ITEMS BEFORE CONSTRUCTION COMMENCES.
1 1. THE CONTRACTOR SHALL OBSERVE AND COMPLY WITH ALL THE FEDERAL, STATE, AND COUNTY LAWS REQUIRED FOR THE PROTECTION OF PUBLIC HEALTH, SAFETY, AND ENVIRONMENTAL QUALITY.
12. THE CONTRACTOR SHALL ESTABLISH AND MAINTAIN AT ALL TIMES, ALL PROTECTIVE MEASURES AS REQUIRED TO SAFEGUARD HIS EMPLOYEES, THE PUBLIC, AND ALL OTHERS FROM BODILY HARM OR DEATH
RESULTING FROM ACCIDENTS DUE TO CONDITIONS IN THE BUILDING, ON THE SITE, OR FROM OPERATIONS RESULTING FROM THEIR WORK UNDER THEIR CONTRACT.
.;
O
m
U
z
O
c�
X
w
U
w
0
0
w
U
3
A2.1
12'-0 " 17'-7 "
5 3/4" 11'-b 1/4" 2'-9 1/2" 9'-11 "
LANDING &STAIRS
142 S F
5'-5 1 /2"
5'-5 1 /2"
EXSTG ROOF OVERHANG
,�
SPACED
GUARD RAIL
COMPOSITE ALI N POST FACE DN
DECKING & VERHANG
EXSTG WNDW
o
Z
(V
DECK �
I 392 SF �
�o
N
w
ALIGN POSTS W/
z
EXSTG ROOF BEAMS
=
TYP. ALL CONDITIONS
�
� w
> o
O EXST'G ROOF
L.L_
BEAMS ABOVE C�
�
�
�_ �
�
w
LL
_
~I
+
(n
_ " - -
0
7�_b��
N
L�
�o
- I - - -
z
�
SPACED �
�o
COMPOSITE w
DECKING
EXSTG WNDW
I
5'-51/2"
5'-51/2" 7"
12'-0"
MAIN LEVEL DECK PLAN
3
A2.1
� ww war ww war ww war ww war ww war
IMPERVIOUS SURFACE NARRATIVE &NOTES
THE TOTAL ARE OF THE SPACED DECK AND STAIRS IS 534 SF. THE EXISTING ROOF COVERS
314 SF OF THE 534 SF OF SPACED DECK AND STAIRS LEAVING 220 SF OF SPACED DECK AND
STAIRS. THE EXISTING IMPERVIOUS CONC. PATIO BELOW ACCOUNTS FOR 92 SF OF THE 220
SF LEAVING 128 SF OF SPACED DECK OVER LANDSCAPING OR GROUND.
NEW IMPERVIOUS SURFACE WILL BE NEW FOOTINGS AND CONCRETE PATCHES TO
THE EXISTING PATIO.
TWELVE (12) X 12" DIA. FOOTING STEM = 12 X .785 SF = 9.0 SF
ONE 12" X 10' CONTINUOUS FOOTING = 10.0 SF
THREE (3) EXISTING CONC. PATIO CUT OUTS TO BE PATCHED @ 2.5 SF EA. = 7.5 SF
FIVE NEW CUTS AND PATCHES INTO PATIO @ APPROX. 1 SF EA = 5 SF
TOTAL NEW IMPERVIOUS SURFACE FROM FOOTINGS AND PATCHED EXISTING PATIO
SLAB IS 31.5 SF
City Of Edmonds
Building Department
Work DECK
Address 18004 73RD AVE W
Owner BURGERS
Approved Date 09/24/2021
Building Official /VQ,��%� ���� �Q,ed�
Permit Number BLD2021-1156
4'-5" 51/�"113"
ROOF OVERHANG
"
=
I
�/����_r
`/
�
�
BENCH
�
Q
HANDRAIL
�
W
COMPOSITE DECKING
�
o
~
�
I
_��
x
� EXSTG DECK
o
— _ _
LANDING
�'IL
I I
J
"'
C�
1 1 RISERS @ 7"
COMPOSITE
i I
I
x
w
10 TREADS @ 1 1 "
DECKING
'CUT STAIR AROUND
EXSTG DOWNSPOUT
NOTE: STAIRS, LANDING AND
BENCH SI SPACED COMPOSITE
DECKING WITH LANDSCAPE BELOW
EXSTG HOUSE -
NO MODIFICATIONS
REPLACE EXSTG RAILING
MATCH NEW DECK RAILING
APPROVED
PLANS MUST BE
ON JOB SITE
City of Edmonds
Building Department
APPROVED Plans
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
EXSTG ROOF OVERHANG�R
r-------------------�
I Hardware and fasteners in contact with
preservative -treated wood shall be of ■
hot -dipped zinc galvanized steel, I N�JRTH
stainless steel, silicon bronze or copper.
.In the absence of manufacturer's recommendations
Ia minimum of ASTM A 653 type G185 zinc -coated I
galvanized steel, or equivalent, shall be used. ■
LIRC R317.3.1 IBC 2304.10.5.1 I
-------------------
PROPERTY �WNERSc
PROPERTY ADDRESSr
PARCEL NUMBERr
LEGAL DESCRIPTI�N�
LET AREAS
Z�NING�
HOUSE AREAr
BASEMENTr
GROUND FL��R�
ATTACHED GARAGEr
TOTAL DECK SURFACEr
DECKr 392 SF
STAIRr 142 SF
TOTAL
(HOUSE, GARAGE
& DECK)
LET CAVE RAG E
SCALE: 1 /4"=1'-0"
T�DD BURGERS & NIC�LE L KELLER
1 �004 73 RD AVE W,
EDM�NDS, WA 9�026-5516
00477500005100
H�MEVIEW ADD N� 1 BLK 000 D-00 -LOT 51
9470 SF / .22 ACRE
RS-�
3904 SF
1697 SF
2207 SF
APPROVED BY PLANNING
462 SF ��� ��
534 SF Sep 23 2021
491 1 SF
2752 SF = 9470 SF = 29%
RESUB
Sep 16 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
M
N
r\
3 � .ri
� N �
O �p
C W N
m
C I�
3 �
u,
� � N
M O V
o E
E
O
T
0
.�
U
w
J
W
�
�O
O
�
O�
Q
w
�
�
M
(/)
�
�
Z
O
M
�
�
Revisions
No.
Date
#1 Submit
#2 Revision
8/19/2021
9/14/2021
#3
#4
#5
Drawn by: BEO
Checked by: BEO
PLANS
Drawing:
Al .l
13. IN THE EVENT THERE IS A DISCREPANCY BETWEEN ANY OF THE DRAWINGS, THEN THE CONTRACTOR IS TO NOTIFY THE ARCHITECT FOR CLARIFICATION ON HOW TO PROCEED WITH THE WORK.
3
cn
J
J
� N
W �
> `f'
O �
M
O
N ('7
�j
0
N
�o
�o
OVERALLS
POSTS 1 5 3/4"
3
A2.1
29'-7 "
rt---�
I �
I I _ _ _
I 118u
b ��_�
b+b c��b
14'-3"
9'-4"
5'-0 1/2"
5 3/4"
-9 1
----------
I
tk
I
��
�
i
;
�-----
L----- --
12C
r-�--,
I '
I
�J�` �
Q' r----,
I I I I
I � I
I I I
_J 1 811 1 OII I ____J I
I
6L L_�
���Q6 I
��
�+�
J
__
_ �
I
� I_ � T----T T ----�
I I I — —_ I
� — — -AVOID BUILDING ABOVE
_ _
�;___�1
_ _
gel 1 g�� � � �
�I 18" SEWER CLEANOUT
b+b ��bb b+b J��----
��
�,�
III
ALIGN POST FACE &OVERHANG
�,� P�
18" r--
_ �
-
_
�
�EXST'G`
�Hv
r I -
I
1
I
I
O
I' I N
I
II
I
r 1
1�- -
J O
11 �.J
b�
bG�s
•
•• -.
III
..•
' • •. , .' •- - ' •• • •- , .' - • 1'_'
• _ • • _ _ _ • •
NOTE:
1. ALL POST TO BE PT 6 X 6 DF #2 UNO
..
4
-• -- -• --
• : _ ' � _• •• _ _ " •• : _ ' � _• ,• _ •• �• :
:.
2. ALL LUMBER TO BE 2 X DF#2 UNO
A2.1
I III
_ _
•' • • •' • • • '•'I.
9'-5"
I
I _
�,� III
• : _• _ _ . • • -• _.1Q .
•
. _ -� : �JCSTG �ONCR�Tf P,�CIO' "-'-'
'•
III
_ _ -.. _, _IO'
- -
�•
r} � ' ' • - ' ' � ' 1 EXST'G HOUSE -
I •I -
J j�.l .- . • • - -,• .'.' _ . : ' . _ _ , ' �'•• NO MODIFICATIONS
= III - •• , EXST'G CONCRETE PATIO:. �:
�� III .. .: 31 SF -.. •
•.
r �� � • . ' • _ � . ' • • .•• . NOTE: INSTALL AND MAINTAIN ALL
' t - - _- _' . ,�,• . TESC MEASURES ACCORDING TO
I .I • • .•_ _ • � • • •
�•181=_.•-FOOl?hdG RER PLflN -' • - - • - r • APPROVED PLANS, CITY OF EDMONDS
b b� - . 'S�� DETAIt.QN EI�GINf�R'�- • ' . � STANDARD DETAILS, AND ALL OTHER
b+ �,Q MEASURES THAT MAY BE REQUIRED
L� III •. STRU�TURAt GAL'CU�ATfON• ' _ • •.-' DURING CONSTRUCTION.
�o
III - • "••••'•••••• ' •: �• • '•�''•��•.' •'I
• '- . •.CUT &PATCH EXST'G CONC • '. •--
PATIO SLAB AS NEED FOR : ; -' �'••
r � � �_• • _ : 'FOOTINGS • _ - •_ ,• �• .
• •. _ -. ••---_-' • .••• • ••-. •'-- _' • .•.• •EiCST:G51DEyVA1K: •• -,•-�••_- .' ••
3
AZ2.1
BASEMENT FOOTING PLAN
15'-1 "
EXST'G FENCE &GATE
N,JRTH
NOTE
FOR FOOTING SCHEDULE -SEE DETAIL 3 / A3.1
5'-2 1 /2" 9'-101 /2"
11 " 11 " 11 " 11 " 11 " 1'-4" 1'-4" 1'-4" 1'-0 1/2" 3" 5�
b
b
-
In n n n n n n
Q II I'Q II II II II II
+ 12" W CONT. FOOTING ' ' + ' ' ' I ' ' ' ' ' '
QA II II Q II II II II II
n n
II II
' ' ' '
II II II
I
� _
�
��((�� II II A � II II II II
II II II
� �
2 x 4 PONY WALL OVER I I I I I I
I I I I I
I
=
�
, I , I
-- ---- I I I I ----, I--, I I I I I I I
I � 4 x 10 BEAM �� I I I I I I I I I I I I I I -
- I I I I I
I I I I I
``nn
I V -
I z �
'w'n
I - I II 1 - I II V II ^
-=nr=----n------=rT------TT-------- --
I --- ---- -------------------- n rr z rr �
r II II II
� rr rr rt
�
1 I I I I I I I
I --I II_ _ _ _ _ _ _I I -------I I -------I I_ _ _ _ _ _ _� II I -, T � � Imo/ I I I I I � I I N
I l l-f� I II I I I I I I I II I I `I I �
N
I I I I I
(/� I I I I I
I N
I =
N
I I I I I I I I I
I I I I I I I I I I I I I I II I I � I' I � I ' I I I I I I LJ.J
L- � H}-� � I I I I I I I I�� I � L -- ---J Nam^ (n
0 I I I I I
Q I I I I I
L.I.J
I
I r �
X
'
�' � �� �� 2X4BENCHJOISTS ill ll� � II '-'r '-' �
II X II
� '-' '-' "
� II II II
N
Q.
CV
„ �
I I I I I I I I I I I I I I I I
6 III II II II II II II 6L II ;II N ill
+6 I I I I I I I I I I I I I I I � T 6 I I
II II
� ill ill II
II II II
_
-
N O�� �
_J Q
A III II II II II II II I A
O i i i i i 2 x 6 PONY WALL OVER i i i t l i ill � r i I I I I
�� "� I I I I
I I I I ''
I I I I I
I
I I I I I I I � � I
III I I 6 x 8 BEAM I I (2) 2 x 12 STRINGER TYP. ' l ' l z
- I I -I --I I� I I I I I I I --___I I I I Q
��
' l ' l
I I I Ir I
b+0
e
_
I
�
------'- --�1-
______.__+__._i
-
__ _
-- --
_____
----
____�_____
----- - - _ ----��
-'---- ----
___ I____ _____I ____
----
_____
--
_ __
l � rl rl rl� _-_r
�
_ _ _ _ _ _ _
� II
_ _ _ _
II
_ _ _ _ _
_ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _
_
i
I
� I I I I I II
i
I, � I I I I I I�
� I
I �
� I
I I I �
I
r
I`
r
'_ _I_ _ _ _ _ 1l _ _ _ _ _ _ 11 _ _ _ _ _ _ 1� c
� I
_I_____II]II -'�_
L� I I__--
____
J
_____
____
_____ ___ ______ _____� ____
b x 6 GUARD RAIL POST
_____
___
`I I I__
--- � I I
__I____7r______�r______�TI 4��11
J � I (2) 2 x 8 HEADER L_____I
I I � �
I
I J
I I I I
I � III
I W III
I
III
III
III
I
II II II „
� II II II II
II II II II
I
0
m
p III
I Q III
- - - - - I - -
- - - -
- - - - -
- - - -
- - - - - - - - - - - - - - - - - - - - - - - -
- - - - -
LII
- - - ��
w
Q II II II II
I I I I I I ,
CC
L
I
w � � -
----J-----
----- I
-ri1
Q I I I I ,
�
I
o
III
� o II � �
I.
1 1 RISERS @ 7
; ; ;
_ �; 2 X 8 PLATFORM JOISTS �
I �_ o
Ln
L � I I I
DN
I I
� I I I I I I I
I X L.f)
�,�� X I I I
I �,, ���
IOTREADS@11"
I I
���
III
X I I I I I I I
N II II II II
II II II
I
`�' �'�
III
-I----N 11 H---�
----
-----
----
---- ----- ----
'
-----
---LIB
II
N I I I I I I I
O
I � Q
-�--- 1 I r - - -'
----
-----''
----J--2
----- -- - - -� - - - -
- - - - -
- - - rl1
�� I I I I I I I
I L.
V
III
� I I I
� III
'
x 12 STRI NGER TYP.
III
I I I
III
II II II II
I I I I I l r-----I
II II III II
-`71
I -,b+
I
I
III
' III
I I I F _ _ _
I
---
_ _ _ _
----
_ _ _ _ _
-----
_ _ _ _
----
_ _ _ _ _ _ _ _ _ _ _ _ _
--------------- ----- ----
_ _ _ _ _
-----
III
III
_ _ _ LIB
---r��------
II II III
II II III
I I I I I
I � 2 X 8 LEDGER I � I
I I
I I
I I
-'------Iw
_u__ _lli__ �
� �
1/2' 11" 11" 11" 11" 11" 11" 11" 11" 11" 11" 5'-01/2"
14'-5 1 /2"
NOTE
N,JRTH
ALL DIMENSIONS TO FACE OF FRAMING
OR POSTS.
ALL LUMBER TO BE PT HF#2 U.N.O.
2x4 PC
4x10E
POSTS
W/
�„
w � �
}Z
mo
w ~ �
3=
�U�O¢
w �
w3
� Q \
V
�
O
��
m
0° a
N
u~i
r\
V
w
0
w
J
J
W
W
m
3 � .ri
� N �
>o
C W N
P M
C I�
3 �
u,
� � N
M V
O
o E
N W
0
C
T
3
O
m
O
W �
Q
0
M 0
� Z
O
� W
Revisions
No. Date
#1 Submit 8/19/2021
#2 Revision 9/14/2021
#3
#4
#5
Drawn by: BEO
Checked by: BEO
FRAMING PLANS
Drawing:
DECK STAIR RISER AND TREAD PLAN
SCALE: 1/2"=1'-0"
DECK STAIR &FRAMING DIAGRAMS
SCALE: NO SCALE
A1.2
NORTH ELEVATION
2x6CAP
b x 6 RAILING POSTS
VERT. CABLE RAILING @ 3.5" O.C.
DECKING
2 X1 O JOIST @ 16"OC
(2) 2 X12 RIM BD.
LUS26
CC66 TYP. W/ ECC66 @ENDS
6 x 6 POSTS
3
A1.2
MODIFICATIONS
Q
M
MAIN LEVEL F. FL.
(V
i
MENT LEVEL F. FL.
SCALE: 1 /4"1 '-0"
I I I I I I I I I I
I I r L__ J, r L__ J, l__ J r L__ J, r L__ L, r L__ J,
I I I I I I I I I I I I
I I
L _ _ J L _ _ _ _ J L _ _ _ _ J L _ _ _ _ J L _ _ _ _ J L _ _ _ _ J L _ _ _ J
WEST ELEVATION
SCALE: 1 /4"=1'-0"
ri--;, rL--;, ri--;, ri--;, rL-'-j, ri-'-;, FOOTING PER PLAN
I I I I I I I I I
L _ _ _ _ J L _ _ _ _ J L _ _ _ _ J L _ _ _ _ J L _ _ _ _ J L _ _ _ _ J
RESUB
Sep 16 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
EXISTING RESIDENCE SHOWN SHADED
�
W � �
} Z
m0
h
w ~ �
3=
�U�O¢
w �
w�
� Q \
V
�
O
��
m
0° a
N
u~i
�
�
V
w
0
w
J
J
W
W
m
Revisions
No.
#1 Submit
#2 Revision
#3
#4
#5
3 � u,
� N �
O �p
C W N
P M
C I�
3 �
u,
� � N
M C V
O
o E
E
O
CJ
C
T
3
0
c,
m
■
A
M
1
0
m
�O
0
0.
W Q
Q
0 �
M �
� Z
�CC
� L
� 0
06? W
Date
8/19/2021
9/14/2021
Drawn by: BEO
Checked by: BEO
ELEVATIONS
SECTION
Drawing:
SECTION DETAIL @BEAM &RAILING
SCALE: 1 1/2"=1'-0"
SECTION THROUGH DECK
SCALE: 1 /4"=1'-0"
A2.1
Ledger Bd. to Rim Bd. Alternating Spacing O.C.
Joist Span
3/8" m
lag bolts/wshr'`
#14 x x4"
wd. screws
(2) Simpson
SDWS 1/4" x 4"
0 < span <_ 8'
18"
18"
18"
8' < span < 10'
15"
15"
15"
FLASHING BEHIND BLDG. PAPER
& OVER LEDGER BD.
DECKING
HANGER Co3 DECK JOIST
FOR ATTACHMENT SEE
SCHEDULE BELOW
EXST'G RIM BD.
SIMPSON DTT1Z -TENSION TIE
INSTALL PER MANUF. INSTRUCT.
2 X LEDGER >_ THAN JOIST Z
FLASHING BEHIND BLDG. PAPER �
& OVER SIDING
EXST'G WALL �^
NOTE:
Contractor to field verify adequacy
of solid lumber for ledger to wall
attachment.
NOTE:
10' < span <_ 14'
10"
10"
10"
Ledger fastener spacing may be
14' < span < 16'
g"
g��
g„
offset up to 3" to avoid interference
with joist attachment.
'The tip of lag screw shall fully extend beyond inside
face of rim joist
�� LEDGER BD.
@WALL RIM
BD. ATTACHMENT
R
SCALE 1 1/2" = 1'- 0"
SILICONE SEALANT TO RESIST
LEDGER. DECAY
DECKING
HANGER @DECK JOIST
1/2" O APPROVE EXPANSION,
EPDXY OR ADHESIVE
ANCZHORS W/ WASHERS.
EMBED. PER MANUF. INSTRUCT
2 X LEDGER >_ THAN JOIST
EXST'G CONC.
JOIST SPAN
BOLT
SPACING
0 < SPAN <_ 8'
18"
8' < SPAN <_ 10'
15"
10' < SPAN <_ 14'
10"
14' < SPAN <_ 16'
9"
NOTE:
Ledger fastener spacing may be
offset up to 3" to avoid interference
with joist attachment.
LEDGER BD. @ CONC. FNDN WALL ATTACHMENT
I PER SCHEDULE I
FOOTING DETAIL &SCHEDULE
��
SCALE 1 1/2" = 1'- 0"
POST PER PLAN W/ SIMPSON
PBS POST BASE OR EQ -
INSTALL PER MANUF. INSTRUCT.
12" DIA. CONC. STEM SLOPE TOP
TO DRAIN
FOOTING SCHEDULE
#
HxWxD
Re -Bar
18
10x18x18
(2)#4 Ea. Way
20
10x20x20
(2)#4 Ea. Way
24
10x24x24
(3)#4 Ea. Way
30
10x30x30
(3)#4 Ea. Way
32
12x32x32
(4)#4 Ea. Way
36
12x36x36
(4)#4 Ea. Way
12C
12x18 Cont.
(2)#4 Cont.
ALL FOOTINGS TO EXTEND 18"
BLW FIN. GRADE U.N.O.
STRIP ALL WD. FORMS BEFORE
BACKFILLING.
SCALE 1 1/2" = 1'- 0"
P.Tt BEAM PER PLAN
SIMPSON PC4 / PC6 BASED ON
BEAM &COLUMN SIZE
4-16d NAILS C EA. FACE &
CONNECTION
2 x 4 P.T. KNEE -BRACE EA. SIDE
4-16d NAILS C�? EA. FACE &
CONNECTION
4 x 4 P.T. POST PER PLAN
GUARDRAIL AND BALASTER DETAIL
2 x 6 WD.CAP
CONNECT BTTM RAILINGS TO
POSTW/ (2) #10 x 3" SCREWS
OUTSIDE TOP RAIL
INSIDE TOP RAIL
4 x 4 GUARD POST
MTL. VERTICAL BALUSTER
3 3/4" GAP BETWEEN MAX.
INSIDE BTTM RAIL
OUTSIDE BTTM RAIL
OPENINGS SHALL NOT ALLOW
PASSAGE OF 4" BALL
DECKING
SIMPSON DTT2Z LATERAL
CONNECTOR
1/2"Q1 MACHINE BOLTS OR
THREADED RODS W/NUTS AND
WASHERS
2 x RIM BD.
2 x JOIST
SCALE 1 1/2" = 1'- 0"
ALTERNATE ATTACHMENT OF
HOLD-DOWN ANCHORS TO
FRAMING MEMBERS ARE
POSSIBLE PER SIMPSON
INSTRUCTIONS
2xJOIST
DOUBLE Q2x RIM DB
4 x 4 GUARD POST
2 x JOIST
SIMPSON DTT2 LATERAL
CONNECTOR
GUARDPOST TO RIM JOIST CONNECTION
��
SCALE 1 1/2" = 1'- 0"
P.Tt BEAM PER PLAN
SIMPSON ECC44 / ECC66 BASED
ON BEAM &COLUMN SIZE
3/8" THRU-BOLT W/ WASHERS
TOP &BOTTOM
4 x 4 P.T. KNEE -BRACE
4 x 4 KNEE -BRACE BEHIND POST
SHOWN DASHED
3/8" THRU-BOLT W/ WASHERS
EA. SIDE
P.T. POST PER PLAN
C
M
N
GUARDRAIL TYP. ELEVATION VIEW
7
1 ' -0"
TYP. DECK STAIRS
2 x 6 WD.CAP
CONNECT RAILINGS TO POSTW/
(2) #10 x 3" SCREWS
4 x 4 GUARD POST
2 x 2 VERTICAL BALUSTER
5 1/4" OC MAX.
OPENINGS SHALL NOT ALLOW
PASSAGE OF 4" BALL
2 x 4 OUTSIDE BTTM RAIL
DECKING
CONNECT BTTM RAILINGS TO
POST &BALUSTER W/ (2) #10 x
3" SCREWS
OPENINGS SHALL NOT ALLOW
PASSAGE OF 4" BALL
(2) 1 /2"Q1 MACHINE BOLTS OR
THREADED RODS W/NUTS AND
WASHERS
2 x RIM BD.
SCALE 1" = 1'- 0"
2 x 6 WD.CAP
1 1/2" O HANDRAIL PER CODE,
RETURN TO POST
4 x 4 GUARD POST
2 x 2 VERTICAL BALUSTER
5 1/4" OC MAX.
OPENINGS SHALL NOT ALLOW
PASSAGE OF 4" BALL
2 x 4 OUTSIDE BTTM RAIL
CONNECT BTTM RAILINGS TO
POST &BALUSTER W/ (2) #10 x
3"SCREWS
DECKING (2 x 4, 2 x 6, or 5/4)
2 X P.T. JOIST
LUS28
LS50
2 x P.T. RIM BD.
(2) 1/2"O MACHINE BOLTS OR
THREADED RODS W/NUTS AND
WSHRS @POST TO STRING.
OPENINGS AT STAIR RISER
SHALL NOT ALLOW PASSAGE
OF 6" BALL
2 x 12 P.T. STRINGER C� 18" OC
MAX
2 x 8 P.T. PLATE SECURED TO
CONC. FTG. W/ A.B., 1/2" O
BOLTS W/ APPR. EXPANSION,
EPDXY OR ADHESIVE ANCHORS
W/ WASHERS. EMBED. PER
MANUF. INSTRUCT.
CONC. FOOTING WIDTH OF STAIR
YiIJCYi: / :i/4 IVIHJC. hltllal-I I Jh1HLL IVV I UtVIHI t rl-SVIVI VIVt HIVV I tFi tiY IVIVFit I h1HIV �i/t5
TREAD RUN: 10" MIN.
NOSING: 3/4" - 1 1/4" NOSING SHALL NOT DEVIATE FROM ONE ANOTHER BY MORE THAN 3/8"
Span Table and Footing Schedule for Decks
Spans and footings assume the ma[imum 2_ cantilever using +em_)ir_'oug )ir 10. 2 or Eetter framing IumEer.
TaEle uses 70 p.s.f. loading (10 p.s.f. dead load _ 60 p.s.f live load) and 2000 p.s.f. soil Eearing pressure.
Joist
Slze
Joist
Spacing
Max. Joist
Span
Girder Beam Size and
Max. Span Between Support Posts /Footing Type
4x6
Footing
4x8
Footing
4x10
Footing
4xi2
Footing
12" o.c.
'-
'-u"
i xi
'-
i6x16
'-6"
t8x18
lt'-t"
T8xi8
2x6
i6" o.c.
6'-
'-u"
i xi
'-
16xi6
'-6"
18xi8
ii'-1"
i8x18
II2
" o.c.
'-
6'-
t xi
8'-
t6x16
u'-o"
t8x18
12'-io"
T8xT8
t2" o.c.
'- "
'-tt"
t xi
6'-6"
t6xt6
8'- "
t8xt8
io'-o"
2ox2o
2x8
i6" o.c.
8'-8"
'-ii"
i xi
6'-6"
16xi6
8'-
18xi8
io'-o"
i8xi8
II
2 " o.c.
-
'-u"
i xi
-
16xi6
'-6"
18xi8
1i'-i"
i8xi8
12" o.c.
i '-
'-6"
i xi
'=8"
i6x16
'-11"
i8xi8
'-2"
T8xi8
II 2xio
i6" o.c.
u'-6"
'-i"
i xi
16x16
6'-ii"
18xi8
8'-
2ox2o
2 " o.c.
-
'-u"
i xi
6'-6"
16x16
8'- "
i8xi8
io'-o"
2ox2o
�I
t2" o.c.
i '-
'-i"
i xi
'-i"
i6xt6
'-2"
i6xi6
6'-
i8xi8
II 2xi2
��
t6 o.c.
� ��
t -
-6'
t xi
� ��
-8
i6x16
�
-11"
t8x18
� ��
-2
t8x18
II2
" o.c.
io'-u"
'-i"
i xi
'- "
i6x16
6'-u"
i8x18
8'- "
i8x18
Footings must have a minimum reinforcment of (2) #4 bars each way with a 3" clearance to the bottom of the footing.
Note: Footing sizes are based on decks designed with single span joists where there is no center bearing beam.
Deck Ledger Connection to Band Joist a, b
(Reference IRC Table R5o7.2 -Deck live load = 6o psf, deck dead load = io psf, snow load <_ 4o psf)
For SI: i inch = 2�.a mm. i foot = �oa.8 mm. i Hound Her square foot = o.oa�4 kPa.
Joist Span
6' and less
6'i" to 8'
8'i" to io'
io'i" to 12'
12'1" to i4'
i4'i" to i6'
i6'i" to i8'
Connection Details
On -center spacing of fasteners
1/z inch diameter lag screw with 1/z
8
'7
inch maximum sheathin c,d
22
16
13
11
9
1/z inch diameter bolt with i/z inch
maximum sheathin d
go
22
18
15
13
ii
to
1/z inch diameter bolt with i inch
maximum sheathin e
26
19
16
13
11
l0
9
a. Ledgers shall be flashed in accordance with Section R7o3.4 to prevent water from contacting the house band joist.
b. Snow load shall not be assumed to act concurrently with live load.
c. The tip of the lag screw shall fully extend beyond the inside face of the band joist.
d . Sheathing shall be wood structural panel or solid sawn lumber.
e. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber or foam sheathing. Up
to t/2-inch thickness of stacked washers shall be permitted to substitute for up to 1/z-inch of allowable sheathing
thickness where combined with wood structural panel or lumber sheathing.
DECK NOTES
PRESSURE TREATMENT
ALL LUMBER SHALL BE GRADE #2 DOUGLAS-FIR, HEM -FIR, OR BETTER AND SHALL BE PRESSURE TREATED (TO RESIST INSECT AND DRY
ROT) IN ACCORDANCE WITH AMERICAN WOOD -PRESERVERS' ASSOCIATION STANDARDS (CATEGORY). DECK SURFACE AND TRIM
MATERIAL OF REDWOOD, CEDAR, OR OTHER WOOD WITH A NATURAL RESISTANCE TO DECAY DOES NOT REQUIRE PRESSURE
TREATMENT. THE LEVEL OF TREATMENT DEPENDS ON THE USE AS FOLLOWS:
1). DECKING MATERIAL, RAILINGS, JOISTS, AND BEAMS MUST BE TREATED TO A CATEGORY UC3B (OR MUST BE OTHER WOOD WITH A
NATURAL RESISTANCE TO DECAY).
2). POSTS AND OTHER WOODS LOCATED ON, IN, OR IN CONTACT WITH THE GROUND MUST BE A CATEGORY UC4B.
3). ANY WOOD LESS THAN SIX INCHES ABOVE THE GROUND OR IN CONTACT WITH CONCRETE MUST BE A CATEGORY UC4A.
WITH ALL NEW CUTS, TREAT THE CUT END OF THE WOOD WITH APAINT-ON PRESERVATIVE.
DECKING
ALL DECKING MATERIAL SHALL BE 2X4, 2X6, OR FIVE QUARTER (5/4") BOARDS. ATTACH DECKING TO EACH JOIST WITH TWO 10D NAILS
OR TWO #8 SCREWS. DECKING MAY BE PLACED FROM AN ANGLE PERPENDICULAR TO THE JOISTS TO AN ANGLE OF 45 DEGREES TO THE
JOISTS. DECKING MUST HAVE A SPAN LENGTH SUCH THAT EACH BOARD BEARS ON A MINIMUM OF TWO JOISTS.
HARDWOOD AND PLASTIC OR COMPOSITE DECKING PRODUCTS MAY BE SUBSTITUTED FOR CONVENTIONAL WOOD DECKING, BUT
INSTALLATION AND SPAN LENGTHS OF THE SUBSTITUTED MATERIAL MUST BE IN STRICT CONFORMANCE WITH THE PRODUCT LISTING
AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. COPIES OF THE MANUFACTURER'S INSTALLATION INSTRUCTIONS MUST BE
SUBMITTED WITH THE BUILDING PERMIT APPLICATION.
FASTENERS
ALL SCREWS AND NAILS SHALL BE HOT -DIPPED GALVANIZED OR STAINLESS STEEL. ALL HARDWARE (BOLTS, NUTS AND WASHERS, JOIST
HANGERS, MECHANICAL FASTENERS, HOEDOWNS, TIE PLATES CAST -IN -PLACE POST ANCHORS, ETC.) SHALL BE GALVANIZED WITH 1.85
OZ/SF OF ZINC (G-185 COATING) OR SHALL BE STAINLESS STEEL. LOOK FOR PRODUCTS SUCH AS "ZMAX" FROM SIMPSON STRONG -TIE
OR "TRIPLE ZINC" FROM USP.
FOOTINGS
THE BOTTOM OF ALL FOOTINGS FOR DECKS THAT ARE ATTACHED TO A HOUSE ARE TO BE PLACED A MINIMUM OF 18 INCHES BELOW THE
SURFACE OF THE FINISHED GRADE AND MUST BEAR ON FIRM, UNDISTURBED NATIVE SOIL. THE BOTTOM OF FOOTINGS FOR
FREESTANDING DECKS MAY BE AT ANY DEPTH ON UNDISTURBED NATIVE SOIL. FOOTINGS ADJACENT TO THE TOP OF A RETAINING WALL
MUST BE SET BACK FROM THE WALL A DISTANCE EQUAL TO THE HEIGHT OF THE WALL, OR BE EXTEND BELOW GRADE AN AMOUNT
EQUAL TO THE HEIGHT OF THE RETAINING WALL.
HEADERS
HEADERS OVER EXISTING DOORS, WINDOWS OR OPENINGS GREATER THAN SIX FEET IN WIDTH THAT ARE LOCATED BELOW A DECK THAT
WILL BE ATTACHED TO THE HOUSE MUST BE CHECKED TO VERIFY THAT THOSE HEADERS CAN SUPPORT THE ADDITIONAL LOAD ADDED
BY THE DECK.
LEDGER BOARD
DECKS THAT ARE ATTACHED TO A HOUSE REQUIRE A LEDGER BOARD TO BE FASTENED TO THE HOUSE STRUCTURE, AND THE DECK
JOISTS ARE FASTENED TO THE LEDGER.
SIDING AND FLASHINGS
THE SIDING OR EXTERIOR FINISH SYSTEM MUST BE REMOVED TO INSTALL THE LEDGER BOARD AGAINST THE WALL SHEATHING.
TWO LAYERS OF CONTINUOUS FLASHING MUST BE PROPERLY INSTALLED TO PREVENT WATER FROM GETTING INTO THE WALL WHERE
THE SIDING HAS BEEN REMOVED. THE FLASHING MATERIAL MAY BE COPPER (USING COPPER NAILS), STAINLESS STEEL, GALVANIZED
STEEL COATED WITH 1.85 OZ/SF OF ZINC (G-185 COATING), UV -RESISTANT PLASTIC, OR SELF-SEALING BITUMINOUS (TAR)
"PEEL -AND -STICK" FLASHING. THE FIRST LAYER IS ATTACHED DIRECTLY TO THE EXTERIOR WALL SHEATHING STARTING BEHIND AND
ABOVE THE BOTTOM EDGE OF THE BUILDING PAPER AND SIDING, CONTINUING STRAIGHT DOWN THE FACE OF THE WALL BEHIND THE
LEDGER BOARD (BEFORE IT IS INSTALLED) AND ENDING ON THE OUTER FACE OF THE EXTERIOR WALL SIDING OR FOUNDATION BELOW
THE BOTTOM OF THE LEDGER BOARD.
SELF-SEALING BITUMINOUS PEEL -AND -STICK FLASHING IS IDEAL FOR THE FIRST LAYER
PRE -FORMED Z-SHAPED METAL FLASHING IS IDEAL FOR THE OUTER, SECOND LAYER OF FLASHING. IT IS INSTALLED AFTER THE LEDGER
BOARD AND BEFORE THE JOISTS, STARTING BEHIND AND ABOVE THE BOTTOM EDGE OF THE BUILDING PAPER AND SIDING, CONTINUING
DOWN VERTICALLY TO THE TOP OF THE LEDGER BOARD, BENDING HORIZONTALLY TO THE OUTER FACE OF THE LEDGER BOARD, AND
BENDING AGAIN VERTICALLY DOWN THE FACE OF THE LEDGER BOARD AT LEAST 1/2".
LEDGER BOARD FASTENERS
ALL FASTENERS SHALL BE SPACED PER THE TABLES PROVIDED WITH FIGURES 5, 6, 7 AND 8 AND SHALL BE INSTALLED PER FIGURE 12.
ALL FASTENERS SHALL BE INSTALLED WITH WASHERS AND THOROUGHLY TIGHTENED.
THRU-BOLTS: THRU-BOLTS ARE THOSE WHERE A HOLE IS DRILLED ALL THE WAY THROUGH THE WOOD MEMBERS AND A NUT AND
WASHER ARE ATTACHED TO COMPLETE THE CONNECTION. THRU-BOLTS SHALL HAVE A MINIMUM DIAMETER OF ?". LEAD (PILOT) HOLES
FOR THRUBOLTS SHALL BE 17/32" TO 9/16" IN DIAMETER. THRU-BOLTS MUST BE EQUIPPED WITH WASHERS AT THE BOLT HEAD AS WELL
AS THE NUT.
EXPANSION (WEDGE) ANCHORS: USE EXPANSION ANCHORS WHEN ATTACHING A LEDGER BOARD TO A CONCRETE WALL
BOLT DIAMETERS OF THE ANCHORS SHALL BE A MINIMUM OF 1/2"; IN SOME CASES, THIS MAY REQUIRE AN ANCHOR SIZE OF 5/8".
MINIMUM EMBEDMENT LENGTH SHALL BE 21/2". EXPANSION ANCHORS MUST HAVE WASHERS. EXPANSION ANCHORS MUST BE
INSTALLED AS REQUIRED BY THE MANUFACTURER'S INSTRUCTIONS. THIS MAY INCLUDE CLEANING THE HOLES DRILLED IN THE
CONCRETE TO ENSURE THEY ARE FREE OF DIRT, DEBRIS, AND MOISTURE. IMPROPER INSTALLATION OF THE ANCHORS CAN RESULT IN
CATASTROPHIC FAILURE AND COLLAPSE OF THE DECK.
ADHESIVE ANCHORS: ADHESIVE ANCHORS MAY BE USED IN PLACE OF EXPANSION ANCHORS WITH A DESIGN BY A LICENSED
STRUCTURAL ENGINEER. SPECIAL INSPECTIONS ARE REQUIRED FOR EXPANSION ANCHORS AND ADHESIVE ANCHORS. THEY ARE
PERFORMED BY THIRD -PARTY INSPECTORS THAT ARE HIRED BY THE PROJECT OWNER. THE SPECIAL INSPECTOR VERIFIES THAT THE
EXPANSION OR ADHESIVE FASTENERS ARE INSTALLED CORRECTLY AND SUBMITS A REPORT TO THE OWNER AND THE CITY.
LAG SCREWS: LAG SCREWS SHALL HAVE A DIAMETER OF 3/8" AND SHALL BE HOT -DIPPED GALVANIZED OR STAINLESS STEEL ONLY. ALL
LAG SCREWS SHALL BE INSTALLED WITH WASHERS. SCREW MUST PENETRATE BEYOND AND BOARD/RIM JOIST A MINIMUM OF 1 /2"
LAG SCREW INSTALLATION REQUIREMENTS: EACH LAG SCREW SHALL HAVE LEAD (PILOT) HOLES DRILLED AS FOLLOWS: 1) DRILL A 3/8"
DIAMETER HOLE IN THE LEDGER BOARD, 2) DRILL A 3/16" DIAMETER HOLE INTO THE SOLID CONNECTION MATERIAL OF THE EXISTING
HOUSE. DO NOT DRILL A 3/8" DIAMETER HOLE INTO THE SOLID CONNECTION MATERIAL.
THE THREADED PORTION OF THE LAG SCREW SHALL BE INSERTED INTO THE LEAD HOLE BY TURNING. DO NOT DRIVE WITH A HAMMER.
USE SOAP OR AWOOD-COMPATIBLE LUBRICANT AS REQUIRED TO HELP FACILITATE TIGHTENING. EACH LAG SCREW SHALL BE
THOROUGHLY TIGHTENED.
GUARDRAILS
DECKS AND STAIRWAYS MORE THAN 30 INCHES ABOVE THE ADJACENT GRADE MUST HAVE GUARDRAILS. THE GUARDRAIL MUST BE
DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS, IN ANY DIRECTION ANYWHERE ALONG ITS LENGTH, AND THE INFILL
AREA MUST WITHSTAND A LOAD OF 50 POUNDS PER SQUARE FOOT AREA.
STAIR HANDRAILS
STAIRS WITH FOUR OR MORE RISERS MUST HAVE A HANDRAIL ON AT LEAST ONE SIDE. HANDRAILS SHALL BE GRASPABLE AND SHALL BE
OF DECAY -RESISTANT AND/OR CORROSION -RESISTANT MATERIAL. THE HAND GRIP PORTION, IF CIRCULAR, SHALL BE BETWEEN 11/2"
AND 2" IN CROSS SECTION. SHAPES OTHER THAN CIRCULAR SHALL HAVE A PERIMETER DIMENSION BETWEEN 4" AND NOT GREATER
THAN 6 1/4" WITH A MAXIMUM CROSS SECTIONAL DIMENSION OF 2 1/4". ALL SHAPES MUST HAVE A SMOOTH SURFACE WITH NO SHARP
CORNERS. HANDRAILS SHALL RUN CONTINUOUSLY FROM A POINT DIRECTLY ABOVE THE LOWEST RISER TO A POINT DIRECTLY ABOVE
THE HIGHEST RISER AND SHALL RETURN TO THE GUARD AT EACH END. HANDRAILS MAY BE INTERRUPTED AT GUARDRAIL POSTS ONLY
AT A TURN IN THE STAIR.
STAIR HANDRAILS
STAIRS WITH FOUR OR MORE RISERS MUST HAVE A HANDRAIL ON AT LEAST ONE SIDE. HANDRAILS SHALL BE GRASPABLE AND SHALL BE
OF DECAY -RESISTANT AND/OR CORROSION -RESISTANT MATERIAL. THE HAND GRIP PORTION, IF CIRCULAR, SHALL BE BETWEEN 11/4"
AND 2" IN CROSS SECTION. SHAPES OTHER THAN CIRCULAR SHALL HAVE A PERIMETER DIMENSION BETWEEN 4" AND NOT GREATER
THAN 61/4" WITH A MAXIMUM CROSS SECTIONAL DIMENSION OF 21/4". ALL SHAPES MUST HAVE A SMOOTH SURFACE WITH NO SHARP
CORNERS. HANDRAILS SHALL RUN CONTINUOUSLY FROM A POINT DIRECTLY ABOVE THE LOWEST RISER TO A POINT DIRECTLY ABOVE
THE HIGHEST RISER AND SHALL RETURN TO THE GUARD AT EACH END. HANDRAILS MAY BE INTERRUPTED AT GUARDRAIL POSTS ONLY
AT A TURN IN THE STAIR.
RESUB
Sep 16 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
w � �
}Z
mo
w ~ �
3=
�U�O¢
w �
w3
� Q \
V
�
O
��
m
0° a
CV
u~i
�
�
V
w
0
w
J
J
W
W
m
Revisions
No.
#1 Submit
#2
#3
#4
#5
3 � .ri
� N �
> o
C W N
m
C I�
3 �
u,
� � N
M C V
a
o E
E
0
C
3
0
m
■
Date
8/19/2021
9/14/2021
Drawn by: BEO
Checked by: BEO
GENERAL DETAILS
Drawing:
BELOW DECK KNEE BRACE (when required)
SCALE 1" = 1'- 0"
CORNER POST KNEE BRACE (when required)
SCALE 1" = 1'- 0"
A3.1