APPROVED BLD-BLD2022-0820+Architectural_Plan+6.23.2022_8.05.21_AM+2949562EXISTING/DEMO FIRST FLOORPLAN 1V SCALE: 1/4" = 1'-0" 28'-7 7/8" ATTIC CLG HT: 51 1/2" O G�+J OFFICE m CLG HT: 107" cCDv l�l - BATHROOM— CLG H BEDROOMI BEDROOM 2 = c-, CLG HT: 107" CLG HT: 107" m T-1 1/4" 8'-5 5/8" T-11 1/8" 28'-11 3/4" EXISTING/DEMO SECOND FLOORPLAN SCALE: 1/4" = V-0" PROJECT INFORMATION: VICINITY MAP: 6924 176th St SW GENERAL NOTES: 1. All work to comply with 2018 International Building Code and PROJECT CONTACT: Selena Fitch 2018 international Residential Code with local amendments. Fitch Design Company 2. Verify all dimensions and field conditions before beginning work 425-481-8190 and notify designer of any discrepancies. Selena@FitchDesignCompany.com 1761h St SW 3. Provide solid wood blocking for support at all wall mounted fixtures. 176th St Sw 176th OWNER: Catherine A Dominguez & Kenneth R Chink 4. Provide approved draftstopping in concealed space between 6924 176th St SW, ceiling and floor; and approved firestopping in walls per code. Edmonds 98026 S. Flash all openings with minimum 26 gauge steel (galvanized or factory finish). PARCEL NUMBER: 00513100015411 6. All wood in contact with concrete or masonry to be pressure treated. LIFE SAFETY NOTES: JURISDICTION: EDMONDS 1. Stairways to meet minimum requirements of 2018 IRC R311.7; cr - Minimum stair width: 36" SCOPE OF WORK: BATHROOM REMODEL, NON ZT - Minimum headroom: 80" LOAD BEARING WALLS TO -Maximum riser height: 7 3/4" BE REMOVED 6924 176th St Sal, - Minimum tread depth: 10" Edmonds, NA 96026 - Rise or run dimensions shall not vary more than 3/8" 1:5 min driti-e ­i�ork - Minimum landing length: 36" - Handrail height: 34-38" above stair nosing 2. Stairways with four or more risers shall have a handrail. 3. Handrails shall be continuous and terminate at a wall or newel post. 4. Guards shall be provided for porches, balconies or raised floor DISCLOSURE: surfaces located more than 30" above the floor or grade below. ALL DIMENSIONS & SIZE DESIGNATIONS GIVEN S. Guards shall be 36" in height and designed to resist a 200 lb. ARE SUBJECT TO VERIFICATION ON JOBSITE & concentrated load on the top rail and 50 psf on all guardrail ADJUSTMENT TO FIT UNFORESEEN JOB infill components. CONDITIONS. DESIGN PLANS ARE NOT PROVIDED 6. Required guards shall have a maximum opening such that a 4" FOR ARCHITECTURAL OR ENGINEERING USE. diameter sphere can not pass through. 11'-8 7/8" 7. All new smoke and carbon monoxide detectors to be hardwired with a battery back-up. ENERGY NOTES: 1. All new fenestration U-values and insulation R-values shall satisfy the prescriptive path of the 2018 Washington State Energy Code. 2. Prescriptive Requirements (Climate zone 4C); - Vertical glazing: U = 0.30 - Overhead glazing: U = 0.50 - Doors: U = 0.20 - Ceilings: R-49 - Single rafter ceilings: R-38 - Walls (above grade): R-21 (w/ headers insulated R-10) - Walls (below grade): 10/15/21 int +TB - Floors: R-30 - Slab on grade: R-10 (24" perimeter) 3. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation shall not be less than specified above. 4. Builder shall complete and post an insulation "Certificate for Residential Construction" within three feet of the electrical panel prior to final inspection. S. Blower door testing: air leakage shall not exceed three air changes per hour. A written report of blower door test results shall be signed by the testing party and provided to the building inspector prior to call for final inspection. 6. A minimum of 75% of permanantly installed lamps in lighting fixtures shall be high efficacy lamps. 7. Kitchen, Bathroom and Laundry exhaust fans shall terminate outdoors and not in attics, soffits, ridge vents or crawl spaces. 8. A whole house mechanical ventilation system shall be designed in accordance with IRC section M1507.3. The ventilation system shall provide outdoor air at a rate not less than specified in tables M1507.3.3(1) or MlS07.3.3(2). WALL LEGEND - NEW FRAMED WALLS 0 EXISTING WALLS REMOVE EXISTING INTERIOR NOTES DIMENSIONS ARE FROM FINISHED DRYWALL TO FINISHED DRYWALL, UNLESS NOTED OTHERWISE ALL DRAWINGS & NOTES CROSS-REFERENCE EACH OTHER. SEE SPECIFICATION SHEETS FOR ADDITIONAL SPEC'D PRODUCT INFORMATION. CABINET DETAILS & DIMENSIONS ARE SUBJECT TO VARIATION BASED ON ON -SITE FRAMING & CABINET MANUFACTURER & MAY VARY FROM DRAWINGS. - CABINET SUPPLIER TO VERIFY ACTUAL THICKNESS OF SELECTED SLAB COUNTERTOPS IN RELATION TO CABINET HEIGHTS, ADJUST AS NEEDED (SELECTIONS MAY VARY FROM DRAWINGS & SPECS) RECOMMENDATION: A CABINET CONTROL SAMPLE SHOULD BE SEEN AND APPROVED BY CLIENT PRIOR TO CABINET ORDER - ALL NATURAL STONE (TILE & SLABS) CAN VARY FROM SAMPLES USED IN THE DESIGN PROCESS. IT IS STRONGLY RECOMMENDED THAT CLIENTS SEE AND APPROVE ACTUAL SLABS PRIOR TO FABRICATION. TILE LAYOUTS CAN VARY FROM DRAWINGS BASED ON ON -SITE CONDITIONS FIELD VERIFY ALL SHWR PLUMBING HEIGHTS & BATHROOM ACCESSORY LOCATIONS W/ HOMEOWNER PRIOR TO INSTALLATION PAGE REFERENCE: 1.0-EXISTING FLOOR PLANS 2.0-NEW FLOOR PLANS 0 1 2 3 4 5 FIXED SCALE 1 TO 1 IN FT. Z V w 0 2 VL r LL Z a CL 2 0 U E DATE: 06/17/2022 JOB NO. 552 �o O N Q 1.0 W z a 0 0 w w 0 w Q c� z E Cn x w 100 ALL DIMENSIONS & SIZE DESIGNATIONS GIVEN ARE SUBJECT TO VERIFICATION ON JOBSITE & ADJUSTMENT TO FIT UNFORESEEN JOB CONDITIONS. DESIGN PLANS ARE NOT PROVIDED FOR ARCHITECTURAL OR ENGINEERING USE. WALL LEGEND Z V Ul? W Z - NEW FRAMED WALLS Q CL EXISTING WALLS T 2 REMOVE EXISTING i o V " H LL INTERIOR NOTES • DIMENSIONS ARE FROM FINISHED DRYWALL TO FINISHED DRYWALL, UNLESS NOTED OTHERWISE • ALL DRAWINGS & NOTES CROSS-REFERENCE EACH OTHER. SEE SPECIFICATION SHEETS FOR ADDITIONAL SPEC'D PRODUCT INFORMATION. • CABINET DETAILS & DIMENSIONS ARE SUBJECT TO VARIATION BASED ON ON -SITE FRAMING & CABINET MANUFACTURER & MAY VARY FROM E DRAWINGS. c� • CABINET SUPPLIER TO VERIFY ACTUAL THICKNESS OF SELECTED SLAB ¢ COUNTERTOPS IN RELATION TO CABINET E HEIGHTS, ADJUST AS NEEDED (SELECTIONS MAY VARY FROM pp DRAWINGS & SPECS) w • RECOMMENDATION: A CABINET 0�0 u Q CD ON CONTROL SAMPLE SHOULD BE SEEN AND A a APPROVED BY CLIENT PRIOR TO CABINET w w CO ORDER CZ7 C,5 00 39'-1" ALL NATURAL STONE (TILE & SLABS) CAN VARY FROM SAMPLES USED IN THE A cn cn dN DESIGN PROCESS. IT IS STRONGLY 28'-7 7/8" RECOMMENDED THAT CLIENTS SEE AND APPROVE ACTUAL SLABS PRIOR TO DATE: 9'-7" 16-3 3/4" 12'-2 1/4" FABRICATION. 06/17/2022 • TILE LAYOUTS CAN VARY FROM 20'-5 1/4" 8'-2 5/8" DRAWINGS BASED ON ON -SITE JOB NO. CONDITIONS 552 • FIELD VERIFY ALL SHWR PLUMBING HEIGHTS & BATHROOM ACCESSORY LOCATIONS W/ HOMEOWNER PRIOR TO INSTALLATION PAGE REFERENCE: 0 ATTIC