APPROVED BLD BLD2022-1177+Architectural_Plan+9.2.2022_1.15.23_PM+3088727J GENERAL REQUIREMENTS REFER TO SUBSEQUENT PLAN AND DETAIL NOTES FOR VARIATIONS AND REQUIREMENTS SPECIFIC TO REFERENCED PROJECT. NOTES ON DRAWINGS TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES. DESIGN CRITERIA BUILDING CODE CONFORMANCE (MEETS OR EXCEEDS REQUIREMENTS): 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 WASHINGTON BUILDING CODE 2018 WASHINGTON RESIDENTIAL CODE DEAD LOADS: ROOF DEAD LOAD 15 PSF FLOOR DEAD LOAD 15 PSF WOOD WALL DEAD LOAD 12 PSF INTERIOR WALL DEAD LOAD 9 PSF CONCRETE 150 PCF LIVE LOADS: ROOF SNOW LOAD 25 PSF FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF PUSH PIERS/PIN PILE MATERIALS: BRACKET PLATES - ASTM A36 (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) PIER TUBES - ASTM A500 GRADE B OR C (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 55 KSI) EXTERNAL SLEEVE - ASTM A500 GRADE B OR C (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 62 KSI) PIER CAP - ASTM A529 GRADE 50 (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 65 KSI) COIL ROD - ASTM A193 GRADE B7 (MIN YIELD STRESS, Fy = 105 KSI / MIN TENSILE STRESS, Fu = 125 KSI) STEEL ANGLE SHAPES - ASTM A36 (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) SHAFT COUPLER - ASTM A513 TYPE 5 (MIN YIELD STRESS, Fy = 70 KSI / MIN TENSILE STRESS, Fu = 87 KSI) SHAFT COUPLING HARDWARE - GRADE 8 BOLTS WITH NUTS HELIX PLATES - ASTM A572 GRADE 50 (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 65 KSI) WELDING NOTES: CONFORM TO AWS D1.1. WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH AWS REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. CORROSION PROTECTION: SACRIFICIAL DESIGN THICKNESS - CAPACITIES INCLUDE A SCHEDULED LOSS IN STEEL THICKNESS DUE TO CORROSION FOR BLACK, UNCOATED STEEL. ANCHORS ARE DESIGNED FOR 50-YEAR SCHEDULED SACRIFICIAL THICKNESS LOSS IN ACCORDANCE WITH ICC-ES AC358. PUSH PIER & PIN PILE SPLICING: PILES ARE TO BE GRAVITY SPLICED WITH FITTING COUPLERS. BUILDING WEIGHT WILL ENSURE JOINTS DO NOT SEPARATE. EXISTING UTILITY LINES: CONTRACTOR TO REPAIR UTILITY LINES THAT MAY BE DAMAGED DURING INSTALLATION PUSH PIERS/HELICAL TIEBACKS/PIN PILE (CONT. INSTALLATION: SYSTEMS TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MINIMUM INSTALLATION PRESSURE IS TO BE DETERMINED BY THE FOLLOWING EQUATION: • PUSH PIER INSTALLATION PRESSURE (PSI): [DESIGN WORKING LOAD] X [FS = 2] / [HYDRAULIC RAM AREA] MINIMUM INSTALLATION DEPTH IS 10'-O" f UNO. • PIN PILES ARE TO BE DRIVEN TO REFUSAL. INSTALLATION REFUSAL IS CONSIDERED TO BE REACHED WHEN THE ENERGY FROM A 150 LB PNUEUMATIC HAMMER NO LONGER CARRIES A VERTICAL DISPLACEMENT OF ONE INCH MOVEMENT OBSERVED IN A ONE MINUTE TIME SPAN TO THE PILE. MINIMUM INSTALLATION DEPTH IS 10'-O" t UNO. NOTIFY ENGINEER IF MINIMUM INSTALLATION CONDITIONS CANNOT BE ACHIEVED. .STING & INSPECTION EXPIRES: 04/04/24 CONTINUOUS SPECIAL INSPECTIC, IS REQUIRED DURING INSTALLATION PER 2018 IBC SECTION 1810.4.12. THE SPECIAL INSPECTOR IS RESPONSIBLE FOR VERIFYING AND RECORDING THE FOLLOWING: • PROJECT DESCRIPTION (ADDRESS, INSTALLATION DATE, PERMIT NUMBER • PILE AND BRACKET CONFIGURATION • PART DESCRIPTION (PRODUCT MANUFACTURER, BRACKET TYPE, PIER TYPE, PIER OUTSIDE DIAMETER, PIER WALL THICKNESS) • PIER INCLINATION, LOCATION, DEPTH, AND INSTALLATION PRESSURE ACHIEVED LOAD TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM METHOD D1143 (QUICK METHOD) ON 20 PERCENT OF PIERS AND WILL BE SELECTED BY THE SPECIAL INSPECTOR. AN ALIGNMENT LOAD (AL) SHALL BE APPLIED TO THE PILE PRIOR TO SETTING THE DEFLECTION MEASURING EQUIPMENT TO ZERO OR A REFERENCE POSITION. THE AL SHALL BE NO MORE THAN 10% OF THE DESIGN LOAD. INCREMENTAL LOADING SHALL BE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE. TEST LOADING SCHEDULE AL (.10 DL MAX) 0.25 DL 0.50 DL 0.75 DL 1.00 DL 1.25 DL 1.50 DL 1.25 DL 1.00 DL 0.75 DL 0.50 DL 0.25 DL HOLD TIME 0 MIN. UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE HOLD FOR CREEP TEST (SEE BELOW) UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE MAX DEFLECTION City Of Edmon s Building Department Work FOUNDATION STABILIZAT N Address r 8526 216TH ST SW 0.04 Owner KIN -------------- --- ------------------------- Approved Date, -- 9/21/2022 Building Official /7vstav-asc - ---------- --- W. W Permit Number ------------- ---- BLD26 2-1177 LOAD TESTING CREEP ACCEPTANCE CRITERIA SHALL BE NO GREATER THAN 0.04 IN= 1=E---- PERIOD. IF MOVEMENT IS OBSERVED GREATER THAN 0.04 INCHES WITHIN THE 10 MINUTE PERIOD THE LOAD TEST SHALL BE HELD FOR AN ADDITIONAL 50 MINUTES, THE PIER IS TO BE DEEPENED AND RE -TESTED, OR THE PIER IS TO BE ABANDONED AND REPLACED WITH A NEW PIER. IF THE LOAD TEST IS TO BE HELD THE PIER MOVEMENTS SHALL BE MEASURED AT 15, 20, 30, 40, 50, AND 60 MINUTES. THE CREEP VERSUS THE LOGARITHM OF TIME SHALL BE PLOTTED. IF THE CREEP RATE IS LESS THAN 0.080 INCHES BETWEEN 6 AND 60 MINUTES, THE LOAD TEST SHALL BE CONSIDERED SUCCESSFUL. PUSH PIER TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / [AREA OF HYDRAULIC RAM]. (Special Inspections are required for this permit. ■Provide the Special Inspection Reports as (required in the Testing and Inspection notes i .found on sheet S1.1. This report is to be (provided to the City Building Inspector upon ■request. Please see clouded Special Inspections I �on this sheet. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ r ■■MIMI Welding to be completed by: ■ I WABO certified welder or welding shop that will be used on this project. 2"Sfeu SFA Design Group, LLL 11 PortlandR OR`I'Livermore,'CA (Seattle, WA WA50)91.8311 w .fadg. M 0 z_ z z_ O_ rr LLI 0 z LU w 0 W LLI lY LU z z_ 0 o Cn CD H rn cn Q c~o r) N Z N O LO CIO 0 w GENERAL NOTES REVISIONS PROJECT NO: M FR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 APPROVED PLANS MUST BE ALL WORK SUBJECT TO FIELD INSPECTION FOR RECEIVED SHEET NO: ON JOB SITE CODE COMPLIANCE Sep 06 2022 S1.1 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NCFI GEOTECHNICAL - TERRATHANE 24-010 POLYURETHANE FOAM TERRATHANE GEOTECHNICAL - 24-010 INSTALLATION SEQUENCE THE FOLLOWING INSTALLATION STEPS PROVIDE A BROAD OVERVIEW OF TERRATHANE GEOTECHNICAL 24-010 POLYURETHANE FOAM INJECTION BENEATH A CONCRETE SLAB OR PAVEMENT. INTERMEDIATE STEPS, INSTALLATION EQUIPMENT AND TOOLS USED, AND CONSIDERATIONS FOR UNUSUAL CONDITIONS OR APPLICATIONS ARE NOT ADDRESSED. STEP 1: ACCESS/APPLICATION HOLES ARE DRILLED (9/8"0) AT STRATEGIC LOCATIONS IN THE SLAB. IN GENERAL, THE HOLES ARE SPACED 5 FEET APART AND 3 FEET FROM THE EDGES OF THE SLAB. LOCATIONS AND SPACING ARE OFTEN MODIFIED IN THE FIELD TO ACHIEVE THE DESIRED RESULT. STEP 2: INJECTION PORTS ARE PLACED TO SEAL THE HOLES. STEP 3: TERRATHANE GEOTECHNICAL 24-010 POLYURETHANE FOAM IS INJECTED TO FILL VOIDS AND ALLOW FOR LIFTING. LIFT MAY BE MONITORED WITH SURVEY EQUIPMENT OR STRING LINES. STEP 4: THE INJECTION PORTS ARE REMOVED AND THE HOLES ARE PATCHED WITH MORTAR MIX, NEXUSPRO SILICONE JOINT SEALANT, OR EPDXY SEALANT. TERRATHANE GEOTECHNICAL 24-010 POLYURETHANE FOAMS ARE MOST OFTEN USED BENEATH EXTERIOR CONCRETE SIDEWALK AND PAVEMENT SECTIONS FOR STABILIZATION OR RELEVELING, BUT ARE ALSO UTILIZED FOR INTERIOR WORK AND OTHER SPECIALTY APPLICATIONS. TERRATHANE GEOTECHNICAL 24-010 POLYURETHANE FOAM IS OFTEN CONSIDERED AS AN ALTERNATIVE TO MUDJACKING OR REMOVAL AND REPLACEMENT. SETTLEMENT OF RESIDENTIAL SLABS IS TYPICALLY THE RESULT OF CONSOLIDATION OF POORLY COMPACTED FILL SOILS AROUND FOUNDATIONS AND WITHIN UTILITY TRENCHES, SOFTENING OF WEAK NATIVE SOILS AND FILL DUE TO INCREASES IN MOISTURE CONTENT, AND EROSION OR WASHOUT CONDITIONS RESULTING FROM POOR DRAINAGE. CRACKED SLABS, FAULTING BETWEEN SLAB SECTIONS, AND/OR OTHER OBVIOUS DOWNWARD VERTICAL MOVEMENT ARE TYPICALLY THE FIRST OBSERVABLE SYMPTOMS OF SETTLEMENT FROM THE SURFACE, THOUGH VOIDS MAY ALSO BE PRESENT BELOW AS RIGID SLABS CAN SPAN BETWEEN SUPPORT POINTS. WHEN VOIDS ARE PRESENT, USING INERT, HYDROPHOBIC TERRATHANE GEOTECHNICAL 24-010 POLYURETHANE FOAM ALLOWS FOR UNDERSEALING OF THE REGION, PREVENTING ANY FURTHER WASHOUT AND ACTING TO AGAIN PROVIDE UNIFORM SUPPORT TO THE BRIDGED CONCRETE. WHEN SLABS HAVE SETTLED, WITH OR WITHOUT THE PRESENCE OF VOIDS, FOAM CAN BE INJECTED TO CREATE LIFT WITHOUT ADDING SIGNIFICANT WEIGHT TO THE UNDERLYING SOIL. TERRATHANE GEOTECHNICAL 24-010 POLYURETHANE FOAM IS INSTALLED WITH CUSTOM-BUILT INSTALLATION RIGS AVAILABLE AS TRUCK -MOUNTED OR TRAILER UNITS. THE BASIC COMPONENTS OF THE SYSTEM INCLUDE MATERIAL STORAGE TANKS, A GENERATOR, AN AIR COMPRESSOR, PUMPS, A PROPORTIONER, AND APPLICATOR(S)/ GUN(S). THE PROPORTIONER INCLUDES A MATERIAL HEATER, PRESSURE REGULATOR, STROKE COUNTER, AND INSULATED AND HEATED HOSES. THIS ENSURES THAT THE TWO PARTS ARE DELIVERED TO THE APPLICATOR AT A CONSISTENT PRESSURE AND TEMPERATURE. TERRATHANE GEOTECHNICAL - 24-010 POLYURETHANE FOAM TABLES COMPONENT PROPERTIES COMPONENT B-24-010 A2-000 BROOKFIELD VISCOSITY AT 72°F 600 CPS AT 72°F 200 CPS AT 72°F SPECIFIC GRAVITY 1.08 1.24 WEIGHT PER GAL 8.9 LBS 10.3 LBS APPEARANCE CLEAR AMBER LIQUID CLEAR BROWN LIQUID STORAGE TEMPERATURE 60°-90°F 60°-90°F POLYURETHANE FOAM TABLES (CONT.) REACTIVITY AT 110°F CREAM TIME (SEC) 1 GEL TIME SEC 7 TACK FREE TIME SEC 12 RISE TIME SEC 17 PROCCESSING PARAMETERS ISO TEMPERATURE 100°-140°F POLY TEMPERATURE 110°-140°F MIXING PRESSURE STATIC 1000 PSI MIXING PRESSURE DYNAMIC 800 PSI MIX RATIO BY WEIGHT 100 PARTS POLY: 116 PARTS ISO BY VOLUME 100 PARTS POLY: 100 PARTS ISO NOTE: INSTALL PER MFR RECOMMENDATIONS EXPIRES: 04/04/24 PHYSICAL PROPERTIES PHYSICAL PROPERTIES TEST METHOD FREE RISE RESTRAINED DENSITY ASTM D1622 2.8 PCF 3.9 PCF COMPRESSIVE STRENGTH ASTM D1621 25.7 PSI 60.5 PSI COMPRESSIVE MODULUS ASTM D1621 695 PSI 1714 PSI TENSILE STRENGTH ASTM D1623 64.5 PSI 78 PSI TENSILE MODULUS ASTM D1623 96 PSI ------ WATER ABSORBTION ASTM D2842 < 0.08 Ib%tz < 0.08 Ib%tz CLOSED CELL CONTENT - - - - - - - > 90% > 90% MAX SERVICE TEMP - - - - - - - 180°F 180°F ELONGATION ASTM D1623 7.0% ------ SHEAR STRENGTH ASTM C273 38.7 PSI SHEAR MODULUS ASTM C273 486 PSI FLEXURAL STRENGTH ASTM D790 57.8 PSI ------ FLEXURAL MODULUS ASTM D790 1279 PSI ------ RECEIVED Sep 06 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SFA Design Group, LLL ` Po Il dRORIE Livermore,Livermore,CA I Seattle, WA p: (50)91.8311 w .fmg. m 0 z_ z Z_ W CI � z c"i � U) rn W U) Q U z U) W No co Lo c/) co C) W w Q W z z_ GENERAL NOTES If REVISIONS 1 PROJECT NO: M FR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 SHEET NO: S1.2 SAFEBASE STABILIZER SYSTEM INFO PART DESCRIPTION COMMENTS MIN YIELD STRESS, Fy MIN TENSILE STRESS, F„ R ASTM A36 R /2x6xO'-6" W/ (4) /g"0 HOLES W/ WELDED WOOD BEAM 36 KSI 58 KSI TOP 11/4"Ox11/2" IPS SCH 40 ASTM A53 PIPE CONDITION 30 KSI 48 KSI 11/40 —7x12" ASTM A193 GRADE B7 THREADED ROD W/ THREADED ROD 11/40"-7 ASTM A194 GRADE 2H HEX NUT 75 KSI 125 KSI HSS 4x4x3/16x0'-4" ASTM A500 GRADE B/C HD GALV PER ASTM 50 KSI 65 KSI THREADED CAP A123 W/ WELDED R3/4x4xO'-4" ASTM A36 & 11/4"0-7 ASTM 194 36 KSI 58 KSI GRADE 2H HEX NUT V/4x6x0'-6" ASTM A36 W/ (2) HOLES W/ WELDED HSS 36 KSI 58 KSI BASE 4x4x3/ xO'-2" ASTM 500 GRADE B/C HD GALV PER ASTM A123 50 KSI 65 KSI ASTM A36 BENT R /16x11/2Hx31/2WxO'-3 /g"L W/ WELDED 36 KSI 58 KSI BEAM CRADLE 11/4"Ox11/ " IPS SCH 40 ASTM A53 PIPE 30 KSI 48 KSI 3/16" HIGH DENSITY POLYETHYLENE SHELL (21 "SQ BASE) LIGHTFOOT 15 PCF POLYURETHANE (F'c=470-510 PSI) 3.375 KIPS MAX BASE 10 PCF POLYURETHANE (F'c=285-310 PSI) 3.5 PCF POLYURETHANE (F'c=55-60 PSI) ASTM A500, GRADE B/C HD GALV, PER ASTM A123 MAIN TUBE HSS 31/2x31/2x11GA 50 KSI 65 KSI NOTE: INSTALL PER MFR RECOMMENDATIONS N- i VICINITY MAP SCALE: NTS DO NOT PLACE PIERS THIS ZONE W 0 DIRECTIOI FROM ENGINEER \ / I �"L I L I i L T NO PIER PLACEMENT ZONE EXPIRES: 04/04/24 FHIS ZONE W/O DIRECTION FROM ENGINEER —CONTRACTOR TO NOTIFY FOR IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATION BRACKETS REC VJIL) 4ve- SCALE: NTS CITY O DMOND DEVELOPME ICES DEPARTMENT sfa 5FA Design Group, Lir Rortl . ORcI' Li,,Illle,fCA I Seattle, WA p: (503) 91.8311 w .fags z z z O_ rr L 0 N z � co L co Q CU � z U) L No Q NO U) co 0 L w rr rr Q L z Z_ GENERAL NOTES [REVISIONS 1 PROJECT NO: MFR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 DSHEET NO: S1.3 (E) FOUNDATION/(N) PIER/(N) FLR STABILIZER LAYOUT PLAN NOTES: 1. REFERENCE S1.1, S1.2 & S1.3 FOR GENERAL REQUIREMENTS 2. CONTRACTOR TO NOTIFY ENGINEER OF RECORD OF DISCREPANCIES BETWEEN FIELD CONDITIONS & THOSE SHOWN IN THESE DOCUMENTS PRIOR TO WORK TYP A 3• INDICATES (E) CONC STEMWALL ON (E) CONC FOOTING (CONTRACTOR TO VERIFY 6"Wx2'-0"H (E) CONC STEMWALL AND 1'-4"Wx8"DP (E) CONC FOOTING MIN TYP (NOTIFY ENGINEER OF RECORD IF FIELD CONDITIONS DIFFER IN THE AREA OF WORK)) 4 INDICATES WOOD WALL ON (E) CONC STEMWALL ON (E) CONC FOOTING (NOTIFY ENGINEER OF RECORD IF FIELD CONDITIONS DIFFER IN THE AREA OF WORK)) / 5• \ j INDICATES (N) POLYURETHANE BACKFILL PER DETAIL (\ 2/S4.3 ((1) TOTAL) 6. � X/SX.X SECTION CUT — DETAIL NUMBER/SHEET NUMBER 7• (I�U INDICATES LOCATION OF SAFEBASEMENT PUSH PIER SYSTEM W/ SAFEBASE—LD288 FOUNDATION BRACKET PER DETAILS ON S 4.1 ((10) TOTAL) PUSH PIER INSTALLATION NOTES: • MAX LOAD TO ANCHOR = 6,568 LBS • 2.875"0 PIPE PILE W/ 0.165" THICK WALL • 3.5"Ox36" LONG PIPE SLEEVE W/ 0.216" WALL • MINIMUM 10'-0" INSTALLATION DEPTH • MINIMUM 2,000 PSI INSTALLATION PRESSURE • MINIMUM 1/4" FOUNDATION LIFT DURING INSTALLATION 8• INDICATES LOCATION OF 2%" 0 PIN PILE W/ FSI FS238B FOUNDATION BRACKET PER DETAILS ON S4.2 ((6) TOTAL) PIN PILE INSTALLATION NOTES: • MAX LOAD TO ANCHOR = 3,489 LBS • 2.375"0 PIPE PILE W/ 0.154" THICK WALL • MINIMUM 10'-0" INSTALLATION DEPTH • DRIVE UNTIL LESS THAN 1" MOVEMENT IS OBSERVED IN A 1 MIN TIME SPAN WITH A 110LB (OR 140LB) PNEUMATIC HAMMER 9• PIER SPACING SHALL BE AS INDICATED ON PLAN UNO 10. CONTRACTOR TO NOTIFY ENGINEER OF RECORD IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATION BRACKETS 11. ®INDICATES LOCATION OF SAFEBASEMENT FLOOR STABILIZER W/ LIGHTFOOT STABILIZER BASE ((11) TOTAL) MAX LOAD TO STABILIZER = 3,072 LBS 12. REPLACE "IN —KIND" ALL (E) WOOD MEMBERS (JOISTS, PURLINS, SUBPURLINS, SHEATHING, STUDS, WALL PLATES) WHICH SHOW SIGNS OF DRY ROT OR STRUCTURAL DAMAGE 13. CONTRACTOR SHALL NOT REMOVE ANY (E) POSTS OR PRE —CAST FOOTINGS SUPPORTING THE (E) FLOOR FRAMING 14. FILL ALL VISIBLE CRACKS IN THE FOUNDATION WALL WITH HYDRAULIC CEMENT OR EPDXY 15. ALL CONSTRUCTION MATERIALS IN THESE DOCUMENTS ARE (N) LINO 16. [:] INDICATES APPROXIMATE LOCATION OF NCFI GEOTECHNICAL TERRATHANE 24-010 POLYURETHANE FOAM OR EQUIVALENT PER CONTRACTOR AS REQ'D. REF DETAIL 2/S4.4 I N LO ^I 00 I B C 1p� 10" 16'-0" 8'-5" 16'-5" 24'-0" 2'-0" I(4) EQ SPACES 2'-0" r VnlnrP. in /nA /nI (E) FOUNDATION/(N) PIER/(N) FLOOR STABILIZER LAYOUT PLi4wpo SCALE: '/8"=1'-0" CITY OF DEVELOPMI PI AN sfa 5FA Design Group, LLr PortlandR ORoI' Livermore,' CAI Seattle, WA p��5R3�fi61�8311 www.sfatlg.com 0 z_ z z_ O_ rr Lu 0 z N Lu co Q CU � z U) Lu N o Q NO U) o o Lu w rr Lu z z_ (E) FDN/(N) PIER/ (N) FLR STABILIZER LAYOUT PLAN [REVISIONS 1 PROJECT NO: MFR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 SHEET NO: S2.1 1 S4.1 OPP q/HOLES/ � '/8"0 HOLE TYP ---, Q � 6 LINE OF SYMMETRY 4 � g" 0 HOLE 21f 5 BEYOND ' 4 1 S4.1 SB-LD BRACKET - TOP flo 7/8"0 HOLE TYP �-/R/PIPE/HOLES 4 EA SIDE OF R 3/16 1-2 \-4" 0x0.39"x0'-9" PIPE EA SIDE OF R 1 /S4.1 LINE OF SYMMETRY ■ 1/16,10 I�I■■I�d • 8" NOTES: r- REF 1 /S4.1 FOR MATERIALS LIST SB-LD BRACKET - FRONT BEYOND 4 SCALE: 1 1/2"=1'-0" SAFEBASE-SD FOUNDATION BRACKET MATERIALS LIST ITEM # PART DESCRIPTION DIMENSIONS GRADE 1 MAIN R V3/4x5x0'-93/4" A36 2 SEAT R El/4x10x0'-10" A36 3 BACK R R1/4x7x0'-10" A36 4 TOP R R3/4x3l/2xO'-81/2" A36 5 STRAP BENT E%x3x2'-O" A36 6 MAIN TUBE* HSS 31/2"OX0.188X0'-9" A500 7 ALL THREADED RODS (2x) 3/4"ox1'-0" A193 8 THREADED HEX NUTS (4x) - A194 9 PUSH PIER SHAFT* PIPE 2.875"OX0.188x4'-O" A500 10 PUSH PIER EXTERNAL SLEEVE** PIPE 3.50"Ox0.220x3'-O" A500 11 FRICTION REDUCER** PIPE 3"00.1880'-1" A53 * DIMENSIONS GIVEN AS OUTER DIAMETER x WALL THICKNESS x LENGTH ** ITEMS NOT SHOWN FOR CLARITY 1 S4.1 1' mi.] NOTES: REF 1 /S4.1 FOR MATERIALS LIST SB-LD BRACKET - SIDE I N SCALE: 1 1/2"=1 '-O" EXPIRES: 04/04/24 SCALE: 1 1/2"=1 '-O" 1 S4.1 o ' _ LINE OF 7 SYMMETRY 8 %g O HOLE YP NOTES: REF 1 /S4.1 FOR MATERIALS LIST SB-LD BRACKET - BACKRECEI 0 SCALE: 1 1/2"� v oroM i DEVELOPMENT SER DEPARTMENT sfa 5FA Design Group, LLr ,.Z. ORcI'Livermore,'CA Seattle, WAI p:(503)91.8311 www.sfadg.com 0 z z z 0- rr 0 z N cl) co C7 W co Q 3: CU � z (D U) Z w N Q O N U) co 0 W w Q W z_ BRACKET DETAILS REVISIONS PROJECT NO: MFR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 SHEET NO: S4.1 F. AL 2 54.2 1/ 4 �-/HOLES/PIER/ROD's 1/ 4 OF hL CAP R NOT SHOWN FOR CLARITY FS238B BRACKET - TOP SCALE: 11/2"=1 ' -O" 1 S4.2 �-/HOLES/PIER/ROD's N ' .� (n � f) 5 I *1 6" \\ III 1 Ln AL I 6 S4.2 FS238B BRACKET - RIGHT SCALE: 11/2"=1 ' -O" N 'N 1>_2„ 4 �-/HOLES 7" /PIER/ROD's I 6 S4.2 FS238B BRACKET - LEFT SCALE: 11/2"=1 ' -O" 1 CONFINING RING WELDED TO ONE SIDE 1 S4.2 X-11 _ CAP R3/4x33/4xO'-53/4" SECTION A -A fA Ai O O N C N O II II O p p T-/HOLES -1- �-/PIER/SYM 4 AL I 6 S4.2 FS238B BRACKET - FRONT SCALE: 1 1/2"=1 ' -O" M M N O O U j C-:)j Y4� EXPIRES: 04/04/24 1,V4>, �-/HOLE/PIER/SYM ' I 6 S4.2 FS238B BRACKET - BACK SCALE: 1 1/2"=1'-O" 4 S4.2 _ C � /4 2 S4.2 /_HOLE PIER/SYM 1 sfa 5FA Design Group, LLr PortlandR ORoI' Livermore, CA l Seattle, WA p��5R3�fi61�8311 www.sfatlg.com z_ z z_ rr w 0 z N O7 W cl) Q U �� zcli w N Z 0 N U) 00o W w rr rr LU z z BRACKET DETAILS [REVISIONS 1 PROJECT NO: MFR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 FS238B BRACKET - BOT EI SHEET NO: 1 (� 026 S4.2 SCALE: 11/2"51 ' OP EDM DS DEVELOPMENT SER DEPARTMENT (E) WALL SHEATHING (E) EXTERIOR SURFACES (SAWCUT AS a REQ'D) ((E) EXTERIOR ° GRADE AS OCCURS) m ;III —III —III a .. ° a ;IIIIIIIIIIIIII, 0 DIRECT INJECTION POLYURETHANE PER PLAN (E) WALL FRAMING (E) FLOOR SHEATHING (E) FLOOR FRAMING (PARALLEL AS OCCURS) (E) CONC STEMWALL (E) INTERIOR GRADE (E) CONC FOOTING (CHIP FLUSH W/ STEMWALL AS REQ'D) -FOUNDATION BRACKET PER PLAN SAFEBASE PUSH PIER & EXTERNAL SLEEVE PER PLAN POL NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S (N) PUSH PIER TO (E) FOUNDATION DETAIL SCALE: 1 "=1'-O" PIER &­ EXTERNAL NOTE: SLEEVE PER PLAN REF PLAN FOR LAYOUT & INSTALLATION REQ'S RECE (N) PUSH PIER TO (E) FOUNDATION DETAIL n V SCALE: 1 "_ rITY OF EDM I DEVELOPMENT SER DEPARTMENT sfa 5FA Design Group, LLr lrIllrl rool P'im"d RORcI'Livermore,fCA (Seattle, WA p: (503) 91.8311 .—fadg.o.m 0 z_ z z_ O_ rr W 0 z N W co Q CU � z U) w N Z Q NO U) co o W w Lu z_ DETAILS [REVISIONS 1 PROJECT NO: MFR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 SHEET NO: S4.3 (E) WALL SHEATHING (E) EXTERIOR SURFACES (SAWCUT AS REQ'D) ((E) EXTERIOR GRADE AS OCCURS) DIRECT INJECTION POLYURETHANE PER PLAN (E) WALL FRAMING (E) FLOOR SHEATHING L (E) FLOOR FRAMING (PARALLEL AS OCCURS) (E) CONC STEMWALL (E) INTERIOR GRADE III—III— I'' e =1 11= I PIN PILE PER PLAN NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S (N) PIN PILE TO (E) FOUNDATION DETAIL SCALE: 1 "=1'-0" (E) WALL FRAMING (E) WALL SHEATHING (E) CONC STEMWALL i DIRECT INJECTION POLYURETHANE PER PLAN NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S DIRECT INJECTION VOID FILL DETAIL EXPIRES: 04/04/24 11,,-5/8"0 HOLE DRILLED FOR PRIMARY INJECTION POINT a SPHERE OF INFLUENCE TYP RECEI 0 SCALE: 1 "=1I9F EDM I TY DEVELOPMENT SER DEPARTMENT sfa 5FA Design Group, LLr lrIllrl rool P'im"d RORcI'Livermore,fCA (Seattle, WA p: (503) 91.8311 .—.efadg.o.m 0 z_ z z_ rr W 0 z N W co Q CU � 3: z U) w N Z Q NO U) 00 0 W w Q W z DETAILS REVISIONS PROJECT NO: MFR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 SHEET NO: S4.4 I ' N (E) INTERIOR GRADE NOTES: 1. REF PLAN FOR LAYOUT & INSTALLATION REQ'S 2. INSTALL PER MFR RECOMMENDATIONS LF STABILIZER IN CRAWLSPACE (E) FLOOR SHEATHING R FRAMING <31/2x% -NTAL BEAM \DLE OR BEAM -R GENERAL NOTES ROD PER NOTES CAP PER NOTES E PER NOTES F FOOTING PER NOTES SCALE: 1 "=1'-0" (E) FLOOR SHEATHING �-/MECHANICAL TUBING (E) FLOOR F---=-----_� JOIST TYP HSS BEAM PEF STEEL BEAM END CONDITION EXPIRES: 04/04/24 NOTE: REF 1/S4.5 FOR CALLOUTS IN COMMON (N) FLR STABILIZER W/ SUPPLEMENTAL BERWE vi SCALE: 1"O TYl-jiF EDM I DEVELOPMENT SER DEPARTMENT SFA Design Group, LLL P_1"d ROR`I'Livermore,fCA (Seattle, WA p: (50)91.8311 .—fadg-m 0 z_ z z 0- rr w Q � z co co L u cn Q z CO cn w N Z Q co O _ N 00 0 w LU rr Q W z z_ DETAILS (REVISIONS 1 PROJECT NO: M FR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 SHEET NO: S4.5 (E) FLOOR SHEATHING (E) FLOOR FRAMING TYP �(Ei FLOOR BEAM (4 /2"W MIN) (E) INTERIOR GRADE NOTES: 1. REF PLAN FOR LAYOUT & INSTALLATION REQ'S 2. INSTALL PER MFR RECOMMENDATIONS LF STABILIZER IN CRAWLSPACE TOP PLATE PER GENERAL NOTES W/ (4) #9X3" WOOD SCREWS THREADED ROD PER GENERAL NOTES THREADED CAP PER GENERAL NOTES MAIN TUBE PER GENERAL NOTES LIGHTFOOT FOOTING PER GENERAL NOTES SCALE: 1 "=1'-0" EXPIRES: 04/04/24 RECEIVED Sep 06 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SFA Design Group, LLL P_1"d ROR`I'Livermore,fCA (Seattle, WA p: (50)91.8311 .—fadg-m 0 z_ z z 0- rr LJJ CI � z Q co rn Lu U) Q U T� z CO cn w N Z Q co O _ N co 0 Lu w Q Lu z z_ DETAIL (REVISIONS 1 PROJECT NO: M FR22-157 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: JLD DATE: 08.30.2022 SHEET NO: S4.6