FIR2022-0064+Fire_Alarm_Equipment_Specification_Sheets+6.29.2022_10.13.44_AM+2960927Johnson 0)114 Controls REVIEWED BY CITY OF EDMONDS Johnson Controls Fire Protection 952010th Avenue South, Suite 100 Seattle, WA 98108 Phone: 206-291-1400 Fax: 206-291-1500 www.JohnsonControls.com RECEIVED Jun 30 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Building Systems Submittal Package Swedish Medical Center 21601 76th Ave West Edmonds, WA 98026 Edmonds Campus Basment Flow Switch Fire Alarm System TI June 22nd, 2022 FIR2022-0064 Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls This Page Left Blank Intentionally Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls Table of Contents Section I: Scheduling/installation Checklist Section II: Hardware Warranty Section III: Manufacturer's Recommendation Section IV: Testing Procedure for Devices Section V: Equipment List & Equipment Datasheets Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson ))) Controls Scheduling Thank you for working with Johnson Controls on this project. We would like to take this opportunity to introduce you to the project team. REILLY NELSON is the Johnson Controls Project Manager assigned to this project to help with generic project information. ERIC BECK is the project system specialist to assist with drawings/design questions. YVONNE THOMPSON is available for scheduling technicians. Office: (206) 291-1400 Fax: (206) 291-1500 In an effort to assist you in your installation we require you to arrange a Pre -Construction meeting with one of our Technicians. This meeting will allow your Feld foreman to ask any questions they may have in regard to the installation of your system. Based on the equipment quantities and current scope of work our Technician will need no less than 30 business days to complete all necessary programming and commissioning from the time the below checklist is complete prior to any AHJ testing. Please make sure this time is allowed for in the General Construction CPM schedule as it cannot be compressed. Change orders, change of scope, etc. may require additional time allotment to field personnel. Installation Checklist Johnson Controls is committed to providing the highest quality service available. As part of this service we want to ensure that the installation results in a trouble -free system. Please review the Checklist below and ensure each item is complete prior to our site visit. A Technician will be dispatched only after the below checklist items have been completed. If these items are not completed prior to the visit by our technician, you may incur additional charges not covered by our quotation. Please feel free to contact our office if you have any questions. o Fire Alarm Panel(s) have been mounted and all wiring (power, IDNET, signal, door -holders, etc.) pulled into panel(s). o All wiring pulled into panel(s) or junction boxes have been permanently marked with wire markers and can easily be identified by a Johnson Controls o System Power is supplied and on a dedicated circuit (Do Not Energize prior to Technician visit). o All peripheral devices have been mounted (Smoke Detectors still covered). o All end -of -line resistors have been installed. o All alarm initiating circuits (smoke detectors, pull stations, etc.) have been checked for shorts, opens and grounds. o All alarm notification circuits (speakers, horns, strobes, etc.) have been checked for shorts, opens and grounds. o All remaining wiring (door -holders, FACP 24VDC, etc.) has been checked. o Flows, Tampers, and Pressure Switches installed, properly wired and adjusted. o All devices are properly protected against construction dust and contamination. o Contact us immediately if there is no digital dialer or system monitoring provisions already in place. The dialer, phone lines and service will be required for system testing. o There are no missing parts or equipment. Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls Hardware Warranty 1) JOHNSON CONTROLS WARRANTY STATEMENT: a) JOHNSON CONTROLS WARRANTS TO THE PURCHASER OF NEW JOHNSON CONTROLS PRODUCT(S) THAT THE PRODUCTS SHALL BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAL. 2) WARRANTY PERIOD: a) THE WARRANTY PERIOD WILL TERMINATE IMMEDIATELY FOLLOWING THE EARLIEST OCCURRENCE OF EITHER OF THE FOLLOWING: i) 18 MONTHS HAVE ELAPSED FOLLOWING SHIPMENT OF ANY SYSTEM OR SUB -SYSTEM FROM JOHNSON CONTROLS TO THE CUSTOMER, OR ii) 12 MONTHS HAVE ELAPSED FOLLOWING THE FINAL CONNECTION OPERATION AND BENEFICIAL USE OF ALL OR ANY PART OF THE SYSTEM. iii) AS STATED IN THE SPECIFICATIONS AND/OR CONTRACT DRAWINGS 3) JOHNSON CONTROLS OBLIGATION UNDER THE TERMS OF THE WARRANTY: a) JOHNSON CONTROLS's SOLE RESPONSIBILITY SHALL BE TO REPAIR, ADJUST OR REPLACE, AT ITS OPTION, ANY JOHNSON CONTROLS PRODUCT WHICH FAILS DURING THIS PERIOD PROVIDING PURCHASER HAS PROMPTLY REPORTED SUCH FAILURE TO JOHNSON CONTROLS IN WRITING. REPLACEMENT PARTS WILL BE WARRANTED ONLY FOR THE BALANCE OF THE EQUIPMENT WARRANTY. JOHNSON CONTROLS AGREES TO CONTINUE TO HONOR ALL OF THE UNEXPIRED EXPRESSED WARRANTIES SPECIFIED ABOVE ON DEFECTIVE EQUIPMENT AFTER TRANSFER OF THE EQUIPMENT TO PURCHASER'S CUSTOMER, PROVIDED PURCHASER'S CUSTOMER ASSUMES THE PURCHASER'S OBLIGATIONS SPECIFIED BELOW. b) EXCEPT FOR THE EXPRESSED WARRANTIES STATED HEREIN, JOHNSON CONTROLS DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HEREUNDER, INCLUDING WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE STATED WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR LIABILITIES ON THE PART OF THE JOHNSON CONTROLS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE PRODUCTS. THE SELLER SHALL NOT BE LIABLE FOR ANY DIRECT, INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGE TO THE PRUCHASER OR USER OF THIS EQUIPMENT ARISING OUT OF THE FAILURE OF THE EQUIPMENT TO OPERATE IN EXCESS OF THE PURCHASE PRICE OF SAID EQUIPMENT. c) JOHNSON CONTROLS MAKES NO WARRANTY AND NO WARRANTY SHALL BE DEEMED TO EXIST, THAT PURCHASER HOLDS THE GOODS FREE OF THE CLAIM OF ANY THIRD PERSON BYWAY OF PATENT INFRINGEMENT OR THE LIKE. 4) PURCHASER'S OBLIGATIONS UNDER THE TERMS OF THE WARRANTY. a) THIS WARRANTY IS CONTINGENT UPON THE PROPER INSTALLATION AND USE OF THE PRODUCT(S). SUCH WARRANTY SHALL NOT APPLY IF THE PRODUCT FAILURE IS THE RESULT OF ACCIDENT, UNUSUAL PHYSICAL, ELECTRICAL OR ELECTROMECHANICAL STRESS, NEGLECT, MISUSE, USER PROGRAMMING ERRORS, FAILURE OF ELECTRICAL POWER, AIR CONDITIONING OR HUMIDITY CONTROL, CONSTRUCTION DUST, DAMAGING FOREIGN SUBSTANCES, TRANSPORTATION OR CAUSES OTHER THAN MANUFACTURING DEFECT. PURCHASER AGREES TO PROVIDE FULL AND FREE ACCESS TO AUTHORIZED JOHNSON CONTROLS EMPLOYEES. b) WARRANTY SERVICE HOURS SERVICES PROVIDED UNDER THIS WARRANTY WILL BE PERFORMED DURING THE HOURS OF 8:OOA.M. TO 5:OOP.M., MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED JOHNSON CONTROLS HOLIDAYS. OFF HOURS RESPONSE IS AVAILABLE AS AN EXTRA COST SERVICE OPTION. 5) WARRANTY EXCLUSIONS: a) LABOR, TRAVEL, AND MILEAGE FOR: i) SERVICE OUTSIDE OF JOHNSON CONTROLS NORMAL BUSINESS HOURS. ii) PROGRAMMING AND/OR LABEL CHANGES. iii) FAILURE DUE TO EXTERNAL CAUSES (LIGHTNING SURGES, CONSTRUCTION DUST, ETC.) OTHER THAN MANUFACTURING DEFECT. b) ELECTRICAL WORK EXTERNAL TO THE EQUIPMENT SUPPLIED BY JOHNSON CONTROLS OR MAINTENANCE OF ACCESSORIES, ALTERATIONS. ATTACHMENTS OR OTHER DEVICES NOT FURNISHED BY JOHNSON CONTROLS. c) BATTERIES. d) COVERAGE OF EQUIPMENT CLASSED AS A WATER FLOW MONITORING/CONTROL DEVICES INSTALLED IN OR ON WATER PIPING. Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson # Controls Manufacturer's Recommendation 1) CONTRACTOR IS EXPECTED TO PULL AND TERMINATE ALL CONDUCTORS AND INSTALL ALL DEVICES FOR A COMPLETE AND OPERATING SYSTEM. 2) WHERE FAN SHUTDOWN, ELEVATOR RECALL OR SPECIAL AUXILIARY FUNCTIONS ARE REQUIRED, CONTRACTOR IS TO VERIFY WIRING REQUIREMENTS WITH THE JOHNSON CONTROLS FACTORY TECHNICIAN ASSIGNED TO THE PROJECT (IN MANY CASES, SPECIAL WIRING WILL NOT BE SHOWN ON THE DRAWINGS). 3) WHERE POSSIBLE, THE CONTRACTOR IS TO USE COLOR CODE FOR ALL WIRING. 4) SMOKE DETECTORS ARE NOT TO BE MOUNTED WITHIN 3 FEET OF AIR OUTLETS. 5) CONTRACTOR MUST NOT INSTALL SMOKE DETECTOR HEADS IN BASES OR DUCT HOUSING UNTIL FINAL CHECKOUT TIME TO ENSURE THAT DIRT OR DUST DOES NOT CONTAMINATE THE UNITS. DIRTY DETECTORS ARE NOT COVERED BY WARRANTY. 6) DO NOT POWER -UP SYSTEM UNTIL JOHNSON CONTROLS FACTORY TECHNICIAN IS PRESENT. 7) A SEPARATE GROUND (ISOLATION FROM CONDUIT GROUND) MUST BE PULLED TO ALL CABINETS. 8) LOADS GREATER THAN 10 AMPS (FOR AUXILIARY FUNCTIONS) ARE NOT ALLOWED IN THE SAME CONDUIT AS FIRE ALARM. 9) CONTRACTOR IS TO ENSURE THAT ALL WIRING AND SHIELDS ARE FREE OF SHORTS, GROUNDS AND OPENS. 10) UNDERGROUND WIRING MUST MAINTAIN ONE MEGAOHM, 20F RESISTANCE TO GROUND. 11) ANY MANUFACTURER'S RECOMMENDATION IN CONFLICT WITH ENGINEERING DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION. CONTRACTOR SHALL ADVISE JOHNSON CONTROLS OF ANY CHANGES. 12) PROTECTIVE COVERS ON SMOKE DETECTORS ARE NOT TO BE REMOVED UNTIL OWNERS ACCEPTANCE OF THE SYSTEM. (PREVENTS CONTAMINATION OF SMOKE CHAMBER). 13) IT IS THE CONTRACTOR'S RESPONSIBILITY TO REQUEST THE STATE OR LOCAL FIRE MARSHAL TO BE ON SITE FOR FINAL ACCEPTANCE AND CHECK OUT IF REQUIRED. 14) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INVENTORY ALL EQUIPMENT RECEIVED FROM JOHNSON CONTROLS AGAINST THE CONTRACT DOCUMENTS AND REPORT ANY DISCREPANCIES WITHIN THIRTY (30) DAYS OR JOHNSON CONTROLS WILL ASSUME THE ORDER TO BE ACCURATE AND COMPLETE. a) `NOTE: IN THE EVENT OF DISCREPANCIES IN THE NUMBER OF DEVICES SUPPLIED, THE FOLLOWING JOHNSON CONTROLS POLICY WILL APPLY: TOO FEW DEVICES: IF THE DEVICE IS SHOWN ON THE CONTRACT DOCUMENTS AND HAS NOT BEEN ADDED AS A RESULT OF A POST BID ADDITION OR CHANGE ORDER, JOHNSON CONTROLS WILL SUPPLY THE DEVICE AT NO CHARGE TO THE CONTRACTOR OR END USER PER JOHNSON CONTROLS'S CONTRACT OBLIGATIONS. ii) TOO MANY DEVICES: IF THE DEVICE SHOWN IS EXTRA, DUE TO A POST BID ADDITION OR CHANGE ORDER; IT REMAINS THE PROPERTY OF THE CONTRACTOR OR END USER. IF THE DEVICE IS EXTRA DUE TO AN ERROR IN QUANTITIES SUPPLIED, THE DEVICE MUST BE RETURNED TO JOHNSON CONTROLS. NO CREDIT WILL BE ISSUED FOR THE RETURN OF EXTRA EQUIPMENT ABOVE THE QUANTITIES GIVEN IN THE CONTRACT DOCUMENTS. 15) OWNERS PRESENCE FOR FINAL DEMONSTRATION AND ACCEPTANCE. Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson 0 Controls Special Instructions - Johnson Controls 1) JOHNSON CONTROLS WILL PROVIDE WIRING INSTRUCTIONS FOR INSTALLATION OF JOHNSON CONTROLS EQUIPMENT. 2) JOHNSON CONTROLS WILL PROVIDE A FACTORY TRAINED TECHNICIAN TO ASSIST IN TRAINING: a) OPERATION OF THE CONTROL PANEL AND FUNCTIONS b) ALARM TEST OF ALL JOHNSON CONTROLS PERIPHERAL DEVICES (SMOKE DETECTOR, MANUAL PULL STATION, ETC.) c) SUPERVISE TEST OF ALL INITIATING, SIGNALING, AND CONTROL CIRCUITS. 3) JOHNSON CONTROLS WILL PROVIDE (1) INSTRUCTION AT FINAL TEST OF THE SYSTEM TO: a) OWNER REPRESENTATIVE b) FIRE INSPECTOR AND ELECTRICAL INSPECTOR c) ARCHITECT AND ENGINEER 4) UPON COMPLETION OF FINAL TEST, JOHNSON CONTROLS WILL PROVIDE: a) TEST REPORT b) CERTIFICATION (IF REQUIRED) c) ONE YEAR WARRANTY Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls Testing Procedure for Devices GENERAL: FOR ALL DEVICES (SUPPLIED BY JOHNSON CONTROLS) VISUALLY VERIFY PROPER LOCATION AND INSTALLATION. SMOKE DETECTOR: ACTIVATE THE DEVICE USING A SMOKE GENERATOR AND VERIFY ALARM CONDITION ON PANEL. RESET PANEL AND VERIFY RESET OF SMOKE DETECTOR AND PANEL. TEST FOR ALARM VERIFICATION IF APPROPRIATE. HEAT DETECTOR: FIXED TEMPERATURE REPLACEMENT ELEMENT - REMOVE ELEMENT ON HEAT DETECTOR TO INITIATE ALARM AND VERIFY ALARM CONDITION AT PANEL. REINSTALL ELEMENT, RESET SYSTEM, AND VERIFY. NON -REPLACEABLE ELEMENT - NON -REPLACEABLE ELEMENT HEAT DETECTORS CAN ONLY BE TESTED FOR CONTINUITY. RATE -OF -RISE DETECTORS - RATE OF RISE DETECTORS ARE TESTED WITH A HEATER OR BLOW DRYER UNTIL THEY INITIATE ALARM, THEN ALLOWED TO COOL. RESET PANEL AND VERIFY. PULL STATIONS: ACTIVATE STATION WITH THE T-HANDLE, VERIFY ALARM AND LABEL FOR LOCATION, RESET STATION, RESET PANEL. DUCT DETECTOR: (IF PROVIDED BY JOHNSON CONTROLS) WITH AIR HANDLING UNIT TURNED ON, OPEN ONE OF THE TEST PORT HOLES BY REMOVING THE RED COVER ON THE DUCT DETECTOR/SENSOR HOUSING. USING AN EXTENDED NOZZLE ON THE SMOKE DETECTOR AEROSOL TESTER SPRAY A FOUR TO EIGHT SECOND BURST OF AEROSOL THROUGH THE TEST PORT BUT NOT DIRECTLY AT THE DETECTOR/SENSOR HEAD. THE NOZZLE OF THE SMOKE DETECTOR AREOSOL TESTER SHOULD NOT EXTEND BEYOND THE INLET TUBE. AEROSOL IS SPRAYED INTO THE STREAM OF INCOMING AIR AND NOT DIRECTLY INTO DETECTOR/SENSOR. VERIFY ALARM, TEST ALL INDICATORS OR MANUAL TEST SWITCHES, RESET DETECTOR, RESET PANEL, TEST SAMPLE AND REFERENCE TUBE FOR POSITIVE AIR FLOW. (IF NOT PROVIDED BY JOHNSON CONTROLS) VERIFY THAT ZONE CIRCUIT IS PRESENT AT THE DEVICE. AUDIBLES AND VISIBLES: ACTIVATE ALARM AND CONFIRM THAT ALL INDICATING APPLIANCES, AUDIBLES AND VISIBLES, ARE OPERATING. DOOR HOLDERS: VERIFY THAT DOORS CLOSE ON ALARM. VALVE SUPERVISORY SWITCHES (TAMPER): (IF PROVIDED BY JOHNSON CONTROLS) ACTIVATE SWITCH BY MOVING VALVE OFF NORMAL, VERIFY STATUS CHANGE, RESET SWITCH, RESET PANEL. (IF NOT PROVIDED BY JOHNSON CONTROLS) VERIFY THAT ZONE CIRCUIT IS PRESENT AT THE SWITCH. FLOW SWITCHES AND PRESSURE SWITCHES: (IF PROVIDED BY JOHNSON CONTROLS) ACTIVATE SWITCH (WITH SPRINKLER CONTRACTOR PRESENT) BY A FLOW OF WATER, VERIFY STATUS CHANGE, RESET SWITCHES, RESET PANEL. (IF NOT PROVIDED BY JOHNSON CONTROLS) VERIFY THAT ZONE CIRCUIT IS PRESENT AND SUPERVISED AT THE SWITCH. FAN/DAMPER CONTROL CIRCUITS: VERIFY (WITH HVAC CONTRACTOR PRESENT) THAT THE CONTROL CIRCUIT IS OPERATING, AND THE DEVICES IS BEING CONTROLLED IN ACCORDANCE WITH THE SPECIFIED SEQUENCE OF OPERATION. ELEVATOR CONTROL CIRCUITS: VERIFY (WITH ELEVATOR CONTRACTOR PRESENT) THAT THE ELEVATOR IS BEING CONTROLLED IN ACCORDANCE WITH THE SPECIFIED SEQUENCE OF OPERATION. TRAINING: JOHNSON CONTROLS SHALL PROVIDE A ONE TRAINING SESSION TO THE CUSTOMER. WARRANTY: THE SYSTEM SHALL BE PROVIDED WITH A ONE YEAR HARDWARE WARRANTY. Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls Equipment List & Data Sheets Fire Alarm System Quantity Product ID Product Description 4090-9001 Supervised IAM Module (Addressable) Equipment List Subject to Change. Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World 13®SimplEx UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: • Supervised Class B monitoring of normally open, dry contacts • Total wiring distance from IAM to supervision resistor(s) of up to 500 ft (152 m) • Monitored connection is compatible with Simplex 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications • For use in indoor locations up to 158' F (70' C) such as attic spaces or similar applications For use with following Simplex control panels: • Model Series 4007ES, 4008, 4010, 4010ES, and 4100ES fire alarm control panels for IDNet communications • Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: • Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: • Encapsulated design for extended exposure to high humidity (LED is not present on this model) • Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: • Provides monitoring of tamper switch (supervisory) and waterflow switch (alarm) on same circuit using one point • Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: • Contact closure status can be tracked • Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use — City of New York Department of Buildings — MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products . Multi -Application Peripherals IDNet and MAPNET II Communicating Devices, Individual Addressable Modules (IAMs) slNriElmp 4090 90010 SUPENVISED IAN W. licit. 511-33, DATE CODE: M roNe 2 ,�"� �" 4 N. 9 gg:o 00 4090-9001 Supervised IAM (shown approximately 3/4 size) 4090-9051 Supervised IAM (shown approximately 3/4 size) ]esrrintir Individual addressable modules (IAMs) receive both power and communications from a two -wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end -of -line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. M [II!I131lolol i BE i ME FW171 C I DnPrafir Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate -of -rise heat detector, or to track the device contact status (not available with the 2120 CDT). IAM Product Selection For use with IDNet communications only, these IAMB can provide quad -state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end -of -line and current limiting resistors, dual functions such as tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable point. Model Description 4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 I Supervised IAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi -flush mounted box 4090-9807 I For surface mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End -of -Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kQ, 1/2 W; Standard end -of -line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 kQ, 1 /2 W Use for current limited monitoring applications 4081-9005 733-984 1.8 kQ, 1 /2 W Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per IAM Input Requirements Normally open, dry contacts Wire Connections 4090-9001 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 MM2 to 2.08 mm ) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from IAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 4090-9051 1-9/16" W x 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) 1-9/16" W x 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 158° F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-11 11/2014 Mounting Information 4-1/4" (108 mm) 4090-9001 I D Net supervised IAM si�EE ri,E A EOAOER 4090-9001�` suPEAuisEo uu DATE CODE CODESId-);I M ID" Field wiring shown for reference 10) LED viewing port Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate � III I Light pipe for � a.0(� DISCONNECT POWER BEFORE SERVICING LE LED viewing 2-1/2" No (64 mm) 4090-9806, Trim plate for semi -flush mounted box DISCONNECT POWER BEFORE SERVICING 2-13/16" (72 mm)0. 4090-9807, Trim plate for surface mounted box 0 0 4-1/2" (114 mm) 0 0 NOTE: These mounting plates require mounting bracket 4090-9810. 4090-9810 Mounting bracket, ordered separately Optional Trim Plates and Mounting Bracket for Visible LED S4090-0001-11 11/2014 4090-9051 Mounting Information Address setting is \ at rear of housing 4090-9051 Encapsulated Supervised IAM Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) 13®Sim plEX Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4090-0001-11 11/2014 www.simplex-fire.com C 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other infoumation shown were current as of document revision date and are subject to change without notice.