Loading...
Water Availability Letter - 730 Cary RdOf 1; rs�y WATER AVAILABILITY CERTIFICATE �n ' i;,,,, PERMITTING & DEVELOPMENT ENGINEERING DIVISION 121 5th Avenue N P: 425.771.0220 www.edmondswa.gov ITEMS IN THIS BOX TO BE FILLED IN BY APPLICANT I/Building Permit ❑ Preliminary Plat or PUD ❑ Subdivision ❑ Rezone or Other Applicant's name: Paul Stromme Proposed Use: SFR with sprinkling Location (attach map and legal description if necessary): 730 Cary Road Updated on 8/14/2018 Pam I of 2 ITEMS IN THIS BOX TO BE FILLED IN BY EDMONDS DEVELOPMENT SERVI EC S DEPARTMENT Permit Number BLD20190155 Project Name NEW SFR M a. Water will be provided by service connection only to an existing 8 inch (size) water main that is adjacent from the site. OR ❑ b. Water service will require an improvement to the water system of: ❑ (1). feet of water main to reach the site; and/or ❑ (2). The construction of a distribution system on the site; and/or ❑ (3). Other (describe): 2. ® a. The water system is in conformance with a City approved water comprehensive plan. OR ❑ b. The water system improvement will require a water comprehensive plan amendment. (This will cause a delay in permit issuance and approval.) 3. ® a. The proposed project is within the corporate limits of the City, or has been granted Boundary Review board approval for extension of service outside the City, or is within the City approved service area of a private water purveyor. OR ❑ b. Annexation or Boundary Review Board approval will be necessary to provide service. 4. ® a. Water is/or will be available at the rate of flow and duration indicated below at no less than 20 psi Measured at the nearest fire hydrant 61 feet from the building/property (or as marked on attached Rate of Flow Duration ❑ Less than 500 gpm. (approximately gpm) ❑ Less than one (1) hour ❑ 500 to 999 gpm ❑ One (1) to two (2) hours ❑ 1500 gpm or more ® Two (2) hours or more ❑ Flow test of gpm ❑ Other ® Calculation of 2908.49 gpm (Commercial building permits require flow test or map) OR ❑ b. Water will system is not capable of providing fire flow. WATER AGENCY CERTIFICATION COMMENTS/CONDITIONS: Per model. Static Pressure is 115.Q2_psi at 1000 cipm, residual pressure is 108.48 psi at max flow of 2908.49 gpm, residual gressure is 67.13 psi I hereby certify that the above water purveyor information is true. This certification shall be valid for one year from date of signature. City of Edmonds _ _ GregoryMalowicki (Agency Name) Si�latory Printed Nam Associate Engineer r �� (Title) (Signature/Date) Updated on 811412018 Page 2 of2