Loading...
Fire Comments- to be sent at issuanceSOUTH COUNTY FIRE 12425 Meridian Ave S., Everett WA 98208 tel (425) 551-1200 • fax (425) 551-1249 www.southsnofire.org City of Edmonds Department of Fire Prevention Fire Comments: DATE: 4/28/2021 PERMIT #: BLD2021-0427 PERMIT DESCRIPTION: Tenant Improvement and Change of use JOB NAME/ADDRESS: Wonton Noodle but 22921 Highway 99 22931 CONTACTS: FIRE PLAN REVIEW NOTES: The proposed project is approved by Fire, with the following conditions: 1. As stated in the Edmonds Municipal Code 19.25.035, For the purpose of 19.25.035 spaces separated by fire walls, fire barriers, fire partitions and fire resistance rated horizontal assemblies noted in the IBC Chapter 7 shall not be considered separate buildings. 2. As stated in the Edmonds Municipal Code 19.25.035 C. Fire Alarms and Detection Systems. In addition to the requirements of Section 907.2, an approved, monitored automatic fire alarm system shall be installed and maintained throughout all buildings, structures, floors, and suites described in this section. If conflicts exist between the IFC and this section, this section shall prevail. Fire alarm systems shall be installed per NFPA 72 and SCF's fire alarm standard. Partial area fire alarm systems are prohibited except where approved by the fire code official. When required by the International Existing Building Code (IEBC) for existing buildings and structures undergoing additions, alterations, repairs or changes of occupancy. The classification of work level shall be determined by the building and fire code official. 3. This building by the above municipal code could be required to install a fire sprinkler system. In existing buildings that are altered or have a change of use, but do not otherwise require that a fire sprinkler be installed, a fire alarm for the entire building will be required. All class 1 hoods and gas shutoffs will be interconnected with the fire alarm system. Future improvements or occupancy changes could require the space or entire building to be retro fitted with a fire sprinkler system. 4. Occupant load to be determined by building. 5. Addressing 10 - 12 inch numbering on contrasting background. Suite identification 6 inch numbers above door in a contrasting color. 6. 6. Knox box key entry to common areas and access to fire alarm panel AFM Karl Fitterer CFI Assistant Fire Marshal 12425 Meridian Ave. S, Everett WA 98208 0: 425-771-0213 VM: 425-551-1980 KFitterer@southsnofire.org I www.southsnofire.org SERVING SOUTH SNOHOMISH COUNTY • BRIER • EDMONDS • LYNNWOOD • MOUNTLAKE TERRACE Page 1 of 1