APPROVED BLD BLD2021-0430+Plumbing_Plan+3.25.2021_11.39.25_AM+2111508
PROJECT STATISTICS SITE ADDRESS: 22931 HWY 99 EDMONDS, WA 98026 PARCEL NUMBER: 00576700000205 LEGAL DESCRIPTION: SKELTONS LK MC ALEER 5 ACRE TRS BLK 000 D-05 - LOT 2 LY E OF ST RD LESS PTN LY N OF ALN WH BEGINS AAP S02*28 02E 317.34FT FR THE INT OF PRIMARY S/HY NO 1 & E LN SD LOT & EXT S87*56 01W PLW S LN OF SD LOT A DIST OF 157.53FT TO SELY HWYR/W LN AKA LOT 2 OF SP S-39-77 REC AF 7709140278 LESS R/W TO CITY LYNN PER WD REC AF 9712170397 PROPERTY DESCRIPTION: BRENTWOOD PLAZA -COMMERCIAL YEAR BUILT: 1986 ZONING : EDMONDS CITY NEIGHTBORHOOD CODE: 5604000 TOWNSHIP: 27 RANGE: 04 SECTION: 31 QUARTER: NE BUILDING GROSS SQ FT: 13,826 SF. PROJECT AREA: 1,100 SF. PRESENT USE: R - RETAIL GROCERY STORE PROPOSED USE: B - BUSINESS RESTAURANT 35 OCCUPANTS OR LESS CONSTRUCTION TYPE: II -A SPRINKLERS: NO SPRINKLERS PARKING: ADEQUATE CONSTRUCTION COST: $200,000 APPLICABLE CODE • 2018 INTERNATIONAL BUILDING CODE • 2018 INTERNATIONAL EXISTING BUILDING CODE • 2018 UNIFORM PLUMBING CODE SCOPE OF WORK • FURNISH AND INSTALL PLUMBING FIXTURES AND ASSOCIATED COMPONENTS PER PLAN. • FURNISH AND INSTALL NEW DOMESTIC WATER PIPING SYSTEM WITH ALL OTHER ASSOCIATED COMPONENTS PER PLAN. • FURNISH AND INSTALL NEW WASTE, GREASE WASTE, AND VENT SYSTEM WITH ALL OTHER ASSOCIATED COMPONENT PER PLAN. DRAWING INDEX P-1.0 PLUMBING GENERAL INFORMATION P-2.0 POTABLE RISER WATER PLAN P-3.0 WASTE AND VENT RISER PLAN P-4.0 GREASE INTERCEPTOR SPEC SHEET AND DETAILS P-5.0 SPEC SHEET PROJECT TEAM OWNER: IDY CHANG, KAY SAM KO #206-946-5248 UP20027UP@YAHOO.COM.HK DESIGN TEAM: CATCH DESIGN STUDIO 1405 BOYLSTON AVE. SEATTLE, WA 98122 CONTACT: NOS NARIN TEL: 206.322.4323 E-MAIL: NOS@CATCHSTUDIO.COM LEGEND /SYMBOL /ABBREVIATION SYMBOL ABBREV. DESCRIPTION �A POC POINT OF CONNECTION POD POINT OF DISCONNECT C DN PIPE DOWN G- UP PIPE UP FLOW DIRECTION 0I TP TRAP PRIMER W/ WALL ACCESS PANEL -N-N�- BFP BACKFLOW PREVENTER RPBA SOV SHUT-OFF VALVE CKV CHECK VALVE C� BALANCING VALVE GCK GAS COOK FD FD FLOOR DRAIN FFD FFD FLOOR DRAIN W/ FUNNEL O FS FS FLOOR SINK � WCO WCO WALL CLEAN OUT FCO FCO FLOOR CLEAN OUT WATER HAMMER ARRESTOR UNION RELIEF VALVE SYMBOL ABBREV SS SW GW ....... CW HW - HW HWS HWR --------- VTR DESCRIPTION SANITARY SEWER LINE SEWER LINE (NON -GREASE) GREASE WASTE LINE COLD WATER HOT WATER SUPPLY HOT WATER RETURN VENT TO ROOF BURIED PIPE WATER PRESSURE WATER PURVEYOR: SEATTLE PUBLIC UTILITIES AVAILABLE STATIC WATER PRESSURE AT PIPE ENTERING BUILDING IN LEVEL P1 WATER VALVE ROOM = 121 PSI @ XX'. BUILDING IS SEATTLE PUBLIC UTILITIES 326 FT PRESSURE ZONE ALL DOMESTIC WATER FOR BUILDING WILL UTILIZE TWO PRESSURE ZONES WITH A PRESSURE REDUCING STATION TO LIMIT INCOMING PRESSURE. MAX ALLOWABLE PRESSURE TO ANY FIXTURE TO BE 80 PSI PER UPC. CROSS CONTAMINATION CROSS CONTAMINATION CONTROL PROVIDED BY REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY (RPBA) PER THE 2015 UPC SECTION 603 AND CITY OF SEATTLE REQUIREMENTS PIPE MATERIALS - WATER ALL WATER PIPING 2" AND SMALLER TO BE PEX TUBING WITH PEX FITTINGS. NSF RATED ALL WATER PIPING 2-1/2" AND LARGER TO BE STAINLESS STEEL WITH GROOVED STAINLESS STEEL FITTINGS. NSF RATED. THE NUMBER OF FIXTURE UNITS ALLOWABLE ON A 2" PEX PIPE WHEN CALCULATING FOR A 4PS1/100 FT FRICTION IS SIGNIFICANTLY LESS THAN FOR COPPER OR STAINLESS. BEFORE THE PEX IS ALLOWED TO DOWNSIZE TO 1-1/2". WITH THE SMALLER INSIDE DIAMETER OF PEX THE VELOCITIES WILL GREATLY EXCEED WHAT IS OUTLINED AS MAXIMUMS ON THESE DOCUMENTS, AS WELL AS APPENDIX A6.1 IN THE 2015 SPC. PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SIZES CALLED OUT ON PLANS. MAXIMUM WATER VELOCITIES WITHIN PIPING SHALL BE AS FOLLOWS: STAINLESS TUBE AND FITTING SYSTEMS - 10 FT/SEC ON COLD WATER PIPING, 8 FT/SEC ON HOT WATER PIPING, 3 FT/SEC ON HOT WATER RECIRC PIPING PEX TUBE AND FITTING SYSTEMS -10 FT/SEC ON COLD WATER PIPING, 8 FT/SEC ON HOT WATER PIPING, 2 FT/SEC ON HOT WATER RECIRC PIPING MAX ALLOWABLE PRESSURE DROP FROM FRICTION FOR ENTIRE PIPING AND FITTINGS IS 24 PSI PIPE SEGMENTS ON DRAWINGS WITHOUT A SIZE CALLED OUT SHALL BE THE SAME SIZE AS THE PRECEDING UPSTREAM PIPE SEGMENT. PROVIDE DIELECTRIC UNIONS WHERE GALVANICALLY DISSIMILAR METALS JOIN PIPE MATERIALS -SANITARY DRAINAGE CONDENSATE PIPING SHALL BE TYPE 1" COPPER WITH WROT COPPER FITTINGS OR SCH 40 PVC SANITARY DRAINAGE PIPING SHALL BE "NO -HUB" CAST IRON PIPING IN ALL RESIDENTIAL AREAS INCLUDING VERTICAL WASTE STACKS AND ALL DWELLING UNITS WASTE PIPING. PLASTIC PIPING IS TO BE USED IN PARKING GARAGES. PIPING IN RATED PLENUMS TO BE CAST IRON. VENT PIPING SHALL BE CAST IRON WHEN INSTALLED IN RATED PLENUMS IN ALL AREAS OTHER THAN FIRE RATED PLENUMS, VENT PIPING SHALL BE PLASTIC LAVATORY MIXING VALVE PER THE 294 UPC SECTION 421.2 HOW WATER DELIVERED TO PUBLIC -USE LAVATORIES SHALL BE LIMITED TO A MAXIMUM TEMPERATURE OF 120°F BY A DEVICE THAT IS IN ACCORDANCE WITH ASSE 1070 OR CSA B125.3 THE WATER HEATER CONTROL IS NOT CONSIDERED A CONTROL MEETING THIS PROVISION. PUBLIC -USE LAVATORIES SHALL BE DEFINED AS A HAND SINK ADJACENT TO WATER CLOSETS OR URINALS IN NON -LOCKING BATHROOMS INTENDED FOR AN OCCUPANCY OF MORE THAN ONE PERSON AT A TIME. PLUMBING CONTRACTOR TO PROVIDE MIXING VALVES FOR PUBLIC LAVATORIES PER FIXTURE SCHEDULE NATURAL GAS PRESSURE NATURAL GAS PROVIDER: PUGET SOUND ENERGY CONTRACTOR SHALL COORDINATE GAS PRESSURE WITH PUGET SOUND ENERGY TO PROVIDE 2 PSI DELIVERY GAS PRESSURE PROVIDE GAS PRESSURE REGULATOR AS REQUIRED BY EQUIPMENT TO DROP PRESSURE TO REQUIREMENT ON EQUIPMENT. USE OF A GAS PRESSURE REGULATOR THAT REQUIRES VENTING SHALL CONFORM WITH SECTION 410.3 OF THE INTERNATIONAL FUEL GAS CODE. PIPE INSULATION SEC 2015 : SEATTLE ENERGY CODE TABLE C403.2.9 : MINIMUM PIPE INSULATION THICKNESS (INCH) FLUID OPERATING INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE (INCHES) TEMPERATURE RANGE AND USAGE ft) CONDUCTIVITY MEAN RATING <1 1 TO <12 1z TO <4 4 TO <8 >8 BTU . IN./(H.FT2.°F)B TEMPERATURE, °F > 350 0.32 - 0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29 - 0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27 - 0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25 - 0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21 - 0.28 100 1.0 1.0 1.5 1.5 1.5 40-60 0.21 - 0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20 - 0.26 50 0.5 1.0 1.0 1.0 1.5 A. FOR PIPING SMALLER THAN 12 INCHES AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1 INCH SHALL BE PERMITTED (BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE B) BUT NOT TO A THICKNESS LESS THAN 1 INCH. B. FOR INSULATION OUTSIDE THE STATED CONDUCTIVITY RANGE, THE MINIMUM THICKNESS (T) SHALL BE DETERMINED AS FOLLOWS: T = r{ (1 + Vr)Wk -1 } WHERE: T = MINIMUM INSULATION THICKNESS, r = ACTUAL OUTSIDE RADIUS OF PIPE, t = INSULATION THICKNESS LISTED IN THE TABLE FOR APPLICABLE FLUID TEMPERATURE AND PIPE SIZE, K = CONDUCTIVITY OF ALTERNATE MATERIAL AT MEAN RATING TEMPERATURE INDICATED FOR THE APPLICABLE FLUID TEMPERATURE (BTU.IN/H.FT2. °F) AND k = THE UPPER VALUE OF THE CONDUCTIVITY RANGE LISTED IN THE TABLE FOR THE APPLICABLE FLUID TEMPERATURE C. FOR DIRECT -BURIED HEATING AND HOT WATER SYSTEM PIPING, REDUCTION OF THESE THICKNESSES BY 1/2 INCHES (38 MM) SHALL BE PERMITTED BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE B BUT NOT TO THICKNESSES LESS THAN 1 INCH (25 MM). BACKFLOW PREVENTER SCHEDULE EQUIP.TAG LOCATION AREA SERVED MANUFACTURER / MODEL SIZE TYPE BA-1 DISHWASHER KITCHEN WATTS SERIES 009 2" RPBA City Of Edmonds Building Department Work PLUMBING FOR NEW RESTAURANT Address 22931 HWY 99 ------------------------------------ Owner HARVEST WONTON NOODLE Approved Date' 4-19-2021 Building Official Elr�41 CO-rfe-r Permit Number BLD2021-0430 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE EXPANSION TANK SCHEDULE TANK EQUIP.TAG MANUFACTURER / MODEL CAPACITY (GAL.) SYSTEM VOLUME (GAL.) STORAGE VOLUME (GAL.) SYSTEM TEMP. (°F) SUPPLY PRESSURE (PSI) T&P RELIEF (PSI) TANK SIZE, IN SYSTEM DIAMETER (IN.) HEIGHT (IN.) ET-1 AMTROL / ST-70VC 34 435 300 140 80 150 16 45 BLDG HOT WATER GAS WATER HEATER SCHEDULE RECOVERY UNIFORM TLKIV rLPOr.ITV IAIDTFR r nnlnlFr.TInKio INPUT F. H. ENERGY THERMAL THERMOSTAT EQUIP.TAG LOCATION MFG /MODEL NUMBER Btu/h 10 FACTOR EFFICIENCY TYPE DEGREE F (UEF) GALLONS LITERS HOT AND COLD INLET OUTLET RISE** EHW-1 KITCHEN RHEEM #XG75T06ST76UO 75.1 3 0.62 80% 75 284 IMMERSION 2 - 1/2" 2 - 1/2" 75 GALLON needs in premise isolation GENERAL NOTES 1. CONTRACTOR SHALL VISIT JOB SITE, VERIFY FIELD CONDITIONS, REVIEW PLAN AND SPECIFICATIONS AND SHALL INCLUDE IN HIS PRICE THE NECESSARY COST TO CONSTRUCT THIS PROJECT IN ACCORDANCE WITH THE MECHANICAL DRAWING AND SHALL MEET ALL APPLICABLE CODES. 2. ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED SHALL BE NEW, FREE FROM DEFECTS AND SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE OWNER. SHOULD ANY TROUBLE DEVELOP DURING THE PERIOD DUE TO FAULTY WORKMANSHIP OR MATERIAL, THE CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIAL AND LABOR TO CORRECT THE TROUBLE WITHOUT COST TO THE OWNER. 3. CONTRACTOR IS TO REVIEW THE PLANS OF OTHER DISCIPLINES AND COORDINATE WITH THE WORK OF OTHER TRADES PRIOR TO INSTALLATION TO AVOID ANY CONFLICT BETWEEN DUCTS, CONDUITS, SPRINKLERS, PIPING, LIGHTING FIXTURES, ETC. NO EXTRAS WILL BE ALLOWED FOR CORRECTION OF CONFLICTS DUE TO LACK OF COORDINATION. 4. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION OF PIPING, DUCT WORK OR DIFFUSERS. 5. THE CONTRACTOR SHALL BRING TO THE ARCHITECT'S ATTENTION OF ANY DISCREPANCY OR CONFLICTS IN THE PLANS OR THE SITE CONDITIONS. ALL NECESSARY CHANGES MUST BE APPROVED IN WRITING BY THE ARCHITECT BEFORE START OR WORK. 6. CONTRACTOR TO SUBMIT CATALOG CUT SHEETS OF ALL THE MATERIAL AND EQUIPMENT TO BE USED AND WORKING SHOP DRAWINGS FOR APPROVAL BEFORE START OF WORK. 7. SUPPORTS FOR ALL PIPING AND DUCTWORK SHALL BE IN ACCORDANCE WITH LATEST SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OR MECHANICAL SYSTEMS AND PLUMBING SYSTEMS" GENERAL NOTES 1. PROVIDE ISOLATED COUPLINGS AND/OR UNIONS AT POINTS OF CONNECTION BETWEEN COPPER, STEEL AND BRASS PIPING. 2. ALL WATER PIPING SYSTEMS AND DRAINAGE PIPING SYSTEMS, INCLUDING SUPPLY, WASTE AND DRAIN SHALL BE INSTALLED WITH VIBRATION ISOLATORS AND SHALL BE ISOLATED FROM ANY STRUCTURAL MEMBERS, WALL SECTIONS OR OTHER MATERIALS THAT COULD TRANSMIT SOUND TO THE OCCUPIED AREAS. ALL HANGERS, STRAPS, BRACKETS, AND SUPPORTS SHALL HAVE ACOUSTICAL COMPONENTS OR COMBINED NEOPRENE AND PLASTIC FOAM BY TECH SPECIALTIES, DIVISION OF SPECIALTY PRODUCTS CO. TO ISOLATE COMPLETE PIPE CONTACT AREA. ALL ISOLATION MATERIAL SHALL HAVE A MINIMUM THICKNESS OF 1/2". INSTALL ALL COMPONENTS AS PER MANUFACTURER'S INSTRUCTIONS. 3. INSTALL ALL CLEAN -OUTS WHERE REQUIRED BY ORDINANCES, AT ENDS OF HOUSE DRAINS, AT ALL CHANGES IN DIRECTIONS, IN ALL STRAIGHT RUNS AT 50 FOOT INTERVALS, WHERE HORIZONTAL MAINS CHANGE SIZE, AND AT ALL ENDS OF ALL BRANCH PIPES WHICH ARE 5' OR OVER IN LENGTH. ADDITIONAL CLEAN -OUT SHALL BE PROVIDED IN DRAINAGE LINE FOR EACH AGGREGATE HORIZONTAL CHANGE OF DIRECTION EXCEEDING 135' 4. PLUMBING FIXTURES SHALL BE COMPLETED WITH ALL ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION 5. SELECTION OF FAUCETS AND FITTINGS SHALL AVOID THE TYPE WITH POTENTIAL FOR LEAD CONTAMINATION. 6. INSTALL STOP VALVES ON HOT AND COLD WATER SUPPLIES TO EACH FIXTURE. 7. ALL FLOOR DRAIN MUST HAVE 1/2" COLD WATER LINE CONNECTED TO TRAP PRIMER. ALL UNDERGROUND COLD WATER LINE SHALL BE ASTM TYPE-K HARD DRAWN COPPER INSTALLED WITH CONTINUOUS SLOPE TOWARD FLOOR DRAIN. 8. MATERIALS, METHODS AND LOCATIONS OF SERVICE MAINS CONNECTING THE NEW CONSTRUCTION TO ALL NEW AND EXISTING SERVICES SHALL BE IN STRICT ACCORDANCE WITH RULES, REGULATIONS, CODES AND REQUIREMENTS OF ALL AGENCIES HAVING JURISDICTION OVER THIS INSTALLATION. LOCATE ALL EXISTING STUBS TO BE CONNECTED TO IN THIS CONTRACT BEFORE WORK IS STARTED. COORDINATE LOCATION OF WATER AND SEWER CONNECTIONS WITH BUILDING ENGINEER. 9. CAULK AIRTIGHT ALL PLUMBING PENETRATIONS IN SOUND RATED WALLS AND FLOOR/CEILINGS. SEAL PENETRATIONS OF CONCRETE FLOORS WITH CEMENT GROUT. MINIMIZE PENETRATIONS THROUGH SOUND RATED CONSTRUCTION. 10. CONTRACTOR SHALL INSTALL ALL PLUMBING FIXTURES AND TRIM AS SHOWN ON THE ARCHITECTURAL PLANS. ROUGH -IN FOR ALL FIXTURES SHALL BE EXACTLY TO MEASUREMENTS FURNISHED BY FIXTURE MANUFACTURER. ALL EXPOSED PARTS TO BE CHROMIUM PLATED UNLESS SPECIFIED OTHERWISE. 11. KEEP ROUGH -IN CUTS WITHIN THE PLATE LINES AND DO NOT CUT COMPLETELY THROUGH PLATES IN SOUND -RATED WALLS. DRILL OR SAW NEAT ROUND HOLES FOR ALL PIPING. SIZE APPROXIMATELY 1/2 INCH LARGER THAN THE PIPE DIAMETER. 12. PIPE LINES SHALL BE INSTALLED FREE FROM TRAPS AND AIR POCKETS AND TRUE TO LINE AND GRADE WITH SUITABLE SUPPORTS PROPERLY SPACED. PIPING SHALL BE INSTALLED WITHOUT UNDUE STRESSES AND WITH PROVISION FOR EXPANSION AND CONTRACTIONS. 13. HORIZONTAL LINES SHALL HAVE HANGERS OR SUPPORTS SPACED AS FOLLOWS: A. CAST IRON PIPE - 5' CENTERS B. STEEL PIPE - 10' CENTERS C. COPPER TUBING - 5' CENTERS FOR 1-1/2" AND SMALLER, 10' CENTERS FOR 2" AND LARGER 14. PIPING SHALL BE NEW AND FREE FROM FOREIGN SUBSTANCES. REAM OUT ALL BURRS FORMED IN CUTTING PIPE. THREADS SHALL BE CUT ACCURATELY AND NOT OVER TWO THREADS SHALL SHOW BEYOND THE FITTING. FRICTION WRENCHES SHALL BE USED WITH PLATED POLISHED, OR SOFT METAL PIPING. 15. CHANGES IN PIPE SIZE SHALL BE MADE WITH REDUCING FITTINGS, AND BUSHING WILL NOT BE PERMITTED. 16. UNION CONNECTION SHALL BE INSTALLED DOWNSTREAM OF ALL VALVES. AT ALL EQUIPMENT CONNECTIONS AND AT OTHER POINTS AS REQUIRED. 17. DO NOT ALLOW THE PIPING, VALVES OR CONNECTORS TO FORM A RIGID CONNECTION WITH THE STRUCTURE OR OTHER PIPES. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, JOINTS OR CONNECTED EQUIPMENT. 18. PROVIDE SIOUX CHIEF WATER HAMMER ARRESTER FOR EACH PLUMBING FIXTURE BANK OR 18" HIGH AIR CHAMBER FOR EACH PLUMBING FIXTURE. SIZE OF WATER HAMMER ARRESTER SHALL BE SUFFICIENT TO HANDLE THE REQUIRED FIXTURE UNIT AT EACH BANK. 19. THE DOMESTIC WATER SUPPLY AND DISTRIBUTION SYSTEM WITHIN THE AREA OF WORK SHALL BE STERILIZED WITH CHLORINE IN SOLUTION IN ACCORDANCE WITH AMERICAN WATER WORKS ASSOCIATION PUBLICATION C-601-1954. 20. PRESSURE TEST ENTIRE HOT AND COLD PIPING AND DRAINAGE SYSTEM FROM CAPPED CONNECTIONS, TO AND INCLUDING VENTS. 21. ALL DOMESTIC WATER LINE, FIXTURES, AND FITTING SHALL BE LEAD-FREE AND AB-1953 COMPLIANT. 22. PROVIDE ACCESS PANEL FOR ALL STUB OUTS ENDED INSIDE CEILING OR WALL. 23. THREADED FITTINGS: ANSI/ASME B16.3 BLACK MALLEABLE IRON. 24. SOCKET -WELDING FITTINGS: ANSI 316.11 FORGED STEEL. 25. BUTT -WELDING FITTINGS: ANSI/ASME 316.9 WROUGHT STEEL WITH BACKING RINGS OF COMPATIBLE MATERIAL. 26. UNIONS: ASME/ANSI 316.39 BLACK MALLEABLE IRON. 27. FLANGES AND FLANGED FITTINGS: ASME/ANSI B16.5 STEEL FLANGES OR CONVOLUTED STEEL FLANGES. FLANGE FACES SHALL HAVE INTEGRAL GROOVES OF RECTANGULAR CROSS SECTION WHICH AFFORD CONTAINMENT FOR SELF -ENERGIZING GASKET MATERIAL. 28. THREADED JOINTS: WHERE POSSIBLE USE PIPE WITH FACTORY -CUT THREADS, OTHERWISE CUT PIPE LENGTHS ACCORDINGLY WITH ANSI/ASME 31.20.1. PROVIDE THREADS SMOOTH, CLEAN, AND FULL -CUT. APPLY ANTI -SEIZE PASTE OR TAPE TO MALE THREADS PORTION. WORK PIPING INTO PLACE WITHOUT SPRINGING OR FORCING. BACKING OFF TO PERMIT ALIGNMENT OF THREADED JOINTS WILL NOT BE PERMITTED. ENGAGE THREADS SO THAT NOT MORE THAN TWO THREADS REMAIN EXPOSED. USE UNIONS FOR CONNECTIONS TO VALVES, METERS FOR WHICH A MEANS OF DISCONNECTION IS NOT OTHERWISE PROVIDED 29. WELDED JOINTS: WELD BY THE SHIELDED METAL -ARC PROCESS, USING COVERED ELECTRODES AND IN ACCORDANCE WITH PROCEDURES ESTABLISHED AND QUALIFIED IN ACCORDANCE WITH ASME B31.8. 30. FLANGED JOINTS: USE FLANGED JOINTS FOR CONNECTING WELDED JOINT PIPE AND FITTINGS TO VALVES TO PROVIDE FOR DISCONNECTION. INSTALL JOINTS SO THAT FLANGE FACES BEAR UNIFORMLY ON GASKETS. ENGAGE BOLTS SO THAT THERE IF COMPLETE THREADING THROUGH THE NUTS AND TIGHTEN SO THAT BOLTS ARE UNIFORMLY STRESSED AND EQUALLY TORQUE. 31. USE TEST PRESSURE OF 50 PSIG. DO NOT TEST UNTIL EVERY JOINT HAS SET AND COOLED AT LEAST 8 HOURS AT TEMPERATURES ABOVE 50 DEGREES F. TEST PIPING SYSTEM FOR AT LEAST 4 HOURS WITHOUT PRESSURE LOSS OR VISIBLE LEAKS. 32. PLUMBING FIXTURE CONNECTION SIZE: SEE PLAN. 33. SANITARY AND GREASE DRAINAGE PIPING AND FITTING: A. CAST IRON SOIL PIPE AND FITTINGS (ABOVE FLOOR): REQUIRED CISPI 301 & 310 WHICH COMPLIANCE WITH HUD UM 77A CAST IRON HUBLESS SOIL PIPE AND FITTING. ALL PIPE AND FITTINGS SHALL BE MARKED WITH CISPI'S COLLECTIVE TRADEMARK OR RECEIVE PRIOR APPROVAL BE THE ENGINEER OF RECORD. JOINTS FOR HUBLESS PIPE AND FITTINGS: CISPI 310 AND SHALL CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND LOCAL CODE REQUIREMENTS. ANACO "HUSKY SD 4000, CLAMP -ALL 125, TYLER WB, MG COUPLINGS, OR EQUAL, COMPLY WITH FM 1680, CLASS 1. B. CAST IRON SOIL PIPE AND FITTINGS (BELOW SLAB): ASTM A74 STANDARD WEIGHT HUB AND SPIGOT PIPING AND FITTING. ALL PIPE AND FITTINGS SHALL BE MARKED WITH CISPI'S COLLECTIVE TRADEMARK OR RECEIVE PRIOR APPROVAL BE THE ENGINEER OF RECORD. JOINT FOR HUB AND SPIGOT PIPE AND FITTINGS: ASTM C-564 COMPRESSION GASKETS OR SHALL BE INSTALLED WITH LEAD AND OAKUM. C. COPPER DRAINAGE PIPING AND FITTINGS (ABOVE FLOOR): ASTM B306 DWV TYPE COPPER TUBING AND ANSI B16.23 CAST BRONZE SOLDER -JOINT DRAINAGE TYPE FITTING. PROVIDE MISSION, OR EQUAL, CISPI 310 ADAPTOR COUPLING WITH NEOPRENE GASKET AND STAINLESS STEEL SHIELD WITH TWO BANDS. D. CONDENSATE PIPING AND FITTINGS: ASTM B88 HARD DRAWN DEOXIDIZED, TYPE M COPPER TUBING WITH ANSI B16.22 WROUGHT COPPER WYES AND LONG RADIUS SOLDER -JOINT FITTINGS. 34. PRESSURE PIPING AND FITTING: A. DOMESTIC COLD AND HOT WATER (ABOVE GRADE): HARD DRAWN DEOXIDIZED WATER SERVICE TUBING CONFORMING TO ASTM B88, TYPE "L". PROVIDE 125 PSI FLANGE AT CHANGE OF MATERIAL LOCATIONS. B. DOMESTIC COLD AND HOT WATER (BELOW GRADE): HARD DRAWN DEOXIDIZED WATER SERVICE TUBING CONFORMING TO ASTM B88, TYPE TYPE "K". C. FITTINGS FOR COPPER WATER TUBING: ANSI B16.22 WROUGHT COPPER SOLDER -JOINT FITTING. D. TRAP PRIMER PIPING (UNDERGROUND): HARD DRAWN DEOXIDIZED WATER SERVICE TUBING CONFORMING TO ASTM B88, TYPE "K", WROUGHT COPPER FITTING AND BRAZED JOINT. F HARRIS FN(,FI HARn, nR EQUAL, BCUP FILLER MATERIAL FOR BRAZING OF COPPER FITTING JOINTS. BRAZE JOINTS FOR COLD WATER PIPING 2-1/2" AND LARGER. BRAZE JOINTS FOR HOT WATER PIPING 2-1/2" AND LARGER. 35. NATURAL GAS PIPING AND FITTING: A. BELOW GRADE PIPING: P= 2406, POLYETHYLENE PIPING CONFORMING WITH ASTM D2513, WITH SOCKET TYPE FITTINGS CONFORMING WITH ASTM D 2683, AND MINIMUM SDR 11. FOR 6" SIZE NATURAL GAS MAIN, USE BUTT FITTINGS WITH SDR 11. PROVIDE POLYETHYLENE TO SCH. 40 STEEL PIPE TRANSITION FITTING AND RISER AT EACH BUILDING PRIOR TO EXTENDING GAS PIPING ABOVE GROUND. PROVIDE 16 AWG COPPER TRACE WIRE OVER ENTIRE RUN OF PE PIPING AT 12 INCHES ABOVE PIPE. RL GAS CODE 2015 : 6.430 NOTE: QUALIFICA ERFORM WELDED GAS PIPE MUST BE�INACCD�RDANCE WITH THE SEATTLE GASSUB-NOTE: MINIMUM WELD CONSTRUCS REFERENCING THE 2015 SFGC TO EATTLE MUNICIPAL COD FAIT D E S I G N S T U D I O 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: INFORMATION REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 03/25/2021 SHEET# RECEIVED Mar 30 2021 I TY OF EDMONDS LOPMENT SERVICES DEPARTMENT LEGEND VTO VENT TO OUTSIDE BURIED PIPE DFU DRAINAGE FIXTURE UNIT SEWER M(N)FS FLOOR SINK GM GAS METER WSFU WATER SUPPLY FIXTURE UNIT _ GREASE WASTE LINE FD FLOOR DRAIN GW GREASE WASTE LINE (E) EXISTING ...... _,_, COLD WATER FFD�_] FUNNEL FLOOR DRAIN SS SANITARY SEWER LINE (N) NEW —HW—Hw HOT WATER SUPPLY �Fco FLOOR CLEAN OUT HW HOT WATER SUPPLY WATER HAMMER ARRESTER HOT WATER RETURN REDUCED PRESSURE CW COLD WATER SUPPLY RPBA BACKFLOW ASSEMBLY ................ VENT TO ROOF (VTR) POTABLE WATER RISER PLAN SCALE : 1!4" = 1-00" rl-R,•larr+ Gr 1f ! 1-A VIA �M C �r v�ti !414y pp ,J MATIll MCIP ENrIT," i kx-4 L- 3 LV il+i T u I I iL F'FP&8 TRAP SEAL PFMMER AE00MMENNO MWFA lAMON 3 TRAP SEAL PRIMER AUTOMATIC TRAP PRINTER VALVE. 11695 SERIES Rrim€Perfect' rrEM r 51U@MIT7EP aW RAME SPECIFICATION LOCA71DN Sil �N0( Fp $arms Prirn�3PrrrfPzVm trpp primer V-PlOPs shall Orr used Ir,IG+tI I R whcrg r,plii;nighmgnit 1�f water in fli7Qr drain trap'9 is required Trip primer vplvr , Shall be fir" r P inlet x W MIP %till AutornotiG trip primer val6i CONTIRAL70R shall aG#iujoe with a 10 PSIG preS!urQ drop betwewi 30-150 PSIC- Hod r Water release Shall be faii Set_ Trap pruner valve 911a1I horse large pert apenmgrs_ Trap prirrwr valve mall bi� UPC/IAPMO listed, and 1 E c#rtlfled to the ASS E 101J standard- I NSTALLATION ReplenishcEl; water in fluor drain traps to prevent e,5cape of Sewer gas. The nurrb%-r of traps serviced by arty trap primer is a function of aciNat'ill frequency and evaporation rate and shiauld be determined by the design engineer andlcr the installirlgcortractor. I nstall to a ih'-ice' ncminal weer lino, near the trdfpl to seryd- Invoil in the upright, vertical IgD"icn -Dnly. I n$Rell at least 6" above the grid of the flp(K drain K�r the flood rim of the fixture which the trap serves- InsiFil rear olumhr'ng fbtures to Insure a full preslsure drop of 10 PSI o? r"me. If the trap primer Is Installed t€c far a psiream in the system, the pressure drop may nat be enough for activation. Install a Vertical fooQthat uses above the supply Ilene tee, :see figure 1) Flush branch lime Drim tip instalthe trap prlr'1'rer. Install MIF adapter. Lcnnecl trap primmer. Install FIP union to i Use PTFE tap,& on bath canr)et5ons. i r,tt use pips dope. Do oat -,;tIder c r II directly bo trap primer a ftting,-, in�italled in trap primer. Water dischl is factor}, set—nn adl ustrnent is required fln normal wk,,retar 3-W, imstell"Lins. Fur static preEisures cvL:F 100 PSI, udjuis Affid nlay he Imp pini°' raoeg"ry. Fret Ir}n�Rn tl)R nipples lxknut i hal�ywj, then turn the nipples yiFPf (19. �aluw) Cuurltir-GlQckwit;e until the trap primer stars dripping, turn thtd liaar4rair nipple Glockwise14-ttrm to stop dripp'in_ and re tighten nipple 1GGknut- WORIII PRE +SURE 3C-250 PS10 Fig, 3 OPERATING PRESSURE AttivAit.�s will 10 1 pregAureu drop at 00-15C i 'el- nF COMPONENTS sit 1; dap 11; Vtrum hrealt�r 3 13 2: Stainless steel screlas 2.2: Sedlrniiiint screen r 1G $t plAlnri 13' aiaphr.Mm stop waShAr 5 yfi a- VeilVe stern !Sprtrtg 11- piephr Vm spring retainer $ 3T 7 5: wahre stem nut iR Vi stem a 8: ruby, variii alb 13, LkaCnragm WnM 3: Yrilrp sl Pre, giJide 17: V%lti'e washE+r lfl 6, Body 15; Diaphragm acllusrmant nut U: NIppla scat washer 29: crass nippy 1i 10: Nipple Iacknut 1 1i M IF SCALE: 4 TRAP SEAL PRIMER N.T.S. aiilir Made in USA INSTALL POINT OF USE "THERMOSTATIC" ELECTRICAL TANKLESS HOT WATER HEATER ACCUMIX II,SEE SPECSHEET ON P2 INSTALL POINT OF USE "THERMOSTATIC" ELECTRICAL TANKLESS HOT WATER HEATER ACCUMIX II,SEE SPECSHEET ON P2 42,r30. / y r��• 10 ww FUw' yoTtP A 4,? 30, 42?*30 19 19 0 00 (SIDE VIEW) 0 (TOP VIEW) SERIES 009 REDUCED PRESSURE ZONE ASSEMBLIES PREVENT THE REVERSE FLOW OF POLLUTED WATER FROM ENTERING INTO THE POTABLE WATER SUPPLY DUE TO BACKSIPHONAGE AND OR BACK PRESSURE. IT CONSISTS OF BRONZE BODY CONSTRUCTION (1/4 TO 2 IN., 8 TO 50MM) OR FDA APPROVED EPDXY COATED CAST IRON (2 1/2 TO 3 iN., 65 TO 80MM), TWO, IN -LINE INDEPENDENT CHECK VALVES, REPLACEABLE CHECK SEATS WITH AN INTERMEDIATE RELIEF VALVE, AND BALL VALVE TEST COCKS. SERIES 009 IS IDEAL FOR PROTECTION OF HEALTH HAZARD CROSS -CONNECTIONS OR FOR CONTAINMENT AT THE SERVICE LINE ENTRANCE. CHECK WITH LOCAL WATER AUTHORITIES FOR INSTALLATION REQUIREMENTS. MAXIMUM WORKING PRESSURE: 175PSI 12.06 BAR). 2 BACKFLOW PREVENTION SCALE: N.T.S. qT � �`? ws�• � `"w FRRFr� �w• C�, w`�"wsF 42X3p„ I I (4 "14jSFU "�•�1'4`(s �s "w `"w qkF I I r• "w�"w yoT'VATFR z� IJNOF�r zs I (�SwsFy� �w�4�8S "w�"w RFryRy R `• Cw rsFMq�FR2n ,, yy I I •���U `" �W �•` "�8 r p Nrr/VO ."NFq SF� ` \' 24 �Q o I •�• �(6�5� OF�rVF9yc �•�SFUJ gMTq<<wF�FNTFR9FF�0 CPF I I(rr�w RJ gBryF �. pFR MFgq TFR QOi - wSFU I : •�• t&TI, soy 10 9gFSTF i I I l E I C r� (14 • s Cal/lF yolWgP �, �� // 1 ,/ I /s" q FRR HF , 22 •"w�yIV r� FTURN F , 2r hs c i�2�2 ky Tq� NS ?o y \\ S oCk ��,�� pp2 � ♦,BUJ .�"w OT �gTF9 .; � , 15 11'0,yr 116 TRAP PRIMER �' `? /Zt .f Ri s , 1/2" COLD WATER LINE �. �" r� (GRAVITY) FROMTRAP PRIMERS / �. 4- �' •' I �� j Q / 2444. N PER 1007.1 UPCcFgpy� ��.3 •I i� _ ®yS SEE \ r TRAP PRIMER SPEC SHEET �0 � e Mr ONPAG P2 3 Qpx3oR �� ��Z���c� 14 wOR�TgB 3 r2 ti o� Q WATER HEATER RESTRAINT INSTALLA77CN INSTRUCTIONS. "C2.utiCsn: Mall covering may conceal electrical wiring cr pipes. which may cause damage er serlcus injury if punctured by drills or fastenars. Unless ycu are confident that there will be no interference from such obstacles, we reparnme"d Chat you seek qualif led help when installing this product. INSTALLER_ WEAR GLOVES AND PROTEC77VE EYFWE R IWNEIVINSTALUNG THIS PRODUCT. 'Caution: Strap caul is harder tensbn. DOX i.r OJ7 1 E l e 4 - Straps 4 - buckles 4 - Lag 1301ts %" K 2W Self -Drilling with 1/4" Flat Washem 2 - 31S" carriage bolts, washers, and nuts TOLLS NEEDED- ■ 3!8 Socket flu +illrench tar Ti h#ernn La Bolts at Wall 9 g 9 + WI-13" Winn dh tar Tighteniog Oam ge- Eml at uucklea * Optional- aril I with 118" Drill fait Salect water heater location against a wean stud wall. pasiti�ning directly in imnt of a 2" x 4" wall stud is stmr9ly recommended, and there must be a stud on each aide of the unit to anchorthe Wow. :4e FigivreA. Straps muvt be installed in the upper and 113 at the water haater body The lowier $trap musl be at " leav I" adavo the water heater. _ ccr}trpls. 5�9-9 Figure 8. Mark the wall studs on both sides of the water heater where you will ❑ " ,stall the straps. Drill 118" pilot » h0lea If slash$-i First Strap pair assembly (select either high or law positiar]. SeleG1 one Strap, and tempnratily install ono suckle per Figure EI & E2:51rap " A'J, Without handing the Strap beak. See Figure E3, Hold strap "A' so the Suckla ism the approximate front -center of the water healer See Figure 6. select a mounting hole a# the other end W the Strap that best aligns to Un4 pllljt Fnatk Ors thb ikCr d. (Nbtb: A115W A A -light 191ASil:611 rats -Ter than slack when molectir>rg the mounting hole.) If narassary, re- position the 131.1ckle and ra-allgr . secure the and of tha Strapio the %tud with at !4" x 2Yi" belt and was# er. See FrQur� . • nztaII Strap l3" [S Figurb Q O, ) the ❑ ppvsit-0 side of ° the haater per Ste [ Fr_4ryre 0, & E I-0) mhowa. Selwi the muuntiny hulas rhioh •lace U1-a . �ucf4le a# th o x= front -canner of rho- water heater while aligning with the pilot mark an the second stud. It is important that, with the Straps piAl!I0 tightly ",gTher araund the wratar haater, the bankles must end up approximately 2'Y2- - 31` aparl. ;i the bunkla and wall mnunling hales accordingly_-5eaure Strap "B" to the second wall stud as above, Send the Strap ends that pass Through the Buckles agains# the back side of the Buckles, so iheyy will press against the water heater Will when secured Pvu AiLrre E9). S6('ura the twi5 113urkl$s I006thbr rlilh W ;carriage boll, nut and washer, and tightest (See Figure F). Second Burp pair =s vrT*iy: Repeat steps 2 - 4 for the second pair of Straps. Although spill the same h01a srd slat positions as in the first installation hi 1ikelytc work, in sgme uses it r"-ay bl} rwcessary W slightly repQaiftn the Buckle or wall mount. H naoessary, tam Strap I` ends at we wail. Installation curnpiele. Q r r 99 / r �/N ',` � �' 401, 3 9 Z� J 0 �3 ;V�e� s3i y m ��F_ �ipX3oR OaJ�O/ rN3 � Q l pF411f q wgTFR R 609 r (9, STFh' PRODUCT SPECIFICATION DRAWING QUICK STRAP® #QS-50 Seismic support for water heaters HOT WATER SUPPLY TOTAL = 20 WSFU / 1" COLD WATER SUPPLY TOTAL = 32 WSFU / 1 112" RECIRC PU / i SHUT-OFF VALVE CONNECT TO EXISTING 2" WATER INCOMING LINE VERIFY EXACT LOCATION BY CONTRACTOR HOT WATER RECIRCULATED PER THE ENERGY CODE C404.7.1 OF THE WASHINGTON STATE ENERGY CODE. HOT WATER TANK (75 GALLON) RHEEM #XG75T06ST76UO (SEE SPEC SHEET P4) Maintain service area clearances �o 1 1 i 2" I C C O U C O C C 0 l C C 0 o e. o. ALL DIMENSIONS IN INCHES J-Chp Carriage Etcl;, #3B-16 x 3.0" long 318" Hex Nut Lag Bolt, #114.10 x 2-172" Lpng The QUICK STRAP® #QS-50 is a seismic/earthquake support system for water heaters up to 80 U.S. gallons in size. The system includes: (4) Straps, (4) Lag Bolts, (4) J-Clips, (2) 318" Carriage Bolts and (2) 3I8" Hex Nuts. The Quick Lini system allows for full adjustment from the front side of the water heater. B�� o Product Information: pC METHOD • Material: Strap, 24 gage CRS, galvanized Nu.97M • California Division State Architect (DSA) approval "7-010 • UPC 1 IPC 1 EAPMO listed TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. NOL0 T 0 CCNi+ERTING'•.IAKE'JHFTt.Er-CDB R11,1E'4GINEEU03ULJT3Ne•' 600-321-0316 OR 760.744-6944 1 FAX 760-744-0507 1 WWW,HOLDRaE.COM spec_QS-50_RevK 4" VENT STACK UP TO ROOF w/WEATHER VENT CAP GATE VALVE (TTP.) TERMINATION AT 3ABOVE ROOF AND 11 FROM AIR SHUT - OFF VALVE COND. UNIT OSA INTAKE (UPC 517.0) 3/4" HW TO FIXTURE COMBINATION ----------------------- TEMPERATURE &PRESSURE RELIEF VALVE 3/4" (OR SAME SIZE AS RELIEF VALVE OUTLET) COPPER DRAIN T & P DISCHARGE TO MOP SINK OR OUTSIDE OF BUILDING GAS SUPPLY GAS LOCK SEDIMENT TRAP AUXILIARY CATCH PAN NOTE: PROVIDE PRESSURE REDUCING VALVE IF GAS PRESSURE IS HIGHER THAN HEATER RATING. 1-------------- ------4--------- - THERM-X-TROL THERMAL EXPANSION TANK, "AMTROL"ST-12 (4.4GAL.) OR " WILKINS"WXTP-18 (4.5GAL.) OR APPROVED EQUAL APPROX. 5 GALLON UNION - TYP. TEMPERATURE AND J;PRESSURE RELIEF VALVE `; QUICK STRAP #QS-120 WITH CARRIAGE BOLT, 8"-16x 3.0" LONG, LAG BOLT 4"-10 x 2-1/2" � LONG , 8" HEX NUT AND L-CLIP CI = DRAIN VALVE M DRAIN PAN PIPE TO SUITABLE DRAIN 1 I GAS WATER HEATER INSTALLATION AccuMix 117M Thermostatic Heater Ideal for Sensor or Metering Faur ets - UPC 407.3 Compliant Applications • Hardwashing • Lava-ory sinks • Kitcherdbadutility sinks • Ideal for sensor or merering faucets speeffications Ell Tar'1C55'r4+a:cT ice', 12 Performance Features • Integrated mixing valve meers ASSE 1070. • Unc meets UPC 407,3 requirements when properly installed e • Self diagnostics with intelligent corrmis actively protect heater in installed environment • Sa€eSlartTM technology engages upon start-up to help avoid dry fire occurrence • Law actNntlor. with C.3 GPM turn on flow • nigital LEG display corm,, ica-as system status and heater operation teedback • Silent operation on all models except for RMU1224UT c��s o :.:* � ii-1 r C �� u5 (] aurae"'" liltll� • Mounts in any orientation for a lexible installation LISTED LESf • Oampactsizefits almt7SlP.wwhp.m;sAFblefor ADAcompliant aLIST,;,,,,.;_.�rrnrthnXr�rrswBhin�rTnlrnf•,nirri,r��irxl,rnn-rr,m�rrt�triirFr ntin facilities • Only one input line, hct or cold, needed Ear an easy Iratallatiar • Designed to deliver hot water to a single pipe faucet or Suggested Specification mixing faucets Tankless water healer Shall he an Eemax Accumix II model • Integral 318' Compressan flttings; nc sDldering or sweat number AM connections required Unit shall have ABS-UL W-5VA rated cover. Unit shall have 0.3 • No T&P relief valva needee (check local codes); Ready to go. GPM turn on. Unit shrill allow nr iog in arty direction. Uses right ant-o -ThP.-b Ox ASSE 1070 approved intr�yralrtd ,nixing valve to confgrn� to • Save lva Pr Hnd time by instHlhny nnil at fhH FlAnt-of-usri UPC 4C7,3. Element shall be replaceable cartridge insert. Unit • CAA rol system activates heater only on demand shall have replac:eahle filter in the neat cgnnertgr. ElHrreni shHll • lerrperature limit s enehles safe operation he iron free, Nickel Chrome material, Tankless seater healer to Ai% ent • A^tive energy manage rant rv'rh power mnri,ila ion allows for utiiize cumplex alporithm, actively managing power application thermostatic accuracy to real time system demand Integrated flow meter. along with • 5-year limited warranty on leaks, 1-year on parts inlet and cutlet temperature sensors provide data Which allows the unit to Instantly adapt to variations In input parameters. PraductSpetdfieatians Heater sFiall be fitted with 3/8' compression fittings to eliminate Dimensii 13.75' H x 5.;5 W r 4') need for soldering. Maximum operating pressure of 150 PSI. Weight 6 it Diagnostic teatures to. include error4auft display, Hot water Cover: PBS-UL 94-�,A sturage larks prohibited, Unit sltell be Eamax or approved Color: 'NWIL equal. Temperature: Fa.lcry5et.-:e 10S'F Min. Dynamic Operating Pressure: 35 P:I Max. Dynamic Operating Pressure: 155 P,I Element REplscf31ble nichromrt �WdgE hmrt FRUnrs: 3i8' cxtplMdunfinn-40 UL IlsW file number. 1:95887 US PaLcni Perdinc 7,chrnlav Special Design service Inquirios for units for cnicue applications are wlelco ne. Call ourTechnical Ser%ice department at 1-800-543-61 G3 5 (U,P.CL:', REQUIRES ASSE 1070 MIXING VALVE) SCALE N.T.S. PORTABLE WATER: COLD WATER (BASE UPON 2015 UPC) QT. PIPE SIZE F/U EACH F/U TOTAL FIXTURE NAME 3 1/2" 2 6 HAND SINK 1 3/4" 3 3 MOP SINK 1 1/2" 2 2 FAUCET (WOK) 1 1/2" 2 2 FAUCET (STORK POT) 2 1/211 2 4 FAUCET (NOODLE STEAMER) 1 1/2" 2 2 1 COMP. SINK (VEG) 1 1/2" 2 2 1 COMP. SINK (MEAT) 1 1/2" 2 2 3 COMP. SINK 1 1/211 2 2 ICE MAKER 2 1/2" 1 2 LAVATORY 2 1/211 2.5 5.0 TOILET 32.0 TOTAL OF WATER SUPPLY F/U PORTABLE WATER: HOT WATER (BASE UPON 2015 UPC) QT. PIPE SIZE F/U EACH F/U TOTAL FIXTURE NAME 3 1/2" 2 6 HAND SINK 1 1/2" 1 1 TEA HOT POT 1 3/4" 3 3 MOP SINK 1 1/2" 2 2 1 COMP. SINK (VEG) 1 1/2" 2 2 1 COMP. SINK (MEAT) 1 112" 2 2 3 COMP. SINK 1 1/2" 4 4 DISH WASHER 20.0 TOTAL OF WATER SUPPLY F/U @FAJ D E S I G N S T U D I O 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: POTABLE WATER RISER PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 03/25/2021 SHEET# RECEIVED Mar 30 2021 2TY OF EDMONDS LOPMENT SERVICES DEPARTMENT � o V 4 h� �� / v N Z � , Q y 001 i i �J HYDROMECHANICAL GREASE INTERCEPTOR(HGI) SIZING CHART DFUs HGI FLOW (GPM) 8 20 10 25 13 35 50 20 35 75 172 100 216 150 342 200 428 250 NON -GREASE LINE (BASE UPON 2015 UPC) QT. SZEP EACH TOTAL FIXTURE NAME 3 2" 2 6 HAND SINK 1 2" 2 2 FLOOR SINK (1 COMP SINK :VEG) 1 2" 2 2 ICE MAKER 1 2" 4 4 DISH WASHER 14 TOTAL OF DRAINAGE F/U WASTE LINE TO GREASE INTERCEPTOR (BASE UPON 2015 UPC) QT. SZEP F/U EACH F/U TOTAL FIXTURE NAME 1 3" 3 3 MOP SINK 1 2" 2 2 FLOOR SINK (WOK) 2 2" 2 4 FLOOR DRAIN 1 2" 3 3 3 COMPARTMENT SINK 1 2" 2 2 FLOOR SINK (1 COMP SINK: MEAT) 14 TOTAL OF DRAINAGE F/U SANITARY SEWER LINE (BASE UPON 2015 UPC) QT. SZEP EACHOTAL FIXTURE NAME 2 2" 1 2 LAVATORY 2 2" 4 8 TOILET 10 TOTAL OF DRAINAGE F/U 42�1'3p„ 42X3 p 00 2 2" VENT# 3 .1 oa ;� a WALL CLEAN -OUT � � v N00 � 8Te4 �F 6sX3QF9 �i 2" VENT WALL CLEAN -OUT ` 1 • 1 1 1 , Y ' 1u 1 ;12 42%I'3p„ �12�� " 1 11 2 Q/� F . ' 1 AFC/� -.••• F9y0gB�NFTgX1 ; zr 3p„ 20 `v 18 9 18 1P0 OP /4" PEh FOOT 9yF r1� TRAP SEAL PRIMERS TO FLOOR DRAINS PER 1005.1 AND 1007.1 SPC WASTE AND VENT PLAN — 6? i ri,ill Illluu. .' I• `ram IIIC�6D III SCALE: 1 /4" = 1'- 0" LEGEND VTO VENT TO OUTSIDE BURIED PIPE DFU DRAINAGE FIXTURE UNIT dO FS FLOOR SINK GM O GAS METER WSFU WATER SUPPLY FIXTURE UNIT FDO FLOOR DRAIN GW GREASE WASTE LINE (E) EXISTING FFD� FUNNEL FLOOR DRAIN SS SANITARY SEWER LINE (N) NEW zFco FLOOR CLEAN OUT HW HOT WATER SUPPLY WATER HAMMER ARRESTER —4qHF�— REDUCED PRESSURE OW COLD WATER SUPPLY RPBA BACKFLOW ASSEMBLY PLUMBING NOTES: ALL POTABLE WATER PIPINGS ARE PEX PIPE. WATER PIPES INSTALLED IN THE ATTIC OR EXTERIOR LOCATION MUST BE HEAT TRACED AND INSULATED. EXTERIOR LOCATIONS WHICH ARE HEAT TRACED AND INSULATED REQUIRE METAL JACKET WITH GROUND FAULT PROTECTION AND ELECTRICAL INSPECTION. "ALL HEAT TRACING REQUIRES GROUND FAULT PROTECTION." -PIPING PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE PROTECTED IN ACCORDANCE WITH REQUIREMENTS OF THE BUILDING CODE, APPLICABLE STANDARDS REFERENCED IN UPC TABLE 14-1. SEE SECTION D5 BELOW FOR MORE DETAILS -SLEEVE PLUMBING PIPES AT CONCRETE/MASONRY SLABS, WALLS, OR FOOTINGS WITH PIPE SLEEVE, PACKING FOAM SHEETING, BUBBLE WRAP OR EQUAL. -INSTALLATION REQUIREMENTS FOR PLUMBING FIXTURES. -THE CLEAR SPACE IN FRONT OF ANY WATER CLOSET OR BIDET SHALL NOT BE LESS THAT 21 INCHES. -HOT WATER DELIVERED FROM PUBLIC USE LAVATORIES SHALL BE LIMITED TO A MAXIMUM TEMPERATURE OF 120 DEGREES F BY A DEVICE THAT CONFORMS TO ASSE 1070 OR CSA B125.3. THE WATER HEATER THERMOSTAT SHALL NOT CONSIDERED A CONTROL FOR MEETING THIS PROVISION. -WATER HEATER REQUIRES SEISMIC STRAPS AT UPPER/LOWER 1/3 OF THE TANK. (SEE WWW.MYBUILDINGPERMIT.COM TIP SHEET #007) FOR NON-RESIDENTIAL INSTALLATIONS ,ENGINEERING IS REQUIRED FOR SEISMIC BRACING ON EQUIPMENT EXCEEDING 75# WHEN MOUNTED OVER 4FT ABOVE FLOOR LEVEL, CEILING MOUNTED OR WALL MOUNTED, AND REQUIRED FOR EQUIPMENT EXCEEDING 400# MOUNTED LESS THAN 4FT ABOVE FLOOR LEVEL. (SEE COB POLICY & PROCEDURE IBC 06-003 FOR ADDITIONAL DETAILS) -HEATED-WATER CIRCULATION SYSTEMS SHALL BE PROVIDED WITH A CIRCULATION PUMP. THE SYSTEM RETURN PIPE SHALL BE A DEDICATED RETURN PIPE OR A COLD WATER SUPPLY PIPE. CONTROLS FOR CIRCULATING HOT WATER SYSTEM PUMPS SHALL START THE PUMP BASED ON THE IDENTIFICATION OF A DEMAND FOR HOT WATER WITHIN THE OCCUPANCY. THE CONTROLS SHALL AUTOMATICALLY TURN OFF THE PUMP WHEN THE WATER IN THE CIRCULATION LOOP IS AT THE DESIRED TEMPERATURE AND WHEN THERE IS NO DEMAND FOR HOT WATER. -POTABLE WATER SUPPLY TO CARBONATORS REQUIRES A REDUCED PRINCIPLE BACKFLOW PREVENTER WITH APPROVED PIPE (NOT OF COPPER, COPPER ALLOY, OR OTHER MATERIAL AFFECTED BY CARBON DIOXIDE) INSTALLED DOWNSTREAM OF THE RP. SEWER GREASE WASTE LINE ------. COLD WATER —HW-Hw— HOT WATER SUPPLY HOT WATER RETURN ---------- VENT TO ROOF (VTR) 3" VENT .r 1 • 1 'i. 1 � 1 ,1 21 1 1 1 ;12„ 1 1 1 4 n.74`l 1 NOTE 418.5 UPC : FLOOR SLOPE FLOORS SHALL BE SLOPED TO FLOOR DRAINS. 1005.1 UPC : TRAP SEAL EACH FIXTURE TRAP SHALL HAVE A LIQUID SEAL OF NOT LESS THAN 2 INCHES (51 MM) AND NOT MORE THAN 4 INCHES (102MM), EXCEPT WHERE A DEEPER SEAL IS FOUND NECESSARY BY THE AUTHORITY HAVING JURISDICTION. TRAPS SHALL BE SET TRUE WITH RESPECT TO THEIR LIQUID SEALS AND WHERE NECESSARY, THEY SHALL BE PROTECTED FROM FREEZING. 1007.1 UPC : FLOOR DRAIN TRAP FLOOR DRAIN OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM AND SUBJECT TO INFREQUENT USE SHALL BE PROTECTED WITH A TRAP SCAL PRIMER, EXCEPT WHERE NOT DEEMED NECESSARY FOR SAFETY OR SANITATION BY THE AUTHORITY HAVING JURISDICTION. TRAP SEAL PRIMERS SHALL BE ACCESSIBLE FOR MAINTENANCE. 609.10 UPC: WATER HAMMER BUILDING WATER SUPPLY SYSTEMS WHERE QUICK -ACTING VALVES ARE INSTALLED SHALL BE PROVIDED WITH WATER HAMMER ARRESTER(S) TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF THESE VALVES. WATER HAMMER ARRESTERS SHALL BE APPROVED MECHANICAL DEVICES IN ACCORDANCE WITH ASSE 1010 OR PDI-WH 201 AND SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO QUICK -ACTING VALVES. C403.2.9 WSEC PIPING INSULATION ALL PIPING SERVING AS PART OF A HEATING OR COOLING SYSTEM SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH TABLE C403.2.9. RrAS Weir NOTE: TO INTERCONNECT 3 COMPARTMENT SINK DRAINS, I THEY MUST BE CENTER CONNECTED USING A FIGURE 50 FITTING. (TRAP AND VENT ARE REQUIRED) iu. 6 TRIPLE COMPARTMENT SINK 2" V ENT 1 1 1 I 1 1 1 1 1 ;12„ ; 1 1 1 1 1 11 2 1 1 1 1 SANITARY SEWER LINE TOTAL = 10 DFU / 3" CONNECT TO EXISTING SANITARY SEWER LINE (FIELD VERIFY EXACT LOCATION BY CONTRACTOR) NON -GREASE LINE TOTAL = 14 DFU / 3" CONNECT TO EXISTING SANITARY SEWER LINE (FIELD VERIFY EXACT LOCATION BY CONTRACTOR) NEW GREASEINTERCEPTOR SCHIER G132 / 50 GMP SEE DETAIL ON PAGE P5 2 � O� AT40 OFPTF 1 CIO[�SRFlO eF�OW �1 M 1 1j Q Z 0 <Z) oo Z a Q- M cf Q CO s �Q" Dip 8 TRAP SEAL GREASE LINE TOTAL = 14 DFU / 3" CONNECT TO EXISTING GREASE INTERCEPTOR (FIELD VERIFY EXACT LOCATION BY CONTRACTOR) Depth of Tray Seal Mdn. Try 2 inures (51 mnl) Max. IF-ap Sand, inchaS (1621r1m} WASTE MANIFOLD BY CONTRACTOR WITH 2" LINE DUMPING TO GREASEINTERCEPTOR OM 4L _ 4 a 1 ma "L%7. I 9rallMAII' R YW WAL AFV GEEP')UL _.'W W SCALE : SCALE N.T.S. RAISED CURB (IF ANY) FINISHED FLOOR CONC.SLAB RAISED CURB (IF A 2111. 1'-0" 1.2 VERIFY TO COMPLY W/ LOCAL FLOOR SINK —"P" TRAP CODE REGULATIONS CONDENSATE DRAINS FROM FOOD STOREROOMS. WALK-IN FREEZERS AND COOLERS, AND REFRIGERATED EQUIPMENT SHALL HAVE INDIRECT WASTE PIPING TERMINATING OVER FLOOR SINK WITH P-TRAP AND A MINIMUM OF 1 INCH AIR GAP. SCALE 7 TYPICAL FLOOR SINK N.T.S. C403.2.9 WSEC PIPING INSULATION ALL PIPING SERVING AS PART OF A HEATING OR COOLING SYSTEM SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH TABLE C403.2.9. TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) OCCUPANCY A, E I-1 , I- 3, 1-4 1-2 Ra F-2, S- 2b, U B, F-1, , 5-1 H-1 H-2 H-3, H-4 Ff•5 S NS S NS S NS S NS S NS S NS 5 INS S NS S NS S NS A, E N.P i ? N 1 2 NP NP 3 4 I 11a. 1-3, 1- — — h. = 1,=' 1 NP = 1 2 NP NP 3 NP � _ 1-2 ? IMP NP ? NP NP NP 3 IMP 2 NP _ Ra — — — — — — i, k I 2c 1 2 NP NP 3 NP 2 I.= F- ,S u.0 — — — — — — — — N N 1 2 NP NF 3 B, F-1, M. 5-1 — — — — — — — — — — N N NP hP ? = H-1 — — — — — — — — — — — — N IMP NP NP NP H-2 — — — — — — — — — — — — — —N NP 1 NP 1 NF H-3, H-4 — — — — — — — — — — — — — — — — 1 d N. P H-S — — — — — — — — — — — — — — — — — — Nr F 5 = Buildings equipped thi aughout. with an aL!tomatic sprinkler sy5terrl installed in accoTdarlce with Section 9033.1.1. NS = Bu11dings not e q u i p p e d throughout with art automatic spNnkIer system installed in accordance with Section 903.3A .1. N = No separation requirement. NP = Not permitted. Tab le 313.3 HANGERS AND SUPPORTS MA+ ERIALS TYPES OF JOINTS HORIZONTAL VERTICAL Lead and Oakum 5 feel, except I feet Vdhere 13asa and each Haar, 10 foot Ie n:glhs are installed 1 2-' n al i a exceed 1 � feed Cast Every ether }pint- url less over 8as5 MCI Each door, Cofnpressran Gasket a feet there supporle-ofb joini1 2 _� nag iv axoeed 15 feel Every other joint. wiless over Basa -and each ROOF. Cast-Ifi}n Hublem Sti;elded Coupllrlg 4 feet then Support each iainll - S. t nai to exceed 15 fuel Copper & Copper {�Ila}�� Soldered Bra=Ed hreadad or 1 ? i Inc-fias and smal! er G feet Ea,ctl flog. not to exceed 1[vets Mech an ical 2 inr hes and I anger 1 i) feet Steel Pipi? for Water o-r ;I inch and smaller. 10 feel. Every other floor. DV V Threaded 13F Welded 1 inch aced larger 12 feei not to exceed 25 feer 11f inch, S feeL 314 Inch and 1 inch. 1-12 inch,.6 few 3/r inch and 1 irrch Steel Pipe lot Gasr Tbreaded {Fr Walued 8 feet 1 t/q inclhi?4 and larger 10 feet 8 fear. l 1/4 inches every flc-cr level Schedule 40 PVC and All si7e3 4 f�eL allay Ease and each floor; provide A B S aV�lV Solvent Cemealed e nor expansion euery 34 tem rrrid�loiy guides: provide fof expansion -every 3D feei t inch and amanef. 3 reef; Base and each ifuor: CPVC Solvent Cemertled 1 '/4 lnchc-5 and larger- 4 feet provide and -story guides Lead Vdlped 43r Burned Conlirtuovs Supp-art !Volta agreed. 4 feel Steal Mec:han!raa Ir• accordance ..Ith slandar�s aucFptable to the AuthOFIty Having dLidsdic!i,r CiAd ExpanaSiart Insert 1 ink and smaller- 32 Inches Base and ear-h Ilakr: PE;; and Compress+.on 1'/4 inches and larger 4 feet provide mitt-slcry guides ill nr~ik PEX-AL-PEX Metal Bnserl and Metal Campression )L/ pC�1 �Gi �iI7C.5 �>t xn[hes 9ase and each Ilu 1 Inch provide mId-slay guidid es 14 indl P E-AL-P E Metal Enserf and Metal Campfession I.4 111ch A I l si&-s 148 ini`hex 93se and each flow provide mId-slay guides 1 Insfi and smaller 32 Inehe4. E-3?e am earn floor provide Pi= T rnserl and Compressio-rr 1114 Inches anO larger 4 feet raid-slmy guides Fusion weld rsackel. j3uH. 1 Inch and smeller- �2 inck;es Base and earn fluor, P�kprapylene IMP) saddle. elaclrafusion}. lhreaded t1 f4 inches and larger a feet provide mid -story guideT, tmetal 1hreadsaniv ar rree#Ianiral Fur S! A D E S I G N S T U D I O 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: WASTE AND VENT PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 03/25/2021 SHEET# RECEIVED Mar 30 2021 ITY OF EDMONDS D LOPMENT SERVICES DEPARTMENT • Auto-Chlor System's proprietary VVaterSaverTM design uses as little as 1.09 gallons/rack • Powerful 1 HP pump delivers high pressure spray and mechanical cleaning action for single pass cleaning performance • Built in water pressure regulator provides consistent water usage and cleaning results • Exclusive fill -through -the -pump feature flushes and cleans the wash pump and spray system with every cycle • External sump and screen provide easy access for cleaning • Regularly scheduled 28-day service ensures sparkling results, minimizes mechanical problems and reduces operating costs • Benefiting from more than 75 years of improvements and dishwashing experience and knowledge A4 watersaverTm Single Rack • In Line • Low Energy Dishmachine ri Energy Efficient • Exceeds Energy Star requirements • Law temperature chemical sanitizing saves energy Total Service. Total Satisfaction. fffiftSYSTEM autochlor.com PERFORMANCE" The new degree of comfort' The PERFORMANCE° High Demand gas water heaters offer larger gallon capacities and exceed ANSI standards for flammable vapor ignition resistance Performance Plus... ■ Recovery Capacity: 72.8 gallons at a ■ Easy to light - no matches required 100' F rise`* ■ Temperature and pressure relief valve Low Emissions included ■ Eco-friendly burner, low NOx design ■ Low lead compliant ■ Meets 40 ng/J NOx requirements ■ Standard replacement parts Maintenance Free ■ Standard 1 " Water connections with Side Water connections for space Burner System heating applications for 75 & ■ Exclusive air/fuel shut-off device 98-gallon models ■ Maintenance free- no filter to clean Warranty ■ disables the heater in the presence of ■ 6-Year limited warranty for tank flammable vapor accumulation and parts, 1-year full in -home labor warranty* 'See written warranty for complete details Combustion Shut -of System Flame Armstar Plate Efficiency I All models tested according to ANSI test procedures, and meet or excead the Thermal efficiency and standby loss requirements of current ASHRAE standard (EPact). Also exceeds energy efficiency codes of all states including California Energy Commission (GEC), Maintenance Free Safety and Constructton I Design certified by GSA: For operation at 160 degraas; meets Al safety and Longer Life r t f ANSI Z21 14 3 ■ Premium grade anode rod provides cansruc s o ., to an automatic storage or instantaneous water heater; as ati Ion wage or PERFORMANCE long-lasting tank protection an automatic circulating tank water heater; and for operation on combustibls floors and in alcove installa- High Demand g High Altitude Compliant 9 P tions. All madelsare North Caro[inaCode comprian'. Certified for 150 PSI 55, 75 and 98-Gallon Capacities maximum working pressure P51 for ASME 75,100 Btu/h ■ All models are certified for (160 models). applications up to 8,500 feet above 80% Thermal Efficient sea level LISTED .II 73 WITH WASH DOOR OPEN T ca, ACM30002 TM A4 watersaver- Single Rack - In Line - Low Energy Dishmachine Specifications Standard 90 second cycle, 38 rack/hr A - Electrical -115 VAC, 6011z, 1 PH - 20A Dedicated Circuit Recommended - Connects to Grounded Wall Outlet or'/z' Conduit depending on local building codes B - Water Consumption 1.09 gal/rack (41.3 GPH) - Water Supply Flow Rate 7.5 GPM Minimum - Water Supply Temp 120'F Minimum - Water Supply Connection 112" NPT female - Backflow protection provided by ASSE 10 Vacuum Breaker C - Drain Connection 2" MPT - 20" above floor C* - Optional Scrap Accumulator - Connection 2" MPT - Centerline 15'/z" above floor D - Wash Cavity Clearance 17" Max Height E - Rack Clearance - 20 %" between tracks - Rack Size 20" x 20" F - Table Height at Machine Entrance 34" Available Options: - Auto -Start - Leg Extensions : 3" - Vapor Removal System (VRX) - 72 second cycle, 47 Racks/hr, 51 GPH - 60 second cycle, 55 Rackslhr, 60 GPH -Tall Hood 27" Max. Height Wash Cavity Optional Supplemental Water Heaters Available An optional integrated water heating system is available for this model dishmachine. The integrated system mounts within the framework of the machine so no additional floor space is required. The integrated heater is ideal for facilities with insufficient water heating capacity, on -demand style water heaters, or remotely located heaters. The heater can operate on 50A 203-240V circuits using either single or three phase power. Contact your local Auto-Chlor System representative for more information. Note: This unit does not produce heat or steam Total Service -Total Satisfaction. SYSTEM autochlor.com The new degree of comfort.' PERFORMANCE High Demand Gas Specifications Fuel Type Description Nominal Rated Gallen Gallon Capacity Capacity Model Number Gas Input in Thous. Btulh ilec©very In OAK 100- F Rise** First Hour Delivery G.P.H. lit. to Vent A Tank Height B Biam. C Ht.to Gas Conn. D Vent Size E Water Conn, fit. to Side Cerder T&P Valve F G Water Conn, Size H Ship Weight (LBS) Uniform Etrisrgy Factor (UEF) Tall 98 93 XG98T065T76U0 75.1 72.8 142 68 64 27-1A 14-318 4 11 57-3116 1 350 0.58 Tall 75 73 1 X075T068T76Up 75.1 72.8 100 64-1l4 60-114 1 28-114 14-3f4 4 11 53-114 1 320 0.61 Tall 55 55 XG55MECB000 50 99 59-118 55-718 23-314 14-1A 4 8 48-314 V4 175 0.62 . ' ... Tall 98 93 XP98T06ST76U0 75.1 72,8 142 68 64 27-V4 14-&8 4 11 57-3116 1 350 0.58 .' T811 75 73 XP75T06ST76U0 75.1 72.8 100 64-1A 60-114 26-1A 14.314 4 11 53-114 1 32D 0.61 . + • ... Tall 55 55 XP55TO6fC45U0 45 97 59-118 55-718 23-314 14-114 4 8 48-314 314 175 0.82 L hiorm Fnergy Fantor and rated gallen rapacity based on Department of Fnargy (I)OF-) requirements. "Recovery Capacity is based upon a 100' F water temperature rise and calculated per ANSI Z21.10.3 standards. Verify with Cross Connection Inspector which fixtures will require Backflow Devices. FLUE (, ANODE ROE)HOTC H WATER I I GOLD CONNECTION WATER CONNECTION I ' F ' -vi Er , 3/4" M.P.T. RELIEF VALVE OPENING 0 0 C� A B G SIDE TAPS 1 /2" D EEN1 I C E` Proven and reliable greaseless bearing will reduce maintenance. Front accessible external air filter for easy cleaning. Hz Nugget Ice ■ Chewable, slow -melting ice. Ideal for use in healthcare, faedserviee and school applications. 3/4" x 5/16" x 3/8" (1.9 x 0.8 x 0,95 cm) Greaseless bearing for reduced maintenance. Stainless steel evaporator for maximum durability a 3 Year parts and labor warranty. a Designed, engineered, assembled in the USA. Ease of Use: a External air filter for easy cleaning. a Unit specific QR code for quick access to service manuals and warranty history. o Slide back door allows easy access to ice in the bin. a Intuitive control panel allows for quick and easy operation. a Ice scoop and power cord included. Compact Design: o Only 24" wide, the ice maker can be placed in the tightest locations. a Optional floor mount kit lowers height to 33.5". High Production: o Produces up to 340 lb (154 kg) per day and stores 80 lb (36 kg), meeting the ice demands for many different applications. Environmentally Friendly: a Meets new US federal energy efficiency requirements. a Meets US Safe Drinking Act law lead requirements. a Non -ozone depleting R-134A refrigerant. 24 Hour Volume Production Air Cooled Water Cooled 70T12VC Air 9TF/32'C 7C'F/21'C Ai, 90°F/32°C 50'F/10'C waver 7D'F21'C 50'F110`C Wit , 70'F/21'C 3401154 266/121 340/154 281/127 Iblkg IbAg Ib/kg lb/kg. V9 Certification EVER Fzeeforei� STAITo RDs CERUMeUS )uu41C hS Warranty - 3 years parts and labor on all components. - 5 years parts on the compressor. - Warranty valid in North, South & Central America for commercial installations. - Contact factory for warranty In other regions. - Residential Applications: 1 year parts and labor Sco ILM, 51 Irran ® a 101 Corporate Woods Parkway, Vernon Hills, IL 60061 a 0 1-800-SCOTSMAN o Fax: 847-913-9844 o www.scotsman-ice.cam o customer.relatiofts@scotsman-ice.com a WATERINLEr ACCESB PGA COP n,><m [s 3cm CLR2CE �,poe�a��ee UNIT DRAIN 3WFPS i°eb-a o°d'a'�n°a��• WATERINLET We FLARE CONDENSEP WATER MLET3fB ISNPT CONDENSER wATER Dr lry CONNE{TION 11`A-r4NPT t 13.ficmS i166cm ] [1 19cm ] [ 1 in a.Tln 5.4In POWER CORD r 6.4in WATER REGULAMIR AOAISTMENTACCESS [2i.5cm 1 9 ��n Specifications S i � Water Usage Storage Energy Consumption Gallons/100 lb (liters/45.4 kg) Model Condenser Capacity Basic Electrical Total Load Min. Circuit kWh1100 lb (45.4 kg) Potable Condenser Number Unit Ib/kg VOItslHz/Phase Amps Ampacity 90'F(32`Q170-F(21°C) 90'F(32'C)170`F(21°C) UN324A-7 Air 80/36 T 15/60/1 9.5 Cord 5.47 12.0l45.5 - UN324W-1 Water 80136 115/60/1 9.0 Cord 4.55 12.0/45.5 68/308.7 11:1 11�= All Models Dimensions (W x D x H): Unit' 24" x 28.5" x 39" (61.0 x 72.4 x 99.1 cm) Includes 6" (15.24 cm) adjustable legs Shipping Carton: 28.75" x 38.65" x 39" (73.0 x 98.2 x 99.1 cm) Shipping Weight: 2101b / 95kg BTUs per hour: 2.000 Refrigerant: R-134A Accessories Model Number Description KLPSS Kit, Leg 6", Stainless Steel KBC1 Kit, Casters KUFM24 Floor mount kit, towers height to 33.5" Operating Requirements Minimum Maximum Air Temperatures 50-F (l0°C) 100°F (38°C) Water Temperatures 40°F (4.4'C) 100°F (38°C) Water Pressures 20 PSIG (1.4 bar) 80 PS€G {5.5 bar) Electrical Voltage -5% f101% specifications and design are subject to change without notice. Scotsman recomlrends all ice machines have water filtration. See Scotsman water filter speciiicatian sheet for details, a 101 Corporate Woods Parkway, Vernon Hills, IL 60061 a Sco �� � 0 1-800-SCOTSMAN o Fax: 847-913-9844 o wwwscotsman-ice.com a customerrelations9scotsman-ice.com o 0 2017 5cot5man Ice Systems 515.55-NUG-UN324 10-17 FAIT D E S I G N S T U D I O 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: SPEC SHEET DISH WASHER, ICE MAKER, GREASE INTERCEPTOR, HOT WATER TANK REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 03/25/2021 SHEET# RECEIVED Mar 30 2021 ITY OF EDMONDS ELOPMENT SERVICES DEPARTMENT SYSTEM NO.C-AJ-1081 F-RATING 2-AND 3-HR/T-RATING 0-HR OrAl 1? 00 EXPANSION BOLT TO EXISTING CEILING STRUCTURAL 3/8" DIA. METALLICS JDEA38 ZINC CHROMATE ZINC ALLOY DOUBLE EXPANSION ANCHOR, LENGTH 1.5" ,DRILL SIZE 3/4" RESTAURANT FLOOR LEVEL a a as � � aaa aas as a a a a a a 4" INLET 3/8" THREADED STEEL ROD TITE TO GREASE INTERCEPTOR BRACKET WITH HEAVY DUTY LOCK NUTS. 12 GA. "U" CHANNEL 00 sine view GREASE INTERCEPTOR MOUNTING DETAIL OUTLET 3/8" THREADED STEEL ROD EA SIDE 3/8" THREADED STEEL ROD PERPENDICULAR TO PLANE SPECIFICATION AND SUBMITTAL B235 5U GPM Grease Interceptor for Indoor Use 23" (58 cm) 8-3/41' (22 cm) 13 - 3/4" (35 cm) This unit is certified to ASME A112.14.3 (Type C) and Satisfies Miami DERM 99% efficiency requirements GSA B481.1 at two different flow rates and includes the internal flow when at least 2 units are installed in series controls for both. External flow control with vent not required. SUBMITTAL Standard options Location: indoor -FO: fixed outlet diffuser Installation: above/below grade [] FCRI (xl): > 2-1/8" - 12" field cut riser Flow Rates f Grease Capacities: ❑ FCRI (x2): > 12" - 24" field cut risers 35 GPM (2.2 L/s) / 130.5 lbs. (59.2 kg) CC1: membrane clamping collar kit (requires FCRI riser) 50 GPM (3.2 L/s) / 127.6 lbs. (57.9 kg) ❑ PPI: pumpout port kit Solids Capacity:1.8 gal. (6.8 L) Liquid Capacity: 20 gal. (75.7 L) SGK2: support gusset kit Weight: 49 lbs. (22.2 kg) 0 PLAIN-EA-24: 2" (50 mm) plain end fitting Connections: 3" (75 mm) and 4" (100 mm) plain end ❑ FPT-EA-34: 4" x 3" (100 mm x 75 mm) FPT fitting Cover bolted gas/water tight polypropylene with 1,000 lb. load rating FPT-EA-23: 3° x 2" (75 mm x 50 mm) FPT fitting when unit is buried with FCRI riser Approval Signature: Date: Company: Specifying Engineer. Engineering Firm: END VIEW CONTRACTOR MUST REINSTALL BATT INSULATION PER BUILDING REQUIREMENT HYDROMECHANICAL GREASE INTERCEPTOR 50 GPM PRODUCT CODE: GB-2 BY SCHIER (FIELD VERIFY THE LOCATION BY CONTRACTOR) 3/8" THREADED STEEL ROD TITE TO GREASE INTERCEPTOR BRACKET WITH HEAVY DUTY LOCK NUTS. THROUGH PENETRATION. USG SHEETROCK® BRAND FIRECODE® COMPOUND MIN.1" [251 THICKNESS. FLOOR ASSEMBLY. D E S I G N S T U D I O 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM a a ° err a ° a �rr ° Q a ° Q rrr a a a a ° ° a a PROJECT TITLE: ° SCALE: 111 = 11.011 FLOOR PENETRATION DETAIL High Water Table Installations Interceptors and risers are not designed to withstand water table height imax water table height n for direct burial excess of the top of the unit when buried (see figure). If it is possible for this to occur, install the interceptor and risers in _ a water -tight concrete vault or backfil! Interceptor with concrete or fIowa ble fill (wet concrete and flowable backfill should be poured in stages to avoid crushing the interceptor). At risk areas include but are not limited to tidal surge areas, floodplains and areas that receive storm water. Great Basin"' models that are direct buried in high water table scenarios must be installed with an anchor kit. Models GB-50, GB-75, and GB-250 use model AK1 anchor kit. Model GB-500 uses model AK2 anchor kit for use with deadmen anchors. Models 013-1000, GGI-750 and GGI-1500 use model AK3 anchor kit for use with deadmen anchors. Flush -to -Grade Burials Flush -to -Grade buried installations (without a riser) are not recommended for heavy foot traffic areas without the use of an internal gusset support kit SGK2 (for GB2) or SGK3 (for G133). Fully Support Base of Unit Install unit on solid, level surface in contact with the entire footprint of unit base; for suspended installations design trapeze to support the wet weight of the unit. Do not partially support unit or suspend unit using metal U-channel to create a trapeze. Support Inlet and Outlet Piping For above grade installations ensure heavy inlet and outlet piping (such as cast iron or long runs) is properly supported or suspended during the entire installation process to prevent connection failure or damage to bulkhead fittings. concrete floor ��� Interceptorl� suspended installation pipe supports Interceptor SPECIFICATIONS Notes 1. 4" FPT inlet/outlet with 3" and 4" plain end fittings. 2. Unit weight - 49 lbs. (wet weight 216 lbs.) 3. Capacities - Liquid: 20 gal. @35 GPM- Grease: lbs. �17.3 g 17.8 gal. @}50 GPM- Grease: 127 lbs. al. Solids: 1.8 gal. 4. Built-in flaw control. 5. For gravity drainage applications only. S. Do not use for pressure applications. 7. Cover placement allows full access to tank for proper maintenance. 8. Vent not required unless per local code_ 9. Engineered inlet and outlet diffusers are removable to inspect/clean piping. 10. Integral air relief f anti -siphon. Engineer Specification Guide Schier Great Basin TM grease interceptor model #GB2 shall be lifetime guaranteed and made in USA of seamless, rotationally -molded polyethylene. Interceptor shad be furnished for above or below grade installation. Interceptor shall be certified to ASME A112.14.3 (type C) and CSA B481.1, with field cut riser system, built-in flow control and three outlet options. Interceptor flow rate shall be 35 or 50 GPM. Interceptor grease capacity shall be 130 lbs. @ 35 GPM or 127 lbs. @ 50 GPM. Cover shall provide water/gas-tight seal and have minimum 450 lbs. load capacity. Certified Performance Great Basin'" hydromechanical grease interceptors are third party performance -tested and listed by IAPMO to ASME #A112.14.3 and CSA B481.1 grease interceptor standards and greatly exceed requirements for grease separation and storage. They are compliant to the Uniform Plumbing Code, the National Standard Plumbing Code, the National Plumbing Code of Canada, and the International Plumbing Code_ METALLIC SLEEVE WHERE SPECIFIED. MINERAL WOOL. METALLIC SLEEVE WHERE SPECIFIED. THROUGH PENETRATION. USG SHEETROCK® BRAND FIRECODE® COMPOUND MIN. THICKNESS 1 [251. SCALE : N.T.S. TOP VI EW 35" outlet "A" (optional} OPq�q'q�q�q�o� Pq�q�q�q�q�gPq o O °�°17 aa°1 °e a°b°O°a°D� q�q�% % A O°4°qA0° aR°O°q°q A 1 q�O°qOq°qaq J ga4a p Q��gQaa° 23" - .. _ Inlet %z' 4°a p d°�°� Outlet "B" ° ° ° ° ° ° (Standard) % % I Outlet foot % % must face this ° ° v ° o ° a ° o direction in all °oo°aa°o°ago a°°qo°a°oqo° configurations gageqoaaqeaoqe eOegeOodn°Qaati Outlet "C" (optional) 7/16" SECTION A -A q of 4' FPT inlet &outlet � o 21-1/2" Cover 5" 13-3/4" I -- 8_3/4. OUTLET END VIEW 23 Engineered inlet and outlet diffuser See Note #10 _T 17 6-3/4" invert f Static water line Rated Grease Capacites for Units Piped in Series No. of Units Removal Efficiency in Series 97.8% 99%* 2 2741bs, 180lbs. NOTE: Flow rate for 2 GB2 units piped in series is 35 GPM only * Satisfies Miami GERM 99% efficiency requirements HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: GREASEINTERCEPTOR SPEC SHEET AND DETAILS REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 03/25/2021 SHEET# RECEIVED Mar 30 2021 ITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Pagelof4 Page 3of4 Page 4 of 4 'ju -V 22'-5" 12-10" 7'-9" 9'-11" CONN ... IONS 19"A.F.F. THIS WALL TO THIS 3 COMP. SINK TO BE THIS BE REMOVED REMOVED o CONNECTIONS TO BE REMOVED a EXISTING ti 3 COMP SINK w ti m THIS o CONNECTIONS TO BE REMOVED THIS WALL TO CONNECTIONS LASTING 16"A.F.F. GREASE BE REMOVED INTERCEPTOR HIS GREASE INTERCEPTOR TO BE _ REMOVED c' THIS DOOR TO THIS WALL TO THIS WALL TO BE REMOVED �BE REMOVED THIS DOOF TO BE REMOVED BE REMO ED CONNECTIONS THIS WALL TO THIS CONNECTION-/16"A.F.F. BE REMOVED (E)ELECTRICAL �\ TO BE REMOVED THIS WALL TO PANEL TO BE BE REMOVED RELOCATED THIS RESTROOM THIS WALL TO TO BE !,REMOVED BE REMOVED 0 W 0 33'-8" 20' EXISTING AND DEMOLITION PLAN �7, SCALE: 1/4" = V-0" 1*03 1, 31'-11" I, 7'-6" 1, 1, 13'-5" INSTALL A SIGN THAT READS THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." INSTALL ACCESSIBLE EXIT SIGN. W Z a H Z W Z Ca G INSTALL MAXIMUM OCCUPANCY LOAD SIGN "MAXIMUM OCCUPANCY LOAD 32 PERSONS" NEW FLOOR PLAN SCALE: 1/4" = V-0" TOTAL: 28 SEATS OCCUPANCY LOAD : FLOOR AREA : 1,049 SQ.FT. ROOM NAME FLOOR AREA OCCUPANT LOAD FACTOR OCCUPANT LOAD 1. DINING AREA 325 S.F. 15 (NET) (DINING) 22 2. COUNTER HEIGHT-1 21 S.F. 7 (NET) (DINING) 3 2. COUNTER HEIGHT-2 21 S.F. 7 (NET) (DINING) 3 3. KITCHEN AREA 356 S.F. 200 GROSS (KITCHEN) 2 4. SERVICE AREA 62 S.F. 100 GROSS (SERVICE) 1 5. RECEPTION AREA 30 S.F. 100 GROSS (SERVICE) 1 6. MEN'S RESTROOM 47 S.F. 100 GROSS (RESTROOM) 1 7. WOMEN'S RESTROOM 47 S.F. 100 GROSS (RESTROOM) 1 8. BUSINESS 66 S.F. 100 GROSS (BUSINESS) 1 TOTAL OCCUPANT LOAD: 35 OCCUPANTS FOR REFERENCE ONLY :1 NOTES FOR HEALTH DEPARTMENT: NOTE: ALL GLAZED DOORS TO HAVE .60 U-VALUES AND .45 SHGC VALUES NO CHANGE ON EXTERIOR WINDOWS SHELVING: REFRIGERATORS: STAINLESS STEEL STEEL SHELVES; DRY STORAGE: LAMINATE/ WOOD; DRYING RACK: STAINLESS STEEL; CHEMICALS SHELVING: WIRED RACK ALL PAINT IN KITCHEN, PREP. AREA, AND SCULLERY AREA IS SEMI -GLOSS. THERE'RE NO UNNECESSARILY EXPOSED UTILITIES. BE ADVISED THAT THE NEW WASHINGTON STATE FOOD CODE REQUIRED COMMERCIAL REFRIGERATION TO HOLD FOOD AT 41 DEGREES FAHRENHEIT OR BELOW (DOWN FROM 45 DEGREES) FULL HEIGHT STAINLESS STEEL PANEL WALL BEHIND COOKING LINE, TYP. 4'4' HEIGHT FRP PANELS AROUND KITCHEN WALL, TYP. EXHAUST HOOD SYSTEM & FIRE SUPPRESSION SYSTEM BY OTHERS 5% OF THE SEATING SHALL BE ACCESSIBLE AND DISPERSED THROUGHOUT THE DINING AREA. SHOW FOR ACCESSIBLE SEATING SPACES ASSEMBLY OCCUPANCY WITHIN THE BUILDING SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE T-BAR CEILING, WASHABLE (WATERPROOF - USDA. FDA. HEALTH DEPARTMENT, CFIA APPROVED) MAXIMUM OCCUPANCY NOT TO EXCEED PERSONS SPECIFIED MAX. ON ALL SIGNS SEE A1, ON FLOOR PLAN ASSEMBLY OCCUPANCY WITHIN THE BUILDING SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE B OCCUPANCY LOAD SIGN j.8e 8 - NOTE: IBC 1013.4, "RAISED CHARACTER AND BRAILLE EXIT SIGNS" "A SIGN STATING EXIT IN VISUAL CHARACTERS, RAISED CHARACTERS, AND BRAILLE, AND COMPLYING WITH ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY OR RAMP, AN EXIT PASSAGEWAY, AND THE EXIT DISCHARGE. A RAISED CHARACTER AND BRAILLE EXIT SIGNS I 14 I ,GREASE (INTERCEPTER BEL ,AT LOWER FLOOR ,(FIELD VERIFY) I I I I I 0'-10" ADA COUNTER HEIGHT 3 THE TOPS OF COUNTER WORK SURFACES SHALL INCHES MAXIMUM FROM FLOOR OR GROUND. EQUIPMENT SCHEDULE CD z 'u SUPPLIER z DESCRIPTION MANUFACTURER MODEL NUMBER DIMENSIONS (L.XD.XH.) ELECTRICAL PLUMBING GAS NOTES z zo BTU U 75000 Lu Z w z o z X w F ¢ v' Q = o Y z zo U = 1/2" o o v 1/2" Q 1 1/2" 1 X 1 HOT WATER TANK RHEEM 75 GALLON #XG75T06ST76UO 2 X 1 MOP SINK ADVANCE TABCO #9-OP-20 (21 X25 X10)1 1/2 1/2 1 1/2 DIRECT 3 X 5 REACH -IN COOLER AVANTCO #178A35RHC (39.5"X29.5"X82.5") 4.3 1/4 115 4 X 1 GREASE INTERCEPTOR SCHIER #GB2 REGENCY #60OS3182418XLFT 5 X 1 3 COMP. SINK 1/2" 1/2" 1 1/2" DIRECT CONNECT 6 X 1 DISH WASHER AUTO-CHLOR A4WATERSAVER CDTL-24-16/4 1/2" 1 1/2" INDIRECT 7 X 1 CLEAN TABLE 8 X 1 1 COMP. SINK (VEG.) REGENCY #60OS1181818XLFT 1/2" 1/2" 31/2" INDIRECT 9 X 1 1 COMP. SINK (MEAT) REGENCY #600S1181818XRT 1/2" 1/2" 31/2" DIRECT 10 X 2 HAND SINK EMPURA E-HSI5SPWF(15"WX15.75"DX13"H) 1/2" 1/2" 1 1/2" INDIRECT 11 X 1 WORK TABLE REGENCY #60OT2424S (24"X24") 12 X 1 RICE COOKER TOWN FOOD SERVICE #RM-55N-R 34,600 13 X 3 DRY STORAGE ULINE WIRE SHELVING H-2936-54 36"X12"X54" 14 X 1 WORK TABLE REGENCY #60OT246OG 15 X 1 MICROWAVE SOLWAVE #180MWASS022 (13"x9 7/8") 2,200 240 16 X 1 SANDWICH COOLER AVANTCO #178APT48MHC (46 3/4"x35"X45 7/8") AMERICAN RANGE AF-45 7.8 1/4 115 120,000 17 X 1 DEEP FRYER WOK 18 X 1 #351 CPGWOKNG (18"WX20.5"DX30.7"H) 95,000 19 X 2 STOCK POT AMERICAN RANGE ARSP-18 (18"X21 "X24") 26.37 90,000 20 X 1 NOODLE STEAMER L&T RESTAURANT EQUIPMENT #PENC-M18 21 X 1 HOOD BY OTHER 22 X 1 DELIVERY STATION WORK TABLE REGENCY #60OT1860G 23 X 1 P.O.S BY OTHER 24 X 1 HAND SINK EAGLE GROUP #WS14-15 38.7 1 208 1/2" 1/2" 1 1/2" INDIRECT 25 X 1 TEA HOTPOT TBS-2121XTS INDIRECT 26 X 1 UNDER COOLER BEVERAGE AIR #BB36HC-1-G-B 1/4 1742 27 X 1 ICE MAKER EMPLOYEE LOCKERS SCOTSMAN #UN324A-1 ULINE H-6745GR 6 LOCKERSI2" X 18" X 72" 9.5 115 1/2" 1 1/2" INDIRECT 28 X 1 0 416342 B ADA COUNTER DETAIL PLUMBING NOTE: PLEASE NOTE THAT THE FOLLOWING FIXTURES MUST DISCHARGE INTO THE GREASE INTERCEPTOR - KITCHEN FLOOR DRAINS - 3 COMPARTMENT SINK - MOP SINK - DUMP SINK - MEAT SINK SCALE: N.T.S. ROOM FINISH SCHEDULE # ROOM WALL CEILING FLOOR COVED BASE COUNTER 1 MAIN DINNING AREA GYPSUM WALLBOARD/PAINT T-BAR CEILING WOOD LAMINATE FLOOR 4" TILE BASE STAINLESS WATER RESISTANT GWB BEHIND 2 PREP AREA/KITCHEN PLUMBING FIXTURES 8' FRP AROUND T-BAR CEILING NON -SLIP CERAMIC TILE 6" TILE BASE STAINLESS BAR AREA WALLS TYP. GYPSUM WALLBOARD/PAINT T-BAR CEILING WOOD LAMINATE FLOOR 4" TILE BASE STAINLESS 3 4 RESTROOM WALL TILE DAY WALL CEILING CERAMIC TILE 4" RUBBER BASE GRANITE DOOR SCHEDULE DR# WIDT HT. THK. DOOR MAT/FIN. DTOPE REMARKS HARDWARE GROUP KEY NOTES 001 3'-0" 8'-0" 1-3/4 11 ALUM. FRAME/W GLAZING A* (EXISTING) EXTERIOR DOOR; MAIN ENTRANCE 1, 3, 5, 9, 11, 12, 13 002 3'4' 6 4' 1-3/4" KITCHEN STAINLESS STEEL B (NEW) INTERIOR DOOR POSTED KITCHEN 9, 10, 12, 14 003 3'4" 3-0" 6'-8" 64' 1-3/4 11 SOLID CORE WOOD SOLID CORE WOOD C (NEW) INTERIOR DOOR POSTED MEN'S RESTROOM (NEW) INTERIOR DOOR POSTED WOMEN'S RESTROOM 6, 10, 14 004 1-3/4 C 6, 10, 14 11 * THIS DOOR SHALL HAVE A SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." 1) ALL DOORS REQUIRED FOR ADA COMPLIANCE TO BE FITTED W/ APPROVED LEVER -TYPE HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. 2) MAX.1/2" THRESHOLD A.F.F. HARDWARE GROUP KEY NOTES 1. PANIC HARDWARE 5. COMMERCIAL UNLOCKED INDICATOR 10. KICK PLATE 2. PUSH BAR 6. PRIVACY, LEVER OPERATED HARDWARE 11. WEATHER STRIP 3. EXTERIOR PULL HANDLE 7. KEYED LOCKSET (SECURITY) 12. THRESHOLD 4. INTERIOR PULL HANDLE AND PUSH PLATE 8. RIM CYLINDER LOCK 13. TOP & BOTTOM PIVOT 9. CLOSER 14. HINGE DOOR NOTES 1. FINISH ALL WOOD DOOR/ WITH CLEAR COAT SUITABLE FOR EXTERIOR USE 2. DOORS WITHIN THE PATH OF TRAVEL FOR HANDICAPPED TO BE OPENABLE WITH A SINGLE EFFORT BY LEVER, PANIC BAR OR PUSH/PULL HARDWARE. 3. EXIT DOORS TO BE OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 4. DOOR CLOSERS TO BE ADJUSTED TO PROVIDE FOR A MAXIMUM EFFORT TO OPERATE OF 15 LBF. 5. THRESHOLDS SHALL NOT EXCEED 1/2" IN HEIGHT 6. BOTH SIDES OF DOORS SHALL BE FINISHED THE SAME, UNLESS OTHERWISE NOTED 7. ALL LEGAL EXITS SHALL BE PROVIDED WITH SELF-ILLUM EXIT SIGNS HAVING 6" LETTERS WITH 3/4" STROKES IN CONTRASTING COLORS. 8. HARDWARE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER HARDWARE INCLUDING BACKSETS, STRIKES, ETC. 9. THE OPENING FORCE FOR ACCESSIBLE EXTERIOR DOORS SHALL NOT EXCEED 81/2 POUNDS FORCE. @FAI'T D E S I G N S T U D I O 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: EXISTING & DEMOLITION PLAN FLOOR PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 03/25/2021 SHEET# RECEIVED Mar 30 2021 l TY OF EDMONDS LOPMENT SERVICES DEPARTMENT