REVIEWED BLD-BLD2022-0099+Structural_Analysis_or_Calculations+1.25.2022_8.53.00_PM+2641537E ESGDESIGN Eli Grassley, P.E. RECEIVED _ """"'REVIEWED"""" BY Jan 27 2022 BLD2022-0099 CITY OF EDMONDS CITY OF EDMONDS BUILDING DEPARTMENT DEVELOPMENTSERVICES """"""""""""""""""""""""` DEPARTMENT 5TRUCTURAL CALCULATION5. FOR ANDREWS REMODEL Edmonds, kYA 1-19--2022 PREPARED BY: JANUAPY /9, 2022 % '810 ENGINEERED • STRUCTURES • GLOBAL • DESIGN ESG Design, PLLC - 12540 202nd PL SE, Issaquah, WA 98027 1 engineer@esg-design.com 1 206-660-2044 NC�IN 1� 5Tl�UGTU S 610'�5AL Dff516N, F71 ESGDESIGN Protect: Andrews Remodel Description: Remodel with structural alterations and changes to existing exterior shearwall Location: Edmonds, WA Code: IRC 2018 STRUCTURAL LOADING SUMMARY Vertical Loads: Attic LL = 10 PSF Roof DL = 12 PSF Roof SL = 25 PSF Lateral Loads: Existing assumed shearwall lateral strength = 200 PLF Size new retrofit shear wall to receive capacity of lost exterior wall length. See elevation markup. ESGDESIGN (N) HEADER PER FRAMING PLAN (N) WINDOW, MATCH "I3E" 51ZE--\ VERIFY (E) OR PROVIDE) A 3 (N) EXTERIOR SHEATHING PER 5W SCHEDULE, PROVIDE (N) HOLD-DOWNS PER HD SCHEDULE (N) HOLD-DOWN5�j u (N) 5HEARWALL SKYLIGHT (E) DOOR "23E" TO BE SHIFTED LEFT (E) 5HEARWALL PORTIONS TO BE REMOVED A55UMED EXISTING 5HEARWALL CAPACITY = 200 PLF REMOVED 5HEARWALL PORTIONS TOTAL LENGTH = 9'-8" TOTAL REMOVED 5HEARWALL 5TRENGTH = 200 * 9.GG = 1932# REQUIRED NEW 5HEARWALL STRENGTH = 1932# / 4.33' = 44G PLF VERIFY EXI5TING OR PROVIDE NEW 5HEARWALL 5HEATHING AND NAILING: 7/ 1 G" - SHEATHING, 8d @4"oc NAILING, CAPACITY 513 PLF Eli Grassley, P.E. ENGINEERED STRUCTURES GLOBAL DESIGN Andrews remodel ESG DESIGN, PLLC JOB Andrews Remodel Consulting Engineers DATE Jan 19, 22 ESG 12540 202nd Place SE SUBJECT Shear Wall Analysis Summary Issaquah Washington 98027 SHEET NO. 1 This sheet performs calculations for Perforated Shearwalls per IBC 2015 - ASD Shear Wall Data L Results Callouts Shear Line I V LWALL LFULL-HT HWALL HOPEN DL Co v R R_total 2bs/h* ARF* SW HD Notes (Ibs) (ft) (ft) (ft) I (ft) (plf) (plf) (Ibs) (Ibs) Adjustment Flag Adjustment I TYPE (Perforated) (Segmented) MAIN LEVEL (auto) (manual) EAST/ WEST(on plan) NEW SW 1 1932 1 4.33 1 4.33 7.80 1 0.00 180 1.00 446 3246 1.00 1.00 A HD1 HOLDOWN SHEDULE Taq Item Capacity Post AB HD1 HDU4 3285# (2)2x 5/8" DIAM 10" EMBED *2bs/h is applied to the v results in this spreadsheet while the Aspect Ratio Factor (ARF) is accounted for SHEAR WALL SCHEDULE manually by reducing the capacity of the choosen SW Tag Sheathing Nail Size a AB Capacity (Wind) A 7/16" One Side 8d @ 4"o.c. 513# a" O R T CM MEMBER REPORT PASSED Main Floor, (N) 8' Kitchen Door HDR 1 piece(s) 3 1/2" x 7 1/2" 24F-V4 DF Glulam Overall Length: 8' 6" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2464 @ 1 1/2" 6825 (3.00") Passed (36%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1957 @ 10 1/2" 5333 Passed (37%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 4934 @ 4' 3" 7547 Passed (65%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.182 @ 4' 3" 0.275 Passed (L/543) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.273 @ 4' 3" 0.412 Passed (L/363) 1 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 8' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports IV Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - HF 3.00" 3.00" 1.50" 818 1647 2465 None 2 - Trimmer - HF 3.00" 3.00" 1.50" 818 1647 2465 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 6" o/c Bottom Edge (Lu) 8' 6" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 8' 6" N/A 6.4 1 - Uniform (PSF) 0 to 8' 6" 15' 6" 12.0 25.0 Roof Load System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Mark Trembach ESGD (701) 660-9422 mark.esgd@outlook.com 1/14/2022 11:56:51 AM UTC ForteWEB 0.2, Engine: V8.2.O.17, Data: V8.1.0.16 Weyerhaeuser File Name: Andrews Remodel Page 1 / 1 a" O R T CM MEMBER REPORT PASSED Main Floor, (N) 8' Kitchen Door HDR Post 2 piece(s) 2 x 4 HF No.2 Drawing is Conceptual Wall Height: 6' 8" Member Height: 6' 3 1/2" Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 25 50 Passed (50%) -- -- Compression (Ibs) 2465 3507 Passed (70%) 1.15 1.0 D + 1.0 S Plate Bearing (Ibs) 2465 4463 Passed (55%) -- 1.0 D + 1.0 S Lateral Reaction (Ibs) 49 1.60 1.0 D + 0.6 W Lateral Shear (Ibs) 45 1680 Passed (3%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 77 @ mid -span 1029 Passed (8%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.05 @ mid -span 0.63 Passed (L/1446) -- 1.0 D + 0.45 W + 0.75 L + 0.75 S Bending/Compression 0.73 1 Passed (73%) 1.15 1.0 D + 1.0 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for this design is 16.67% of applicable member side dimension. • Applicable calculations are based on NDS. • The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to the U.S. Wall Guide for multiple -member connection requirements. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Max Unbraced Length Comments 6' 3 1/2" Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d x 2.5" Box (Toe) 1 N/A Base Nails 8d x 2.5" Box (Toe) 1 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : Aso • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Snow (1.15) Comments 1 - Point (lb) N/A 818 1647 HDR Load Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 1' 26.1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Mark Trembach ESGD (701) 660-9422 mark.esgd@outlook.com 1/14/2022 11:58:18 AM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Andrews Remodel Page 1 / 1 a" O R T CM MEMBER REPORT PASSED Main Floor, (N) T-10" Kitchen Window HDR 1 piece(s) 4 x 8 HF No.2 Overall Length: ; 5' 10" Ivl All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. ❑2 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1836 @ 1 1/2" 4253 (3.00") Passed (43%) 1.0 D + 1.0 S (All Spans) Shear(lbs) 1341 @ 10 1/4" 2918 Passed (46%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 2683 @ 3' 2" 3247 Passed (83%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl.(in) 0.083 @ 3' 2" 0.203 Passed (L/883) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.124 @ 3' 2" 1 0.304 Passed (L/590) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Trimmer - HF 3.00" 3.00" 1.50" 609 1227 1836 None 2 - Trimmer - HF 3.00" 3.00" 1 150" 609 1227 1836 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 64" o/c Bottom Edge (Lu) 64" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 4" N/A 6.4 1 - Uniform (PSF) 0 to 6' 4" 15' 6" 12.0 25.0 Roof Load System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : Aso Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Mark Trembach ESGD (701) 660-9422 mark.esgd@outlook.com 1/19/2022 8:34:59 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Andrews Remodel Page 1 / 1 a" O R T CM MEMBER REPORT PASSED Main Floor, (N) V-10" Kitchen Window HDR Post 2 piece(s) 2 x 4 HF No.2 Drawing is Conceptual Wall Height: 6' 8" Member Height: 6' 3 1/2" Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 25 50 Passed (50%) -- -- Compression (Ibs) 1832 3507 Passed (52%) 1.15 1.0 D + 1.0 S Plate Bearing (Ibs) 1832 4463 Passed (41%) -- 1.0 D + 1.0 S Lateral Reaction (Ibs) 49 1.60 1.0 D + 0.6 W Lateral Shear (lbs) 45 1680 Passed (3%) 1.60 1.0 D + 0.6 W Lateral Moment (ft-Ibs) 77 @ mid -span 1029 Passed (8%) 1.60 1.0 D + 0.6 W Total Deflection (in) 0.04 @ mid -span 0.63 Passed (L/1711) -- 1.0 D + 0.45 W + 0.75 L + 0.75 S Bending/Compression 0.43 1 Passed (43%) 1.15 1.0 D + 1.0 S • Lateral deflection criteria: Wind (L/120) • Input axial load eccentricity for this design is 16.67% of applicable member side dimension. • Applicable calculations are based on NDS. • The column stability factor (Kf = 0.6) applied to this design assumes nailed built-up columns per NDS section 15.3.3. For Weyerhaeuser ELP products refer to the U.S. Wall Guide for multiple -member connection requirements. Supports Type Material Top Dbl 2X Spruce -Pine -Fir Base 2X Spruce -Pine -Fir Max Unbraced Length Comments 6' 3 1/2" Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d x 2.5" Box (Toe) 1 N/A Base Nails 8d x 2.5" Box (Toe) 1 N/A System : Wall Member Type : Column Building Code : IBC 2015 Design Methodology : Aso • Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Vertical Load Tributary Width Dead (0.90) Snow (1.15) Comments 1 - Point (lb) N/A 605 1227 HDR Load Lateral Load Location Tributary Width Wind (1.60) Comments 1 - Uniform (PSF) Full Length 1' 26.1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (33% Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Mark Trembach ESGD (701) 660-9422 mark.esgd@outlook.com 1/14/2022 12:10:39 PM UTC AForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Andrews Remodel Page 1 / 1 a" O R T CM MEMBER REPORT PASSED Roof, Skylight cross-bearms 2 piece(s) 2 x 4 HF No.2 Overall Length: A' 1' 0 0 i 3' 10" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. I 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 413 @ 3' 11 1/2" 1823 (1.50") Passed (23%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 412 @ 3' 8" 1208 Passed (34%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-Ibs) 735 @ 2' 2" 748 Passed (98%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl.(in) 0.076 @ 2' 11/16" 0.192 Passed (L/606) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl.(in) 0.112 @ 2' 11/16" 1 0.256 1 Passed (L/412) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Hanger on 3 1/2" SPF beam 1.50" Hanger' 1.50" 117 93 234 444 See note' 2 - Hanger on 3 1/2" SPF beam 1.50" Hanger' 1 1.50" 133 107 266 506 See note' • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 3' 10" o/c Bottom Edge (Lu) 3' 10" o/c -Maximum allowable bracing intervals based on applied load. System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : Aso Member Pitch : 0/12 Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1- Face Mount Hanger LUS24-2 2.00" N/A 4-10dx1.5 2-10d 2 - Face Mount Hanger LUS24-2 2.00" N/A 4-10dx1.5 2-10d • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 0 - Self Weight (PLF) 1 1/2" to 3' 11 1/2" N/A 2.7 1 - Point (lb) 2' 2" (Front) N/A 240 200 500 Truss load Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Mark Trembach ESGD (701) 660-9422 mark.esgd@outlook.com 1/19/2022 10:37:14 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Andrews Remodel Page 1 / 1 LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers (cont.) Model No. Min. Heel Height Ga Dimensions (in.) Fasteners W H g Carrying Member Carried Member Single 2x Sizes LUS24 2% 18 19/a 31/a 13/4 (4) 0.148 x 3 (2) 0.148 x 3 LUS26 41/4 18 19/a 43/4 13/4 (4) 0.148 x 3 (4) 0.148 x 3 MUS26 411tia 18 19/a 5'/1a 2 (6) 0.148 x 3 (6) 0.148 x 3 HUS26 41/1a 16 15/a 53/a 3 (14) 0.162 x 31/2 (6) 0.162 x 31/2 HGUS26 41e 12 15/a 5% 5 (20) 0.162 x 31/2 (8) 0.162 x 31/2 LUS28 43/a 18 19/a 6% 13/4 (6) 0.148 x 3 (4) 0.148 x 3 MUS28 69/1a 18 19/a 613/6 2 (8) 0.148 x 3 (8) 0.148 x 3 HUS28 61/2 16 1 % 7 3 (22) 0.162 x 31/2 (8) 0.162 x 31/2 HGUS28 69/a 12 1 % 71/a 5 (36) 0.162 x 31/2 (12) 0.162 x 31/2 LUS210 41/4 18 19/a 713/a 13/4 (8) 0.148 x 3 (4) 0.148 x 3 HUS210 83/a 16 1 % 9 3 (30) 0.162 x 31/2 (10) 0.162 x 31/2 HGUS210 89/a 12 15/a 91/a 5 (46) 0.162 x 31/2 (16) 0.162 x 31/2 1. See table below for allowable loads. -These products are available with additional corrosion protection. For more information, see p. 14. ® For stainless -steel fasteners, see p. 21. Many of these products are approved for installation ®1 with Strong -Drive® SD Connector screws. See pp. 348-352 for more information. APPLIED LOAD ON (E) LONGER TPU55 PORTION END = 940# PROVIDED LOAD BEARING BY TWO "LU524" HANGER5 = 2 . 5G5# = 1 130# Model DF Allowable Loads SIP Allowable Loads SPF/HF Allow bill e Loads Code No. Uplift (160) Floor (100) Snow (115) Roof (125) Wind (160) Uplift (160) Floor (100) Snow (115) Roof (125) Wind (160) Uplift (160) Floor (100) Sno (11 Roof (125) Wind (160) Ref. Single 2x Sizes LUS24 435 670 765 820 1,045 435 725 825 890 1,120 360 495 565 605 770 LUS26 1,165 865 990 1,070 1,355 1,165 935 1,070 1,150 1,475 865 635 725 785 1,000 MUS26 930 1,295 1,480 1,560 1,560 930 1,405 1,560 1,560 1,560 810 955 1,090 1,180 1,350 HUS26 1,320 2,735 3,095 3,235 3,235 1,320 2,960 3,280 3,280 3,280 1,150 2,350 2,660 2,780 2,780 HGUS26 1,040 4,355 4,875 5,230 5.390 1,045 4,725 5,295 5,390 5,390 1,005 3,755 4,205 4,495 5,390 LUS28 1,165 1,100 1,260 1,350 1,725 1,165 1,195 1,360 1,465 1,730 865 810 925 1,000 1,270 IBC, MUS28 1,320 1.730 1,975 2,125 2,255 1.320 1,875 2,135 2,255 2,255 1,150 1,270 1,455 1,575 1,955 FL, LA HUS28 1,760 4,095 4,095 4,095 4,095 1,760 4,095 4,095 4,095 4,095 1,480 3,520 3,520 3,520 3,520 HGUS28 1,650 7,275 7,275 7,275 7,275 1,650 7,275 7,275 7,275 7,275 1,485 6,010 6,255 6,255 6,255 LUS210 1,165 1,335 1,530 1,640 2,090 1,165 1,450 1,655 1,775 2,270 865 985 1,120 1,215 1,500 HUS210 2,635 5,450 5,795 5,830 5,830 2,635 5,395 5,780 5,830 5,830 2,220 4,685 4,985 5,015 5,015 HGUS210 2,090 9,100 9,100 9,100 9,100 2,090 9,100 9,100 9,100 9,100 1,545 6,340 6.730 6,730 6,730 1. For dimensions and fastener information, see table above. See table footnotes on p. 201. HHUS/HGUS See Hanger Options information on pp. 97-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers can be skewed to a maximum of 45° and/or sloped to a maximum of 45° • For skew only, maximum allowable download is 0.85 of the table load • For sloped only or sloped and skewed hangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb. • The joist must be bevel -cut to allow for double shear nailing HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45°. Allowable loads are HGUS Seat Width Joist Down Load Uplift W < 2" Square cut 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table load 0.46 of table load 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square cut 0.46 of table load 0.41 of table load W > 6" Bevel cut 0.85 of table load 0.41 of table load *__�cute side 0° 1 Specify angle Top View HHUS Hanger Skewed Right Foist must be bevel cut) All joist nails installed on the outside angle (non -acute side). 200