APPROVED BLD2022-0524+Architectural_Plan+4.27.2022_6.26.53_AM+2829638APPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
% .............................................
r
Interconnected Smoke Alarms Are A Requirement;
Of This Permit In Accordance With R314.2.2
.............................................
Building Permit Package
19115 Dellwood Drive
Edmonds, WA 98026
Ryan Buma / Buma Ventures
425.829.5524
Ryan.buma@gmail.com
19115 Dellwood Dr,
Edmonds, VGA 98026
18 min drive • ha -lie
CIN
. The following documentation shall be available on '
site for the building inspector:
Z COE APPROVED ARCHITECTURAL PLAN SET !
❑ COE APPROVED STRUCTURAL PLAN SET ;
COE REVIEWED CALCULATION PACKET
❑ ENERGY CREDIT WORKSHEET '.
❑ SITE PLAN
❑ CIVIL PLAN
!❑
:❑ ;
■ CITY OF EDMONDS BUILDING DEPARTMENT 2021
City Of Edmonds
Building Department
Work INTERIOR REMODEL
--------------------
Address 19115 DELLWOOD DR
Owner BUMA VENTURES
Approved Date ; 0 M /2022
Building Official ErU, Cafe r
---------------------------------
Permit Number; BLD2022-0524
--------------------------------------------
RECEIVED
Apr 28 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Project Scope & Description = Minor remodel of kitchen and bathrooms to modernize house built in the 1950's
Floor plan questions and responses:
1. Name and address of property owner and project contact person = 19115 Dellwood Drive, Edmonds, WA 98026. Ryan
Buma, 425.829.5524, ryan.buma@gmail.com
2. Dimension and specify use of each room and/or area; indicate the square footage of each floor = see enclosed layouts.
3. Specify size for doors and windows. Provide openable area and sill height of egress windows in all sleeping rooms = see
enclosed layouts; No changes planned for this area of the remodel.
4. Show extent of fire separation drywall between garage and living space and garage attic areas or habitable spaces over
garage = Garage walls and ceilings insulated and covered in 5/8" drywall; No changes planned for this area of the remodel.
5. Show required lighting for interior and exterior stairways = see enclosed pictures
6. Stairway and hallway widths, dimensions of stairs and guardrails = see enclosed layouts, guardrails are 30" off the floor, steel
construction. No changes planned for this area of the remodel.
7. Smoke and carbon monoxide alarm locations — see enclosed layouts with key of SD/CD for smoke & CO2 detector locations
8. Location, access, and clearance to crawl and attic spaces. Specify opening dimensions = as built, attic access size is 36" W by
42" L; entry in master closet; No crawl space; No changes planned for this area of the remodel.
9. Mechanical and plumbing fixtures/appliances; indicate type of heat = gas furnace, electric oven, electric cooktop, electric
hot water heater; No changes planned for type of heat and power for this remodel.
10. Direction, spacing, size and species of structural beams, joists, rafters and trusses = Stick frame construction, all floor and
ceiling joists run north/south. see enclosed Engineer specifications for areas impacted, only one new structural beam will
be added to open up the kitchen to the living and dining rooms, not other changes planned.
11. Distinguish new construction from existing; provide an existing and proposed floor plan (changes to existing only) = see
enclosed floorplans
RECEIVED
Apr 28 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
•
i---------------------- -- -- -- -- -- -- -- -- -- -- -- -- - -- --
i
Mechanical has not been
included in this review.
' ----------------------------------------------------
As built / existing upper -level floor plan
'G'!C-11 1I'T Or- M Y&" X5 I Z -' 1}'�'!' Cr d'-9 W a' -01a T S-1 11�'
See Calculation
Packet for structural
details
No d'+mge% to any exlt-mw boors or wrrdws. thew ~rill renmw m 4x sed.
Umn bears m - wndlh 77. hnUft 36 '. sd hm*d 42'
Bed roars 2 - wn dlh 7r. h l 36 ', .4 ray 4X
Sedmam a - widuh 77, 3, s* he•yhe42,
• Current upstairs floorplan
— 1958 split level, stick
framed construction.
• Measurements are
accurate to +- 1"
• The walls to be removed
are in yellow, the longer of
the two (orange arrow) is
load bearing and will be
re moved.
in Total span from existing
interior kitchen wall posts
is 14' requiring a new
IuLam to opern„gp the
space.
RECEIVED
Apr 28 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Proposed remodeled kitchen floorplan
19115 Dalkwood Drive. Edmond%. WA 980215
Propm&d & o - _ P s to emsmg fiborplan
H
21r-101W I 24' 4 112'
New proposed
kitchen floorplan
Total span from
existing interior
kitchen gall pasts
is 14" requiring a
new Glulam to
o.p!�n..up.the .space.
• See Engineers
Structural
Calculations later
in this packet.
RECEIVED
Apr 28 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
As built/ existing lower -level floor plan
Exisbn"
t T it taws' 1
rr
A`-„ Ur r 46 - .. - - . " r , Cr W.'r. 7 cs i*rj: , T T C e 14' ��3r , Lf Crff $ 3jdr .7 + -
s
hb aungm is any exlenor does ix wtwkwm. &w5c wil reRorr as PLrdqmmi
$drmn 4 - width Ar. hugf W. ,A twgt 42'
0
a Current lower -level
floorplan — 15
split level, stick
framed)
construction.
Garage galls and
ceilings insulated
and covered in
5 " drywall
RECEIVED
Apr 28 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Proposed remodeled laundry room floorplan
19115 Delllv= - - = • : q� Edmonds. % 9$02$
Propne S 10 exi5DnG Moo rplan
-, ' £ -
• Lower -level remodel
scope includes adding a
toiler and shower in the
existing laundry room
space.
• plumbing work will be
required, and a permit
will be applied for.
it Blain stack is less than
10' from new toilet, so
new drain will be short
with appropriate slope.
RECEIVED
Apr 28 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT